FC2040 Fire control panel

Series FS20 (MP1.1)

SintesoTM

z Compact, prefabricated, microprocessor-controlled fire control panel for the z z z z z z z z z z z z z z z z

connection of up to 504 addresses Fire control panel can be used as stand-alone version or networked Up to 16 stations such as fire control panels and fire terminals (in any arrangement) can be connected in one network Integrated emergency operation function Redundant network node, degrade operation according to EN 54 Fast Ethernet interface for heterogeneous network Integrated user-friendly operating unit Optional printer, key switch, LED indicators Slots for RS232, RS485 serial ports Emergency power supply for up to 72 h for emergency operating time Detection and automatic read-in (auto configuration) of all FDnet devices, providing immediate simple operation Processes signals from the SintesoTM detector series Time and situation-dependent change over of the detector parameters Floor repeater displays, operating panels and alarm devices in the detector loop (FDnet) Flexible programming of complex applications and controls Stored data can be uploaded via remote access Firmware download of all processor controlled control panel components

Building Technologies
Fire Safety & Security Products

System overview

2 Building Technologies Fire Safety & Security Products

Expansion to a complex fire detection system The high-performance FCnet/SAFEDLINK makes it possible to network up to 16 FC20xx fire control panels and FT2040 fire terminals together as required. The innovative redundant network nodes not only set new standards in terms of failsafe characteristics but also for high-speed data transfer. In addition, an Ethernet connection is available at each station. This Ethernet connection enables a maximum of 2 stations to be networked together (not EN 54-compliant).

For details about system networking, please refer to product data sheet 008955. Characteristics The FC2040 is a compact fire control panel with an integrated operating unit that can process signals from SintesoTM devices. The control panel can be used as a stand-alone unit or in a network. The control panel can be programmed with a user-friendly engineering tool (software) to create a system with great versatility. All detector lines are monitored for ground faults. Adaptation of the user text directly on the terminal or with the software engineering tool. Up to 1000 events can be stored according to various criteria. Automatic summer/winter time change. Connection of danger management systems via BACnet

3 Building Technologies Fire Safety & Security Products

Functional elements

Operating unit The following are located on the operating unit: CPU module and the electronics for the operating unit Ethernet connection Slots for RS232, RS485 modules and networking modules (SAFEDLINK) Space for 'Kaba' or 'nordic' key switch Space for event printer Peripheral board The following are located on the peripheral board: Connection terminals for FDnet loops, remote transmission (alarm, fault), horn outputs, programmable control inputs/outputs, monitored alarm and fault output, degrade supply, power supply Power supply 150 W, degrade supply The power supply supplies the hardware and charges the batteries The batteries supply the emergency power in case of power failure Housing A pivoting mounting panel can be installed on the housing backplane to allow installation of: 1 fire brigade periphery module Configuration An engineering tool permits the system to be adapted to specific customers' requirements. Application ranges The FC2040 is ideally suited for medium-sized applications, e.g. in industrial plant, regional banks, office complexes, etc. or when networked as part of much larger applications. Operation Each control panel has an integrated operating panel. Additionally the control unit can be operation for another separate FT2040 operator terminal. For details and further information, please refer to product data sheet 009386.

4 Building Technologies Fire Safety & Security Products

Overview of FC2040 fire control panels Housing (Comfort) FC2040-AE FC2040-AG


With 2 LED indicators (48 LED indicator groups) With 4 LED indicators (96 LED indicator groups)

FC2040-AA

4 loop With power supply (150 W) Battery capacity max. 26 Ah

4 loop With power supply (150 W) Battery capacity max. 26 Ah

4 loop With power supply (150 W) Battery capacity max. 26 Ah

Options FTO2001-A1
Event printer

FH2002-A1
Housing (Standard)

FH2003-A1
Housing (Comfort)

Can be installed in FC2040-AA FC2040-AE FC2040-AG RS232 module must be ordered separately

Empty housing for various applications e.g. for additional batteries, operating add-ons or event printer

Operating add-on FCM2006-A1 FCM2007-A1


(2xLED ind.) (4xLED ind.)

48 LED indicator groups For retrofitting

96 LED indicator groups For retrofitting

5 Building Technologies Fire Safety & Security Products

Configuration of FC2040 in housing (Comfort)

