GENERAL CATALOGUE
Heat pumps - Inertial puffers - Indirect cylinders - Water Heaters
Contents
Heat pumps
> wall-hung > floor standing > floor standing with coil > accessories & kit for heat pump series 80-100 series 180-300 series 300
4
5 6 8 10
Inox
> wall-mount electric water-heaters rapid series 10 series 65 series 50-80-100 series 120-160-200-300-400-500 series 800-1000 series 120-160-200-300-400-500 series 800-1000 > vertical wall-mount electric water heaters > vertical wall-mount electric water heaters > floor standing electric water heaters > floor standing electric water-heaters high storage > indirect cylinders single and double coil > indirect cylinders single and double coil high storage > accessories & kit for inox
11
12 13 13 14 15 16 18 20
Indirect cylinders
> circular undermount > rectangular undermount > elliptical increased size coil > single and double coil > single and double coil high storage > multiposition > accessories & kit for indirect cylinder series 115-150 series 120-160 series 300-400-500 series 120-160-200-300-400-500-600 series 800-1000 series 80-100-115-150-200-300
21
22 23 24 26 28 30 31
Inertial puffers
> puffer > tank in tank series 200-300-400-500-600-800-1000 series 600-750-900
33
34 36
Contents
Gas water heater
> wall-hung natural draught > wall-hung Fan flue > floor standing natural draught small storage > floor standing natural draught medium storage > floor standing natural draught high storage > floor standing fan flue > accessories & kit for gas water heaters series 50-80-100-120 series 80-120 series 115-150-200 series 300-500 series 600-800-1000-1500-2000 series 220-300-400
39
40 41 42 43 44 45 46
47
48 49 49 50 52 53 54 55 56 56 57 58 59 60
61
62
Heat pumps
The System
The heart of the System is an indirect cylinder with a built-in heat pump that enables the simultaneous or selective use of up to four different energy sources: 1) thermal energy; 2) electricity; 3) solar power; 4) environmental energy. The heat pump is designed to transfer heat from a body at a lower temperature to another body at a higher temperature. This process is the opposite of what happens in nature, and is due to the fact that electricity is supplied to the appliance that heat pumps. The operating principle of the heat pump is a thermodynamic cycle opposite to refrigeration. The efficiency of a heat pump is represented by its performance coefficient COP, which is the ratio of the heat output yielded to the electrical power utilised.
The strengths
The features that make this system worthwhile are multiple, but the most obvious advantage is that it is an intrinsically efficient system. It has direct repercussions on the amortisation of the installation cost and on the consumers utility bills too. Moreover, using a heat pump enables the exploitation of portions of energy which would otherwise be wasted (such as in installations in boiler rooms). Lastly, this system also provides an easy and convenient integration with other renewable energy sources (solar panels, wood-fired boilers, etc.). Heat pumps are ideally installed in cellars or damp rooms because the humidity in the air is removed during operation (dehumidifying effect).
Danfoss Compressor Thermostatcontrolled valve
Operating principle
The heat pump comprises a closed circuit made up of a compressor, a condenser, a lamination valve and an evaporator through which the heat transfer fluid flows. The thermodynamic cycle the fluid experiences consists in an adiabatic compression, a condensation phase, an expansion phase and also evaporation. During compression, the pressure and temperature of the fluid rise, during the second stage the fluid flows through a heat exchanger (condenser) where it comes into contact with domestic water, to which it yields heat. During the third stage, the fluid flows through an expansion valve (lamination process) and its pressure and temperature consequently drop. During the last stage, referred to as evaporation, the fluid switches from its liquid state to gas: the coolant is at very low temperatures, which enable it to absorb heat from the external heat transfer fluid. So during the operation of the heat pump, the following occurs: electricity is consumed in the compressor, heat is absorbed from the external environment (evaporator) and heat is yielded in the condenser to the liquid that needs to be heated. The advantage of a heat pump lies in the fact that more energy is supplied in the form of heat than the electricity required for its operation.
Evaporator
Filter
ELECTRICITY SUPPLY
1/3 of energy
EVAPORATOR
Absorption of heat from the outside
CONDENSER
Yielding of heat to the domestic water
2/3 of energy
LAMINATION VALVE
3/3 of energy
Honeycomb grid
Control panel
wall-hung
heat pump
Futura
serieS 80-100
new
Compact system for heating sanitary water by using an air-to-water heat pump. The system utilises renewable energy. It is one of the most interesting products to be used for decreasing the fuel consumption and protecting the environment. Thanks to its small dimensions, equal to a normal water heater, and to its easy installation, the new heat pump (from 80L to 120L) is intended for domestic use. Just plug it in, like a normal water heater, and it is ready.
Steel tank, glass-lined using the flow-coating method (850 C). Corrosion-proof magnesium anode. External casing made of sheet metal coated with (white) epoxy powder paint. CFC and HCFC-free, 37 mm average polyurethane (PU) foam insulation layer. Hydraulic connections located in the lower part. Brackets for wall-mounting.
1,2 kW integrated electric heating element. Electronic control panel with display indicating temperature, indicator light for heat pump operation and electric resistance. Switch to activate the different modes of operation: Turbo, Bath, Comfort. Ecological refrigerant fluid R134a; Rotary compressor for maximum noiseless Axial fan Powerful fin type evaporator.
V~/Hz/A
230/50/16 230/50/16
-/kg
R134a/0,28 R134a/0,28
kW
0,31 0,31 Maximum operating pressure Net weight
kW
1,20 1,20 Hydraulic connections
kW
0,90 0,90 A
kW
2,41 2,41 B
C
65 65
MPa
0,80 0,80
kg
50 56
KW-WW
R 1/2 R 1/2
mm
1142 1355
mm
392 605
470
480
544
431 B
60 206
KW 100
WW
of electricity
stand alone
heat pump
Heat pumps
series 180-300
Domestic water heating system with air-water heat pump. The system envisages the use of renewable energy and the possible integration with other energy sources such as electricity. Recommended for domestic and collective use.
Steel tank, glass-lined using the flow-coating method (850 C). 134 mm front inspection hatch integrated with tinned copper condenser. Corrosion-proof magnesium anode. Hydraulic connections located on the rear. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. External plastic (PVC) coating. Adjustable feet for floor standing. Environmentally-friendly gas R 134a. 1.5 kW 230V~ electric heating element. Control panel complete with switch with indicator light for heat pump and heating element operation, regulation thermostat, thermometer and signal indicators. High and low pressure safety devices. DANFOSS compressor for super silent operation. EBM 650 m3/h axial fan.
Accessories on page 10
l HP 180 HP 300
180 300
V~/Hz/A
230/50/16 230/50/16
-/kg
R134a/0,85 R134a/0,85
kW
0,62 0,62
kW
2,12 2,12
kW
1,91 1,98
kW
1,50 1,50
Range of use
Net weight
Hydraulic fittings
Recirculation fittings
kW HP 180 HP 300
3,41 3,48
C
2956 2956
C
835 835
dB (A)
61 61
C
55 55
C
65 65
MPa
1,0 1,0
kg
95 109
KW-WW
Rp 1 Rp 1
Z
Rp 1 Rp 1
Data compliant with EN 255-3 (WPZ B-002-04-07 Wrmepumpentestzentrum NTB - FWS CH-Buchs)*
Coefficient of performance Max. qty individual flow rate at 40 C V max Max. actual power absorbed Pes Heating time th C D E F
HP 180 HP 300
COPt
3,1 3,2
I
283 448
W
36 44
h:min
4:56 7:57
mm
1412 1852
mm
142 142
mm
612 912
mm
922 1362
Note: * Room air temp. 15C, humidity 71%, domestic water at 15 C / temperature in storage tank 55 C
heat pump
650
713
WW
F E
KW
650
713
WW
KW
heat pump
Heat pumps
seriEs 300
Domestic water heating system with air-water heat pump. The system envisages the use of renewable energy and the possible integration with other energy sources such as electricity, thermal energy and solar power. Recommended for domestic and collective use.
Steel tank, glass-lined using the flow-coating method (850 C). 134 mm front inspection hatch integrated with tinned copper condenser. Single coil (for W version) and double coil (for WW version), optimised for maximum heat exchange and minimum limescale build-up. Sensor fittings, (one for W version) (two for WW version). Corrosion-proof magnesium anode. Hydraulic connections located on the rear. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. External plastic (PVC) coating. Adjustable feet for floor standing. Environmentally-friendly gas R 134a. 1.5 kW 230V~ electric heating element. Control panel complete with switch with indicator light for heat pump and heating element operation, regulation thermostat, thermometer and signal indicators. High and low pressure safety devices. DANFOSS compressor for super silent operation. EBM 650 m3/h axial fan.
Accessories on page 10
1-2 Coil
Capacity Power supply Coolant/average Absorption Max. nominal recharge (heat pump only)* absorption Power output Electric heating (heat pump only)* element (integration) Maximum power output Range of hot water temp. setting Range of use
l HP 300 W HP 300 WW
300 300 Maximum noise level
V~/Hz/A
230/50/16 230/50/16 top/bot. coil surface
-/kg
R134a/0,85 R134a/0,85
kW
0,62 0,62
kW
2,12 2,12
kW
1,91 1,91
kW
1,50 1,50
kW
3,41 3,41 Hydraulic fittings
C
2956 2957
C
835 835
Primary Max. temperature Max. temperature Max. operating Net flow rate (heat pump only) (with electric heating element) pressure weight
m
1,30/1,30/0,80
kW
37/37/26
m/h
2,50 2,50
C
55 55
C
65 65
MPa
1,0 1,0
kg
130 145
KW-WW
Rp 1 Rp 1
PV-PR
Rp 1 Rp 1
Z
Rp 1 Rp 1
Tr
1 2
Data compliant with EN 255-3 (WPZ B-002-04-07 Wrmepumpentestzentrum NTB - FWS CH-Buchs)*
Coefficient of performance Max. qty individual flow rate at 40 C V max Max. actual power absorbed Pes Heating time th C D E F
I
430 430
W
43 55
h:min
7:51 8:01
mm
mm
mm
mm
Note: * room air temp. 15 C, 71% humidity, domestic water at 15 C / temperature in storage tank 55 C
heat pump
300 W
WW WW
1852 1852
Tr Tr
PR PR
KW KW
Tr Tr
300 WW
WW
Tr 1852
PV2
Z
Tr
Tr
Tr
heat pump
KIT diagram
Suction Delivery
Suction KIT
Delivery KIT
10
Line Inox
Thanks to its range including electric storage water heaters and stainless steel indirect cylinders, STYLEBOILER offers complete solutions for the production of hot water with a capacity included between 10 and 1000 litres and powers included between 1.2 and 10 kW with single and three-phase connections. The range meets the domestic needs, but it can also be suitable for communal settings. The product lines range from the small line, which is ideal for producing small quantities of water in a rapid and cheap way, to the easy mediumsize water heaters, up to the extra line, which supplies the most advanced technology to be found on the market. Interline and Free Standing lines are the best way to meet the needs of huge quantities of hot domestic water and also meet the highest quality expectations in compliance with European and international standards.
IP protection level
The Correx system is the latest technology in terms of active tank protection, and is fitted with a PCB, a control LED and a transmitted current titanium anode. This system solves all your anode-replacement and limescale removal problems.
Styleboilers water heaters are safe because they stand water jets and can be installed close to the supply points, also in public spaces and communities.
Double safety
It is manufactured with very thick and highdensity polyurethane foam (PU) (Interline range) to assure excellent thermal insulation.
It is achieved by using an operation thermostat and an over-temperature thermostat to prevent possible malfunctions.
Magnesium anode
It is to be found in all products within the range and makes the boilers electrochemical protection constantly effective.
Styleboiler undertakes streamlining the industrial activities in the respect of the environment. In order to reduce the environmental impact to the minimum, it eliminated the hydrofluorocarbons (CFC-HCFC) from the insulation (PU) layer and always pays great attention to the recyclability of the components.
