Sie sind auf Seite 1von 77

Table of Contents

Pressure Vessel
construction and certification

Brazed Plate Heat Exchanger


design information and nomenclature

Shell and Tube Heat Exchanger Advantages


Condensers

Evaporators

Refrigerant Subcoolers

Chiller Builder Kits


Low-Side Chiller Builder

Liquid Receivers

Valve, Brackets and


Accessories
Warranty

Menu

Table of Contents

Condensers
Selecting the Right Condenser
HSE Shell-and-Tube

HSG Shell-and-Tube

SST Shell-and-Tube

CND-CB Copper-Brazed

CND-ACH Copper Brazed


Plate Heat Exchanger - R410A

CND-ACH2 Copper Brazed


Plate Heat Exchanger - R410A

Super Efficient - R410A

Plate Heat Exchanger

Ultra-Compact General Service

MSE Shell-and-Tube
Marine Service

SCH/SCS Coaxial

General Service

Horizontal Water-Cooled

High Efficiency

CND-AN AlfaNova
Fusion-Bonded

for high corrosion resistance

High Efficiency Dual Circuit

ELT Tube-in-Tube
Cleanable

For Shell-and-Tube stainless steel condensers (CA) used for high sulfur
content water and corrosive fluid applications, please contact customer
service for price and availability.
For Shell and tube vertical condensers (VSE), please contact customer
service for price and availability.

Custom Design Condenser


Specification Sheet

Replacement Condenser Gaskets and


Endplates Cross Reference Chart

Gasket IDs

Front Endplate IDs

Menu

Table of Contents

Evaporators
Selecting the Right Evaporator

Evaporator Sizing
TX/TXC Shell-and-Tube
Super Compact Serviceable

TXG Shell-and-Tube

Ultra Compact Serviceable

EVP-ACH2 Copper-Brazed
Plate Heat Exchanger R410A
High Efficiency Dual Circuit

Custom Design Evaporator


Specification Sheet

EVP-ACH Copper-Brazed

Plate Heat Exchanger R410A


High Efficiency

ERS/ERD Shell-and-Tube
OEM Replacement

Replacement Evaporator Gaskets


Cross Reference Chart

Menu

Table of Contents

Chiller Builder Kits


Chiller Builder Kit
with Shell-and-Tube

BHE Chiller Builder Kit

Menu

Table of Contents

Liquid Receivers
Design Features and Ratings
HR Horizontal Design

RBV Horizontal Design with


Brackets and Valves

UV Upright Receivers with


Valves

UR Upright Receivers

L Compact Vertical Receivers


with Valve and Fusible Plug

Menu

Table of Contents

Valves, Brackets and Accessories


Rotolock Valve

(4) Bolt Flanged Valve/


Indicator Components

Float Type Indicators


and Alarms

Rotolock Adapters

Safety Devices/Sight
Glass Indicators

Brackets - Universal and


Compressor Mounting

Menu

Commercial Refrigeration
Product Catalog Edition 4

Menu
Table of Contents
The information contained herein is correct at the time of issue but may be subject to change without prior notice.

Pressure Vessel construction and certification.................................................. 5


Brazed Plate Heat Exchanger design information and nomenclature ................ 6
Shell and Tube Heat Exchanger Advantages.................................................... 7
Condensers
Selecting the Right Condenser ..................................................................... 8-9
HSE

Shell-and-Tube-Super Efficient - R410A ........................... 10-11

HSG

Shell-and-Tube Horizontal Water-Cooled 1-Circuit .................12


Shell-and-Tube Horizontal Water-Cooled 2-Circuit .................13

SST

Shell-and-Tube-General Service....................................... 14-15

CND-CB

Copper-Brazed Plate Heat Exchanger


(ultra-compact) - General Service...........................................16

CND-ACH

Copper Brazed Plate Heat Exchanger


R410A - High Efficiency .........................................................17

CND-ACH2

Copper Brazed Plate Heat Exchanger


R410A - High Efficiency Dual Circuit ......................................18

MSE

Shell-and-Tube-Marine Service ........................................ 19-20

CND-AN

AlfaNova Fusion-bonded Heat Exchanger


for high corrosion resistance ..................................................21

ELT

Tube-in-Tube Cleanable .........................................................22

SCH/SCS

Coaxial ..................................................................................23

Custom Design Condenser Specification Sheet ..............................................24


Replacement Condenser Gaskets and
Endplates Cross Reference Chart ............................................................. 25-27
Condensers Gasket ID ............................................................................. 28-30
Condenser Front Endplate ID.................................................................... 31-34
For Shell-and-Tube stainless steel condensers (CA) used for high sulfur
content water and corrosive fluid applications, please contact customer
service for price and availability.
For Shell and tube vertical condensers (VSE), please contact customer
service for price and availability.
Evaporators
Evaporator Sizing ..................................................................................... 35-36
Selecting the Right Evaporator .......................................................................37
TX/TXC

Shell-and-Tube Super Compact Serviceable 1-Circuit ...... 38-39


Shell-and-Tube Super Compact Serviceable 2-Circuit ...... 40-41
Shell-and-Tube Super Compact R410A 1-Circuit ............. 42-43
Shell-and-Tube Super Compact R410A 2-Circuit ............. 44-45

Menu
Table of Contents Continued
The information contained herein is correct at the time of issue but may be subject to change without prior notice.

TXG

Shell-and-Tube Ultra compact Serviceable 1-Circuit ..............46


Shell-and-Tube Ultra compact Serviceable 2-Circuit ..............47

EVP-ACH

Copper-Brazed Plate Heat Exchanger


R410A - High Efficiency ........................................................48

EVP-ACH2

Copper-Brazed Plate Heat Exchanger


R410A - High Efficiency Dual Circuit .....................................49

ERS/ERD

Shell-and-Tube OEM replacement ................................... 50-51

Custom Design Evaporator Specification Sheet ..............................................52


Replacement Evaporator Gaskets Cross Reference Chart ..............................53
Refrigerant Subcoolers
SBC-AC
AlfaChill Copper-Brazed Plate Heat Exchangers ....................54
Chiller Builder Kits - Lowside
Chiller Builder Kit with shell-and-tube ..................................................... 55-57
BHE Chiller Builder Kit ............................................................................ 58-59
Liquid Receivers
Design Features and Ratings ..........................................................................60
HR

Horizontal Design ..................................................................61

RBV

Horizontal Design with Brackets and Valves ...........................62

UR

Upright Receivers ..................................................................63

UV

Upright Receivers with Valves ................................................64

Compact Vertical Receivers with Valve and Fusible Plug ........65

Valves, Brackets and Accessories


Rotalock Valves ............................................................................................66
(4) Bolt Flanged Valve and Indicator Components .........................................67
Float Type Indicators and Alarms ..................................................................68
Rotalock Adapters........................................................................................69
Safety Relief Devices and Sight Glasses .......................................................70
Brackets - Universal and Compressor Mounting ...........................................71
Warranty........................................................................................................ 75

Menu

Pressure Vessel Construction and Certification Information

Size of Vessel

Construction and Certification generally acceptable,


furnished unless otherwise specified

Under six inches ID

UL Listing

Six inches or greater ID, but less than 1.5 cubic feet net
internal volume

ASME Code Construction with UM Certification and UL


Recognition

Six inches or greater ID, with over 1.5 cubic feet net internal
volume

ASME Code Construction with U Certification and National


Board Registration

Notes
UL Listing may be obtained for a vessel, typical samples of
which can withstand five times the marked working pressure
without failure for the gas side and three times the marked
working pressure without failure for the fluid side. Initial tests are
made at Underwriters Laboratory and re-examination tests are
made under UL supervision, at the manufacturers plant.
ASME Code Construction is the same whether UM or U
certified. Essentially, the vessel must have a calculated design
strength capable of withstanding the maximum allowable
working pressure (MAWP) and tested pneumatically to 1.1
times the MAWP or hydrostatically to 1.3 times the MAWP.
Certain details of construction must be observed, and chemical
and physical test certification for all material must be on file.
Welding procedures, equipment, and personnel must be
qualified by performance tests. UM Certification means that
the manufacturers personnel have performed the necessary
inspection and tests. The letters UM appear in the ASME
cloverleaf stamp on the tag. Only when requested, a certificate
(Form U3) is furnished, signed by the manufacturer.
UL Recognition of UM vessels. Their testing and reexamination procedure is identical to that for listing. This
recognition requirement is because UL takes the position
that someone other than the manufacturer should check the
construction. The recognition list is not published as is the
listing the records are kept by UL and generally used only
when granting listing to an assembly that includes the vessel.

We recommend referring to Nat. Bd., rather than Ustamp, to


avoid confusion between U and UM.
Underwriters Laboratory will automatically accept a National
Board registered vessel when listing an assembly, because it
has been inspected by an independent agent, to specifications
stricter than their own.
A National Board certified vessel is accepted by all states and
municipal codes in the United States. Most other countries will
accept them also.
Certain government or military requirements essentially parallel
the ASME code, but may specify approval and/or certification
by inspectors from a government agency in addition to, or in
place of ASME code, or UL requirements.
International Code Stamps
CRN Canadian registration is available on cataloged and
custom models. CRN or special code requests must be made
at time of order.
Other international codes possibly available upon request
include New Zealand, Australia, Japan, China and Europe (CE).

National Board Registration means that in addition to the


ASME construction, an independent, licensed inspector has
monitored the procedures, fabrication and testing of the vessel.
The letter U appears in the ASME cloverleaf stamp on the tag.

Menu
Brazed Plate Heat Exchangers
The Brazed Heat Exchanger less is more
The brazed plate heat exchanger is the most compact heat exchanger on the market today. Its high heat transfer efficiency in
combination with its compact design equals a compact heat exchanger for a wide range of heating, cooling, evaporating and
condensing duties. The brazed heat exchanger consists of thin corrugated stainless steel plates brazed together with copper to
form a self-contained unit. Brazing the plates together eliminates the need for a frame, gaskets, bolts and the carrying bar. The
result is a heat exchanger that costs less, weighs less, holds less refrigerant and takes up less space.

Brazed Heat Exchangers

threaded and sweat connections


available in stock. Others available
on request.
seal plate
unique herringbone plate pattern
99.9% pure copper brazing
material
AISI 304 or 316L plates

channels formed when plates


are pressed together
threaded and sweat connections
available in stock. Others available
per request

How to Read Alfa Laval Part Numbers


Example: Part # ACH-500 DQ - 70H - F
Model Series

Features

# of Plates

Channel Type

ACH500

DQ

70

Brazing Material:
AC = Copper-Brazed
(AlfaChill)
ACH = CopperBrazed High
Pressure
(AlfaChill)
AN HP = Alfa Nova
High
Pressure
CB = Copper-Brazed
AN = Alfa Nova
Model type indicated
by the numbers 14,
27, 30, 52, 70, 76,
120, 230, 500

X = Integral Distributor
for Evaporative
Duties
EQ = Equalancer
Refrigerant
Distribution
System Single Circuit
DQ = Equalancer
Refrigerant
Distribution
System Dual Circuit

A = Combination Extra
High and High Theta
E = Extra High Theta
H = High Theta
L = Low Theta
M = Medium Theta
(combination High
and Low Theta)

Special Features

Material
Combination
F

A = ASME UM certification (CB52


and CB76 models only)
B = Frame and Press Plate Stud
Bolt Mounting with Integral
Distributor
C = Frame and Press Plate Stud
Bolt Mounting without Integral
Distributor
S = Frame Plate Stud Bolt
Mounting without Integral
Distributor
T = Pressure Plate Stud Bolt
Mounting without Integral
Distributor
U = Without Integral Distributor
and without Mounting Feet
Y = Frame Plate Stud Bolt
Mounting with Integral
Distributor
Z = Pressure Plate Stud Bolt
Mounting with Integral
Distributor

None = Channel plate: 316


Frame/Pressure
plate: 316
Connection: 316
F = Channel plate: 316
Frame/Pressure
plate: 304
Connection: 304
G = Channel plate: 304
Frame/Pressure
plate: 304
Connection: 304
C = Channel plate: 254 (SM0)
Frame/Pressure
plate: 316
Connection: 316

Menu
Condensers

Shell and Tube Heat Exchanger Advantages


Shell and tube heat exchangers have been around for a long time but still offer many benefits over alternative heat exchangers. Its
durability and versatility, with a wide range of material choices give the heat exchanger many advantages to meet application needs.
The vessel can easily be customized with regards to nozzle sizes and locations, and the mounting brackets can be set to match
existing equipment.

Evaporators
Shell and tube heat evaporators have larger passages, which
give the unit the capability to handle dirty fluids, and also
have the ability to be flushed for onsite cleaning. It can also
be easily repaired (by tube plugging, tube replacement, head
replacement) without the need to replace the entire unit.

