Sie sind auf Seite 1von 40

COMPRESSORS

Collection of Datasheets

Compressors and Condensing Units for R290 (Propane) 220-240V 50Hz

R E F R I G E R AT I O N A N D A I R C O N D I T I O N I N G

R12 R22 R502

LBP/MBP Compressors
T-Series TL5CNK N-Series NL7CNK NL9CNK S-Series SC10CNX SC12CNX SC15CNX SC18CNX (50Hz) Page 10

LBP/MBP Condensing units


T-Series TL5CNK N-Series NL7CNK NL9CNK S-Series SC10CNX SC12CNX SC15CNX SC18CNX (50Hz) Page 24

(50Hz) (50Hz)

Page 12 Page 14

(50Hz) (50Hz)

Page 26 Page 28

(50Hz) (50Hz) (50Hz) (50Hz)

Page Page Page Page

16 18 20 22

(50Hz) (50Hz) (50Hz) (50Hz)

Page Page Page Page

30 32 34 36

CK.54.C1.02

September 2001

1. General

This collection of datasheets contains information on Danfoss hermetic refrigeration compressors and condensing units for 220-240V especially designed for refrigeration systems using propane, refrigerant R290 (C3H8). R290 is classified as a flammable refrigerant of class A3 according to ANSI/ASHRAE 34. Accordingly, special safety regulations must be complied with. For domestic appliances a special Test Schedule has been integrated in the European Standard EN 60335-2-24 and IEC 60335-2-24. For commercial refrigerators IEC 60335-2-89 will include flammable refrigerants. Danfoss compressors and condensing units for R290 must only and exclusively be used in appliances certified for R290 according to these or later regulations. This means that the compressors must not be used in appliances which are not originally designed and certified for R290. The programme consists of the basic types TL, NL and SC. The fan cooled condensing units for R290 are based on the TL, NL and SC compressors.

8238-3

8238-4

8238-6

TL 1.1 Designations

NL

SC

The compressor designations are built up according to the following system:


Design Optimization level Compressor size Application range Start characteristics

TL K = LST characteristics (capillary tube) X = HST characteristics (expansion valve)

NL

Blank Standard energy level

Nominal displacement in cm3

CN R290 LBP/MBP

SC

Examples

TL NL SC

5 7 12

CN CN CN

K K X

The condensing units designations are based on the compressor designations, extended by a version designation. For the time being, only N0 with solder connection, for capillary tube systems, is available. Example: SC12CNXN0

September 2001

CK.54.C1.02

1.2 Design

All compressors featured in this collection for R290 from the TL, NL and SC range are standard efficiency types.

1.3 Type label

TL5CNK
Application
220-240V~50Hz LBP/MBP HST

102H
R290

Barcode on white background Yellow background

DANFOSS COMPRESSORS

Compressors
Barcode Danfoss Version Barcode Code number

8416-2

Red stripe Approvals

4590

All compressors have a yellow label with the type designation. This label has a red stripe and the text R290. The country of origin indicated on the compressor paper label and on the compressor cover varies depending on the manufacturing place. Information can be found on our technical information sheet Country of Origin. All condensing units have a yellow type label located on the condenser and the packing. It gives the code number, model designation, rated voltage, frequency, refrigerant and a serial number.

TL5CNK
220-240V 50Hz Made in Ger many
Yellow background

114
R290 <150

F 1504

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8439

Condensing units

1.4 Data stamping

The compressor type and production date are stamped on the side of the compressor. The information may be as follows, L-5CN-4590 F-201E2207 The first line states the model designation and the code no. L = last letter (or last two letters) of the compressor type -5CN= nominal displacement and application 4590 = 4 last digits in the code no. (= position mark) The second line states the date of manufacture and internal Danfoss codes. F = manufacturing place (F = Germany, AL = Slovenia, AM = Mexico) 20 = week 20 1 = 2001 E = Friday (A = Monday etc.) 220 = nominal voltage 7 = internal Danfoss code

1.5 Dimensions

The build-in conditions (total height, weight, tube dimensions etc.) are specified in the individual datasheets including dimensioned sketches.

2. Application range CN

Compressors with denominations ending with CN are designed for low evaporating temperatures (LBP Low Back Pressure) and medium evaporating temperatures (MBP Medium Back Pressure) for use in commercial refrigerators, freezers and similar applications in regions with normal supply voltage. The following table shows the normally recommended applications as regards voltage/ frequency, ambient temperature, evaporating temperature and necessary compressor cooling. The recommendations must be regarded as a guideline only as they presuppose a proper dimensioning of the refrigeration system.

CK.54.C1.02

September 2001

Compressor
TL5NCK NL7CNK NL9CNK SC10-12-15-18CNK

Mains [V/Hz]
198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50

Ambient temperature 32C 38C 43C LBP MBP LBP MBP LBP MBP
F1 F1 F1 F2 F1 F1 F1 F2 F1 F1 F1 F2 F1 F1 F1 F2 F1 F1 F2 F2 F1* F2 F2* F2

CN

S O F1 F2 *

= = = = = =

Static cooling normally sufficient Oil cooling Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) Fan cooling 3.0 m/s necessary Outside application range, not recommended Run capacitor compulsory

The application limits regarding evaporating temperatures and motor systems are specified in the individual datasheets.

2.1 Design limits

Condensing temperature Winding temperature

In order to secure a satisfying lifetime of the compressor, and to protect the compressor against overload, some design criteria for the appliances must be fulfilled. Both the condensing temperature and the compressor temperature should be kept as low as possible. This can be done by using well-dimensioned condenser surfaces and by ensuring good ventilation around the compressor under all operating conditions. In order to protect the compressor against overload, the compressor has to start and work properly through pressure peaks obtained in the highest ambient temperature and lowest working voltage. At peak load the condensing temperature must not exceed 65C. The winding temperature must not exceed 135C. At stable operation conditions the condensing temperature must not exceed 55C. The winding temperature must not exceed 125C. These limitations ensure a protection of valves, gaskets, oil, and motor insulation. The condensing units are designed for 32C ambient temperature, but can also be used in 43C ambient. On some models 2 different condenser sizes are available, allowing for different application limits. Detailed information can be found in the individual datasheets. The compressors are equipped with a single-phase AC motor. All compressors for R290 are designed for use with Low Starting Torque (LST) or High Starting Torque (HST). The electrical equipments are classified as normal tight (IP20) The motor protector is built into the motor (winding protector). Earth connections are located on the bracket around the current lead-in of the compressor. No attempt must be made to start the compressor without a complete starting device. The compressors can be supplied with the following motor systems:

3. Electrical equipment

3.1 LST (RSIR)

Compressors with the motor type Resistant Start Induction Run (RSIR) have a starting device for Low Starting Torque (LST). This starting device consists of a PTC, a cord relief, and a cover and is used for compressors with the denominations TL and NL. The PTC starting device requires a pressure-equalization before each start. This starting device is normally used in well-designed refrigerating systems with capillary tube as throttling device. The PTC needs a compressor standstill period of 5 minutes to cool down before each start.

TL, NL

September 2001

CK.54.C1.02

8073

3.2 LST (RSCR)

TL, NL

8075

Compressors with the motor type Resistant Start Capacitor Run (RSCR) have a starting device for Low Starting Torque (LST). This starting device consists of a PTC and a run capacitor and is mandatory for compressors with the denominations TL and NL under certain conditions. The PTC starting device requires a pressureequalization before each start. This starting device is normally used in well-designed refrigerating systems with capillary tube as throttling device.

3.3 HST (CSR)

SC

Compressors with the motor type Capacitor Start Run (CSR) have a starting device for High Starting Torque (HST). This starting device consists of a starting relay, a starting capacitor, a run capacitor, a terminal board, a cord relief, and a cover. The starting device is mandatory for the SC compressors for R290. The starting capacitor is designed for short time cut-in. 1.7% ED, which is stamped on the starting capacitor, means for instance max. 10 cut-ins per hour each with a duration of 6 seconds. The starting device has to be placed where flammable concentrations of R290 in the air can not be reached, acc. to EN/IEC 60335-2-24, as it is to be considered as a possible igniton source. Delivery as a kit is possible also, see datasheets. For further information on which starting device to use on individual compressors, please refer to the actual datasheets.

8191

8414-3

SC Kit-version

3.4 Connections

The electrical equipments are equipped with connectors depending on the ordered code number, PTCs: 6.3 or 4.8 mm spade connectors and screws Connection boxes: 6.3 mm spade connectors and screws The power supply must be connected as shown in the wiring diagrams for the chosen electrical equipment given in the actual datasheets. Condensing units are equipped with connection boxes.

