Sie sind auf Seite 1von 12

Streamlined workload management Testing handled with ease STATs prioritized fast

Lifting the

of labs like yours

Manage your workload with

less effort

Streamlined workload management


Continuous access to reagents, samples and supplies 65 sample load capacity 13 universal bays; up to 7 customizable priority bays Refrigerated reagent carousel features 25 reagent positions (100 test kits) Reagents stable onboard for up to 30 days (tracked in hours)

Testing handled with ease


Fewer workflow pauses Simple and easy to operate Low maintenance (10 minutes of daily maintenance) Intuitive ARCHITECT software

STATs prioritized fast


Immediate STAT processing Automatically run priority tests first Consistent turnaround time of 15.6 minutes on STAT assays Up to 7 customizable priority bays

ARCHITECT i1000SR
An agile immunoassay analyzer specifically designed for the complex workload requirements of labs like yours.

From the ground up, built for

productivity
7 4 3 6 5 2 8

10

Continuous access reagent loading/ unloading and customizable sample bays for enhanced productivity Exceptional workload management for timely and accurate patient results

1 Reaction vessel hopper (300 RV capacity)

9
2 Bar code reader (reagents and samples) 3 Robotic Sample Handler (RSH)
transport robot

4 Wash zone 5 Sample aspiration platform 6 Patented probe wash cup 7 Pipettor 8 RSH universal bays (65 sample load-up
capacity; 13 universal bays, including up to 7 customizable priority bays)

9 Refrigerated reagent carousel (features 25


reagent positions, 100 test kits; reagents stable onboard for up to 30 days)
10 RSH intuitive indicator lights

ARCHITECT: Rise above

everyday challenges
True Family Commonality
The ARCHITECT i1000SR exemplifies the design philosophy of the ARCHITECT family of analyzers
ARCHITECT i1000SR reagent carrier

Identical CHEMIFLEX technology, 100 test kit reagents, assay protocols and consumables Identical ARCHITECT software Identical universal ARCHITECT sample carrier The benefits: equivalent patient results across all ARCHITECT immunoassay instruments and a simple, consistent user experience
ARCHITECT software

ARCHITECT universal sample carrier

ARCHITECT ci4100 *

Enhanced System and Assay Dynamics


CHEMIFLEX technology with flexible assay protocols delivers exceptional detection and improved sensitivity New patented wash cup design and wash algorithm effectively control sample carryover (<0.1 ppm tube to tube) Pressure differential technology enables detection of clots, bubbles and insufficient sample volume to reduce analytical error and improve patient safety The benefits: certainty and confidence in the clinical results

Integration Without Compromise


Conceived and designed for future integration with the c4000* chemistry analyzer ci4100 * Fast STATs: The ARCHITECT Robotic Sample Handler (RSH) provides load on the fly continuous access to both reagents and samples and allows the lab to prioritize tests through customizable priority bays The benefits: handle the most urgent samples first without compromising your routine testing

ARCHITECT i1000SR wash cup

*In development

Product Specifications
Physical Dimensions (H x W x D) Weight Power Requirements 49'' x 59'' x 30'' (124.5 x 149.86 x 76.2 cm) 636 lb/288 kg 110-120 volts with 20 amp dedicated circuit breaker or 200-240 volts with 10 amp dedicated circuit breaker Maximum power consumption Heat output Operating temperature Noise specifications NCCLS Type II water Liquid Output Onboard buffer capacity Onboard RV storage Onboard liquid waste capacity Onboard solid waste (RV) capacity Trigger/pre-trigger Up to 100 tests per hour (1-Step STAT Assays) Sample load-up Reagent Onboard reagent CHEMIFLEX Serum, plasma, urine Height: 72-102 mm, Diameter: 8.25-16.1 mm Yes (50 L dead volume) 10-150 L, average: 50 L Yes <0.1 parts per million All liquid ready-to-use Yes Yes Yes, AbbottLink 65 sample capacity with up to 35 STAT positions 25, 100 test kits (2,500 tests) 30 days (tracked in hours)