Condensers
The shell side of the condenser provides additional pumpdown
capacity with the internal shell fluid inventory. Its larger
passages also offer a greater control in fluid pressure drop that
can be optimized when used with viscous liquids and/or high
flow rate conditions. The waterside of the condenser can easily
be cleaned to ensure many years of consistent performance.

Menu
Condensers

Selecting the Right Condenser

Sizing a Condenser
A properly sized condenser will have a heat transfer rate (or
capacity) equal to the system cooling load plus the energy
added to the refrigerant during the compression process. The
total of these two quantities is called the Total Heat Rejection
(THR). In the IP unit system, THR is usually specified in Btu/hr.
For most applications, the condenser capacity will not exactly
match the THR, so a condenser with the smallest excess
capacity is normally chosen.

1THR (Btu/hr) = cooling load (Btu/hr) +


compressor power input (Btu/hr)
Where:
Compressor power input (Btu/hr) = compressor
power input (kW) * 3413 Btu/hr/W
Sizing by Nominal hp
Often, the exact THR is not known, and it has to be
estimated. A rule of thumb for an air-conditioning
system operating at standard conditions is that for 1
ton (12,000 Btu/hr) of evaporator load, approximately
3000 Btu/hr is required by the compressor. Standard
conditions assume that the evaporator is operating at a
Saturated Suction Temperature (SST) of approximately
35F with less than 10F superheat, while the condenser
is operating at a Saturated Condensing Temperature
(SCT) of approximately 105F. Thus, the condenser has
to reject 15,000 Btu/hr for each 12,000 Btu/hr (or ton) of
evaporator load.
Compressors are usually rated by horsepower (HP). By
strict definition, 1 HP = 2545 Btu/hr. However, for ruleof-thumb purposes, one can round up and assume
that 1 HP is approximately 3000 Btu/hr, which happens
to be the same as the 3000 Btu/hr of compression
power required for 1 ton of evaporator load at standard
conditions discussed above. Thus, as a rule-of-thumb,

HSE-410

SST

a condenser must reject 15,000 Btu/hr for each 1 HP of


compressor power at standard conditions.
For convenience, most Standard condensers in the
following tables are rated by nominal horsepower (HP),
where 1 HP is defined to be 15,000 Btu/hr. Thus, for
standard conditions, one can choose a condenser that
has a rating similar to the HP rating of the compressor.
For example, if the system has a 15 HP compressor, one
can select a 15 HP condenser to match. The condenser
ratings using water (or sea water) as the cooling fluid
are based on entering fluid temperature (EFT), leaving
fluid temperature (LFT), SCT, and the entering refrigerant
temperature (ERT). The EFT, LFT, SCT, and ERT that
serve as the basis for the condenser rating are listed
below each table.
Sizing by Total Heat of Rejection
While the above method of selecting a condenser
is convenient, it can only be used when the actual
evaporator and condenser operating conditions are
close to standard conditions. If this stipulation is not
met, using the rule-of-thumb will result in the selection of
an oversized or undersized condenser, and the system
will not operate properly. In this case, a more rigorous
method must be used to determine THR. Compressor
performance data tables or software will be required
to determine the actual compressor power input and
compressor capacity for the design conditions, so that
an accurate THR can be computed. The calculated THR
(Btu/hr) can then be divided by 15,000 Btu/hr/HP to
determine the required compressor HP.
In addition, if the actual EFT, LFT, SCT and ERT are
not the same as the values that serve as the basis for
the table, if a refrigerant is used which is not included
in the table, or if a fluid other than water is used to
cool the condenser; the condenser capacity will not be
the same as that shown in the table. In this case, the

HP

ELT

VSE

Menu
Selecting the Right Condensers

Standard Refrigeration software must be used to select a


condenser for the actual operating conditions.
Additional Considerations
Pulldown
When a system is initially started, the evaporator load may
be significantly higher than the design load for a period of
time, as the process being cooled is taken from its higher
initial temperature to the design temperature. As a result,
the THR will be higher during this period. In many cases,
the compressor capacity can be reduced (by compressor
unloading or throttling the suction valve), thus preventing
a higher THR. However, if compressor capacity cannot
be reduced because a short pulldown time is needed, the
condenser may need to be oversized in order to prevent high
condensing pressure faults and/or to prevent the high side relief
valve from opening. As a rule-of-thumb, an additional 10%
capacity can be added to accommodate pulldown. However,
a more rigorous calculation involving compressor data should
be done.

Pumpdown capacity
The pumpdown capacity of a condenser is based on 80% of
the available shell side volume and is the amount of refrigerant
that the condenser can safely store. This value is listed in the
capacity tables. Upon shutdown, many systems pump most
of the refrigerant into the condenser for storage. Also, during
servicing, it is common to store the refrigerant in the condenser.
In these situations, if the system is not equipped with a liquid
receiver, the condenser must be capable of holding the entire
system charge. Packaged systems operating at standard
conditions usually require about 3 lb of refrigerant per ton of
refrigerating capacity. However, split systems, low temperature
systems, and other industrial systems may require up to 7 lb/
ton or more.

CA

Condensers

Subcooling and system charge


The capacities in the rating tables include approximately 5F
of subcooling. After the condenser is installed, the system
charge can be adjusted to obtain the desired subcooling. At
a minimum, enough charge must be added to the system
to keep the condenser liquid outlet nozzle covered, so that
uncondensed gas does not escape the condenser. If additional
subcooling is required, more charge can be added to the
system. However, as subcooling is increased, the capacity
of the condenser decreases. If more than 5F of subcooling
is required, the selection software should be used to size the
condenser. If more than 10F of subcooling is required, a
special condenser design is required.

Fouling
Over time, the fluid side of the condenser may become coated
with mineral deposits and other debris. This is known as
fouling, and decreases the capacity of the condenser. The
capacities in the rating tables include an industry accepted
fouling factor of 0.00025 hr*ft^2*F/Btu. This fouling factor is
adequate for well-maintained fluid systems. Most condenser
models have removable heads, and the inside of the tubes can
be periodically cleaned to remove the fouling. However, if the
cooling water is dirty or if it has a high mineral content, a higher
fouling factor may be needed, and the software should be used
to select a condenser. When the condenser is new and the
surfaces are clean, the condenser will have a slightly higher
capacity until the level of fouling reaches the design value.
We can build customized condensers if an application calls
for a modified condenser with additional valves, water or
refrigerant fittings, special mounting brackets, or other
accessories.
Condenser sizing and selection software can be downloaded
from www.stanref.com/StanRefPro/setup.exe

MSE

SCH/SCS
Copper-Brazed
(CND-CB)

AlfaChill
(CND-ACH)

AlfaNova
(CND-AN)

Menu
HSE - Shell-and-Tube Horizontal Super Efficient Water-Cooled Condensers

Condensers

Designed and rated for R410A Applications


Also Ideal as OEM and System Builder Replacement for R22 Applications
Cleanable, for general applications - High Refrigerant pressure rated
Note: for low pressure systems, please contact your representative for pricing and delivery

Design Features and Ratings


Models

R-22
Nominal
HP*

R-134a
Nominal
HP*

R-410A
Nominal
HP*

Dimensions (inches)
D

Connections (inches)

P (ids)

Q
(ids)

S
(fpt)

Gaskets (gaske-)

T
(fpt)

Front

Rear
15452

HSE2-410

3.0

2.9

2.8

5 9/16

27 1/8

22

1 1/8

5/8

1/2

3/8

3/4

15453

HSE3-410

3.7

3.6

3.5

6 5/8

27 3/8

22

7/8

5/8

3/8

3/4

9280

9194

HSE5-410

5.2

5.0

5.0

6 5/8

27 3/8

2 1/2

21 1/2

1 1/8

5/8

1/2

9280

9194

HSE7-410

7.4

7.1

7.2

6 5/8

33 3/8

2 1/2

27 1/2

1 3/8

7/8

1/2

1 1/4

9280

9194

HSE10-410

10.6

10.3

10.3

6 5/8

33 3/8

2 1/2

27 1/2

1 3/8

7/8

1/2

1 1/4

9280

9194

HSE15-410

16.9

16.2

16.2

8 5/8

33 3/8

27

2 1/8

1 5/8

1 1/8

1/2

10251

9265

HSE20A-410

22.7

22.1

22.1

8 5/8

52 3/4

45

2 1/8

1 5/8

1 1/8

1/2

4383

9267

HSE25A-410

28.1

27.0

26.9

8 5/8

52 3/4

45

2 1/8

2 1/8

1 3/8

1/2

4383

9267

HSE30A-410

34.1

33.2

33.1

10 3/4

53

45

2 1/8

2 1/8

1 3/8

1/2

2 1/2

9273

9270

HSE40A-410

45.3

43.5

43.4

10 3/4

65 1/4

57

2 1/16

2 1/8

1 3/8

1/2

9273

9270

HSE50A-410

56.7

54.3

55.0

10 3/4

65 1/4

57

2 1/16

2 5/8

1 5/8

1/2

9273

9270

HSE60-410

68.0

65.2

65.0

12 3/4

66 13/16

3 1/2

56 1/2

2 3/4

2 5/8

1 5/8

1/2

10077

10078

HSE70-410

79.3

76.1

75.9

12 3/4

66 13/16

3 1/2

56 1/2

2 3/4

3 1/8

2 1/8

1/2

10077

10078

HSE80-410

90.6

86.9

86.7

12 3/4

66 13/16

3 1/2

56 1/2

2 3/4

3 1/8

2 1/8

1/2

10077

10078

HSE100-410

117.5

112.9

112.7

12 3/4

107 5/8

3 1/2

92 1/2

3 1/8

2 1/8

3/4

10078

10078

HSE125-410

147.5

141.7

141.3

12 3/4

107 5/8

3 1/2

92 1/2

3 5/8

2 1/8

3/4

10078

10078

Larger models are available, please contact Customer Service


*R-22 ratings are based on 105F/160F/85F/95F with 5F of subcooling
*R-134a ratings are based on 105/125F/85F/95F with 5F of subcooling
*R-410A ratings are based on 105/125F/85F/95F with 5F of subcooling
Nominal ratings: Include a additive fouling coefficient of 0.00025 as calculated per AHRI Standard 450-2007
Standard Refrigeration software values are the most accurate
Tubing has high performance enhanced surface
HP = 15,000 Btu/hr.

Shell Side Working Pressure:


Tube Side Non-Code:

To download sizing and selection software, visit www.stanref.com/StanRefPro/setup.exe


L
B
S safety

P refrig. inlet

T fluid out
E

TAG

HSE-2 thru HSE-50A

D
E

Q refrig. outlet
L

P refrig. inlet
TAG

T fluid in

S safety

HSE - 60
HSE - 70
HSE - 80
Q refrig. outlet

10

T fluid out

E
D
E
T fluid in

600 psi @ 150 F


150 psi @ 150 F

Menu
HSE - Shell-and-Tube Horizontal Super Efficient Water-Cooled Condensers

Condensers

Designed and rated for R410A Applications


Also suited for refrigerants R22, R134A, R404A and R507 (consult with the factory for R407C)
Cleanable, for general applications - High Refrigerant pressure rated

Design Features and Ratings


Models

Pumpdown
Capacity
(lbs. R410A)

Waterflow (gpm)

Water
Pressure Drop (psi)

Shipping Weight
(lbs)

Min.

Max.

