Beruflich Dokumente
Kultur Dokumente
BCM184J
SPECIFICATIONS & OPTIONS
SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001.
STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications can be considered on request. VOLTAGE REGULATORS AS440 AVR Standard With this self-excited system the main stator provides power, from an auxiliary winding, via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-ofphase paralleling. The AS440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access.
The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%.
NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range.
BCM184J
WINDING 71
CONTROL SYSTEM A.V.R. VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END 1 BEARING WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE 226 kg 79 kg 77.15 kg 0.2978 kgm 2 236 kg 97 x 57 x 96 (cm) 50 Hz TELEPHONE INTERFERENCE COOLING AIR VOLTAGE SERIES STAR VOLTAGE PARALLEL STAR VOLTAGE SERIES DELTA kVA BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS X'd DIR. AXIS TRANSIENT X''d DIR. AXIS SUBTRANSIENT Xq QUAD. AXIS REACTANCE X''q QUAD. AXIS SUBTRANSIENT XL LEAKAGE REACTANCE X2 NEGATIVE SEQUENCE X0 ZERO SEQUENCE T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 380/220 190/110 220/110 34.2 1.658 0.126 0.074 0.798 0.140 0.053 0.105 0.032 THF<2% 0.15 m/sec 318 cfm 400/231 200/115 230/115 36 1.575 0.119 0.070 0.758 0.133 0.050 0.099 0.030 415/240 208/120 240/120 34.2 1.390 0.105 0.062 0.669 0.117 0.044 0.088 0.027 440/254 220/127 254/127 N/A N/A N/A N/A N/A N/A N/A N/A N/A 416/240 208/120 240/120 40.4 1.789 0.136 0.079 0.861 0.151 0.057 0.011 0.034 AUXILLIARY WINDING AS440 1.0 % REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CLASS H IP23 0.8 DOUBLE LAYER CONCENTRIC TWO THIRDS 12 0.1372 Ohms PER PHASE AT 22C SERIES STAR CONNECTED 0.96 Ohms at 22C 8 Ohms at 22C 0.122 Ohms PER PHASE AT 22C BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min BALL. 6312 - 2RS. (ISO) BALL. 6306 - 2RS. (ISO) 2 BEARING 214 kg 79 kg 73.95 kg 0.2921 kgm 224 kg 97 x 57 x 96 (cm) 60 Hz TIF<50 0.19 m/sec 403 cfm 440/254 220/127 254/127 42.8 1.694 0.129 0.075 0.815 0.143 0.054 0.011 0.032 460/266 230/133 266/133 42.8 1.550 0.118 0.069 0.746 0.130 0.049 0.010 0.029 480/277 240/138 277/138 42.8 1.424 0.108 0.063 0.685 0.120 0.045 0.009 0.027
2
VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.025 s 0.016 s 0.59 s 0.0102 s 1/Xd
50 Hz
BCM184J
Winding 71 THREE PHASE EFFICIENCY CURVES
60 Hz
BCM184J
Winding 71 THREE PHASE EFFICIENCY CURVES
BCM184J
Winding 71 Locked Rotor Motor Starting Curve
50
Hz
30
346V 380V 400V 415V
25
20
PER CENT TRANSIENT VOLTAGE DIP
15
10
0 0 10 20 30 40 50
LOCKED ROTOR kVA
60
70
80
90
100
60
Hz
380V 416V 440V 460V 480V
30
25
PER CENT TRANSIENT VOLTAGE DIP
20
15
10
BCM184J
Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection.
50 Hz
10000
SYMMETRICAL ASYMMETRICAL
1000
CURRENT (Am ps)
100
10 0.001
0.01
0.1
TIME (secs)
10
60 Hz
10000
SYMMETRICAL ASYMMETRICAL
1000
CURRENT (Am ps)
100
10 0.001
0.01
0.1
TIME (secs)
10
Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit :
3-phase 2-phase L-L 1-phase L-N
60Hz
Voltage 416v 440v 460v 480v Factor X 1.00 X 1.07 X 1.12 X 1.18
Instantaneous x 1.00 x 0.87 x 1.30 Minimum x 1.00 x 1.80 x 3.20 Sustained x 1.00 x 1.50 x 2.50 Max. sustained duration 10 sec. 5 sec. 2 sec. All other times are unchanged Note 3 Curves are drawn for Star (Wye) connected machines. For other connection the following multipliers should be applied to current values as shown : Parallel Star = Curve current value X 2 Series Delta = Curve current value X 1.732
BCM184J
Winding 71 / 0.8 Power Factor RATINGS
Class - Temp Rise Cont. E - 65/50C 380 190 220 400 200 230 27.7 22.2 88.7 25.0 415 208 240 26.3 21.0 88.7 23.7 440 220 254 N/A N/A N/A N/A 380 190 220 27.3 21.8 88.6 24.7 Cont. B - 70/50C 400 200 230 28.7 23.0 88.6 25.9 415 208 240 27.3 21.8 88.7 24.6 440 220 254 N/A N/A N/A N/A 380 190 220 30.9 24.7 88.2 28.0 Cont. F - 90/50C 400 200 230 32.6 26.1 88.2 29.6 415 208 240 30.9 24.7 88.5 27.9 440 220 254 N/A N/A N/A N/A Cont. H - 110/50C 380 190 220 34.2 27.4 87.8 31.2 400 200 230 36.0 28.8 87.8 32.8 415 208 240 34.2 27.4 88.2 31.0 440 220 254 N/A N/A N/A N/A Series Star (V) Parallel Star (V) Series Delta (V)
50
Hz
60
Hz
DIMENSIONS
Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100
2006
TD_BCM184J.GB_10.06_04_GB