Electric Cables
Data Cables
Copper Rod
Head Office Mokcheon Factory Seoul Office Busan Office Daegu Office
#569, Boseong-ri, Pungse-Myeon, Cheonan-Ci, Chungnam, Korea / Tel : +82-41-559-4800, Fax : +82-41-566-7919 #242-2, Sosa-ri, Mokcheon-eup, Cheonan-Ci, Chungnam, Korea / Tel : +82-41-566-5641, Fax : +82-41-566-5863 Bently Bldg. 2F, #106-2 Yangjae-dong, Seocho-gu, Seoul, Korea / Tel : +82-2-580-4500, Fax : +82-2-587-1108 / 9 Haebong Bldg. 7F, #1146-7, Choryang-dong, Dong-gu, Busan, Korea / Tel : +82-51-465-7906, Fax : +82-51-462-7759 LS Bldg. 2F, #9-10, Dongmun-dong, Jung-gu, Daegu, Korea / Tel : +82-53-252-9513, Fax : +82-53-252-9515
f a
Your Dream
(Environment Management) and OHSAS 18001 (Safety and Healthy working Environment Management) standards. We continue to strive for a pace setter in cable manufacturing industry by implementing state of art R&D Center, best practice HR Program, and a new ERP initiative. A mission to deliver light, energy, and information to global communities - JS Cable A great leap into the future, relentless pursue for customer value - JS Cable With our customers, we devote our full attention to make a better world tomorrow.
We supply our best quality products to markets all over the world.
C o m p a n y
1968 1978 1984 1987 1990 1992 1995 2000 2001 The company incorporated in the name of YONHAP CABLE CO., LTD.
P r o f i l e
Designated as a specialized factory for shipbuilding materials & equipment. Stock listed for public subscription. Moved to new constructed factory site located in Cheon-An Communication cable plant completed in Mokchon. Operation of the copper smelting furnace plant commenced. ISO 9001 certification acquired. (LRQA) LAN cable production line started its commercial operation. TL (Telecommunication Leadership) 9000 certification acquired(LRQA). ETL for IEEE 45 Type P Off-shore and Marine structure cables acquired. UL for UL 1309 Type Off-shore and Marine structure cables acquired. 2002 Korean World Class Products Award for Marine Cable in 2002 (Minister of Commerce, Industry and Energy Republic of Korea) 2004 ISO 14001 certification acquired(LRQA). 2005 OHSAS 18001 certification acquired(LRQA). The corporate governance of the company acquired by LS Group
C o t e n t s
Construction Tables of Shipboard Cables
Power and Lighting Use(Normal Condition) Power and Lighting Use(High Temperature) Control and Signal Use(Normal Condition) Telephone and Instrumentation Use Portable or Flexible Use Switchboard Wire
09 13 14 17 20 21
Technical Information
Identification methods of cores Maximum Working Voltage and Test Voltage Current Rating Calculation of Voltage Drop
24 24 25 29 30
www.jscable.co.kr
Symbol
0.6/1kV DSRC 0.6/1kV TSRC
Table No.
0.6/1kV DPY 0.6/1kV DPYC 0.6/1kV DPYCY 0.6/1kV FA-DPY 0.6/1kV FA-DPYC 0.6/1kV FA-DPYCY 2
Symbol
250V MPY 250V MPYC 250V MPYCY 250V FA-MPY 250V FA-MPYC 250V FA-MPYCY
Table No.
