Sie sind auf Seite 1von 313

IBM System x and BladeCenter

IBM System x and BladeCenter

Jefferson de Almeida Silva Systems Management & Product Specialist CTSS = Channel Technical Sales Specialist Enablement BP Technical
jeffs@br.ibm.com

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Exploso de informaes!
Emails
Instant Messages
2

Mobile

GPS

Opportunities

Communication
Tweets

Smart Meter

Documents

Sensors
Speed
Temperature Velocity

Inventory Movements

Transactions
Service Calls

Sales Orders

Things

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Como a IBM est gerenciando essa exploso...


Automate

Integrate Secure

Smarter Computing Efficient and Innovative IT for Improved Economics

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM Next Generation Platform soluo para um novo mundo

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BOM DIA !! SEJAM BEM VINDOS !!! 5 mins de descontrao....................VAMOS L........ 1) O que STG ? 2) Entendendo Brand, o que X, P, Z, RSS, SS, SSW, SN? 3) Qual a cor do cavalo branco de Napoleo? 4) Qual o conceito de EXA? 5) Qual o configurador de X and BladeCenter? 6) Qual o atual ministro do MCT? 7) Qual empresa lder em registro de patentes?

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x & BladeCenter Agenda:


Histria IBM Certificao de produto IBM System x and BladeCenter Conceitos Design dos Servidores / Nomenclaturas Recursos Portflio de Servidores Opcionais Gerenciamento de hardware integrado In-Band e Out-Of-Band Portflio Subsistema de Discos Subsistema de Discos Interfaces histrico (Controladoras e RAID) BladeCenter Planejar instalaes / Consideraes eltricas BC Suporte a instalaes e Ps-Instalaes BC Virtualizao / Tecnologias Cloud Sistemas de Gerenciamento (ISD) Programa Know Your IBM
6

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Histria da IBM

O portflio de produtos da IBM no incio do sculo: Balanas comerciais, Cortadores de frios, Relgios de ponto, Tabuladoras e perfuradoras de carto

Janeiro, 1920
7

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Histria da IBM
Qual o negcio da IBM ? Uma companhia em constante transformao

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Histria da IBM
Os Credos da IBM Respeito pelo indivduo O melhor atendimento do mundo ao Cliente Busca da excelncia

Dedicao ao sucesso de cada cliente

Valores IBM

Inovao que faz a diferena para nossa empresa e para o mundo Confiana e responsabilidade pessoal em todos os relacionamentos

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Liderana em nmero de patentes

Pelo 19 ano consecutivo, IBM lder em nmero de patentes com 6.180

http://ificlaims.com/index.php?page=misc_Top_50_2011

National Medal of Technology & Innovation

10

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Microsoft Xbox 360

Sony Playstation 3

Nintendo Wii

PowerPC

Cell BE

PowerPC

For more information see ibm.com/chips


11

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Tela do site: Certificaes IBM System x and BladeCenter

http://www-03.ibm.com/certify/certs/xs_index.shtml
12

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Informaes dos Testes:


IBM Certified Specialist System x Technical Fundamentals V10 (000-152)

Nmero de Questes

Tempo

Pontuao Mnima

Portugus / Ingls

42

75 min

Vriavel

Sim /Sim

IBM Certified Systems Expert System x Thecnical V6 (000-087)

Nmero de Questes

Tempo

Pontuao Mnima

Portugus / Ingls

40

75 min

Vriavel

Sim /Sim

13

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Pr-requisitos para obteno da certificao 000-152


IBM Certified Specialist System x Technical Principles V10 (000-152) 6 a 12 meses de experincia prtica em dimensionamento de solues System x; Conhecimento sobre os Sistemas Operacionais: - MS Windows Server, Linux e Vmware; Conhecimento dos sistemas de gerenciamento, conceitos bsicos de rede, conectividade NAS, SAN, iSCSI, Ethernet (Incluindo camada OSI) e sobre as Arquiteturas IBM System x (XArchitecture) e BladeCenter; Realizar os treinamentos disponibilizados no PartnerWorld.

14

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Pr-requisitos para obteno da certificao 000-087


IBM Certified System Expert System x V6 (000-087) 12 meses de experincia em solues IBM BladeCenter; Conhecimento sobre os Sistemas Operacionais: - MS Windows, Linux e Vmware; Conhecimento em estratgias para deploy de OS; Conhecimento em conectividade para Redes/SAN; Conhecimento sobre os Mdulos de Conectividade (I/O Modules) para IBM BladeCenter; Experincia em IBM Systems Director; Experincia em solues para DATACENTERs, Design e Planejamento de capacidade; Realizar os treinamentos disponibilizados no PartnerWorld.

15

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Guia passo a passo como se preparar pelo PW

16

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Famlia de Sistemas IBM Possibilita a melhor escolha e inovao

System z

System p

System Storage

System x
17

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

X - Architecture Filosofia do Design A fora da IBM em x86


Industry Standard Technologies

Ease of Use

System x

System p

System z

System Storage

BladeCenter

Efficiency Availability Reliability Scalability Virtualization

18

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Liderana IBM para um mercado em constante evoluo com x1, x2, x3..
5th Gen: Breakthrough performance, ultimate flexibility, simpler management 4th Gen: First x86 server to break 1 Million tpmC 3rd Gen: First x86 server with Hot-swap memory 2nd Gen: First x86 server with 100 #1 Benchmarks 1st Gen: First x86 server with scalable 16 processor design
2003 2nd Generation 2001 1st Generation 2005 3rd Generation 2007 4th Generation

2010 5th Generation

19

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

X-Architecture, a cada ano mais inovaes........

20

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

X - Architecture Filosofia do Design

Performance Adaptativa

Infraestrutura Integrada

Totalmente Modular

Eficincia em Energia e Arrefecimento


21
21

Gerenciamento Pr-ativo
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Nomenclatura
Full Name = IBM System x#### Short Name = x####

IBM System x3950 XX

22

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Tendncias da Plataforma
Migraes de infra-estrutura em ambientes de alta densidade / HPC

Requisitos de performance e otimizao de espao crescentes

Blades

Rack Optimized

Towers

Eficincia operacional e otimizao de base. Consolidao de Servidores

Large SMP
23

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Projetando Soluo System x and BladeCenter Scale Up or Scale Out ?

Estratgias, Ferramentas e Suporte Ajudando Clientes a tomarem decises certas Tendncias


24

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x Enterprise

Server Consolidation, Virtualization

System x iDataPlex
Scale Out

Scale Up

Web 2.0, HPC, Grid

Infrastructure Simplification, Application Serving

BladeCenter

Single Applications
Definitions Scale out - more servers sharing the workload Scale up - single machine with more processors, more memory, more I/O

System x Rack and Tower


25

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Portflio constantemente inovado com extensa linha de produtos


Large symmetrical multiprocessing (SMP) Intelligent Cluster

iDataPlex

Clusters, HPC, Virtualization, Web 2.0 & Cloud

Enterprise Class
Scale up / SMP computing
x3850 X5 x3690 X5 x3755 M3 x3650 M3 dx360 M3

Flagship Class
x3550 M3 x3400 M3 x3500 M3 x3630 M3 x3620 M3 x3200 M3 x3100 M3
Single Socket

BladeCenter S, E, H, T, HT

HX5
HS12/22/22V LS22/42 JS12//22/23/43 QS21/22
High density
2012 IBM Corporation

x3250 M3 HS12 Dual Socket

HS22 HS22V Multi Socket

Scale out / distributed computing


26

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Projetando Solues System x and BladeCenter System x Solution Configuration Tools

Servidores para Gerenciamento financeiro (ERP), Processamento de transaes on-line (OLTP), Processamento analtico (OLAP), ambientes financeiros e de negcios e de infra-estrutura de IT.

27

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Comunicao tudo

28

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Ferramentas de Suporte s Configuraes

http://www.xseries.org/
29

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Ferramentas de Suporte s Configuraes


COG :Arquivo em PDF ou Web site para consulta e configurao de opcionais xREF: PDF para rpida referncia sobre todos os aspectos de hardware dos servidores (chipset, vdeo, memria, modelo de cpu, etc...) IBM Power Configurator / Power Calculator: Calcula o consumo total de energia (MW/h) e dissipao trmica (BTUs) de todos os equipamento de uma soluo IBM IBM Sizing Guides: Ferramenta de Dimensionamento (sizing) de solues com servidores e Storage IBM (Ex: Oracle, SQL, Citrix, SAP, File Server, etc...) IBM ServerGuide: auxilia na instalao do SO nos servidores, colocando automaticamente todos os drivers necessrios. Atualizao automtica dos drivers durante a instalao, caso o servidor esteja conectado internet IBM SSCT : Configurador oficial IBM para System x and BladeCenter. BCIG : Guia de interoperabilidade BladeCenter X-Config Nova gerao, ferramenta para configurao
30

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Configuration and Options Guide COG

31 31

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

ServerProven

32 32

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

xREF

33 33

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

xREF

34 34

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x & BladeCenter Power Configurator

35 35

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x & BladeCenter Power Configurator

36 36

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x & BladeCenter Power Configurator

37 37

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter Interoperability Guide

38 38

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BCIG

39

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BCIGMX I/O

40

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x DDR3 Memory Configurator

41 41

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x DDR3 Memory Configurator

42 42

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x DDR3 Memory Configurator

43 43

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x DDR3 Memory Configurator

44 44

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x & BladeCenter Competitive Sales Tool

45

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x & BladeCenter Competitive Sales Tool

46

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RedBooks Literatura digital

- Coleo de documentos em PDF para aprofundamento sobre tecnologias - Guias de instalao de Servidores - Guias de Manuteno - Gerenciamento dos sistemas - Arquivos disponibilizados pelo site da IBM

http://www.redbooks.ibm.com/

47

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Standalone Solutions Configuration Tool SSCT

48 48

15 June 2012 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Ferramentas de Suporte s Configuraes

49

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Portflio: Recomendado por segmentao de produto


Smaller businesses Smaller remote environments Stand-alone requirements

Tower

Blades

Large consolidation environments Server & infrastructure replacement BCS remote environment consol Small to Mid-range businesses Segmented workloads Existing fit for purpose

System x

Rack

eX5

Heavy vertical workloads Large virtualization projects Legacy system replacement HPC / Analytic workloads WEB2.0 environments Massive scaling

Specialty

50

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Portflio em escala: Scale Up x Scale Out


NEW 2-SOCKET STORAGE OFFERING

Towers
Scale Up / SMP Computing

Racks

x3650 M3

x3630 M3

x3620M3 x3500 M3 x3400 M3 x3200 M3 x3550 M3 x3250 M3

x3100 M3 Scale Out / Distributed Computing


51

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


Rack Systems Tower Systems

Xeon 5600 series System x3650 M3 2U Two Socket Xeon 5600 series System x3500 M3 Two Socket

5U Rack Mount via Configure to Order (CTO) or Option Kit

System x3630 M3 2U Two Socket

Xeon 5600 series Xeon 5600 series System x3400 M3 Two Socket
5U Rack Mount via Configure to Order (CTO) or Option Kit

System x3620 M3 2U Two Socket

Xeon 5600 series

System x3550 M3 1U Two Socket

Xeon 5600 series

Xeon 3400 series

System x3200 M3 Single Socket System x3250 M4 52Single Socket 1U


This document is for IBM and IBM Business Partner use only

5U Rack Mount via Configure to Order (CTO) or Option Kit


2012 IBM Corporation

IBM System x and BladeCenter Novo processador Intel Xeon 34XX (mais performance) At 32GB RDIMM e 24GB UDIMM / 6 DIMMs (8GB DDR2 x3200 M2) Fonte redundante em alguns modelos At 4TB de armazenamento interno Novo IMM, uEFI, Director (Call Home) Suporta criptografia nativa

x3200 M3

Novo processador Intel Xeon 56XX Quad Core (At 40% mais performance) Fonte redundante em alguns modelos Cadeado para proteo dos dados At 8 TB armazenamento interno At 128GB Memria 5 x PCIe I/O x3400 M3 Novo processador Intel Xeon 56XX Quad e Six Core (At 40% mais performance) Fonte redundante Cadeado para proteo dos dados At 12 TB armazenamento interno 6 x PCIe I/O x3500 M3
53

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


x3550 M2 Servidor Torre IBM System x3200 M3 Speed Bump Refresh Business 1- 1x processador Intel Xeon Quad Core 2U, 2-socket 2-socketRaid 0,1 integrada (+ performance) 2-Critical Controladora de 2U, discos Intel Westmere Intel Xeon QC Processor 3- Discos Hot-Swap 250GB 3.5 (+confiabilidade) x3550 M3 x3250 M2 4- Memria padro 2GB DDR3 / suporta at 16GB UDIMM e 32GB RDIMM Speed Bump Refresh General 5Software de gerenciamento gratuito IBM Systems Director 1U, 2-socket Business 1U, 2-socket 6Modelos com Fonte redundante Intel Westmere Intel Xeon QC Processor 7- 3 anos de garantia on site x3500 M3 x3500 M2 x3550 M3

pequenas e mdias empresas carga de trabalho e-mail, Web, 5U, 2-socket Intel Westmere servidor de arquivo 5U, e 2-socket impresso Intel Xeon QC
Processor

Business Pblico-alvo: Critical

Refresh

Speed Bump

x3400 M2

x3400 M3

Benefcios: baixo custoRefresh de aquisio para rodar aplicativos do negcio com Speed Bump General segurana de gerenciamento Business e confiabilidade. Alm de incluir ferramentas5U, 2-socket 5U, 2-socket Intel Westmere poderosas. Intel Xeon QC
Processor

54

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Servidor Torre IBM System x3200 M3


Modelos com fonte redundante

55

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


x3550 M2 x3550 M3

Speed Bump Servidor Torre IBM System Refresh x3400 M3 Business 1- Critical At 2x processador Intel Xeon 5500 ou 5600 2U, 2-socket 2U, 2-socket Intel Westmere 2- Controladora de discos Raid 0,1 integrada (+ performance) Intel Xeon QC Processor 3- Discos Hot-Swap 4x 3.5 ou 8x 2.5 6Gbs x3550 M3 x3250 M2 Speed Bump 4- Memria padro 2GB DDR3 ou 4GB DDR3 / suporta at 128GB Refresh General 5Opo de fonte de energia redundante e no redundante 1U, 2-socket Business 1U, 2-socket Intel Westmere 6- 3 anos de garantia on site Intel Xeon QC Processor 7- SW de gerenciamento e anlise de falhas x3500 M3 x3500 M2

Business Pblico-alvo: Critical

Refresh

Speed Bump

Indstrias com base em filiais e outras SMBs com ambientes 5U, 2-socket 5U, 2-socket Intel Westmere Intel Xeon QC corporativos distribudos usando cargas de trabalho de e-mail, Processor arquivo e impresso e colaborao (ex: virtualizao, ERP, CRM)

Benefcios: Flexibilidade de crescimento e baixo custo de aquisio para rodar aplicativos do negcio com segurana e confiabilidade.

