zl,
(5l!

Holoohane
designer series

o_
CO

()R
9." 6d at2

Skyscape
Create your own outdoor lighting scene. Combine our versatile luminaire slandards wilh any of these 5 largescale classic archileclural lorms (or design your own). Each form encloses a highly etlicient wide-area luminaire.

Enhance your architectural theme.

Sphere
A 32" diameter sphere enclosing the Holophane high etficiency 1100 Series luminaire. This form lends itseli to individual or multiple clusters where the silhouette musl "read" lhe same when
viewed from any direction.

Cube
A 26" cube, cleanly detailed . . . whose basic form is lighlened by the bottom conical glass refractor. lt is especially adaptable to cluster assemblies on a
variety of pole types.

Sphere... on davit type standard becomes a graceful design lement in harmony with a sculptured theme.

Dual cubes on "T" type arm relate strongly to building masses having monolithic forms.

()

These luminaires and standards permit you to enhance the architectural theme without compromising lighting perf ormance, by combining any of the standards and forms to suit the aesthetic requirements of the site. Or, if you prefer, design your own luminaire form. See pages 9 and 10.

Cylinder
A classic 20" diameter form, 30" high whose basic orientation and vertical sh ape make it easy to combine with any ol the pole types. The rugged acrylic surround extends the cylindrical lorm and permits the glass refractor to provide the necessary light output to assure the highest perlormance.

Rectangle
This 20" sq. x 30" high rec-

Hexagon
Multi-faceted surfaces add character. The 20" (across flats) x 30" high unit permits geometric arrangements that lend themselves to more compact groupings. The form is enhanced by a clear acrylic skirt which acts to visually lengthen the basic
element.

tangle's f lat sides permit


orientation o{ the lorm in reestablished for the building and site plan. The acrylic surround ex-

lation to the geometrics

tends the f orm's vertical


dimension to read as a rectangle.

The hexagonal shape and lacets ot these can be

used

to integrate

!-

symmetrically
spaced luminaires can be used to express a more

complex
arch itectura
I

motif.

Mounting arrangements limited only by your imagination.

Maintain design continuity.

The illumination parameiers can be selected to achieve pedestrian safety, area definition or pure esthetic consideration. In any case, the performance of the units selected is unaffected by the mounting method and conf igurations selected.

Multiple variations to combine form and function.


Pole types

0)

t)
6

Superior lighting performance that lasts.


All the forms are simple geometric envelopes enclosing the Holophane high performance wide area luminaire. They all perform the same photometrically, and maintain their efficiency over a long period of time.

QUICK METHOD FOR ESTIMATING POLE/LUMINAIRE REQUIREMENTS.

SUGGESTED LIGHT LEVELS FOR COMMON APPLICATIONS.

A convenient "light module" method has been developed to help you estimate your lighting requirements, Light modules are tabulated below for various pole/luminaire arrangements indicating the average maintained footcandle Ievel provided over a given number of square feet. The modules have been selected on the basis of 5 M.H. spacing between poles. A table of suggested light levels for common applications is
included as a guide.

Application Shopping Center Parking Area Stadium Parking Area lndustrial Plant Parking Area Mall General PIant Security Area Urban Expressway
Business District High

Avg. fc

To estimate your pole/luminaire requirements, knowing the total area to be illuminated and the desired light level, simply calculate using the following equationr
No. of

Traffic

2 5

poles

Total

Modu le

Area v Area

Required fc Module fc

Erample: Given a large parking area 1500'x 800' (1,200,000 It.'?) requiring an illumination level of 5 fc maintained.

Solution: Since the area is quite large and the required light level is high, multiple grouping of luminaires on tall poles olfers the most economical solution.
Therefore, you might select the light module for the estirhate.

60' pole with 4 luminaires as the basis for your


Estimated

of

1,200.000 ., 5 No, Poles - --Ed;00- \ -14- :

Jv

Purcs

Once you have determined the aDDroximate number of ooles_ check the configuration of the arba to see that thev c;n be positioned to provide the required coverase without eiceedins the 5 to 1 pole spacing ratio (300 feet atart).

LIGHT MODULES

Apptoximate Maintained
Average Light Level in

fc'

Mounting Height (Feet)

Unit Area ol Light Module (sq. Ft.)

Number of Luminaires
2

l-=?

4
8.8
5.O

30'
401

22,500
40,000
1.25

4.4
2.50
1-5

6.5 2.4 1.68

5C/

62,500
90,000

0.8 0.56

60'

t.12

2.24

*Based upon use of 1000W halide lamp rated 100,000 lumens and combined light loss factor of 0.75.

Construction and dimension data.