R-22

R-134a

R-410A

HSE2-410

11

1.3

13

2.8

2.6

2.6

38

HSE3-410

14

1.3

13

3.1

2.9

2.9

50

HSE5-410

18

2.7

27

2.8

2.7

2.7

69

HSE7-410

21

2.4

23

5.4

5.0

5.2

101

HSE10-410

20

3.4

34

5.9

5.6

5.6

93

HSE15-410

35

4.7

47

5.4

4.9

4.9

129

HSE20A-410

55

10.7

107

2.7

2.6

2.6

193

HSE25A-410

54

12.1

121

3.1

2.9

2.9

203

HSE30A-410

90

15

154

2.6

2.5

2.5

306

HSE40A-410

112

15

154

5.0

4.6

4.6

365

HSE50A-410

104

19

188

5.3

4.8

5.0

373

HSE60-410

155

22

221

4.8

4.5

4.5

484

HSE70-410

147

25

255

5.0

4.6

4.6

504

HSE80-410

138

29

295

5.1

4.7

4.7

544

HSE100-410

235

51

509

2.3

2.1

2.1

789

HSE125-410

210

64

643

2.5

2.3

2.3

853

To download sizing and selection software, visit www.stanref.com/StanRefPro/setup.exe


For larger sizes, please contact Customer Service.
Standard Refrigeration software values are the most accurate
Horizontal, cleanable shell and tube design
New high tech enhanced copper tube geometry
Smaller footprint equals less space requirement
Removable, epoxy coated, water plates to facilitate cleaning
Epoxy coated tube sheets to prevent pitting caused by galvanic action
27 HSE-410 models, 2 thru 500 horsepower

L
B
A
P refrig. inlet

S safety

TAG
HSE-100 and HSE-125

D
E

T fluid outlet

Q refrig. outlet

T fluid inlet

11

Menu
HSG - Shell-and-Tube Horizontal Water-Cooled Condensers 1-Circuit

Condensers

1-Circuit Features and Ratings


Models

R-22
Nominal
HP*

R-134a
Nominal
HP*

R-22
Nominal
Water Flow
(GPM)

R-134a
Nominal
Water Flow
(GPM)

R-22
Pressure
Drop
(PSI)

R-134a
Pressure
Drop
(PSI)

Shell
Diameter
(inches)

Overall
Length
(inches)

Tube
Side
Passes

Pumpdown
Capacity
(lb R22)

HSG15-1

14.4

14.4

44

46

3.9

4.3

6 5/8

39 1/2

24

HSG20-1

18.2

18.2

56

59

3.1

3.5

8 5/8

39 1/2

45

HSG30-1

30.2

30.2

92

95

3.6

3.8

8 5/8

39 1/2

37

HSG40-1

39.5

39.5

120

126

3.5

3.8

10 3/4

40

63

HSG50-1

49.1

49.1

150

154

3.8

3.9

10 3/4

40

55

HSG60-1

59.2

59.2

180

189

3.4

3.7

12 3/4

41

84

HSG70-1

68.8

68.8

210

215

3.5

3.7

12 3/4

41

77

HSG75-1

73.9

73.9

225

236

3.5

3.9

14

41

98

HSG85-1

83.5

83.5

255

261

3.7

3.9

14

41

91

HSG100-1

98.1

98.1

300

308

3.5

3.7

16

49 1/2

130

HSG115-1

110.3

110.3

336

345

3.5

3.7

16

49 1/2

120

HSG130-1

127.5

127.5

390

400

3.7

3.9

18

49 1/2

158

HSG150-1

158.8

158.8

484

506

6.0

6.6

18

52 1/2

187

HSG190-1

201.1

201.1

613

627

5.9

6.1

20

53

231

Larger models are available, please contact Customer Service


*R-22 ratings are based on 105F/160F/85F/95F with 5F of subcooling
*R-134a ratings are based on 105/125F/85F/95F with 5F of subcooling
Nominal ratings: Include a additive fouling coefficient of 0.00025 as calculated per AHRI

Horizontal, cleanable shell and tube design


Compact design
1 and 2-circuit designs
Smaller footprint equals less space
Models

Standard 450-2007
Standard Refrigeration software values are the most accurate
Flanged Connections Available Upon Request
HP = 15,000 Btu/hr.

Can be matched with TXG or brazed plate evaporators


Models suitable for standard refrigerants
For R410A, please contact Customer Service

Dimensions (inches)

Connections (inches)

P (ids)

Q (ids)

S (fpt)

T (fpt)

HSG15-1

6 5/8

38 1/2

2 1/2

33 1/2

10 5/8

1 1/8

7/8

1/2

1 1/2

HSG20-1

8 5/8

39 1/2

3 1/2

32 1/2

11 7/8

1 3/8

7/8

1/2

HSG30-1

8 5/8

39 1/2

3 1/2

32 1/2

11 7/8

1 5/8

1 1/8

1/2

2 1/2

1-Circuit

12

HSG40-1

10 3/4

40

3 1/2

32 1/2

14 1/4

2 1/8

1 1/8

1/2

HSG50-1

10 3/4

40

3 1/2

32 1/2

14 1/4

2 1/8

1 3/8

1/2

HSG60-1

12 3/4

41

3 1/2

32 1/2

16 7/8

2 1/8

1 3/8

1/2

HSG70-1

12 3/4

41

3 1/2

32

16 7/8

2 5/8

1 5/8

1/2

HSG75-1

14

41

3 1/2

32

17 7/8

2 5/8

1 5/8

1/2

HSG85-1

14

41

3 1/2

32

17 7/8

2 5/8

1 5/8

1/2

HSG100-1

16

46

3 1/2

31

20 1/8

3 1/8

1 5/8

1/2

HSG115-1

16

46

3 1/2

31

20 1/8

3 1/8

1 5/8

1/2

HSG130-1

18

49 1/2

5 1/4

30 3/4

22 1/4

3 5/8

2 1/8

1/2

HSG150-1

18

55 1/2

5 1/4

36 3/4

22 1/4

3 5/8

2 1/8

1/2

HSG190-1

20

53

5 1/4

36 3/4

24 1/4

3 5/8

2 5/8

1/2

Menu
HSG - Shell-and-Tube Horizontal Water-Cooled Condensers 2-Circuit

Condensers

2-Circuit Features and Ratings


Models

R-22
Nominal
HP*

R-134a
Nominal
HP*

HSG30-2

30.2

30.2

HSG40-2

39.5

39.5

HSG50-2

49.1

49.1

HSG60-2

59.2

HSG70-2

68.8

HSG75-2

R-22
Nominal
Water Flow
(GPM)

R-134a
Nominal
Water Flow
(GPM)

R-22
Pressure
Drop
(PSI)

R-134a
Pressure
Drop
(PSI)

Shell
Diameter
(inches)

Overall
Length
(inches)

92

92

3.6

120

120

3.5

150

150

59.2

180

68.8

210

73.9

73.9

Tube
Side
Passes

Pumpdown
Capacity
(lb R22)

3.6

8 5/8

39 1/2

35

3.5

10 3/4

40

60

3.8

3.8

10 3/4

40

53

180

3.4

3.4

12 3/4

41

80

210

3.5

3.5

12 3/4

41

73

225

225

3.5

3.5

14

41

94

HSG85-2

83.5

83.5

255

255

3.7

3.7

14

41

86

HSG100-2

98.1

98.1

300

300

3.5

3.5

16

49 1/2

124

HSG115-2

110.3

110.3

336

336

3.5

3.5

16

49 1/2

114

HSG130-2

127.5

127.5

390

390

3.7

3.7

18

49 1/2

151

HSG150-2

158.8

158.8

484

484

6.0

6.0

18

52 1/2

179

HSG190-2

201.1

201.1

613

613

5.9

5.9

20

53

221

Larger models are available, please contact Customer Service


*R-22 ratings are based on 105F/160F/85F/95F with 5F of subcooling
*R-134a ratings are based on 105/125F/85F/95F with 5F of subcooling
Nominal ratings: Include a additive fouling coefficient of 0.00025 as calculated per AHRI

Horizontal, cleanable shell and tube design


Compact design
1 and 2-circuit designs
Smaller footprint equals less space

Models

Standard 450-2007
Standard Refrigeration software values are the most accurate
Flanged Connections Available Upon Request
HP = 15,000 Btu/hr.

Can be matched with TXG or brazed plate evaporators


Models suitable for standard refrigerants
For R410A, please contact Customer Service

Dimensions (inches)

Connections (inches)

P (ids)

Q (ids)

S (fpt)

T (fpt)

HSG30-2

8 5/8

39 1/2

3 1/2

15

11 7/8

1 1/8

7/8

1/2

2 1/2

HSG40-2

10 3/4

40

3 1/2

15

14 1/4

1 3/8

7/8

1/2

HSG50-2

10 3/4

40

3 1/2

15

14 1/4

1 5/8

7/8

1/2

HSG60-2

12 3/4

41

3 1/2

15

16 7/8

1 5/8

1 1/8

1/2

HSG70-2

12 3/4

41

3 1/2

15

16 7/8

2 1/8

1 1/8

1/2

HSG75-2

14

41

3 1/2

15

17 7/8

2 1/8

1 1/8

1/2

HSG85-2

14

41

3 1/2

15

17 7/8

2 1/8

1 1/8

1/2

HSG100-2

16

46

3 1/2

15

20 1/8

2 1/8

1 3/8

1/2

HSG115-2

16

46

3 1/2

15

20 1/8

2 1/8

1 3/8

1/2

HSG130-2

18

49 1/2

5 1/4

14

22 1/4

2 5/8

1 5/8

1/2

HSG150-2

18

55 1/2

5 1/4

17

22 1/4

2 5/8

1 5/8

1/2

HSG190-2

20

53

5 1/4

17

24 1/4

3 1/8

1 5/8

1/2

13

Menu
SST - Shell-and-Tube High Pumpdown Condensers

Condensers

Shell-and-Tube Condensers
High pumpdown. General service applications

Design Features and Ratings


Models

R-22
Norminal
HP*

R-134a
Nominal
HP*

Pumpdown
Capacity
(lbs. R22)

SST-75A

0.8

0.8

Waterflow (gpm)

Water
Pressure Drop
(psi R-22)

Water
Pressure Drop
(psi R-134a)

Shipping
Weight (lbs)

2.3

1.3

1.3

28

Min.

Max.

0.7

SST-100A

1.6

1.6

17

0.7

4.7

4.3

3.8

39

SST-200A

2.6

2.5

15

2.0

18.0

1.1

1.0

52

SST-300A

4.4

4.3

21.0

2.0

16.0

3.4

3.3

71

SST-500A

5.9

5.7

35.0

2.7

26.8

2.5

2.4

90

SST-750A

8.9

8.6

32.0

4.0

30.0

2.9

2.7

109

SST-755A

13.8

13.4

53

3.4

20.0

10.6

10.1

144

SST-1000A

13.3

12.8

59

6.7

67.0

2.7

2.5

159

SST-1500A

19.8

19.1

65

8.0

70.0

3.7

3.4

180

SST-1555A

19.8

19.1

111

8.0

80.4

3.7

3.4

272

SST-2005A

27.5

26.5

138

8.0

80.4

5.5

5.2

313

SST-2026A

27.5

26.5

208

8.0

80.4

5.5

5.2

428

SST-2505A

34.3

33.1

135

10.1

100.5

5.2

4.9

345

SST-2527A

34.3

33.1

205

10.1

100.5

5.2

4.9

413

SST-3005A

41.2

39.7

128

12.1

100.1

5.5

5.1

350

Larger and R-410a models are available, please contact Customer Service
*R-22 ratings are based on 105F/160F/85F/95F with 5F of subcooling
*R-134a ratings are based on 105/125F/85F/95F with 5F of subcooling
Nominal ratings: Include a additive fouling coefficient of 0.00025 as calculated per AHRI Standard 450-2007
Standard Refrigeration software values are the most accurate
Tubing has high performance extended surface
HP = 15,000 Btu/hr.

14

Shell Side Working Pressure:


Tube Side Non-Code:

Industrys most widely used and trusted model


Heavy duty, horizontal, shell and tube design
Nominal ratings and sizes to handle the most demanding requirements
Removable, epoxy-coated, water plates to facilitate cleaning
All copper, heavy wall, straight tube water channels
Epoxy-coated tube sheets to prevent pitting caused by galvanic action
Generous pumpdown capacities
28 SST models, 34 through 200 horsepower

450 psi @ 150 F


150 psi @ 150 F

Menu
Condensers

SST - Shell-and-Tube High Pumpdown Condensers


Shell-and-Tube Condensers
High pumpdown. General service applications

Design Features and Ratings


Models

Dimensions (inches)
D

Connections (inches)
E

P
(ids)

Q
(ids)

S
(fpt)

T
(fpt)

SST75A

21 1/8

16

1 5/8

1/2

1/2

3/8

3/8

SST100A

21 1/2

2 1/8

15 14/16

1 7/8

5/8

1/2

3/8

1/2

SST200A

6 5/8

21 3/8

2 1/16

15 15/16

7/8

5/8

3/8

3/4

SST300A

6 5/8

27 3/8

2 1/16

21 15/16

7/8

5/8

3/8

3/4

SST500A

8 5/8

28

2 5/8

21 9/16

1 1/2

1 1/8

5/8

1/2

1 1/4

SST750A

8 5/8

28 1/2

2 1/2

21 1/2

1 1/2

1 3/8

7/8

1/2

1 1/4

SST755A

8 5/8

40 1/2

2 9/16

33 7/16

1 1/2

1 3/8

7/8

1/2

1 1/4

SST1000A

8 5/8

46 1/2

2 9/16

39 7/16

2 1/8

1 3/8

7/8

1/2

1 1/4

SST1500A

8 5/8

52

2 8/16

45 7/16

2 1/8

1 3/8

1 1/8

1/2

1 1/2

SST1555A

10 3/4

53 1/4

44 3/4

2 1/2

1 5/8

1 1/8

1/2

1 1/2

SST2005A

10 3/4

65 1/4

56 1/2

2 1/2

2 1/8

1 1/8

1/2

SST2026A

12 3/4

65 1/4

3 1/4

56 1/2

2 1/2

2 1/8

1 1/8

1/2

SST2505A

10 3/4

65 1/2

56 1/2

2 1/8

2 1/8

1 3/8

1/2

2 1/2

SST2527A

12 3/4

65 1/2

3 1/4

56 1/2

2 1/8

2 1/8

1 3/8

1/2

2 1/2

SST3005A

10 3/4

65 1/2

56 1/2

2 1/8

2 5/8

1 3/8

1/2

2 1/2

Larger and R-410a models are available, please contact Customer Service
*R-22 ratings are based on 105F/160F/85F/95F with 5F of subcooling
*R-134a ratings are based on 105/125F/85F/95F with 5F of subcooling
Nominal ratings: Include a additive fouling coefficient of 0.00025 as calculated per AHRI Standard 450-2007
Standard Refrigeration software values are the most accurate
Tubing has high performance extended surface
HP = 15,000 Btu/hr.

