Sie sind auf Seite 1von 2

Tsunami QB-8100 Series

Quick Installation Guide


3. Now, wrap a layer of vinyl tape with the adhesive side out as it provides sticky surface for the next layer. 4. Next, wrap a layer of the butyl mastic tape on the adhesive side. 5. Finally, wrap vinyl tap over the butyl layer.

CAUTION! For regulatory information and latest product updates, including firmware and the MIBs, Proxim recommends you to visit its support site at http://support.proxim.com. IMPORTANT The device must be installed by a trained professional, value added reseller or systems integrator who is familiar with Radio Frequency planning issues and the regulatory limits.

Whats in the Kit


Quick Installation Guide

Image

Assemble the Mounting Hardware


Note: Tsunami QB-8100-LNK and QB-8150-LNK contains two sets of all the above accessories.
Fix the Mounting Plate (A) by using the provided screws and washers (Torque 9 N.m/75 inlbs) onto the bottom of the device such that the antennas will be vertically and horizontally polarized when mounted. Fix the Extension Arm (B) to the fixed mounting plate with the provided screw, nut and washers. The Extension Arm gives the device more possible tilt, letting you adjust for azimuth or elevation over a larger angle. Fix the Mounting Bracket (C) to fixed Extension Arm with the provided screw, nut and washers. Tighten the assembled parts (Torque 15 N.m/130 in-lbs). The last picture in Figure 3 shows the fully assembled mounting hardware attached to the device.

Introduction
Proxims Tsunami QuickBridge-8100 series point-to-point devices are designed to provide wireless networking solutions to enterprises and business markets. Two preconfigured bridges enable users to easily, quickly, and economically install a wireless LAN extension between two locations, eliminating the need for costly leased line or cable alternatives.

Device Overview

Products Covered in This Guide


Model
Tsunami QB-8100-EPA

Description
Outdoor QuickBridge End Point with 3 N-Type connectors, 300 Mbps, 3x3 MIMO, operating in 2.3 2.5 GHz or 4.9 6.0 GHz Bands. A pair of Tsunami QB-8100-EPA devices form a link. Outdoor QuickBridge End Point with Integrated Antennas, 300 Mbps, 2x2 MIMO, operating in 4.900 5.925 GHz Band. A pair of Tsunami QB-8150-EPR devices form a link.

QB-8150-EPR

QB-8100-EPA

Figure 1: Device Overview Note: While using connectorized devices, please ensure to use antenna port A1 for single polarization antennas, and antenna ports A1 and A3 for dual polarization antennas. Figure 3: Assemble the Mounting Hardware Note: This figure is for illustration only. Device should be mounted in square position with connectors facing downward.

Tsunami QB-8100-LNK Tsunami QB-8150-EPR

Weatherproofing RJ45 Connectors


The following steps explain how to weatherproof the RJ45 connectors: 1. Slide the Sealing Nut (E) over the bare end of the Cat5e/Cat6 cable. 2. Slide the tube-shaped Compression Washer (C) into the Compression Ring (D) and onto the Cat5e/Cat6 cable and tighten it into the Sealing Nut (E). 3. Insert the Flat Washer (A) into the Connector Body (B) to make it waterproof and screw the Connector Body into the Ethernet connector hole. 4. Terminate the RJ45 connectors on both ends of the Cat5e/Cat6 cable and test for proper wiring (cable should be a straight-through cable). 5. Slide the Cat5e/Cat6 cable through the screwed Ethernet Connector Body into the Ethernet jack inside the enclosure. The cable connector should latch into the jack. 6. Thread the assembled Sealing Nut onto the screwed Connector Body and hand tighten it to make a waterproof compression around the cable. 7. Open the notch on both sides of the Toroid and fix it on Ethernet Cat5e/Cat6 cable as shown in the figure. Then, lock the notch of the toroid by pressing it.

Mount the Device


1. To pole-mount the device, insert the provided screws through bracket (F). Fasten around the pole to bracket (C) and secure (Torque 11 N.m/100 in-lbs).