0.6/1kV TPY 0.6/1kV TPYC 0.6/1kV TPYCY 0.6/1kV FA-TPY 0.6/1kV FA-TPYC 0.6/1kV FA-TPYCY 3
Multi core, EPR insulated, PVC sheathed and steel wire braided cable Multi core, EPR insulated, PVC sheathed and steel wire braided cable with protective covering Multi core, EPR insulated and PVC sheathed flame retardant cable Multi core, EPR insulated, PVC sheathed and steel wire braided flame retardant cable Multi core, EPR insulated, PVC sheathed and steel wire braided flame retardant cable with protective covering Multi core, EPR insulated, PVC sheathed and steel wire braided cable with common shield
Multi core, EPR insulated, PVC sheathed, steel wire braided and protective covered cable with common shield Multi core, EPR insulated, PVC sheathed and steel wire braided flame retardant cable with common shield Multi core, EPR insulated, PVC sheathed, steel wire braided and protective covered flame retardant cable with common shield 4 Multi core, EPR insulated, PVC sheathed and steel wire braided cable with individual shield Multi core, EPR insulated, PVC sheathed, steel wire braided and protective covered cable with individual shield Multi core, EPR insulated, PVC sheathed and steel wire braided flame retardant cable with individual shield Multi core, EPR insulated, PVC sheathed, steel wire braided and protective covered flame retardant cable with individual shield
250V FA-MPYCS
250V FA-MPYCYS
0.6/1kV FA-DPYCS
0.6/1kV FA-DPYCYS
0.6/1kV FA-TPYCS
250V FA-MPYC-S
0.6/1kV FA-TPYCYS
250V FA-MPYCY-S
04/05
www.jscable.co.kr
Symbol
250V TTY 250V TTYC 250V TTYCY 250V FA-TTY 250V FA-TTYC 250V FA-TTYCY
Table No.
0.6/1kV T P Y C Y - S
Voltage 3 Core for Power and Lighting
10
FA S D T
Flame retardant Single core for power and lighting Double core for power and lighting Three core for power and lighting
F M TT P
Four core for power and lighting Multi core for control and signal Telephone and instrumentation Portable or flexible
Symbol
0.6/1kV DPNP 0.6/1kV TPNP 0.6/1kV FPNP 0.6/1kV SCP 0.6/1kV SYP
Table No.
12
Sheath Y N
PVC PCP
Armouring C
Steel Wire
Protective covering Y
PVC
Otherwise S -S
Common Shield Individual Core or Pair Shield Earth Wire
13 14
SR Silicone Rubber
Y C PVC
E
FR-XLPE
3. The meaning of letterings used in the symbols in above Tables are as following Table 1 and 2.
06/07
Shipboard Cables
JIS C 3410(1999) / IEC 60092 - 350
www.jscable.co.kr
TABLE 1
0.6 / 1kV EP Rubber Insulated PVC Sheathed Cables-Armoured Flame Retardant Conductor
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Tests
T y p e s o f S h i p b o a r d C a b l e s C o n f o r m i n g t o J I S C - 3 4 1 0 ( 1 9 9 9 )
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
Single Conductor
Conductor Size mm
2
SPYCY FA-SPYCY mm
9.0 9.4 10.0 10.5 11.7 12.9 14.8 16.2 18.1 20.9 23.0 24.8 27.0 29.6 33.1 36.6
Weight (Approx.) Insulation Current Carrying Capacity (Max.) Resistance SPYC SPYCY at 45 (20) FA-SPYC FA-SPYCY km
1,300 1,100 900 800 700 600 500 450 450 450 400 350 350 350 350 350
7/0.52 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52
0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3
0.4 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.5