SST100
L

P refrig.
inlet
.

S safety

T fluid out
T fluid out

TAG
SST-75A thru SST-3005A
Q refrig.. outlet

E
D

T fluid in

E
T fluid in

15

Menu
CND-CB - Copper-Brazed Plate Heat Exchangers - General Service Single-Circuit

Condensers

CND-CB Single-Circuit Condensers are copper-brazed.


Optimized for R22.
Model

Nominal
HP*

Description

Four Frame Sizes

Part Number

Connections (ids)
Refrigerant
Inlet/Outlet
S4/S3

Water Inlet/
Outlet
S2/S1

Frame Size 8.2" H x 3.1" W

Dimensions (in.)
Dry
Wt.
(lbs.)

"D"

"A"

"B"

"C"

Working Pressure 500 PSIG

CND-03S-CB

0.3

CB14-12H S15

32870 5256 7

5/8"

5/8"

2.5

1.4

0.95

1.65

6.78

CND-05S-CB

0.4

CB14-14H S15

32870 0075 5

5/8"

5/8"

3.3

1.7

0.95

1.65

6.78

Frame Size 12.2" H x 4.4" W (Includes studbolts) Working Pressure 450 PSIG
CND-1M-CB

0.8

CB30-12H S15

3287099352

5/8"

5/8"

6.51

1.6

0.95

1.97

9.84

CND-1.5M-CB

1.5

CB30-18H S33

3287099353

7/8"

7/8"

7.84

2.15

0.95

1.97

9.84

CND-2M-CB

CB30-24H S33

3287099358

7/8"

7/8"

9.12

2.69

0.95

1.97

9.84

CND-3M-CB

CB30-34H S52

3287099359

1-1/8"

1-1/8"

11.38

3.6

0.95

1.97

9.84

CND-4M-CB

CB30-44H S52

3287099360

1-1/8"

1-1/8"

13.5

4.51

0.95

1.97

9.84

CND-5M-CB

CB30-54H S52

3287099361

1-1/8"

1-1/8"

15.63

5.42

0.95

1.97

9.84

CND-6M-CB

CB30-64H S52

3287099363

1-1/8"

1-1/8"

17.76

6.33

0.95

1.97

9.84

CND-4L-CB

CBH-60-16H S52

1.97

18.35

Frame Size 20.7" H x 4.4" W (Includes studbolts) Working Pressure 650 PSIG
3287103910

1-1/8"

1-1/8"

11.04

0.95

CND-6L-CB

CBH-60-24H S52

3287103911

1-1/8"

1-1/8"

14.15

2.7

0.95

1.97

18.35

CND-7.5L-CB

7.5

CBH-60-30H S52

3287103912

1-1/8"

1-1/8"

16.48

3.3

0.95

1.97

18.35

CND-10L-CB

10

CBH-60-40H S52

3287103913

1-1/8"

1-1/8"

20.36

4.2

0.95

1.97

18.35

CND-12.5L-CB

12.5

CBH-60-48H S52

3287103914

1-1/8"

1-1/8"

23.46

0.95

1.97

18.35

CND-14L-CB

14

CBH-60-62H S52

3287103915

1-1/8"

1-1/8"

28.89

6.3

0.95

1.97

18.35

CND-10XL-CB

10

CB76-20H S89

2-1/8"

2-1/8"

3.62

20.43

Frame Size 24.3" H x 7.6" W


32870 0095 7

Working Pressure 435 PSIG


36.2

2.61

1.58

CND-15XL-CB

15

CB76-30H S89

32870 0095 8

2-1/8"

2-1/8"

45.9

3.72

1.58

3.62

20.43

CND-20XL-CB

20

CB76-40H S89

32870 0095 9

2-1/8"

2-1/8"

55.6

4.83

1.58

3.62

20.43

CND-25XL-CB

27

CB76-50H S89

32870 0096 0

2-1/8"

2-1/8"

65.3

5.94

1.58

3.62

20.43

CND-30XL-CB

33

CB76-60H S89

32870 5095 2

2-1/8"

2-1/8"

75

7.05

1.58

3.62

20.43

CND-45XL-CB

46

CB76-80H S89

32870 5095 3

2-1/8"

2-1/8"

94.4

9.27

1.58

3.62

20.43

CND-60XL-CB

58

CB76-100H S89

32870 5095 4

2-1/8"

2-1/8"

113.8

11.49

1.58

3.62

20.43

*Nominal HP - 15K BTUH per HP, 195F EGT, 105F SCT R22, 5F Subcooling, 85F EWT, 95F LWT
FF=0.0001 Ft2/hr,F/BTU Water pressure drop less than 10 Psig
For performance with other refrigerants and/or fluids other than water, please contact Customer Service.

16

Menu
Condensers

CND-ACH - Copper-Brazed Plate Heat Exchangers - R410A High Efficiency Single-Circuit


CND-ACH Single-Circuit Condensers are copper-brazed.
Optimized for use with R410A.
Suitable for R22 and most common refrigerants.
Model

Nominal
HP1

Description

Part Number

Four Frame Sizes


Connections (ids)

Refrigerant
Inlet/Outlet
(S4/S3)

Water Inlet/
Outlet
(S2/S1)

Dimensions (in.)
Dry Wt.
(lbs.)

Frame Size 12.8" H x 3.7" W (Includes studbolts)

"B"

"C"

CND-0.75M-ACH

0.75

ACH-30EQ-10H R52

3287084893

7/8", 3/8"

7/8"

4.2

0.9

0.95

1.54

10.6

CND-1.5M-ACH

1.5

ACH-30EQ-20H R52

3287084894

7/8", 3/8"

7/8"

6.2

1.5

0.95

1.54

10.6

CND-3M-ACH

ACH-30EQ-30H S09

3287084895

7/8", 1/2"

7/8"

8.2

2.1

0.95

1.54

10.6

CND-4M-ACH

ACH-30EQ-40H S09

3287084896

7/8", 1/2"

7/8"

10.2

2.7

0.95

1.54

10.6

CND-5M-ACH

ACH-30EQ-50H S21

3287084897

1-1/8", 5/8"

1-1/8"

12.2

3.3

0.95

1.54

10.6

CND-6M-ACH

ACH-30EQ-60H S21

3287084898

1-1/8", 5/8"

1-1/8"

14.2

3.9

0.95

1.54

10.6

CND-5L-AC

Working Pressure 650 PSIG

ACH-70X-22M S21

3287083717

1-1/8", 5/8"

1-1/8"

11.3

3.3

0.95

1.97

18.35

CND-6L-AC

ACH-70X-26M S21

3287083718

1-1/8", 5/8"

1-1/8"

12.9

3.7

0.95

1.97

18.35

CND-7.5L-AC

7.5

ACH-70X-32M S21

3287083719

1-1/8", 5/8"

1-1/8"

15.3

4.2

0.95

1.97

18.35

CND-10L-AC

10

ACH-70X-42M S24

3287083720

1-3/8", 5/8"

1-1/8"

19.3

5.1

0.95

1.97

18.35

CND-12L-AC

12

ACH-70X-50M S24

3287083721

1-3/8", 5/8"

1-1/8"

22.5

5.9

0.95

1.97

18.35

CND-15L-AC

15

ACH-70X-62M S25

3287083723

1-3/8", 5/8"

1-3/8"

27.3

0.95

1.97

18.35

CND-20L-AC

20

ACH-70X-78M R49

3287083725

1-3/8", 7/8"

1-3/8"

33.7

8.4

0.95

1.97

18.35

CND-25L-AC

24

ACH-70X-100M R49

3287083727

1-3/8", 7/8"

1-3/8"

42.4

10.4

0.95

1.97

18.35

Frame Size 24.3" H x 7.6" W (Includes studbolts)

Working Pressure 650 PSIG

CND-12.5XL-ACH

12.5

ACH-120EQ-30H S46

3287083729

2-1/8", 7/8"

2-1/8"

45.9

3.3

1.58, 0.95

3.62

20.43

CND-20XL-ACH

20

ACH-120EQ-46H S62

3287083731

2-1/8", 1-1/8"

2-1/8"

61.4

6.1

1.58, 0.95

3.62

20.43

CND-25XL-ACH

25

ACH-120EQ-60H S62

3287083732

2-1/8", 1-1/8"

2-1/8"

75

6.1

1.58, 0.95

3.62

20.43

CND-30XL-ACH

30

ACH-120EQ-76H S62

3287083733

2-1/8", 1-1/8"

2-1/8"

90.5

7.6

1.58, 0.95

3.62

20.43

CND-40XL-ACH

40

ACH-120EQ-90H S62

3287083734

2-1/8", 1-1/8"

2-1/8"

104.1

8.9

1.58, 0.95

3.62

20.43

CND-45XL-ACH

45

ACH-120EQ-106H S62

3287083735

2-1/8", 1-1/8"

2-1/8"

119.6

10.4

1.58, 0.95

3.62

20.43

CND-50L-ACH

50

ACH-120EQ-124H S62

3287083736

2-1/8", 1-1/8"

2-1/8"

137.1

12.1

1.58, 0.95

3.62

20.43

Frame Size 29.0" H x 13.0" W (Includes lifting lugs and feet)

"A"
Liq, Suct, Water

Working Pressure 650 PSIG

Frame Size 20.7" H x 4.4" W (Includes studbolts)

"D"

Working Pressure 650 PSIG

CND-50XXL-ACH

50

ACH-500EQ-70H Y55

3287084411

2-5/8",1-3/8"

3" Victaulic

162.7

7.66

1.18, 2.05, 2.05

4.03

24.88

CND-60XXL-ACH

60

ACH-500EQ-80H Y55

3287084412

2-5/8",1-3/8"

3" Victaulic

181.2

8.69

1.18, 2.05, 2.05

4.03

24.88

CND-75XXL-ACH

75

ACH-500EQ-100H Y55

3287084414

2-5/8",1-3/8"

3" Victaulic

218.2

10.75

1.18, 2.05, 2.05

4.03

24.88

CND-100XXL-ACH

100

ACH-500EQ-130H Y55

3287084415

2-5/8",1-3/8"

3" Victaulic

273.7

13.83

1.18, 2.05, 2.05

4.03

24.88

Nominal Tons - 15,000 BTU/H per Ton, 195 degF EGT, 105 degF SCT R410A, 5 degF Subcooling, 85 degF EWT, 95 degF LWT. 3GPM per Ton. Water pressure drop less than 10 PSIG
For performance with other refrigerants and/or fluids other than water, please contact Customer Service.

17

Menu
CND-ACH2 - Copper-Brazed Plate Heat Exchangers R410A - High Efficiency
Dual-Circuited models

Condensers

CND-ACH2 Two Circuit Condensers are copper-brazed.


Optimized for use with R410A.
Suitable for R22 and most common refrigerants.
Model

Nominal
HP*

Description

Part
Number

Two Frame Sizes

Connections (ids)

Front Plate
Ref. In/Out3

Rear Plate
Water
In/Out
T1 - T2

Dimensions (in.)
Dry
Wt.
(lbs.)

