Sie sind auf Seite 1von 52

FOUR SPAN

10010

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F100-Four Spans for Z/C100 Sections - Limit state capacity (kN/m)
SECTION

10010

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900
4200
4500
4800
5100
5400
5700

3.64
2.79
2.20
1.78
1.48
1.24
1.06
0.91
0.79
0.70
0.62
0.55
0.49

3.64
2.79
2.20
1.78
1.48
1.24
1.06
0.91
0.79
0.70
0.62
0.55
0.49

3.64
2.79
2.20
1.78
1.48
1.24
1.06
0.91
0.79
0.70
0.62
0.55
0.49

3.64
2.79
2.20
1.78
1.48
1.24
1.06
0.91
0.79
0.70
0.62
0.55
0.49

3.64
2.79
2.20
1.78
1.48
1.24
1.06
0.91
0.79
0.70
0.62
0.55
0.49

7.05
4.72
3.32
2.42
1.82
1.40
1.10
0.88
0.72
0.59
0.49
0.41
0.35

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150

10012

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F100-Four Spans for Z/C100 Sections - Limit state capacity (kN/m)
SECTION

10012

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300
6600

4.84
3.71
2.93
2.37
1.96
1.65
1.40
1.21
1.05
0.93
0.82
0.73
0.66
0.59
0.54
0.49

4.84
3.71
2.93
2.37
1.96
1.65
1.40
1.21
1.05
0.93
0.82
0.73
0.66
0.59
0.54

4.84
3.71
2.93
2.37
1.96
1.65
1.40
1.21
1.05
0.93
0.82
0.73
0.66
0.59
0.54
0.49

4.84
3.71
2.93
2.37
1.96
1.65
1.40
1.21
1.05
0.93
0.82
0.73
0.66
0.59
0.54
0.49

4.84
3.71
2.93
2.37
1.96
1.65
1.40
1.21
1.05
0.93
0.82
0.73
0.66
0.59
0.54
0.49

8.73
5.85
4.11
2.99
2.25
1.73
1.36
1.09
0.89
0.73
0.61
0.51
0.44
0.37
0.32
0.28

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150

10015

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F100-Four Spans for Z/C100 Sections - Limit state capacity (kN/m)
SECTION

10015

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000

6.38
4.88
3.86
3.12
2.58
2.17
1.85
1.59
1.39
1.22
1.08
0.96
0.87
0.78

6.21
4.76
3.76
3.04
2.52
2.11
1.80
1.55
1.35
1.19
1.05
0.94
0.84
0.76

6.38
4.88
3.86
3.12
2.58
2.17
1.85
1.59
1.39
1.22
1.08
0.96
0.87
0.78

6.38
4.88
3.86
3.12
2.58
2.17
1.85
1.59
1.39
1.22
1.08
0.96
0.87
0.78

6.38
4.88
3.86
3.12
2.58
2.17
1.85
1.59
1.39
1.22
1.08
0.96
0.87
0.78

11.13
7.46
5.24
3.82
2.87
2.21
1.74
1.39
1.13
0.93
0.78
0.65
0.56
0.48

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
10019

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F100-Four Spans for Z/C100 Sections - Limit state capacity (kN/m)
SECTION

10019

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500

8.63
6.61
5.22
4.23
3.49
2.94
2.50
2.16
1.88
1.65
1.46
1.31
1.17
1.06
0.96
0.87
0.80
0.73
0.68

7.78
5.96
4.71
3.81
3.15
2.65
2.26
1.95
1.69
1.49
1.32
1.18
1.06
0.95
0.86
0.79
0.72
0.66
0.61

8.63
6.61
5.22
4.23
3.49
2.94
2.50
2.16
1.88
1.65
1.46
1.31
1.17
1.06
0.96
0.87
0.80
0.73
0.68

8.63
6.61
5.22
4.23
3.49
2.94
2.50
2.16
1.88
1.65
1.46
1.31
1.17
1.06
0.96
0.87
0.80
0.73
0.68

8.63
6.61
5.22
4.23
3.49
2.94
2.50
2.16
1.88
1.65
1.46
1.31
1.17
1.06
0.96
0.87
0.80
0.73
0.68

13.95
9.34
6.56
4.78
3.59
2.77
2.18
1.74
1.42
1.17
0.97
0.82
0.70
0.60
0.52
0.45
0.39
0.35
0.31

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.

OUT = outward load capacity.