100 120 140 170 225 300 425 535 695 960 1,250 1,510 1,830 2,250 2,910 3,680
135 150 175 205 270 350 485 605 775 1,080 1,360 1,650 1,980 2,420 3,110 3,910
20 28 38 48 67 90 145 180 225 275 320 365 415 490 560 120
08/09
Stranding
mm
mm
kg/km
Switchboard Wire
Paint
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
www.jscable.co.kr
TABLE 2
0.6 / 1kV EP Rubber Insulated PVC Sheathed Cables-Armoured Flame Retardant Conductor
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
TABLE 3
0.6 / 1kV EP Rubber Insulated PVC Sheathed Cables-Armoured Flame Retardant Conductor
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Tests
Maximum rated conductor temperature : 85 Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
Tests
Maximum rated conductor temperature : 85 Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
Two Conductor
Overall Diameter Conductor Size mm
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185
2
Three Conductor
DPYC FA-DPYC mm
11.7 12.8 13.9 15.2 17.1 19.4 23.0 25.5 29.4 35.1 39.1 42.7 46.8 51.8
DPY FA-DPY mm
10.4 11.5 12.6 13.9 15.8 18.1 21.7 24.2 28.1 33.3 37.3 40.9 45.0 50.0
Weight (Approx.) Insulation Current Carrying Resistance DPY DPYCY Capacity (Max.) DPYC DPYCY FA-DPYCY (20) FA-DPY FA-DPYC FA-DPYCY at 45 mm
13.7 14.8 15.9 17.4 19.3 21.8 25.6 28.1 32.2 38.5 42.7 46.5 50.8 56.0
TPY FA-TPY mm
11.2 12.2 13.4 14.8 17.0 19.5 23.4 26.1 30.2 35.8 40.1 44.0 48.4 53.7
TPYC FA-TPYC mm
12.5 13.5 14.7 16.4 18.3 20.8 24.7 27.4 32.0 37.6 41.9 45.8 50.2 55.5
Weight (Approx.) Insulation Current Carrying Resistance TPY TPYCY Capacity (Max.) TPYC TPYCY FA-TPYCY (20) FA-TPY FA-TPYC FA-TPYCY at 45 mm
14.5 15.5 16.9 18.3 20.7 23.2 27.3 30.2 35.0 41.0 45.5 49.6 54.2 59.7
7/0.52 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52
0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.6 1.7 1.9
0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.6 1.7 1.9
0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.3 1.5 1.6 1.7 1.8 1.9
1,300 1,100 900 800 700 600 500 450 450 450 400 350 350 350
120 155 200 255 360 515 770 1,010 1,360 1,930 2,550 3,150 3,840 4,780
205 250 300 370 490 660 945 1,200 1,580 2,300 2,960 3,600 4,330 5,330
260 310 365 445 575 765 1,080 1,350 1,770 2,570 3,280 3,970 4,750 5,810
7/0.52 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52
0.5 0.5 0.6 0.6 0.7 0.8 1.0 1.1 1.3 1.5 1.6 1.7 1.8 1.9
0.5 0.5 0.6 0.6 0.7 0.8 1.0 1.1 1.3 1.5 1.6 1.7 1.8 1.9
0.6 0.6 0.7 0.7 0.8 0.9 1.1 1.2 1.4 1.6 1.7 1.8 1.9 2.0
1,300 1,100 900 800 700 600 500 450 450 450 400 350 350 350
150 195 255 335 485 700 1,060 1,390 1,870 2,660 3,530 4,370 5,340 6,640
245 295 365 455 625 855 1,240 1,600 2,200 3,060 3,980 4,860 5,870 7,230
300 355 440 535 725 970 1,390 1,770 2,420 3,350 4,320 5,250 6,340 7,780
10/11
Stranding
mm
mm
mm
km
kg/km
Stranding
mm
mm
mm
km
kg/km
Switchboard Wire
Paint
Paint
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
www.jscable.co.kr
TABLE 4
0.6 / 1kV EP Rubber Insulated PVC Sheathed Armoured Cables-Common Shielded, Flame Retardant Conductor
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
TABLE 5