CK.54.C1.02

September 2001

3.5 Approvals

The compressors have been approved in respect of safety by testing authorities in the majority of Western European countries. Actual standards to which the compressors have been approved are specified in the individual datasheets. Approval markings appear on the compressor labels. To fulfil the requirements of EN 60355-2-34 the protection screen 103N0476 must be applied to the PTC starting device.

Protection screen

3.6 Condensing units

Fans are fitted with self-lubricating bearings and a large oil reservoir which ensures several years of operation without inspection. Except for the 5W and 10W fan, all motors have a built-in winding protector. The protectors are approved for the use with R290.

4. Moisture and Impurities

The compressors are dried to a maximum moisture content of 60 to 75 mg depending on the compressor size. The maximum impurity content is 40 to 50 mg depending on the compressor size.

5. Max. refrigerant charge

According to the European Standard EN 60335-2-24 or draft IEC 60335-2-89, which standard has to be complied with, the refrigerant charge must not exceed 150 g. Commercially available R290 must not be used because the fuel grades of these products are of a variable composition. These products may also contain impurities which could significantly reduce the reliability and performance of the system and lead to premature failure. All Danfoss compressors for R290 are released for a base purity of 99.5% or better. Impurities limits shall comply with DIN 8960 of 1998 (extended Version of ISO 916). For details see also separate documentation CN.60.F . All users of refrigerant R290 should refer to the chemical data safety sheets for full information on the safe handling of R290. In general the R290 charge is approximately 40 - 50% by weight than that for HFC. The refrigerant charge must never be too large to be contained on the condenser side of the refrigeration system. Only the refrigerant amount which is necessary for the system to function must be charged.

6. Oil charge

The compressors are supplied charged with dried and degassed oil, which is normally sufficient for the lifetime of the compressor. The refrigeration systems and the system components must be dimensioned in such a way that the oil can be lead back continuously to the compressor housing without accumulating in the system, e.g. without oil pockets and with sufficient gas velocity. The compressors use polyolester oils and are approved only for these oils and R290. The oil charge is specified in the individual datasheets.

September 2001

CK.54.C1.02

7363

7. Mounting

Soldering problems caused by oil in the connectors can be avoided by placing the compressor on its baseplate some time before soldering it into the system. The compressor must never be placed upside down when mounting the rubber grommets in the baseplate. Instead place the compressor on its side with the connectors upwards.

7.1 Mounting accessories


Washer Compressor base Nut M6 Grommet sleeve Washer Compressor base Clip Steel pin

3327-2

Cabinet base Cabinet base Screw M6 x 25 Rubber grommet

Rubber grommet

Bolt joint

Snap-on joint

The mounting accessories for the compressors are available in two versions, with bolt joint or snap-on joint. The rubber grommets are designed for the 16 mm holes of the baseplate. Bolt joint for one compressor in a bag 118-1917 Bolt joint in quantities 118-1918 Snap-on in quantities 118-1919

8. Condition at delivery

The compressors are delivered without mounted starting devices on pallets with the dimensions 1144 x 800 mm. Quantities per pallets are specified in the individual datasheets. Electrical equipment is packed in separate boxes. The most important performance controls carried out during manufacturing are, A high potential insulation test with 1650V for 1 second Pumping capacity Tightness of discharge side and discharge valve Tightness of compressor housing Check of the right oil charge Noise test The compressors are supplied with sealed connectors and the sealing should not be removed before the system assembly takes place (max 15 minutes with open connectors).

9. Conversion from R502/R22 or R404A/R507 to R290

Normally, the same system components can be used as were used with R22. However, an adjustment of the charge has to be made. Especially the system design has to follow safety standards as EN/IEC 60335-2-24 or IEC 60335-2-89, EN 378 or national standards. A drier with 3 desiccant of Molecular Sieves or a hard core drier compatible with R290 must always be used. Rules for dryness and cleanliness of system components (DIN 8964) are transferred to R290 systems. The compressors must be soldered into the system no later than 15 minutes after the connector seals have been removed. The same evacuation procedure as for R22/R502/R404A systems must be used. Max. 1% non-condensable gases. The system must not contain any chlorine.

CK.54.C1.02

September 2001

9
7382-2

10. Warnings

R290 is flammable in concentrations of air between approximately 2.1% and 9.5% by volume (LEL lower explosion limit and UEL upper explosion limit). An ignition source at a temperature higher than 470C is needed for a combustion to occur. No high potential test nor start tests must be carried out while the compressor is under vacuum. No attempt must be made to start the compressor without a complete starting device. Allow the compressor to assume a temperature above 10C before starting the first time in order Yellow warning label to avoid starting problems. Anti-freeze agents must not be used in the compressors as such agents are damaging to several of the materials used. In particular, the ethyl or methyl alcohol contents of such anti-freeze agents have a destructive effect on the synthetic motor insulation.

R290

September 2001

CK.54.C1.02

8122-3

TL5CNK LBP/MBP Compressor R290 (Propane) 220-240V 50Hz


Data Sheet (Replaces CH.52.A1.02) General
Compressor Code number TL5CNK 102H4590
Application

TL5CNK
R290
Red stripe Approvals

102H

Application
Application Evaporating temperature range C LBP/MBP LBP: -40 to -5 MBP: -20 to 5 Voltage range V/Hz LBP: 198 - 254 /50 MBP: 207 - 254 /50 Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C 38C 43C RSIR/RSCR* 43 F1 F1 F 1*

Yellow background

DANFOSS COMPRESSORS

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 F compulsory in 43C ambient temperature at MBP conditions

Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm3 cm
3

5.08 280 150 1690 7.5

R290
16

Yellow warning label

g cm3 kg

Motor
Motor size LRA (rated after 4 sec. UL984) LST Cut-in current LST watt A A 140 5.4 9.7 14.5/14.8 EN 60335-2-34
9 170 178 186 204 222 176

Resistance, main and start winding (25C) Approvals

35 70 100

C or D

or

D C E

Height

mm

A B

173 169 6.2 0.09 6.2 0.09 5.0 +0.12/+0.20 125

Suction connector Process connector Discharge connector Compressors on a pallet

location/I.D. mm location/I.D. mm location/I.D. mm pcs.

C D E

105

157 60.5 66

51 20

29 71

102

96 117

September 2001

CH.52.A2.02

105 107
8263

A B

30

Dimensions

8122-3

8416

Barcode on white background

4590

31.5 28

45

10

CK.54.C1.02

September 2001

Capacity (EN 12900/CECOMAF)


Comp.\C TL5CNK -40 81 -35 109 -30 143 -25 183 -23.3 198 -20 230 -15 283 -10 345 -5 416 0 496

watt
5 586
g

Capacity (ASHRAE)
Comp.\C TL5CNK -40 90 -35 122 -30 160 -25 204 -23.3 221 -20 256 -15 316 -10 386 -5 465 0 555

watt
5 657
b
8217

a1

Power consumption
Comp.\C TL5CNK -40 113 -35 130 -30 146 -25 162 -23.3 167 -20 178 -15 194 -10 211 -5 228 0 247

watt
5 266

d Main winding a1 Start winding


N

Current consumption
Comp.\C TL5CNK -40 1.00 -35 1.04 -30 1.09 -25 1.14 -23.3 1.16 -20 1.19 -15 1.25 -10 1.32 -5 1.39 0 1.46

A
5 1.54
N C L

COP (EN 12900/CECOMAF)


Comp.\C TL5CNK -40 0.71 -35 0.84 -30 0.98 -25 1.13 -23.3 1.18 -20 1.29 -15 1.46 -10 1.64 -5 1.82 0 2.01

W/W
5 2.21
(pos.1)
Winding protector

COP (ASHRAE)
Comp.\C TL5CNK -40 0.79 -35 0.94 -30 1.09 -25 1.26 -23.3 1.32 -20 1.44 -15 1.63 -10 1.83 -5 2.04 0 2.25

W/W
5 2.47
g e

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F1, 220V 50Hz

EN 12900/CECOMAF 45C 32C 45C

ASHRAE 45C 32C 32C

b
8223

a1 d e Main winding
N S

Accessories
Devices PTC starting device PTC starting device Cover Cord relief Run capacitor 4 F 6.3 mm spades 4.8 mm spades Protection screen for PTC Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities e g 117-7117* 117-7119* 103N0476 118-1917 118-1918 118-1919 Fig. 6.3 mm spades a1 4.8 mm spades (pos.1) 6.3 mm spades a1 4.8 mm spades (pos.2) b d TL5CNK 103N0011 103N0018 103N0016* 103N0021* 103N2010 103N1010
N C L

a1 Start winding

(pos.2)