11
Small inox
series 10
Wall-mounted electric storage water heaters are designed for producing small quantities of water in a rapid and cheap way, as well as to meet the new expectations as to durability and perfection. The inox stainless steel product line has been created for this purpose; this line supplies maximum quality and durability thanks to the use of special materials, such as stainless steel and sophisticated technological solutions, such as TIG and Microplasma welding. They can be installed above and under the sink.
AISI 316L stainless steel boiler, welded with TIG and Microplasma technology. AISI 321 stainless steel heating element. Corrosion-proof magnesium anode. Stem safety and adjustment thermostat. Insulation layer with polystyrene (EPS) shells to minimise heat loss.
Shell and back made with shockresistant polypropylene (PP). Wall-mount by using the specific brackets. Indicator light. IPX5 protective cover over electrical parts. Nylon dielectric circuit breakers on the hydraulic fittings.
Capacity Capacity
Power
Voltage
Net Weight
Hydraulic fittings
kW
1,2 1,2
V~
230 230
min
30 30
C
75 75
MPa
0,8 0,8
kg
4,6 4,6
KW-WW
R R
oversink version 10
undersink version 10
261
251
KW
100
WW
189
62
450
KW
WW
228
100
189
62
450
250
261
251
12
Easy inox
450
series 65
475
450
475
The wall-mounted electric storage water heater represents the basic range that combines great functionality, high efficiency and maximum quality.
AISI 316L stainless steel boiler, welded with TIG and Microplasma technology. Corrosion-proof magnesium anode. AISI 321 stainless steel threaded heating element on 1 sleeve. Capillary safety and internal regulation thermostat. Indicator light. CFC and HCFC-free, very thick expanded 112 polyurethane (PU) insulation layer. External casing made of sheet metal coated with epoxy powder paint. IPX5 protective cover over electrical parts. Stored water temperature indicator. Nylon dielectric circuit breakers on the hydraulic fittings.
648
648
270
424
270
KW
WW
100 KW
WW
424
100
112
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
l SSWVX65
65
kW
1,2
V~
230
min
198
C
75
MPa
0,8
kg
15,50
KW-WW
R
series 50-80-100
450 450 475 475
eXtra inox
Stainless steel wall-hung electric storage water heaters are designed to meet the new expectations as to durability and perfection. To this end, the inox (stainless steel) product line was introduced, providing maximum quality and durability owing to the use of special materials such as stainless steel and sophisticated technological solutions such as TIG and Microplasma welding.
Aisi 316L stainless steel tank welded with TIG and Microplasma technology. Tank inspection flange. Correx electronic protection device with titanium anode and signalling LED. Incoloy 800 stainless steel heating element fitted on a flange. External regulation and safety capillary thermostat. 112 LED indicator light. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. IPX5 protective cover over electrical parts complete with cable and plug. Stored water temperature indicator. Nylon dielectric circuit breakers on the hydraulic fittings.
270
270 B B
KW
KW
WW
WW
100
100
112
Heat. Max. Insul. Heat loss oper. time t=50C Thickness 65C temp.
kW
1,5 1,5 1,5
V~
230 230 230
min
123 196 245
mm
25 25 25
kWh/24h
0,87 1,13 1,30
C
75 75 75
MPa
0,8 0,8 0,8
kg
14,0 18,5 23,5
KW-WW
R R R
mm
mm
13
floor-standing storage
Interline inox
series 120-160-200-300-400-500
Stainless steel floor-standing electric storage water heaters are designed to meet the new expectations as to durability and perfection. To this end, the inox (stainless steel) product line was introduced, providing maximum quality and durability owing to the use of special materials such as stainless steel and sophisticated technological solutions such as TIG and Plasma welding. The insulation layer is made of very thick high-density polyurethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use.
Aisi 316L stainless steel tank welded with TIG and Plasma technology. 134 mm front inspection hatch. 134 mm flange on the top of the tank complete with counter flange. Correx electronic protection device with titanium anode and signalling LED. Three-part incoloy 800 stainless steel heating element. Regulation and safety capillary thermostat. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. External coloured plastic (PVC) coating. Adjustable feet for floor standing. Stored water temperature indicator.
Accessories on page 20
Capacity
Power
Voltage
Insul. Thickness
Net Weight
Hydraulic fittings
Recirculation
l ISSX 120 ISSX 160 ISSX 200 ISSX 300/3 ISSX 400/3 ISSX 500/3
120 160 200 300 400 500
kW
1,5 2,0 2,0 4,0 8,0 10,0
V~
230 230 230 400/3 400/3 400/3
min
294 294 367 275 184 184
mm
50 50 50 50 50 50
kWh/24h
1,50 1,70 2,00 2,40 2,80 3,30
C
75 75 75 75 75 75
MPa
1,0 1,0 1,0 1,0 1,0 1,0
kg
33 37 42 69 74 84
KW-WW
Rp Rp Rp Rp 1 Rp 1 Rp 1
Z
Rp Rp Rp Rp 1 Rp 1 Rp 1
mm
mm
mm
833 1018 1290 1526 1530 1796
mm
mm
mm
608 793
610 654 610 654 610 654 650 698 750 798 750 798
213 618 1065 228 803 1283 263 763 1248 263 913 1513
A
WW
E
KW
F 14 D
AISI 316L stainless steel boiler, welded with TIG and Plasma technology. Double 134 mm front hatchway for electrical Kit assembly and inspection. 134 mm top bottom-flange complete with counter-flange and probe pipe.
Very thick expanded polyurethane (PU) / (EPS) insulation layer. Easy entry system. External coloured plastic coating. Adjustable feet for floor standing. Stored water temperature indicator.
Accessories on page 20
Capacity Capacty
Insul. Thickness
Net Weight
Hydraulic fittings
Recirculation fittings
C
75 75
MPa
1,0 1,0
kg
146 170
KW-WW
Rp 1 Rp 1
Z
Rp 1 Rp 1
mm
880 880
mm
925 925
mm
1865 2245
mm
320 320
mm
982 1165
mm
1580 1960
A
WW
KW
15
high storage
Free Standing
Stainless steel double coil storage indirect cylinders are made using technologies that guarantee maximum quality and durability owing to the use of special materials and sophisticated technological solutions such as TIG and Plasma welding. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted with further integration systems. Recommended for industrial and collective use.
Aisi 316L stainless steel tank welded with TIG and Plasma technology. 134 mm front inspection hatch. 134 mm top inspection flange complete with counter flange and sensor sheath (Tr). Corrosion-proof magnesium anode. Lowered coil to optimise the heat exchange process and limit the formation of limescale. Hydraulic connections located on the rear. External coloured plastic (PVC) coating. Recirculation fitting. Stored water temperature indicator. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. Adjustable feet for floor standing. Integration KITS available for use with incoloy 800 stainless steel heating elements of up to 10 kW with single and three-phase connection. Version fitted with Correx electronic protection device with titanium anode and signalling LED available upon request.
Accessories on page 20
1 Coil
ISSWX 120 ISSWX 160 ISSWX 200 ISSWX 300 ISSWX 400 ISSWX 500
Series 120-160-200-300-400-500
Capacity Heat exchange surface Power (t 35)* D.H.W. production (t 35 k)* Heating time (t 35k)* Flow resistance Primary flow rate Insulation thickness Heat loss 65 C
l
120 160 200 300 400 500 Max. operating temperature
m
0,60 0,80 1,00 1,40 2,00 2,40 Max. operating pressure
kW
27,0 36,5 40,5 59,0 81,0 91,0 Net Weight 38 43 51 87 93 110
l/h
663 896 995 1460 1989 2229 Hydraulic fittings
min
11 11 13 13 13 14 Exchanger fittings Rp Rp Rp Rp 1 Rp 1 Rp 1
mbar
115 117 178 140 183 235 Recirculation fittings Rp Rp Rp Rp 1 Rp 1 Rp 1 A 610 610 610 650 750 750 B 654 654 654 698 798 798
m/h
2,0 2,0 2,0 3,0 3,0 3,0 C 833 1018 1290 1526 1530 1796 D 213 213 213 228 263 263
mm
50 50 50 50 50 50 E 323 323 323 338 373 373 F 443 518 618 803 763 913
kWh/24h
1,50 1,70 2,00 2,40 2,80 3,30 G 533 683 783 918 1063 1153 H 608 793 1065 1283 1248 1513
ISSWX 120 ISSWX 160 ISSWX 200 ISSWX 300 ISSWX 400 ISSWX 500
95 95 95 95 95 95
MPa
1,0 1,0 1,0 1,0 1,0 1,0
kg
KW-WW
Rp Rp Rp Rp 1 Rp 1 Rp 1
PV-PR
mm
mm
mm
mm
mm
mm
mm
mm
2 Coils
Capacity
Series 300-400-500
Coil position Surface change Power (t 35)* D.H.W. production (t 35 k)* Heating time (t 35k)* Flow resistance Primary flow rate Insulation thickness Heat loss 65 C
sup/inf
sup. inf. sup. inf. sup. inf.
m
0,80 1,30 0,80 1,60 0,80 2,10 Net Weight
kW
41 59 41 65 41 81 Hydraulic fittings
l/h
1006 1460 1006 1605 1006 1989 Exchanger fittings
min
19 13 25 16 31 16 Recirculation fittings A B
mbar
130 140 130 147 130 183 C D
m/h
3,0 3,0 3,0 E F
mm
50 50 50 G H
kWh/24h
2,40 2,80 3,30 L M
C
95 95 95
MPa
1,0 1,0 1,0
kg
93 100 114
KW-WW
Rp 1 Rp 1 Rp 1
PV-PR
Rp 1 Rp 1 Rp 1
Z
Rp 1 Rp 1 Rp 1
mm
650 750 750
mm
698 798 798
mm
1526 1530 1796
mm
228 263 263
mm
320 355 355
mm
688 695 855
mm
mm
mm
mm
843 969 1191 1283 848 971 1156 1248 1043 1208 1393 1513
Note: *Primary circuit temperature 80C / Secondary circuit temperature 10 /45C / Primary flow rate indicated in the table -D.H.W. = domestic hot water. top = coil at the top;-bot. = coil at the bottom
16
Tr
WW
PV
Z
PR E
KW
110 100 90 80 70 60 50 40 30 20 10
ISSWX 120 ISSWX 160 ISSWX 200 ISSWX 300 ISSWX 400 ISSWX 500
kW
Power kW
110 100 90 80 70 60 50 40 30 20 10 700 650 600 550 500 450 400 350 300 250 200 150 100 50 0
1,0
2 ,0
3 ,0
4 ,0
5 ,0
ISSWX 120 ISSWX 160 ISSWX 200 ISSWX 300 ISSWX 400 ISSWX 500
kW
1,0
2 ,0
3 ,0
4 ,0
5 ,0
mbar
1,0
2 ,0
3 ,0
4 ,0
5 ,0
Flow rate m /h
Flow rate m /h
700 650 600 550 500 450 400 350 300 250 200 150 100 50 0
ISSWX 120 ISSWX 160 ISSWX 200 ISSWX 300 ISSWX 400 ISSWX 500
1,0
2 ,0
3 ,0
4 ,0
PV1 5 ,0
PR1 KW
1 05 1 00 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 1 5 1 0
mbar
kW
ISSWWX 300-500 sup. ISSWWX 300 inf. ISSWWX 400 inf. ISSWWX 500 inf.
H G
1, 0
2, 0
3, 0
4, 0
5, 0
Power kW
1 05 1 00 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 1 5 1 0
kW
mbar
ISSWWX 300 inf. 300 bot. ISSWWX 400 inf. 400 bot. ISSWWX 500 inf. 500 bot.
300-500 top. 300-500 sup. ISSWWX 300 bot. ISSWWX 300 inf.
ISSWWX 400 inf. 400 bot ISSWWX 500 inf. 500 bot.
1, 0
2, 0
3, 0
4, 0
5, 0
1, 0
2,0
3, 0
4,0
5,0
Flow rate m /h
Portata m
Flow rate m /h
Perdite di carico
500 450 400 350
17
AISI 316L stainless steel boiler, welded with TIG and Plasma technology. Double 134 mm front hatchway for electrical Kit assembly and inspection. 134 mm top bottom-flange complete with counter-flange and probe pipe. Exchangers with lowered turns to streamline the heat exchange and reduce the formation of limescale.