56

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


x3550 M2 Servidor Rack IBM System x3250 M3 Speed Bump Refresh Business 1- 1x processador Intel Xeon Quad Core 2U, 2-socket Critical 2-socket Raid 0,1 integrada 2Controladora de2U, discos Intel Westmere Intel Xeon QC Processor 3- Discos Hot-Swap SAS 2.5 (+performance e confiabilidade) x3550 M3 M2 4- Memria x3250 padro 2GB DDR3 / suporta at 16GB UDIMM e 32GB RDIMM Speed Bump Refresh General 5Software de gerenciamento gratuito IBM Systems Director 1U, 2-socket Business 1U, 2-socket 6- Anlise preditiva de falhas Intel Westmere Intel Xeon QC Processor 7- 3 anos de garantia on site x3500 M3 x3500 M2 x3550 M3

Business Pblico-alvo: Critical

SMBs e grandes empresas executando cargas de trabalho 5U, 2-socket 5U, 2-socket Intel Westmere como e-mail, servidor Web, arquivo e impresso, firewall, segurana e Intel Xeon QC Processor aplicativos personalizados x3400 M2 x3400 M3
General Benefcios: Business
Refresh Speed Bump

Refresh

Speed Bump

Primeira escolha para clientes sensveis a preo pois entrega 5U, 2-socket 5U, 2-socket Intel Westmere desempenho, gerenciamento em um servidor rack compacto de 1U. Intel Xeon QC
Processor

57

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x3250 M4 overview


IBM x3250 M4 Processors #Socket Form factor Max Memory HDD bays Disk drive capability RAID PCI-express x16/x8/x4/x1 Power Bromolow Xeon & Ci3, Pentium , Celeron 1 (Intel C202 Chipset) 1U rack, 22 deep 32GB 4 UDIMM ECC optional SATA, PCIe RAID 2x3.5 SATA or 4x2.5 SAS SS SATA ; SS/HS SAS Standard ServeRAID C100 0/1; HW RAID 0/1/5 upgradable 0/1/1 ( dedicated for w RAID 0,1) /3Q 1.300W fixed, 80 + Bonze 2. 460W Redundant, 80+ silver (2 Mechanical bases) Dual gigabit/Yes
This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

Ethernet/TP M Managemen t

58

Warranty

IBM System x and BladeCenter

Novo processador Intel Xeon 56XX (mais performance) Consolidao 20:1 At 144GB RDIMM (18 DIMMs) Fonte redundante At 4.TB de armazenamento interno 6Gb Raid Suporta criptografia nativa

x3550 M3

Novo processador Intel Xeon 56XX (mais performance) Liderana em SpecPower Benchmark At 144GB RDIMM (18 DIMMs) Fonte redundante At 8TB de armazenamento interno 6Gb Raid Suporta criptografia nativa x3650 M3
59

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


x3550 M2 Servidor Rack IBM System x3550 M3 Speed Bump Refresh Business 1At 2x processador Intel Xeon Quad Core 2U, 2-socket 2-socketRaid 0,1 ou Raid 0,1 e 5 integrada 2-Critical Controladora de 2U, discos Intel Westmere Intel Xeon QC Processor 3- Discos Hot-Swap SAS/SATA 8x 2.5 (+performance e confiabilidade) x3550 M3 x3250 M2 4- Memria padro 2GB DDR3 ou 4GB DDR3 / suporta at 144GB Speed Bump Refresh General 5- Software de gerenciamento gratuito IBM Systems Director e PFA 1U, 2-socket Business 1U, 2-socket 63 anos de garantia on site Intel Westmere Intel Xeon QC Processor 7- Modelos com 2x fontes integradas x3500 M3 x3500 M2 x3550 M3

suporta aplicativos colaborao, virtualizao, consolidao e 5U, 2-socket 5U, 2-socket Intel Westmere aplicativos front-end (i.e. SAP e Oracle) Intel Xeon QC
Processor

Business Pblico-alvo: Critical

Refresh

Speed Bump

x3400 M2

x3400 M3

Benefcios: clientes que precisam de uma soluo de eficincia Speed energtica, Bump Refresh General alta disponibilidade, flexvel para crescimentos e com capacidade de Business 5U, 2-socket 5U, 2-socket Intel Westmere virtualizao que pode ser facilmente gerenciada Intel Xeon QC
Processor

60

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


Predictive Failure Analysis (PFA) Hard disk, power supplies, memory, processors, voltage regulator modules, and cooling fans (with IBM Virtual Media Key) High Availability Hot-swap & redundant disk, power, and cooling Redundant Ethernet Error Checking & Correcting (ECC) memory, Chipkill, memory mirroring

Front of Light Path Diagnostics Panel

1U

Up to eight 2.5 SAS, SATA, or solid state hot-swap hard drives with PFA Two USB Ports Video Port Light Path Diagnostics Panel

IBM System x3550 M3


61

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System x3550 M3

Slot 1: PCI Express x16 half length, low profile

Optional conversion options to PCI-X

Slot 2: PCI Express x16, half length, full height

1U

Ethernet port for Integrated Management Module (IMM) Optional IBM Virtual Media Key enhances functionality

Two optional redundant Ethernet ports

Two redundant Ethernet ports

Video Port

LED Panel including locator

Serial Port

Two USB Ports

Up to two hot-swap power supplies with PFA (675W, 92% efficient)

62

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


USB hypervisor connector IBM ServeRAID controller or optional upgrades

IBM System x3550 M3


Up to two hotswap power supplies with PFA (675W, 92% efficient)

IBM Integrated Management Module (IMM) Calibrated Vectored Cooling

IBM Virtual Media Key connector

Two redundant Ethernet ports

Two optional redundant Ethernet ports (via daughter card)

Six altimeter controlled hot-swap redundant cooling fans with PFA


63

Two Intel processor sockets with PFA

Eighteen ECC DDR3 SDRAM sockets with PFA (Chipkill, memory mirroring)
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter


x3550 M2 Servidor Rack IBM System x3650 M3 Speed Bump Refresh Business 1At 2x processador Intel Xeon Quad Core 2U, 2-socket 2-socketRaid 0,1 ou Raid 0,1 e 5 integrada 2-Critical Controladora de 2U, discos Intel Westmere Intel Xeon QC 3- Discos Hot-Swap SAS/SATA 16x 2.5 (+performance Processor e confiabilidade) x3550 M3 x3250 M2 4- Memria padro 4GB DDR3 / suporta at 192GB Speed Bump Refresh General 5- Software de gerenciamento gratuito IBM Systems Director e PFA 1U, 2-socket Business 1U, 2-socket 63 anos de garantia on site / suportam 2x fontes de energia Intel Westmere Intel Xeon QC Processor 8- Excelente I/O: 4x portas PCI e at 4x portas de Rede x3500 M3 x3500 M2 x3550 M3

suporta aplicativos colaborao, virtualizao, consolidao, 5U, 2-socket 5U, 2-socket Intel aplicativos front-end (i.e. SAP e Oracle), banco de dados eWestmere HPC Intel Xeon QC
Processor

Business Pblico-alvo: Critical

Refresh

Speed Bump

x3400 M2

x3400 M3

Benefcios: clientes que precisam de uma soluo para ambientes crticos Speed Bump Refresh General sem ponto de falha com alta eficincia energtica, disponibilidade, flexvel e Business 5U, 2-socket 5U, 2-socket Intel gerenciada Westmere com capacidade deIntel virtualizao que pode ser facilmente Xeon QC
Processor

64

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System x3650 M3


Pop-Out/DropDown Light Path Diagnostics Panel Video Port USB 2.0 Ports Hexagonal Ventilation Holes

Empty Hot-Swap 2.5 HDD Bays

Hot-Swap 2.5 HDDs

Empty HDD Fillers

Status Lights

Optical Drive Bay Light Path Diagnostics Panel Eject Button


2012 IBM Corporation

Power Button

65

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Servidor Rack IBM System x3650 M3


Servidores flexiveis para a revenda escalar de acordo com a necessidade do cliente

66

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System x3650 M3

Adapter Slots

Adapter Slots

Fast Ethernet Port for IMM Optional Gbps Ethernet Ports

Video Port Serial Port

USB Ports

Hot-Swap Power Supplies

Standard Gbps Ethernet Ports


67

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System x3650 M3


USB Hypervisor Key

ServeRAID Controller Hot-Swap HDD Bays

Hot-Swap Power Supplies

Processor Socket

Adapter Slots Gbps Ethernet

Hot-Swap Fan Packs

18 DIMM Slots

Processor / Heat Sink

Adapter Slots

68

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Oportunidades no mercado x86


Grande oportunidade em servidores Rack & Torre
-61% da renda x86 (78% das unidades) Liderana tecnolgica nos principais desafios dos ambientes de TI

$24.3B

Energia & Resfriamento

23% Hi Vol Hi End Blades


Blades $5.6B

Hi End 16% $3.8B

Hi Volume $14.8B 61%

Virtualizao & Utilizao


Workload
-1 & 2 socket systems ideais para Infraestrutura, Colaborao e Web -60% do total das oportunidades de servidores -High volume maior utilizao nestes 3 workloads

Gerenciamento

Virtualizao
-Maior parte das licenas de VMWare esto em Servidores High Volume
69

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Arquitetura com Chipset padro Intel

70

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Intel Xeon Dual-Core System Design

Dual Socket with Dual Core in each socket

L2 Cache

L2 Cache

L2 Cache

L2 Cache

Front Side Bus

PCI-E Bridge

Memory Controller

I/O Hub

USB PCI

FBD Fully-Buffered DIMM Memory

71

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

AMD Opteron Dual Core System Design

L2 Cache

L2 Cache

L2 Cache

L2 Cache

DDR2 Memory

Crossbar MEM HT CTRL

Crossbar MEM HT CTRL

Integrated Memory Controllers per Socket

Hypertransport

HT HyperTransport Technology

PCI-E Bridge

PCI-E Bridge

I/O Hub
72

USB PCI
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

A evoluo INTEL no Chipset !

Arquitetura dos novos Processadores / servidores


2004-2006
Nehalem

2007-2008
Nehalem

2009

Nehalem

I/O Hub

MCH

MCH

PCI Express* Gen 1, 2

DMI ICH

I/O

I/O

73

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Evoluo com a famlia Intel Xeon Srie 5xxx

NEW!
Nova Arquitetura de Processador Nova Arquitetura de Plataforma Novo Subsistema de Memria Novo Subsistema de I/O Novas Opes (SSD e 10GbE)

NEW!

Intel 5520 Chipset

Intel Data Center Manager NEW! PCI Express* 2.0

Intel Node Manager

NEW!
Intel X25-E SSDs ICH 9/10 Intel 82599 10GbE Controller

Desempenho Inteligente
74

Eficincia em Energia Automatizada


This document is for IBM and IBM Business Partner use only

Virtualizao Flexvel
2012 IBM Corporation

IBM System x and BladeCenter

Intel Xeon Processor 5500 Series Especificao de Produto


CPU Number
95W

Usage

Cores

Cache

Link Speed

Max Mem Speed

Turbo

HT

X5570 (2.93 GHz) X5560 (2.80 GHz) X5550 (2.66 GHz)


80W

Advanced Standard
60W

8M

6.4
GT/s

1333
MHz

+3

E5540 (2.53 GHz) E5530 (2.40 GHz)


80W

8M

5.86
GT/s

1066
MHz

+2

E5520 (2.26 GHz) L5520 L5506 E5506 (2.13 GHz)


80W

Low Power Basic


2-4 4M 4.8
GT/s

E5504 (2.00 GHz) E5502 (1.86 GHz)


Dual Core

800
MHz

No No HT Turbo

75

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

76

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Intel Xeon Processor 5600 series based Server platforms Memory bandwidth Intel Westmere-EP
1333 MHz memory
CPU

CPUs X5650 X5690 L5640

10.6 GB/s 10.6 10.6

CPU

Advanced

Performance Memory Configuration 1066 MHz memory


CPU CPU

8.5 GB/s 8.5 8.5

Standard

E5620 - E5647 L5609 - L5630

Balanced Memory Configuration


6.4 GB/s 6.4 6.4

800 MHz memory


CPU CPU

Basic

E5603 E5607

Rich Memory Configuration

77

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

78

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Relao de performance entre Nehalen e Westmere


Performance dos novos processadores Westmere Nehalem Processors
Xeon Xeon Xeon Xeon Xeon Xeon Xeon Xeon Xeon Xeon Xeon E5506 E5507 E5620 E5630 E5640 X5650(6c- X5660(6c X5670(6cX5680(6c X5667(4c X5677 (2.13/4.8) (2.26/4.8) (2.4/5.8) (2.53/5.8) (2.66/5.8) 2.66) -2.8) -2.93) -3.33) 3.06) (4c 3.46)

Performance dos processadores Nehalen

Xeon E5504 (2.00/4.8) Xeon E5506 (2.13/4.8) Xeon E5520 (2.26/5.86) Xeon E5530 (2.4/5.86) Xeon E5540 (2.53/5.86) Xeon X5550 (2.66/6.4) Xeon X5560 (2.8/6.4) Xeon X5570 (2.93/6.4)

1% 0% -27% -29% -32% -39% -41% -42%

7% 2% -23% -26% -28% -36% -38% -39%

56% 50% 13% 9% 5% -6% -9% -11%

61% 56% 17% 12% 8% -3% -6% -11%

67% 60% 21% 16% 12% 1% -2% -5%

134% 124% 69% 63% 57% 41% 37% 33%

141% 131% 74% 68% 62% 46% 41% 38%

147% 137% 79% 72% 66% 49% 45% 41%

161% 150% 88% 81% 75% 57% 52% 49%

90% 82% 37% 32% 28% 15% 11% 8%

112% 103% 53% 47% 42% 28% 24% 21%

79

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

80

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

81

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Facilidade de gerenciamento e alta disponibilidade


Anlise de falhas em 6 componentes Processador
Ventiladores VRM Proc Memria

HDs

Memria Disco rgido Ventiladores

VRM Proc Fontes

Fonte de energia VRMs

Abertura de chamados automtica

IMM (Integrated Management Module)


82

Altssima disponibilidade
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter


Front of Light Path Diagnostics Panel
Amber light indicates there is a problem with the server

Light Path Diagnostics Component Level Lights


Indicates what individual component has PFA alert or has failed

Pop-Out Light Path Diagnostics Panel


Indicates what subsystem has problem

83

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


Component

Hard Drive

What is Predictive Failure Analysis (PFA)? Component analysis logic that can predict an impending failure based on data from the component Typically notification is within 24 to 48 hours of a potential failure Benefits Less unscheduled downtime Better overall availability of the servers Components can be replaced under warranty prior to a failure

Memory

Processor

VRM

Cooling Fan

Power Supply

84

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

O que Call Home?


Call Home um funcionalidade que permite a abertura de chamados tcnicos pelo prprio servidor, sem a necessidade de interveno humana Os servidores IBM System x dispem do recurso Anlise Preditiva de Falha (PFA), que capaz de prever falhas, com at 48 horas de antecedncia, para os seguintes componentes: - Processadores - Pentes de memria - Discos rgidos - Fontes de alimentao - Ventiladores - VRMs O software IBM Systems Director, gratuito para servidores IBM, pode ser configurado para alertar os administradores de rede, via alarme ou e-mail por exemplo, sobre eventuais problemas. Clientes que compraram Service Pac de manuteno podero registrar seus servidores, instalar o IBM Director e utilizar o servio de Call Home.
85

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Por que incentivar o Call Home? Diferenciao: A concorrncia no tem!! Servidores da concorrncia monitoram no mximo 3 componentes com PFA (memrias, discos e processadores). Se a monitorao pr-falha deficiente, no conseguem oferecer o servio. Reduo de custos: Clientes podem reduzir custos ao gerenciar seus servidores com o IBM Director e automatizar a abertura de chamados. Disponibilidade: Servidores melhor gerenciados e que podem abrir chamados tcnicos trazem maior disponibilidade para aplicaes crticas como Bancos de Dados, ERPs ou Virtualizao. Fidelizao: Menores custos e maior disponibilidade so caractersticas valorizadas pelos clientes! Alm de possibilitar vendas de servios adicionais como instalao do IBM Director.