DEF. = Load required to give a deflection of SPAN/150
15012

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F150-Four Spans for Z/C150 Sections - Limit state capacity (kN/m)
SECTION

15012

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500

6.82
5.73
4.53
3.67
3.03
2.55
2.17
1.87
1.63
1.43
1.27
1.13
1.02
0.92
0.83
0.76
0.69
0.64
0.59

6.82
5.73
4.53
3.67
3.03
2.55
2.17
1.87
1.63
1.43
1.27
1.13
1.02
0.92
0.83
0.76
0.69
0.64
0.59

6.82
5.73
4.53
3.67
3.03
2.55
2.17
1.87
1.63
1.43
1.27
1.13
1.02
0.92
0.83
0.76
0.69
0.64
0.59

6.82
5.73
4.53
3.67
3.03
2.55
2.17
1.87
1.63
1.43
1.27
1.13
1.02
0.92
0.83
0.76
0.69
0.64
0.59

6.82
5.73
4.53
3.67
3.03
2.55
2.17
1.87
1.63
1.43
1.27
1.13
1.02
0.92
0.83
0.76
0.69
0.64
0.59

24.97
16.73
11.75
8.57
6.44
4.96
3.90
3.12
2.54
2.09
1.74
1.47
1.25
1.07
0.92
0.80
0.70
0.62
0.55

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging

systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
15015

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F150-Four Spans for Z/C150 Sections - Limit state capacity (kN/m)
SECTION

15015

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000

11.18
8.56
6.76
5.48
4.53
3.80
3.24
2.80
2.44
2.14
1.90
1.69
1.52
1.37
1.24
1.13
1.04
0.95
0.88
0.81
0.75
0.70
0.65
0.61

11.18
8.56
6.76
5.48
4.53
3.80
3.24
2.80
2.44
2.14
1.90
1.69
1.52
1.37
1.24
1.13
1.04
0.95
0.88
0.81
0.75
0.70
0.65
0.61

11.18
8.56
6.76
5.48
4.53
3.80
3.24
2.80
2.44
2.14
1.90
1.69
1.52
1.37
1.24
1.13
1.04
0.95
0.88
0.81
0.75
0.70
0.65
0.61

11.18
8.56
6.76
5.48
4.53
3.80
3.24
2.80
2.44
2.14
1.90
1.69
1.52
1.37
1.24
1.13
1.04
0.95
0.88
0.81
0.75
0.70
0.65
0.61

11.18
8.56
6.76
5.48
4.53
3.80
3.24
2.80
2.44
2.14
1.90
1.69
1.52
1.37
1.24
1.13
1.04
0.95
0.88
0.81
0.75
0.70
0.65
0.61

32.36
21.68
15.22
11.10
8.34
6.42
5.05
4.04
3.29
2.71
2.26
1.90
1.62
1.39
1.20
1.04
0.91
0.80
0.71
0.63
0.56
0.51
0.46
0.41

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
15019

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F150-Four Spans for Z/C150 Sections - Limit state capacity (kN/m)
SECTION

15019

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300

15.87
12.15
9.60
7.78
6.43
5.40
4.60
3.97
3.46
3.04
2.69
2.40
2.15
1.94
1.76

15.70
12.02
9.50
7.69
6.36
5.34
4.55
3.93
3.42
3.01
2.66
2.37
2.13
1.92
1.74

15.87
12.15
9.60
7.78
6.43
5.40
4.60
3.97
3.46
3.04
2.69
2.40
2.15
1.94
1.76

15.87
12.15
9.60
7.78
6.43
5.40
4.60
3.97
3.46
3.04
2.69
2.40
2.15
1.94
1.76

15.87
12.15
9.60
7.78
6.43
5.40
4.60
3.97
3.46
3.04
2.69
2.40
2.15
1.94
1.76

41.73
27.95
19.63
14.31
10.75
8.28
6.51
5.22
4.24
3.49
2.91
2.45
2.09
1.79
1.55

6600
6900
7200
7500
7800
8100
8400
8700
9000

1.61
1.47
1.35
1.24
1.15
1.07
0.99
0.92
0.86

1.59
1.45
1.34
1.23
1.14
1.06
0.98
0.91
0.85

1.61
1.47
1.35
1.24
1.15
1.07
0.99
0.92
0.86

1.61
1.47
1.35
1.24
1.15
1.07
0.99
0.92
0.86

1.61
1.47
1.35
1.24
1.15
1.07
0.99
0.92
0.86

1.34
1.18
1.04
0.92
0.81
0.73
0.65
0.59
0.53

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
15024

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F150-Four Spans for Z/C150 Sections - Limit state capacity (kN/m)
SECTION

15024

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

2100
2400
2700
3000
3300
3600
3900

21.60
16.53
13.06
10.58
8.75
7.35
6.26

19.61
15.02
11.87
9.61
7.94
6.67
5.69

21.60
16.53
13.06
10.58
8.75
7.35
6.26

21.60
16.53
13.06
10.58
8.75
7.35
6.26

21.60
16.53
13.06
10.58
8.75
7.35
6.26

52.46
35.14
24.68
17.99
13.52
10.41
8.19

4200
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000

5.40
4.70
4.13
3.66
3.27
2.93
2.65
2.40
2.19
2.00
1.84
1.69
1.57
1.45
1.35
1.26
1.18
1.10
1.03
0.97
0.92
0.86
0.82
0.77
0.73
0.70
0.66

4.90
4.27
3.75
3.33
2.97
2.66
2.40
2.18
1.99
1.82
1.67
1.54
1.42
1.32
1.23
1.14
1.07
1.00
0.94
0.88
0.83
0.78
0.74
0.70
0.67
0.63
0.60