Tsunami QB-8150-LNK

Package Contents
Each shipment includes the items listed in the following table. Please verify that you have received all the parts in the shipment, prior to installation.

Figure 4: Pole Mounting


2. To wall-mount the device, mount the bracket to a wall using 4 screws (not provided).

Whats in the Kit


Tsunami QB-8100-EPA/ Tsunami QB-8150-EPR

Image
or QB-8100-EPA QB-8150-EPR

Power Injector and Power Cord PoE Surge Arrestor RJ11 to DB9 Serial Connector Grounding Kit

Figure 5: Wall Mounting

Note: To avoid electro magnetic emissions, please ensure to fix Toroid to the Ethernet cable.

Plug in the Cables


Note: Unscrew the sealing cap for installation of the cable.
1. Plug one end of the straight-through Cat5e/Cat6 cable into the Ethernet (RJ45) jack of the Ethernet 1 interface inside the enclosure. Plugging in the second Cat5e/Cat6 cable to Ethernet 2 interface is optional. Ensure that the cable connector is latched securely. You can hear a click sound when the cable connector latches into the jack, then tighten the sealing nut by hand. Connect the other end of the straight-through CAT5e/Cat6 cable (Ethernet 1) into the PWR LAN-OUT port on the PoE Injector.

Figure 2: Weatherproofing RJ45 Connector


Connector Weather Proofing Kit (2 sets) Mounting Kit and Hardware

Additional Weatherproofing Steps


To add an additional layer of protection to the connectors against the environment, do the following: 1. Wrap a vinyl tape in a half-lapped fashion, from the weatherproofed connector end and continue wrapping till 3 inches onto the cable. 2. Wrap a second layer of the vinyl tape over the first layer but in other direction.

EMI Toroids

Figure 6: Cable Plugged In


2. Optionally, connect a RJ11 to DB9 Serial Connector (supplied with the product package) to devices Serial Port for debugging and management.
3

Version 2.4 P/N 908-00002

Copyrights 2012 Proxim Wireless

Notes:
48 VDC (15 W average) is tolerable on the second Ethernet port (Ethernet 2). Make sure the connected device can support this voltage. If power from the second Ethernet Port (Ethernet 2) is desired, then Proxim recommends you to use 60W PoE (not supplied). If the device is connected to the second Ethernet port (Ethernet 2) for data, then use a PoE Splitter (not supplied).

5. Connect an RJ45 terminated cable between the two surge protectors on their remaining ports.

LED State

Ethernet 2
Power/Ethernet LED Wireless LED
Not Applicable Normal Operation Not Applicable Not Applicable Not Applicable Not Applicable No Power Power is on and the Ethernet link on Ethernet 2 is down Bootloader detected no image Power is on and the Ethernet link on Ethernet 2 is up

Ground the Device


To ensure proper grounding, use either of the ground points which are situated at the bottom corners of the device and the grounding screw provided to attach a ground wire of at least 10 AWG stranded to the device. It is important that the following ground guidelines are followed to protect the device against lighting or ESD events: 1. Connect one end of the grounding cable to the device as shown in the Figure 9 and the other end to the closest earthing system point at the installation. 2. Cut any extra ground wire length when finished connecting it to the single point earth ground. 3. Avoid sharp bends and never loop or coil up the ground wire, always connect it straight to ground. 4. A good earth ground impedance is less than 1.0 ohm. 5. Measure ground impedance at the point where the protector ground wire is connected and not at the ground rod. 6. Connect the protector ground wire and equipment ground (both power ground and telecomm ground) to a single common ground. 7. Make sure all connections are fastened securely and are tight. 8. Never install during a storm and always follow your local safety codes.
.

Yellow Off Blinking GreenFast Blinking GreenSlow Green

Figure 7: PoE Injector


3. To connect the device through a hub or a switch to a Personal Computer, connect an Ethernet cable between the network interface card in the Personal Computer and the hub, and between the hub and the RJ45 LAN-IN port on the PoE Injector. 4. To connect the device directly to a Personal Computer, connect an Ethernet cable between the network interface card in the Personal Computer and the RJ45 LANIN port on the PoE Injector.