86

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System x Enterprise Servers


60 50 40 30 20 10 0 IBM HP Dell

4-socket Intel Server Market Share


70 60 50 40

Uma Seleo nica de servidores enterprise corporativos de alta performance, proporcionando, disponibilidade, escalabilidade e confiabilidade.
87

30 20 10 0 IBM HP Dell

+8-socket Intel Server Market Share


Source: IDC Tracker

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM inovao Levando valor aos clientes por meio da tecnologia


Proporciona: Investimento de mais de $800M Subsistema de memria aprimorado nos ltimos 10 anos em XGerenciamento proativo Architecture Recursos e funes de confiabilidade aprimorada Escalabilidade lder de mercado Design otimizado para alta performance

88

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM Systems Investimento em Tecnologia System x


Virtualized hosted client BladeCenter integration Xtended Design Architecture Cell Broadband EngineTMbased blade

Blade.org

2001

2002

2003

2004

2005 2006/7/8/9 2010/11/12

X-Architecture

X3 Open Enterprise BladeCenter H Systems management X-Architecture BladeCenter Architecture specification scalability

89

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Tecnologia X-Architecture, System x, Revolucionando o mercado x86!


Hurricane 4 Way Performance balanceada!
Processor Interface Quad 1066 FSB - 16GB/s

2.6x increase over Hurricane 3.0


Snoop filter ~2x as large as X3s

Snoop Filter for Quad FSB coherency tracking Memory 8 Advanced Buffer eXecution chip EI3 2.5 GT/s channels IB: 2 x12 34GB/s Read, 17GB/s Write DDR2/3-533, 1GB, 2GB, 4GB & 8GB DIMMs X4 Chipkill w/ HPMA, Memory mirroring, Hot South Bridge ESI Add/Replace
I/F

IA32 Proc

IA32 Proc 1066 MT/s

IA32 Proc

IA32 Proc

SP: 3 x8

Hurricane 4 266 MHz

5.12 GT/s

Direct connect I/O 2 x12 IB Ports 12GB/s Connects to Calgary (PCIX) and Calioc2 (PCIE) ESI support for ICH-8 South Bridge Scalability 3 Scalability Ports 30GB/s Up to 16 sockets

Flash I/F

LPC

2.1 GT/s
Nova x4 Nova x4 Memory DIMMS Nova x4 Nova x4 Nova x4 Nova x4 Nova x4 Nova x4

533 MT/s Scalable Virtual L4 cache

90

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Os diferenciais do Chipset IBM !

IBMs Enterprise X-Architecture


5th Generation 2010

Maximum Performance, Reliability, and Scalability


x3850 X5 / x3950 X5

4th Generation 2008/2009


Introduced First x86 Platform to Break 1 Million tpmC
x3850 M2 / x3950 M2

3rd Generation 2005


Introduced Hot-Swappable Memory for Maximum Reliability
x460/x3950 HX5

2nd Generation 2003


Introduced Snoop Filter to Achieve 100 #1 Benchmarks
x445 x3690 X5

1st Generation 2001


Introduced First Scalable 16 Socket x86 Platform
x440
91

MAX5
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

eX5

5a gerao do portfolio IBM lder em tecnologia


para servidores x86 empresariais Expanso da X-Architecture para o IBM

BladeCenter e Mq de 2Us 2X a cap. de memria dos concorrentes


resultando em at 2/3 dos custos com software

Menores custos de aquisio e


implementao para solues x86 Enterprise

#1 em marketshare de servidores x86 escalveis


92

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


System x 3850 X5 System x 3690 X5

System x System x BladeCenter HX5

System x MAX5

System x

System x

93 93

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

A nova forma de pensar da IBM Introduzindo o Portfolio eX5

System x3850 X5

IBM BladeCenter HX5 BladeCenter HX5

System x3690 X5

MAX5
Maxima escalabilidade de memria independente dos processadores

eXFlash
IOPs com storage SSD

FlexNode
Provisionamento programado

Um Sistema de 4 soquetes

Dois Sistemas de 2 soquetes

94

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBMs Enterprise X-Architecture

De 2001 a 2004 x440, x360 x445, x365

De 2005 a 2006 x460, x366 x3950, x3850

De 2007 a 2010 x3950 M2 x3850 M2


95

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM FireHawk 5 gerao

EXA

Chip #1

EXA 4 Chip EXA 3 Chip


Scalability Port to Additional Processors

Scalability Port to Additional Processors EXA Chip# 2 EXA Chip #3 Scalability Port to Additional Processors

2009

IBM x86 Silicon Investment Evolution

Fire Hawk Chip

2010
96

Scalability Port to Additional Processors This document is for IBM and IBM Business Partner use only and Memory

2012 IBM Corporation

IBM System x and BladeCenter

97

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

x3850 X5 with native QPI scaling


MB1MB1 MB1MB1 MB1MB1 MB1MB1

Intel Xeon Intel

Intel Xeon Intel Boxboro

PCI-E

PCI-E

Boxboro Intel Xeon Intel Xeon

Connects directly via QPI bus

MB1MB1 MB MB1 1

MB1MB MB1MB1 1

QPI Cables
MB1MB1 MB MB1 1 MB1MB MB1MB1 1

Intel Xeon

Intel Xeon Intel

PCI-E

Intel Boxboro Intel Xeon


MB1MB1 MB1MB1

PCI-E

Intel Xeon
MB1MB1 MB1MB1

Boxboro

98

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

8-socket x3850 X5 with MAX5 using QPI and EXA

Connects directly to each CPU via QPI bus 6.4 GT/s

Connects via EXA

99

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

x3850 X5 Resumo

Memory Expansion and Scaling with MAX5 via QPI and EXA

Native Scaling via QPI

Memory Expansion with MAX5 via QPI

Base System

100

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Xeon 8-socket interconnect block diagram

3 2 2

1
0 0

3
3 2

QPI

3
3 2

1
0 0

4
3

4
3

QPI
Cable cross connects CPUs 2 and 3 Cable Links for QPI bus Four QPI cables

101

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

X3850 X5 - 8-socket QPI scaling

REAR VIEW OF CHASSIS

x3850 #1

QPI 1-2

QPI 3-4

x3850 #2

QPI 1-2

QPI 3-4

102

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

MAX5: Memory Access for eX5


Greater productivity and utilization through memory expansion and flexibility

Take your system to the MAX with MAX5 MAX memory capacity An additional 32 DIMM slots for x3850 X5 and x3690 X5 An additional 24 DIMM slots for HX5 MAX virtual density - Increase the size and number of VMs MAX flexibility - Expand memory capacity, scale servers, or both MAX productivity - Increase server utilization and performance MAX license optimization - Get more done with fewer systems
103

1U Rack Mechanical Chassis Top view

Firehawk memory and node controller

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

MAX5 for x3690 X5 and x3850 X5

Lightpath Diagnostics Hot swap fans 32 Memory DIMMs System removes from chassis for easy access

QPI Ports

Firehawk Chipset

EXA Ports

104

QPI attaches to systems Memory BuffersThis document is for IBM and IBM EXA Scalability to other memory drawers Business Partner use only 2012 IBM Corporation

IBM System x and BladeCenter

MAX5 para HX5!


MAX5 HX5

6x memory buffers FireHawk 6 SMI lanes 4 QPI ports 3 scalability ports 24x VLP DDR3 memory

HX5+MAX5 Configurations 2S, 40D, 8 I/O ports, 60m 4S, 80D, 16 I/O ports, 120mm
105

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

MAX5 para mquinas rack!


MAX5 Features Firehawk memory controller 32 DIMMs 1U form factor Connects to systems via QPI

4U x3850 X5

Nehalem

Nehalem

2U x3690 X5 QPI
Boxboro Nehalem Nehalem

QPI
Boxboro Nehalem Nehalem

QPI
Boxboro

PCI-E QPI QPI

PCI-E QPI

PCI-E

Connects directly to each CPU via QPI bus 6.4 GT/s MAX5 1U

MAX5 1U

EXA Scaling
2 1

MB1
4 3

MB2
7 8 5 6

SMI Link to EXA5 Memory Expander/Buffer DDR3 Memory DIMMs

EXA Scaling

106

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System x3690 X5


O primeiro servidor high-end de 2U do mercado: mxima memria e performance
Com apenas 2U, este servidor oferece at 4x a capacidade de memria de seus concorrentes com o dobro de processadores.

Maximiza a memria
33% mais ncleos de processamento e 5x mais capacidade de memria, para 1.7x mais transaes por minuto e 2x mais mquinas virtuais que outros servidores x86 com processadores Xeon 5500 Expanso de memria MAX5 para 46% mais mquinas virtuais e liderana absoluta em performance de banco de dados

Especificaes da mquina 2x Intel Xeon E7 CPUs 32 DDR3 DIMMs, up to 64 with MAX5 2 x8 PCIe slots, 2 x8 Low Profile slots Up to 16x 2.5 HDDs or 24x 1.8 SSDs RAID 0/1 Std, Opt RAID 5 2x 1GB Ethernet Optional 2x 10GB SFP+ Virtual Fabric / FCoEE Internal USB for embedded hypervisor IMM, uEFI, and IBM Systems Director

Minimiza os custos
Alcana a capacidade de memria equivalente a um servidor de 4 soquetes com apenas 2. Economiza suas licenas de software eXFlash 720k internal IOPs for 40x local database performance and $2M savings in equal IOPs storage

Simplifica a gerncia
UEFI / IMM proporcionam o estado da arte em gerenciamento e escalabilidade
107

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Elimine o gargalo de memria e tire o mximo do seu investimento em virtualizao

82%
mais VMs

Mesmo custo de licenciamento para 2 procs

50%
Custo de licenas

Mesmo nmero de VMs

x3690 X5 com MAX5

x3690 X5 com MAX5

Dell R810

Dell R910

Memrias entram em restrio antes que os processadores sejam completamente utilizados.


108

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

x3850 X5: 4-socket 4U x86 (Nehalem EX)


(2x) 1975W Rear Access Hot Swap, Redundant P/S (8x) Memory Cards for 64 DIMMs 8 1066MHz DDR3 DIMMs per card 2x 10Gb Ethernet Adapter 6x - PCIe Gen2 Slots (+2 additional)

(4x) Intel Xeon CPUs

(2x) 120mm Hot Swap Fans

RAID (0/1) standard, RAID 5/6 Optional 2x 60mm Hot Swap Fans (8x) Gen2 2.5 Drives or 2 FlashPacks Light Path Diagnostics
This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

DVD Drive

Dual USB
109

IBM System x and BladeCenter

Imagens CPU e Memoia

CPU and Heatsink installation

Memory Cards

110

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System Images Interior Vista superior


SAS Backplanes + HDD Cage

Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7

M5015 RAID

PCIe x16 PCIe x4 PCIe x8 PCIe x8 PCIe x8 PCIe x8 PCIe x8


Boxborro1 Boxborro 2

HS Fan Pack Mem Card 8 Mem Card 7


System Recovery Jumpers

CPU4

PS1

CPU3 CPU2

Mem Card 6 Mem Card 5

USB

Mem Card 4 Mem Card 3

PS2

CPU1

Mem Card 2 Mem Card 1

111

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

x3850 X5 to MAX5 QPI cabling

eX5 Memory Drawer End

x3850 X5 End

112

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

X3690 X5 Nova realidade no padro de mqs Rack 2Us

113

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

x3690 X5: 2-socket 2U (Nehalem EX) platform


(1x) x16 (full height, full length or (2x) x8 (1 full size, 1 full height / half length) (2x) PCIe x8 Low Profile (1x) PCIe x4 Low Profile for RAID 32 x DDR3 Memory DIMMs 16 in upper mezzanine (pictured) 16 below (4x) N+N 675W Rear Access Hot Swap Redundant P/S

Scaling ports

Light Path Diagnostics

8x Memory Buffers DVD Drive (4x) 60mm Hot Swap Fans Dual USB (16x) Gen2 2.5 Drives or 3 FlashPacks

114

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System x3690 X5

Two PCI Express x8, one full size, one half length Two PCI Express x8, low profile Dedicated slot for 10Gb adapter

Ethernet port for Integrated Management Module (IMM) Optional IBM Virtual Media Key enhances functionality

Video Port

Serial Port

QPI Ports

Four USB Ports

Two redundant Ethernet ports

Up to four hot-swap power supplies with PFA (675W, 92% efficient)

115

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


Unified Extensible Firmware Interface (UEFI) Intelligent Platform Module Interface (IPMI) 2.0 Trusted Platform Module (TPM) 1.2 QPI speed burst or scalability card slot SSD expansion connector for up to two 1.8 drives PCI-e connector (CIOv) QPI speed burst or scalability card slot

Second two socket HX5 blade

Two socket HX5 blade

Four socket HX5 blade with FlexNode partitioning

USB hypervisor connector


116

Two Xeon processor sockets with PFA

Sixteen ECC VLP DDR3 DIMM sockets with PFA

PCI-e connector (CFFh)

Redundant midplane connections


2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

HX5 2- & 4-Socket Blade Top view of 4-socket system shown


2x SSD drives (1.8)

2x IO Expansion Slots (1x CIOv + 1x CFFh)

16x VLP DDR3 Memory 2x Intel Xeon EX CPUs

8x memory buffers

2x 30mm nodes Scale Connector Additional Features Internal USB for embedded hypervisor Dual & redundant I/O and Power Optional RAID 5 with battery backed cache IMM & UEFI
117

HX5 Configurations
2S, 16D, 8 I/O ports, 30m 4S, 32D, 16 I/O ports, 60mm
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

HX5 with MAX5


2S Blade + Memory Blade Mechanical Side view
(24x) DDR3 Memory DIMMs Upper Blade

6x Intel Memory Buffers

Firehawk memory and node controller

(16x) DDR3 Memory DIMMs Lower Blade

(2x) Intel Xeon EX CPUs

118

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

eX5 Scalability and Configuration Flexibility


x3850 X5 / x3950 eX5 Scaling
x3850 X5 4U
QPI

Westmere EX systems only

x3950 X5 4U x3850 X5 4U
QPI QPI

4P, 64 DIMMs

x3950 X5 4U
Memory Drawer 1U

x3950 X5 4U

Memory Drawer 1U

8P, 128 DIMMs

4P, 96 DIMMs
QPI

EXA

x3950 X5 4U
Memory Drawer 1U

x3690 X5 Scaling
X3690 X5 2U

8P, 192DIMMs

2P, 32 DIMMs
x3690 X5 2U
Memory Drawer 1U

QPI

HX5 Scaling

2P, 64 DIMMs

MAX 5 Scaling

2P, 16D 30mm 4P, 32D 60mm 2P, 40D 60mm


119

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

11 9

IBM System x and BladeCenter

eX5 Scalability and Configuration Flexibility Future !


QPI QPI QPI

x3850 X5 4U
QPI

x3850 X5 4U x3850 X5 4U

x3850 X5 4U
QPI
Memory Drawer 1U

x3850 X5 4U
Memory Drawer 1U

x3850 X5 4U
Memory Drawer 1U

x3850 4U
Memory Drawer 1U Memory Drawer 1U

x3850 X5 4U
QPI
Memory Drawer 1U

EXA

x3850 X5 4U
QPI
Memory Drawer 1U

EXA

QPI

Memory Drawer 1U

QPI

Memory Drawer 1U

Memory Drawer 1U

x3690 X5 2U
QPI

x3850 4U

x3690 X5 2U
Memory Drawer 1U

HX5 Scaling

2P, 16D 30mm

4P, 32D 60mm

6P, 48D 90mm

8P, 64D 120mm

2P, 40D 60mm 4P, 80D 120mm


2012 IBM Corporation

120

This document is for IBM and IBM Business Partner use only

EXA

x3690 X5 Scaling

QPI

QPI

x3850 X5 4U

EXA

x3850 4U

EXA EXA

x3850 4U

EXA

IBM System x and BladeCenter

5 mins para recordar...........e assim no esquecer.. !!!!! 1) Qual ferramenta oficial de X para criar config ? 2) x3550 e x3650, quantos Us tem cada um ? 3) O que Nehalem mesmo ? Cidade localizada no estado norte-americano de Oregon, no Condado de Tillamook. 4) O que significa EXA ? 5) Qual o nome do PDF que usamos como CA ?