5.40
4.70
4.13
3.66
3.27
2.93
2.65
2.40
2.19
2.00
1.84
1.69
1.57
1.45
1.35
1.26
1.18
1.10
1.03
0.97
0.92
0.86
0.82
0.77
0.73
0.70
0.66

5.40
4.70
4.13
3.66
3.27
2.93
2.65
2.40
2.19
2.00
1.84
1.69
1.57
1.45
1.35
1.26
1.18
1.10
1.03
0.97
0.92
0.86
0.82
0.77
0.73
0.70
0.66

5.40
4.70
4.13
3.66
3.27
2.93
2.65
2.40
2.19
2.00
1.84
1.69
1.57
1.45
1.35
1.26
1.18
1.10
1.03
0.97
0.92
0.86
0.82
0.77
0.73
0.70
0.66

6.56
5.33
4.39
3.66
3.09
2.62
2.25
1.94
1.69
1.48
1.30
1.15
1.02
0.91
0.82
0.74
0.67
0.60
0.55
0.50
0.46
0.42
0.39
0.36
0.33
0.30
0.28

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
20015

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F200-Four Spans for Z/C200 Sections - Limit state capacity (kN/m)
SECTION

20015

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000

6.57
5.43
4.56
3.89
3.35
2.92
2.57
2.27
2.03
1.82
1.64
1.49
1.36
1.24
1.14
1.05
0.97
0.90
0.84
0.78
0.73

6.57
5.43
4.56
3.89
3.35
2.92
2.57
2.27
2.03
1.82
1.64
1.49
1.36
1.24
1.14
1.05
0.97
0.90
0.84
0.78
0.73

6.57
5.43
4.56
3.89
3.35
2.92
2.57
2.27
2.03
1.82
1.64
1.49
1.36
1.24
1.14
1.05
0.97
0.90
0.84
0.78
0.73

6.57
5.43
4.56
3.89
3.35
2.92
2.57
2.27
2.03
1.82
1.64
1.49
1.36
1.24
1.14
1.05
0.97
0.90
0.84
0.78
0.73

6.57
5.43
4.56
3.89
3.35
2.92
2.57
2.27
2.03
1.82
1.64
1.49
1.36
1.24
1.14
1.05
0.97
0.90
0.84
0.78
0.73

23.48
17.64
13.59
10.69
8.56
6.96
5.73
4.78
4.03
3.42
2.94
2.54
2.21
1.93
1.70
1.50
1.34
1.19
1.07
0.96
0.87

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.

OUT = outward load capacity.


DEF. = Load required to give a deflection of SPAN/150
20019

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F200-Four Spans for Z/C200 Sections - Limit state capacity (kN/m)
SECTION

20019

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100

11.45
9.46
7.95
6.78
5.84
5.09
4.47
3.96
3.53
3.17
2.86
2.60
2.37
2.16
1.99
1.83
1.69
1.57
1.46
1.36
1.27
1.19
1.12
1.05
0.99
0.93
0.88
0.84

11.45
9.46
7.95
6.78
5.84
5.09
4.47
3.96
3.53
3.17
2.86
2.60
2.37
2.16
1.99
1.83
1.69
1.57
1.46
1.36
1.27
1.19
1.12
1.05
0.99
0.93
0.88
0.84

11.45
9.46
7.95
6.78
5.84
5.09
4.47
3.96
3.53
3.17
2.86
2.60
2.37
2.16
1.99
1.83
1.69
1.57
1.46
1.36
1.27
1.19
1.12
1.05
0.99
0.93
0.88
0.84

11.45
9.46
7.95
6.78
5.84
5.09
4.47
3.96
3.53
3.17
2.86
2.60
2.37
2.16
1.99
1.83
1.69
1.57
1.46
1.36
1.27
1.19
1.12
1.05
0.99
0.93
0.88
0.84

11.45
9.46
7.95
6.78
5.84
5.09
4.47
3.96
3.53
3.17
2.86
2.60
2.37
2.16
1.99
1.83
1.69
1.57
1.46
1.36
1.27
1.19
1.12
1.05
0.99
0.93
0.88
0.84

31.37
23.57
18.15
14.28
11.43
9.30
7.66
6.39
5.38
4.57
3.92
3.39
2.95
2.58
2.27
2.01
1.78
1.59
1.43
1.29
1.16
1.05
0.96
0.87
0.80
0.73
0.67
0.62

11400
11700
12000

0.79
0.75
0.72

0.79
0.75
0.72

0.79
0.75
0.72

0.79
0.75
0.72

0.79
0.75
0.72

0.57
0.53
0.49

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
20024

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F200-Four Spans for Z/C200 Sections - Limit state capacity (kN/m)
SECTION