Very thick expanded polyurethane (PU) / (EPS) insulation layer. Easy entry system. External coloured plastic coating. Adjustable feet for floor standing. Stored water temperature indicator. They are available in electrical integration kits with the use of Incoloy 800 stainless steel heating elements up to 10 kW with single- and threephase connections.
Accessories on page 20
1 Coil
ISSWX 800 ISSWX 1000
Series 800-1000
Capacity Average insul. layer thickness Heat exchange surface Power (t 35 K)* D.H.W. time production Heating (t 35 K)* (t 35 K)* Primary flow rate Max. operating temp. Max. operating pressure Net Weight Hydraulic fittings Exchanger fittings Recirculation fittings
l
800 1000
mm
>100 >100
m
3,05 3,55
kW
110 130
l/h
2703 3194
min
18 19
m/h
3,0 3,0
C
95 95
MPa
1,0 1,0
kg
195 226
KW-WW
Rp 1 Rp 1
PV-PR
Rp 1 Rp 1
Z
Rp 1 Rp 1
* Note: Primary temperature 80C / Secondary input temperature 10/45C / Primary capacity specified in the table - D.H.W. = Production of domestic hot water.
2 Coils
Capacity
Series 800-1000
Average insul. layer thickness Heat exchange surface Power (t 35 K)* D.H.W. production (t 35 K)* Heating time (t 35 K)* Primary flow rate Max. operating temp. Max. operating pressure Net Weight Hydraulic fittings Exchanger fittings Exchanger Recirculation fittings fittings
mm
>100
sup/inf
sup. inf. sup. inf.
m
1,30 3,05 1,30 3,55
kW
59 110 59 130
l/h
1460 2703 1460 3194
min
13 18 13 19
m/h
3,0
C
95
MPa
1,0
kg
206
KW-WW
Rp 1
PV-PR
Rp 1
Z
Rp 1
1000
>100
3,0
95
1,0
237
Rp 1
Rp 1
Rp 1
* Note: Primary temperature 80C / Secondary input temperature 10/45C / Primary capacity specified in the table - D.H.W. = Production of domestic hot water
18
WW
PV Z
H G F
PR KW
A
WW PV2 PR2 Z PV1
C M L F
PR1 KW
E D
D E
mm
925 925
mm
1865 2245
mm
320 320
mm
425 425
mm
982 1165
mm
1187 1303
mm
1580 1960
mm
925
mm
1865
mm
320
mm
425
mm
985
mm
1090
mm
1178
mm
1475
mm
1580
880
925
2245
320
425
1187
1340
1578
1855
1960
19
071079
11/4 3,0 kW 230 V- single-phase electrical kit formed by: 11/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection
070137
3.06.0 kW 400/3V THREE-PHASE INOX ELECTRICAL KIT RECOMMENDED FOR SERIES 160-200-300 formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. 4.08.0 kW 400/3 V THREE-PHASE INOX ELECTRICAL KIT RECOMMENDED FOR SERIES 400-500-600-800-1000 formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. 5.010.0 kW 400/3 V THREE-PHASE INOX ELECTRICAL KIT RECOMMENDED FOR SERIES 400-500-600-800-1000 formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket.
070138
070136
20
Indirect cylinders
This range of indirect cylinders performs indirect heating via one or two fixed coils or by means of an air casing with extensive heat exchange surfaces. They provide an easy and abundant supply of hot water for all uses. They can be connected to both independent and central heating systems, or to remote heating systems or they can be used in forced flow solar-powered systems, providing high heat exchange efficiency levels. The range of capacities covered by this product line is from 115 to 1000 litres with power ratings of between 20 kW and over 100 kW of heat output. The models available include undermount appliances to be fitted below the boiler, which are ideally combined with any wall-hung boiler for the production of large quantities of hot water in a limited amount of space, along with the multi-purpose free standing versions which comprise single and double coil indirect cylinders, designed to integrate several types of energy available, from methane gas via a gas boiler, to electrical installations using the integration kit available, and even solar energy systems with the forced flow solar-powered systems. The line of indirect cylinders is completed with the multi-position air casing version which has a distinguishing trait: its versatility, which makes both vertical and horizontal as well as floor-standing installations possible.
Magnesium anode
Featured in all the models in the range, this anode makes for effective electrochemical tank protection.
Environmentally friendly
Thanks to the flow-coating enamelling process at 850C for guaranteed quality internal protection.
Styleboiler strives to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recyclable components.
21
Undermount
series 115-150
Vertical storage single coil indirect cylinders are designed to be combined with any wall-hung boiler for the production of large quantities of hot water despite space restrictions. They are recommended for domestic use.
Steel tank, glass-lined using the flow-coating method (850 C). 134 mm top inspection flange complete with counter flange and sensor sheath (Tr). Corrosion-proof magnesium anode. Lowered coil to optimise the heat exchange process and limit the formation of limescale. Recirculation and outlet fittings. External casing made of sheet metal coated with epoxy powder paint. Hydraulic fittings at the top to facilitate connections with the wall-hung boiler. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. Feet for floor standing. Stored water temperature indicator.
Capacity Capacity
Power (T 35 k)*
Flow resistance
Insulation thickness
Heat loss 65 C
l
115 150 Max. operating temperature
m
0,90 1,00 Max. operating pressure
kW
27 30 Net Weight
l/h
663 732 Hydraulic fittings
min
11 13 Exchanger fittings
mbar
189 219 Recirculation fittings
m/h
2,0 2,0 Outlet fitting
mm
35 35 A
kWh/24h
1,30 1,90
C
95 95
MPa
1,0 1,0
kg
53 61
KW-WW
R R
PV-PR
R R
Z
R R
E
Rp Rp
mm
862 1064
Note: *Primary circuit temperature 80C / Secondary circuit temperature 10 /45C / Primary flow rate indicated in the table -D.H.W. = domestic hot water.
570
WW
110
KW
Z 173,5 159 PV PR
45
Potenz
45
40 35
BSC 115 BSC 150
E
kW
30 25 20 15
Portata
Power kW
45 40 35
115 150
BSC 115
Potenza kW
900 750 600
Perdite di ca
mbar
kW
BSC 150
Flow rate m /h
Portata m/h
Flow rate m /h
Portata
22
bar
Undermount
series 120-160
Vertical single coil storage indirect cylinders are designed to be combined with any wall-hung boiler for the production of large quantities of hot water despite space restrictions. The rectangular shape can be suitably fitted as an undermount indirect cylinder. The coloured PVC coating enhances its lines and protects it against possible collisions during assembly operations and normal use. In addition, the product has been designed so that it can be completely disassembled at the end of its life cycle, in a way to allow its correct recycling and/or the disposal of its components. It is recommended for domestic use.
Steel tank, glass-lined using the powder method (850C). 134 mm top inspection flange complete with counter-flange and probe sheath (Tr). Corrosion-proof magnesium anode. Streamlined coil for the maximum heat exchange
Capacity Capacity
process and to reduce the formation of limescale. Outlet and recirculation fittings. Hydraulic fittings installed in the upper part to facilitate the connection with a wall-hung boiler. Self-extinguishing and very thick high-density (EPS) polystyrene-shell insulation
Heat exchange surface
layer. Anti-collision external coloured PVC coating. Adjustable feet for floor standing. Stored water temperature indicator. Drain cock.
Power (T 35 k)*
l
120 160 Max. operating temperature
m
1,15 1,20 Max. operating pressure
kW
32 32 Net weight
l/h
780 780 Hydraulic fittings
min
10 13 Exchanger fittings
mbar
170 172 Recirculation fittings
m/h
2,0 2,0 Outlet fitting
mm
>30 >30 A
MPa
1,0 1,0
kg
54 64
KW-WW
R R
PV-PR
R R
Z
R R
E
Rp Rp
mm
845 1045
* Note: Primary temperature 80C / Secondary inlet temperature 10/45C Primary capacity specified in the table - D.H.W. = Production of domestic hot.
561
561 120
270 120
270
PV WW Z PV KW PR Z WW
KW PR
200
149
100
576
Power kW
40 35 30
120 160
Potenza kW
40 35
ISSWT 120
576
Potenz
30
120 160
kW
kW
ISSWT 160
Flow rate m /h
Portata m3/h
Flow rate m /h
Portata
Perdite di ca
23
Big One
series 300-400-500
Indirect cylinders with increased size single fixed coil. They are designed for an easy and abundant supply of sanitary hot water by means of heat pumps. They can be connected with central heating systems and equipped with additional integration systems. They are recommended for collective use.
Steel tank, glass-lined using the flow-coating method (850 C). 134 mm front inspection hatch. 2 Corrosion-proof magnesium anode. High efficiency lowered coil designed to optimise the thermal exchange and to reduce limestone. Sensor sheath (Tr) located on the upper part. Hydraulic connections located on the rear. External coloured plastic (PVC) coating. Adjustable feet for floor standing.
CFC and HCFC-free thick polyurethane (PU) foam insulation layer. Stored water temperature indicator. Integration KITS available for use with tinned copper spiral heat exchangers or copper heating elements up to 5 kW and incoloy 800 stainless steel heating elements up to 10 kW with single and three-phase connection.
new
Capacity
Net weight
Power (t 35k)*
Pressure loss
m
3,8 4,5 5,5
mm
50 50 50
kWh/24h
2,4 2,8 3,3
C
95 95 95
MPa
1,0 1,0 1,0
kg
113 147 178
m/h
2 2 2
kW
84 87,5 88,7
l/h
1950 2050 2090
mbar
425 461 563
*Primary circuit temperature 80C / Secondary circuit temperature 10 /45C / Primary flow rate indicated in the table / DHW= domestic hot water
Hydraulic connections
Vent
N. of probes
PV-PR
Rp 1" Rp 1" Rp 1"
Z
Rp 1" Rp 1" Rp 1"
S
G 3/4" G 3/4" G 3/4"
Tr
1 1 1
mm
650 750 750
mm
675 775 775
mm
1560 1553 1818
mm
148 162 162
mm
338 388 391
mm
828 778 931
mm
1258 1228 1471
mm
1408 1386 1651
mm
1586 1576 1841
mm
170 190 190
24
100 90 80 70 60 50 40 30 20 10 0
kW
0,0
0,5
1,0
1,5
2,0
2,5
Power kW
100 90 80 70 60 50 40 30 20 10 0 800 700 600
300 400 500
500
mbar
kW
0,0
0,5
1,0
1,5
2,0
2,5
0,0
0,5
1,0
1,5
2,0
2,5
3,0
Flow rate m /h
Flow rate m /h
25
800
Free Standing
Single and double coil storage indirect cylinders use indirect heating. They provide an easy and abundant supply of hot water for all uses. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted with further integration systems. Recommended for industrial and collective use.
