Features :
Universal AC input / Full range
N E T- 7 5
series
Protections: Short circuit / Over load / Over voltage Cooling by free air convection 100% full load burn-in test 2 years warranty
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 7) Note.4 Note.5
NET-75A CH1 5V 6A
Note.6 0.6 ~ 7A
NET-75B CH2 12V 3A CH3 -5V 0.5A CH1 5V 5A 64.6W CH1: 4.75 ~ 5.5V 2.0% 6.0% 0.5% 1.5% 1.0% 3.0% CH2 12V 2.8A CH3 -12V 0.5A
NET-75C CH1 5V 6A 72W CH1: 4.75 ~ 5.5V 2.0% 8.0% 0.5% 1.5% 1.0% 3.0% CH2 15V 2.3A CH3 -15V 0.5A
NET-75D CH1 5V 5A 73W CH1: 4.75 ~ 5.5V 2.0% 8.0% 0.5% 1.5% 1.0% 3.0% CH2 24V 1.5A 0.1 ~ 2A CH3 12V 1A 0.1 ~ 1.5A
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 150mVp-p 80mVp-p 200mVp-p 120mVp-p 5.0% 1.0% 1.0% 5.0% 1.0% 1.0% 5.0% 1.0% 1.0% 6.0% 1.0% 3.0%
1.5A/115VAC 0.9A/230VAC COLD START 45A <2mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CB(IEC60950-1) approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY MTBF 361.6K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.52Kg; 30pcs/16.6Kg/0.97CUFT )
ISOLATION RESISTANCE
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
OTHERS
DIMENSION PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
File Name:NET-75-SPEC 2010-10-18
N E T- 7 5
Case No. 901
series
Unit:mm
9.5
2 3 4
65
3.5 84.5
7
8.2
5 6 7 +V ADJ.
2 -M
3.5
4.5 24 78 159 6.5 150
18.5
22
117
Block Diagram
RECTIFIERS & FILTER RECTIFIERS & FILTER I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. V3
fosc : 60KHz
FG O.L.P. CONTROL
Derating Curve
100
100 90
80
80
60
70
LOAD (%)
LOAD (%)
40
60 50 40
20
-20
10
20
30
40
50
60
70
(HORIZONTAL)
85
95
100
115
120
140
160
180
200
220
240
AMBIENT TEMPERATURE ( )
28.5
264
M3
18
3-
3.5
38
97
3.5