20024

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300

15.10
13.74
11.55
9.84
8.48
7.39
6.50
5.75
5.13
4.61
4.16
3.77

15.10
13.45
11.31
9.63
8.31
7.24
6.36
5.63
5.02
4.51
4.07
3.69

15.10
13.74
11.55
9.84
8.48
7.39
6.50
5.75
5.13
4.61
4.16
3.77

15.10
13.74
11.55
9.84
8.48
7.39
6.50
5.75
5.13
4.61
4.16
3.77

15.10
13.74
11.55
9.84
8.48
7.39
6.50
5.75
5.13
4.61
4.16
3.77

40.54
30.45
23.46
18.45
14.77
12.01
9.90
8.25
6.95
5.91
5.07
4.38

6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000

3.44
3.14
2.89
2.66
2.46
2.28
2.12
1.98
1.85
1.73
1.62
1.53
1.44
1.36
1.28
1.21
1.15
1.09
1.04

3.36
3.08
2.83
2.60
2.41
2.23
2.08
1.94
1.81
1.69
1.59
1.49
1.41
1.33
1.26
1.19
1.13
1.07
1.02

3.44
3.14
2.89
2.66
2.46
2.28
2.12
1.98
1.85
1.73
1.62
1.53
1.44
1.36
1.28
1.21
1.15
1.09
1.04

3.44
3.14
2.89
2.66
2.46
2.28
2.12
1.98
1.85
1.73
1.62
1.53
1.44
1.36
1.28
1.21
1.15
1.09
1.04

3.44
3.14
2.89
2.66
2.46
2.28
2.12
1.98
1.85
1.73
1.62
1.53
1.44
1.36
1.28
1.21
1.15
1.09
1.04

3.81
3.33
2.93
2.59
2.31
2.06
1.85
1.66
1.50
1.36
1.24
1.13
1.03
0.95
0.87
0.80
0.74
0.68
0.63

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
25019

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F250-Four Spans for Z/C250 Sections - Limit state capacity (kN/m)

SECTION

25019

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

3000
3300
3600
3900
4200
4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000

14.22
11.75
9.87
8.41
7.26
6.32
5.55
4.92
4.39
3.94
3.55
3.22
2.94
2.69
2.47
2.28
2.10
1.95
1.81
1.69
1.58
1.48
1.39
1.31
1.23
1.16
1.10
1.04
0.98
0.93
0.89

14.22
11.75
9.87
8.41
7.26
6.32
5.55
4.92
4.39
3.94
3.55
3.22
2.94
2.69
2.47
2.28
2.10
1.95
1.81
1.69
1.58
1.48
1.39
1.31
1.23
1.16
1.10
1.04
0.98
0.93
0.89

14.22
11.75
9.87
8.41
7.26
6.32
5.55
4.92
4.39
3.94
3.55
3.22
2.94
2.69
2.47
2.28
2.10
1.95
1.81
1.69
1.58
1.48
1.39
1.31
1.23
1.16
1.10
1.04
0.98
0.93
0.89

14.22
11.75
9.87
8.41
7.26
6.32
5.55
4.92
4.39
3.94
3.55
3.22
2.94
2.69
2.47
2.28
2.10
1.95
1.81
1.69
1.58
1.48
1.39
1.31
1.23
1.16
1.10
1.04
0.98
0.93
0.89

14.22
11.75
9.87
8.41
7.26
6.32
5.55
4.92
4.39
3.94
3.55
3.22
2.94
2.69
2.47
2.28
2.10
1.95
1.81
1.69
1.58
1.48
1.39
1.31
1.23
1.16
1.10
1.04
0.98
0.93
0.89

53.04
39.85
30.70
24.14
19.33
15.72
12.95
10.80
9.10
7.73
6.63
5.73
4.98
4.36
3.84
3.39
3.02
2.69
2.42
2.17
1.96
1.78
1.62
1.48
1.35
1.24
1.14
1.05
0.97
0.89
0.83

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds

the normal delivery length (12000 mm nominal).


5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
25024

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F250-Four Spans for Z/C250 Sections - Limit state capacity (kN/m)
SECTION

25024

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000

9.55
8.40
7.44
6.63
5.95
5.37
4.87
4.44
4.06
3.73
3.44
3.18
2.95
2.74
2.56
2.39
2.24
2.10
1.97
1.86
1.75
1.66
1.57
1.49
1.41
1.34

9.55
8.40
7.44
6.63
5.95
5.37
4.87
4.44
4.06
3.73
3.44
3.18
2.95
2.74
2.56
2.39
2.24
2.10
1.97
1.86
1.75
1.66
1.57
1.49
1.41
1.34

9.55
8.40
7.44
6.63
5.95
5.37
4.87
4.44
4.06
3.73
3.44
3.18
2.95
2.74
2.56
2.39
2.24
2.10
1.97
1.86
1.75
1.66
1.57
1.49
1.41
1.34

9.55
8.40
7.44
6.63
5.95
5.37
4.87
4.44
4.06
3.73
3.44
3.18
2.95
2.74
2.56
2.39
2.24
2.10
1.97
1.86
1.75
1.66
1.57
1.49
1.41
1.34

