Welding Performance Qualification Record (WPQR) Welding Code: AASHTO/AWS D1.5 Company Name: Quinn Construction, Inc.

Company Address: 1321 77th Street, East Palmetto, Florida, 34221, USA Welders Name: David Turk Identification No: 5240 Type of welder: Welder Qualification Date: 5/4/13 Rev. 0

Welding Performance Qualification Record WPQR No. DT-5240 QC-11-SMAW-1 Welding Procedure Specification WPS No. QC-11-SMAW-1 BASE METALS USED Material Specification, Type or Grade: ASTM A 36 (T<= 3/4 in. [20 mm]) Welded to Material Specification, Type or Grade: ASTM A 36 (T<= 3/4 in. [20 mm]) Variables Welding Process Process Type Electrode (Single or Multiple) Current Type/Polarity Backing (Yes or No) Testing Position(s) and Qualified Welding Position(s): Groove Fillet Vertical Progression Plug or Slot Welds Base Metals Thickness in (mm): Groove Fillet Plug or Slot Welds Base Metals Diameter in (mm) (Pipe or Tube): Groove Fillet Filler Metal Specification (SFA) Filler Metal Classification (AWS Classified) Filler Metal F-Number Gas/Flux (SAW) Other Variable (coating type/thickness, etc.)

Plate Plate Actual Values Used SMAW Manual Single DCEP Yes n/a 3F Uphill

Pipe Pipe

Box Tube Box Tube

Sheet Sheet

Qualification Range SMAW Manual Single Yes n/a F, H, V Uphill

n/a 1/2 in. (12 mm), Fig. 5.21 n/a n/a Plate tested A5.1 E7018 4 n/a n/a Results

n/a Unlimited n/a n/a n/a Any AWS A5 Class Approved 4 (low-hydrogen only) n/a n/a

Visual Inspection of Completed Weld (D1.5, 6.26.1): Acceptable YES NO Guided Bend Test Type and Results (D1.5, 5.27.3): n/a Result and Comments: Fillet-Weld Test Results (D1.5, 5.27.4 and 5.27.6): Appearance: Acceptable Fillet Size in (mm): .385 Fracture Test Root Penetration: Acceptable Macroetch: Acceptable (Describe the location, nature, and size of any crack or tearing of the specimen.) Result and Comments: Resource id #9 Inspected by: Jonathan B. Stringer Test Number: G-0239-S Organization: Renegade Testing & Inspection Inc. Date: 5-4-2013 Alternative * Radiographic Test Results (D1.5, 5.26.1) : * In lieu of Guided Bend Test, except for GMAW-S Film Identification No. n/a Film interpreted by: n/a Organization: n/a Other information: n/a Results Remarks Film Identification No. Results Remarks

Test Number: n/a Date: n/a

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.5M/D1.5:2010, Bridge Welding Code. Manufacturer/ Contractor Authorized By: Welding Engineer Name: Jonathan B. Stringer Title: CWI - 10081211 Signature: Date: 5-4-13 Name: Title: Signature: Date:

Das könnte Ihnen auch gefallen