Winding protector

* run capacitor 4 F compulsory in 43C ambient temperature at MBP conditions

CH.52.A2.02

September 2001

September 2001

CK.54.C1.02

11

NL7CNK LBP/MBP Compressor R290 (Propane) 220-240V 50Hz


Data Sheet General
Compressor Code number NL7CNK 105H6756
Application

NL7CNK
R290
Red stripe Approvals

105H

Application
Application Evaporating temperature range Voltage range Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C C V/Hz LBP/MBP -40 to 5 LBP: 198 - 254 /50 RSIR/RSCR 43 LBP: F1 MBP: F1 38C LBP: F1 MBP: F1 43C LBP: F1 MBP: F2

Yellow background

DANFOSS COMPRESSORS

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm
3

R290
7.27 320 150 2360
100 70

Yellow warning label

cm3 g cm3 kg

204 170

10.5

Motor
Motor size LRA (rated after 4 sec. UL984) LST Cut-in current LST watt A A 235 9.2 13.6 8.2/14.7
25

16 178

205

E C
35

Resistance, main and start winding (25C) Approvals

EN 60335-2-34
A B

102.5

Height

mm

A B

203 197 6.2 0.09 6.2 0.09 5.0 +0.12/+0.20


166

254
8248

Suction connector Process connector Discharge connector Compressors on a pallet

location/I.D. mm location/I.D. mm location/I.D. mm pcs.

C D E

80

60.5

72

47

113

119 127

May 2001

CH.53.A1.02

54 78

51

27

75.5

Dimensions

93.5

8122-3

8427

Barcode on white background

6756

15

12

CK.54.C1.02

September 2001

Capacity (EN 12900/CECOMAF)


Comp.\C NL7CNK -40 118 -35 166 -30 223 -25 290 -23.3 315 -20 368 -15 458 -10 561 -5 679 0 814

watt
5 965
g

Capacity (ASHRAE)
Comp.\C NL7CNK -40 131 -35 186 -30 249 -25 324 -23.3 352 -20 410 -15 511 -10 627 -5 760 0 910

watt
5 1081
b
8217

a1

Power consumption
Comp.\C NL7CNK -40 149 -35 174 -30 198 -25 221 -23.3 229 -20 244 -15 267 -10 291 -5 316 0 343

watt
5 372

d Main winding a1 Start winding


N

Current consumption
Comp.\C NL7CNK -40 1.40 -35 1.43 -30 1.48 -25 1.54 -23.3 1.56 -20 1.61 -15 1.69 -10 1.78 -5 1.89 0 2.00

A
5 2.13
N C L

COP (EN 12900/CECOMAF)


Comp.\C NL7CNK -40 0.79 -35 0.96 -30 1.13 -25 1.31 -23.3 1.38 -20 1.51 -15 1.71 -10 1.93 -5 2.15 0 2.37

W/W
5 2.59
(pos.1)
Winding protector

COP (ASHRAE)
Comp.\C NL7CNK -40 0.88 -35 1.07 -30 1.26 -25 1.46 -23.3 1.54 -20 1.68 -15 1.91 -10 2.16 -5 2.40 0 2.65

W/W
5 2.90
g e

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F1, 220V 50Hz, PTC consumption incl., preliminary data

EN 12900/CECOMAF 45C 32C 45C

ASHRAE 45C 32C 32C

b
8223

a1 d e Main winding
N S

Accessories
Devices PTC starting device PTC starting device Cover Cord relief Run capacitor 4 F (optional) 6.3 mm spades 4.8 mm spades Protection screen for PTC Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities e g 117-7117 117-7119 103N0476 118-1917 118-1918 118-1919 Fig. 6.3 mm spades a1 4.8 mm spades (pos.1) 6.3 mm spades a1 4.8 mm spades (pos.2) b d NL7CNK 103N0011 103N0018 103N0016 103N0021 103N2010 103N1010
N C L

a1 Start winding

(pos.2)

Winding protector

CH.53.A1.02

May 2001

September 2001

CK.54.C1.02

13

NL9CNK LBP/MBP Compressor R290 (Propane) 220-240V 50Hz


Data Sheet General
Compressor Code number NL9CNK 105H6856
Application

NL9CNK
R290
Red stripe Approvals

105H

Application
Application Evaporating temperature range C LBP/MBP LBP: -40 to -5 MBP: -20 to 5 Voltage range V/Hz LBP: 198 - 254 /50 MBP: 207 - 254 /50 Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C RSIR/RSCR* 43 LBP: F1 MBP: F1 38C LBP: F1 MBP: F1 43C LBP: F2 MBP: F2* * run capacitor 4 F compulsory in 43C ambient temperature at MBP conditions

Yellow background

DANFOSS COMPRESSORS

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

R290
204 170

Yellow warning label

Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm
3

8.35 320
100 70

cm3 g cm3 kg

150 2360 10.5

16 178

Motor
Motor size LRA (rated after 4 sec. UL984) LST Cut-in current LST watt A A 235 9.2

205

E C

25

13.6 8.2/14.7 EN 60335-2-34


A B
93.5

Resistance, main and start winding (25C) Approvals

102.5

Dimensions
Height mm A B Suction connector Process connector Discharge connector Compressors on a pallet location/I.D. mm location/I.D. mm location/I.D. mm pcs. C D E 203 197 6.2 0.09 6.2 0.09 5.0 +0.12/+0.20 80
113
60.5

254
8248

166

72

47

119 127

May 2001

CH.53.B1.02

54 78

51

27

75.5

8122-3

8427-2

Barcode on white background

6856

35
15

14

CK.54.C1.02

September 2001

Capacity (EN 12900/CECOMAF)


Comp.\C NL9CNK -40 138 -35 194 -30 259 -25 335 -23.3 364 -20 423 -15 526 -10 643 -5 778 0 930

watt
5 1102
g

Capacity (ASHRAE)
Comp.\C NL9CNK -40 153 -35 216 -30 289 -25 374 -23.3 406 -20 473 -15 587 -10 719 -5 869 0 1041

watt
5 1235
b
8217

a1

Power consumption
Comp.\C NL9CNK -40 169 -35 196 -30 223 -25 250 -23.3 259 -20 278 -15 306 -10 334 -5 364 0 395

watt
5 428

d Main winding a1 Start winding


N

Current consumption
Comp.\C NL9CNK -40 1.44 -35 1.50 -30 1.56 -25 1.64 -23.3 1.67 -20 1.73 -15 1.83 -10 1.95 -5 2.08 0 2.21

A
5 2.36
N C L

COP (EN 12900/CECOMAF)


Comp.\C NL9CNK -40 0.81 -35 0.99 -30 1.16 -25 1.34 -23.3 1.40 -20 1.53 -15 1.72 -10 1.92 -5 2.13 0 2.35

W/W
5 2.58
(pos.1)
Winding protector

COP (ASHRAE)
Comp.\C NL9CNK -40 0.91 -35 1.10 -30 1.29 -25 1.49 -23.3 1.56 -20 1.70 -15 1.92 -10 2.15 -5 2.39 0 2.63

W/W
5 2.89
g e

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F1, 220V 50Hz, PTC consumption incl., preliminary data

EN 12900/CECOMAF 45C 32C 45C

ASHRAE 45C 32C 32C

b
8223

a1 d e Main winding
N S

Accessories
Devices PTC starting device PTC starting device Cover Cord relief Run capacitor 4 F 6.3 mm spades 4.8 mm spades Protection screen for PTC Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities e g 117-7117* 117-7119* 103N0476 118-1917 118-1918 118-1919 Fig. 6.3 mm spades a1 4.8 mm spades (pos.1) 6.3 mm spades a1 4.8 mm spades (pos.2) b d NL9CNK 103N0011 103N0018 103N0016* 103N0021* 103N2010 103N1010
N C L

a1 Start winding

(pos.2)

Winding protector

* run capacitor 4 F compulsory in 43C ambient temperature at MBP conditions

CH.53.B1.02

May 2001

September 2001

CK.54.C1.02

15

SC10CNX LBP/MBP Compressor R290 (Propane) 220-240V 50Hz


Data Sheet (Replaces CH.54.A2.02) General
Compressor Code number SC10CNX 104H8065
Application