9.55
8.40
7.44
6.63
5.95
5.37
4.87
4.44
4.06
3.73
3.44
3.18
2.95
2.74
2.56
2.39
2.24
2.10
1.97
1.86
1.75
1.66
1.57
1.49
1.41
1.34

20.32
16.74
13.96
11.76
10.00
8.57
7.40
6.44
5.64
4.96
4.39
3.90
3.48
3.12
2.81
2.54
2.30
2.09
1.91
1.74
1.60
1.47
1.35
1.25
1.16
1.07

12300
12600
12900
13200
13500
13800
14100
14400
14700
15000
15300
15600
15900
16200
16500
16800
17100
17400
17700
18000

1.28
1.22
1.16
1.11
1.06
1.02
0.97
0.93
0.90
0.86
0.83
0.79
0.77
0.74
0.71
0.69
0.66
0.64
0.62
0.60

1.28
1.22
1.16
1.11
1.06
1.02
0.97
0.93
0.90
0.86
0.83
0.79
0.77
0.74
0.71
0.69
0.66
0.64
0.62
0.60

1.28
1.22
1.16
1.11
1.06
1.02
0.97
0.93
0.90
0.86
0.83
0.79
0.77
0.74
0.71
0.69
0.66
0.64
0.62
0.60

1.28
1.22
1.16
1.11
1.06
1.02
0.97
0.93
0.90
0.86
0.83
0.79
0.77
0.74
0.71
0.69
0.66
0.64
0.62
0.60

1.28
1.22
1.16
1.11
1.06
1.02
0.97
0.93
0.90
0.86
0.83
0.79
0.77
0.74
0.71
0.69
0.66
0.64
0.62
0.60

0.99
0.93
0.86
0.81
0.75
0.70
0.66
0.62
0.58
0.55
0.52
0.49
0.46
0.44
0.41
0.39
0.37
0.35
0.33
0.32

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
30024

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

span (mm)

Table F300-Four Spans for Z/C300 Sections - Limit state capacity (kN/m)
SECTION

30024

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

4500
4800
5100
5400
5700
6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000
12300
12600
12900
13200
13500
13800
14100
14400
14700
15000
15300
15600
15900
16200
16500

12.99
11.42
10.12
9.02
8.10
7.31
6.63
6.04
5.53
5.08
4.68
4.32
4.01
3.73
3.48
3.25
3.04
2.85
2.68
2.53
2.39
2.26
2.14
2.02
1.92
1.83
1.74
1.66
1.58
1.51
1.44
1.38
1.32
1.27
1.22
1.17
1.12
1.08
1.04
1.00
0.97

12.99
11.42
10.12
9.02
8.10
7.31
6.63
6.04
5.53
5.08
4.68
4.32
4.01
3.73
3.48
3.25
3.04
2.85
2.68
2.53
2.39
2.26
2.14
2.02
1.92
1.83
1.74
1.66
1.58
1.51
1.44
1.38
1.32
1.27
1.22
1.17
1.12
1.08
1.04
1.00
0.97

12.99
11.42
10.12
9.02
8.10
7.31
6.63
6.04
5.53
5.08
4.68
4.32
4.01
3.73
3.48
3.25
3.04
2.85
2.68
2.53
2.39
2.26
2.14
2.02
1.92
1.83
1.74
1.66
1.58
1.51
1.44
1.38
1.32
1.27
1.22
1.17
1.12
1.08
1.04
1.00
0.97

12.99
11.42
10.12
9.02
8.10
7.31
6.63
6.04
5.53
5.08
4.68
4.32
4.01
3.73
3.48
3.25
3.04
2.85
2.68
2.53
2.39
2.26
2.14
2.02
1.92
1.83
1.74
1.66
1.58
1.51
1.44
1.38
1.32
1.27
1.22
1.17
1.12
1.08
1.04
1.00
0.97

12.99
11.42
10.12
9.02
8.10
7.31
6.63
6.04
5.53
5.08
4.68
4.32
4.01
3.73
3.48
3.25
3.04
2.85
2.68
2.53
2.39
2.26
2.14
2.02
1.92
1.83
1.74
1.66
1.58
1.51
1.44
1.38
1.32
1.27
1.22
1.17
1.12
1.08
1.04
1.00
0.97

34.86
28.72
23.95
20.17
17.15
14.71
12.70
11.05
9.67
8.51
7.53
6.69
5.98
5.36
4.82
4.36
3.95
3.59
3.27
2.99
2.74
2.52
2.32
2.14
1.98
1.84
1.71
1.59
1.48
1.38
1.29
1.21
1.13
1.06
1.00
0.94
0.89
0.84
0.79
0.75
0.71

16800
17100
17400
17700
18000

0.93
0.90
0.87
0.84
0.81

0.93
0.90
0.87
0.84
0.81

0.93
0.90
0.87
0.84
0.81

0.93
0.90
0.87
0.84
0.81

0.93
0.90
0.87
0.84
0.81

0.67
0.64
0.60
0.57
0.54

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
30030

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F300-Four Spans for Z/C300 Sections - Limit state capacity (kN/m)
SECTION