1 7

19

2 16 8 5

15 93 13 11 12 13

17 18

6 14 20 8 10 15
Basic equipment 1 Rear (Comfort) 2 Peripheral board (4-loop) 3 Power supply (SV 24V-150 W) 4 Mains terminals on DIN mounting rail TS35 5 Operating unit 6 Space for batteries Options 7 Relay module 8 Event printer Key switch (Kaba) 9 Key switch (nordic) 10 Mounting plate 11 RS485 module (isolated) 12 RS232 module (isolated) 13 Networking module (SAFEDLINK) Battery (12 V, 7 Ah, VDS, V0) 14 Battery (12 V, 12 Ah, VDS, V0) Battery (12 V, 26 Ah, VDS, V0) 15 Fire brigade periphery module 16 Door contact kit 17 Battery kit (9 Volt) 18 Lithium battery 9 V / 1 Ah 19 19" mounting kit 20 Power supply kit (150 W, B) Designation FHA2003-A1 FCI2004-A1 V24230-Z6-A2 FCM200x-xx Z3B171 FTO2001-A1 FTO2005-C1 FTO2006-B1 FHA2007-A1 FCA2002-A1 FCA2001-A1 FN2001-A1 FA2003-A1 FA2004-A1 FA2006-A1 FCI2001-D1 FCA2009-A1 FCA2010-F1 FHA2016-A1 FP2005-A1 Notes Nos. 1-5 > Basic equipment for each FC2040-xx (Comfort) Space for socket, relay modules, etc. Combined system operating panel and CPU, incl. cover 2 x 12 V / 7 26 Ah Relay for fire controls For event logging For operating access rights E.g. for fire brigade peripheral For peripheral devices with RS485 port For stations with RS232 port For networking various stations For emergency power supply For Germany (FBF, FSK, HM, isolating element, etc.) For monitoring the cover rd For 9 Volt battery (3 voltage source only for France) For FCA2010-F1 rd For the installation in 3 party housings For additional power supply 6 Building Technologies Fire Safety & Security Products

Technical data Mains voltage Power supply Operating voltage Operating current Battery capacity Battery monitoring Mains monitoring Connectable detector series Number of lines Loops or stub lines Number of addresses Integrated inputs/outputs Relay output Remote monitoring alarm / fault Monitored outputs Alarm / fault Horn Programmable inputs/outputs Operating unit Plug-in position for RS232, RS485 serial ports Plug-in position for networking modules Ethernet connection RJ45 Operating temperature Storage temperature Humidity (no condensation permitted) at T = 25 3 C at T = 40 2 C Dimensions (W x H x D) Color Housing Cover Protection category (IEC 60529) Approvals VdS LPCB 115/230 VAC 150 W 21 28.6 VDC max. 5 A 2 x 12 V, 26 Ah yes yes SintesoTM (FDnet) 4 8 max. 504

1 each 1 each 2 12 integrated 2 2 1 8 +42 C 20 +60 C 95 % rel. 93 % rel. 430 x 796 x 160 mm light grey, RAL 7035 pure white, RAL 9010 IP30 G206110 pending

7 Building Technologies Fire Safety & Security Products

Details for ordering Type FC2040-AA FC2040-AE FC2040-AG Options Z3B171 FTO2001-A1 FTO2005-C1 FTO2006-B1 FHA2007-A1 FCA2002-A1 FCA2001-A1 FN2001-A1 FCI2001-D1 FH2002-A1 FH2003-A1 FCM2006-A1 FCM2007-A1 FCA2009-A1 FCA2010-F1 FHA2016-A1 Additional power supply FP2003-A1 FP2004-A1 Fire control panels FP2005-A1 FA2003-A1 FA2004-A1 FA2006-A1 Part no A5Q00016100 A5Q00016852 A5Q00016854 4843830001 A5Q00010126 A5Q00017619 A5Q00010113 A5Q00010129 A5Q00010151 A5Q00009923 A5Q00005327 A5Q00012851 A5Q00013100 A5Q00018931 A5Q00009906 A5Q00021771 A5Q00021772 A5Q00012317 A5Q00012569 A5Q00004142 A5Q00020179 A5Q00016005 A5Q00020825 A5Q00018779 A5Q00019353 A5Q00019354 A5Q00019356 Designation Fire control panel (4-loop) Fire control panel (4-loop) Fire control panel (4-loop) Relay module 250 VAC / 10 A (1 relay) Event printer Replacement printer rolls (10 rolls) Key switch (Kaba) Key switch (nordic) Mounting plate RS485 module (isolated) RS232 module (isolated) Network module (SAFEDLINK) Fire brigade periphery module Housing (Standard) Housing (Comfort) Operating add-on (2xLED ind.) Operating add-on (4xLED ind.) Door contact kit Battery kit (9 Volt) (only France) Lithium battery 9 V / 1 Ah (for FCA2010-F1) 19" mounting kit Power supply kit (70 W) Power supply kit (150 W) for installation in empty housing Power supply kit (150 W) for the cascading Battery (12 V, 7 Ah, VDS, V0) Battery (12 V, 12 Ah, VDS, V0) Battery (12 V, 26 Ah, VDS, V0) Weight 18.280 kg 19.200 kg 21.080 kg 0.042 kg 0.250 kg 0.090 kg 0.100 kg 0,050 kg 0.800 kg 0.067 kg 0.068 kg 0.077 kg 0.482 kg 7.500 kg 15.000 kg 2.600 kg 2.800 kg 0.015 kg 0.100 kg 0.037 kg 3.000 kg 0.650 kg 1.366 kg 1.100 kg 2.450 kg 3,930 kg 7.572 kg

Batteries