SC10CNX
R290
Red stripe Approvals

104H

Application
Application Evaporating temperature range Voltage range Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C 38C 43C C V/Hz LBP/MBP -40 to 5 198 - 254 /50 CSR 43 F2 F2 F2

Yellow background

DANFOSS COMPRESSORS

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm3 cm3 g cm
3

10.29 600 150 1410 13.1


16 204 178 170

R290
19 9.7

Yellow warning label

kg

Motor
127 101.6 35

LRA (rated after 4 sec. UL984) HST Cut-in current HST Resistance, main and start winding (25C) Approvals

A A

13.2 13.2 7.3/28.8 EN 60335-2-34

127 165 186 218

Dimensions
Height mm A B B1 B2 Suction connector Process connector Discharge connector Compressors on a pallet location/I.D. mm location/I.D. mm location/I.D. mm pcs. C D E 209 203 183 110 8.2 0.09 6.2 0.09 6.2 0.09 80
151 55 3
B1

E
B A B2

255

107

107 115

September 2001

CH.54.A3.02

55 63
8257

37

37

63

70 150

Motor size

watt

350

8122-3

8211

Barcode on white background

8065

16

CK.54.C1.02

September 2001

Capacity (EN 12900/CECOMAF)


Comp.\C SC10CNX -40 126 -35 179 -30 245 -25 325 -23.3 355 -20 420 -15 531 -10 660 -5 809 0 979

watt
5 1172

a3
a2 e

Capacity (ASHRAE)
Comp.\C SC10CNX -40 141 -35 200 -30 273 -25 362 -23.3 396 -20 468 -15 593 -10 738 -5 905 0 1096

watt
5 1312

c
8227

Power consumption
Comp.\C SC10CNX -40 174 -35 208 -30 242 -25 274 -23.3 285 -20 306 -15 335 -10 362 -5 386 0 406

watt
5 422

Current consumption
Comp.\C SC10CNX -40 1.12 -35 1.22 -30 1.33 -25 1.44 -23.3 1.48 -20 1.55 -15 1.66 -10 1.78 -5 1.89 0 2.00

A
5 2.12
b
Start winding
5 2

e a2
Bleeder resistance

COP (EN 12900/CECOMAF)


Comp.\C SC10CNX -40 0.72 -35 0.86 -30 1.01 -25 1.18 -23.3 1.25 -20 1.37 -15 1.58 -10 1.82 -5 2.10 0 2.41

W/W
5 2.77

Main winding Winding protector


1 2 N L 1 2 N L

COP (ASHRAE)
Comp.\C SC10CNX -40 0.81 -35 0.96 -30 1.13 -25 1.32 -23.3 1.39 -20 1.53 -15 1.77 -10 2.04 -5 2.35 0 2.70

W/W
5 3.11
M

a3
Fan

(pos.1)

Thermostat

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 45C 32C 45C

ASHRAE 45C 32C 32C

Connection cable

c e

Accessories
8414

Devices Starting device Starting device (kit) Cover Starting relay Starting capacitor Run capacitor Cord relief Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

Fig. a3
(pos.1)

SC10CNX 117-7011 (470 mm cable lenght) 117-7014 (1000 mm cable lenght) 117-9719 (1520 mm cable length) 103N2009 Components of starting device 103N1004 118-1917 118-1918 118-1919
Start winding
5 2

a2

(pos.2) b a2 c e d

e a2
Bleeder resistance

Main winding Winding protector


1 2 N L 1 2 N L

a3
M

Thermostat

Fan

(pos.2)

CH.54.A3.02

September 2001

September 2001

CK.54.C1.02

17

SC12CNX LBP/MBP Compressor R290 (Propane) 220-240V 50Hz


Data Sheet (Replaces CH.54.B2.02) General
Compressor Code number SC12CNX 104H8265
Application

SC12CNX
R290
Red stripe Approvals

104H

Application
Application Evaporating temperature range Voltage range Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C 38C 43C C V/Hz LBP/MBP -40 to 5 198 - 254 /50 CSR 43 F2 F2 F2

Yellow background

DANFOSS COMPRESSORS

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm3 cm3 g cm
3

12.87 600 150 1410 13.1


16 204 178 170

R290
19 9.7

Yellow warning label

kg

Motor
127 101.6 35

LRA (rated after 4 sec. UL984) HST Cut-in current HST Resistance, main and start winding (25C) Approvals

A A

13.2 13.2 7.3/28.8 EN 60335-2-34

127 165 186 218

Dimensions
Height mm A B B1 B2 Suction connector Process connector Discharge connector Compressors on a pallet location/I.D. mm location/I.D. mm location/I.D. mm pcs. C D E 209 203 183 110 8.2 0.09 6.2 0.09 6.2 0.09 80
151 55 3
B1

E
B A B2

255

107

107 115

September 2001

CH.54.B3.02

55 63
8257

37

37

63

70 150

Motor size

watt

350

8122-3

8211-2

Barcode on white background

8265

18

CK.54.C1.02

September 2001

Capacity (EN 12900/CECOMAF)


Comp.\C SC12CNX -40 178 -35 250 -30 331 -25 426 -23.3 462 -20 540 -15 678 -10 846 -5 1050 0 1293

watt
5 1582

a3
a2 e

Capacity (ASHRAE)
Comp.\C SC12CNX -40 199 -35 279 -30 369 -25 475 -23.3 516 -20 603 -15 757 -10 946 -5 1174 0 1447

watt
5 1772

c
8227

Power consumption
Comp.\C SC12CNX -40 230 -35 269 -30 307 -25 344 -23.3 356 -20 381 -15 418 -10 456 -5 494 0 535

watt
5 576

Current consumption
Comp.\C SC12CNX -40 1.28 -35 1.44 -30 1.60 -25 1.76 -23.3 1.81 -20 1.92 -15 2.09 -10 2.27 -5 2.45 0 2.63

A
5 2.81
b
Start winding
5 2

e a2
Bleeder resistance

COP (EN 12900/CECOMAF)


Comp.\C SC12CNX -40 0.77 -35 0.93 -30 1.08 -25 1.24 -23.3 1.30 -20 1.42 -15 1.62 -10 1.86 -5 2.12 0 2.42

W/W
5 2.74

Main winding Winding protector


1 2 N L 1 2 N L

COP (ASHRAE)
Comp.\C SC12CNX -40 0.86 -35 1.04 -30 1.21 -25 1.38 -23.3 1.45 -20 1.58 -15 1.81 -10 2.08 -5 2.37 0 2.71

W/W
5 3.07
M

a3
Fan

(pos.1)

Thermostat

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 45C 32C 45C

ASHRAE 45C 32C 32C

Connection cable

c e

Accessories
8414

Devices Starting device Starting device (kit) Cover Starting relay Starting capacitor Run capacitor Cord relief Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

Fig. a3
(pos.1)

SC12CNX 117-7011 (470 mm cable lenght) 117-7014 (1000 mm cable lenght) 117-9719 (1520 mm cable length) 103N2009 Components of starting device 103N1004 118-1917 118-1918 118-1919
Start winding
5 2

a2

(pos.2) b a2 c e d

e a2
Bleeder resistance

Main winding Winding protector


1 2 N L 1 2 N L

a3
M

Thermostat

Fan

(pos.2)

CH.54.B3.02

September 2001

September 2001

CK.54.C1.02

19

SC15CNX LBP/MBP Compressor R290 (Propane) 220-240V 50Hz


Data Sheet (Replaces CH.54.C2.02) General
Compressor Code number SC15CNX 104H8565
Application

SC15CNX
R290
Red stripe Approvals

104H

Application
Application Evaporating temperature range Voltage range Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C 38C 43C C V/Hz LBP/MBP -40 to 5 198 - 254 /50 CSR 43 F2 F2 F2

Yellow background

DANFOSS COMPRESSORS

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm3 cm3 g cm
3

15.28 600 150 1410 13.1


16 204 178 170

R290
19 9.7

Yellow warning label

kg

Motor
127 101.6 35

LRA (rated after 4 sec. UL984) HST Cut-in current HST Resistance, main and start winding (25C) Approvals

A A

14.8 14.8 5.0/13.7 EN 60335-2-34

127 165 186 218

Dimensions
Height mm A B B1 B2 Suction connector Process connector Discharge connector Compressors on a pallet location/I.D. mm location/I.D. mm location/I.D. mm pcs. C D E 209 203 183 110 8.2 0.09 6.2 0.09 6.2 0.09 80
151 55 3
B1

