Sie sind auf Seite 1von 8

.

'l

EI

(o
ltlt qN
r
..j

INTRODUCING

POSTOP'

ny noroeHANE

Holophane's Vista lll Postop Series provides a truly unique synthesis of attractive, contemporary, styling with outstanding Iighting perlormance. This most impressive combination enables you to develop outstanding lighting solutions in situations where only compromises could previously be achieved. The great llexibility otlered by this line encompasses more than twelve thousand ditferent aesthetic and performance variations, enough to solve any and all lighting problems, from the mosl lunctional to the most decorative.

Design Flexibility

ail
\--;

\,
i,il

Complete interchangeability of Vista lll design elements alfords tremendous freedom of individual prelerence in choosing lrom 3 totally different refractor shapes,6 multiple clusler contours,4 pole heights,2 pole bases,5lamp sizes,3 wall bracket designs,2 pole shapes and uncounted pole colors. This choice permits continuity of both performance and aesthetics for all areas ol application.

Pure Styling Absolutely no nuts, bolts, Iatches or knobs are visible on the outside of the luminaire. All mechanical hardware is totally hidden so that only an uncluttered appearance is presented.

Form and Function Precise prismatic optical control yields high perlormance and enhances appealing luminaire aesthetics.

COPYRIGHT 1970 BY HOLOPHANE COMPANY, INC.

ISOLUX CHART

f .rophano No 260 w lh 100w ll33 4lAlDx de lxe urh re 3mp 4400 runens. rluminalion varues bas

To.onved isolux chart values lor moLnlinq heiqhls olher than

lumens

i 10o! H33 4JA/ox deure wh le Ho ophane No 261 um nal on va ues based on 12 mouninq heLqhl.

amp 4{00

shown, use lhe lollowing m!lli-

V
HEIGHT
8

2.24

10 12

93
1+ '

100
.13 .64

eg

A6
9

/)
9

\;

0
a

4,,

FATIO OF TFANSVERSE DISTANCE

RATIO OF TRANSVERSE OISTANCE TO MOUNTING HEIGHT

Ref

ractor
No.

Spacing Ratio

lightinS
perf{Drrnance
More Light for Less Money
Highly efficient prismatic luminaires limit amount of light emitted upward and redirect such light outward over wider area providing more light where it is needed and reducing number ol luminaires and power required.

260 Square 261 Tapered 262 Ellipse

5:1

Complete Area Coverage Engineered light distribulion is specilically designed lor uniform illumination over wide areas
withoul objectionable hot spots below luminaires.

Total Comlort
Soft even glow ol prismatic relractor eliminates objectionable nighttime harshness by precisely controlling high angle light and by spreading lamp image uniformly over entire refractor surlace.

Choice Of Lamps
To fit your specific requirements the Vista lll line has been designed for use wilh 100 and 175 watt mercury, and 100, or 200 watt incandescent lamps.

1^3/. "

(t
easy access relamping plate

83/q"

I
97/a

15v4"

---l

I
7

internal

no. 262 ellipse refractor

d4----':s::"'il,, cramn

{/ llJ

all optical assemblies Square, Tapered or Elliptical are completely interchangeable

tapered refractor
no.
26.1

1^1h " t--l .--.\ ''''''''''.-

-------)

_T

completelY h idden easily accessible


mercu ry

ballast

F IT
optional decorative pole wiih lins

101/z

wiring hand hole located at top of pole only


no. 260 sq uare refractor

aluminum pole lor 8' , 10' or 12' nominal sing le

luminaire mounting heig hts.


steel pole tot 1O' ,12', ot 14' nominal multi-head

\ o--

\l nnn
||l ililil -<__]l?*

rreehanieal data
lnstallation Ease
Luminaire pole assembly is specifically deslgned lor ease of installation, all components fit together using only pocket tools.

luminaire mounting heig hls

2'bituminized section provided on direct embedment


Poles onlY

optional mistake-proof cast base including three anchor rods on 7" bolt circle

Mistake Proof
Unique integral anchor rod - base plate design makes it impossible to set anchor rods incorrectly.

Maintenance Simplif ied


Components are easily accessible {or maintenance with only a screw driver.

Corrosion Protection
All exposed parts are glass, aluminum orprotected steels wh ile poles for direct bu rial are faclory coated with special anti-corrosive tar base compound.

grommeted wiring h ole

---+

Complete Bug and Moisture Proteclion


Totally gasketed and sealed, Vista lll remains bug and moisture tight. The refractor is automatically cleaned by the natural washing action ol the rain.

vrsTA ill
INSTALLATION

Place pole directly in ground or in cast base preset in concrete. lnsert one p iece socket-ballast assembly in pole top and connect to supply wires3. Place relractor over socket on pole top.
1.

