[1] Setting procedures
A special operating mode called the 25 Mode has been provided exclusively for specifying various settings. This mode allows data in memory IC to be rewritten. (1) Turn the main switch OFF. (2) While pressing the numerical keys 2 and 5 of the copy quantity setting button, turn the main switch ON. This will enable the 25 Mode. The 25 Mode is used exclusively to rewrite in memory and, therefore, does not support normal copy operations. (3) Using the copy quantity setting buttons, specify the address number of the data to be changed. (a) Press the P button. The address number will blink in the magnification indicator. (b) Enter the desired address number using the copy quantity setting buttons. The newly-entered address number will blink in the magnification indicator. (c) Press the P button. The blinking address number will be lit. (4) Rewrite the data currently stored in that address. (a) Enter the new data using the copy quantity setting buttons. The old data appears in the tens digit position of the copy quantity indicator and newly-entered data in the ones digit position. (b) Press the copy button. This will rewrite the data and change the copy quantity display to show the new data in the tens digit position. (5) Turn the main switch OFF to exit the 25 Mode.
6-1
DIAGNOSTICS
Item
Change details
Remarks
0, 1
*1
0, 1
*2
0-2 0, 1
*3
0-9
0: Max. 1: 1 2: 3 3: 5 4: 9 5: 10 6: 20 8: 50 9: 99 7: 30
A size mode selection Preferential paper size selection OHP interleave selection Auto Low power mode time setting
0, 1 0-5:USA 0, 1 1-5
0 2:USA 1 4
0: Normal 1: A size priority *4 0: Copy sheet 1: Blank sheet 1: 2 min. 2: 5 min. 3: 10 min. 4: 15 min. 5: 30 min.
0-8:Europe 1:Europe
0-3
0, 2 0, 5 0-9
0 5:USA
PM cycle specification
0 PM count 0-9 0 2 9 9 9 9
102
1
100
6-2
DIAGNOSTICS
Change details
Remarks
102 101 10
0
47 48
0-9 0-1
0 1
0 : Cancel 1-9 : Fault 0 : No auto reset 1 : Auto reset (Europe 90 sec., USA 120 sec.)
49
0-2
50 51
Double count specification for A3 copies Initial tray selection (when canceling APS)
0, 1 0-5
0 0
0: 1 count 1: 2 counts 0: Tray1 1: Tray2 2: Tray3 3: Tray4 4: Tray5 (Japan only) 5: Bypass tray
52 53 54 55 56 57
0, 8 0-1
0 0
0-9 0, 5
0 0 0 : Stop after the paper for the ongoing copy operation has exited. 5 : Stop immediately.
*6
58 59 60 61 62 63
Initial mode setting AMS mode priority selection Users bias shift selection Auto shut off timer setting
*7 *8
6-3
DIAGNOSTICS
Item 105 104 103 102 101 100 Priority of original/transfer sheet selection Whole image selection for bypass and universal trays 100 101 102 103 104 105 10
6
Change details
Remarks
Total count
*9 *10
107 Internal heater setting LCT paper size selection Switching the size selection/ casstte selection Copy (developing) count 0-9
0 : Internal heater not installed 1 : Internal heater install *11 0 : Size selection 1 : Cassette selection
0 0 0 0 0 0
100 Immediate stop mode setting (Caution code P25) KRDS host password setting KRDS time/date setting KRDS telephone number setting KRDS serial number setting KRDS memory switch setting 0, 1
0 : Enable 1 : Disable
6-4
DIAGNOSTICS
4 5
6 7
Data 0 1 2 3 4 5 6 7
6-5
DIAGNOSTICS
Setting 0 1
Mode All modes APS/AMS mode Other modes All modes ADF/ platen APS/AMS mode Other modes
Erasure control conditions Original mode Original mode Transfer sheet mode Transfer sheet mode Original mode
2 3
6-6
DIAGNOSTICS
47 MODE
[1] Setting the 47 Mode
This model is equipped with I/O check function as self-diagnostics that can be activated in 47 mode. It is possible to check the status of each sensor and to confirm and adjust each load.
1. Setting Procedures
(1) Turn the main switch OFF. (2) While pressing the numerical keys 4 and 7 of the copy quantity setting button, turn the main switch ON. This will enable the 47 Mode. Note: Both 4 and 7 keys must be held for more than 1 second after the main switch has been turned ON. (3) To check input signals (a) Using the copy quantity setting buttons, enter the code for the desired signal (sensors, etc.). For code, refer to the I/O check code list. (b) The magnification indicator displays the level of the signal being checked, Hi or Lo. Note: Hi or Lo indicate the signal level applied to the CB (control board). (4) To check output loads (a) Using the copy quantity setting buttons, enter the code for the desired output (load, etc.). For code, refer to the I/O check code list. (b) Press the copy button. This operation will activate a load or output a signal.
Copy button
Code
Description
Berore pressing Input Input signal level indication After pressing Output Output load operation/signal
(5) Press the stop/clear button to disable the output. (6) Turn the main switch OFF to cancel the 47 Mode.
6-7
DIAGNOSTICS
SSB1 SSB2 PFUB SSB121 SSB122 PS1 PS3 PS8 PS111 PS2 PS121 PS122 PS123
Paper size signal (Main Body/Upper) Paper size signal (Main Body /Lower) Paper size signal (DBU/Upper) Paper size signal (DBU/Middle, LCT) Paper size signal (DBU/Lower) Paper feed sensor (Upper) Pre-shutter sensor signal Exit detecting sensor signal Paper feed sensor (LCT) Paper feed sensor (Lower) Paper feed sensor (DBU/Upper)/ LCT upper limit sensor Paper feed sensor (DBU/Middle) Paper feed sensor (DBU/Lower)/ LCT sensor LCT connection signal Optics home position sensor signal Optics lens home position sensor signal
See*1
No No No
03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
Developing bias (dark-40V) Developing bias (normal-150V) Developing bias (light-280V) KRDS
SD1 SD2
Yes Yes
No No
Paper feed solenoid (Upper) Paper feed solenoid (Lower) Paper feed solenoid (DBU /Upper)/LCT motor Paper feed solenoid (DBU/Middle) Bypass feed solenoid Resist solenoid Paper feed solenoid (DBU/Lower/LCT)
PS4 PS7
No No No
SD5 M2
LCT1 solenoid Separation claw solenoid Optics drive motor Lens unit drive
PS112
Yes
No
SD6
Optics shutter
6-8
DIAGNOSTICS
Input signal source Sym- MultiName bol mode PS113 LCT1 paper conveyance sensor
C(K)
Yes
No
36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58
M1 M6 M4 C(T) L2
Main motor Drum drive motor Cooling fan motor Total counter Fixing heater lamp
OB CEL
PS304
ADF interlock Changeover section interlock ADF no paper sensor ADF paper size sensor ADF original exit sensor signal
ON No No No No
PS306
59 60 61 62 63 64 65 66 67 68 69 70 71 72
M301 M301
L detection control data (Upon completion of L detection adjustment) L detection control data (current) ADF motor rotation (CCW) ADF motor reverse rotation (CW)
ADF paper feed clutch ADF speed reduction exit solenoid ADF running mode
6-9
DIAGNOSTICS
Yes
No
73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99
AE
<Multi-mode list>
Code 15 Multi-mode No. 94 98 03 04 69 01 02 01 02 01 Description Service engineer call Setup call KRDS memory initialization Normal mode output Back-side mode Normal mode output Back-side mode ADF test mode
*2: Note-that all memorized data (include adjustment data)are reset when memory initial set is executed.
6-10