Steel tank, glass-lined using the flow-coating method (850 C). 134 mm front inspection hatch. Corrosion-proof magnesium anode. Double coil, optimised for maximum heat exchange and minimum limescale build-up. Three sensor sheaths (Tr) Stored water temperature located on the rear. indicator. Hydraulic connections Integration KITS available for located on the rear. use with tinned copper spiral Recirculation fitting. heat exchangers or copper CFC and HCFC-free very thick heating elements of up to 5 polyurethane (PU) foam kW and incoloy 800 stainless insulation layer. steel heating elements of up to 10 kW with single and External coloured plastic three-phase connection. (PVC) coating. Adjustable feet for floor Accessories on page standing. 31/32
1 Coil
ISSW 120 ISSW 160 ISSW 200 ISSW 300 ISSW 400 ISSW 500 ISSW 600
Series 120-160-200-300-400-500-600
Capacity Heat exchange surface Power (T 35 k)* D.H.W. production (T 35 k)* Heating time (T 35k)* Flow resistance Primary flow rate Insulation thickness Heat loss 65 C Max. operating temperature
l
120 160 200 300 400 500 600 Max. operating pressure
m
0,60 0,85 1,00 1,40 1,70 2,10 2,90 Net weight
kW
20 27 30 44 55 63 70 Hydraulic fittings
l/h
491 663 737 1081 1351 1543 1720 Exchanger fittings
min
15 15 17 18 19 20 31 Recirculation fittings No. of sensors
mbar
119 182 223 138 180 223 75 A B
m/h
2,0 2,0 2,0 3,0 3,0 3,0 3,0 C D
mm
50 50 50 50 50 50 50 E F
kWh/24h
1,50 1,70 2,00 2,40 2,80 3,30 3,60 G H
C
95 95 95 95 95 95 95 L M
ISSW 120 ISSW 160 ISSW 200 ISSW 300 ISSW 400 ISSW 500 ISSW 600
MPa
1,0 1,0 1,0 1,0 1,0 1,0 1,0
kg
45 57 66 97 123 144 220
KW-WW
Rp Rp Rp Rp 1 Rp 1 Rp 1 Rp 1
PV-PR
Rp Rp Rp Rp 1 Rp 1 Rp 1 Rp 1
Z
Rp Rp Rp Rp 1 Rp 1 Rp 1 Rp 1
Tr
2 2 2 2 2 2 2
mm
610 610 610 650 750 750 810
mm
620 620 620 675 775 775 832
mm
854 1056 1329 1560 1553 1818 1819
mm
150 150 150 148 162 162 124
mm
311 311 311 338 392 392 331
mm
414 416 486 538 560 554 456
mm
486 551 651 828 782 932 871
mm
571 701 801 978 932 1082 1161
mm
631 781 881 1058 1012 1162 1241
mm
720 922 1195 1408 1387 1652 1659
Note: *primary circuit temperature 80C / secondary circuit temperature 10 /45C / primary flow rate indicated in the table -D.H.W. = domestic hot water.
2 Coils
Capacity
Series 200-300-400-500-600
Coil position Heat exchange surface Power (T 35 k)* D.H.W. production (T 35 k)* Heating time (T 35k)* Flow resistance Primary flow rate Insulation thickness Heat loss 65 C Max. operating temp.
l ISSWW 200 ISSWW 300 ISSWW 400 ISSWW 500 ISSWW 600
200 300 400 500 600 Max. operating pressure
sup/inf
sup. inf. sup. inf. sup. inf. sup. inf. sup. inf. Net weight Hydraulic fittings
m
0,50 0,70 0,90 1,40 0,90 1,70 0,90 2,10 1,00 2,50
kW
22 25,5 31,5 44 31,5 55 31,5 63 34 68
l/h
541 627 774 1081 774 1351 774 1543 835 1671 No. of Sensors A B
min
23 21 24 18 33 19 41 20 45 23 C D
mbar
119 182 100 138 100 180 100 223 64 73 E F
m/h
2,0 3,0 3,0 3,0 3,0 G H
mm
50 50 50 50 50 L
kWh/24h
2,00 2,40 2,80 3,30 3,60 M N O
C
95 95 95 95 95 P
MPa ISSWW 200 ISSWW 300 ISSWW 400 ISSWW 500 ISSWW 600
1,0 1,0 1,0 1,0 1,0
kg
61 105 133 154 234
KW-WW
Rp Rp 1 Rp 1 Rp 1 Rp 1
PV-PR
Rp Rp 1 Rp 1 Rp 1 Rp 1
Z
Rp Rp 1 Rp 1 Rp 1 Rp 1
Tr
3 3 3 3 3
mm
610 650 750 750 808
mm
620 675 775 775 833
mm
1329 1560 1553 1818 1749
mm
150 148 162 162 123
mm
261 288 322 322 330
mm
336 378 402 437 435
mm
581 693 722 872 945
mm
mm
mm
mm
1041 1225 1177 1372 1452
mm
1108 1292 1259 1457 1527
mm
1195 1408 1387 1652 1658
661 747 841 773 859 956 800 879 977 972 1072 1172 1035 1110 1200
Note: *primary circuit temperature 80C / secondary circuit temperature 10 /45C / primary flow rate indicated in the table -D.H.W. = domestic hot water -top = coil at the top;-bot. = coil at the bottom
26
BSS 120 BSS 160 BSS 200 BSS 300 BSS 400 BSS 500 BSS 600
Power kW
85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 1,0 2,0 3,0 4,0 5,0 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 0 1,0
kW
Potenza kW
Pe
BSS 120 BSS 160 BSS 200 BSS 300 BSS 400 BSS 500 BSS 600
BSS 120 BSS 160 BSS 200 BSS 300 BSS 400 BSS 500 BSS 600
mbar
kW
2,0
Portata m/h
3,0
4,0
5,0
Flow rate m /h
Flow rate m /h
1,0
2,0
3,0
4,0
5,0
Tr Tr
PV1
kW
800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 0
B
80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 1,0
mbar
Tr
M L H G
O N
Portata m/h
ISSWW 600 inf. ISSWW 500 inf. ISSWW 400 inf. ISSWW 300 inf. ISSWW 200 inf. ISSWW 600 sup. ISSWW 300-500 sup. ISSWW 200 sup.
PR1
Power kW
80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 1,0 2,0 3,0 4,0
ISSWW 600 inf. 600 bot. ISSWW 500 inf. 500 bot. ISSWW 400 inf. 400 bot. ISSWW 300 inf. 300 bot. ISSWW 200 inf. 200 bot. 600 topISSWW 600 sup. ISSWW 300-500 top 300-500 sup. 200 topISSWW 200 sup.
KW
2,0
3,0
4,0
200 top ISSWW 200 sup. 300-500 top300-500 sup. ISSWW 200 bot. ISSWW 200 inf. 300 bot. ISSWW 300 inf. 400 bot. ISSWW 400 inf. ISSWW 500 inf. 500 bot. ISSWW 600 inf. 600 bot. ISSWW 600 sup. 600 top
kW
mbar
1,0
2,0
3,0
40,
Flow rate m /h
Perdite di carico
700 6 50 600 550 500
27
1 Coil
Series 800-1000
Capacity Average insul. layer thickness Heat exchange surface Power (T 35 k)* D.H.W. production (T 35 k)* Heating time (T 35k)* Primary flow rate Max. operating temp. Max. operating pressure Net weight Hydraulic fittings Exchanger Recirculation fittings fittings
mm
>100 >100
m
3,00 3,50
kW
88 100
l/h
2162 2457
min
24 26
m/h
3,0 3,0
C
95 95
MPa
1,0 1,0
kg
272 299
KW-WW
Rp 1 Rp 1
PV-PR
Rp 1 Rp 1
Z
Rp 1 Rp 1
* Note: Primary temperature 80C / Secondary temperature:10/45C - D.H.W. = production of domestic hot water.
2 Coil
l ISSWW 800
800
Series 800-1000
Capacity Average insul. layer thickness Coil fittings Heat exchange surface Power (T 35 k)* D.H.W. production (T 35 k)* Heating time (T 35k)* Primary flow rate Max. operating temp. Max. operating pressure Net weight Hydraulic fittings Exchanger Recirculation fittings fittings
mm
>100 >100
top/bot.
top 172227 top bot.
m
1,20 3,00 1,50 3,50
kW
40 88 48 100
l/h
983 2162 1179 2457
min
52 24 54 26
m/h
3,0 3,0
C
95 95
MPa
1,0 1,0
kg
292 323
KW-WW
Rp 1 Rp 1
PV-PR
Rp 1 Rp 1
Z
Rp 1 Rp 1
* Note: Primary temperature 80C / Secondary temperature 10/45C / D.H.W. = production of domestic hot water
28
A
WW
PV
Z
H G F
PR
E D
KW
A
WW PV2 PR2 PV1 Z
C M L H G F
PR1
E
A B C D
KW
D
E F
mm
925 925
mm
1865 2245
mm
191 191
mm
371 371
mm
1071 1231
mm
971 1121
mm
1676 2056
mm
925 925
mm
1865 2245
mm
191 191
mm
371 371
mm
1071 1231
mm
971 1121
mm
1251 1431
mm
1461 1831
mm
1676 2056
29
Multiposition
series 80-100-115-150-200-300
Multi-position storage air casing indirect cylinders are a convenient and cheap solution to your domestic hot water requirements. Their strength lies in the exhaustive nature of the range, from 80 to 300 litres, and in the versatility of installation; moreover, thanks to the limited flow resistance, they are ideal for use in natural flow systems. Recommended for domestic and collective use.
Steel tank, glass-lined using the flow-coating method (850 C). 88 mm inspection flange complete with counter flange and sensor sheath. Corrosion-proof magnesium anode. Heat exchanger with air casing, optimised for natural flow systems owing to the reduced flow resistance. CFC and HCFC-free polyurethane (PU) foam insulation layer. Recirculation fitting.
Capacity Capacity Heat exchange surface
External casing made of sheet metal coated with epoxy powder paint. Primary circuit fittings on both sides for maximum installation flexibility. Multi-position installation options: vertical or horizontal, wall-mounted or floor-standing (floor-standing installation only for mod. 300). Electric integration KITS available (except for the 300 litre model).
GMI 80 GMI 100 GMI 115 GMI 150 GMI 200 GMI 300
l
80 100 115 150 200 300 Max. operating pressure
m
0,65 0,90 1,10 1,10 1,50 2,00 Max. operating pressure of air casing Net Weight
kW
14 22 26 26 33 45 Hydraulic fittings Exchanger fittings
l/h
350 540 645 645 815 1115 Recirculation fittings A
min
15 12 11 15 16 17 B C D
m/h
2,0 2,0 2,0 2,0 2,0 2,0 E F G
C
95 95 95 95 95 95 H L
GMI 80 GMI 100 GMI 115 GMI 150 GMI 200 GMI 300
MPa
0,8 0,8 0,8 0,8 0,8 0,8
MPa
0,4 0,4 0,4 0,4 0,4 0,4
kg
42 51 59,5 67 83,5 130
KW-WW
R R R R R R1
PV-PR
Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1
Z
R R R R R R1
mm
470 470 470 570 570
mm
844 1057 1228 1025 1295
mm
223 223 223 214 214
mm
mm
mm
mm
65 65 65 115 115
mm
257 257 257 262 262
mm
320 500 670 500 800
463 295 65 856 295 65 1027 295 65 819 450 115 1086 450 115 see diagram
Note: *primary circuit temperature 80C / secondary circuit temp 10 /45C / primary flow rate indicated in the table -D.H.W. = domestic hot water. Floor-standing installation only for model GMI 300.
Pote
Versions 45 80-100-115-150-200
40 35 30 25 20 15 5 0,5
BMI 80 BMI 100 BMI 115 - 150 BMI 200 BMI 300
50
kW
Version 300 1
1,5
2,5
Port
Power kW
50 45 40 35
Potenza kW
1200 1100 1000 900 800 700 600 500 400 300 200 100 0,5
Portata m/h
Produzio
kW
BMI 300
l/h
30
80 BMI 80 100 BMI 100 115-150 BMI 115 - 150 200 BMI 200 300
1,5
2,5
Flow rate m /h
Flow rate m /h
Port
30
1200 1100 1000
INDIRECT CYLINDER
description PRIORITY KIT formed by: thermostat in exchange, two-contact relay, bipolar switch, wired cap.
070281
Free Standing
071037
11/4 2,0 kW 230 V- single-phase electrical kit formed by: 11/4 sleeve, gasket, armoured heating element and thermostat to be installed on the lateral screwed connection
071038
11/4 3,0 kW 230 V- single-phase electrical kit composto da: manicotto 1 , guarnizione, resistenza blindata in rame e termostato per installazione su predisposizione attacco filettato laterale
Free Standing
071078
11/4 2,0 kW 230 V- single-phase electrical kit formed by: 11/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection 11/4 3,0 kW 230 V- single-phase electrical kit formed by: 11/4 sleeve, gasket, AISI 321 stainless steel armoured heating element and thermostat to be installed on the lateral screwed connection 2.0 kW 230 V~ 1 SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1 sleeve, gasket, copper armoured heating element and thermostat.