Frame Size 19" H x 10" W (Includes studbolts)

"D"

"A"
Liq, Suct,
Water

"B"
front

"C"
front/rear

Working Pressure 650 PSIG

CND-12.5L-ACH2

12.5

ACH-230DQ-30H

3287084565

1 1/8",7/8"

2" Victaulic

38

3.9

0.95, 1.18, 1.89

6.10

15.75, 14.53

CND-20L-ACH2

20

ACH-230DQ-50H

3287084567

1 3/8",7/8"

2" Victaulic

56

6.2

0.95, 1.18, 1.89

6.10

15.75, 14.53

CND-30L-ACH2

30

ACH-230DQ-70H

3287084569

1 3/8",7/8"

2" Victaulic

73

8.6

0.95, 1.18, 1.89

6.10

15.75, 14.53

CND-40L-ACH2

40

ACH-230DQ-90H

3287084570

1 5/8",7/8"

2-1/2" Victaulic

93

10.9

0.95, 1.18, 1.89

6.10

15.75, 14.53

CND-50L-ACH2

50

ACH-230DQ-110H

3287084571

1 5/8", 1 1/8"

2-1/2" Victaulic

109

13.2

0.95, 1.18, 1.89

6.10

15.75, 14.53

CND-60L-ACH2

60

ACH-230DQ-138H

3287084572

2 1/8", 1 1/8"

2-1/2" Victaulic

134

16.5

0.95, 1.57, 1.89

6.10

15.75, 14.53

CND-70L-ACH2

70

ACH-230DQ-170H

3287084573

2 1/8", 1 1/8"

2-1/2" Victaulic

162

20.2

0.95, 1.57, 1.89

6.10

15.75, 14.53

CND-80L-ACH2

80

ACH-230DQ-202H

3287084574

2 1/8", 1 1/8"

2-1/2" Victaulic

190

23.9

0.95, 1.57, 1.89

6.10

15.75, 14.53

CND-100XXL-ACH2

100

ACH-500DQ-110H

3287084579

2 5/8",1 3/8"

3" Victaulic

238

11.8

1.18, 2.05, 2.05

8.07

24.87, 22.36

CND-120XXL-ACH2

120

ACH-500DQ-138H

3287084581

2 5/8",1 3/8"

3" Victaulic

290

14.7

1.18, 2.05, 2.05

8.07

24.87, 22.36

CND-140XXL-ACH2

140

ACH-500DQ-170H

3287084583

2 5/8",1 3/8"

3" Victaulic

349

17.9

1.18, 2.05, 2.05

8.07

24.87, 22.36

CND-150XXL-ACH2

150

ACH-500DQ-190H

3287084584

2 5/8",1 3/8"

3" Victaulic

386

20.0

1.18, 2.05, 2.05

8.07

24.87, 22.36

CND-160XXL-ACH2

160

ACH-500DQ-206H

3287084585

2 5/8",1 3/8"

3" Victaulic

416

21.6

1.18, 2.05, 2.05

8.07

24.87, 22.36

Frame Size 29" H x 13" W (Includes lifting lugs and feet)

Working Pressure 650 PSIG

Nominal Tons - 15,000 BTU/H per Ton, 195 degF EGT, 105 degF SCT R410A, 5 degF Subcooling, 85 degF EWT, 95 degF LWT. 3GPM per Ton. Water
2
For performance with other refrigerants and/or fluids other than water, please contact Customer Service.
3
Diagonal flow connectons.
1

18

Menu
MSE - Shell-and-Tube Marine Service Condensers

Models

R-22
Nominal
HP*

R-134a
Nominal
HP*

Pumpdown
Capacity
(lbs.)

Condensers

Water
Pressure Drop
(psi R-22)

Water
Pressure Drop
(psi R-134a)

Shipping
Weight
(lbs)

Working Pressure (psi)


Shell Side

Tube Side

MSE-100

0.9

0.8

14

1.4

1.2

35

400

150

MSE-200

1.7

1.7

12

2.1

2.0

49

400

150

MSE-300

2.9

2.7

14

3.7

3.4

58

400

150

MSE-500

3.8

3.7

15

4.1

3.8

77

400

150

MSE-750

6.7

6.3

24

2.1

1.9

107

400

150

MSE-1005

8.8

8.3

29

3.8

3.4

121

400

150

MSE-1500

14.4

13.9

49

3.3

3.1

181

400

150

MSE-2005

21.5

20.5

86

2.2

2.0

254

400

150

MSE-2505

26.3

25.1

79

2.4

2.2

265

400

150

MSE-3006

30.8

29.3

99

3.3

3.1

286

400

150

MSE-3305

33.2

32.2

133

2.1

2.0

338

400

150

MSE-4005

35.9

34.2

129

2.3

2.1

343

400

150

MSE-4505

42.9

40.8

160

3.8

3.4

388

400

150

MSE-5005

46.2

44.0

155

3.9

3.6

394

400

150

MSE-6505

60.0

57.1

225

3.2

2.9

517

400

150

MSE-7505

67.0

63.7

215

3.1

2.9

533

400

125

MSE-100HP

108.0

103.1

348

2.3

2.1

1133

400

125

MSE-120HP

118.3

113.1

344

1.9

1.7

1158

400

125

Larger and R-410a models are available, please contact Customer Service
Zinc plate are available for all MSE models. Indicate by adding "Z" after model number (MSE-750Z)
*R-22 ratings are based on 105F/160F/85F/95F with 5F of subcooling
*R-134a ratings are based on 105/125F/85F/95F with 5F of subcooling
Fouled ratings: Include a additive fouling coefficient of 0.00025 as calculated per AHRI Standard 450-2007
Standard Refrigeration software values are the most accurate
Tubing has high performance extended surface
HP = 15,000 Btu/hr.

Marine service
Heavy duty, horizontal,
shell-and-tube design
Nominal ratings and sizes to
handle the most demanding
requirements
Solid cupronickel tube sheets to
prevent pitting caused by galvanic
action
Removable, solid cupronickel or
solid brass water plates to facilitate
cleaning
All 90/10 cupronickel, heavy wall,
straight tube water channels
Sacrificial zinc anode available
upon request
Generous pumpdown capacities
Dual refrigerant outlets, provides
liquid seal in heavy seas
Custom designs to 500
horsepower on request
18 MSE stock models, 1 to 120
horsepower

P refrig. inlet
TAG

S safety

A
T fluid out

MSE6505
MSE7505

Q refrig. outlet
T fluid in
L
P refrig. inlet
TAG

T fluid out

B
A
S safety

MSE100HP
MSE120HP

Q refrig. outlet

T fluid inlet

19

Menu
MSE - Shell-and-Tube Marine Service Condensers

Condensers

Cupronickel Marine Service Condensers


Design Features and Ratings
Models

Dimensions (inches)

Connections (inches)

P (ids)

Q (ids)

S (fpt)

T (fpt)

21 5/8

1 5/8

16 3/8

1 7/8

5/8

1/2

3/8

1/2

MSE-200

21 5/8

1 5/8

16 3/8

1 7/8

7/8

5/8

3/8

1/2

MSE-300

6 5/8

22

16

7/8

5/8

3/8

3/4

MSE-500

6 5/8

22

2.06

15 15/16

1 1/8

5/8

3/8

3/4

MSE-100

MSE-750

6 5/8

34 1/4

28

1 3/8

7/8

3/8

1 1/4

MSE-1005

6 5/8

40 1/4

33

1 3/8

7/8

3/8

1 1/4

MSE-1500

8 5/8

40

2 1/2

33 1/2

2 1/8

1 5/8

1 1/8

1/2

MSE-2005

8 5/8

64 1/2

57

2 1/8

2 1/8

1 1/8

1/2

MSE-2505

8 5/8

64 1/2

57

2 1/8

2 1/8

1 3/8

1/2

MSE-3006

8 5/8

76 1/2

69

2 5/8

1 3/8

1/2

2 1/2

MSE-3305

10 3/4

65

56 1/2

2 1/8

2 5/8

1 3/8

1/2

2 1/2

MSE-4005

10 3/4

65

56 1/2

2 1/8

2 5/8

1 5/8

1/2

2 1/2

MSE-4505

10 3/4

77

68 1/2

2 1/8

2 5/8

1 5/8

1/2

2 1/2

MSE-5005

10 3/4

77

68 1/2

2 1/8

2 5/8

1 5/8

1/2

2 1/2

MSE-6505

12 3/4

78 11/16

3 1/2

68 1/2

2 3/4

3 1/8

2 1/8

1/2

MSE-7505

12 3/4

78 11/16

3 1/2

68 1/2

2 3/4

3 1/8

2 1/8

1/2

MSE-100HP

12 3/4

133 3/8

3 1/2

116 1/2

3 1/8

2 1/8

1/2

5 MPT

MSE-120HP

12 3/4

133 1/2

3 1/2

115 3/4

3 5/8

2 1/8

1/2

5 MPT

Standard Refrigeration software values are the most accurate

L
B
P refrig. inlet

S safety

T fluid out

TAG
MSE100 through MSE5005

Q refrig. outlet

20

T fluid in

Menu
Condensers

CND-AN - Alfa Nova - Fusion-bonded Plate Heat Exchangers

The AlfaNova is a copper-free, 100-percent stainless steel, corrosion-resistant design.


Optimized for R22.
Model

Nominal
HP*

Description

Part Number

Connections (ids)
Ref.
In/Out
S4/S3

Frame Size 12.2" H x 4.4" W

Water In/
Out
S2/S1

Three Frame Sizes


Dimensions (in.)

Dry
Wt.
(lbs.)

"D"

"A"

"B"

"C"

Working Pressure 435 PSIG

CND-2M-AN

AN27-20H S52

3287000880

1-1/8"

1-1/8"

8.5

2.34

0.95

1.97

9.4

CND-3M-AN

3.2

AN27-30H S52

3287000882

1-1/8"

1-1/8"

11.36

3.29

0.95

1.97

9.4

CND-5M-AN

5.5

AN27-50H S52

3287000884

1-1/8"

1-1/8"

17.09

5.19

0.95

1.97

9.4

CND-7M-AN

6.7

AN27-60H S53

3287000998

1-1/8"

1-1/8"

19.96

6.15

0.95

1.97

9.4

CND-8M-AN

7.9

AN27-70H S52

3287000999

1-1/8"

1-1/8"

22.83

7.10

0.95

1.97

9.4

CND-10M-AN

AN27-80H S52

3287001000

1-1/8"

1-1/8"

25.69

8.05

0.95

1.97

9.4

Frame Size 20.7" H x 4.4" W

Working Pressure 435 PSIG

CND-6L-AN

6.4

AN52-20H S52

3287000902

1-1/8"

1-1/8"

14.22

2.35

0.95

1.97

18.35

CND-10L-AN

10.1

AN52-30H S52

3287000904

1-1/8"

1-1/8"

18.98

3.32

0.95

1.97

18.35

CND-14L-AN

13.8

AN52-40H S52

3287000906

1-1/8"

1-1/8"

23.74

4.3

0.95

1.97

18.35

CND-15L-AN

14.6

AN52-50H S52

3287000907

1-1/8"

1-1/8"

28.51

5.2

0.95

1.97

18.35

Frame Size 24.4" H x 7.5" W

Working Pressure 650 PSIG

CND-15XL-AN

16.3

AN HP76-30H W16 UL

3287000916

2" weld

2" weld

51.8

3.7

1.57

3.62

20.43

CND-20XL-AN

22.1

AN HP76-40H W16 UL

3287000917

2" weld

2" weld

63.09

4.83

1.57

3.62

20.43

CND-30XL-AN

28.2

AN HP76-50H W16 UL

3287000918

2" weld

2" weld

73.83

5.96

1.57

3.62

20.43

CND-35XL-AN

34.2

AN HP76-60H W16 UL

3287000919

2" weld

2" weld

84.52

7.09

1.57

3.62

20.43

CND-45XL-AN

46.2

AN HP76-80H W16 UL

3287000921

2" weld

2" weld

95.22

8.22

1.57

3.62

20.43

CND-50XL-AN

52.2

AN HP76-90H W16 UL

3287000922

2" weld

2" weld

95.22

9.35

1.57

3.62

20.43

CND-60XL-AN

58.2

AN HP76-100H W16 UL

3287000923

2" weld

2" weld

95.22

10.48

1.57

3.62

20.43

*Nominal HP - 15K BTUH per HP, 195F EGT, 105F SCT R22, 5F Subcooling, 85F EWT, 95F LWT
FF=0.0001 Ft2/hr,F/BTU Water pressure drop less than 10 Psig
For performance with other refrigerants and/or fluids other than water, please contact Customer Service.

21

Menu
ELT - Tube-in-Tube Compact Condensers

Condensers

Tube-In-Tube Condensers
compact, cleanable

Design Features and Ratings


Models

Nominal
hp

Dimensions (inches)

Connections (inches)

P (ids)

Q (ids)

T (ids)

11

16 1/2

5/8

1/2

3/4

ELT-100A

3 1/8

21 1/2

ELT-150A

1 1/2

2 15/16

27

11

21 1/2

4 1/4

7/8

1/2

7/8

ELT-200A

2 15/16

27

12 5/8

21 1/2

4 1/4

7/8

1/2

7/8

ELT-300A

4 1/4

26 15/16

17 3/4

21 1/2

4 1/4

7/8

5/8

1 3/8

ELT-500A

4 1/4

26 15/16

17 3/4

21 1/2

4 1/4

7/8

7/8

1 3/8

ELT-800A

5 1/4

27 4/9

22 1/4

21 1/2

4 1/4

1 3/8

7/8

1 3/8

ELT-1000A

10

5 1/2

27 4/9

22 1/4

21 1/2

4 1/4

6 1/4

1 3/8

7/8

1 5/8

Nominal HP: As tested per AHRI standard 450-2007


HP = 15,000 BTU/hr.

Models

Waterflow (gpm)
Min.

Max.