0.6 / 1kV Silicone Rubber Insulated Armoured Cables, Flame Retardant Conductor
Insulation
Silicone rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Paint
In case of protective covering cable, paint is dispensable
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Tests
Portable or Flexible Cords
12/13
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
Paint
In case of protective covering cable, paint is dispensable Maximum rated conductor temperature : 85
Tests
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
Single Conductor
No. of Cores Conductor Size mm
1.5 2 2.5 4 1.5 3 2.5 4
2
Two Conductor
Overall Diameter D(T)PYCYS D(T)PYCS FA-D(T)PYCYS FA-D(T)PYCS mm mm mm mm
12.6 13.5 14.7 13.2 14.2 15.7 0.5 0.5 0.6 0.5 0.6 0.6 14.6 15.5 16.9 15.2 16.4 17.9 0.6 0.6 0.7 0.6 0.7 0.7
mm2
1.5 2 2.5 4 1.5 3 2.5 4
Stranding
7/0.52 7/0.67 7/0.85 7/0.52 7/0.67 7/0.85
mm
1.0 1.0 1.0 1.0 1.0 1.0
mm
11.3 12.2 13.3 12.0 13.0 14.2
mm
0.5 0.5 0.5 0.5 0.5 0.6
km
600 500 400 600 500 400
A
20 27 36 17 22 29
17 24 32 14 20 27
Stranding
Weight (Approx.) Current Carrying Insulation Resistance D(T)PYCS D(T)PYCYS Capacity (Max.) at 45 (20) FA-D(T)PYCS FA-D(T)PYCYS A kg/km km
No. of Cores
Conductor Size
Thickness of Insulation
Switchboard Wire
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
www.jscable.co.kr
TABLE 6
250V EP Rubber Insulated PVC Sheathed Cables-Armoured Flame Retardant Conductor
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
TABLE 7
250V EP Rubber Insulated PVC Sheathed Cables-Armoured Common Shielded Flame Retardant Conductor
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Shield(Common)
Tinned copper wire braid shield shall be applied over the core assembly
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Tests
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
Paint
In case of protective covering cable, paint is dispensable
Two Conductor
No. of Cores Conductor Size mm2
2 4 7 12 19 27 37 44 77 1 1 1 1 1 1 1 1 1
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable) Weight (Approx.) Insulation Current Carrying Resistance MPY MPYC MPYCY Capacity (Max.) MPYC FA-MPYC MPYCY FA-MPYCY (20) FA-MPY FA-MPYC FA-MPYCY at 45 mm
10.0 11.2 13.2 16.8 19.6 23.4 26.1 29.3 37.7
Overall Diameter
Single Conductor
No. of Cores
2 4 7 12 19 27 37 44
MPY FA-MPY mm
8.7 9.9 11.9 15.5 18.3 22.1 24.8 28.0 35.9
14 11 9 7 6 5 4 3 3
Stranding
7/0.43 7/0.43 7/0.43 7/0.43 7/0.43 7/0.43 7/0.43 7/0.43
mm
9.4 10.6 12.6 16.3 19.3 23.0 25.7 28.9
14 11 9 7 6 4 3 5
14/15
Stranding
mm
mm
mm
mm
km
kg/km
Weight (Approx.) Current Carrying Insulation Resistance MPYCS MPYCYS Capacity (Max.) at 45 (20) FA-MPYCS FA-MPYCYS A kg/km km
Switchboard Wire
Tests
Paint
www.jscable.co.kr
TABLE 8
250V EP Rubber Insulated PVC Sheathed Cables-Armoured Individual Shielded Flame Retardant Conductor
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
TABLE 9
250V PVC Insulated PVC Sheathed Cables-Armoured Flame Retardant Conductor
Insulation
PVC insulation applied on the conductor Core identification shall meet JIS C 3410
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Shield(Individual)
Tinned copper wire braid shield shall be applied over the each core.