071079
Free Standing
070265
070266
3.0 kW 230 V~ 1 SINGLE-PHASE ELECTRICAL KIT formed by: counter-flange with 1 sleeve, gasket, copper armoured heating element and thermostat.
Free Standing
070267
3.0 kW 400/3 V~ 2 THREE-PHASE ELECTRICAL KIT cormed by: counter-flange with 2 sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors. N.B. not suitable for 800 L and 1000 L model 4.0 kW 400/3 V~ 2 THREE-PHASE ELECTRICAL KIT formed by: counter-flange with 2 sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors. N.B. not suitable for 800 L and 1000 L model 5.0 kW 400/3 V~ 2 THREE-PHASE ELECTRICAL KIT formed by: counter-flange with 2 sleeve, gasket, copper armoured heating element, thermostat equipped with brackets and connectors. N.B. not suitable for 800 L and 1000 L model
070268
070269
31
INDIRECT CYLINDER
description SPIROID EXCHANGER KIT 1.0 sqm formed by: counter-flange, finned coil made of tinned copper 1 sqm; gasket, union set, round grill, fastening screws and nuts. FOR ALL SERIES SPIROID EXCHANGER KIT 1.8 sqm ONLY FOR SERIES 400-500-600-800-1000 formed by: counter-flange, finned coil made of tinned copper 1.8 sqm; gasket, union set, round grill, fastening screws and nuts.. 3.06.0 kW 400/3V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 160-200-300 4.08.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000 5.08.0 kW 400/3 V~ THREE-PHASE INOX ELECTRICAL KIT formed by: counter-flange, gasket, three-element Incoloy 800 stainless steel heating element, thermostat and support bracket. RECOMMENDED FOR SERIES 400-500-600-800-1000 1.2 kW 230 V~ ELECTRICAL KIT - FOR SERIES 80-100 formed by: copper armoured heating element, thermostat and wired cap. Only for wall-mount vertical or horizontal installations.
030528
030525
Free Standing
070137
070138
070136
Multiposition
070133
070134
1.5 kW 230 V~ ELECTRICAL KIT - FOR SERIES 115 formed by: copper armoured heating element, thermostat and wired cap. Only for wall-mount vertical or horizontal installations 2.0 kW 230 V~ ELECTRICAL KIT - FOR SERIES 150-200
070127
090629
32
Inertial puffers
The range of inertial puffers is formed by heating water storages with the opportunity to combine a fixed coil exchanger, too. They allow storing heating water generated by discontinuous heating systems; therefore, they allow a considerable recovery and/or exploitation of thermal energy that would be unused or even wasted. From this point of view, they well integrate into energy saving systems, and become the thermal source of the energy system within heating and domestic hot water generation systems. Owing to their peculiarity, they are usually connected to systems that generate heat in a discontinuous way, such as for example wood-fired boilers, solid-fuel stacks or stoves, or rather installed in low water systems to limit the interventions of the burners. As for the version with fixed exchanger, besides what is said above, it is used for maximum exploitation of thermal solar systems or with heat pump. The capacity field covered by this range is included between 200 and 1,000 litres. Product lines cover the standard, with front hatchway, solar with fixed exchanger and front hatchway up to solar with the production of domestic hot water. All products are equipped with fittings for electric integrations by means of specific kits from 3.0 kW to 12.0 kW, while the products having the hatchway can install further electric kits from 2.0 to 10.0 kW, or kits with tinned copper spiroid exchangers.
Recycling
800 and 1,000l puffers have been designed so that they can be completely disassembled at the end of their life cycle, in a way to allow their correct recycling and/or the disposal of their components.
We undertakes streamlining the industrial activities and the respect of the environment. In order to reduce the impact over the environment to the minimum, we removed the hydrofluorocarbons (CFC-HCFC) from the insulation layer, and always pays great attention to the recyclability of the components.
33
Intertial Puffer
puffer
PH
Inertial puffers are characterised by the ability to store heating water that comes from several sources, mainly discontinuous ones. In addition, they are arranged for the installation of an electric integration, which is supplied by means of specific kits up to 12 kW.
Raw carbon steel internal tank. Hydraulic fittings to be found on the rear. Probe sheaths (Tr) to be found on the rear. CFC and HCFC-free very thick rigid expanded polyurethane (PU) insulation layer. Easy entry system plus (EPS) for series 800/1000. External coloured plastic (PVC) coating. Adjustable feet for floor standing. Arrangement of electric heating element with front 1 sleeve. Available electrical KIT with Incoloy 825 stainless steel heating elements on a 1 fitting with powers from 3 to 12 kW and three-phase connection.
PH no hatchway
Capacity Insulation layer thickness
Series 200-300-400-500-600-700-800-1000
Max. working temperature Max. working pressure Net weight Heating element fitting Hydraulic fittings Fitting on upper bottom Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Number of probes/ diameter Nr/mm
ISPHO 200 ISPHO 300 ISPHO 400 ISPHO 500 ISPHO 600 ISPHO 800 ISPHO 1000
l
200 300 400 500 600 800 1000
mm
>50 PU >50 PU >50 PU >50 PU >50 PU >50 >50
C
95 95 95 95 95 95 95
MPa
0,3 0,3 0,3 0,3 0,3 0,3 0,3
kg
51 75 97 113 174 140 164
R
Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1
Nr/mm
3/16 3/16 3/16 3/16 3/16 3/Rp1/2 3/Rp1/2
PH with hatchway
Capacity Capacity Insulation layer thickness
Series 200-300-400-500-600-700-800-1000
Max. working temperature Max. working pressure Net weight Heating element fitting Hydraulic fittings Fitting on upper bottom Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Number of probes/ diameter Nr/mm
ISPH 200 ISPH 300 ISPH 400 ISPH 500 ISPH 600 ISPH 800 ISPH 1000
l
200 300 400 500 600 800 1000
mm
>50 PU >50 PU >50 PU >50 PU >50 PU >50 >50
C
95 95 95 95 95 95 95
MPa
0,3 0,3 0,3 0,3 0,3 0,3 0,3
kg
53 77 99 115 176 143 167
R
Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1
Nr/mm
3/16 3/16 3/16 3/16 3/16 3/Rp1/2 3/Rp1/2
m
750 950 Maximum working pressure 3,00 3,50 Net weight
kW
88 100 Exchanger fittings
l/h
2162 2457
min
24 26 Heating element fitting
m/h
3,0 3,0 Hydraulic fittings
mm
>50 >50 Fitting on upper bottom Rp 2 Rp 2
C
95 95 Number of probes/ diameter
MPa
0,3 0,3
kg
205 241
PV-PR
Rp 1 Rp 1
R
Rp 1 Rp 1
Nr/mm
3/Rp1/2 3/Rp1/2
3 to 9 kW 1 1/2 Incoloy 825 stainless steel three-phase heating element electrical kit
3 kW 400/3 V - 11/2 electrical kit 6 kW 400/3 V - 11/2 electrical kit 9 kW 400/3 V - 11/2 electrical kit
34
puffer
A
A
MI 1
Tr
MI 1 MC MI 2 RI1 R i c. I
MC MI 2
Tr
Tr RC
FG
RI 1 Ric. I
RC
E
RI 2 / SC
R I 2/ S C
NO hatchway A C D E F G H L M N
ISPHO 200 ISPHO 300 ISPHO 400 ISPHO 500 ISPHO 600 ISPHO 800 ISPHO 1000
mm
610 650 755 755 810 880 880
mm
1329 1560 1553 1818 1749 1865 2245
mm
150 156 161 161 123 191 191
mm
261 336 321 364 330 371 371
mm
621 751 721 914 930 971 1121
mm
761 841 878 1056 1075 1071 1231
D 0
mm
841 984 976 1131 1150 1251 1431
mm
1041 1236 1176 1381 1400 1461 1831
mm
1195 1416 1385 1651 1658 1676 2056
mm
735 785 839 906 891 1123 1268
A
OA B
B
M
MI 1 MC
Tr
Ml 1 MC
L H
Ml 2 Rl1 Ric.1
MI 2 RI 1 Ric. I
G F
Tr RC
FG
Tr
D E
RC
RI 2 / SC
E D
RI 2 / SC
ISPH 200 ISPH 300 ISPH 400 ISPH 500 ISPH 600 ISPH 800 ISPH 1000
mm
610 650 755 755 810 880 880
mm
627 674 775 775 827 910 910
mm
1329 1560 1553 1818 1749 1865 2245
mm
150 156 161 161 123 191 191
mm
261 336 321 364 330 371 371
mm
621 751 721 914 930 971 1121
mm
761 841 878 1056 1075 1071 1231
mm
841 984 976 1131 1150 1251 1431
mm
1041 1236 1176 1381 1400 1461 1831
mm
1195 1416 1385 1651 1658 1676 2056
mm
735 785 839 906 891 1123 1268
A
MI 1
SCA 1
SCAU
RI 2 / SC
mm
880 880
mm
910 910
mm
1865 2245
mm
191 191
mm
371 371
mm
971 1121
RC
F GH
MI 2 RI 1 Ric. I
MC
mm
1071 1231
mm
1251 1431
mm
1461 1831
mm
1676 2056
mm
371 371
mm
971 1121
35
Tank in Tank
solar PUFFER
TTS
series 600-750-900
The Tank in Tank range of solar puffers with the production of domestic hot water is an integrated system formed by a thermal storage for heating (puffer) and a glass-lined tank, which is dipped inside the puffer, for the production of domestic hot water. The insulation layer is manufactured by means of a new system that combines the technology of the injected polyurethane (PU) with the flexibility of NEOPOR (EPS) (only for series 750-900). This solution allows the installer to have a plug and play product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a trouble-free disassembly and re-assembly of the insulation layer for an easier installation in boiler rooms. Owing to their peculiarity, they are usually connected to systems that generate heat in a discontinuous way, such as for example wood-fired boilers, solidfuel stacks or stoves, or rather installed in low water systems to limit the interventions of the burners. The fixed exchanger to be found in the system is used for maximum exploitation of thermal solar systems or with heat pump.
Raw carbon steel internal tank (puffer). Carbon steel fixed exchanger welded to the puffer. Perforated diaphragm fastened to the puffer for improved internal lamination. Domestic hot water steel tank, glass-lined using the flow-coating method (850C). Corrosion-proof magnesium anode (domestic hot water tank). Hydraulic fittings to be found on the rear. Probe sheaths (Tr) to be found on the rear. CFC and HCFC-free very thick expanded polyurethane insulation layer. Easy entry system for series 750 and 900. External coloured plastic (PVC) coating. Adjustable feet for floor standing.
Heating capacity
D.H.W. capacity
Exchange surface
Power (t 35)*
l
130 180 230 Net weight
m
2,10 2,50 3,00 Exchanger fittings
kW
81 91 105 Vent fitting
mm
50 50 50 DHW fittings
C
95 95 95 Heating fitting
MPa
0,3 0,3 0,3 Number of probes/ diameter
kg
190 220 260
PV-PR
Rp 1 Rp 1 Rp 1
SF
Rp Rp Rp
WW, Z, KW
Rp Rp Rp
HZ VL, HZ RL
Rp 1 Rp 1 Rp 1
Nr/mm
4/ Rp 4/ Rp 4/ Rp
36
solar PUFFER
A
att att att
Tr Tr Tr
att att
att att
PV
H G
att
Tr C/S
att
E D
PR
SF
WW
KW Z
N
F
mm
780 800 800
mm
1831 1932 2305
mm
130 196 196
mm
270 351 376
mm
395 445 481
mm
870 951 1026
mm
1603 1623 1996
mm
200 200 200
mm
180 180 180
mm
245 245 245
37
The range of gas water heaters is the result of detailed research and in-depth experiments related to the efficiency, safety, aesthetic appearance and energy savings in strict compliance with the applicable norms in force. The range of capacities covered by this product line is from 50 to 2000 litres with power ratings of between 4 kW and over 34 kW of heat output. The range meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include natural draught appliances, which are ideal for the rapid and cheap production both small and large quantities of water, as well as the sophisticated fan flue appliances which also solve installation difficulties when traditional systems cannot be fitted.
