Beruflich Dokumente
Kultur Dokumente
www.paclp.com
ANALYSIS RANGE
oxygenates (astm d5845) mtbe 020 vol % 020 vol % 015 vol % 015 vol % 025 vol % 025 vol % 010 vol % 05 wt % 05 vol % 025 vol % 025 vol % 86104 vol % 7796 vol % 8498 vol % 030 vol % 080 vol % 060 vol % 155265f 265375f 3070 vol % 7595 vol % 9501380 dipe ethanol t-butanol etbe tame methanol total oxygen benzene (astm d6277) toluene total xylenes octane ron mon (r+m)/2 total olefins total saturates total aromatics distillation points t50 t90 evaporation points e200 e300 driveability index
Now, one instrument produces critical results for gasoline at the touch of a button. PetroSpecs Gasoline Sensor Portable Process Analyzer (GS PPA) delivers test results in three minutes. Using mid infrared analysis, multiple chemical and physical properties are determined with far more repeatable and reproducible results than other Standard ASTM Methods. The GS PPA provides the most complete analysis of the widest gasoline blends worldwide. Each unit is factory calibrated with a diverse matrix of over 700 fuels that were developed with major, global fuel producers. No sample preparation or technical training requirements make this portable and rugged instrument ideal for lab or field use. Proven performance enables fast verification of fuel quality and specifications. Using the GS PPA allows the monitoring of product quality, optimize fuel & additive blending, ensure government compliance, verify chain of custody, and minimize transmix and contamination problems. Advanced calibration software allows for onsite fuel adaption enabling applications in or for R&D and refinery labs, at refinery process units, and catalytic pilot plants.
The GS PPAs includes calibration software that: Analyze the chemical spectrum of any calibration and apply different calibration models for added insight in seconds Gain increased accuracy with existing calibration; augment factory calibration; set training instruments to your own unique or local fuel blends Develop new refinery blending streams as well as new chemical and physical parameters Improve correlation with engine results and other test methods Benefit from various integrated features including regression analysis, a database management system and custom model definitions.
advantages
Highly accurate Mid IR spectroscopic analysis Fully automated analysis, one button operation 10mL sample size No sample preparation Low cost per test No technical training of user required ASTM methods included Field, lab or refinery use Pre-calibrated
APPLICATION RANGE
Fuel Composition Oxygenates Content Bezene Toluene Total Xylenes Octane (ROn, mon, r+m/2) Olefins Saturates Distillation Points (t50, t90) Evaporation points (e200, e300) Driveability index MMT content VOC emissions calculator - us Version only
STANDARD METHODS
In accordance with: ASTM D36 ASTM D6277
www.paclp.com
solidpartners provensolutions
U.S.A. PAC, LP | 8824 Fallbrook Drive | Houston, Texas 77064 T: +1 800.444.TEST | O: +1 281.940.1803 | F: +1 281.580.0719 sales.usa@paclp.com | service.usa@paclp.com FRANCE BP 70285 | Verson | 14653 CARPIQUET Cedex T: +33 231 264 300 | F: +33 321 266 293 sales.france@paclp.com | service.france@paclp.com GERMANY Badstrasse 3-5 | P.O.Box 1241 | D-97912 Lauda-Knigshofen, T: +49 9343 6400 | F: +49 9343 640 101 sales.germany@paclp.com| service.germany@paclp.com SINGAPORE 61 Science Park Road | #03-09/10 The Galen Singapore Science Park III | Singapore 117525 T: +65 6412 0890 | F: +65 6412 0899 sales.singapore@paclp.com | service.singapore@paclp.com NETHERLANDS P.O.Box 10.054 | 3004 AB Rotterdam Innsbruckweg 35 | 3047 AG Rotterdam T: +31 10 462 4811 | F: +31 10 462 6330 sales.netherlands@paclp.com | service.netherlands@paclp.com RUSSIA Shabolovka Street | 34, Bldg. 2 | 115419 Moscow T: +7 495 617 10 86 | F: +7 495 913 97 65 sales.russia@paclp.com | service.russia@paclp.com CHINA Room 1003, Sunjoy Mansion | No. 6 RiTan Rd. Chao Yang District | Beijing 100020 T: +86 10 650 72236 | F: +86 10 650 72454 sales.china@paclp.com | service.china@paclp.com INDIA 1508 | Dev Corpora | Pokhran Road No.1 Eastern Express Highway | Thane (W) - 400 601 T : +91-22-6700 4848 | F: +91-22-4228 4950 sales.india@paclp.com | service.india@paclp.com MIDDLE EAST A1 Quds Street, A1 Tawar road | LIU#H13 Dubai Airport Freezone Near Dubai Airport (terminal 2) | P.O.Box #54781 | Dubai, UAE T: +971 04 2947 995 | F: +971 04 2395 465 sales.middleeast@paclp.com | service.middleeast@paclp.com SOUTH KOREA #621 World Vision Building | 24-2, Youido-dong Seoul 150-010 T: +82 2785 3900 | F: +82 2785 3977 sales.southkorea@paclp.com | service.southkorea@paclp.com THAILAND 26th Floor, M. Thai Tower | All Seasons Place 87 Wireless Road | Lumpini, Phatumwan | Bangkok 10330 T: +66 2627 9410 | F: +662627 9401 sales.thailand@paclp.com | service.thailand@paclp.com PAC Authorized Representatives are also located in most countries worldwide. For more information visit www.paclp.com