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Tests
Paint
In case of protective covering cable, paint is dispensable
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
Single Conductor
No. of Cores Conductor Size mm
2 4 7 12 19 27 37 44 1 1 1 1 1 1 1 1
2
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable) Overall Diameter MPYCY-S MPYC-S FA-MPYCY-S FA-MPYC-S mm mm mm mm
11.2 12.9 15.2 19.5 22.8 27.3 30.5 35.0 0.4 0.5 0.6 0.8 0.9 1.1 1.2 1.4 13.2 14.9 17.4 21.9 25.4 30.1 33.5 38.4 0.5 0.6 0.7 0.9 1.0 1.2 1.3 1.5
Single Conductor
No. of Pairs, No. of Triads Cores Quads
1 1T 1Q 4 7 10 14 19 24 30 37 48 2 3 4 8 14 20 28 38 48 60 74 96
14 11 9 7 6 5 4 3
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75
7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37
7.9 8.6 9.3 14.2 16.9 21.7 23.5 26.4 31.9 34.0 36.9 42.8
0.4 0.4 0.4 0.6 0.7 0.9 1.0 1.1 1.3 1.4 1.5 1.7
9.2 9.9 10.6 15.5 18.2 23.0 24.8 27.7 33.7 35.8 38.7 44.6
0.4 0.4 0.4 0.6 0.7 0.9 1.0 1.1 1.3 1.4 1.5 1.7
11.0 11.7 12.6 17.7 20.6 25.6 27.4 30.5 36.7 39.2 42.3 48.4
0.4 0.5 0.5 0.7 0.8 1.0 1.1 1.2 1.5 1.6 1.6 1.8
300 300 300 300 300 300 300 300 300 300 300 300
70 85 105 205 310 465 585 755 1,030 1,220 1,450 1,910
130 155 180 320 440 640 770 965 1,380 1,590 1,860 2,380
170 205 230 400 545 775 1,140 1,610 1,860 2,170 2,760 920
16/17
Stranding
Weight (Approx.) Current Carrying Insulation Resistance MPYC-S MPYCY-S Capacity (Max.) at 45 (20) FA-MPYC-S FA-MPYCY-S A kg/km km
TTY FA-TTY mm mm
TTYC FA-TTYC mm mm
Stranding
Switchboard Wire
Tests
Paint
Annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
www.jscable.co.kr
TABLE 10
250V PVC Insulated PVC Sheathed Cables-Armoured Common Shielded Flame Retardant Conductor
Annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
TABLE 11
250V PVC Insulated PVC Sheathed Cables-Armoured Individual Shielded Flame Retardant Conductor
Annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
Insulation
PVC insulation applied on the conductor Core identification shall meet JIS C 3410
Insulation
PVC insulation applied on the conductor Core identification shall meet JIS C 3410
Shield(Common)
Annealed copper wire braid shield shall be applied over the pair assembly
Shield (Individual)
Annealed copper wire braid shield shall be applied over the each pair
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Armour
Braided galvanized steel wire in accordance with JIS C 3410
Paint
In case of protective covering cable, paint is dispensable
Paint
In case of protective covering cable, paint is dispensable
Two Conductor
No. of Pairs, Triads Quads
1 1T 1Q 4 7 10 14 19 24 30 37 48
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable) Nominal Dia. over Sheath mm
8.8 9.3 10.0 15.0 17.7 22.8 24.4 27.5 33.1 35.5 38.4 44.3
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1(for normal type cable), IEC 60332-3 CAT A(for FA- type cable)
No. of Cores
2 3 4 8 14 20 28 38 48 60 74 96
Conductor Size mm
2
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75
7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37
10.1 10.6 11.3 16.3 19.0 24.1 25.7 28.8 34.9 37.3 40.2 46.1
0.4 0.4 0.5 0.7 0.8 1.0 1.0 1.2 1.4 1.5 1.6 1.7
12.1 12.6 13.3 18.5 21.4 26.7 28.3 31.6 38.3 40.7 43.8 50.1
0.5 0.5 0.5 0.7 0.9 1.1 1.1 1.3 1.5 1.6 1.7 1.8
300 300 300 300 300 300 300 300 300 300 300 300
180 205 230 405 545 800 935 1,160 1,600 1,950 2,250 2,830
230 255 285 490 650 945 1090 1,340 1,860 2,230 2,570 3,240
No. of Pairs
4 7 10 14 19 24 30 37 48
No. of Cores
8 14 20 28 38 48 60 74 96
