Weiber Plant Growth Chambers are designed to study the effect of described different environmental factors such as humidity, temperature and light in various application tests on the growth of plants. Plant growth and geographic distribution are greatly affected by the environment. If any environmental factor is less than ideal, it limits a plant's growth and/or distribution. For example, only plants adapted to limited amounts of water can live in deserts. Either directly or indirectly, most plant problems are caused by environmental stress. In some cases, poor environmental conditions (e.g., too little water) damage a plant directly. In other cases, environmental stress weakens a plant and makes it more susceptible to disease or insect attack.

TECHNOCRACY PVT. LTD.

ENVIRONMENTAL FACTORS THAT AFFECT PLANT GROWTH INCLUDE

Temperature: is a measure of the intensity of heat. Plant growth occurs in a fairly narrow range - 60 - 100 degrees F. Temperature directly affects the processes of photosynthesis, respiration transpiration and absorption of water and nutrients.

Moisture supply: Plant growth is restricted by low and high levels of soil moisture as good soil moisture improves nutrient uptake. If moisture is a limiting factor fertilizer is not used efficiently.

Radiant energy: quality, intensity and duration (photoperiodism) of light are important for the plant growth.

Photoperiodism is defined as the behavior of plant in relation to length of the day. On the basis of day period the plants can be: 1. Long day plants Flowering occur only if days are longer than same critical period - 12 hours e.g. Grains and clovers 2. Short day plants flowering occur only if days are shorter than critical period e.g. soybeans. 3. Indeterminate flowering occur over a wide range of day lengths. E.g. Tomato, cotton,buckwheat

Composition of the atmosphere: plant growth majorly depends on the amounts of gases present in the atmosphere such as carbon dioxide, nitrogen etc.

Soil aeration and soil structure: Compact soils of high bulk density and poor structure are aerated poorly. Pore space is occupied by air and water so the amount of air and water are inversely proportional to the amount of oxygen in the soil. On well drained soils, oxygen content is not likely to be limiting to plant growth.

With a basic understanding of these factors, one (researcher/student) may be able to manipulate plants to meet required needs, whether for increased leaf, flower, or fruit production. By recognizing the roles of these factors, personnel also will be better able to diagnose plant problems caused by environmental stress.

CONSTRUCTION
Chamber body: Double walled heated and convection unit, with the outer rust proofing wall made up powder coated PCRC sheets and inner wall made up of stainless steel of grade 304.

Insulation: is a method of retardation for the flow of heat, this process reduce the heat loss or gain for energy conservation thus saving the energy. Weiber thermal shock chamber provides insulation either through fibrous insulation i.e. mineral glass wool or through cellular insulation i.e. polyurethane foam (PUF).

TECHNOCRACY PVT. LTD.

Fibrous Insulation: Composed of air finely divided into interstices by small diameter fibers usually chemically or mechanically bonded and formed into boards, blankets, and hollow cylinders.

Cellular Insulation: Composed of air or some other gas contained within a foam of stable small bubbles and formed into boards, blankets, or hollow cylinders.

Heating: Desired positive temperature is provided through stainless steel sheathed air heaters, these heaters do not affect the test specimen directly as they are placed in conditioning plenum proving indirect heat.

Air Circulation: Air circulation efficient motor fans are provided, ensuring uniform temperature throughout the chamber.

Cooling: Negative temperature is maintained through ultra low temperature application compressor and non CFC eco friendly R 404a refrigerant used.

Refrigeration: It is provided through hermetic and half-hermetic compressor cascade refrigeration system. Hermetic compressor is completely sealed, especially against the escape or entry of air and semi-hermetic compressor is partially sealed units and these units are mainly utilizes for real refrigeration work.

SALIENT FEATURES

Reliable Aesthetically designed. Corrosion Resistant Energy Efficient CFC free cooling RS 232C interface

APPLICATIONS

Production of biotherapeutic proteins Germplasm containments

TECHNOCRACY PVT. LTD.

Biotechnology Agriculture Tissue Culture Applications Enzyme reaction applications Fermentation analysis

TECHNICAL SPECIFICATION

Temperature Range

5 Degree to 50 degree Centigrade (without irradiation) and 10 Degree to 50 Degree Centigrade (with irradiation)

Temperature Sensor

PT 100

Co2 range

300-5,000 ppm

Co2 Sensor

Non dispersive infrared (NDIR) gas sensors, it is a highly integrated analysis system for monitoring respiratory carbon dioxide concentration.

Humidit

20% to 80% relative humidity

Temperature Control

The temperature is efficiently controlled by PLC based HMI interactive control panel

TECHNOCRACY PVT. LTD.

An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products

www.acmasindia.com | www.cleanroom-equipments.com | www.test-chambers.com

TECHNOCRACY PVT. LTD.


SALES OFFICE (INDIA)
Office no. 506 & 507, 5th Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com

SALES OFFICE (HONG KONG)


Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: hk@acmasindia.com

SHOWROOM
J-284 Sector 1 Bawana Industrial Estate, Bawana, Delhi, INDIA-110039 Tel.: 0091-0-9312219738 (M) +91- 9717741167 E-mail.: info@acmasindia.com

SALES OFFICE (RUSSIA) Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia
E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com

Das könnte Ihnen auch gefallen