SPECIFICATIONS
Ordering Information Gas Sensor Portable Process Analyzers are designed for at-line use in the refinery or for R&D laboratories. Predict Oxygenates Content (ASTM D 5845), Benzene (ASTM D 6277), Toluene, Total Xylenes, Octane (RON, MON, R+M/2), Olefins, Saturates, Distillation Points (T50, T90), Evaporation Points (E200,E300), Driveability Index, VOC Emissions Calculator, and MMT. R version user calibration software offers added method development and flexibility (see User Calibration Software). P/N BTGS-PPA US users P/N BTGS-PPA-I International users Detection Method Unique Mid-Infrared Optical Design Analysis Calibration Sample Induction Outlier Detection Highly accurate method that uses mid-infrared light to probe a fuel sample to determine its composition and predict properties. Dual beam, tuned optical, temperature controlled, filter-based instrument provides long-term accuracy and stability, resistant to vibrations and water. Each unit is factory calibrated with a diverse matrix of over 700 fuels. Pressurized delivery system purges and fills sample cell with < 10 mL of fuel for sample integrity. Unusual samples are identified based on their Mahalanobis distances from the calibration set and are indicated by an alarm message. The data from the outlier can be used to augment the factory calibration set using the provided user software. In the event that outlier fuels are detected, these outliers are easily added by the user to the calibration through user-friendly, Windows- based calibration software. This software allows the user to download the unknown spectrum to an external computer, develop new data sets including the new spectrum, produce a new regression analysis and model coefficients and substitute these new models onto the instrument. With this software the GS PPA can be run from an external computer (computer not included). Taking advantage of fully computer-controlled operation, users can easily develop new calibrations and mathematical models for existing parameters, as well as create 10 new user-defined paramenters. Calibrations easily transfer to online equipment. Temperature controlled instrument < 3 minutes 30 minutes 2 line LCD with back light Internal memory capacity stores results of up to 99 analyses, which may be viewed on the display or printed in either of two formats; infinite storage possible by remote data acquisition RS 232 serial port, exporting software; parallel printer port
Operation Temperature Control Response Time Warm-Up Time Results Display Data Management
Communication
Physical Specifications Cabinet/Chassis Fully portable, rugged aluminum with baked epoxy coating; includes a sturdy sampling fixture and carrying handle Utility Requirements 20/240 VAC 50/60 Hz or 12 VDC automobile cigarette lighter adapter for mobile use Instrument Size 25 x 25 x 30 cm; 12 kg Optional Equipment 12 VDC automobile cigarette lighter adapter for mobile use Auto surge suppressor
PETROSPEC by PAC
PetroSpec by PAC is the leading provider of dependable, portable, high-quality spectroscopic analyzers for measuring the chemical and physical properties of fuels. PetroSpec instruments are dedicated to field compliance testing for gasoline and diesel, in cooperation with the USEPA RFG program. PetroSpec produces fast and accurate analyzers for hydrocarbon fuels, bio-based fuels and petroleum products. Products include the QuickSpec Ethanol and Water Analyzer, GS PPA Gasoline Analyzer and TD PPA Diesel/Jet Fuel Analyzer and the DT100 family for determining dye concentrations in middle distillate fuels.
www.paclp.com www.paclp.com
by
USA
by
FRANCE
GERMANY
by
by
NE THERLANDS
UAE
RUSSIA
by
CHINA
by
SINGAPORE
by
SOUTH KOREA
THAILAND
INDI A