Nom'l. Water
Pressure Drop
(psi)

Working Pressure (psi)


Shell Side

Tube Side

ELT-100A

0.7

6.7

1.25

21

380

200

ELT-150A

0.7

6.7

2.99

23

380

200

ELT-200A

0.7

6.7

6.40

27

380

200

ELT-300A

1.3

13.4

4.34

48

380

200

ELT-500A

2.0

20.1

5.49

50

380

200

ELT-800A

3.4

33.5

5.09

85

380

200

ELT-1000A

4.0

40.2

5.46

90

380

200

Consult customer service for performance data not shown.


R410A models available, contact Customer Service

Shipping
Weight (lbs)

Specially designed removable water plates and


gaskets allow unsurpassed ease of servicing or
cleaning without disconnecting water or refrigerant
lines
All copper water channels
Rugged steel construction to resist tubing damage
Our smallest horizontal, tube-in-tube design
Exceptional heat transfer utilizing enhanced tube
surfaces
Highest water pressure ratings, and lowest water
pressure drop offered in a cleanable tube-in-tube
condenser design
7 ELT models, up to 10 horsepower

400 psi.shell side on request

ELT 100A/ELT 150A/ ELT 300A


ELT 500A/ ELT 800A/ ELT 1000A
L

T fluid outlet
P refrig. inlet

Q refrig. outlet
T fluid inlet

ELT 200A
D

L
T fluid outlet
P refrig. inlet

refrig. outlet Q
fluid inlet T
A
22

Menu
SCH/SCS - Coaxial Style Water Cooled Condensers

Condensers

Coaxial Condensers
Ideal for heat pump and water cooler applications
Optimized for use with Refrigerant R410A. Suitable for R22 and most common refrigerants
Design Features and Ratings
Models

Nom'l
HP

Dimensions (inches)

Connections

Refrig. R
(ods)

Fluid F
(ods)

Ship Wt.
(lbs)

SCH-04

.33

1.25

4.00

5.75

6.75

9.25

2.50

5.63

.375

.375

.625

SCH-06

.50

1.31

5.06

5.75

6.75

9.25

2.50

5.63

.375

.375

.625

SCH-09

.75

1.31

6.19

5.88

6.75

9.25

2.50

6.75

.375

.375

.625

SCH-12

1.00

1.41

7.28

5.88

6.75

9.25

2.50

7.94

.375

.375

.625

12

SCH-18

1.50

1.31

5.19

11.50

12.50

13.00

6.00

5.88

.500

.500

.625

16

SCS-24

2.00

4.75

3.38

10.00

12.75

14.00

6.00

5.50

.500

.500

.750

25

SCS-30

2.50

4.56

4.00

10.00

12.75

14.00

6.00

5.38

.500

.500

.750

31

SCS-36

3.00

5.00

4.75

11.25

14.50

15.38

6.00

6.50

.500

.625

.875

35

SCS-42

3.50

4.75

4.63

12.50

15.50

16.00

6.00

5.75

.500

.625

.875

37

SCS-48

4.00

6.00

5.13

14.50

17.75

18.50

6.00

6.88

.500

.875

1.125

55

SCS-60

5.00

6.75

5.75

14.63

18.00

19.00

6.00

7.63

.500

.875

1.125

59

SCS-84

7.00

8.13

6.00

15.50

20.50

22.50

6.00

9.63

.500

.875

1.375

75

Cupronickel
Models

SCH-12CN

Nom'l
HP

1.00

Dimensions (inches)

Connections

Ship
Wt. (lbs)

Refrig. R
(ods)

Fluid F
(ods)

1.41

7.28

5.88

6.75

9.25

2.50

7.94

.375

.375

.625

Working Pressure
(psi)

12

Shell

Tube

600

350

SCH-18CN

1.50

1.31

5.19

11.50

12.50

13.00

6.00

5.88

.500

.500

.750

16

600

350

SCS-24CN

2.00

4.75

3.38

10.00

12.75

14.00

6.00

5.50

.500

.500

.750

25

600

350

SCS-36CN

3.00

5.00

4.75

11.25

14.50

15.38

6.00

6.50

.500

.625

.875

35

600

350

SCS-48CN

4.00

6.00

5.13

14.50

17.75

18.50

6.00

6.88

.500

.875

1.125

55

600

350

SCS-60CN

5.00

6.75

5.75

14.63

18.00

19.00

6.00

7.63

.500

.875

1.125

59

600

350

Nominal HP ratings as per ARI standard 450-2007

High efficiency counterflow design


Ideal for domestic heat pumps, and water coolers
Replacement models for most manufactures
Copper and 90/10 Cupronickel tube models stocked
UL and CSA listed
18 coaxial models from, 13 to 7 hp

Spiral SCS models

Helix SCH models


J

F fluid

F fluid

D
G

R refrig

A
E

R refrig

A
B

23

Menu

Condenser Specification Data

Fax to: 708-345-3513


or e-mail: stanref.customerservice@alfalaval.com

Customer Information
Company ______________________________________________________________________________________________________
Contact Name ____________________________________________

Date __________________________________________

Phone _______________________________________________________ Fax _____________________________________________


E-Mail: _________________________________________________________________________________________________________

Performance

Fluid Circulated

inlet fluid temperature _______________________F

water _________________________%

condensing refrigerant temperature____________F

propylene glycol________________%

fouling factor (.00025 ARI standard)____________

sodium chloride (NaCl)___________%

THR _____________________________________Btu/hr

ethylene glycol _________________%

refrigerant ________________________________

calcium chloride (CaCl2)__________%

pressure drop _____________________________psi

other__________________________%

Type

If other, specify properties at inlet temperature

Brazed Plate

specific gravity _________________________

Shell-and-Tube

thermal conductivity ____________________


viscosity (centipose) ____________________
specific heat ___________________________

Construction
size: width _______________________ length____________________________ height __________________________
connections: refrigerant inlet ____________________________ refrigerant outlet ______________________________
specify ids, fpt, flange or flare: fluid inlet _________________________ fluid outlet _____________________________

Application
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________

Menu
SST - Gasket and Endplates Cross Reference

Condensers

Condensers

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

Rear
Endplate
ENDPL-

SST 75A

3156

346

4304

30

Condensers

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

Rear
Endplate
ENDPL-

*SST 3028

256

265

148

184

*SST 75

337

346

49

30

*SST 30-460M

166

111

166

157

SST 100A

3163

3149

5040

5026

SST 3505A

2591

2984

6205

4180

*SST 100

175

184

67

58

*SST 35-520M

166

111

201

157

*SST 150

175

184

67

58

SST 4005A

111

120

210

238

SST 200A

3101

3170

5819

76

*SST 40-610M

111

120

210

238

*SST 200

193

201

85

76

SST 4505A

111

120

210

238

SST 300A

3101

3170

5819

76

*SST 45-680M

111

120

210

238

*SST 300

193

201

85

76

SST 5005A

111

120

247

238

SST 500A

3118

2584

5938

4047

*SST 50-760M

111

120

210

238

*SST 500

210

229

120

21

SST 5505A

111

120

247

238

SST 750A

3118

2584

5938

4047

*SST 55-850M

111

120

210

238

SST 750

210

229

12

21

SST 6005A

111

120

247

238

*SST 755A

3118

2584

5938

4047

*SST 60-940M

111

120

247

238

SST 755

238

247

12

21

SST 7005A

111

120

247

238

SST 1000A

1723

2953

6605

4047

*SST 70-1060M

111

120

247

238

*SST 1000

238

247

12

21

SST 8005A

111

120

247

238

SST 1500A

1723

2953

5576

4047

*SST 80-1200M

111

120

247

238

*SST 1501

2977

2584

175

4047

SST 100-1408A

120

120

2245

2245

SST 1555A

2591

2984

5907

4180

*SST 100-1500M

111

120

247

238

*SST 1555

256

265

193

184

SST 120-1408A

120

120

2245

2245

SST 2005A

2591

2984

5914

4180

*SST 126-1905M

120

120

3994

3994

*SST 2005

256

265

148

184

SST 150-1410A

120

120

2245

2245

SST 2026A

2591

2984

5914

4180

*SST 150-2250M

2254

2254

'H1039

'H1039

*SST 2026

256

265

148

184

SST 200-1412A

120

120

4335

4335

SST 2505A

2591

2984

6205

4180

*SST 200-3000M

2263

2263

'H1048

'H1048

*SST 2505

256

265

148

184

*SST 250-3750M

1679

1679

'H1057

'H1057

SST 2527A

2591

2984

6205

4180

*SST 300-4500M

1688

1688

'H1066

'H1066

*SST 2527

256

265

148

184

*SST 350-5250M

1688

1688

'H1066

'H1066

SST 3005A

2591

2984

6205

4180

*SST 400-6000M

2290

2290

'H1921

'H1921

*SST 3005

256

265

148

184

*SST 500-7500M

2290

2290

'H1921

'H1921

SST 3028A

2591

2984

6205

4180

These chart is to be used for reference purposes only.


For replacement parts contact customer service with your condenser model and serial numbers.
* Indicates that model is obsolete and no longer manufactured.

25

Menu
HSE/HP/CA/MSE - Gasket and Endplates Cross Reference

Condensers

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

HSE 2

337

346

HSE 3

175

184

HSE 5

3718

HSE 7

3718

HSE 10

3718

Condensers

Rear
Endplate
ENDPL-

Condensers

6412

30

HP 10

Call Factory

6717

5026

HP 15

Call Factory

3170

6229

76

HP 20

Call Factory

3170

5552

76

HP 30

Call Factory

3170

5552

76

HP 40

Call Factory

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

HSE 15

445

247

5495

21

HP 50

Call Factory

HSE 20A

2953

2584

5707

4047

HP 60

Call Factory

HP 80

Call Factory

*HSE 20

1723

1732

2227

21

HSE 25A

2953

2584

5707

4047

*HSE 25

1723

1732

2227

21

HSE 30A

1741

2984

5583

4180

*HSE 30

1741

1750

2236

4180

HSE 40A

1741

2984

6900

4180

Condensers

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

Rear
Endplate
ENDPL-

CA 050

355

364

2876

2885

CA 075

238

247

2911

2902

*HSE 40

1741

1750

2236

4180

CA 100

238

247

2911

2902

HSE 50A

1741

2984

6900

4180

CA 150

256

265

2920

2948

*HSE 50

1741

1750

2236

4180

CA 200

445

247

2894

2902

HSE 60

111

120

247

238

CA 300

373

265

2939

2948

HSE 70

111

120

247

238

HSE 80

111

120

247

238

HSE 100

120

120

2245

2245

Condensers

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

Rear
Endplate
ENDPL-

HSE 125

120

120

2245

2245

MSE 100

3163

3149

6436

300

HSE 150

2254

2254

'H1039

'H1039

MSE 200

3163

3149

6436

300

HSE 200

2263

2263

'H1048

'H1048

MSE 300

355

364

6386

337

HSE 250

1679

1679

'H1057

'H1057

MSE 500

355

364

6386

337

HSE 300

1688

1688

'H1066

'H1066

MSE 750

436

364

6281

4461

HSE 350

1688

1688

'H1066

'H1066

MSE 1005

436

364

6281

4461

HSE 400

2290

2290

'H1921

'H1921

*MSE 1500

445

2584

5752

4104

HSE 450

2290

2290

'H1921

'H1921

*MSE 2005

1723

2953

5752

4104

HSE 500

2290

2290

'H1921

'H1921

*MSE 2505

1723

2953

5752

4104

*MSE 3006

1723

2953

6467

4104

*MSE 3305

1741

2984

6481

5114

*MSE 4005

1741

2984

6481

5114

*MSE 4505

1741

2984

6481

5114

*MSE 5005

1741

2984

6481

5114

*MSE 6505

111

120

2542

5233

*MSE 7505

111

120

2542

5233

*MSE 100Hp

4092

4092

120

120

*MSE 120Hp

4092

4092

120

120

These chart is to be used for reference purposes only.


For replacement parts contact customer service with your condenser model and
serial numbers.
* Indicates that model is obsolete and no longer manufactured.

MSE models with zinc anode may require a special rear endplate.
Please consult with factory.

26

Rear
Endplate
ENDPL-

Menu
ELT/KHX - Gasket and Endplates Cross Reference

Condensers

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

Rear
Endplate
ENDPL-

Condensers

Front
Gasket
GASKE-

Rear
Gasket
GASKE-

Front
Endplate
ENDPL-

Rear
Endplate
ENDPL-

Condensers

ELT 100A

5057

5064

3055

3073

KH 11/2X

698A

698B

1840

1796

ELT 150A

5057

5064

3055

3073

KH 2X

698A

698B

1840

1796

ELT 200A

5057

5057

3055

3154

KH 3X

698A

698B

1840

1796

ELT 300A

2191

2209

3253

3280

KH 5X

706A

706B

1859

1813

ELT 500A

2191

2209

3253

3280

KH 71/2X

724A

724B

1868

1831

KH 10X

724A

724B

1868

1831

ELT 800A

2461

2470

3451

3482

ELT 1000A

2461

2470

3451

3482

*ELT 50

2092

2100

3046

3064

*ELT 75

2092

2100

3046

3064

*ELT 100

2092

2100

3046

3064

*ELT 150

2092

2100

3046

3064

*ELT 200

2092

2092

3424

3424

*ELT 300

2191

2209

3262

3280

*ELT 500

2191

2209

3262

3280

*ELT 800

2461

2470

3475

3482

*ELT 1000

2461

2470

3475

3482

These chart is to be used for reference purposes only.