121

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

O novo padro em performance de storage eXFlash entrega tecnologia solid-state disk integrada e uma arquitetura de controladora de alta velocidade

Mesma performance que

800
Discos mecnicos

Para a mesma Performance de database Mais baratos com 1000 usurios

97%

Consumo de energia reduzido a

1%
Dos discos mecnicos

122

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Aproveite a flexibilidade inovadora. FlexNode habilita a transformao dinmica de um sistema em dois independentes e capaz de junt-los novamente depois. Otimize workloads: Rode Um sistema 4S aplicaes interativas durante o dia em um sistema de 2S e aplicaes em batch a noite, em sistema de 4S. Ajude a reduzir custos com software: Execute em parties para otimizar custos de licenciamento de software quando carregados por ncleo de sistema. Aumente a segurana: Isole workloads para aumentar segurana e garantir qualidade de servio.
123

Dois sistemas 2S

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Simplifique a implementao
Virtual Fabric foi estendida ao portfolio eX5

Evite planejamentos de capacidade complexos em LAN vs. SAN: Virtual Fabric pode ser Ethernet, FCoE, and iSCSI Aloque banda onde for necessrio: Aplicaes crticas ficam com mais banda, enquanto projetos ou testes ficam com um percentual da mesma Use menos hardware: Menos adaptadores e switches necessrios para suportar o mesmo workload, com a tecnologia do IBM Virtual Fabric.

Qualquer

Tecnologia ou velocidade de rede

50% 75%

Menos adaptadores

Menos mdulos de switch

124

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

System x3755 M3

Servidor de alta performance, maior disponibilidade de memria e performance por Watt muito superior

125 125

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

126

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

127

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

128

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

129

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Diferencie-se com opcionais IBM


http://www-03.ibm.com/systems/info/x86servers/serverproven/compat/us/

Porque oferecer opcionais IBM? 1. Garanta o funcionamento da soluo 2. Obtenha garantia de 3 anos on-site na soluo 3. Fidelize seu cliente
UPS

Cons oles

KVM Racks

130

This document is for IBM and IBM Business Partner use only

PDU

2012 IBM Corporation

IBM System x and BladeCenter

Placa controladora M5015 com criptografia de dados


Placa controladora SAS/SATA, capaz de fazer criptografia nativa (opcional) Impossibilita roubo de informao ou vazamento de dados em caso de discos descartados ou furtados.
http://www.redbooks.ibm.com/abstracts/tips0054.html?Open

Ideal para ambientes que necessitam atender aos requerimentos HIPAA e SOX.

RAID 0, 1, 10, 5, 50, 6, 60 Cache fixo de 512MB Bateria anexada ao adaptador Encriptao de dados com chave armazenada localmente

131

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM RDX: simples e seguro !


O melhor da Fita e HD em um s componente: Grande capacidade: Cartuchos RDX oferecem at 500GB RDX possuem menor custo que as tecnologias anteriores de fita DDS Confiabilidade & Durabilidade: Design a prova de choque, sem perda de performance por vibraes Soft Eject evita perda de dados Cartuchos podem ser protegidos com criptografia e senha (HIPPA compliance) Simplicidade e Flexibilidade: Permite copiar dados simplesmente arrastando Interface USB 2.0 / Plug & Play Proteo do investimento: Drives compatveis com as prximas geraes
132

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Subsistemas de Memria Evoluo RAM

DIP (Dual In-line Package) 8080 330 Chips para 4MB SIPP (Single In-line Pin Package) 80286 30 pinos SIMM (Single In-line Memory Module) 72 pinos DIMM (Dual In-line Memory Module) Dados trans. 64 bits RDRAM (Rambus Dynamic RAM) PC800 Royalties Intel DDR SDRAM (Double-date-rate synchronous) 200MHz DDR2 SDRAM Dobro de velocidade da DDR DDR3 SDRAM Reduo de consumo eltrico 40%

133

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Memria para servidores High Volume

Novas caractersticas para otimizao de sistemas Novo! Suporte de UDIMM Pentes com at 4GB Preos menores em relao tecnologia RDIMM RDIMMs Mais capacidade com avanado sistema de deteco de falhas IBM recomenda RDIMMs para capacidade, confiabilidade e performance Novo! Mais performance em workloads (1333MHz) com 2x pentes DIMMs por canal Novo! Baixa voltagem 1.35V DIMMS em Xeon 5600 15% menos consumo de energia

Why IBM Memory


Compatibility tested & tuned for optimal performance Tested to meet IBM signal clarity & electrical tolerances Specs integrated into Light Path Diagnostics for continual feedback & optimum uptime IBM memory covered by the system warranty Seamless worldwide IBM service & support

134

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Memory ranks
A performance dos bancos baseda na quantidade de chips e do interleaving Dual rank DIMMs so mais rpidas (poucos chips e interleaving ajustado) DIMMs mais rpidos tm menos chips e maior densidade. No entanto, single rank DIMMs no so intercalados Verde o mais rpido (dual ranked DIMM, interleaved) Vermelho de velocidade mdia (single ranked DIMM, no Interleaving) Amarelo o mais lento de todos (quad ranked DIMM, interleaved)

Quad rank

Dual rank

Single rank

*Not actual chip layouts

135 13 5

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

ECC Error Correction Codes

Padro de MERCADO para correo de erros; Permite detectar 2 e corrigir um nico erro para cada 8bits; Envia alertas de PFA

136

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Fully Buffered DIMM Memory


Introduz o AMB chip entre a controladora de memria e os chips de memria; A controladora de memria no escreve diretamente nos bancos do pente, isso feito pelo AMB; O AMB compensa a deteriorao do sinal, bufferizando e reenviando o sinal (Leitura e Escrita); Oferece correo a erros sem overhead do processador ou da controladora de memria, reduzindo erros de comando ou endereamento; Permite aumento de banda nas controladoras de memria.

137

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Memory ProteXion
Utiliza bits redundantes em pacote de dados para recuperar falhas de memria; Diferentemente da tecnologia ECC padro que utiliza apenas 6 bits para correo dos erros, ProteXion utiliza mais dois para redirecionamento/endereamento nos bancos de memria (O ECC reconstri os dados e ProteXion armazena-os, utilizando os bits restantes); Uma falha no causa um chamdo de PFA, mas duas, alerta o sistema para substituio da memria; Esses dois bits no utilizados normalmente, so acionados apenas em caso de falha.

138

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Memory Scrubbing

Testa diariamente e automaticamente todo o sistema de memria; Detecta e reporta erros de memria antes de causar inoperncia no sistema; Ocorre uma vez por dia, caso haja mais de 64Gb de memria instalada; Se o Erro : - Recupervel: Memory ProteXion habilitado e o dado reescrito em um novo local - No-recupervel: Uma mensagem de erro enviada ao LightPath Diagnostics.

Obs: Essa funcionalidade foi criada no intuito de contornar problemas de interferncia externa (Raios csmicos ou Partculas Alpha). Os erros causados por este tipo de fenmeno so chamado de Soft Errors, so raros, mas ocorrem.

139

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Advanced ECC e ChipKill Memory


Chipkill uma tecnologia dos subsistemas de memria da IBM que aumenta a confiabilidade do dados armazenados nas memrias.

Esta funcionalidade, exclusiva IBM, performada atravs do espalhamento das informaes de ECC atravs de mltiplos chips ao longo do subsistema de memria, permitindo a reconstruo do dado antes mesmo que o chip falhe. Opera com 288 bits: 256 bits para dados 32 bits para checksum Pode perder at 8 bits simultaneamente em quaisquer chips do mdulo DIMM
140

100x mais efetiva que ECC; Detecta e corrige at 4 bits por DIMM, escrevendo um valor de checksum (checagem por meio de soma aritimtica ) em outra parte do subsystema de memria; Mantm a mquina rodando enquanto torna offline o chip com problema;

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Resumo Traduzir urgente


Chipkill & ECC Memory
Integrated into EXA chipsets for using off-the-shelf DIMMs Better memory reliability to support In-Memory Databases Chipkill Memory enables increased availability by detecting and correcting multiple-bit memory DIMM errors Third-Generation Chipkill design

Memory ProteXion - Redundant Bit Stering


Redundant Bit Steering similar to "hot-spare" of a DASD Array Utilizes unused bits in each memory DIMM (hot spare bits) Double the number of Chipkills sustainable per server Included at no additional cost, requires no additional hardware, and works independently of operating system

72 Bit DIMM 64 Bits Data 6 Bits ECC 2 Bits Spare

Memory Mirroring + Hot-swap & Hot-add


Propels Intel-based servers towards continuous operations Dramatically increases uptime and allows maintenance Mainframe capability and reliability Operating System Independent: No drivers or OS support First introduced on the x440 and x445

141
141
141

Key points for database serving and multiple application hosting!


This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

IBM System x and BladeCenter

Gerenciamento In-Band e Out-Of-Band IN-BAND:


Gerenciamento envolvendo Softwares Utiliza agentes de gerenciamento, camadas: OSA Driver IPMI Mapper IPMI/CIM (SO)

OUT-of-BAND:
Gerenciamento via HW IMM RSA II SLIMLINE BMC MINI-BMC CIM

142

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Sistemas de Gerenciamento Integrado

miniBMC

BMC

Adaptadores de gerenciamento dos Sistemas

Camada 1
Funcionalidade
Compatvel com IPMI 1.5 Monitora voltagem, temperatura, bateria Dirige o sistema de LEDs (Sem LightPath) Control de Energia, System Reset e reboot.

Camada 2
Funcionalidade
Mesmas funcionalidades do Mini-BMC, mais: Compatvel com IPMI 1.5 or 2.0 (dependendo do modelo) Serial over LAN (SOL) Comunica o LightPath

Camada 3
Funcionalidade
3 formatos de fabricao (PCI-X, Add-on Module, AMM Interface Web e full SSL LDAP integration para autenticao de usurios Suporte a KVM remoto padro Midia virtual remota DNS, DHCP, SNMP , SLP

143

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IMM Novo Integrated Management Module

Controle remoto para gerenciar, monitorar e realizar anlise de falhas de qualquer lugar do mundo!

Recurso
Reduo dos custos de TI Firmware unificado entre todos os sistemas Alertas baseados em padres

Benefcios para os clientes


Fornce diagnsticos, controle remoto para monitorar e realizar manutenes de qualquer lugar com conexo internet. Conexo segura independente de SO da estao. Possibilita deploy do servidor de forma remota via Remote Midia. Um nico firmware para todos os servidores. Facilita a administrao de grandes quantidades de equipamentos O IMM integrado ao IBM Systems Director 6 oferece alertas e status de forma segura e eficiente. Alertas baseados em padres permitem a integrao com outros sistemas de gerenciamento de mercado.

144

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IMM Virtual Media Key

Hardware Key que se conecta system board do servidor Oferece controle remoto com o KVM e capacidade de Remote Disk para o IMM Utiliza slot dedicado na system board

IMM Virtual Media Key

145

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Componentes Codificados por Cores

Projeto intuitivo para facilitar manuteno

Abas Azuis
Componentes NO HOT-SWAP Identifica os componentes que podem ser removidos sem o uso de ferramentas com o servidor DESLIGADO

Abas Terracota - Laranja


Componentes HOT-SWAP Identifica os componentes que podem ser substitudos ou operados com o servidor em funcionamento, LIGADO

146

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Tecnologia Calibrated Vectored Cooling

Design que garante a perfeita refrigerao do servidor mesmo em condies extremas


Componentes eletrnicos e mecnicos projetados em conjunto Otimizao do fluxo de ar

Tecnologia:
Tacmetro Mede o nmero de rotaes Velocidade varivel para garantir temperatura constante e fail-over

147

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Novo UEFI (Unified Extensible Firmware Interface)

Substitui o antigo BIOS Elimina o limite de 2TB para parties Avano para 4PTB (PetaBytes) Fornece ambiente de pr-boot com total suporte a rede Acessa diretamente toda a memria RAM (em 64bits) Elimina o limite de adaptadores PCI (e problemas de alocao de memria)

http://www947.ibm.com/systems/support/reflib/simulat ors/options/uefi/index.html

148

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Portflio IBM Storage O mais completo portflio do mercado

149

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Exploso de dados em um Planeta mais inteligente


Em 2012:
Vendas de celulares com cmera superaro 1,5 bilho de unidades (Strategy Analytics); Segundo estudo da ABI Research, o envio total global de SMS em 2012 ser de 7 trilhes de mensagens;

Brasil chega a 12.9 milhes de dispositivos 3G em 2011 segundo a Anatel, praticamente triplo em relao 2009; IDC estima venda de 700 mil tablets no Brasil em 2012; Mais de 108 milhes de iPhones foram vendidos entre 2007 e 2011; Cerca de 60 milhes de iPods touch foram comercializados no mesmo perodo...

150

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Vantagens da Venda CROSS System x e Storage


o Mantendo a concorrncia longe
Levante a barreira contra a concorrncia
- Oferecer a soluo completa dificulta a penetrao da concorrncia - Vender apenas o servidor deixa a porta aberta para a concorrncia entrar com o Storage - Ao no vender a soluo a IBM e os parceiros no sero vistos como consultores de negcios

System x portfolio

IBM Storage portfolio

151

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Desafio de Storage interno a servidores


ESCALABILIDADE DE DISCOS Os limites de capacidade interna dos servidores so atingidos muito rapidamente GERENCIAMENTO SIMPLES Os dados armazenados em mltiplos servidores tornam a gesto ineficiente, complexa, reativa e com funcionalidades limitadas FCIL ACESSIBILIDADE Dados espalhados em mltiplos servidores, dificultam o acesso informao e aumentam o tempo de resposta ao usurio PROTEO DE DADOS A perda de dados, alm de prejudicar a produtividade das empresas, tambm resulta na perda de renda, lucros, e reputao

152

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Desempenho em Storage Mtricas Bsicas para Storage


IOPS (I/O por segundo) I/Os randmicos, em blocos pequenos Aplicaes transacionais como OLTP, bases de dados e Exchange

Throuput (MB/s) I/O sequenciais, em blocos grandes Aplicaes intensivas de dados, como videos, sons, modelamento 3D e simulaes

153

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Tecnologias de discos (HDD)


SSD
O mais alto desempenho, mas com o mais alto custo Melhor opo para aplicaes misso crtica e aplicaes transacionais (demanda por IOPS) - como OLTP, bases de dados, Exchange - aplicaes onde o desempenho prevalece contra custo

FC ou SAS
Alto desempenho Excelente opo para aplicaes misso crtica e aplicaes transacionais (demanda por IOPS) - como OLTP, bases de dados, Exchange - aplicaes onde o desempenho prevalece contra custo

SATA ou Near Line SAS


Excelente $/GB Generalmente recomendado para aplicaes Tier 2 como contedo fixo, backup-to-disk, servidores de file and print aplicaes onde o custo prevalece contra desempenho
This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

154

IBM System x and BladeCenter

Padres de acesso a dados


Recomendao: SSD, FC ou SAS

IOPS
Intensivo em I/O Intensivo Acesso Acesso em taxa de randmico sequencial transf.