Magnesium anode
Featured in all the models in the range, this anode makes for effective electrochemical tank protection.
Environmentally friendly
Multi-gas burner
All the gas powered appliance models are fitted with multi-gas burners for operation with methane gas or LPG.
We strive to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recyclable components.
Maximum safety
Triple safety gas valve with operating thermostat, flame detection thermocouple (ionisation for electronic versions) and maximum temperature thermostat and flue gas sensor (for natural draught versions) to avoid possible malfunctions.
39
Natural draught
series 50-80-100-120
Wall-hung storage open-vented and Natural draught gas water heaters are the simplest and cheapest solution for the rapid production of domestic hot water.
Steel tank, glass-lined using the flow-coating method (850C). Corrosion-proof magnesium anode. CFC and HCFC-free polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. Piezoelectric ignition. Burner with 3 distributing pipes. Triple safety gas valve: operating thermostat, flame detection thermocouple and maximum temperature control. Flue gas sensor (DCF). Stored water temperature indicator. Designed to operate on methane gas or LPG (nozzles included). Operation without electrical connections.
flow Max. qty. Useful Heat. time Cont. rate of flue Power t=50C t=30C gases
Max. Max. Methane LPG operating consumption consumption operating temp. press.
Net Weight
Hydraulic fittings
Gas fitting
kW
4,5 6,2 6,2 6,5
kW
3,8 5,3 5,3 5,6
min
43 55 65 77
l/min
1,8 2,5 2,5 2,7
g/s
1,96 2,75 3,22 3,31
C
308 292 284 275
m/h
0,50 0,65 0,65 0,70
g/h
300 395 395 425
C
75 75 75 75
MPa
0,8 0,8 0,8 0,8
kg
20 28 32 36
KW-WW
R R R R
G
G 3/8 G 3/8 G 3/8 G 3/8
F (mm)
81 81 81 81
mm
mm
100
40
450
Fan flue
series 80-120
Wall-hung storage room-sealed and Fan flue gas water heaters are a sophisticated yet brilliant way to solve the most challenging installation difficulties where traditional appliances cannot be used, for the rapid production of domestic hot water.
Steel tank, glass-lined using the flow-coating method (850C). Corrosion-proof magnesium anode. CFC and HCFC-free polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. Electronic ignition with flame detection and ionisation flame control. Flue gas extraction fan with safety pressure switch. Triple safety gas valve: operating thermostat, ionisation flame detection and maximum temperature control. Stored water temperature indicator. Designed to operate on methane gas or LPG (nozzles included). Coaxial or split flue gas discharge available.
Accessories on page 46
Cont. f Max. qty. Useful Heat. time low rate of flue Power t=50C t=30C gases
Max. Max. Methane LPG Net Hydraulic Gas operating weight consumption consumption operating fittings fitting temp. press.
l TF 80
78
kW
4,0 4,0
kW
3,4 3,4
min
84 127
l/min
1,6 1,6
g/s
2,20 2,20
C
91 91
m/h
0,42 0,42
g/h
246 246
C
75 75
MPa
0,8 0,8
kg
40 48
KW-WW
R R
G
R 3/8 R 3/8
F (mm)
28 28
mm
1069
mm
mm mm
TF 120 118
Note: room-sealed, fan flue C12 C32 C42 C82 / category II 2H3+ / Max absorbed power: 44W -230V~
A 286
212
41
Natural draught
series 115-150-200
Floor-standing storage open-vented and Natural draught gas water heaters are the best solution for the production of large quantities of domestic hot water. They are also ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.
Steel tank, glass-lined using the flow-coating method (850C). Corrosion-proof magnesium anode. CFC and HCFC-free polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. Piezoelectric ignition. Stored water temperature indicator. Triple safety gas valve: operating thermostat, flame detection thermocouple and maximum temperature control. Flue gas sensor (DCF). Designed to operate on methane gas or LPG (nozzles included). Operation without electrical connections.
Cont. Max. qty. Heat Useful Heat. Capacity output time flow rate of flue power t=50C t=30C gases
Methane consumption
LPG Max. Max. Flue Net Hydraulic Recirculation Gas consum- operating operating weight and gas fittings fitting ption temp. press. discharge discharge
kW
6,9 7,2 8,0
kW
5,7 6,0 6,6
min
72 92 111
l/min
2,7 2,8 3,2
g/s
3,36 3,80 3,76
C
284 242 234
m/h
0,75 0,76 0,84
g/h
445 445 495
C
75 75 75
MPa
0,8 0,8 0,8
kg
41 50 71
KW-WW
R R R
Z-E
Rp Rp Rp
G
R R R
F (mm)
81 81 81
mm mm
mm
115/150 470 F
WW KW WW
200 570 F
KW
230 Z B A 65
42
259
Natural draught
series 300-500
Floor-standing storage open-vented and Natural draught gas water heaters are designed to store large quantities of hot water with a view to ensuring greater value for money. The version featuring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.
Steel tank, glass-lined using the flow-coating method (850C). 134 mm front inspection hatch. Corrosion-proof magnesium anode. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. Flue gas sensor (DCF). Piezoelectric ignition (electronic for the EG/PRE version). Triple safety gas valve: operating thermostat, flame detection thermocouple (ionisation for the EG/PRE version) and maximum temperature control. Stored water temperature indicator. Designed to operate on methane gas or LPG (nozzles included).
Cont. Max. Heat Useful Heat. flow qty. Capacity output time Power t=50C rate of flue t=30C gases
Methane consumption
LPG Max. Max. Flue Net Hydraulic Recirculation Gas consum- operating operating weight and gas fittings fitting ption temp. press. discharge discharge
kW
19,5 19,5 24,0 24,0
kW
17,2 17,2 21,0 21,0
min
62 62 82 82
l/min
8,2 8,2 10,0 10,0
g/s
9,59 9,59 11,58 11,58
C
230 230 214 214
m/h
2,10 2,10 2,52 2,52
g/h
1250 1250 1500 1500
C
75 75 75 75
MPa
0,8 0,8 0,8 0,8
kg
133 133 178 178
KW-WW
Rp 1 Rp 1 Rp 1 Rp 1
Z-E
Rp Rp Rp Rp
G
R R R R
F (mm)
122 122 122 122
mm
mm
mm
1611 821 1084 1611 821 1084 2144 1285 1643 2144 1285 1643
Note: for the EG/PRE electronic version, the appliance needs to be connected to the 230 V~ electricity mains / open-vented, natural draught B11BS / category II 2H3+
300/500
720
720
KW
KW
Z A C C 499 499
G
Z E B 499 A
WW
E
G
WW
133
499
43
Natural draught
series 600-800-1000-1500-2000
Floor-standing storage open-vented and Natural draught high capacity gas water heaters provide large quantities of hot water and can be installed in series/parallel where large consumption levels are required. The version featuring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.
Hot galvanised steel tank. Corrosion-proof magnesium anode. Very thick mineral wool insulation layer for reduced heat loss. Stored water temperature indicator. External casing made of pre-painted sheet metal. Piezoelectric ignition. Triple safety gas valve: operating thermostat, flame detection thermocouple and maximum temperature control. Flue gas sensor (DCF). Designed to operate on methane gas or LPG (nozzles included). Operation without electrical connections. Electronic version (EG/PE) available upon request.
Capacity
Heat Output
Useful Power
Cont. Flue qty. flow rate ofMax. gas flue gases t=30C temp.
Methane consumption
LPG consumption
Gas fitting
l EG/P 600 575 EG/PE 600* EG/P 800 800 EG/PE 800* EG/P 1000 950 EG/PE 1000* EG/P 1500 1450 EG/PE 1500* EG/P 2000 1850 EG/PE 2000*
kW
26,7 34,8 34,8 34,8 34,8
kW
22,9 29,9 30,2 29,6 30,2
min
92 98 115 180 225
l/min
10,9 14,3 14,3 14,1 14,3
g/s
23,2 31,1 31,1 31,1 31,1
C
136 135 135 135 135
m/h
2,70 3,60 3,60 3,60 3,60
g/h
1988 2581 2581 2581 2581
C
75 75 75 75 75
MPa
0,6 0,6 0,6 0,6 0,6
kg
194 241 276 377 452
KW-WW
Rp 1 Rp 1 Rp 1 Rp 1 Rp 1
Z-E
Rp 1 Rp 1 Rp 1 Rp 1 Rp 1
G
R R R R R
F (mm)
140 160 160 160 160
Note: open-vented, natural draught B11BS / category II 2H3+ *Version with electronic ignition
A
WW
mm EG/P 600 EG/P 800 EG/P 1000 EG/P 1500 EG/P 2000
780 980 1080 1180 1280
mm
2165 1975 2025 2255 2475
mm
2000 1810 1860 2090 2310
mm
1730 1470 1470 2000 2150
mm
1010 900 900 960 960
mm
310 340 340 340 340
Z
KW
44
D C
Fan flue
series 220-300-400
Floor-standing storage room-sealed and fan flue gas water heaters feature the most advanced technological solutions to solve the most challenging installation problems. Their electronic controls makes them ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings.
Steel tank, glass-lined using the flow-coating method (850C). Corrosion-proof magnesium anode with anode control device. Very thick mineral wool insulation layer. External casing made of pre-painted sheet metal. Electronic ignition with flame detection and ionisation flame control. Flue gas extraction fan with safety pressure switch. Triple safety gas valve: operating thermostat, ionisation flame detection and maximum temperature control. Timer clock. Stored water temperature indicator. Designed to operate on methane gas or LPG (nozzles included). Coaxial or split flue gas discharge available.
Accessories on page 46
Capacity
Heat output
Useful Power
Methane consumption
LPG consumption
Max. Max. Net Hydraulic Recirculation operating operating weight and fittings discharge temp. press.
Gas f itting
kW
26,7 30,6 30,6
kW
24,1 27,1 27,1
min
33 29 29
l/min
11,5 14,6 14,6
g/s
16,8 16,7 17,3
C
172 162 157
m/h
2,82 3,25 3,25
g/h
2100 2400 2400
C
75 75 75
MPa
0,6 0,6 0,6
kg
141 170 210
KW-WW
Rp 1 Rp 1 Rp 1
Z-E
Rp 1 Rp 1 Rp 1
G
R R R
F (mm)
100 100 100
Note: room-sealed, fan flue C12 C32 C42 C82 / category II 2H3+ / max absorbed power: 62W -230V~
mm
1750 1975 2150
mm
390 390 390
mm
590 590 590
mm
790 790 790
mm
1150 1375 1540
A F
WW
Z
KW
E C D E
45
030341
COAXIAL OUTLET KIT 60/28 mm - 1 meter coaxial mouth - 1m 0 60/28 mm coaxial pipe discharge/suction end - wall cover roses 60/28 mm coaxial extension cord 0.5 meters 60/28 mm coaxial extension cord 1.0 meter 90 60/28 mm coaxial elbow 32/28 mm SPLIT OUTLET KIT - 1 meter n. 1 1 meter 28 mm outlet extension cord n. 1 1 meter 32 mm outlet extension cord discharge/suction end - wall cover roses 28 mm outlet extension cord 0,5 meters 28 mm outlet extension cord 1.0 meter 32 mm suction extension cord 0.5 meters 32 mm suction extension cord 1.0 meter 90 28 mm outlet elbow 45 28 mm outlet elbow 90 32 mm suction elbow
140406 COAXIAL OUTLET KIT 60/100 mm -1 meter multi-directional 90 coaxial elbow with inspections, coaxial pipe and discharge/suction 140414 Vertical 60/100 mm flanged coaxial stub pipe 140407 60/100 mm coaxial extension cord - 1.0 meter 140410 90 60/100mm coaxial elbow 140423 COAXIAL OUTLET KIT ON ROOF 80/110 mm - 1 meter coaxial pipe, flanged concentric 118-100 reduction, gasket, 80-60 reduction; device for roof outlet equipped with sleeve and fastening screws
140408 80/-80mm SPLIT OUTLET KIT - 1 meter formed by: splitter with condensation outlet and inspections, n.2 90 elbows, n.2 extension cords, suction/discharge 140409 v 80 mm extension cord - 1 meter 140411 90 80 mm elbow
46
The Styleboiler range of electric storage water heaters offers an extensive array of models for the production of domestic hot water (D.H.W.) with a capacity ranging from 10 to 1000 litres and power ratings from 1.2 to 10 kW with single- and three-phase connections. The range meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include rapid models, which are ideal for the rapid and cheap production of small quantities of water, smart models which are small water heaters designed for installations where limited space is available, the classic standard models devised to accommodate the essential basic requirements of the market, and also the interline product line, providing a large number of combinations to meet the highest expectations as regards quality in observance of European and international standards.