For replacement parts contact customer service with your condenser model and
serial numbers.
* Indicates that model is obsolete and no longer manufactured.

27

Menu
Condensers Gaskets ID

Condensers

111
12 3/4" Dia.
12 Studs

12 3/4" Dia.
12 Studs

175
6" Dia.
4 Studs

184
6" Dia.
4 Studs

193
6 5/8" Dia.
6 Studs

201

28

6 5/8" Dia.
12 Studs

8 5/8" Dia.
6 Studs

166

355

229

120

6 5/8" Dia.
6 Studs

5" Dia.
4 Studs

8 5/8" Dia.
6 Studs

12 3/4" Dia.
12 Studs

346

210

364

238
6 5/8" Dia.
6 Studs

8 5/8" Dia.
6 Studs

373

247
10 3/4" Dia.
9 Studs

8 5/8" Dia.
6 Studs

382

256
6 5/8" Dia.
6 Studs

10 3/4" Dia.
9 Studs

436

265
6 5/8" Dia.
6 Studs

10 3/4" Dia.
9 Studs

445

337
5" Dia.
4 Studs

8 5/8" Dia.
12 Studs

Menu
Condensers Gaskets ID

Condensers

698A

1750

1480
10 3/4" Dia.
9 Studs

12 3/4" Dia.
12 Studs

698B

706A

2074

1499
Tube-in-tube gasket
no picture available

14" Dia.
12 Studs

2083
706B

Tube-in-tube gasket
no picture available

2092

1679
724A

1 3/16" x 9 1/16"

19 11/16"
Dia.

2100
1 3/16" x 6 5/16"

724B
1688
1057
6 5/8" Dia.
6 Studs

2191

21 11/16"
Dia.

2 9/16" x 15 3/4"

2209
2 9/16" x 15 3/4"

1723
1066
6 5/8" Dia.
6 Studs

8 5/8" Dia.
6 Studs

2254
14 11/16"
Dia.

1732
1462
10 3/4" Dia.
12 Studs

8 5/8" Dia.
6 Studs

2263
16 11/16"
Dia.

1741
1471
8 5/8" Dia.
12 Studs

10 3/4" Dia.
9 Studs

2290
25" Dia.

29

Menu
Condensers Gaskets ID

Condensers

2461
3 1/4" x 20 1/4"

3718

3101
6 5/8" Dia.
6 Studs

6 5/8" Dia.
6 Studs

2470
3 1/4" x 13 1/2"

5057

3118
2584

1 3/16" x 9 1/16"

8 5/8" Dia.
6 Studs

8 5/8" Dia.
6 Studs

3149
2591

6" Dia.
4 Studs

2953

5" Dia.
4 Studs

8 5/8" Dia.
6 Studs

3156

8 5/8" Dia.
6 Studs

3163
2977

6" Dia.
4 Studs

8 5/8" Dia.
6 Studs

3170
2984
10 3/4" Dia.
9 Studs

30

6 5/8" Dia.
6 Studs

Menu
Condensers Front Endplate ID

Condensers

193

12
10 3/4" Dia.
9 Studs

8 1/2" Dia.
6 Studs

12 3/4" Dia.
12 Studs

28" Dia.

6" Dia.
4 Studs

8 5/8" Dia.
6 Studs

8 5/8" Dia.
12 Studs

17 7/8" Dia

2092
8 5/8" Dia.
12 Studs

H1048

148
19 7/8" Dia.

10 3/4" Dia.
9 Studs

2065

H1039

120
8 5/8" Dia.
6 Studs

1499
6 5/8" Dia.
6 Studs

706

85
6 5/8" Dia.
6 Studs

H1921

328

67
6" Dia.
4 Studs

2119
10 3/4" Dia.
12 Studs

H1057

175
8 5/8" Dia.
6 Studs

24" Dia.

247

49
5" Dia.
14 Studs

H1066

22" Dia.

2137
12 3/4" Dia.
12 Studs

31

Menu
Condensers

Condensers Front Endplate ID

2155
14" Dia.
16 Studs

2227

2236

8 5/8" Dia.
6 Studs

2263

10 3/4" Dia.
9 Studs

2939

2533
10 3/4" Dia.
9 Studs

12 3/4" Dia.
12 Studs

2452
6 5/8" Dia.
6 Studs

2920

2524
12 3/4" Dia.
12 Studs

8 5/8" Dia.
6 Studs

2911

2506

2245

3334

2542
8 5/8" Dia.
6 Studs

12 3/4" Dia.
12 Studs

2461

32

8 5/8" Dia.
6 Studs

10 3/4" Dia.
9 Studs

12 3/4" Dia.
12 Studs

2894

2489
8 5/8" Dia.
6 Studs
OBSOLETE

10 3/4" Dia.
9 Studs

8 5/8" Dia.
6 Studs

8 5/8" Dia.
6 Studs

8 5/8" Dia.
6 Studs

8 5/8" Dia.
6 Studs

2876

2470

3868

2678
8 5/8" Dia.
6 Studs

12 3/4" Dia.
12 Studs

Menu
Condensers Front Endplate ID

Condensers

3901
8 5/8" Dia.
9" Studs

4261
10 3/4" Dia.
9 Studs

3918
8 5/8" Dia.
6" Studs

4278

3956

12 3/4" Dia.
12 Studs

4292

4328

5707
8 5/8" Dia.
6 Studs

5040

4230
6" Dia.
4 Studs

5727
8 5/8" Dia.
6 Studs

5464

4247
10 3/4" Dia.
9 Studs

8 5/8" Dia.
6 Studs

5583
10 3/4" Dia.
9 Studs

6" Dia.
4 Studs

6 5/8" Dia.
6 Studs

5576
8 5/8" Dia.
6 Studs

10 3/4" Dia.
9 Studs

4092

5819
6 3/4" Dia.
6 Studs

5495

4254
8 5/8" Dia.
6 Studs

6 5/8" Dia.
6 Studs

10 3/4" Dia.
9 Studs

8 5/8" Dia.
6 Studs

5552

8 5/8" Dia.
6 Studs

5907
10 3/4" Dia.
9 Studs

33

Menu
Condensers

Condensers Front Endplate ID

6436

5938
6" Dia.
4 Studs

8 5/8" Dia.
6 Studs

6487

6205
8 5/8" Dia.
6 Studs

10 3/4" Dia.
9 Studs

6481

6229
10 3/4" Dia.
9 Studs

6 3/4" Dia.
6 Studs

6605

6281
8 5/8" Dia.
6 Studs

6 5/8" Dia.
6 Studs

6717

6389
6" Dia.
4 Studs

6 5/8" Dia.
6 Studs

6412
5 1/4" Dia.
4 Studs

34

Menu
Evaporators

Design Features and Ratings


Conformance
TX/TXC

Standard chiller barrels 6" and smaller OD shell are U.L. listed.
Models with 6 5/8" and larger shell are constructed to ASME Boiler and Pressure Vessel Code
Section VIII, Div. 1.

ERS/ERD

ERS/ERD Models are rated at 300 psi tube side and 200 psi shell side (non-code). Each model is
tested before shipment and ratings are developed through extensive laboratory testing and computer
modeling.

Nominal Tonnage Rating Basis


Nominal ratings are based on ARI standard 480, specific conditions being:
1 ton = 12,000 Btu/hr
54F inlet water

100F liquid entering TXV

7F superheat

44F outlet water 35F R22 Saturated Suction (R410A on -410 models)
0.0001 ft2 hrF/Btu fouling factor
AlfaChill
(EVP-ACH)

AlfaNova
(EVP-AN)

Sizing by Nominal Tons


Sizing by nominal tons is done according to ARI standards. Chillers can be selected on a nominal
system tons basis, as shown in the catalog, or reflected in the model name. For example, a TXC502
is a nominal 50 ton dualcircuit barrel. This method is reasonably accurate for sizing airconditioning
systems. However, it is not recommended for evaporating temperature below 34 F, or when the
fluids used are other than water and R22. All heat exchangers have capacity limits and careless
sizing of chiller barrels leads to needless performance problems. Undersizing can lead to insufficient
cooling and inefficient compressor operation. Oversizing can lead to control valve hunting, poor
performance, oil logging, and refrigerant slugging. When your application varies from nominal airconditioning conditions, such as brine, low-temperature and process cooling applications, utilize
StanrefPro selection software or evaporator performance tables, which can be obtained at www.
stanref.com or from customer service.

Limitations
1. For cooling water applications a minimum evaporating temperature of 32F should be maintained
in the evaporator to prevent freezing.
2. Maximum water entering temperature of 70F.
3. Minimum outgoing water temperature of 36F.
4. Minimum approach 5 (for approaches 6F or less, system should be designed to insure proper
oil return).
Note: For brine, low temperature and special design applications, please consult factory.
Note: Do not exceed maximum stated flow rate.

Technical Assistance and Custom Designs


Standard offers custom design services and computer performance projections on all heat exchange
products to help you match product and application accurately. You are invited to contact your
nearest sales representative or our office headquarters for prompt assistance.
To download sizing and selection software, visit www.stanref.com/StanRefPro/setup.exe

35

Menu
Evaporator Sizing

Selecting the proper chiller barrel for your application depends


on four basic sizing considerations:

Range
The desired temperature drop of the fluid measured as the
difference between incoming and outgoing fluid temperatures.

Approach
The desired temperature difference between outgoing fluid and
the refrigerant evaporating temperature.

Pressure Drop

Range x gpm x 500 = Btu/hr


Another sizing method is by compressor capacity. Manufacturer
curves showing compressor Btu/hr values serve as a simple
guideline for selecting chiller barrels for a given system.
Also, Standard chiller barrels are rated to ARI standards
and can be selected on a nominal system tons basis using
the capacity charts in this catalog. This method, however,
is recommended only for high temperature (air conditioning)
systems.

Fluid Nozzle Location (Shell and Tube only)

Acceptable level of fluid pressure drop through the chiller barrel


at computed gallons per minute (gpm) flow rate.

The standard fluid nozzle location is on the right as you are


facing the refrigerant connections. Special top, and left side
connections can be ordered.

Capacity

TX2 through TX20 have top side nozzle location as standard.

Necessary heat removal (tonnage) at maximum operating load

Technical Assistance and Custom Designs

Determine the range and approach then obtain the StanrefPro


selection and rating software at our website www.stanref.com.

Standard offers custom design services and computer


performance projections on all heat exchange products to
help you match product and application accurately. You are
invited to contact your nearest sales representative or our office
headquarters for prompt assistance.

Chiller barrels may be sized by other methods as well. Where


the desired temperature range is known (difference between
incoming and outgoing fluid), determine the Btu/hr capacity
needed by multiplying the temperature range by gpm flow and
convert to pounds of water per hour using the multiplier 500.

36

Menu
Selecting the Right Evaporator
Sizing the Right Evaporator (Chiller Barrel)
Sizing by Nominal Tons
There are three basic selection methods you can use to size a
chiller barrel. The first and easiest is to size by nominal system
tons. The second method is to use compressor capacity. The
third and recommended method is sizing by range, flow and
approach.
Sizing by nominal tons is done according to ARI standards.
Chiller barrels can be selected on a nominal system ton basis,
as shown in the catalog model specifications, or it can be
reflected in the model name. For example, a TXC50-2 is a
nominal 50 ton dual-circuit chiller barrel.
Nominal ton ratings are based on the conditions of ARI
Standard 480 utilizing R-22, which are:
54F water in

You may also size by compressor capacity. Compressor


manufacturer performance data of Btu per hour can be used
to select chiller barrels for a given system. By reading the
performance curves of the compressor at the conditions that
you require, you can determine the maximum capacity chiller
barrel you will need.

Sizing by Range and Flow


The most precise way to size a chiller barrel when water is used
is by the range and flow rate as seen in the formula:

Btu/hr capacity = Range x gpm x 500


Btu/hr capacity
=

44F water out


35F refrigerant evaporating temperature 7F superheat
0.001 hr-ft-F/Btu
100F liquid refrigerant entering the flow control
This method is reasonably accurate for sizing air conditioning
systems, or high back pressure systems. However, it is not
recommended for evaporating temperatures below 34F, or
when the fluids used are other than water and R-22.