Leitura intensiva OLTP Data warehouse Servidor de Arquivos Imagens Mdicas Web / Internet Multimedia Imagens de documentos CAD/CAM Backup / recovery

Escrita intensiva

Recomendao: SATA ou NL SAS

MB/s
2012 IBM Corporation

155

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Portflio IBM System Storage no Brasil


Entry Disk System Midrange
SAN Volume Controller (SVC)

High-End

EXP3000

EXP2500 DS3500 DS3400 DS5020 Storwize V7000 DS5100/5300 XIV DS8700 DS8800

N Series

N3000 N6000 N7000 SONAS

Tape System

TS7600 ProtecTIER Deduplication TS2230, TS2240, TS2250, TS2340, TS2350

TS2900

TS3100

TS3200

TS3310

TS3500

TS7000 SAN256B / SAN348B / SAN768B / MDS 9500


2012 IBM Corporation

SAN

MDS 9124

SAN24B-4

MDS 9134

SAN40B-4

MDS 9148

SAN80B

156

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

EXP2500 Gaveta de expanso de capacidade para System X


Simplicidade e desempenho atravs das tnterfaces SAS de 6Gbps para servidores e discos Facilidade de instalao e gerenciamento conexo direta a servidores System x via adaptador ServeRAID M5025 Flexibilidade de discos SAS 2.0 (desempenho) e/ou NearLine SAS 2.0 (capacidade com baixo $/GB) At 432 discos em at 18 gavetas cascateadas!! Fontes AC e ventoinhas duais

EXP2512 (3.5 HDs) EXP2524 (2.5 HDs)


157

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Portflio IBM System Storage no Brasil


Entry Disk System Midrange
SAN Volume Controller (SVC)

High-End

EXP3000

EXP2500 DS3500 DS3400 DS5020 Storwize V7000 DS5100/5300 XIV DS8700 DS8800

N Series

N3000 N6000 N7000 SONAS

Tape System

TS7600 ProtecTIER Deduplication TS2230, TS2240, TS2250, TS2340, TS2350

TS2900

TS3100

TS3200

TS3310

TS3500

TS7000 SAN256B / SAN348B / SAN768B / MDS 9500


2012 IBM Corporation

SAN

MDS 9124

SAN24B-4

MDS 9134

SAN40B-4

MDS 9148

SAN80B

158

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

DS3200/3300/3400 Specifications Overview


DS3200
One or three 3-Gbps SAS host ports per controller

DS3300
Two 1-Gbps iSCSI host ports per controller

DS3400
Two auto-negotiating 4-Gbps FC host ports per controller 3 Gbps SAS controllers (simplex and dual controllers)
Mirrored battery cache (1GB per controller upgradable to 2GB size) 1 or 2 controllers in a 2U drawer with 12 embedded drive slots 1 internal 3Gbps SAS ports per controller SAS: 73, 146, 300, 450, 600 GB (15K) SATA: 500, 750, 1000, 2000 GB (7.2K) Up to 12 drives per drawer (SAS and SATA drive intermix supported) Max of 48 drives in 4 drawers (including controller drawer)

Controllers/ESMs SAS and/or SATA drives

SAS/SATA drives 3.5

Up to 3 EXP3000 expansion drawers (2U)

Support for System x servers, System p servers*, and BladeCenter servers RAID levels: 0, 1, 3, 5, 6, 10 Redundant, hot-swappable components and unlimited global hot spare Maximum 256 logical drives (up to 32 per partition), 255 copies Premium features supported:
Partitioning - 4, 8, 16 or 32 FlashCopy - 2, 4 or 8 targets per base (max 64 pairs per system) VolumeCopy

Power/cooling

3 Year warranty, 9x5, NBD response, CSU & CRU (optional call home and dial in with RSM)
(*) not on DS3200
159

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM System Storage DS3500 Express


Storage com arquitetura SAS de 6 Gbps

Storage entry-level com desempenho de midrange, escalabilidade e Replicao Remota (ERM) Perfeito para solues Microsoft e Vmware de pequeno porte Conectividade multi-protocolo com suporte a DAS e SAN FC ou SAN iSCSI Fcil de usar com um software de gerenciamento fcil, intuitivo e seguro Desempenho balanceado ideal para cargas de trabalho heterogneas e virtualizao Mais segurana e proteo dos dados

160

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

DS3500 - Viso geral


Dual-active e controladoras hot-swappable Quatro portas SAS 6 Gbps padro (field upgradeable) podendo-se adicionar:
Quatro portas SAS de 6 Gbps Oito portas FC de 8 Gbps Oito portas iSCSI de 1 Gbps Quatro portas iSCSI de 10 Gbps

Duas portas SAS 6Gb com suporte para at 192 discos


Discos SAS, NL SAS e FDE SAS de alto desempenho Novas gavetas de expanso EXP3512 (2U 12x3.5 HDs) e EXP3524 (2U 24x2.5 HDs)

Cache de dados espelhado, protegido por bateria e cache destage


2GB da cache padro, com disponibilidade para at 4GB

Desempenhos Base e Turbo


Turbo: 200.000 IOPS e 1.600 MB/s

IBM DS Storage Manager


Software de gerenciamento robusto e intuitivo Espelhamento Remoto via porta FC

DS3512 (3.5 HDs) DS3524 (2.5 HDs)

161

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

DS3500 Flexibilidade e Eficincia

(4) Portas SAS + (4) portas SAS Ideal para VMware e Microsoft
2012 IBM Corporation

Pode entregar desempenho mximo Excelente para ambientes DAS Consolidao com BladeCenter suporte a boot via storage

(4) Portas SAS + (8) portas FC


Aumento da conectividade em ambientes heterogneos Suporte para ambientes DAS e FC SAN Suporte a espelhamento remoto via FC

(4) Portas SAS + (8) portas iSCSI


Aumento da conectividade em ambientes heterogneos Soluo de baixo custo ideal para ambientes secundrios Suporte a SAN via IP

162

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

DS3500 Specifications Overview


DS3500
6 Gbps SAS controllers (simplex and dual controllers)
Mirrored battery cache (1GB per controller upgradable to 2GB size) 1 or 2 controllers in a 2U drawer with 12 or 24 embedded drive slots 2 internal 6Gbps SAS ports per controller Supports field installable daughter cards & hot-swappable CRUs

DS3512 (1746-C2A)/EXP3512
12 x 3.5-in high performance, nearline, and selfControllers/ESMs encrypting SAS drives
300, 450 & 600GB (15K rpm) 600GB (SED 15K rpm) 1 & 2TB (7.2K rpm)

Optional turbo performance feature provides 30% IOPS improvement; 100% MB/s improvement An optional daughter card per controller
Two 6Gbps SAS ports (4 with dual controllers) Four 8 Gbps FC ports (8 with dual controllers) Four 1 Gbps iSCSI ports (8 with dual controllers) 2U disk enclosures: Up to 7 EXP3512 (12x3.5-in drives) and up to 3 EXP3524 (24x2.5-in drive)
6 Gbps SAS ESMs (single ESM standard with second ESM optional) Dual Power/Cooling units Hot-swappable CRUs

Drives

Up to 96 SAS drives

Power Cooling

DS3524(1746-C4A)/EXP3524
24 x 2.5-in high performance, nearline, and selfencrypting SAS drives
146GB (15K rpm) 300GB (10K rpm) 300GB (SED 10K rpm), 500GB (7.2K rpm)
Controllers/ESMs

Two 6 Gbps SAS drive interfaces

RAID levels: 0, 1, 3, 5, 6, 10 Redundant, hot-swappable components & unlimited global hot spare Maximum 256 logical drives (up to 32 per partition), 255 copies Premium features supported:
Full disk encryption Partitioning 4 (standard), 8, 16, 32, 64 FlashCopy 2 (standard) 4, 8 per storage system Volume Copy Remote Mirroring across FC host ports 8 per storage system

3 Year warranty, 9x5, NBD response, CSU & CRU (optional call home and dial in with RSM)
163

Power Cooling Drives

document is for IBM and IBM Business Partner use only Click on This the slide to return to the main slide

2012 IBM Corporation

IBM System x and BladeCenter

Portflio IBM System Storage no Brasil


Entry Disk System Midrange
SAN Volume Controller (SVC)

High-End

EXP3000

EXP2500 DS3500 DS3400 DS5020 Storwize V7000 DS5100/5300 XIV DS8700 DS8800

N Series

N3000 N6000 N7000 SONAS

Tape System

TS7600 ProtecTIER Deduplication TS2230, TS2240, TS2250, TS2340, TS2350

TS2900

TS3100

TS3200

TS3310

TS3500

TS7000 SAN256B / SAN348B / SAN768B / MDS 9500


2012 IBM Corporation

SAN

MDS 9124

SAN24B-4

MDS 9134

SAN40B-4

MDS 9148

SAN80B

164

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Storage em Fita: $/GB Imbatvel para Backup e Archive


Fita no est morta! Vida longa fita!!
Tape is able to store a lot of data in a very small package Currently available tape drives can deliver sequential transfer speeds that rival the fastest hard disks available. Tape media can be removed from its drive, shipped, stored, and used years later
http://www.infoworld.com/d/data-explosion/tape-dead-long-live-tape-090

Benefcios da LTO5 IBM


IBM Long Term File System: drives de fita visualizados como mdia removvel o Arquivos e pastas em fitas so apresentados em diretrios o Drag-and-drop de arquivos e pastas para/de fitas Reduo de: o Custos versus LTO4: 37% menos $/GB e at 48 % menor consumo de energia. o Custos verus Discos SATA: 23X mais barato em $/GB, e at 300x menos energia o Tempo: back-up de arquivos de 1 GB em menos de 8 seg. Proteo de investimento: Padro LTO oferece compatibilidade reversa entre geraes Atendimento de requisitos regulatrios: cartuchos WORM e Encriptao de dados
2012 IBM Corporation

Gerao DAT-40 (DDS-4) DAT-72 (DDS-5) DAT-160 (DDS-6) LTO-3 LTO-4 LTO-5

Lana- Cap. Nativa / Mx. Taxa de mento Cartucho Transf. 1999 20 GB 3,2 MB/s 2003 36 GB 3,2 MB/s 2007 80 GB 6,9 MB/s 2005 400 GB 80 MB/s 2007 800 GB 120 MB/s 2010 1.500 GB 140 MB/s

165

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Por qu proteo de dados? Inmeras ameaas podem corromper e destruir dados


Forrester Research: Mais de 25% das organizaes tiveram um desastre nos ltimos 5 anos1 76% das organizaes tiveram uma interrupo severa de operaes1

ACIDENTES Desastres naturais Erros de sistemas Erros operacionais INTENCIONAIS Virus Roubo Hackers Sabotagem Displicncia

Riscos de downtime Perda de renda e participao no mercado Perda de produtividade No atendimento de regulamentos Perda de reputao e confiana dos clientes Perda do negcio
1

166

Building the Business Case for Disaster Recovery Spending, Forrester Research, Abril 2008 This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Subsistemas de Disco Interfaces histrico

167

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

168

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Host logical drive restrictions by N.O.S.

Segment size

169

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 0 Data Striping Striped Sequentially

170

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 1 and RAID 10 Disk Mirroring and Mirroring with Striping

171

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 1E Enhanced = Striping with Mirroring

172

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 5 Data Striping with distributed parity

173

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Enhanced RAID 5E = Data Striping with distributed parity and hot spare across hard disks

174

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 6 = Data striping with dual distributed parity

175

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 00 = Striping entre arrays

176

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

177

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 10 = Striping do espelhamento entre arrays

178

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

179

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 1E0 = Striping do RAID 1E entre arrays

180

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

181

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 50 = Striping do RAID 5 entre arrays

182

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 5EE = Striping dos blocos de hot-spare do RAID 5E

Vantagens: Melhor performance em relao ao RAID 5 100% de proteo dos dados Reconstruo dos dados mais rpida que RAID 5E Desvantagens: Performance inferior aos RAID 1 e 1E Suporta apenas UM drive lgico por array

183

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RAID 60 = Striping do RAID 6 entre arrays

184

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Mulheres, muito obrigado por vocs existirem, muito obrigado por fazerem parte de nossas vidas, obrigado por nos aturarem e por nos colocarem no mundo! Sem vocs, no existiriamos!

PARABNS!
185

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter!

42 servidores de 1U

42 lminas HS22

186

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Porque Blades?
Ethernet Cables

Fibre Switches

Fibre Cables

Ethernet Switches

KVM Cables KVM Switch Power Cables


187

Servers

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Simplificando a complexidade da infra-estrutura


Firewalls Routers (Layer 3 Switches)

Public Internet/ Intranet Clients

Layer 4-7 Switches

Layer 2 Switches

Network Servers

Application Servers

Security Servers

Application Servers

Web Servers

Security Gateway

File Servers

WebSphere Application Servers

Storage Network

Storage Network

SAN

188

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Integra a primeira camada de rede Switchs (L2)


Layer 4-7 Switches

Public Internet/ Intranet Clients Firewalls Routers (Layer 3 Switches)

Layer 2 Switches

Storage Network

Storage Network

SAN

189

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Integra a segunda camada de rede Switchs (L4-7)


Firewalls Routers (Layer 3 Switches)

Public Internet/ Intranet Clients

Layer 4-7 Switches

Storage Network

Storage Network

SAN

190

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Integra Switchs Fabric para Storage


Public Internet/ Intranet Clients Firewalls Routers (Layer 3 Switches)

Storage Network

Storage Networks

SAN

191

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BC S chassis com Storage integrado

Public Internet/ Intranet Clients Firewalls Routers (Layer 3 Switches)

SAN

192

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Resumindo, sua infraestrutura enxuta! Gerenciamento simplificado Reduo do cabeamento SAN


Layer 4-7 Reduo do cabeamento LAN Switches
Firewalls

Firewalls Routers (L3 Switches)

Public Internet/ Intranet Clients Public Internet/ Intranet Clients

Routers

Layer 2 Consolidao dos switchesSwitches no chassi

Eliminao dos custos com Network Application Security Application KVM Servers Servers Servers Servers Reduo dramtica nos custos com PDU
SAN Preservao do espao, manuteno da temperatura e consumo eltrico
193

Web Servers

Security Gateway

File WebSphere Servers Application Servers

Storage Fibre Switches Storage Fibre Switches

SAN

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Componentes da soluo BladeCenter

Server on a card cada Blade possui seu prprio: Processador Memria Ethernet Storage (opcional) Chip de gerenciamento de sistemas O chassis proporciona
compartilhamento de: Console de gerenciamento (KVM) Fonte de energia Ventilao Switches de rede Switches de fibra Drive de CD-ROM Drive de diskette Portas USB
194

IBM Blade - with its cover on - ready for insertion into the BladeCenter

IBM BladeCenter chassis - 7U rackable

Infraestrutura totalmente redundante para mxima disponibilidade e tolerncia a falhas


This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

IBM System x and BladeCenter

Blades, ideal para

Aumento de Controle
Implementaes rpidas e gerenciadas Infraestrutura Gerencivel

Ferramentas Tecnologia Flexibilidade

Custos Reduzidos
Aquisio Instalao Implementao Ambiental Ciclo de vida

Complexidade Reduzida
Instalao Simplificada Infraestrutura Integrada Arquitetura Flexvel

195

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Reestruturao do Datacenter Viso traseira

Reduo de 86% da utilizao de cabos

196

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Voc quer continuar vivendo perigosamente ? ? ?