EXCEPTIONAL PERFORMANCE - The wide area luminaire contained within the lorms shown here is shadowless illumination. MAINTAINED EFFICIENCY

highly etlicient and provides optimum unilorm

- All units are open-ventilated, self-cleaning design - proven by years of service. SOLID ENGINEERING -Allforms utilize an inteqrated structural design that firmly locks the enciosinq shell to the optical control core.

t--,"---

I
26'

l-^""

-1

T@
-l-

_L
Sphere Cube Hexagon Rectangle

+@ ,,^.

Cylinder

Cast aluminum detachable ballast enclosure.

Selt'cleaninq
Rugged outer Endurall!'l borosi licate

enclosure.

prismatic

glass reflector.

Side entry slip fitter.

Metal halide, mercury vapor or high pressure sodium lamp.

Sturdy clear acrylic skirt.

- -t-'-.-\ -

i borosilicate prismatic {beam controllinq) glass refractor.


Endural

Design your own Skyscape shape.


The oullines shown here are for your convenience and lo make il easy lo design alternate torms if you wish. The submitlal sheel to obtain
a quolation is on page 10.

Scalel/td"

: 1'

--!F

Cr

scale
MAIL TO: AUOTATIONS DEPT., H0LOPHANE COMPANY'
N. J.

1/s"

=1"

luminaire. Quotation request for special Skyscape 07645 M0NWALE lNC"


Please supply the following information
Area description

Site location Site name


Req'd quote

Titlt
Firm Name
Req'd Shipment Date

date Type Pole: Ouantity Luminaire: quantily

Height

Finish

Enclosure finish

Lamp Type & Wattage

Speciflcations for staerdard steel poles.

L-}:=J, ]r.,
I

-2a"'S

TL as"

-.

raaius

TOP BR,ACKET
1

LUMINAIRE DATA
PROJ. AREA

DESCRIPTION SPHERE
CU BE

COEFF.

WEIGHT

sQ. Fr. OF DRAG

VIT i
!

5.50 4.70 4.30 4.30 4.30

.47 1.30
1.0

98 lbs. 115lbs.
102 lbs. 102 lbs. 102 ibs.

HEXAGON CYLINDER RECTANGLE

.78 1.30

1r
l
:

40 pipe conforming to A.S.L


A53 grade A.

Ali mounting bracket arms are 2" Std. Sched. lM. designation;

t--

Il
"1

STANDARD POLE AND F!XTI.,IRE COMBINATIONS BRACKET TYPE

..48
sEcTi0Ns
l NOTE: Detailed pole data including bending moments, bolt circle sizes, weights and anchor rod dimensions is available upon request. This information is not shown here since the optimum pole design lor any given combination of S KyscApE shapes, bracket configurations and number of luminaires per pole should be made for each SKyscApE system for bes! results. Please provide all pertinentspecifications (mounting height, mounting bracket style, luminaire quantity and luminaire shape) when requesting detailed po,e data.

HEIGHT

NUMEER OF LUMINAIRES

NUMBER OF

TL, TS, SB, FI

40' 50' 60'

1,2,3

ot 4

ANY SHAPE

2 2

DA

30' 40'
30'

(srNGLE)
DA (TWtN)

oNE {1)
ANY SHAPE
TWO (2)

1 1

2
2

ANY SHAPE

Type FT

11

Specification and ordering information.

To order Skyscape series comblnations, slmply identlfy pole type, number of lumlnalres, pole helght, pole linish, luminaire shape, and ballast voltage. Standard catalog numbers include lumlnaires for use with 1000 watt metal hallde lamps, Lumlnalres are also available for 400 watt hlgh pressure sodlum and 1000 watt mercury vapor lamps- lf elther of these is to be used, indicate by lamp description after assembled catalog number.

NUMBER OF LUMINAIRES
F\',LE I ! TE
1

POLE

HEIGHT 30' 40' 50, 60'

POLE t1 FINISH
G P

LUMINAIRE
SHAPES CUB HEX SPH REC CYL 120

BALLAST VOLTAGE
208

240

277

480

foo
|".

l- rL*. l- sBi
TFT
*Bracket arm is 24" **Bracket arm is 48" 154" bracket arm supplied as standard. Other lengths available upon request. ilc Galvanized; P: Prime painted

EXAMPLE OF CATALOG NUMBER ASSEMBLY:


Shown at right is the catalog number derived from table above for a fork-top pole, 50'high, prime painted, with three Rectangle luminaires having 120V ballasts.

FTSSOP-REC-120

Contact your local Holophane sales engineer for application assistance, and computer.aided design and cost studies.

Hp.lgp"h"pndirdin*'Jii,{fr i4"lh#$f#}d[{*,i;"1j.#"
Printed in U.S.A. 777R65.773