30030

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

6000
6300
6600
6900
7200
7500
7800
8100
8400
8700

10.48
9.50
8.66
7.92
7.28
6.70
6.20
5.75
5.34
4.98

10.34
9.38
8.55
7.82
7.18
6.62
6.12
5.67
5.28
4.92

10.48
9.50
8.66
7.92
7.28
6.70
6.20
5.75
5.34
4.98

10.48
9.50
8.66
7.92
7.28
6.70
6.20
5.75
5.34
4.98

10.48
9.50
8.66
7.92
7.28
6.70
6.20
5.75
5.34
4.98

18.98
16.39
14.26
12.48
10.98
9.72
8.64
7.71
6.92
6.22

9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000
12300
12600
12900
13200
13500
13800
14100
14400
14700
15000
15300
15600
15900
16200
16500
16800
17100
17400
17700
18000

4.66
4.36
4.09
3.85
3.62
3.42
3.23
3.06
2.90
2.76
2.62
2.49
2.38
2.27
2.16
2.07
1.98
1.90
1.82
1.75
1.68
1.61
1.55
1.49
1.44
1.39
1.34
1.29
1.25
1.20
1.16

4.60
4.30
4.04
3.80
3.58
3.38
3.19
3.02
2.86
2.72
2.59
2.46
2.34
2.24
2.14
2.04
1.95
1.87
1.80
1.72
1.65
1.59
1.53
1.47
1.42
1.37
1.32
1.27
1.23
1.19
1.15

4.66
4.36
4.09
3.85
3.62
3.42
3.23
3.06
2.90
2.76
2.62
2.49
2.38
2.27
2.16
2.07
1.98
1.90
1.82
1.75
1.68
1.61
1.55
1.49
1.44
1.39
1.34
1.29
1.25
1.20
1.16

4.66
4.36
4.09
3.85
3.62
3.42
3.23
3.06
2.90
2.76
2.62
2.49
2.38
2.27
2.16
2.07
1.98
1.90
1.82
1.75
1.68
1.61
1.55
1.49
1.44
1.39
1.34
1.29
1.25
1.20
1.16

4.66
4.36
4.09
3.85
3.62
3.42
3.23
3.06
2.90
2.76
2.62
2.49
2.38
2.27
2.16
2.07
1.98
1.90
1.82
1.75
1.68
1.61
1.55
1.49
1.44
1.39
1.34
1.29
1.25
1.20
1.16

5.62
5.10
4.63
4.22
3.86
3.54
3.25
3.00
2.77
2.56
2.37
2.20
2.05
1.91
1.78
1.67
1.56
1.46
1.37
1.29
1.21
1.14
1.08
1.02
0.96
0.91
0.86
0.82
0.78
0.74
0.70

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150

35030

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F350-Four Spans for Z/C350 Sections - Limit state capacity (kN/m)
SECTION

35030

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000
12300
12600
12900
13200
13500
13800
14100
14400
14700

12.61
11.44
10.42
9.53
8.76
8.07
7.46
6.92
6.43
6.00
5.60
5.25
4.93
4.63
4.36
4.12
3.89
3.68
3.49
3.32
3.15
3.00
2.86
2.73
2.61
2.49
2.38
2.28
2.19
2.10

12.61
11.44
10.42
9.53
8.76
8.07
7.46
6.92
6.43
6.00
5.60
5.25
4.93
4.63
4.36
4.12
3.89
3.68
3.49
3.32
3.15
3.00
2.86
2.73
2.61
2.49
2.38
2.28
2.19
2.10

12.61
11.44
10.42
9.53
8.76
8.07
7.46
6.92
6.43
6.00
5.60
5.25
4.93
4.63
4.36
4.12
3.89
3.68
3.49
3.32
3.15
3.00
2.86
2.73
2.61
2.49
2.38
2.28
2.19
2.10

12.61
11.44
10.42
9.53
8.76
8.07
7.46
6.92
6.43
6.00
5.60
5.25
4.93
4.63
4.36
4.12
3.89
3.68
3.49
3.32
3.15
3.00
2.86
2.73
2.61
2.49
2.38
2.28
2.19
2.10

12.61
11.44
10.42
9.53
8.76
8.07
7.46
6.92
6.43
6.00
5.60
5.25
4.93
4.63
4.36
4.12
3.89
3.68
3.49
3.32
3.15
3.00
2.86
2.73
2.61
2.49
2.38
2.28
2.19
2.10

30.56
26.40
22.96
20.09
17.68
15.65
13.91
12.42
11.14
10.02
9.05
8.21
7.46
6.80
6.22
5.70
5.24
4.83
4.45
4.12
3.82
3.55
3.30
3.07
2.87
2.68
2.51
2.35
2.21
2.08