197

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

198

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Produto ecolgicamente correto! Recursos naturais preservados!

199

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Simplificao com BladeCenter, para ter benefcios!

14 Node 1U 14U 28 power cables 84 fans 28 power supplies 36 Ethernet cables 14 KVM cables 4 Power Distribution Units 2x KVM Switches Power consumption: 7.7KVA Heat dissipation: 26292 BTU/hr

7U 4 power supplies 4 power cables 2 fans 8 Ethernet cables 4 FC cables 1 Power Distribution Units No KVM Switches Power consumption: 4KVA Heat dissipation: 13648 BTU/hr

200

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Blade extende os beneficios para seu business!

Chassis adaptado s suas necessidades

IBM BladeCenter E
Enterprise, best energy, best density

IBM BladeCenter S
Distributed, small office, easy to configure

IBM BladeCenter H
High performance

Um conjunto comum de blades Um conjunto padro da indstria de switches e I/O fabrics Uma infra-estrutura simples de gesto
201

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Chassi Enterprise frontal

202

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Chassi Enterprise Traseira

203

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Chassi H Frontal

204

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Chassi H traseira

205

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

I/O Path - BladeCenter H com MSIM

Ethernet

Fibre Channel

On board Ethernet CIOv Ether. / FC

CFFh Combo
Ethernet/FC
Ethernet Fibre Channel

206

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

207

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter S rear view

208

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter S Ajuste perfeito ao seu ambiente de TI


SAS RAID Switchs

RAID
SAS Daughter Card System Storage TS2230 System Storage TS3100

BladeCenter S 6-Disk Storage Module x 2

DS3200 (Boot and data) EXP3000 for expansion

209

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter HS22 Novo Design, novos conceitos !

Optional RAID 5 w/ battery-backed write-back cache

Internal USB (Embedded Hypervisor) 2x Intel Xeon 5600 Processors (Nehalem EP) Additional Features IMM & UEFI Light Path Diagnostics Expansion blades BCE, BCH, BCS, BCHT

Dual and redundant power & I/O connectors

2 I/O Expansion Slots (1x CIOv + 1x CFFh)

2x hot-swap drive bays (SAS or Solid State)

12x VLP DDR3 Memory (96GB Max / 1333MHz Max)

210

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

211

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM BladeCenter HS22V


High density, high performance blade optimized for virtualization + energy efficiency Additional Features IMM & UEFI P-State Capping TPM 1.2 Light Path Diagnostics PCI Expansion Blade Internal USB (Embedded Hypervisor)

Dual & Redundant Power/IO

18x VLP DDR3 Memory (144GB Max / 1333MHz Max)

Same I/O as HS22 (1x CIOv + 1x CFFh)

212

2x 1.8 SSD NHS RAID 0/1 This document is for IBM and IBM Business Partner use only

2x Intel Xeon 5600 Series Processors 2012 IBM Corporation

IBM System x and BladeCenter

IBM BladeCenter HX5

Blade de 2 soquetes que pode escalar at 4 soquetes At 40 DIMMs por sistema de 2 soquetes com MAX5 Oito portas de I/O por sistema de 2 soquetes

Um servidor Blade escalvel, que permite padronizao para demandas de servidores com 2 ou 4 soquetes, entregando maior valor e produtividade em ambientes altamente densos.
213

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter HX5 Escalabilidade total!

2S, 16DIMM 30mm

2S, 40DIMM 60mm

4S, 32DIMM 60mm

Maximiza memria Minimiza custo Simplifica Deployment

IBM HX5

PCI-E

Intel Boxboro

PCI-E

Intel Boxboro

Intel NHM-EX
MB1 M M MB1 B1 B1

Intel NHM-EX
MB1 M M MB1 B1 B1

Intel NHM-EX

Intel NHM-EX

MB1 M M MB1 B1 B1

MB1 M M MB1 B1 B1

FireHawk

MB1 M M MB1 MB1 M B1 B1 B1


214

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

215

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter HX5 Conector para escalar 4S ou MAX5!

216

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Expanso para I/O, HDDs Hot e Memria no passado!

217

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Uma expanso de I/O ajudando a cincia, acelerando grficos! GPU Blade! Vista superior
High speed I/O slot; connection point when stacking BGEs

Dual/redundant power & I/O connectors para o midplane


218

NVIDIA Tesla M2070 GPU (or M2070Q)


This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

IBM System x and BladeCenter

IBM BladeCenter GPU Expansion Blade Design!


GPU conectada com blade HS22

IBM HS22 blade

IBM BladeCenter GPU Expansion Blade (BGE)

219

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Capacidade Stacking para 4 GPUs!

BGE #1

BGE #2

BGE #3

BGE #4

220

This document is for IBM and IBM Business Partner use only

HS22

2012 IBM Corporation

IBM System x and BladeCenter

Midplane, sinais duplicados, entre todos os componentes! GB Ethernet / Fibre Channel KVM Drive de DVD Sinal de Video Gerenciamento Alimentao Eltrica

Todos os sinais acima so duplicados nesse conector

Quais lminas possuem essa caracterstica?? Todos os modelos!!

221

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Midplane Superior e Inferior

=> Redundncia total

222

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Diferenciais do chassi IBM vs. Concorrente


Todas as lminas ofertadas pela IBM possuem conectores eltricos e conectores lgicos redundantes. Diferente das lminas BL460c (processadores Intel) e BL465c (Processadores AMD) do concorrente, que possuem apenas um conector eltrico e apenas um conector lgico. Nas lminas do concorrente todo sinal lgico (placas de rede, de fibra, etc) utilizam apenas um conector de I/O. O mesmo acontece com os conectores eltricos. Portando qualquer falha no conector de I/O ou eltrico, torna essa lmina indisponvel.

Todas lminas IBM desde 2002

BL460c e BL465c

223

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter - Arquitetura de comunicao para I/O

Inter Switch Links Ports 13-14

Inter Switch Links Ports 13-14

1X I/O expansion cards add NIC ports 3 and 4 to blade servers, connect to switches 3 & 4 respectively
224

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

225

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter E I/O Topology

226

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter H I/O Topology

227

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter S I/O Topology

Switch SAS RAID x 2

228

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter HS22 Conectividade superior (I/Os) e opcional !


On-board to Switch bay 1 & 2

HS22 CFFh options HS22 CIOv options 10Gb Ethernet 20/40Gb InfiniBand 1Gb Ethernet / Fibre

BladeCenter H BladeCenter E 10Gb Ethernet 20/40Gb InfiniBand MSIM

1Gb Ethernet 4/8Gb Fibre Channel 3Gb SAS

1Gb Ethernet 4/8Gb Fibre Channel 3Gb SAS Pass-thru

229

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Stacking Configuration

Primary 10G uplink to upstream Network (via XFP)

Copper Cables with CX4 Connections

42u high Rack with up to 6 Chassis

Client Benefits High speed (10 Gbps) communication between BladeCenter Chassis Collection of switches behave as one virtual switch, simplifying management Any individual switch can direct traffic to any blade in the rack, improving the entire racks High Availability characteristics

Secondary 10G up-link to upstream Network (via XFP)

230

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

I/O Recomendado para Virtualizao


Melhores Prticas de Mercado: 4 a 6 portas de rede GB Ethernet 2 a 4 portas SAN

CFFh Adapter CIOv Adapter Dual Gigabit Ethernet + Dual FC SAN Adapter
This document is for IBM and IBM Business Partner use only

Dual Gigabit Ethernet Adapter


231

2012 IBM Corporation

IBM System x and BladeCenter

CNA - Converged Network Adapter


Ethernet 10GB Fibre Channel Traffic

Ethernet 10GB Fibre Channel Traffic

- ETH e FC em uma porta de 10GB - Custo de placas e Switches menor -Ainda existe a necessidade de portas extras de rede
232

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Melhores Prticas de Mercado para ambientes virtualizados


IBM Virtual Fabric Tradicional

(2x) GB ETH

vNIC

vNIC

vNIC

vNIC

vNIC

vNIC

vCNA

vCNA

(6x) GB ETH

(2x) FC ETH (2x) GB ETH

- (x1) vMotion - (x1) vCenter - (x4) Produo - (x2) Storage


233

(2x) FC Ports (2x) GB ETH


This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

IBM System x and BladeCenter

IBM BladeCenter Virtual Fabric offers the Benefits of both Virtual NIC and IO Convergence on a Single end-to-end Solution.
FCoE Software License Upgrade*
Manang. + vMotion

Create Virtual groups and Assign one uplink per group

Virtual Groups

Virtual NICs

Prod.

CNA

Prod.2

Up to 8 Virtual Ports per adapter

Database

Configure few ports as Virtual CNA No separate HBA needed!

CNA

Map each Virtual adapter to port groups


234

This document is for IBM and IBM Business Partner use only

*Future Upgrade Option

2012 IBM Corporation

IBM System x and BladeCenter

Ambiente com Virtual Fabric


Pr-Requisitos do Virtual Fabric ?

ETH ETH FC ETH

Up to 8 virtual ports at flexible bandwidth

1x Virtual Fabric adapter

235

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Consolidao de I/O
IBM Blade Server
On-Board 1GbE CFFv

LAN SAN

CNA

LAN

IBM Blade Server


SAN

CNA

236

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

FCoE Top of Rack Switches


IBM Converged Switch B32
24 ports FCoE and 8 ports 8 Gbps FC

Cisco Nexus 5010 and 5020 for IBM System Storage

IBM QLogic Fabric Extension Module

237

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Emulex Virtual Fabric Adapter


2-Port 10GbE Highest performing 10GbE card @ IBM 49Y4235-BC 49Y4250-PCIe Dual 10GB Ethernet

pNIC iSCSI Hardware Acceleration FCoE

2-port ISCSI

Data + Storage networking with one cable

49Y4235-BC 49Y4250-PCIe

Dual iSCSI

2-port FCoE

Data + Storage networking with one cable

49Y4235-BC 49Y4250-PCIe

+ vNIC or pNIC

vNIC

Up to 8 Ethernet Virtual Ports

Tailor Bandwidth as required and multiple, simultaneous interfaces

49Y4235-BC 49Y4250-PCIe

+ FCoE or ISCSI

Modos

Descrio

Benefcios

P/N

Modos de Operao
2012 IBM Corporation

238

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Mdulo de Gerenciamento Avaado - AMM


Porta de Uplink Ethernet Video Serial Mouse e Teclado (USB)

Mdulo Standard

Mdulo Opcional

Funcionalidade de um Switch KVM local atravs te portas de video teclado e mouse. Interface 10/100 Mb Ethernet com os componentes do chassis e as 14 lminas para gerenciamento com funcionalidades semelhantes da RSA-II Hot-Swap com possibilidade de instalar um segundo aMM opcional para redundncia (fail-over).

239

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

BladeCenter: Redundncia N+N


Domain 2 Domain 1

50%

50%

50%

50%

Rede Eltrica 1

Rede Eltrica 2

240

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Redundncia N+N: Falha de uma Fonte de Energia


Domain 2 Domain 1

50%

X
50%

50%

100% 50%

Rede Eltrica 1

Rede Eltrica 2

241

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Redundncia N+N: Falha de uma PDU


Domain 2 Domain 1

50% 100%

50% 100%

50% 0%

50% 0%

X
Rede Eltrica 1 Rede Eltrica 2
242

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Redundncia N+N: Falha de uma rede eltrica


Domain 2 Domain 1

50% 100%

50% 100%

50% 0%

50% 0%

Rede Eltrica 1

Rede Eltrica 2

243

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Hot Spare Blades: Mito ou Realidade ?


Falhas de Hardware tpicas, que impedem o reinicio imediato do Servidor:

1. 2. 3.

System board nico Processador Ambos HDDs falham (Raid1)

Como implementar ? Dois exemplos tpicos: 1. Director Deployment wizard, que permite atribuir um perfil para um chassis. Utilitrio de linha de comando DIRCMD, selecionando um indicador de falha da lamina.
This document is for IBM and IBM Business Partner use only
2012 IBM Corporation

2.

244

IBM System x and BladeCenter

Ferramentas de desenvolvimento de SKILL e suporte em tecnologia BladeCenter!

245

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Planejar instalaes / Consideraes eltricas BC Parte 1

Vocs lembram dessa tecnologia KVM ?

246

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Planejar instalaes / Consideraes eltricas BC

Inovao e Controle Simplificando muito mais !!

ACT Cabling Technologies

Para Solues KVM Enterprise Tpicas

Solues inovadoras que ajudam a resolver os problemas de cabeamento em ambientes de alta densidade em rack
Hoje: C2T e IBM ACT Presena Virtual Remota Integrao com KVM

Design inovador
Reduo da profundidade dos servidores facilitando a instalao e gerenciamento de KVM Manuteno Livre de Ferramentas (Tool-less) Trilhos padres para compatibilidade com racks de mercado

Gerenciamento Lder da Indstria


Light path diagnostics Processadores de Gerenciamento Integrados Opes de Gerenciamento Remoto com console grfica em todos os servidores

At 16 Servidores por Chain

247

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter


39M2897 IBM Long KVM Conversion Option (4 Pack Long KCO) 43V6147 IBM Single Cable USB Conversion Option (UCO) 39M2895 IBM USB Conversion Option (4 Pack UCO)

39M2894 IBM Virtual Media Conversion Option (VCO)

46M5383 IBM Virtual Media Conversion Option Gen2 (VCO2)

46M5382 IBM Serial Conversion Option (SCO)

LOD 12/31/10
248

Adds CAC Reader Support


This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM Global Console Manager


Serial port Power switch (ARI) Server connection ports

Network connection
249

KVM ports for console

Local USB for Keyboard, Mouse, USB CDROM, USB Mass Storage
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Up to 16 servers off a single port KCO & UCO Support Chaining Chained via CAT5, 5e, 6 1754D1X chain up to 256 Servers 1754D2X chain up to 512 Servers Lowers acquisition/cost per port

UCO & KCO Support Chaining

250

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM GCM2/4 Mtodos de conexes de servidores

Directly

All UTP (CAT5, 5e, 6) Via Daisy-Chain


251

Via Secondary Switch


2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

Planejar instalaes / Consideraes eltricas BC Parte 2 Cabos de Power BladeCenter H Cuidados !

252

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Energia do BladeCenter IBM Simples, fcil, descomplicado..

IBM BladeCenter

Fonte interna Simples. Eficiente. Sem cabos. Descomplicado.

HP BladeSystem 48V external

Despoluido.

Standard AC input

253

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Planejar instalaes / Consideraes eltricas BC

254

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Conectores usados em Mqs. Rack e BladeCenter

255

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Conectores usados em PDUs

256

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Conectores usados em PDUs

257

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Planejar instalaes / Consideraes eltricas BC

258

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

259

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Planejar instalaes / Consideraes eltricas BC

260

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Planejar instalaes / Consideraes eltricas BC

261

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

262

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Suporte a instalaes e Ps-Instalaes BC

263

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Power Distribution Units (PDU)

264

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

E agora ???

265

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Technologia IBM
Eliminando Hot Spots no Datacenter
Air Conditioning Units

Hot Spot Area


Rear Door Heat Exchanger
266

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Porta traseira com refrigerao a gua!