E
B A B2

255

107

107 115

September 2001

CH.54.C3.02

55 63
8257

37

37

63

70 150

Motor size

watt

385

8122-3

8211-3

Barcode on white background

8565

20

CK.54.C1.02

September 2001

Capacity (EN 12900/CECOMAF)


Comp.\C SC15CNX -40 195 -35 297 -30 415 -25 550 -23.3 601 -20 707 -15 887 -10 1093 -5 1328 0 1594

watt
5 1894

a3
a2 e

Capacity (ASHRAE)
Comp.\C SC15CNX -40 217 -35 331 -30 462 -25 614 -23.3 671 -20 789 -15 991 -10 -5 1221 1485

watt
0 5 1784 2122

c
8227

Power consumption
Comp.\C SC15CNX -40 256 -35 315 -30 370 -25 420 -23.3 436 -20 467 -15 514 -10 560 -5 608 0 659

watt
5 715

Current consumption
Comp.\C SC15CNX -40 1.28 -35 1.55 -30 1.82 -25 2.08 -23.3 2.17 -20 2.33 -15 2.58 -10 2.82 -5 3.05 0 3.27

A
5 3.49
b
Start winding
5 2

e a2
Bleeder resistance

COP (EN 12900/CECOMAF)


Comp.\C SC15CNX -40 0.76 -35 0.94 -30 1.12 -25 1.31 -23.3 1.38 -20 1.51 -15 1.73 -10 1.95 -5 2.18 0 2.42

W/W
5 2.65

Main winding Winding protector


1 2 N L 1 2 N L

COP (ASHRAE)
Comp.\C SC15CNX -40 0.85 -35 1.05 -30 1.25 -25 1.46 -23.3 1.54 -20 1.69 -15 1.93 -10 2.18 -5 2.44 0 2.71

W/W
5 2.97
M

a3
Fan

(pos.1)

Thermostat

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 45C 32C 45C

ASHRAE 45C 32C 32C

Connection cable

c e

Accessories
8414

Devices Starting device Starting device (kit) Cover Starting relay Starting capacitor Run capacitor Cord relief Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

Fig. a3
(pos.1)

SC15CNX 117-7012 (470 mm cable lenght) 117-9711 (1020 mm cable length) 103N2009 Components of starting device 103N1004 118-1917 118-1918 118-1919
Start winding
5 2

a2

(pos.2) b a2 c e d

e a2
Bleeder resistance

Main winding Winding protector


1 2 N L 1 2 N L

a3
M

Thermostat

Fan

(pos.2)

CH.54.C3.02

September 2001

September 2001

CK.54.C1.02

21

SC18CNX LBP/MBP Compressor R290 (Propane) 220-240V 50Hz


Data Sheet (Replaces CH.54.D2.02) General
Compressor Code number SC18CNX 104H8865
Application

SC18CNX
R290
Red stripe Approvals

104H

Application
Application Evaporating temperature range Voltage range Motor type Max. ambient temperature Comp. cooling at ambient temp. C 32C 38C 43C C V/Hz LBP/MBP -40 to 5 198 - 254 /50 CSR 43 F2 F2 F2

Yellow background

DANFOSS COMPRESSORS

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design
Displacement Oil quantity Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment cm3 cm3 g cm
3

17.69 600 150 1460 13.5


16 204 178 170

R290
19 9.7

Yellow warning label

kg

Motor
127 101.6 35

LRA (rated after 4 sec. UL984) HST Cut-in current HST Resistance, main and start winding (25C) Approvals

A A

19.5 19.5 4.6/17.8 EN 60335-2-34

127 165 186 218

Dimensions
Height mm A B B1 B2 Suction connector Process connector Discharge connector Compressors on a pallet location/I.D. mm location/I.D. mm location/I.D. mm pcs. C D E 219 213 193 100 10.2 0.09 6.2 0.09 6.2 0.09 80
151 55 3
B1

E
B A B2

255

107

107 115

September 2001

CH.54.D3.02

55 63
8257

37

37

63

70 150

Motor size

watt

540

8122-3

8211-4

Barcode on white background

8865

22

CK.54.C1.02

September 2001

Capacity (EN 12900/CECOMAF)


Comp.\C SC18CNX -40 219 -35 341 -30 480 -25 640 -23.3 700 -20 824 -15 1033 -10 1272 -5 1543

watt
0 5 1849 2193

a3
a2 e

Capacity (ASHRAE)
Comp.\C SC18CNX -40 244 -35 380 -30 535 -25 714 -23.3 781 -20 919 -15 1154 -10 1422 -5 0 1726 2070

watt
5 2456

c
8227

Power consumption
Comp.\C SC18CNX -40 304 -35 370 -30 435 -25 500 -23.3 522 -20 566 -15 635 -10 707 -5 783 0 864

watt
5 952

Current consumption
Comp.\C SC18CNX -40 1.80 -35 2.08 -30 2.34 -25 2.60 -23.3 2.68 -20 2.85 -15 3.09 -10 3.32 -5 3.54 0 3.76

A
5 3.97
b
Start winding
5 2

e a2
Bleeder resistance

COP (EN 12900/CECOMAF)


Comp.\C SC18CNX -40 0.72 -35 0.92 -30 1.10 -25 1.28 -23.3 1.34 -20 1.45 -15 1.63 -10 1.80 -5 1.97 0 2.14

W/W
5 2.30

Main winding Winding protector


1 2 N L 1 2 N L

COP (ASHRAE)
Comp.\C SC18CNX -40 0.80 -35 1.03 -30 1.23 -25 1.43 -23.3 1.49 -20 1.62 -15 1.82 -10 2.01 -5 2.20 0 2.39

W/W
5 2.58
M

a3
Fan

(pos.1)

Thermostat

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 45C 32C 45C

ASHRAE 45C 32C 32C

Connection cable

c e

Accessories
8414

Devices Starting device Starting device (kit) Cover Starting relay Starting capacitor Run capacitor Cord relief Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

Fig. a3
(pos.1)

SC18CNX 117-7034 (470 mm cable lenght 117-9718 (1020 mm cable length) 103N2009 Components of starting device 103N1004 118-1917 118-1918 118-1919
Start winding
5 2

a2

(pos.2) b a2 c e d

e a2
Bleeder resistance

Main winding Winding protector


1 2 N L 1 2 N L

a3
M

Thermostat

Fan

(pos.2)

CH.54.D3.02

September 2001

September 2001

CK.54.C1.02

23

TL5CNK LBP/MBP Condensing Unit R290 (Propane) 220-240V 50Hz


Data Sheet General
Barcode Danfoss Version Barcode Code number

Condensing unit Version N0 - for capillary tube Size BG1

TL5CNK Code number 114F1504

TL5CNK
R290 Made in Ger many
Yellow background

114

F 1504

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8439

Application
Application Evaporating temperature range at 32C at 43C Voltage range Maximum refrigerant charge R290 C C V/Hz g LBP/MBP -40 to 5 -40 to -20 198 - 254 /50 150

Flammable Refrigerant:
Unit must only be installed and serviced by authorized personnel (see instructions "Fan-cooled Condensing Units 220-240V for R290", CI.34.C).

R290

Yellow warning label

Packing data
Net weight Gross weight Package height Package width Package depth kg kg mm mm mm 11.3 13.5 245 400 530

Dimensions
Height (H) Width (W) Depth (D) Distance (a) Suction connecton Liquid connection Process connecton mm mm mm mm I.D. mm I.D. mm I.D. mm 198 267 410 310 6.2 6.5 6.2

310 D
drawing shows N0 version

8.5 8 x 7
8440

September 2001

CD.32.C1.02

192 228

24

CK.54.C1.02

September 2001

8122-3

Capacity (EN 13215/CECOMAF)


Evap. temp in C TL5CNK -BG1 -45 -40 93 -35 120 -30 152 -25 188 -23.3 199 -20 229 -15 273 -10 320 -5 370 0 421 5 474 10

watt
15

Power consumption
Evap. temp in C TL5CNK -BG1 -45 -40 141 -35 156 -30 171 -25 188 -23.3 194 -20 205 -15 225 -10 246 -5 269 0 295 5 323 10

watt
15

Current consumption
Evap. temp in C TL5CNK -BG1 -45 -40 1.20 -35 1.23 -30 1.27 -25 1.32 -23.3 1.35 -20 1.39 -15 1.46 -10 1.54 -5 1.63 0 1.73 5 1.85 10 15