15000
15300
15600
15900
16200
16500
16800
17100
17400
17700
18000

2.02
1.94
1.87
1.80
1.73
1.67
1.61
1.55
1.50
1.45
1.40

2.02
1.94
1.87
1.80
1.73
1.67
1.61
1.55
1.50
1.45
1.40

2.02
1.94
1.87
1.80
1.73
1.67
1.61
1.55
1.50
1.45
1.40

2.02
1.94
1.87
1.80
1.73
1.67
1.61
1.55
1.50
1.45
1.40

2.02
1.94
1.87
1.80
1.73
1.67
1.61
1.55
1.50
1.45
1.40

1.96
1.84
1.74
1.64
1.55
1.47
1.39
1.32
1.25
1.19
1.13

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
35024

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F350-Four Spans for Z/C350 Sections - Limit state capacity (kN/m)
SECTION

35024

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

6000
6300
6600
6900

8.89
8.06
7.35
6.72

8.89
8.06
7.35
6.72

8.89
8.06
7.35
6.72

8.89
8.06
7.35
6.72

8.89
8.06
7.35
6.72

23.86
20.61
17.92
15.69

7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000
12300
12600
12900
13200
13500
13800
14100
14400
14700
15000
15300
15600
15900
16200
16500
16800
17100
17400
17700
18000

6.17
5.69
5.26
4.88
4.53
4.23
3.95
3.70
3.47
3.26
3.08
2.90
2.74
2.60
2.46
2.34
2.22
2.12
2.02
1.92
1.84
1.76
1.68
1.61
1.54
1.48
1.42
1.37
1.31
1.27
1.22
1.18
1.13
1.09
1.06
1.02
0.99

6.17
5.69
5.26
4.88
4.53
4.23
3.95
3.70
3.47
3.26
3.08
2.90
2.74
2.60
2.46
2.34
2.22
2.12
2.02
1.92
1.84
1.76
1.68
1.61
1.54
1.48
1.42
1.37
1.31
1.27
1.22
1.18
1.13
1.09
1.06
1.02
0.99

6.17
5.69
5.26
4.88
4.53
4.23
3.95
3.70
3.47
3.26
3.08
2.90
2.74
2.60
2.46
2.34
2.22
2.12
2.02
1.92
1.84
1.76
1.68
1.61
1.54
1.48
1.42
1.37
1.31
1.27
1.22
1.18
1.13
1.09
1.06
1.02
0.99

6.17
5.69
5.26
4.88
4.53
4.23
3.95
3.70
3.47
3.26
3.08
2.90
2.74
2.60
2.46
2.34
2.22
2.12
2.02
1.92
1.84
1.76
1.68
1.61
1.54
1.48
1.42
1.37
1.31
1.27
1.22
1.18
1.13
1.09
1.06
1.02
0.99

6.17
5.69
5.26
4.88
4.53
4.23
3.95
3.70
3.47
3.26
3.08
2.90
2.74
2.60
2.46
2.34
2.22
2.12
2.02
1.92
1.84
1.76
1.68
1.61
1.54
1.48
1.42
1.37
1.31
1.27
1.22
1.18
1.13
1.09
1.06
1.02
0.99

13.81
12.22
10.86
9.70
8.69
7.83
7.07
6.41
5.82
5.31
4.86
4.45
4.09
3.77
3.48
3.22
2.98
2.77
2.58
2.40
2.24
2.09
1.96
1.84
1.73
1.62
1.53
1.44
1.36
1.28
1.21
1.15
1.09
1.03
0.98
0.93
0.88

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging

systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
40024

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F400-Four Spans for Z/C400 Sections - Limit state capacity (kN/m)
SECTION

40024

LOADING Inward

Outward

DEF

BRIDGING

0,1,2,3

6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000
12300
12600
12900

9.95
9.02
8.22
7.52
6.91
6.37
5.89
5.46
5.07
4.73
4.42
4.14
3.89
3.65
3.44
3.25
3.07
2.91
2.76
2.62
2.49
2.37
2.26
2.15

9.95
9.02
8.22
7.52
6.91
6.37
5.89
5.46
5.07
4.73
4.42
4.14
3.89
3.65
3.44
3.25
3.07
2.91
2.76
2.62
2.49
2.37
2.26
2.15

9.95
9.02
8.22
7.52
6.91
6.37
5.89
5.46
5.07
4.73
4.42
4.14
3.89
3.65
3.44
3.25
3.07
2.91
2.76
2.62
2.49
2.37
2.26
2.15

9.95
9.02
8.22
7.52
6.91
6.37
5.89
5.46
5.07
4.73
4.42
4.14
3.89
3.65
3.44
3.25
3.07
2.91
2.76
2.62
2.49
2.37
2.26
2.15

9.95
9.02
8.22
7.52
6.91
6.37
5.89
5.46
5.07
4.73
4.42
4.14
3.89
3.65
3.44
3.25
3.07
2.91
2.76
2.62
2.49
2.37
2.26
2.15

32.74
28.28
24.60
21.53
18.95
16.76
14.90
13.31
11.93
10.74
9.70
8.79
7.99
7.29
6.66
6.11
5.61
5.17
4.77
4.42
4.09
3.80
3.54
3.29