,]
.r

A I V sla

lll Postops Lrf der-oo extersive vibration lesiin!l aird af a ys s irer'ore er.rg ir-6ering approval, fLrihei' assu[ance oi Toliable op-.ratlon under a wi|rcl cofd tions.

'/l -

lnsert retractor retaining clamP


and tighten with screwdriver.
5.

lnstall lamp and attach toP refracto r access cove r.

lnstallation is complete.

e o,,ilc eiii-. l,"Lrij:l(r


i-dsitdl'r1r

'rtirt

ijl':ls

Ln-rilr,:'l:r:lorirl-s:

i Posiop serils is corf pleie y J.L. lsied for your saieiy a!rd L iiqtiesi of ,.d i,rilproval by aLl local elecI

does

foi

pay 10 i:rlie crancos. l-io oprane Visia

i-cal

speciois.

ft:;aSrrr

Wit'if:q
rrv

Prer,'r red um ralrcs are equipped wiih hand rroles ior slr-np e i e cl v rin!]. lvlu t pLc itrirteai Um lra L-es

arc supll cd r,vlth

r-.s pre-inserteal in eacl-r artl.

Larnp tsallasl hiorninaI Frirnary Uolta-tie Primary Vo!tage Fange StarliriE Line Ctirrent (amps) Ope!'aiiFg i.in e C'-irreni (ainP9) Primary Drop oLti \lol{age

TAELE oF E.r:CTRIe ;\L aC F-IAIF]/AOTE f1|ti-ll-!Cf,i I /5 !',,:tt H 39 L'].r.!r! l0l r":1t H 38 [,li:'.urv al,r r,. rirf i,,i':rtt..!t.r aLrlo:lab i7e. :i.il ii. t!:i::llr Car.:rlaf i !i,,rl:!!ar 't2X :.1f 2 ii 2l ; 120 2U8 !'il 2ija I 10',, I{t." t.., r l iJ'. lt., lOi. lLr', l0'.
Lcss

Thaf CP'.r.i

r !l

Le::l Ttra r !perrtrng

12
,2
..c 12f;

T:5
2l)

rll
:
r,.

Eallasl Walia!e nnput ltrattage


Seconderr! Open CircLjii Voltaqe

t0

I2U
2.11

l:0

214
O er 9a
1.95

1.8 i2. 2a 2N0 25fl

rn 't25 25 :arlr 25i


t,,

9 1t,1 2a 200 t50


1.9

.8

167 25 2uu
25C

Over 90

[-arij] Crest Far:iti


l-arfi p Lunxen

llegulatiEn

5". :!

10'. !'. ia!l-'

itrlinim

nn

ar,xi:ieni 1lariin0'[ernir,

:tl

-5!"

r l0:"
-21)

,r|

Lselc

SINGLE HEAD LUMINAIRES


WATTAGE 175W
M

([/EFCURY LAMPS ONLY)

PN MARY LINE VOLTAGE

POLE BASE TYPE

LUN4

NA]RE MOUNT!NG HEIGHT (FT NOM)

STANDARD

POLE

PHOTO

FNS
BLACK

CELL'

= 260
261

100w
MEBC

DIBECT

ERC B

ANCHOB BASE

262

rNc

120

204

240

/N10/

/N10/J

10

12

MULTI-HEAD LUMINAIRES
WATTAGE

PRIMAFY LINE VOLTAGE (N4EFOURY LA[/PS ONLY)


NCAN

NUIVBER OF

]]EADS DESIRED

POLE BASE
TYPE DIF EMB ANCH BASE
J

LUMINAIRE MOUNTIN G ]]GI (FI NOM)

STD POLE

POLE FINS

PlloTo

IT il
250 261

175W
N4ERC

100w
MERC

3
'120

3+l
/ N40/

BLA(]K
'12

tNc

208

240

277

/N20/ /N30/

/N31/

/N41/

10

14

WALL BRACKET LUMINAIRES


WATTAGE PR MARY LINE VOLTAGF {MERCUBY LAMPS ONLY)

NUMBER OF ARMS REOU FED

BRACKET ARMS F N SH DES RED

H
260 261 262

175W MERC
B

r00w
MEFC

iNCAN

BLACK
K

tNc

120

20a

240

/w82/

Use the above tables to review exactly what features you wish to specify in your Vista lll lu minaire.

26l

120

/wBz/

This example shows how you would develop such a catalog number.

26/B/2o/waz/<

*Only 120V units are UL ljsted. UL does not recognize photoconirol com ponents othe r than 1 20V.

H o l o p h a n e'

llT i *'i iT i"ltfl

,-i{i
"":,:.''ffi

ti#

i::

n ;,t .n ":"
PRTNTED tN U.S.A.

7268-8M-8/72

Das könnte Ihnen auch gefallen