GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

8. 8.1. ITEM 1. 1.1

PRESSURE SHAFT BUTTERFLY VALVE AND ACCESSORIES Guaranteed Technical Particulars DESIGNATION General Manufacturer/ Type designation Voith /Fouress /TBHydro /Hongcheng IS/DIN/Voith norms UNITS VALUE REMARKS

1.3 2. 2.1

Applicable standards Main data Maximum leakage from main valve when fully closed against maximum head of 50 m (with new seal) through service seal through maintenance seal Maximum leakage from bypass valve at mentioned head of 50 meters

L/min L/min L/min m

3 3 During detailed engg. During detailed engg.

2.2

Maximum head loss through the valve at a flow required for rated turbine output at rated net head for three machines Maximum torque required to close the valve with a flow corresponding to

2.3

rated turbine output at rated net head of 396.20 m for three machines Nm specified turbine overload output at rated net head of 396.20 m for three machines 2.4 Main dimensions of shut-off valve inside diameter length of valve body (excluding extensions) mm mm Nm

During detailed engg. During detailed engg.

2750 During detailed engg.

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

ITEM

DESIGNATION

UNITS

VALUE During detailed engg. 2

REMARKS

maximum distance from horizontal mm centreline of valve to lowest portion of assembly 2.5 Lowest factor of safety (referred to design yeild stress) for any hydraulically loaded part of the valve Valve operating oil pressure minimum maximum 2.7 Inlet valve compressed air system Manufacturer Type/designation Number of units Nominal discharge pressure Max. pressure for operation of safety device Unit discharge rate 2.8 Inlet valve compressed air receiver Manufacturer Type/designation Number of receivers Design pressure Operating pressure Volume Nos. Kg/cm2 Kg/cm2 m3 Nos. Kg/cm2 Kg/cm2 m3/s Kg/cm2 Kg/cm2 -

For Operating load condition.

2.6

~80 ~120 Not Applicable

Not Applicable

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

8.2. ITEM 1. 1.1 1.2 1.3 2. 2.1 2.2 2.3

Informative data DESIGNATION Servomotor Make Nominal design oil pressure Active volume Oil pressure unit (OPU) Number of main oil pumps Type of oil pumps Oil pump discharge capacity at pressure Nos. L/min Kg/cm2 2 Fixed displacement ~13 120 Kg/cm2 m3 Reputed 120 13.7 UNITS VALUE REMARKS

3. 3.1 3.2 3.3 4. 4.1 4.2 5. 5.1

Pressurised accumulator tank Total oil volume Design pressure L Kg/cm2 ~100 120 During detail engg

Dimension of tank(Height & diameter) mmm m Sump tank Total oil volume Size of the sump(Lx W x Depth) Inlet valve compressor unit Compressor motor rating L mm

~200 During detail engg Not applicable

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

ITEM

DESIGNATION Power Voltage Frequency

UNITS KW V Hz kg

VALUE

REMARKS

5.2 5.3

Weight of complete unit Overall dimension Length Width Height

mm mm mm Not applicable Kg.

6. 6.1 6.2

Inlet valve compressed air receiver Weight Dimensions Diameter Overall height mm mm Sec

7.

Guaranteed closing time of butterfly valve at rated load and rated head of 78.25 m Guaranteed closing time of butterfly valve at overload of (110%) and maximum head of 91.6 m Guaranteed maximum opening time at rated head Guaranteed maximum opening time at maximum head

During detailed engg

Sec

Sec

Sec kg mm mm 38000 4890 x 3440 x 1100

8 9.

Weight of complete shut off valve Dimensions (complete shut off valve)

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

8.3.

Recommended additional spare parts List hereunder the spare parts, which are recommended by the Bidder for purchase in addition to the specified spare parts. The purchase of any or all of the recommended spare parts will be at the option of HPPCL. The prices for recommended additional spare parts for five (5) years shall therefore not be included in the bid prices.

ITEM 1. 2. 3.

DESCRIPTION No Recommended additional spare parts.

UNIT -

PRICE/ UNIT -

Note: Use additional sheet if required 8.4. Information to be supplied together with the bid At least the information listed hereunder shall be given by the Bidder. The Bidder may support advantages in his design of the delivery or special technical features of his offer by additional documents / descriptions 1. Indicate type of construction (cast steel or welded steel) for valve body and rotor [Reply] - Welded steel 2. Describe method of operation on closure of the valve (by oil pressure and counter weight) [Reply] - Refer Technical Description of Penstock BFV. Bid clause - 8.4.1. 3. Specify proposed type of by-pass valve. [Reply] - Refer Technical Description of Penstock BFV. 4. Describe method of operation of the automatic air inlet and vacuum release valve [Reply] - During Detail Engineering 5. Specify proposed type of service seal control valve. [Reply] - During Detail Engineering 6. Provide dimensional drawing with cross section showing the type of trunion seal, bearing, general arrangement of major valve parts and main dimensions [Reply] - During Detail Engineering 7. Provide schematic and block diagram of complete shut-off valve system [Reply] - Refer drg Hydraulic schematic-BFV control- Drg 2734-670003SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

Bid clause 8.4.2. and Technical Desciption - Mechanical Hydraulic Governor for BFV control -Bid clause 8.4.3 8. Indicate expected maximum dynamic and static loads on foundation for the most unfavourable conditions (opening/closure) [Reply] - During Detail Engineering 9. Provide information on field performance tests performed on a shut-off valve, which is similar to the proposed valve. Indicate at least the following: [Reply] - During Detail Engineering place of field test year of field test size of valve design pressure

10. Complete details of tools required for erection of Penstock Butterfly valve and its Accessories. [Reply] - During Detail Engineering

SAINJ HEP