1760 VA-2KVA 2113 BTU/hr average 59-86F (15-30C) 55 db Required for reconstituting buffer Floor drain or onboard liquid waste container 1.5 liters/hour maximum 12 liter capacity Up to 300 RVs 10 liters 1,000 RVs 3,000 and 9,000 tests

Environmental

Waste Consumables

Throughput Capacity Stability Methods Sample Types Sample Tubes Pediatric Sample Cup Sample Volume Automatic Dilution Sample-to-sample Carryover Reagent Type Sample Clot and Bubble Detection Reagent Pressure Monitoring Remote System Diagnostics

ARCHITECT, i1000SR, ci4100, c4000, AbbottLink and CHEMIFLEX are trademarks of Abbott Laboratories.

www.abbottdiagnostics.com 1-800-323-9100
2008 Abbott Laboratories AR-08-14812/v1-5 May Printed in USA

CHEMIFLEX
Refined chemiluminescence

Patented sulfopropyl group


improves water solubility for enhanced assay performance

detection
redefining performance
Patented sulfonamide leaving group
improves reagent stability

Refining

CHEMIFLEX
Refined chemiluminescence
ARCHITECT i1000SR Reagent Carrier

Enhanced System and Assay Dynamics


CHEMIFLEX: Excellent sensitivities and extended linearities
Low-end TSH Assay Performance
In this study, functional sensitivity was calculated as the concentration of TSH giving a CV of <20%

ARCHITECT Access 2 Centaur E170 Immulite 2000 ECi

<0.005 (6.9 % CV at 0.0049 mIU/L) <0.02 0.039 0.011 0.014 0.004 (15% CV at 0.0056 mIU/L) 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 TSH (mIU/mL)
In this study, the ARCHITECT i2000 and Vitros ECi demonstrated the lowest functional sensitivities, but the ARCHITECT i2000 was the most precise of the methods evaluated, with a CV of 6.9% at a TSH concentration of 0.0049 mIU/L. Source: Rawlins ML, Roberts WL. Clin Chem 2004;50:2338 2344.

ARCHITECT i2000 was the most precise of the methods evaluated

The ARCHITECT i1000SR features advanced CHEMIFLEX technology. It combines refined chemiluminescence detection with flexible assay protocols.
Patented sulfopropyl group improves water solubility for enhanced assay performance Patented sulfonamide leaving group improves reagent stability Allows option of selecting protocol that provides the highest assay performance and clinical accuracy (1 Step, 2 Step, STAT, pre-treatment)

-hCG Dynamic Ranges


Extended linear range reduces the need for dilutions and delivers excellent turnaround time.

ARCHITECT, i1000SR, ci4100, c4000 and CHEMIFLEX are trademarks of Abbott Laboratories.

www.abbottdiagnostics.com 1-800-323-9100
2008 Abbott Laboratories AR-08-14812/v1-5 May Printed in USA

RSH
Robotic Sample Handler

Innovation that boosts your labs

productivity

1
RSH transport robot loads/unloads reagents

2
RSH transport robot lifts urgent samples ahead of routine workload

3
RSH transport robot loads/unloads samples

RSH
Robotic Sample Handler
ARCHITECT i1000SR Reagent Carrier

Robotic Sample Handler (RSH)


The unique design of the RSH on the ARCHITECT i1000SR answers the productivity demands of todays clinical laboratory.

Innovative design for continuous access to reagents and samples Priority samples automatically take precedence over routine ones Priority bays allow for immediate STAT processing 15.6 minute turnaround time on STAT assays Intuitive indicator lights simplify sample handling and reagent loading Number of priority bays can be customized to workflow needs Manages priority, rerun and reflex testing
ARCHITECT universal sample carrier accepts 5, 7 and 10 mL tubes and sample cups

ARCHITECT, i1000SR, ci4100 and c4000 are trademarks of Abbott Laboratories.

www.abbottdiagnostics.com 1-800-323-9100
2008 Abbott Laboratories AR-08-14812/v1-5 May Printed in USA