External control knob used to facilitate the water heater temperature adjustment, combined with the flange for easy inspection and cleaning.
Environmentally friendly
Dual Safety
Thanks to the flow-coating enamelling process at 850C for guaranteed quality internal protection or via classic Teflon-coating.
Thanks to the presence of both an operating thermostat and a maximum temperature thermostat to avoid possible malfunctions.
We strives to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbons (CFC-HCFC) in the insulation (PU) layer and makes continuous efforts to use recyclable components.
Magnesium anode
IP Degree of Protection
Featured in all the models in the range, this anode makes for effective electrochemical tank protection.
Styleboiler water heaters are safe because they are splash-proof and are specially designed for installation close to the water delivery points, even in public and collective settings.
47
series 10-15-30
oversink version 10-15-30
A A B B
KW
Rapid
undersink version 10-15
E
KW
E
WW WW
G F
KW
KW
WW
WW
G F
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
kW
1,2 1,2 1,2 1,2 1,2
V~
230 230 230 230 230
min
30 30 46 46 92
C
75 75 75 75 75
Mpa
0,8 0,8 0,8 0,8 0,8
Kg
6,0 6,0 7,5 7,5 10
KW-WW
R R R R R
mm
261 261 296 296 366
mm
251 251 285 285 355
mm
450 450 498 498 568
mm
228 250 248 270 384
mm
100 100 100 100 100
mm
62 62 69 69 89
mm
189 189 216 216 266
series 10-15-30
Wall-hung electric storage water heaters are ideal for the rapid and cheap production of small quantities of water. They can be installed above or below the sink (30 Litres above only). The external control knob (SE) makes for easier adjustment of the water temperature.
oversink version 10-15-30
A A B B
KW
Rapid SE
E
WW
Steel tank, glass-lined using the flow-coating method (850C). Tank inspection flange. Corrosion-proof magnesium anode. Armoured copper heating element fitted on a flange. Regulation and safety rod thermostat with external control knob. Polystyrene insulating shells (EPS) for reduced heat loss. Shock-resistant polypropylene (PP) casing and back. F Brackets for wall mounting available upon request. LED indicator light. IPX5 protective cover over electrical parts.
KW
WW KW
WW
D B
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
l Pony 10/SE Pony 10/SE s Pony 15/SE Pony 15/SE s Pony 30/SE
10 10 15 15 30
kW
1,2 1,2 1,2 1,2 1,2
V~
230 230 230 230 230
min
30 30 46 46 92
C
75 75 75 75 75
Mpa
0,8 0,8 0,8 0,8 0,8
Kg
6,0 6,0 7,5 7,5 10,0
KW-WW
R R R R R
mm
261 261 296 296 366
mm
251 251 285 285 355
mm
450 450 498 498 568
mm
228 250 248 270 384
mm
100 100 100 100 100
mm
62 62 69 69 89
mm
189 189 216 216 266
48
wall-hung, storage
series 30
450 120 277
Smart
Wall-hung electric storage water heaters are ideal for the rapid and cheap production of small quantities of water where the installation space is limited.
KW
WW
120
106,5
Capacity
Power
Voltage
Net weight
Hydraulic fittings
l VDO 30
25
kW
1,2
V~
230
min
77
C
75
MPa
0,8
kg
12
KW-WW
R
Steel tank treated with thermo-hardening resins (Teflon) or glass-lined using the flow-coating method (850C) depending on the model and/or version. Corrosion-proof magnesium anode. Armoured copper heating element fitted on a 1 14 coupling. Regulation and safety rod thermostat. CFC and HCFC-free polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. LED indicator light. IPX3 protective cover over electrical parts (IPX2 for VB 30). Stored water temperature indicator.
489
Heat. time t=50C
260
Max. operating temp.
Capacity
Power
Voltage
Net weight
Hydraulic fittings
l VFO 30
25
kW
1,2
V~
230
min
77
C
75
MPa
0,8
kg
12
KW-WW
R
Standard mini
358
series 30
Wall-hung electric storage water heaters are ideal for the rapid and cheap production of small quantities of water where the installation space is limited.
368
381
270
WW
KW
100
Capacity
Power
Voltage
Net weight
Hydraulic fittings
l VD 30
30
kW
1,2
V~
230
min
92
C
75
MPa
0,8
kg
12
KW-WW
R
Steel tank treated with thermo-hardening resins (Teflon) or glass-lined using the flow-coating method (850C) depending on the model and/or version. Corrosion-proof magnesium anode. Armoured copper heating element fitted on a 1 14 coupling. Regulation and safety rod thermostat. CFC and HCFC-free polyurethane (PU) foam insulation layer. External casing made of sheet metal coated with epoxy powder paint. LED indicator light. IPX3 protective cover over electrical parts (IPX2 for VB 30). Stored water temperature indicator.
554
Capacity
Power
Voltage
Net weight
Hydraulic fittings
l VF 30
30
kW
1,2
V~
230
min
92
C
75
MPa
0,8
kg
12
KW-WW
R
115
49
wall-hung, storage
Standard
series 50-80-100
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are available in a vertical version, vertical universal left-right thermo version, horizontal version and horizontal thermo version.
Steel tank treated with thermo-hardening resins (Teflon) or glass-lined using the flow-coating method (850C) depending on the model and/or version. Armoured copper heating element fitted on a 1 14 coupling. Corrosion-proof magnesium anode. Regulation and safety rod thermostat; LED indicator light.
External casing made of sheet metal coated with epoxy powder paint. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts (IPX2 for versions V/T 50-80-100). Stored water temperature indicator.
Capacity
Power
Voltage
Net weight
Hydraulic fittings
l VD 50 VD 80 VD 100
50 80 100
kW
1,2 1,2 1,2
V~
230 230 230
min
153 245 306
C
75 75 75
MPa
0,8 0,8 0,8
kg
15,1 21,8 25,5
KW-WW
R R R
mm
550 780 930
mm
320 550 700
450
475
270 B
KW WW
100
112
50
Standard SE
450
series 50-80-100
450
475
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The external control knob (SE) makes for easier adjustment of the water temperature. Also recommended for industrial and collective use. Also available in the thermo version.
Steel tank, glass-lined using the flow-coating method (850C). 88 mm tank inspection flange. Corrosion-proof magnesium anode. Armoured copper heating element fitted on a flange. Regulation and safety rod thermostat with external control knob. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts. External casing made of sheet metal coated 112 with epoxy powder paint. LED indicator light. Stored water temperature indicator.
475
270
270
B
KW
100
KW WW
WW
100
112
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
l VF 50 SE VF 80 SE VF 100 SE
50 80 100
kW
1,2 1,2 1,2
V~
230 230 230
min
153 245 306
C
75 75 75
MPa
0,8 0,8 0,8
kg
15,5 20,5 25,5
KW-WW
R R R
mm
509 729 879
mm
281 498 648 Note: * = 3.0 kW 230 and 400/3 V~ heating element available, in which case the external control knob SE is no longer required.
Standard top
450 450 475 475
series 40-50-80-100
Wall-hung electric storage water heaters are designed to meet the highest expectations as regards quality in observance of European and international standards. The insulation layer is made of very thick high-density polyurethane (PU) foam to minimise heat loss.
Steel tank, glass-lined using the flow-coating method (850C). 134 tank inspection flange. Corrosion-proof magnesium anode. Armoured copper heating element fitted on a flange. External regulation and safety capillary thermostat. External casing made of sheet metal coated with epoxy powder paint. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. LED indicator light. 112 IPX5 protective cover over electrical parts complete with cable and plug. Stored water temperature indicator.
Max. oper. press. Net weight Hydraulic fittings A B
270
270 B B
KW
KW
WW
WW
100
100
112
Capacity
Power
Voltage
Insul. thickness
kW
1,2 1,2 1,2 1,2
V~
230 230 230 230
min
122 153 245 306
mm
25 25 25 25
kWh/24h
0,78 0,87 1,13 1,30
C
75 75 75 75
MPa
0,8 0,8 0,8 0,8
kg
18,5 21,0 27,0 33,0
KW-WW
R R R R
mm
513 596 799 1013
mm
292 375 587 801
51
wall-hung, storage
Standard SE
series 120-150-200
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The external control knob (SE) makes for easier adjustment of the water temperature. Also recommended for industrial and collective use. Also available in the thermo version.
Steel tank, glass-lined using the flow-coating method (850C). 88 mm tank inspection flange. Corrosion-proof magnesium anode. Armoured copper heating element fitted on a flange. Regulation and safety rod thermostat with external control knob. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts. External casing made of sheet metal coated with epoxy powder paint. LED indicator light. Stored water temperature indicator.
Accessories on page 60
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
kW
1,5 2,0* 2,0*
V~
230 230* 230*
min
294 275 367
C
75 75 75
MPa
0,8 0,8 0,8
kg
29,0 42,0 51,5
KW-WW
R R R
mm
1029 945 1205
mm
605 500 800
Note: * = 3.0 kW 230 and 400/3 V~ heating element available, in which case the external control knob SE is no longer required.
270 A B
431 B A 156
KW
100
WW
193
112
KW
230
WW
52
244
wall-hung, storage
Standard termo
series 50-80-100
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are available in a vertical version, vertical universal left-right thermo version, horizontal version and horizontal thermo version.
Steel tank treated with thermo-hardening resins (Teflon) or glass-lined using the flow-coating method (850C) depending on the model and/ or version. Armoured copper heating element fitted on a 1 14 coupling. Corrosion-proof magnesium anode. Regulation and safety rod thermostat. LED indicator light. External casing made of sheet metal coated with epoxy powder paint. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts (IPX2 for versions V/T 50-80-100). Stored water temperature indicator.
Capacity
Power
Voltage
Net weight
Hydraulic fittings
Coil fittings
kW
1,2 1,2 1,2
V~
230 230 230
min
153 245 306
C
75 75 75
MPa
0,8 0,8 0,8
kg
17,0 23,5 27,5
KW-WW
R R R
PV-PR
Rp Rp Rp
mm
548 779 930
mm
319 550 701
mm
229 229 229
mm
132 363 363
450 PV 476
270 D PR PR B A
PV
124
WW
100
KW
53
wall-hung, storage
Standard termo SE
serieS 120-150-200
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The external control knob (SE) makes for easier adjustment of the water temperature. Also recommended for industrial and collective use. Also available in the thermo version.
Steel tank, glass-lined using the flow-coating method (850C). 88 mm tank inspection flange. Corrosion-proof magnesium anode. Armoured copper heating elemen t fitted on a flange. Regulation and safety rod thermostat with external control knob. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts. External casing made of sheet metal coated with epoxy powder paint. LED indicator light. Stored water temperature indicator
Accessories on page 60
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
Coil fittings
l VF/T 120/SE DX VF/T 120/SE SX VF/T 150/SE DX VF/T 150/SE SX VF/T 200/SE DX VF/T 200/SE SX
120 150 200
kW
1,5 2,0* 2,0*
V~
230 230* 230*
min
294 275 367
C
75 75 75
MPa
0,8 0,8 0,8
kg
37,0 56,5 66,0
KW-WW
R R R
PV-PR
Rp Rp Rp
m
0,6 0,9 0,9
kW
19,0 33,0 33,0
I/h
469 810 810
m/h
2,0 2,0 2,0
mm
mm
1205 800
Note: * = 3.0 kW 230 and 400/3 V~ heating element available, without control knob **= primary circuit temperature 80C / secondary circuit temp 10 /45C / primary flow rate indicated in the table -D.H.W. = domestic hot water.
