1) Choose a wrong sentence. "NIHON KOHDEN do not support component level repair because..." a): special tools and high degree of repair skills are required to fix the multi-layerd units or boards. b): quality of component level repair cannot be guaranteed without special tools and high level repair knowledge c): NIHON KOHDEN do not have enough budget and knowledge to repair. ( ) are playing the primary roles to control the overall functions of ECG-1250K/1350K. a) Thermal head and power board d) Power board and LCD unit b) LCD unit and inverter board e) Key board and main board c) Power board and main board f) Power board and speaker unit To access system test level 1, press and hold ( ) key while switching on the machine a) Auto/Manual d) Feed/Mark + Filter b) Feed/Mark e) Feed/Mark + Space c) Feed/Mark + Auto/Manual f) Copy/CAL + Auto/Manual Choose a right period to replace the battery pack. a) After 1 month operation d) After 1 day operation b) After 1 year operation e) After 1,000 hour operation c) After 10 year operation f) After 75,000 hour operation ( ) replacements are periodically required to maintain the quality of the ECG. a) Speaker, Key board, Inverter board b) Thermal head, Speaker, Battery pack c) Thermal head, Speaker, Battery pack, A/D converter d) LCD, Thermal head, Battery pack, Lithium battery e) LCD, Thermal head, Battery pack, Lithium battery, Feeding motor f) LCD, Thermal head, Battery pack, Lithium battery, Feeding motor, SpO2 probe g) LCD, Thermal head, Battery pack, Lithium battery, Feeding motor, Inverter board Points allocation 1 point

2)

1 point

3)

1 point

4)

1 point

5)

1 point

Cardiology - Defibrillator
1) To enter System Setup mode, press and hold ( ) key while turning the knob to ( a) Silence Alarm d) Monitor mode b) Alarm setting e) Setup mode c) ECG lead key f) AED mode ( ) list shows instrument operation history in chronological order ( ) report shows error history, check result of HV capacitor and battery ( ) report shows waveform, set energy, energy delivered and date/time a) Error d) Defibrillation b) Event e) 12L ECG c) Instrument f) Discharge It is recommended to replace the battery when it has been used for 1 year or more, or when the battery test result shows that the battery capacity has decreased under ( ) a) 85% c) 75% b) 80% d) 70% After battery is replaced with a new one, press ( date to the present date. a) Start c) Blank b) Menu d) Reset ) key to change the "battery replaced" )

2)

3)

4)

5)

Recording of waveforms is blurred. Choose the two most likely causes a) Recording paper is set with the wrong side facing up b) Specified recording paper is not used c) Recording unit door is not properly closed d) Thermal head is dirty e) Thermal head is too hot ( ) procedure must be performed when the delivered energy is out of specified range, when the delivered energy is checked against the delivery checker after replacing the HV capacitor and biphasic HV unit. a) Adjust ECG AD c) Adjust Battery AD b) Adjust HV AD d) Adjust Paddle Contact AD Case study The defibrillator fails to discharge after the discharge buttons are pressed simultaneously. Name and explain 3 possible causes in your preferred troubleshooting order

6)

7)

Points allocation 1 point

1 point

1 point

1 point

2 points

1 point

3 points