Stranding
7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37
kg/km
490 690 1,070 1,400 1,780 2,300 2,680 3,170 4,090 595 825 1,250 2,050 2,640 3,060 3,600 4,630 1,610
18/19
Stranding
Two Conductor
Overall Diameter Insulation Resistance TTYCY-S TTYC-S (20) FA-TTYCY-S FA-TTYC-S mm mm mm mm km Weight (Approx.) TTYC-S TTYCY-S FA-TTYC-S FA-TTYCY-S
Switchboard Wire
Tests
Tests
www.jscable.co.kr
Switchboard Wire
TABLE 12
0.6 / 1kV EP Rubber Insulated PCP Sheathed Flexible Cords Conductor
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
TABLE 13
0.6 / 1kV XLPE Insulated Wire(SCP) Conductor
Tinned, annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
Insulation
XLPE insulation applied on the conductor The XPLE complies with the JIS C 3410
Insulation
EP rubber insulation applied on the conductor Core identification shall meet JIS C 3410
Sheath
The PCP sheath applied over the cabled core The PCP complies with the JIS C 3410
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1
Tests
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1
Two Conductor
No. of Cores Conductor Size mm2
0.75 1 1.5 2.5 4 6 0.75 1 1.5 2.5 4 6 0.75 1 1.5 2.5 4 6
Single Conductor
Thickness of Insulation mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Conductor Size mm
1.5 2.5 4 6 10 16 25 35 50 70 95
2
Thickness of Insulation mm
0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.4 1.4 1.6 1.7
Stranding
24/0.20 32/0.20 30/0.25 49/0.25 55/0.30 82/0.30 24/0.20 32/0.20 30/0.25 49/0.25 55/0.30 82/0.30 24/0.20 32/0.20 30/0.25 49/0.25 55/0.30 82/0.30
0.4 0.4 0.4 0.5 0.5 0.6 0.4 0.4 0.5 0.5 0.6 0.6 0.5 0.5 0.5 0.6 0.6 0.7
Stranding
30/0.25 49/0.25 55/0.30 82/0.30 80/0.40 7/18/0.40 7/28/0.40 7/39/0.40 19/21/0.40 19/19/0.50 19/25/0.50
A
20 28 38 48 67 90 145 180 225 275 120
0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.6 0.7
70 70 60 50 40 30 30 30 30 30 30
20/21
mm
mm
Switchboard Wire
Tests
Shipboard Cables
JIS C 3410(1999) / IEC 60092 - 350
www.jscable.co.kr
Switchboard Wire
Power and Lighting Cables Control and Signal Cables Telephone and Instrumentation Cables Portable or Flexible Cords
TABLE 14
0.6 / 1kV PVC Insulated Wire (SYP) Conductor
Annealed copper wires per IEC Pub. 60228 Stranding as shown in table below
Insulation
PVC insulation applied on the conductor The PVC complies with the JIS C 3410
Tests
Meet applicable test requirements in JIS C 3410 or IEC 60092-350, IEC 60332-1
T y p e s
o f
S h i p b o a r d
C a b l e s
C o n f o r m i n g
t o
J I S
C - 3 4 1 0 ( 1 9 9 9 )
Switchboard Wire
Technical Information of Shipboard Cables Approval by Ship Classification Society
Single Conductor
Conductor Size mm2
0.75 1 1.5 2.5 4 6 10 16
Thickness of Insulation mm
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3
Weight (Approx.) A
11 13 17 24 32 41 57 76
> > >
Stranding
24/0.20 32/0.20 30/0.25 49/0.25 55/0.30 82/0.30 80/0.40 7/18/0.40
mm
0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4
3. Current Rating
Identification Code a) Current ratings in continuous service for single cables. (ambient temperature 45) Note 1 - The current ratings , in amperes, have been calculated for each nominal cross-sectional area A, in square millimeters, with the formula:
Double Core : Black & White Black, White & Red Black, White, Red & Green
Identification Method
Colored insulation
Three Core Four Core Colored compound over the glass yarn braid
: :
Where is a coefficient related to the maximum permissible service temperature of the conductor as follows:
Attached Table 1.