13200
13500
13800
14100
14400
14700
15000
15300
15600
15900
16200
16500
16800
17100
17400
17700
18000

2.06
1.96
1.88
1.80
1.73
1.66
1.59
1.53
1.47
1.42
1.36
1.32
1.27
1.22
1.18
1.14
1.11

2.06
1.96
1.88
1.80
1.73
1.66
1.59
1.53
1.47
1.42
1.36
1.32
1.27
1.22
1.18
1.14
1.11

2.06
1.96
1.88
1.80
1.73
1.66
1.59
1.53
1.47
1.42
1.36
1.32
1.27
1.22
1.18
1.14
1.11

2.06
1.96
1.88
1.80
1.73
1.66
1.59
1.53
1.47
1.42
1.36
1.32
1.27
1.22
1.18
1.14
1.11

2.06
1.96
1.88
1.80
1.73
1.66
1.59
1.53
1.47
1.42
1.36
1.32
1.27
1.22
1.18
1.14
1.11

3.07
2.87
2.69
2.52
2.37
2.23
2.10
1.97
1.86
1.76
1.66
1.57
1.49
1.41
1.34
1.28
1.21

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads
1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa
1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150
40030

span (mm)

span (mm)

span (mm)

span (mm)

over all purlin length = 4 x span + 70 mm

Four span

Table F400-Four Spans for Z/C400 Sections - Limit state capacity (kN/m)
SECTION
LOADING Inward

40030
Outward

DEF

BRIDGING

0,1,2,3

6000
6300
6600
6900
7200
7500
7800
8100
8400
8700
9000
9300
9600
9900
10200
10500
10800
11100
11400
11700
12000
12300
12600
12900
13200
13500
13800
14100
14400
14700
15000
15300
15600
15900
16200
16500
16800
17100
17400
17700
18000

14.91
13.53
12.32
11.28
10.36
9.54
8.82
8.18
7.61
7.09
6.63
6.21
5.82
5.48
5.16
4.87
4.60
4.36
4.13
3.92
3.73
3.55
3.38
3.23
3.08
2.95
2.82
2.70
2.59
2.48
2.39
2.29
2.21
2.12
2.05
1.97
1.90
1.84
1.77
1.71
1.66

14.91
13.53
12.32
11.28
10.36
9.54
8.82
8.18
7.61
7.09
6.63
6.21
5.82
5.48
5.16
4.87
4.60
4.36
4.13
3.92
3.73
3.55
3.38
3.23
3.08
2.95
2.82
2.70
2.59
2.48
2.39
2.29
2.21
2.12
2.05
1.97
1.90
1.84
1.77
1.71
1.66

14.91
13.53
12.32
11.28
10.36
9.54
8.82
8.18
7.61
7.09
6.63
6.21
5.82
5.48
5.16
4.87
4.60
4.36
4.13
3.92
3.73
3.55
3.38
3.23
3.08
2.95
2.82
2.70
2.59
2.48
2.39
2.29
2.21
2.12
2.05
1.97
1.90
1.84
1.77
1.71
1.66

14.91
13.53
12.32
11.28
10.36
9.54
8.82
8.18
7.61
7.09
6.63
6.21
5.82
5.48
5.16
4.87
4.60
4.36
4.13
3.92
3.73
3.55
3.38
3.23
3.08
2.95
2.82
2.70
2.59
2.48
2.39
2.29
2.21
2.12
2.05
1.97
1.90
1.84
1.77
1.71
1.66

14.91
13.53
12.32
11.28
10.36
9.54
8.82
8.18
7.61
7.09
6.63
6.21
5.82
5.48
5.16
4.87
4.60
4.36
4.13
3.92
3.73
3.55
3.38
3.23
3.08
2.95
2.82
2.70
2.59
2.48
2.39
2.29
2.21
2.12
2.05
1.97
1.90
1.84
1.77
1.71
1.66

22.49
19.43
16.90
14.79
13.02
11.52
10.24
9.14
8.20
7.38
6.66
6.04
5.49
5.01
4.58
4.20
3.86
3.55
3.28
3.03
2.81
2.61
2.43
2.26
2.11
1.97
1.85
1.73
1.63
1.53
1.44
1.36
1.28
1.21
1.14
1.08
1.02
0.97
0.92
0.88
0.83

NOTES:
1. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method
2. Following values of Fy considered for calculating the ultimate loads

1.0 mm BMT Grade AS1397/G550 Z350 - Fy = 550 Mpa


1.2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa
1.5,1.9,2.4,3.0 mm BMT Grade AS1397/G450 Z350 - Fy = 450 Mpa
3. The loads have been based on the use of approved Metroll sections & bridging
systems.
4. The BOLD HORIZONTAL LINE marks where the overall length of the sections exceeds
the normal delivery length (12000 mm nominal).
5. IN = Inward load capacity.
OUT = outward load capacity.
DEF. = Load required to give a deflection of SPAN/150

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

ate method

exceeds

Das könnte Ihnen auch gefallen