Capacity (DIN 8971)


Evap. temp in C TL5CNK -BG1 -45 -40 90 -35 116 -30 147 -25 182 -23.3 192 -20 221 -15 263 -10 309 -5 357 0 406 5 457 10

watt
15

Test conditions (220V 50Hz) EN 13215/CECOMAF DIN 8971 Ambient temperature 32C 32C Suction gas temperature 32C 25C Temperature of refrigerant at condenser outlet is subcooled within the condensing limits of the unit. 1 Watt = 0.86 kcal/h, 1 Watt = 3.41 Btu/h

Spareparts
Devices Size Condenser Fancowl Fanblade Fanmotor 114F1504 BG1 118U0100 118U0401 117-3819 ( 170 mm) 118U0200 (5W)

Wiring diagram
Fig. Devices A B C D F e 1 2 3 4 5 6 7 Compressor Electrical equipment (PTC) Connection box Fan motor Thermostat Run capacitor (optional) Black wire Blue wire Brown wire Green-yellow wire Main Winding Start Winding Winding Protector
1 2 N L 1 2 N L 3 4 2 1 2 1 3

N
B

S
6

8449

CD.32.C1.02

September 2001

September 2001

CK.54.C1.02

25

NL7CNK LBP/MBP Condensing Unit R290 (Propane) 220-240V 50Hz


Data Sheet General
Barcode Danfoss Version Barcode Code number

Condensing unit Version N0 - for capillary tube Size BG2

NL7CNK Code number 114F2505

NL7CNK
R290 Made in Ger many
Yellow background

114

F 2505

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8450

Application
Application Evaporating temperature range at 32C at 43C Voltage range Maximum refrigerant charge R290 C C V/Hz g LBP/MBP -40 to 5 -40 to -15 198 - 254 /50 150

Flammable Refrigerant:
Unit must only be installed and serviced by authorized personnel (see instructions "Fan-cooled Condensing Units 220-240V for R290", CI.34.C).

R290

Yellow warning label

Packing data
Net weight Gross weight Package height Package width Package depth kg kg mm mm mm 18 19 245 400 530

Dimensions
Height (H) Width (W) Depth (D) Distance (a) Suction connecton Liquid connection Process connecton mm mm mm mm I.D. mm I.D. mm I.D. mm 225 298 432 310 6.2 6.5 6.2

310 D
drawing shows N0 version

8.5

September 2001

CD.33.B1.02

192 228

8 x 7
8441

26

CK.54.C1.02

September 2001

8122-3

Capacity (EN 13215/CECOMAF)


Evap. temp in C NL7CNK -BG2 -45 -40 141 -35 188 -30 243 -25 305 -23.3 327 -20 373 -15 449 -10 531 -5 619 0 712 5 808 10

watt
15

Power consumption
Evap. temp in C NL7CNK -BG2 -45 -40 178 -35 201 -30 223 -25 246 -23.3 254 -20 270 -15 296 -10 325 -5 357 0 394 5 436 10

watt
15

Current consumption
Evap. temp in C NL7CNK -BG2 -45 -40 1.63 -35 1.65 -30 1.68 -25 1.73 -23.3 1.75 -20 1.80 -15 1.89 -10 1.99 -5 2.13 0 2.28 5 2.46 10 15

Capacity (DIN 8971)


Evap. temp in C NL7CNK -BG2 -45 -40 136 -35 182 -30 235 -25 294 -23.3 316 -20 361 -15 434 -10 513 -5 597 0 686 5 779 10

watt
15

Test conditions (220V 50Hz) EN 13215/CECOMAF DIN 8971 Ambient temperature 32C 32C Suction gas temperature 32C 25C Temperature of refrigerant at condenser outlet is subcooled within the condensing limits of the unit. 1 Watt = 0.86 kcal/h, 1 Watt = 3.41 Btu/h

Spareparts
Devices Size Condenser Fancowl Fanblade Fanmotor 114F2505 BG2 118U0101 118U0402 117-3814 ( 200 mm) 118U0200 (5W)

Wiring diagram
Fig. Devices A B C D F e 1 2 3 4 5 6 7 Compressor Electrical equipment (PTC) Connection box Fan motor Thermostat Run capacitor (optional) Black wire Blue wire Brown wire Green-yellow wire Main Winding Start Winding Winding Protector
1 2 N L 1 2 N L 3 4 2 1 2 1 3

N
B

S
6

8449

CD.33.B1.02

September 2001

September 2001

CK.54.C1.02

27

NL9CNK LBP/MBP Condensing Unit R290 (Propane) 220-240V 50Hz


Data Sheet General
Barcode Danfoss Version Barcode Code number

Condensing unit Version N0 - for capillary tube Size BG2

NL9CNK Code number 114F2506

NL9CNK
R290 Made in Ger many
Yellow background

114

F 2506

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8450-2

Application
Application Evaporating temperature range at 32C at 43C Voltage range Maximum refrigerant charge R290 C C V/Hz g LBP/MBP -40 to 0 -40 to -15 198 - 254 /50 150

Flammable Refrigerant:
Unit must only be installed and serviced by authorized personnel (see instructions "Fan-cooled Condensing Units 220-240V for R290", CI.34.C).

R290

Yellow warning label

Packing data
Net weight Gross weight Package height Package width Package depth kg kg mm mm mm 18 19 245 400 530

Dimensions
Height (H) Width (W) Depth (D) Distance (a) Suction connecton Liquid connection Process connecton mm mm mm mm I.D. mm I.D. mm I.D. mm 225 298 432 310 6.2 6.5 6.2

310 D
drawing shows N0 version

8.5

September 2001

CD.33.C1.02

192 228

8 x 7
8441

28

CK.54.C1.02

September 2001

8122-3

Capacity (EN 13215/CECOMAF)


Evap. temp in C NL9CNK -BG2 -45 -40 161 -35 214 -30 275 -25 343 -23.3 368 -20 419 -15 500 -10 588 -5 680 0 775 5 10

watt
15

Power consumption
Evap. temp in C NL9CNK -BG2 -45 -40 196 -35 222 -30 248 -25 276 -23.3 286 -20 305 -15 338 -10 374 -5 415 0 460 5 10

watt
15

Current consumption
Evap. temp in C NL9CNK -BG2 -45 -40 1.66 -35 1.70 -30 1.75 -25 1.83 -23.3 1.86 -20 1.93 -15 2.05 -10 2.19 -5 2.36 0 2.56 5 10 15

Capacity (DIN 8971)


Evap. temp in C NL9CNK -BG2 -45 -40 155 -35 207 -30 266 -25 332 -23.3 356 -20 404 -15 483 -10 567 -5 656 0 748 5 10

watt
15

Test conditions (220V 50Hz) EN 13215/CECOMAF DIN 8971 Ambient temperature 32C 32C Suction gas temperature 32C 25C Temperature of refrigerant at condenser outlet is subcooled within the condensing limits of the unit. 1 Watt = 0.86 kcal/h, 1 Watt = 3.41 Btu/h

Spareparts
Devices Size Condenser Fancowl Fanblade Fanmotor 114F2506 BG2 118U0101 118U0402 117-3814 ( 200 mm) 118U0200 (5W)

Wiring diagram
Fig. Devices A B C D F e 1 2 3 4 5 6 7 Compressor Electrical equipment (PTC) Connection box Fan motor Thermostat Run capacitor (optional) Black wire Blue wire Brown wire Green-yellow wire Main Winding Start Winding Winding Protector
1 2 N L 1 2 N L 3 4 2 1 2 1 3

N
B

S
6

8449

CD.33.C1.02

September 2001

September 2001

CK.54.C1.02

29

SC10CNX LBP/MBP Condensing Unit R290 (Propane) 220-240V 50Hz


Data Sheet (Replaces CD.34.A2.02) General
Barcode Danfoss Version Barcode Code number

Condensing unit Version N0 - for capillary tube N0 - for capillary tube Size BG2 BG3

SC10CNX Code number 114F2500 114F3500

SC10CNX
R290 Made in Ger many
Yellow background

114

F 2500

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8438

Application
Application Evaporating temperature range at 32C C LBP/MBP BG2: -40 to 0 BG3: -40 to 5 at 43C C BG2: -40 to -20 BG3: -40 to -10 Voltage range Maximum refrigerant charge R290 V/Hz g 198 - 254 /50 150

Flammable Refrigerant:
Unit must only be installed and serviced by authorized personnel (see instructions "Fan-cooled Condensing Units 220-240V for R290", CI.34.C).