Maximum Permissible Temperature of the Conductor
60 9.5 8 75 13.5 13 85 16 16 95 18 20
Printed letter on the insulation Number of arabic figures (in some cases, colored identification may be applied)
Values of
Printed letter on the insulation, but color of insulation shall be white, and one core of each pair shall be imprinted by specified color ink
2.5mm2 2.5mm2
Core Number
19 27 37 44
Correction Factor
0.4 0.3 0.25 0.2
2 3~4 7
d.c
450V
12
0.6 / 1 kV
0.6 / 1 kV
0.9 / 1.5 kV
3500 / 5
40
1.15 1.08 1.06 1.05
45
1.00 1.00 1.00 1.00
50
0.82 0.91 0.94 0.95
55
0.82 0.87 0.89
60
0.71 0.79 0.84
65
0.58 0.71 0.77
70
0.61 0.71
75
0.50 0.63
80
0.55
85
0.45
75 85 95
24/25
c) If ambient temperature differ from 45, the values shown in Table. should be multiplied by the following factors.
Switchboard Wire
b) In case of multi-core cable, the values shown in Table 1. shall be multiplied by following correction factors.
Single Core :
Black
= A 0.625
Ambient Temperature 40 A
14 12 9 7 6 5 4 3 3
45 A
14 11 9 7 6 5 4 3 3
50 A
13 11 9 7 5 5 4 3 3
Telephone and Instrumentation Cables Control and Signal Cables
(40) mm
2
(45)
Short Time
30 1 min hour
20 28 38 48 67 90 21 30 40 51 71 96 21 30 40 51 71 95 19 26 36 45 63 85
(50)
Short Time
30 1 min hour
20 28 38 48 67 90 20 28 38 48 67 90 18 25 34 43 60 81
(40)
Short Time
30 1 min hour
19 27 37 47 66 91 19 27 36 46 64 86 17 24 32 41 57 77
(45)
Short Time
30 1 min hour
18 25 35 44 63 86 18 25 34 43 60 81 16 23 31 39 55 73 98
(50)
Short Time
30 1 min hour
17 24 33 43 60 82 17 24 33 41 58 78 15 21 28 36 50 67 89
(40)
Short Time
30 1 min hour
16 22 30 39 55 76 106 16 22 30 38 53 71 96 14 20 27 34 47 63 84
(45)
Short Time
30 1 min hour
15 21 29 37 52 72 100 15 21 28 36 50 67 91 13 19 26 32 45 60 81 97
(50)
Short Time
30 1 min hour
14 20 28 35 50 69 96 14 20 27 34 48 65 87
Short Time
30 1 min hour
1.5 2.5 4 6 10 16 25 35 50 70 95
21 30 42 51 71 95
22 31 43 54 75
22 31 43 54 75
Note 1. The current rating value in Table 4. are for 6 cables or less bunched or laid together in that formation.
When more than 6 cables and bunched or laid close together, a correction factor 0.85 should be applied to the value given in table 4. 2. In case of a.c, the frequency is 60Hz.
101 101
127 135 135 120 128 127 113 121 119 108 126 116 102 119 110
114 105
Double Core 50
23 30 40 52 71
Three Core 50
19 26 34 44 61
45
24 32 42 55 75
40
21 29 37 49 67
45
20 27 36 47 64
40
18 24 31 40 55
45
17 22 29 39 53
50
16 21 28 50 37
154 163 163 145 156 154 136 147 144 131 156 142 123 147 134 118 142 128 108 131 118 102 124 111
119 107
191 202 202 180 196 191 169 184 179 162 203 179 153 191 169 147 183 162 134 172 149 126 162 141 121 156 135 239 253 253 225 249 239 212 234 225 202 266 229 191 251 216 184 241 207 167 225 191 158 212 180 151 204 173 292 311 311 275 312 293 259 293 276 248 345 289 234 325 273 224 312 262 204 293 243 193 276 229 185 265 220
120 339 364 364 320 369 343 301 347 322 288 417 345 272 394 325 261 379 312 237 355 290 224 335 373 215 321 262 150 387 418 418 365 431 394 343 405 371 329 496 404 310 468 381 298 449 366 271 422 340 256 399 321 245 383 308 185 440 479 479 415 503 452 390 473 425 374 593 475 353 559 448 339 537 430 308 505 401 291 476 379 279 457 363
Note 1. The value in Table. are for 6 cables or less bunched or laid together in that formation.
