Sie sind auf Seite 1von 5

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

3. 3.1. ITEM 1. 1.1

GOVERNING SYSTEM AND ACCESSORIES (DIGITAL TYPE) Guaranteed Technical Particulars DESIGNATION General Manufacturer/ Type designation Control unit Hydraulic unit Voith Hydro As per attached supplier list India IEC/Relevant standards NA Digital governor UNITS VALUE REMARKS

1.2 1.3 1.4

Place of manufacturer Applicable standards Capacity Main data

2. 2.1 2.2 2.3

Governor characteristics Description and method of operation Range of adjustment of permanent speed droop % Refer offer documentation 0 to 10 <0.02

Sensitivity of governor to respond to % minimum speed change of rated speed Range of adjustment of governor opening and closing time s

2.4

~10-30/10-30 secs ~2/2 secs

Nozzle opening/closing Deflector opening/closing

2.5 2.6 2.7

Speed dead band Dead band range Speed changer adjustable range(no load)
1

% Hz %

<0.01 0.04 90 to 110

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

ITEM 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16

DESIGNATION Power changer adjustable range

UNITS %

VALUE 0 to 100 ~2 Throttle During detail engg Hydraulic Yes, over Profibus Toothed disc Yes ~ 48

REMARKS

Time for deflectors to cut off the jets s from runner under full load Means for adjusting governor operating times Type of Regulator Cubicle Type of Actuator Compatibility with Data Acquisition & Control System Type of Generator (SSG) provided for governor Provision of emergency control Maximum dynamic pressure for kg/cm2 total load rejection of all four two (2) turbines working in parallel on 110 % load at maximum net head of 400.7 m 400.46 m Governor operating oil pressure minimum/maximum/rated Kg/cm2

Water pressure

2.17

~80/120 Directional poppet valve

2.18 2.19

Type of Emergency valve Minimum setting for Closing Opening s s

During detail engg During detail engg

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

3.2. ITEM 1. 1.1 1.2 1.3

Informative Data DESIGNATION Governor oil pumps Number of main oil pumps Type of oil pumps Unit governor oil pump discharge at pressure l/min Kg/cm2 Nos. 2 Variable displacement ~30 ~120 Diaphragm UNITS VALUE REMARKS

1.4 2. 2.1 2.2 2.3 2.4 2.5 2.6 2.7 3. 3.1 3.2 4.

Type of pressure switches Pressurised accumulator tank Total oil volume Design pressure Dimensions of tank(HXDIA.) Weight of each oil pressure vessel (with/without oil) Material No. of closing-opening-closing operation capable by stored oil only Normal volume of oil and air in pressurized tank Sump tank Total oil volume Size of sump ( LxWxdepth ) Instrumentation (Following details for each type of instrument to be furnished) L mm x mm x mm Nos. L L Kg/cm2 mmmm Kg

~250 120 During detail engg During detail engg Carbon steel 3 (Close-openclose) During detail engg.

~400 During detail engg

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

ITEM 4.1 4.2

DESIGNATION Make Details of sensor i) ii) Make & Type Principle of operation

UNITS

VALUE Hydac/Rexroth/Re puted Hydac/Barsdel/Re puted

REMARKS

During detail engg

4.3

Details of indicating Instrument/Controller I. Make & Type II. Analogue or Digital or LED III. Level switches for control IV. Auxiliary level switch for alarm V. Output for data acquisition system VI. Input voltage VII. Special cables Type No. of cores Size Screening Wika/Waree/Switz er/Hydac/Reputed. Dial/Analogue/Dig ital Float type NA Digital/Analogue During detail engg During detail engg

5. 5.1

Hydraulic oil Total quantity of oil required for complete system including servomotor Oil quantity l ~400/unit

5.2

~440/unit

With 10% margin

SAINJ HEP

GUARANTEED TECHNICAL PARTICULARS (SCHEDULE I)

3.3.

Recommended additional spare parts List hereunder the spare parts which are recommended by the Bidder for purchase in addition to the specified spare parts. The purchase of any or all of the recommended spare parts will be at the option of . The prices for recommended additional spare parts for five (5)years.

ITEM 1.

DESCRIPTION Operating panel for digital governor

UNIT No.

PRICE/ UNIT -

Note: Use additional sheet if required 3.4. Information to be supplied together with the bid At least the information listed hereunder shall be given by the Bidder. The Bidder may support advantages in his design or special technical features of his offer by additional documents / descriptions 1. Description of the governor, including schematic and block diagrams :- [Voith Reply] Refer technical description Bid clause 3.4.1, Hydraulic schematicTurbine Governor- Drg 2734-670001 - Bid clause 3.4.2 2. Drawing showing overall dimensions and general arrangement of equipment :[Voith Reply] Shall be submitted during detailed engineering. 3. Description and technical data of the programmable, numerical type control unit :- [Voith Reply] Please refer bid clause 15.4.3.10. 4. Applicable method and type of speed sensing equipment :- [Voith Reply] Please refer bid clause 15.4.3.1 5. Explanations of fail safe provisions according to Technical specification :[Voith Reply] Shall be submitted during detailed engineering 6. Details on the operating time adjustment for nozzle closing and opening (refer to Technical specification ) :- [Voith Reply] Shall be submitted during detailed engineering 7. Complete details of tools in accordance of Technical specification :- [Voith Reply] The Engineering Station (part of control system) shall be used as engineering tool for digital governor as well.