R290

Yellow warning label

Packing data
Net weight Gross weight Package height Package width Package depth kg kg mm mm mm

114F2500
17.8 19.8 245 400 530

114F3500
18.8 20.8 275 400 530

Dimensions
Height (H) Width (W) Depth (D) Distance (a) Suction connecton Liquid connection Process connecton mm mm mm mm I.D. mm I.D. mm I.D. mm

114F2500
225 285 432 310 8.2 6.5 6.2

114F3500
257 310 444 325 8.2 6.5 6.2

325 D
drawing shows N0 version

8.5

September 2001

CD.34.A3.02

192

8 x 7
8437

228
1

30

CK.54.C1.02

September 2001

8122-3

Capacity (EN 13215/CECOMAF)


Evap. temp in C SC10CNX -BG2 SC10CNX -BG3 Evap. temp in C SC10CNX -BG2 SC10CNX -BG3
Evap. temp in C SC10CNX -BG2 SC10CNX -BG3

watt
-35 204 217 -35 240 251
-35 1.42 1.48

-45

-40 153 162 -40 210 222


-40 1.33 1.39

-30 263 282 -30 270 280


-30 1.52 1.57

-25 333 358 -25 301 309


-25 1.63 1.67

-23.3 358 386 -23.3 312 319


-23.3 1.67 1.70

-20 411 445 -20 333 339


-20 1.75 1.78

-15 499 545 -15 366 369


-15 1.88 1.90

-10 596 656 -10 400 399


-10 2.03 2.03

-5 701 778 -5 434 429


-5 2.19 2.18

0 814 913 0 469 460


0 2.37 2.33

5 1058

10

15

Power consumption
-45 5 491 10

watt
15

Current consumption
-45 5 2.50 10 15

Capacity (DIN 8971)


Evap. temp in C SC10CNX -BG2 SC10CNX -BG3 -45 -40 148 157 -35 197 210 -30 255 272 -25 322 346 -23.3 346 373 -20 398 430 -15 482 526 -10 575 632 -5 676 750 0 784 879 5 1018 10

watt
15

Test conditions (220V 50Hz) EN 13215/CECOMAF DIN 8971 Ambient temperature 32C 32C Suction gas temperature 32C 25C Temperature of refrigerant at condenser outlet is subcooled within the condensing limits of the unit. 1 Watt = 0.86 kcal/h, 1 Watt = 3.41 Btu/h

Spareparts
Devices Size Condenser Fancowl Fanblade Fanmotor 114F2500 BG2 118U0101 118U0402 117-3814 ( 200 mm) 118U0200 (5W) 114F3500 BG3 118U0102 118U0403 118U0600 ( 230 mm) 118U0201(11W)

Wiring diagram
Fig. Devices A B C D E F 1 2 3 4 5 6 7 Compressor
8212

Danfoss electrical equipment Extra connection box Fan motor Pressure switch Thermostat Black wire Blue wire Brown wire

4 3 2 1

B
1 2 N L 1 2 N L 4 1 5 2

A
M
5

Green-yellow wire
7

Main Winding Start Winding Winding Protector

C
1 2 N L 1 2 1 2 N L 3

CD.34.A3.02

September 2001

September 2001

CK.54.C1.02

31

SC12CNX LBP/MBP Condensing Unit R290 (Propane) 220-240V 50Hz


Data Sheet General
Barcode Danfoss Version Barcode Code number

Condensing unit Version N0 - for capillary tube N0 - for capillary tube Size BG3 BG4

SC12CNX Code number 114F3501 114F4501

SC12CNX
R290 Made in Ger many
Yellow background

114

F 3501

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8438-2

Application
Application Evaporating temperature range at 32C at 43C C C LBP/MBP -40 to 5 BG3: -40 to -10 BG4: -40 to -5 Voltage range Maximum refrigerant charge R290 V/Hz g 198 - 254 /50 150

Flammable Refrigerant:
Unit must only be installed and serviced by authorized personnel (see instructions "Fan-cooled Condensing Units 220-240V for R290", CI.34.C).

R290

Yellow warning label

Packing data
Net weight Gross weight Package height Package width Package depth kg kg mm mm mm

114F3501
18.8 20.8 275 400 530

114F4501
20.6 22.6 320 400 590

Dimensions
Height (H) Width (W) Depth (D) Distance (a) Suction connecton Liquid connection Process connecton mm mm mm mm I.D. mm I.D. mm I.D. mm

114F3501
256 310 444 325 8.2 6.5 6.2

114F4501
296 330 451 325 8.2 6.5 6.2

325 D
drawing shows N0 version

8.5

September 2001

CD.34.E1.02

192

8 x 7
8437

228
1

32

CK.54.C1.02

September 2001

8122-3

Capacity (EN 13215/CECOMAF)


Evap. temp in C SC12CNX -BG3 SC12CNX -BG4 Evap. temp in C SC12CNX -BG3 SC12CNX -BG4
Evap. temp in C SC12CNX -BG3 SC12CNX -BG4

watt
-35 284 292 -35 304 321
-35 1.69 1.83

-45

-40 219 225 -40 271 289


-40 1.56 1.71

-30 358 369 -30 339 354


-30 1.83 1.96

-25 446 462 -25 375 389


-25 1.99 2.11

-23.3 479 497 -23.3 388 401


-23.3 2.05 2.16

-20 547 571 -20 415 426


-20 2.17 2.27

-15 665 698 -15 458 467


-15 2.36 2.46

-10 799 846 -10 505 511


-10 2.58 2.66

-5 949 1014 -5 557 560


-5 2.83 2.88

0 1116 1202 0 614 613


0 3.10 3.14

5 1298 1410 5 678 673


5 3.41 3.42

10

15

Power consumption
-45 10

watt
15

Current consumption
-45 10 15

Capacity (DIN 8971)


Evap. temp in C SC12CNX -BG3 SC12CNX -BG4 -45 -40 212 218 -35 274 282 -30 346 357 -25 431 446 -23.3 462 480 -20 529 551 -15 642 674 -10 771 816 -5 915 978 0 1075 1158 5 1249 1358 10

watt
15

Test conditions (220V 50Hz) EN 13215/CECOMAF DIN 8971 Ambient temperature 32C 32C Suction gas temperature 32C 25C Temperature of refrigerant at condenser outlet is subcooled within the condensing limits of the unit. 1 Watt = 0.86 kcal/h, 1 Watt = 3.41 Btu/h

Spareparts
Devices Size Condenser Fancowl Fanblade Fanmotor 114F3501 BG3 118U0102 118U0403 118U0600 ( 230 mm) 118U0201 (11W) 114F4501 BG4 118U0103 118U0404 118U0601 ( 254 mm) 118U0202 (16W)

Wiring diagram
Fig. Devices A B C D E F 1 2 3 4 5 6 7 Compressor
8212

Danfoss electrical equipment Extra connection box Fan motor Pressure switch Thermostat Black wire Blue wire Brown wire

4 3 2 1

B
1 2 N L 1 2 N L 4 1 5 2

A
M
5

Green-yellow wire
7

Main Winding Start Winding Winding Protector

C
1 2 N L 1 2 1 2 N L 3

CD.34.E1.02

September 2001

September 2001

CK.54.C1.02

33

SC15CNX LBP/MBP Condensing Unit R290 (Propane) 220-240V 50Hz


Data Sheet General
Barcode Danfoss Version Barcode Code number

Condensing unit Version N0 - for capillary tube N0 - for capillary tube Size BG3 BG4

SC15CNX Code number 114F3502 114F4502

SC15CNX
R290 Made in Ger many
Yellow background

114

F 3502

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8438-3

Application
Application Evaporating temperature range at 32C C LBP/MBP BG3: -40 to -5 BG4: -40 to 5 at 43C C BG3: -40 to -20 BG4: -40 to -10 Voltage range Maximum refrigerant charge R290 V/Hz g 198 - 254 /50 150

Flammable Refrigerant:
Unit must only be installed and serviced by authorized personnel (see instructions "Fan-cooled Condensing Units 220-240V for R290", CI.34.C).