When more than 6 cables and bunched or laid close together, a correction factor 0.85 should be applied to the value given in table. 2. In case of a,c, the frequency is 60Hz
Double Core 50
10 13 16 23 31 39
Three Core 50
8 11 13 19 26 32
45
11 14 17 24 32 41
40
10 12 15 21 28 36
45
9 11 14 20 27 34
40
10 12 15 21 28 36
45
9 11 14 20 27 34
50
8 11 13 19 26 32
26/27
Switchboard Wire
Power and Lighting Cables Control and Signal Cables Telephone and Instrumentation Cables Portable or Flexible Cords Switchboard Wire
The following formulas are for calculation of the voltage drop in each circuit distribution. 1) D.C. circuit Rdc x 2L x V 2) A.C. circuit Voltage drop rate of single-phase A.C. = Rac x 2L x V Voltage drop rate of three-phase A.C. = Rac x 2L x V x x x 100(%)
Ambient Temperature 40 A
21 30 40 51 71 95 127 154 191 239 292
45 A
20 28 38 48 67 90 120 145 180 225 275
50 A
19 26 36 45 63 85 113 136 169 212 259
x 100(%)
Control and Signal Cables
3
2
16 25 35 50 70 95
Where
L : Cable Length(km)
V : Circuit Voltage(V)
I : Current(A)
Rdc : D.C. Resistance at Maximum Rated Conductor Temperature (see following table) Rac : A.C. Resistance at Maximum Rated Conductor Temperature (see following table) : Inductive Voltage Drop Coefficient (see following table)
Note 1. The value in Table 7. are for 6 cables or less bunched or laid together in that formation.
When more than 6 cables and bunched or laid close together, a correction factor 0.85 should be applied to the value given in table. 2. In case of a.c, the frequency is 60Hz.
Attached Table 8. Current ratings of PVC insulated wire for controlling machines and apparatus
Nominal Conductor Area (mm2)
0.75 1
Ambient Temperature 40 A
12 14 18 26 35 44 62 82
1.5
12.200 7.500 4.700 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.076 0.061
15.3 9.5 5.90 3.90 2.31 1.46 0.92 0.664 0.491 0.339 0.245 0.193 0.158 0.126 0.096 0.076
15.3 9.5 5.90 3.90 2.31 1.46 0.92 0.664 0.491 0.339 0.247 0.195 0.161 0.129 0.099 0.081
0.357 0.332 0.309 0.292 0.272 0.258 0.254 0.246 0.245 0.237 0.235 0.230 0.231 0.230 0.229 0.228
45 A
11 13 17 24 32 41 57 76
50 A
10 12 15 22 29 37 52 69
2.5 4 6 10 16
1.5 2.5 4 6 10 16
Note 1. The value in Table 8. are for 6 cables or less bunched or laid together in that formation.
When more than 6 cables and bunched or laid close together, a correction factor 0.85 should be applied to the value given in table. 2. In case of a.c, the frequency is 60Hz.
28/29
1.02
Switchboard Wire
mm
/km
/km
/km
mH/km
100%
95%
90%
85%
80%
75%
70%
x x 100(%)
Power and Lighting Cables Control and Signal Cables Telephone and Instrumentation Cables Portable or Flexible Cords Switchboard Wire
Power and Lighting Cables Control and Signal Cables Telephone and Instrumentation Cables Portable or Flexible Cords Switchboard Wire Technical Information of Shipboard Cables
The Shipboard cables in accordance with KS C-3326 and JIS C 3410 have been accepted by ship classification societies such as DNV, ABS, NK, LR and KR moreover we got the certificate of Type Approval, Homologation or Test Report which are issued to such cables by DNV, LR, NK, ABS and KR.