PV
PR 244
PR
231
KW
100
WW
112
KW
230
WW
156
54
wall-hung storage
new
series 80-100-120-150-200
Electric water heaters with heat exchanger suitable for solar application, are the basic product range devised to cater the most varied market requirements. Suitable for collective use.
Armored copper heating element fitted on a 88 mm flange with solar sensor sheath included. Steel tank, glass-lined using the flow coating method (850 C). Corrosion-proof magnesium anode Regulation and safety rod thermostat Indicator light. External casing made of steel sheet metal coated with epoxy powder paint. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts. Stored water temperature indicator Available with left or right hydraulic connections. Increased size coil.
Capacity
Power
Voltage
Heating time (T 50 C)
Net weight
Hydraulic connections
Coil connections
l VDT/S 80 DX VDT/S 80 SX VDT/S 100 DX VDT/S 100 SX VDT/S 120 DX VDT/S 120 SX VDT/S 150 DX VDT/S 150 SX VDT/S 200 DX VDT/S 200 SX
80 100 120 150 200 A
kW
1,5 1,5 1,5 2,0 2,0 B
V~
230 230 230 230 230 C
min
23 00 29 00 34 00 30 00 40 00 D E
C
95 95 95 95 95 F
MPa
0,8 0,8 0,8 0,8 0,8 G
kg
28,5 33,5 37,0 56,0 65,5 H L
KW-WW
Rp Rp Rp R R M
PV-PR
R R R R R R
m
0,6 0,6 0,6 0,9 0,9 S
mm
305 455 605 500 800
mm
231 231 231 241 241
mm
475 475 475 555 555
mm
450 450 450 540 540
mm
270 270 270 431 431
mm
380 380 380 486 486
mm
100 100 100 230 230
mm
112 112 112 156 156
mm
128 128 128 118 118
mm
250 250 250 450 450
mm
731 878,5 1028,5 945 1205
D F S B PV E G S R
F
B
PV
PR M A C L A PR C M L
KW
WW
KW
WW
Versions 60-120
Versions 150-200
55
Standard horizontal
series 50-80-100-200
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are available in a vertical version, vertical universal left-right thermo version, horizontal version and horizontal thermo version.
Steel tank treated with thermo-hardening resins (Teflon) or glass-lined using the flow-coating method (850C) depending on the model and/ or version. Armoured copper heating element fitted on a 1 14 coupling. Corrosion-proof magnesium anode. Regulation and safety rod thermostat.
Capacity Power
LED indicator light. External casing made of sheet metal coated with epoxy powder paint. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts (IPX2 for versions V/T 50-80-100). Stored water temperature indicator.
Voltage
Net Weight
Hydraulic fittings
l OD 80 DX OD 80 SX OD 100 DX OD 100 SX
80 100
kW
1,2 1,2
V~
230 230
min
245 306
C
75 75
MPa
0,8 0,8
kg
20,5 25,5
KW-WW
R R
mm
mm
mm
mm
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
kW
1,2 1,2 1,2 1,2 2,0 2,0
V~
230 230 230 230 230 230
min
153 245 306 367 275 367
C
75 75 75 75 75 75
MPa
0,8 0,8 0,8 0,8 0,8 0,8
kg
15,5 20,5 25,5 29,0 65,5 71,5
KW-WW
R R R R R R
mm
545 776 926 1058 1024 1294
mm
mm
mm
120 189 236 272 351 305 422 380 426 520 444 494 530 238 256 800 238 256
481
450
D
337
KW
120
WW
358
245
A B
KW WW
481
241
WW
versions 150/200
450
450
358
D 56
KW
120
WW
245
KW
481
570
120
Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. The water heaters are available in a vertical version, vertical universal left-right thermo version, horizontal version and horizontal thermo version.
Steel tank treated with thermo-hardening resins (Teflon) or glass-lined using the flow-coating method (850C) depending on the model and/ or version. Armoured copper heating element fitted on a 1 14 coupling. Corrosion-proof magnesium anode. Regulation and safety rod thermostat. LED indicator light. External casing made of sheet metal coated with epoxy powder paint. CFC and HCFC-free polyurethane (PU) foam insulation layer. IPX4 protective cover over electrical parts (IPX2 for versions V/T 50-80-100). Stored water temperature indicator.
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
Coil fittings
kW
1,2
V~
230
min
245
C
75
MPa
0,8
kg
26,5
KW-WW
R
PV-PR
Rp
mm
mm
mm
mm
100
1,2
230
306
75
0,8
31,6
Rp
A D PV 450 362 PR
KW WW
481
120
140 200
245
57
floor-standing, storage
Interline
series 120-160-200-300-400-500-600
Floor-standing electric storage water heaters are designed to meet the highest expectations as regards quality in observance of European and international standards. The insulation layer is made of very thick high-density polyurethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use.
Steel tank, glass-lined using the flow-coating method (850C). 134 mm front inspection hatch. Corrosion-proof magnesium anode. Armoured copper heating element fitted on the hatch. Regulation and safety thermostat. External coloured plastic (PVC) coating. CFC and HCFC-free very thick polyurethane (PU) foam insulation layer. IPX5 protective cover over electrical parts. Stored water temperature indicator.
Accessories on page 60
Capacity
Power
Voltage
Insul. thickness
Net weight
Hydraulic fittings
Recirculation
l ISS 120 ISS 160 ISS 200 ISS 300 ISS 300/3 ISS 400/3 ISS 500/3 ISS 600/3
120 160 200 300 300 400 500 600
kW
1,5 2,0 2,0 3,0 3,0 4,0 5,0 5,0
V~
230 230 230 230 400/3 400/3 400/3 400/3
min
294 294 367 367 367 367 367 440
mm
50 50 50 50 50 50 50 50
kWh/24h
1,50 1,70 2,00 2,40 2,40 2,80 3,30 3,60
C
75 75 75 75 75 75 75 75
MPa
1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0
kg
38 46 53 77 77 99 115 176
KW-WW
Rp Rp Rp Rp 1 Rp 1 Rp 1 Rp 1 Rp 1
Z
Rp Rp Rp Rp 1 Rp 1 Rp 1 Rp 1 Rp 1
mm
mm
mm
854
mm
mm
mm
720 922
610 620
150 486
610 620 1329 150 651 1195 650 675 1560 148 828 1408 650 675 1560 148 828 1408 750 775 1553 162 782 1387 750 775 1818 162 932 1652 810 832 1819 124 871 1659
A
WW
Z C F E
KW
58
Accessories on page 60
Capacity
Insul. thickness
Net Weight
Hydraulic fittings
Recirculation
mm
>100 >100
C
75 75
MPa
1,0 1,0
kg
146 170
KW-WW
Rp 1 Rp 1
Z
Rp 1 Rp 1
mm
880 880
mm
925 925
mm
1865 2245
mm
191 191
mm
mm
A
WW
F E
KW
59
interline
070265
070266
interline
070267
070268
070269
Free Standing
070137
070138
070136
interline
030528
030525
60
Magnesium anode
Featured in all the models in the range, this anode makes for effective electrochemical tank protection.
Environmentally friendly
We strive to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbons (CFC-HCFC) in the insulation layer and makes continuous efforts to use recyclable components.
61
Wood-fired
Wood-fired storage water heaters are designed to produce water where traditional sources of energy are unavailable or simply to use renewable forms of energy while respecting the environment. Electric or thermo-electric versions are available.
Steel tank, glass-lined using the flow-coating method (850C). Corrosion-proof magnesium anode. Combustion chamber made of refractory material with pull-out ash collecting device. Enamelled sheet metal external combustion chamber coating. Mineral wool insulation layer for reduced heat loss. Armoured copper heating element, regulation and safety rod thermostat (wood-electric version only). External casing made of sheet metal coated with epoxy powder paint. Stored water temperature indicator. Electric and thermo-electric versions available.
Capacity
Power
Voltage
Net Weight
Hydraulic fittings
Coil fittings
l LG LGE LGE/T
80 80 80
kW
1,2 1,2
V~
230 230
min
245 245
C
90 90 90
MPa
0,8 0,8 0,8
kg
46 46 49
KW-WW
R R R
PV-PR
Rp
Note: LG = wood-fired version / LGE = wood-electric version / LGE/T = thermo-electric wood version
89 82
89 82
PV
1468
1468
450 PR 613
62
General remarks
All STYLEBOILER appliances conform to European Directives. The gas appliances are devised and specifically approved for the use of standard fuels. All STYLEBOILER appliances made at the S.Maria di Zevio (VR) plant are designed and built in compliance with international quality standards ISO 9001/2000 and conform to article 3.3 of European Directive 97/23/EEC (PED).
Styleboiler is in a position to boast a consolidated experience in the challenging world of protective coatings for steel tanks devised to store domestic hot water, thanks to over twenty years of doing business in the design and manufacture of storage water heaters for the production of hot water.
These appliances are approved for indoor installation only. Installation must be performed and certified by authorised technicians only, in accordance with the law. A hydraulic safety group compliant with EN 1487 or the equivalent must be fitted on all appliances. The water temperature adjustment allows the energy consumption to be optimised according to the well-being required. However, it is advisable to prevent the temperature of the water stored from being too low, in order to avoid the proliferation of bacteria that cause Legionnaires disease. To this end, here are a few general precautions to take: Keep the hot water inside the appliance at a temperature of no less than 50 C; In the event of prolonged absences, allow water to run freely from taps and showers for a few minutes; Keep shower heads and taps free of limescale build-ups. The manufacturer will not be held liable in the event of uses other than those specified.
Styleboiler offers an extensive range of electric, gas and wood-fired storage water heaters and indirect cylinders to cater for all hot water requirements, both at home as well as in industrial or communal settings. The classical product range including boilers manufactured with glass-lined steel has been joined by a renewed and complete product line, which includes stainless steel boilers. The companys policy, which aims at implementing technologies that do not affect the ecosystem, has led to the design and manufacture of new models that utilise renewable energy sources, such as heat pumps. Owing to this wide range of models, Styleboiler can cover a spectrum of capacities ranging from 10 to over 2.000 litres to guarantee the maximum comfort and well-being of end users.
The range
Styleboiler has always stood for quality; the excellent quality of Styleboiler products is the result of an accurate design process combined with the use of advanced technologies, of carefully selected raw materials, and it is guaranteed by regular checks carried out at every stage of the manufacturing process. Product safety is guaranteed by the observance of applicable laws and product standards, along with the prestigious ISO 9001/2000 certification, which enable Styleboiler to accommodate the needs of the most demanding international markets. Flexibility is another feature that makes Styleboiler the best possible partner for its strong focus on the partnership with its customers, offering customised solutions wherever required.
Technical characteristics
As STYLEBOILER constantly strives to improve its products, the company reserves the right to make changes to the technical characteristics and to discontinue models illustrated in this catalogue without prior notice. The details are purely indicative and are included to help you choose the right appliance for your needs. In addition, the manufacturer denies all responsibility in the event of printing or transcription errors.
Guarantee
STYLEBOILER guarantees the correct operation of its appliances according to the methods stated on the guarantee certificates included with the appliances and always in compliance with the applicable Laws in force.
63
Gruppo Giona S.p.A. Via Apollo 11, 1 - 37059 S. Maria di Zevio (Verona) - Italy tel. +39 045 6050099 r.a. - fax +39 045 6050124
Production site: Via Apollo 11, 1 37059 S. Maria di Zevio (Verona) - Italy Loc. Oliero di Sotto 36020 Valstagna (Vicenza) - Italy Via C. Grazioli 27/A 29012 Caorso (Piacenza) - Italy
Internal boiler protection treatments: ZIAC S.p.A. Loc. Speranza 37059 S. Maria di Zevio (Verona) - Italy
Branches: Styleboiler AG/SA/LTD Nordweg 16 - Chemin du nord 16 02502 Biel/Bienne - Switzerland Style System Technik Gmbh Leinenweberstrae, 8 48317 Drensteinfurt - Germany
www.studiocamelot.it