Align the Antenna


The devices have an audible antenna alignment tool that can be activated by plugging in the serial dongle (supplied) or by using the CLI command for antenna alignment (refer to Antenna Alignment Commands in Tsunami MP-8000 Series Hardware Installation Guide available at http://support.proxim.com).

Connect the Antenna


Connect the antenna with N-male cables to the antenna connectors on the device.

Initialize the Device


You can configure the IP address of the device by using HTTP, CLI or SNMP and also using Proxims ScanTool. The following are the default configuration values to access the device: IP address: 169.254.128.132 Subnet Mask: 255.255.255.0 Gateway: 169.254.128.132 Username: admin Password: public SNMP Read Write Community String: public

Note: Record which port each antenna polarization is associated with to ensure that each side matches and aid in configuration.
Devices with integrated antennas must always be mounted in square position with all access ports pointed straight down to achieve horizontal and vertical polarization.

Figure 9: Grounding the Device

Install Surge Protector


Proxim recommends two approved lightning surge protectors to be installed, one near to the device and the other at the building ingress point.

Power on the Device


Plug in the power cord into a power outlet after having connected the PoE Injector and the device using straight-through Cat5e/Cat6 cable. There is no ON/OFF switch on the device. To disconnect power, unplug the RJ45 connector from the PWR LAN-OUT port on the PoE injector.

Note: To buy an additional Surge Protector (with Part Number: 235-00001), place an order separately with your distributor.
Perform the following steps to ensure proper surge protection: 1. Mount the provided surge protector near the outdoor device and use 10 AWG or larger wire to connect the protectors ground lug to the appropriate mounting ground point. The outdoor device and co-located surge protector should have a common grounding point using the shortest possible grounding cable. 2. Mount a second surge protector near the building ingress and use 10 AWG or larger wire to connect the surge protectors ground lug to earth ground as shown in figure 8.

Install the Documentation and Software


To download the Software and Documentation, please visit Proxims support site at http://support.proxim.com. Once you log on, select the product category Tsunami QB8100 Series from Product Downloads Page. In the Tsunami QB-8100 Series download and documentation page, links to the latest software, SNMP MIB file and documentation will be available for download.

View LEDs
When the device is powered on, it performs startup diagnostics. When startup is complete, the LEDs show the devices operational state. The LEDs are available at the devices Ethernet connector inside the enclosure. You can see the LEDs through the Ethernet connector. The LEDs will not be visible when the weather-sealing caps are installed. The following table describes the status of LEDs:

Note: You need Acrobat Reader to view the PDF documents.

Technical Support
Proxim eService Web site is available 7x24x365 at http://support.proxim.com Telephone Support: US and Canada: +1-408-383-7700; +1-866-674-6626 International: +1-408-383-7700; 0800-916475 (France); 8-800-100-9485 (Russia) Business Hours: 24x7 live response. Tier 3 support: 8 a.m. to 5 p.m. M-F PDT (UTC/ GMT -7 hrs)

LED State
Yellow Off

Ethernet 1
Power/Ethernet LED
Device is self heating (Cold Start) No Power Power is on and the Ethernet link on Ethernet 1 is down Bootloader detected no image Power is on and the Ethernet link on Ethernet 1 is up

Wireless LED
Power is on and the device detects Reload signal Radio is not present or failed to detect Radio is on and wireless link has not been established yet Not Applicable A wireless link has been established

Figure 8: Surge Protector Note: Use Outdoor-rated, UV protected, shielded Cat5e/Cat6 cable for the following.
3. Connect an RJ45 terminated cable between the indoor equipment and to the port on the surge protector at the building ingress. 4. Connect a short RJ45 terminated cable between the outdoor equipment and the port on the co-located surge protector. Blinking GreenFast Blinking GreenSlow Green

Proxim Wireless Corporation


1561 Buckeye Drive, Milpitas, California 95035 Phone: +1 408-383-7600 Fax: +1 408-383-7680

http://www.proxim.com 4 5 6

Das könnte Ihnen auch gefallen