Air Conditioning Units

Rear Door Heat Exchanger


267

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Soluo BladeCenter Boot Disk System


Management Station
Ethernet Fabric
High Speed Switch Bay High Speed Switch Bay EN BDG Blower SAS AMM

Default: 192.168.70.125 Default: 192.168.70.125


SAS EN Power Blower Power AMM

Default: 192.168.70.125 Default: 192.168.70.125

Default: 192.168.128.101
EN BDG Blower SAS AMM SAS EN Power Blower Power AMM

Default: 192.168.128.102

High Speed Switch Bay High Speed Switch Bay

IBM BladeCenterE (or BladeCenterH)


Power / Cooling Power / Cooling

IBM BladeCenterH (or BladeCenterE)

IBM BladeCenter Boot Disk System

268

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Por que virtualizar sua infraestrutura?


Voc precisa inovar e ter a capacidade de disponibilizar novas aplicaes rapidamente mas voc limitado pelos problemas existentes em sua infraestrutura,
Grande quantidade de servidores fsicos custo desconhecido, problemas com espao fsico Baixas taxas de utilizao entre 5 e 10% em mdia para x86 Complexidade no gerenciamento custo crescendo mais rapidamente que a prpria aquisio de servidores

Consolidao e Virtualizao endeream estes problemas reduzem a complexidade e o custo de gerenciamento enquanto trazem flexibilidade, adaptabilidade e disponibilidade ao data center
This document is for IBM and IBM Business Partner use only

269

2012 IBM Corporation

IBM System x and BladeCenter

Otimizao de TI: vrias abordagens so possveis

Consolide vrios centros em poucos locais Reduza a complexidade da infra-estrutura Melhore o gerenciamento das instalaes Reduza necessidade de equipes Melhore a resilincia de negcios da empresa Gerencie melhor um nmero menor de fatores Melhore custos operacionais

Consolide vrios servidores, discos e fitas em um menor nmero de unidades fsicas, com espao e consumo de energia menores Reduza a complexidade e gerencie os sistemas

Integrao de Aplicaes Virtualizao


Migre vrias aplicaes para poucas imagens Use Tcnicas de SOA Simplifique o ambiente de TI Reduza os recursos para operar sistema Melhore monitorao e ajustes / tuning

Centralizao
270

Remova barreiras fsicas Aumente a utilizao do hardware, seja servidor, Consolidao disco ou fita Fsica Aloque recursos em metas agressivas, porm abaixo do limite fsico Reduza custos de This document is for IBM and IBM Business Partner use only licenciamento de SW

2012 IBM Corporation

IBM System x and BladeCenter

Reduza custos com aumento de performance


Eficincia em consolidao ( 1 x3650M3 20 x346)
Clientes podem reduzir consumo de energia e manter o volume de trabalho com o novo servidor x3650 M3:

2006
20 - x346 Server Procesador de 1 socket
20:1 Consolidacin (1)

50% de reduo de custos anuais em energia 12x mais performance por servidor(1) 93% reduo de espao fsico

2011
1 - x3650 M3 Server Procesadores six core

(1) Based on IBM Alinean Tool Results


271

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

O que virtualizao?

Transformar um grande e nico recurso em recursos menores e independentes.

- ou -

Recursos muito menores trabalhando como um s.

A representao lgica dos recursos livres das limitaes fsicas Crie vrios recursos virtuais dentro de um nico dispositivo fsico Alcance alm da caixa veja e gerencie vrios recursos virtuais como um s Mude e ajuste dinamicamente atravs da infraestrutura
272

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM e a virtualizao da infraestrutura de TI


A combinao da virtualizao de servidores e unidades de armazenamento faz sentido e se tornar requisito no data center, de uma forma ou de outra. Na verdade, o quo mais inerente a virtualizao se tornar, maior ser o contraste causado em comparao infraestrutura fsica por si s, que ter, por sua vez, sua ineficincia revelada de forma aparente.
-- Enterprise Strategy Group, January 2008

A virtualizao de servidores OU storage isoladamente apenas uma parte da resposta A IBM oferece solues para um plano de virtualizao completo

Virtualizao de servidores OU storage aprimoram apenas uma poro da infraestrutura de TI

273

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Ambiente x86 virtualizado Uma realidade em TI


Virtualizao na arquitetura x86 implementado apenas por software. O Hypervisor responsvel pela hospedagem e gerenciamento de todas as mquinas virtuais. Exemplos: VMware, Hyper V, Xen, pHype (thru HMC/IVM), etc.

Guest Applications

Guest Applications

Guest Applications

Guest Applications

Guest OS

Guest OS

Guest OS

Guest OS

Virtualized CPU, Memory, IO

Virtualized CPU, Memory, IO

Virtualized CPU, Memory, IO

Virtualized CPU, Memory, IO

VMM

VMM
Hypervisor

VMM

VMM

Physical Hardware (CPU, Memory, IO)

274

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Virtualizao muda tudo


Virtualization Objectives*
(Base: Imp/plan Virt.)
52% 53% 52% 53% 48% 51% 47% 48% 44% 32% 33% 31% 28% 26% 29% 14% 15% 20% 13% 16% 13% 13% 14% 13% 13% 10% 9%

Increase server utilization

Reduce costs

Quase de todos os clientes que virtualizam o fazem para simplificar a infraestrutura de TI e administao Isto no pode acontecer sem o devido gerenciamento.

Simplify IT infrastructure & admin Enhance resilience & reliability Increase scalability of infrastructure Improve app performance

Automate IT operations Improve flexibility to business goals and cycles Accelerate App Development & deployment

1H07 4Q06 3Q06

IBM Systems Directions 1H07


275

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Virtualizao Alguns exemplos em TI


Sharing

Virtual Servers Hypervisor Physical Server


OS
Device Driver

Create multiple images of a resource within a physical resource


Virtual Memory - LPARs Virtual Machines Logical Channels

Emulation

OS
Device Driver

OS
Device Driver

Create functions and facilities which appear to be real although they do not exist within the physical resource
In-Memory Virtual Networks Hipersockets iSCSI Virtual Tape

OS
Device Driver

Virt. Ethernet LAN

Hypervisor Aggregation

Pool multiple separate distributed resources so they appear as a single resources from the user point of view
Clusters RAID Virtual Disks SAN Volume Controller GPFS

Cluster

Remote Sharing and Aggregation

Grid Computing based on Web services (SOA)

Use services based on open interfaces and standards to share distributed resources that may be geographically remote
Enterprise-wide and cross-enterprise Web-based distributed grids for remote job processing, resource scavenging, instrumentation, and data.
276

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Ambiente virtualizado, ideal com High-End IBM

2P 32 GB Quad 8 Core
x3650 2.67GHz QC w/32GB Server cost = $22,572(1) + VMware License Number of VMs (Zone 2) ranges from 15-22(3) Recommend 18 VMs(3) BTUs 1497(2) Watts at idle 312(2) Watts at measured439(2)
Cost/VM $1,562(1) BTU/VM 83.7(2) Watts at idle/VM17(2) Watts at meas/VM24(2)
Notes (1) Pricing based for example (2) BTU and watts provided by IBM, measured by IBM in lab environment (3) Number of VMs based on IBM Virtualization Sizing Guide, publish date 9/5/07

4P 64GB Quad 16 Core


x3850M2 2.93GHz QC w/64GB Server cost = $52,655(1) + VMware License Number of VMs (Zone 2) ranges from 29-58(3) Recommend 50 VMs(3) over 2X VMs BTUs 2158(2) Watts at idle 455(3) Watts at measured 633(3)
Cost/VM $1,250(1) BTU/VM43.0(2) Watts at idle/VM9.1(2) Watts at meas/VM12.62)

Cost per VM is less on the 4P platform BTU per VM is less on the 4P platform Watts per VM is less on the 4P platform

277

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Cloud Computing
Banking
Virtualization Energy Efficiency

Asset Management

Service Management

Business Resiliency

Information Infrastructure

Security

Flexible Delivery Options

Workload Optimization

IT Por definio Cloud Computing um ambiente de hardware distribudo que oferece mais performance, melhor aproveitamento e menor consumo de energia. Retail
278

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Cloud Computing Atualidade em TI Valor IBM para seus clientes -

Entregar Cloud Computing e Simplificao de TI a nossos clientes, integrando o que h de melhor na IBM atual e futuramente em termos de produtos para simplificar a distribuio e o gerenciamento de seus workloads, garantindo

Escalabilidade, Disponibilidade e Performance.

Windows Servers

Virtual Servers, Windows Server Storage, Networks

Firewalls, Unix
Servers Routers

Unix Server
Switches

Networks

Pools of Virtualized Resources

Management

Servers Storage Linux Server


Linux Servers Storage

Servers Storage Networks

Servio

Complexo

Consolidao Fsica

Virtualizao

Conjunto

Cloud (nuvem)

279

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

O que Cloud Computing ?

National Institute of Standards and Technology


Definio de Cloud Computing: "Cloud computing um modelo conveniente para permitir acesso rede sob demanda para um conjunto compartilhado de recursos de computao configurvel ..... que podem ser rapidamente provisionados e atualizados com o mnimo esforo de gesto ou a interao de um prestador de servio. Este modelo de nuvem permite disponibilidade e composto por cinco caractersticas essenciais, trs modelos de servio, e quatro modelos de implantao. " Caractersticas essenciais: On-demand self-service Broad network access Resource pooling Rapid elasticity Measured Service (flexible pricing)
280

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Para melhoria das cargas de trabalho em TI e rentabilidade do negcio, a virtualizao, padronizao e a automao tm que ser somadas.

VIRTUALIZATION

STANDARDIZATION

AUTOMATION

Cost

Flexibility

Pesquisa do IDC com CIOs, apontou que mais de 50% dos participantes disseram que o corte de custos o principal motivo da deciso de contratar servios de computao em nuvem.

281

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

O que diferente com cloud computing ?


Without cloud computing With cloud computing Virtualized resources Automated deployment of IT resources Standardized services Location independent Rapid scalability Self-service

Software Hardware Storage Networking

Software Hardware Storage Networking Software Hardware Storage Networking

282

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

6 principais vantagens do Cloud Computing

1. Possibilidade de utilizar aplicaes da internet, sem que estejam instaladas no computador do usurio. 2. Permite acesso a diversos aplicativos independente do seu sistema operacional ou de hardware. 3. Backup, controle de segurana, manuteno, entre outros, so de responsabilidade da empresa fornecedora do servio. 4. Reduo de custos com infraestrutura. No modelo tradicional so altos os custos de energia, pessoal e hardware e o espao nos data centers limitado. 5. Facilidade em compartilhar dados, j que todos os usurios acessam as aplicaes e os dados da nuvem internet. 6. Simplifica muito as operaes ao usurio.

283

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Tipos de cloud computing

284

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM CloudBurst integrada de fbrica


Storage and Network Virtualization
Improve storage utilization Enable multi-tenancy support

Monitoring
Monitor both physical and virtual server environments

Usage and Accounting


Provide metering and accounting for cloud services Enable integration to billing systems if needed

IBM Cloudburst
Built for Purpose Cloud Solution

High Availability
Redundancy built in for high availability

Platform & Virtualization Management


Enhanced management of the virtual environment

Server, Storage, Network HW Service Automation


Orchestration of Cloud operations Integration point for service mgmt capabilities Service catalog and templates Automated provisioning of virtual systems Preinstalled and configured on IBM hardware

Energy Management
Energy management of the hardware infrastructure

285

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM CloudBurst Configurao & Oferta com System X

Qlogic 20 Port 8Gb SAN Switch 3550 M3 Management Server BladeCenter H Cloud Infrastructure HS22V Cloud Compute Servers Intel Xeon 5660 2.8 GHz 2P (12 cores) with 72 GB memory

HS22V Cloud Management Server Intel Xeon 5660 2.8 GHz 2P (12 cores) with 72 GB memory

BNT 10Gb Virtual Fabric Switch DS3400 & EXP3000


286

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

CloudBurst 2.1 Hardware Configurao/Opes


All Hardware Configurations include PDUs, Keyboard & Monitor, Cables
Small Around $300K US List*
One 42U Rack One BladeCenter Chassis One 3550M3 Mgmt Server Four HS22V Blades 1 cloud management, 3 compute capacity Redundant 10G Ethernet Networking Redundant 1G Ethernet Network for out of band management Redundant 8G FC Network One DS3400 - 2 Controllers each Storage Capacity = 12 600GB SAS (7.2TB raw)

Medium Around $600K US List*


One 42U Rack One BladeCenter Chassis One 3550M3 Mgmt Server 5 to 14 HS22V Blades 1 cloud management, 4 to 13 compute capacity, optional use of 1 blade for HA Redundant 10G Ethernet Networking Redundant 1G Ethernet Network for out of band management Redundant 8G FC Network One DS3400 - 2 Controllers each Up to 3 EXP3000 Storage Capacity = 24 48 600GB SAS (14.4 28.8TB raw)

Large Around $1.13M US List*


One 42U Rack Two BladeCenter Chassis One 3550M3 Mgmt Server 15 to 28 HS22V Blades 1 cloud management, 14 to 27 compute capacity, optional use of 1 blade for HA Redundant 10G Ethernet Networking Redundant 1G Ethernet Network for out of band management Redundant 8G FC Network Includes TOR 8G FC switch Two DS3400 - 2 Controllers each Up to 6 EXP3000 Storage Capacity = 48 96 600GB SAS (36 57.6TB raw)

Supports up to 100 VMs** *Indicative price only, not to be quoted

Supports up to 460 VMs**

Supports up to 960 VMs**

** Based on IBM internal estimates of standard CloudBurst 2.1 blade HS22V with Intel Xeon 5660 2.8 GHz processors and 72GB memory Each blade can support up to 36 VMs of 4GB size

IBM System Storage SAN Volume Controller is an option that can be added via on site services A larger configuration (56 blades) is expected to be available in 4Q
287

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Arquitetura IBM CloudBurst

SERVICE MANAGEMENT
End-User Access, Reservations & Management

PLATFORM & VIRTUALIZATION MANAGEMENT


IBM Director 6.1 .0 BOFM IBM Storage Mgr Virtual Center 2.5

ToolsCenter

Provisioning

Monitoring

Middleware & Security SUSE 10 SP2 & NFS VMWare ESXi 3.5 U4 Hypervisor

Windows 2003 R2 Enterprise 3650 M2 Server

288

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

SQL Server

IBM System x and BladeCenter

System X Cloudburst 2.1 Configuration Sizes


U 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
12 3 4 5 6 7 8 91 01 11 21 31 4
0

Main 3U PANEL

No.

U 42 41 40 39 38 37 36 35 34

Main 3U PANEL

No.

3U PANEL

3U PANEL

3U PANEL

3U PANEL

A F R

3U PANEL

B R F

3U PANEL

3U PANEL DS3400 1U GB Ethernet Sw 1U GB Ethernet Sw


1U Kbd. Mon.

x3550M3 Mgt Node C F R 3U PANEL D R F

33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

A F R

3U PANEL EXP3000 EXP3000 EXP3000 DS3400 1U GB Ethernet Sw 1U GB Ethernet Sw


1U Kbd. Mon.

B R F

x3550M3 Mgt Node C F R 3U PANEL D R F

3U PANEL

3U PANEL

3U PANEL Blade Center Comp.


Mgt PS1 Mgt PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

3U PANEL Blade Center Comp.


Mgt PS1 Mgt PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

12 3 4 5 6 7 8 91 01 11 21 31 4

U 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Main 1U 24port SAN SW 1U 24port SAN SW FE PDU FE PDU EXP3000 EXP3000 EXP3000

A F R

DS3400 EXP3000 EXP3000 EXP3000

B R F

DS3400 1U GB Ethernet Sw 1U GB Ethernet Sw


1U Kbd. Mon.

x3550M3 Mgt Node Blade Center Comp. C F R


Mgt Mgt PS1 PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

D R F

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Blade Center Comp.