R290

Yellow warning label

Packing data
Net weight Gross weight Package height Package width Package depth kg kg mm mm mm

114F3502
18.8 20.8 275 400 530

114F4502
20.6 22.6 320 400 590

Dimensions
Height (H) Width (W) Depth (D) Distance (a) Suction connecton Liquid connection Process connecton mm mm mm mm I.D. mm I.D. mm I.D. mm

114F3502
256 310 444 325 8.2 6.5 6.2

114F4502
296 330 451 325 8.2 6.5 6.2

325 D
drawing shows N0 version

8.5

September 2001

CD.34.F1.02

192

8 x 7
8437

228
1

34

CK.54.C1.02

September 2001

8122-3

Capacity (EN 13215/CECOMAF)


Evap. temp in C SC15CNX -BG3 SC15CNX -BG4 Evap. temp in C SC15CNX -BG3 SC15CNX -BG4 Evap. temp in C SC15CNX -BG3 SC15CNX -BG4 Evap. temp in C SC15CNX -BG3 SC15CNX -BG4 -45 -40 252 266 -40 314 337 -40 1.63 1.78 -40 244 257 -35 340 358 -35 360 381 -35 1.84 1.99 -35 329 347 -30 440 465 -30 407 425 -30 2.08 2.21 -30 426 450 -25 554 586 -25 456 471 -25 2.33 2.45 -25 535 566 -23.3 595 630 -23.3 473 487 -23.3 2.42 2.53 -23.3 575 609 -20 680 722 -20 508 519 -20 2.61 2.71 -20 657 698 -15 818 874 -15 567 572 -15 2.91 2.99 -15 790 844 -10 968 1040 -10 634 632 -10 3.24 3.29 -10 934 1004 -5 1127 1221 -5 712 701 -5 3.61 3.63 -5 1087 1177 0 1415 0 780 0 4.00 0 1363 5 1621 10

watt
15

Power consumption
-45 5 871 10

watt
15

Current consumption
-45 5 4.40 10 15

Capacity (DIN 8971)


-45 5 1559 10

watt
15

Test conditions (220V 50Hz) EN 13215/CECOMAF DIN 8971 Ambient temperature 32C 32C Suction gas temperature 32C 25C Temperature of refrigerant at condenser outlet is subcooled within the condensing limits of the unit. 1 Watt = 0.86 kcal/h, 1 Watt = 3.41 Btu/h

Spareparts
Devices Size Condenser Fancowl Fanblade Fanmotor 114F3502 BG3 118U0102 118U0403 118U0600 ( 230 mm) 118U0201 (11W) 114F4502 BG4 118U0103 118U0404 118U0601 ( 254 mm) 118U0202 (16W)

Wiring diagram
Fig. Devices A B C D E F 1 2 3 4 5 6 7 Compressor
8212

Danfoss electrical equipment Extra connection box Fan motor Pressure switch Thermostat Black wire Blue wire Brown wire

4 3 2 1

B
1 2 N L 1 2 N L 4 1 5 2

A
M
5

Green-yellow wire
7

Main Winding Start Winding Winding Protector

C
1 2 N L 1 2 1 2 N L 3

CD.34.F1.02

September 2001

September 2001

CK.54.C1.02

35

SC18CNX LBP/MBP Condensing Unit R290 (Propane) 220-240V 50Hz


Data Sheet General
Barcode Danfoss Version Barcode Code number

Condensing unit Version N0 - for capillary tube N0 - for capillary tube Size BG3 BG4

SC18CNX Code number 114F3503 114F4503

SC18CNX
R290 Made in Ger many
Yellow background

114

F 3503

Se r i a l No.
Red stripe Barcode Serial number Max. refrigerant charge Voltage and frequency 8438-4

Application
Application Evaporating temperature range at 32C C LBP/MBP BG3: -40 to -10 BG4: -40 to 0 at 43C C BG3: -40 to -25 BG4: -40 to -20 Voltage range Maximum refrigerant charge R290 V/Hz g 198 - 254 /50 150

Flammable Refrigerant:
Unit must only be installed and serviced by authorized personnel (see instructions "Fan-cooled Condensing Units 220-240V for R290", CI.34.C).

R290

Yellow warning label

Packing data
Net weight Gross weight Package height Package width Package depth kg kg mm mm mm

114F3503
18.8 20.8 275 400 530

114F4503
20.6 22.6 320 400 590

Dimensions
Height (H) Width (W) Depth (D) Distance (a) Suction connecton Liquid connection Process connecton mm mm mm mm I.D. mm I.D. mm I.D. mm

114F3503
256 310 444 325 10.2 6.5 6.2

114F4503
296 330 451 325 10.2 6.5 6.2

325 D
drawing shows N0 version

8.5

September 2001

CD.34.G1.02

192

8 x 7
8437

228
1

36

CK.54.C1.02

September 2001

8122-3

Capacity (EN 13215/CECOMAF)


Evap. temp in C SC18CNX -BG3 SC18CNX -BG4 Evap. temp in C SC18CNX -BG3 SC18CNX -BG4
Evap. temp in C SC18CNX -BG3 SC18CNX -BG4

watt
-35 374 395 -35 412 434
-35 2.35 2.50

-45

-40 271 287 -40 356 380


-40 2.12 2.27

-30 491 519 -30 471 492


-30 2.59 2.73

-25 621 658 -25 537 554


-25 2.86 2.98

-23.3 669 710 -23.3 561 576


-23.3 2.95 3.07

-20 766 814 -20 612 623


-20 3.14 3.24

-15 924 986 -15 698 701


-15 3.46 3.53

-10 1096 1173 -10 799 790


-10 3.80 3.84

-5 1376 -5 893
-5 4.19

0 1594

10

15

Power consumption
-45 0 1014 5 10

watt
15

Current consumption
-45 0 4.56 5 10 15

Capacity (DIN 8971)


Evap. temp in C SC18CNX -BG3 SC18CNX -BG4 -45 -40 262 278 -35 362 383 -30 474 502 -25 600 636 -23.3 646 685 -20 739 786 -15 891 951 -10 1055 1131 -5 1325 0 1532 5 10

watt
15

Test conditions (220V 50Hz) EN 13215/CECOMAF DIN 8971 Ambient temperature 32C 32C Suction gas temperature 32C 25C Temperature of refrigerant at condenser outlet is subcooled within the condensing limits of the unit. 1 Watt = 0.86 kcal/h, 1 Watt = 3.41 Btu/h

Spareparts
Devices Size Condenser Fancowl Fanblade Fanmotor 114F3503 BG3 118U0102 118U0403 118U0600 ( 230 mm) 118U0201 (11W) 114F4503 BG4 118U0103 118U0404 118U0601 ( 254 mm) 118U0202 (16W)

Wiring diagram
Fig. Devices A B C D E F 1 2 3 4 5 6 7 Compressor
8212

Danfoss electrical equipment Extra connection box Fan motor Pressure switch Thermostat Black wire Blue wire Brown wire

4 3 2 1

B
1 2 N L 1 2 N L 4 1 5 2

A
M
5

Green-yellow wire
7

Main Winding Start Winding Winding Protector

C
1 2 N L 1 2 1 2 N L 3

CD.34.G1.02

September 2001

September 2001

CK.54.C1.02

37

38

CK.54.C1.02

September 2001

September 2001

CK.54.C1.02

39

The Danfoss product programme for the refrigeration industry contains:

Compressors for Refrigeration and Air Conditioning A wide range of hermetic reciprocating compressors and scroll compressors as well as aircooled condensing units. The product range is applied in air conditioning units, water chillers and commercial refrigeration systems.

Compressors for Refrigerators and Freezers Hermetic compressors and fan-cooled condensing units for household refrigeration units such as refrigerators and freezers, and for commercial installations such as sales counters and bottle coolers. Compressors for heating pump systems. 12 and 24 V compressors for refrigerators and freezers in commercial vehicles, buses, and boats.

Appliance Controls For the regulation of refrigeration appliances and freezers Danfoss supply a CFC-free product range of electromechanical thermostats for refrigerators and electromechanical thermostats for refrigerators and freezers produced according to customer specification; Hermetic valves for refrigerator/freezer combinations and for energy saving applications; Service thermostats for all refrigerating and freezing appliances.

Refrigeration and Air Conditioning Controls With our full product range we cover all the requirements for mechanical and electronically controlled refrigeration systems. The functions cover: control, safety, system protection and monitoring. Our products are applied for all commercial- and industrial refrigeration applications as well as for air conditioning.

www.danfoss.com/compressors

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Compressors GmbH


Mads-Clausen-Strasse 7 Postfach 1443, D-24939 Flensburg Telefon: (0461) 4941-0 International +49 461 4941-0 Telefax: +49 461 44715 Telex: 227 43 dancom d

CK.54.C1.02

Produced by Danfoss 01.09

Das könnte Ihnen auch gefallen