Mgt Mgt PS1 PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

U 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Main 3U PANEL 1U PANEL EXP3000 EXP3000 EXP3000

A F R

DS3400 EXP3000 EXP3000 EXP3000

DS3400 1U 10G Ethernet 1U 10G Ethernet FE PDU FE PDU Blade Center Comp.
Mgt Mgt PS1 PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

C F R

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Blade Center Comp.


Mgt Mgt PS1 PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

No. U 42 41 40 39 38 37 36 35 34 33 B 32 31 R F 30 29 28 27 26 25 24 23 22 21 20 19 18 17 D 16 R F 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 FE PDU FE PDU

Main 1U 24port SAN SW 1U 24port SAN SW FE PDU FE PDU EXP3000 EXP3000 EXP3000

No.

A F R

DS3400 EXP3000 EXP3000 EXP3000

B R F

FE PDU

FE PDU

FE PDU

FE PDU

DS3400 1U GB Ethernet Sw 1U GB Ethernet Sw


1U Kbd. Mon.

x3550M3 Mgt Node Blade Center Comp. C F R


Mgt Mgt PS1 PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

D R F

BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer

BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer

1 2 3 4 5 6 7 8 9 10 11 12 13 14

FE PDU

BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer

FE PDU

FE PDU

FE PDU

Blade Center Comp.


Mgt Mgt PS1 PS2 Fan 1 Fan 2 PS3 GbE PS4 GbE

BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer

BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Small
4 Blades 289

Medium
5-14 Blades

Large
15-28 Blades

X-Large
29-56 Blades 2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer BladeServer

FE PDU

FE PDU

IBM System x and BladeCenter

Atravs do Smarter Computing, uma empresa pode reverter o crculo vicioso e dobrar sua capacidade de servios de TI com o mesmo oramento
Reduzir custos para aumentar a TI Eficiente e Inovadora para economia de TI Maior Economia Custo de aquisio de servidores em at 56% Espao fsico em at 90% Consumo de energia em at 80% Cloud Produtividade do administrador em Sistemas at 20% Otimizados Reinvestir em inovao Entregar novos servios mais rapidamente Identificar novas tendncias mais rapidamente Criar novos mercados Utilizar recursos de TI mais efetivamente
290

Smarter Computing

Big Data
2012 IBM Corporation

This document is for IBM and IBM Business Partner use only

IBM System x and BladeCenter

IBM Systems Software enderea as prioridades dos clientes...

Virtualizao

Gerenciamento

Disponibilidade

Como eu maximizo a utilizao dos recursos?

Como eu meo a sade da TI?

Como eu gerencio os riscos e evito paradas?

A Fundao para Cloud

O Pilar dos Sistemas Otimizados

A Rede de Segurana para o Big Data

Systems Software a Fora Integradora no Smarter Computing


291

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Ajudando nossos clientes a transformar sua TI:


Systems Software entrega uma proposio de valor convincente

1. Melhora a utilizao, diminui os custos, e reduz o consumo de energia 2. Adiciona escalabilidade sem adicionar complexidade 3. Ajusta dinamicamente os recursos de acordo com as necessidades de negcios

1. Centraliza e integra o gerenciamento de servidores, armazenamento de dados e rede 2. Melhora a eficincia de TI para entregar melhores servio e Time to Market 3. Reduz os custos administrativos dos ambientes de TI que crescem rapidamente

1. Resilincia sem paradas nem riscos 2. Reduz o tempo para salvar, proteger, e restaurar os dados 3. Escalabilidade sem comprometer

292

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Produtos lderes entregam eficincia aos data centers

Virtualizao

Gerenciamento

Disponibilidade

z/VM VMControl Starter kit for Cloud SVC & Storwize v7000 Network Control PowerVM

GPFS Systems Director Active Energy Manager Tivoli Storage Productivity Center Storage Control IBM SoNAS PowerHA Real-time Compression ProtecTIER XIV

293

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM STG Systems Software


Recursos para BPs
Home page de Systems Software: Contm descritivos sumarizados por pilar (Virtualizao, Gerenciamento e Disponibilidade), plataforma ou Sistema Operacional. Esto disponveis vrios links para informaes complementares que podem ser utilizadas nos projetos, incluindo uma pgina rica em recursos (SSW Resources). Home page de Systems Software no PartnerWorld: IBM Business Partners tm uma nova home page no site PartnerWorld, onde podem encontrar links teis para materiais sobre os produtos de Systems Software, treinamentos, tudo em um nico lugar, entre outros recursos valiosos. Salve esta pgina em seus Bookmarks hoje! KYI Virtualization Module: Este mdulo faz parte do programa de recompensas Know Your IBM Sell & Earn, complementando a participao de Systems Software no programa e ajudando os Business Partners com uma viso geral sobre virtualizao, uma descrio dos benefcios das principais ofertas de virtualizao e gerenciamento de sistemas da IBM, como responder aos principais desafios dos clientes e atend-los pelas diversas fases da virtualizao, a proposio de valor, diferenciais sobre a concorrncia, e muito mais! Systems Software Overview: Systems Software uma rea crtica de negcios para a IBM, nossos Parceiros e clientes. Esta sesso GRTIS de vendas explica o que Systems Software e seu valor para os clientes e a IBM. Adicionalmente, ela ajuda os vendedores a compreender e aplicar a estratgia de Systems Software para as diversas situaes enquanto enderea as necessidades dos clientes demonstrando um significativo valor de negcios atravs de solues robustas. Systems Software Sales Simulator: Aprenda como vender Systems Software junto com suas propostas de hardware e aumentar suas chances de vencer em 40%! Faa o teste GRTIS do Systems Software Sales Simulator e desenvolva e pratique seus conhecimentos de venda consultiva. Este jogo divertido uma oportunidade de negociar com um cliente fictcio via 3 cenrios para avanar uma oportunidade de Systems Software. Seu sucesso depende da sua habilidade em realmente escutar o cliente, pois a reao dele ir determinar sua habilidade em This document is for IBM and IBM Business Partner use only 2012 IBM Corporation permanecer no jogo!"

294

IBM System x and BladeCenter

IBM Systems Director 6 Para System x and BladeCenter


Gerenciamento de sistemas fcil e eficiente Gerenciamento centralizado Gerenciamento end-to-end

295

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Normas, regras, padres: WWW.DMTF.ORG

296

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM Systems Director 6 para monitorar e controlar seus servidores sem custos adicionais IBM Systems Director como a base de gerenciamento de seus servidores
Descubra e tenha um inventrio do que voc tem Monitore e configure alertas e avisos Otimize o uso dos seus recursos e minimize problemas Processo simplificado de instalao, atualizao e deployment Integrao com softwares enterprise de gerenciamento de servios

Monitoramento e alertas com limites definidos para CPU, memria, file systems Garanta que Hardware Management Console (HMC) e Virtual I/O Server (VIOS) esto operacionais Automatize aes baseadas em eventos especficos e alertas crticos para reduzir o tempo de manuteno e otimizar a sua equipe de TI

297

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM Systems Director 6 para gerenciamento integrado das plataformas de hardware

Simplifique o gerenciamento das plataformas de hardware, sejam servidores, storages, PoS, estaes de trabalho Gerenciamento de recursos fsicos e virtuais Interface grfica intuitiva Integrao com outros softwares de gerenciamento

298

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Foco em Descoberta e Inventrio

Descubra seus sistemas Descoberta atravs de faixa de IP Descoberta atravs de SLP e SNMP Entenda os seus ativos Relatrio dos equipamentos de um ativo Verso e detalhes dos itens de um ativo

299

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Foco em Atualizaes

Atualize seu software Mantenha sistemas operacionais atualizados Atualize HMC Atualize seu hardware Atualizaes de firmware Atualizaes de drivers

300

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Foco em status, automao e sade dos sistems.

Sumrio de health Sistemas favoritos Monitores crticos Grupos de grficos miniatura Monitoramento Monitore recursos crticos Limites crticos Eventos Planos de automao Notificao Rode comandos Ative tarefas

301

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM Systems Director topology IBM System Director Server


Application Logic Database

Management Console(s)
Web Interface

IBM Systems Director Agent


Sistemas gerenciados
(Servers, Desktops, Laptops, SNMP devices, CIM devices)

Arquitetura 3-tiers: console, servidor, agentes Milhares de recursos gerenciados Integrao com outras ferramentas
Tivoli, Computer Associates, Hewlett Packard, Microsoft
302

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter Other Systems Management Software


$$ $$

Enterprise Service Management

$$

$$ $$

$$

Image Management

Service and Support Manager

Additional Plug-Ins

Additional Plug-Ins

Additional Plug-Ins

Additional Plug-Ins

Additional Plug-Ins

Active Energy Manager

TPMfOSD

Advanced Managers & Priced Plug-Ins

BOFM

Automation Status Virtualization Discovery

Update Remote Access Core Director Services Configuration

System x & Blade Center System z Power Systems Storage Configuration

Base Systems Director Managers & HW Platform Managers Resource Management Managed virtual and physical environments

Hardware IBM and nonIBM hardware


303

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

O que IBM Systems Director pode gerenciar?

Blade and Modular resources that can be managed: BladeCenter, Blade servers (x, Power, Cell), I/O modules, Modular servers VMware ESX, VMware 3i, MSVS, Xen Windows, Linux, Netware POWER System resources that can be managed: HMC, IVM, Virtual I/O Server, System i/p Servers (FSP) AIX, POWER Linux, IBM i Mainframe Systems resources that can be managed: Linux on zSeries z/VM HP, Dell, and other x86 servers SNMP-based devices Network, storage, power distribution units, etc. CIM-based devices CIM = Common Information Model Storage resources that can be managed: LSI (IRC), DS3000, DS4000, DS6000, RSSM SAS Switch (NSSM, RSSM), Brocade FC Switch, Qlogic FC Switch
This document is for IBM and IBM Business Partner use only

304 304

2012 IBM Corporation

IBM System x and BladeCenter

IBM Systems Director tiered agent support Common Agent


Permite ver e reportar o status do sistema
Autenticao nica e gerenciamento de credencial utilizando um nico agente Porta nica, compartilhada, de gerenciamento (firewall friendly) Maior disponibilidade utilizando um sistema watchdog para reiniciar o agente, se necessrio

Agente compartilhado entre IBM Systems e produtos Tivoli, como Tivoli Provisioning Manager, reduz a quantidade de agentes necessrios, suporta compartilhamento de credenciais, e outras informaes como inventrio e outros servios comuns Substitui os agentes nvel 2 antigos durante a integrao desta nova plataforma

Platform Agent
Prov mais funes de agentes comuns que so usadas para comunicao e administrao dos sistemas gerenciados, incluindo alertas de hardware e informaes sobre o sistema Interoperabilidade otimizada utilizando padres abertos ao invs de tecnologias proprietrias Atualizaes de firmware, drivers e remote deployment

Agent-less Management
Sistema Agent-less so perfeitos para ambientes que no necessitam funes avanadas e que s precisem de atualizaes de firmware, drivers e remote deployment.

305

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

IBM Systems Director 6: Plug-Ins para otimizar o gerenciamento


Permitindo gerenciar seus sistemas de maneira inovadora
Virtual Server Image Manager: automatize clonagen, capturao, customizao e deployment de imagens de sistemas virtuais, simplificando radicalmente a instalao de novos sistemas Active Energy Manager
Monitore e analise o uso de energia de seus servidores e PDUs Controle o estado dos sistemas e seus modos de operao Prov agregao de dados sobre o uso de energia do servidor para o ITM

Advanced Managers
. . . . . .

Systems Director Base and HW Platform Managers

Energy

Image

..

. .

Service and Support Manager identifica e reporta problemas relacionados ao hardware, permitindo que o suporte IBM seja pro-ativo garantindo maior performance do sistema e maior disponbilidade BladeCenter Open Fabric Manager-Advanced upgrade permite definir e redefinir os endereos de MAC e WWN usados pelas portas de I/O nas blades dos chassis Bladecenter Workload Partition Manager: permite manter os sistemas com tempos de resposta consistentes ajustando os recursos conforme picos de utilizao IBM Tivoli Provisioning Manager for OSD Deployment uma ferramenta desenhada para provisionar sistemas operacionais atravs de uma biblioteca de imagens de discos para qualquer sistema na rede

Alguns Plug-Ins no esto inclusos no IBM Systems Director bsico


306

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Integrao com outros sistemas Systems Director garante integrao completa com pacotes de gerenciamento high-level
Tivoli Enterprise
TEC 3.8 & 3.9 ITM 5.1.x Configuration Manager 4.2.x Software Distribution Provisioning Manager Inventory Security Operations Manager Distributed Monitoring

Tivoli NetView 7.1.x (Windows and Linux) Tivoli Netcool (Netcool/Omnibus, Netcool/Precision IP (via SNMP), Netcool/Monitoring, Netcool/ISM, Netcool/AEM (via SNMP) CA Unicenter NSM 3.1 and R11 (Windows) HP OpenView NNM 7.0.1 and 7.5.1 (Windows and Linux) HP OpenView Operations for windows 7.5x (Windows) Microsoft Systems Management Server, Microsoft System Center Operations Manager, and Microsoft Operations Manager 2005
307

HP OpenView

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Active Energy Manager = Systems Director plug-in


Monitore, analise e gerencie componentes de energia tais como Systems x servers Bladecenter servers Systems p servers Systems z servers Systems Storage UPS e CRACs Smart PDU (PDU+ e High Density PDU+) Environment Probing Device

Reduza o consumo de energia do seu datacenter utilizando Power Capping nos servidores Systems x, Bladecenter e Systems Storage Modifique dinamicamente o consumo de energia utilizando o Power Saving nos servidores System p e System z
308

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Comunidade de Capacitao System x B2S

309

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Capacitao de canais Canais Brasil . COM - System x B2S

310

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

RECORDANDO 1) Qual ferramenta oficial de X para config ? 2) HS22, HS22V e HX5, podem ser ligadas n chassi ? 3) O que 25R5785 ? 4) 10 ou 8 baias de switch no BCH ? 5) O que significa DMTF ? 6) Qual altura em Us do chassis S? 7) CIOv pode estar em uma lmina instalada no BCE? 8) MAX5 para Blade, tem quantos slots de memria?

311

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Princpios para sempre estarmos aprendendo!


Muitas pessoas pensam que ter talento uma questo de sorte; poucas, no entanto, pensam que a sorte possa ser questo de talento.

Ningum vai bater mais forte do que a vida. No importa como voc bate e sim o quanto aguenta apanhar e continuar lutando; o quanto pode suportar e seguir em frente. assim que se ganha!.

Ser o melhor no apenas um slogan, um desafio e uma meta que buscamos, atravs do trabalho, do profissionalismo, da determinao e da conduta tica e responsvel em todas as nossas atividades. Ser o melhor sim, mas no a qualquer preo!.

H um momento especial que acontece na vida de toda pessoa, o momento para qual ela nasceu. Quando aproveitada, essa oportunidade extraordinria faz com que a pessoa cumpra sua misso uma misso para a qual somente ela tem as qualificaes necessrias. Nesse momento, a pessoa encontra a grandeza. Esse seu mais maravilhoso instante!.

Tenho certeza que nesse momento existem vrios parceiros vendendo por ns!.

312

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

IBM System x and BladeCenter

Gracias
Hebrew Russian Spanish

Grazie
Italian Arabic

jeffs@br.ibm.com

Thank You
English

Obrigado
Portuguese

Merci
French Traditional Chinese Japanese

Danke
German

Korean

Simplified Chinese

Thai

313

This document is for IBM and IBM Business Partner use only

2012 IBM Corporation

Das könnte Ihnen auch gefallen