AHRI standard
54F water inlet
44F water outlet
35F water inlet
7F superheat
0.0001 hr-ft-F/Btu
100F liquid refrigerant

Sizing by Compressor Capacity

Range x gpm x 500


To obtain the Btu per hour capacity, just multiply the Range
or Temperature Drop by gpm flow, and convert to pounds of
water per hour by multiplying by 500. The Btu's can then be
divided by 12,000 to yield the tons of load.
With an incoming water temperature of 55F, outgoing water
temperature of 45F, and a 479 gpm water flow. Btu capacity
can be calculated like this:
(55 - 45) x 479 gpm x 500 = 2,395,000 Btu/hr
2,395,000 Btu/hr (divided by)
12,000 Btu/ton = 199.5 tons
In cases where the fluid being cooled is other than water,
capacity can be determined by adding the
specific heat and specific gravity into the equation: Btu/hr =
Range x gpm x 500 x Sp Heat x Sp Gravity
This equation will give you the capacity required, but chiller
selection should be made by your factory representative since
the fluid is not water.
All of the Standard rating data is based on ARI standards, a
suction temperature 35F, using water as the fluid. Contact an
Alfa Laval representative for special fluid conditions.
All heat exchangers have capacity limits. Careless sizing of
chiller barrels leads to needless performance problems.
Undersizing can lead to insufficient cooling and inefficient
compressor operation.
Oversizing can lead to control valve hunting, poor performance,
oil logging, and refrigerant slugging.

37

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable Replacement Series 1-Circuit

Evaporators

1-Circuit
Compact Serviceable Chiller Barrels, Design Features and Ratings
Models

R-22
Nominal
Capacity*

R-134a
Nominal
Capacity*

R-22
Pressure
Drop

R-134a
Pressure
Drop

Connections

Fluid
Volume

Specifications

Working
Pressure (psig)

(TR)

(TR)

(psi)

(psi)

P
Ref. In
(ids)

Q
Ref. Out
(ids)

W
Fluid Conn.

T
Drain
(fpt)

(gal)

Tube
Length
(inches)

Shell
Diameter
(inches)

Shipping
Weight
(lbs)

Shell
Side

Tube
Side

TX2 -1

2.0

1.8

2.7

2.2

5/8

7/8

1" FPT

3/8

0.4

24

2 3/4

46

225

225

TX3 -1

2.9

2.3

2.1

1.4

5/8

7/8

1" FPT

3/8

0.4

24

2 3/4

50

225

225

TX5 -1

4.9

4.0

2.5

1.7

5/8

1 1/8

1 1/4" FPT

1/2

1.6

36

62

225

225

TX6 -1

6.7

5.4

3.3

2.2

5/8

1 1/8

1 1/2" FPT

1/2

1.5

36

64

225

225

TX7 1/2 -1

7.6

6.3

3.9

2.7

7/8

1 5/8

1 1/2" FPT

1/2

1.4

36

66

225

225

TX10 -1

11.3

9.2

6.0

3.9

7/8

1 5/8

2" FPT

1/2

1.2

36

70

225

225

TX12 -1

14.3

11.6

3.8

2.6

7/8

1 5/8

2" FPT

1/2

3.4

36

120

225

225

TX15-1

18.3

14.8

5.4

3.6

1 1/8

2 1/8

2 1/2" FPT

1/2

3.2

36

128

225

225

TX20-1

22.6

18.4

5.8

3.9

1 1/8

2 1/8

3" FPT

1/2

2.9

36

136

225

225

TX25 -1

27.2

22.0

6.1

4.0

1 1/8

2 5/8

3" FPT

1/2

2.6

36

142

150

225

TXC30 -1

24.5

29.9

5.3

3.7

1 1/8

2 5/8

3" MPT

3/4

9.3

72

6 5/8

414

150

300

TXC40 -1

32.6

40.2

4.8

3.2

1 3/8

2 5/8

3" MPT

3/4

17.5

72

8 5/8

563

150

300

TXC50 -1

40.7

50.9

5.3

3.4

1 3/8

3 1/8

4" FLANGE

3/4

17.1

72

8 5/8

594

150

300

TXC60 -1

47.7

59.7

4.3

2.8

1 5/8

3 1/8

4" FLANGE

3/4

19.8

84

8 5/8

642

150

300

TXC75 -1

59.5

75.2

5.1

3.2

2 1/8

3 1/8

5" FLANGE

3/4

19.5

84

8 5/8

587

150

300

TXC100-1

79.8

100.4

6.1

3.9

2 1/8

3 5/8

5" FLANGE

3/4

28.4

84

10 3/4

1070

150

225

TXC120-1

98.7

123.4

5.2

3.4

2 1/8

3 5/8

6" FLANGE

3/4

26.9

84

12 3/4

1080

150

225

*Nominal ratings: Include an additive fouling coefficient of 0.0001 ft2 hrF/Btu over clean rating per AHRI standard 480-2007
Standard Refrigeration software values are the most accurate
TR = 12,000 Btu/hr

Serviceable
30% - 50% smaller than comparable models
Easier to handle and position
New advanced design
UL listed or ASME

Models

38

34" insulation
Single and dual-circuit designs
3 and 4 circuit designs available
39 TX/TXC models from 2 through 500 tons
Ideal for OEM and System Builder replacements

Dimensions (inches)
H

TX2-1

6 1/16

28 1/4

2 1/8

21 7/8

3 1/2

23 1/2

1/2

2 1/2

2 1/2

3 7/8

3/4

11/16

9/16

TX3-1

6 1/16

28 1/4

2 1/8

21 7/8

3 1/2

23 1/2

1/2

2 1/2

2 1/2

3 7/8

3/4

11/16

9/16

TX5-1

8 3/4

40 1/4

2 5/16

33 11/16

3 1/2

35 1/2

1/2

3 1/2

15/16

3/4

9/16

TX6-1

40 1/4

2 7/16

33 9/16

3 1/2

35 1/2

1/2

3 1/2

15/16

3/4

9/16

TX7 -1

40 1/4

2 7/16

33 9/16

3 1/2

35 1/2

1/2

3 1/2

1 1/16

15/16

9/16

TX10-1

40 1/4

2 13/16

33 3/16

3 1/2

35 1/2

1/2

3 1/2

1 1/16

15/16

9/16

TX12-1

10

41 1/4

2 15/16

33 1/16

4 1/2

35 1/2

1/2

5 3/4

1 3/16

15/16

9/16

TX15-1

10 5/16

41 1/4

3 3/16

32 13/16

4 1/2

35 1/2

1/2

5 3/4

1 1/2

9/16

TX20-1

11

41 1/4

3 1/2

32 1/2

4 1/2

35 1/2

1/2

5 3/4

1 1/2

9/16

TX25-1

11

41 1/4

3 1/2

32 1/2

4 1/2

35 1/2

1/2

5 3/4

1 1/2

1 1/4

9/16

TXC30-1

12 1/2

81 3/4

4 1/4

67 3/4

36

18

5 1/4

1 3/4

1 3/4

9/16

TXC40-1

14 1/2

81 3/4

4 1/2

67 1/2

36

18

7 1/8

2 1/8

1 2/3

9/16

TXC50-1

15 1/2

81 3/4

4 3/4

67 1/4

36

18

7 1/8

2 1/4

2 3/8

9/16

TXC60-1

14 1/2

93 3/4

4 3/4

79 1/4

42

21

7 1/8

2 1/4

2 3/8

9/16

TXC75-1

15 1/2

93 3/4

5 1/2

78 1/2

42

21

7 1/8

2 1/4

2 3/8

9/16

TXC100-1

19 5/8

95 1/8

5 3/4

78 1/4

8 3/8

42

21

4 1/2

10 1/4

2 3/4

2 3/8

9/16

TXC120-1

19 2/3

94 7/8

6 3/8

77 5/8

8 3/8

42

21

11 1/4

3 4/9

2 3/4

9/16

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable Replacement Series 1-Circuit

Evaporators

TX
1-Circuit

TXC
1-Circuit

39

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable Replacement Series 2-Circuit

Evaporators

2-Circuit and Multi-Circuit - Compact Serviceable Chiller Barrels, Design Features and Ratings
Models

R-22
Nominal
Capacity*

R-134a
Nominal
Capacity*

R-22
Pressure
Drop

R-134a
Pressure
Drop

Connections

Fluid
Volume

Specifications

(TR)

(TR)

(psi)

(psi)

P
Ref. In
(ids)

Q
Ref. Out
(ids)

W
Fluid Conn.

T
Drain
(fpt)

(gal)

Tube
Length
(inches)

Shell
Diameter
(inches)

Working
Pressure (psig)
Shipping
Weight
(lbs)

Shell
Side

Tube
Side

TX10-2

11

6.0

3.9

5/8

1 1/8

2" FPT

1/2

1.2

36

70

225

225

TX12-2

14

12

3.8

2.6

5/8

1 1/8

2" FPT

1/2

3.4

36

120

225

225

TX15-2

18

15

5.4

3.6

7/8

1 5/8

2 1/2" FPT

1/2

3.2

36

128

225

225

TX20-2

23

18

5.8

3.9

7/8

1 5/8

3" FPT

1/2

2.9

36

136

225

225

TX25-2

27

22

6.1

4.0

7/8

1 5/8

3" FPT

1/2

2.6

36

142

150

225

TXC30-2

25

30

5.3

3.7

7/8

1 5/8

3" MPT

3/4

9.3

72

6 5/8

404

150

300

TXC40-2

33

40

4.8

3.2

1 1/8

2 1/8

3" MPT

3/4

17.5

72

8 5/8

556

150

300

TXC50-2

41

51

5.3

3.4

1 1/8

2 1/8

4" FLANGE

3/4

17.1

72

8 5/8

581

150

300

TXC60-2

48

60

4.3

2.8

1 1/8

2 5/8

4" FLANGE

3/4

19.8

84

8 5/8

634

150

300

TXC75-2

60

75

5.1

3.2

1 3/8

2 5/8

5" FLANGE

3/4

19.5

84

8 5/8

587

150

300

TXC100-2

80

100

6.1

3.9

1 3/8

3 1/8

5" FLANGE

3/4

28.4

84

10 3/4

1070

150

225

TXC120-2

99

123

5.2

3.4

1 3/8

3 1/8

6" FLANGE

3/4

26.9

84

12 3/4

1080

150

225

TXC150-2

123

154

6.7

4.3

1 3/8

3 1/8

6" FLANGE

3/4

34

84

14

1600

150

225

TXC175-2

143

181

6.7

4.3

1 5/8

3 1/8

6" FLANGE

3/4

31

84

16

1700

150

225

TXC200-2

169

212

5.2

3.4

1 5/8

3 1/8

8" FLANGE

3/4

42

84

16

2100

150

225

TXC250-2

198

247

5.6

3.6

2 1/8

3 5/8

8" FLANGE

3/4

39

84

18

2200

150

225

TX15-3

18

15

5.4

3.6

5/8

1 1/8

2 1/2" FPT

1/2

8.4

72

145

225

225

TX20-4

23

18

5.8

3.9

5/8

1 1/8

3" FPT

1/2

8.1

72

155

225

225

Multi-Circuit

*Nominal ratings: Include an additive fouling coefficient of 0.0001 ft2 hrF/Btu over clean rating per AHRI standard 480-2007
Standard Refrigeration software values are the most accurate
TR = 12,000 Btu/hr

Serviceable
30% - 50% smaller than comparable models
Easier to handle and position
New advanced design
UL listed or ASME

Models

34 insulation
Single and dual-circuit designs
3 and 4 circuit designs available
39 TX/TXC models from 2 through 500 tons
Ideal for OEM and System Builder replacements

Dimensions (inches)
H

TX10-2

40 1/2

2 13/16

33 3/16

3 1/2

35 1/2

1/2

3 1/2

11/16

15/16

3/4

9/16

TX12-2

10

41 1/4

2 15/16

33 1/16

4 1/2

35 1/2

1/2

5 3/4

3/4

1 1/8

1 1/8

9/16

TX15-2

10 1/3

41 1/4

3 3/16

32 13/16

4 1/2

35 1/2

1/2

5 3/4

1 3/16

7/8

1 1/4

1 1/4

9/16

TX20-2

11

41 1/4

3 1/2

32 1/2

4 1/2

35 1/2

1/2

5 3/4

1 3/16

7/8

1 1/4

1 1/4

9/16

TX25-2

11

41 1/4

3 1/2

32 1/2

4 1/2

35 1/2

1/2

5 3/4

1 3/16

7/8

1 1/4

1 1/4

9/16

TXC30-2

12 1/2

81 3/4

4 1/4

67 3/4

54

18

5 1/4

1 1/2

1 1/2

1 3/4

1 3/4

9/16

TXC40-2

14 1/8

81 3/4

4 1/2

67 1/2

54

18

7 1/8

1 3/4

1 5/8

9/16

TXC50-2

14 1/8

81 3/4

4 3/4

67 1/4

54

18

7 1/8

1 3/4

1 5/8

9/16

TXC60-2

15 1/2

93 3/4

4 3/4

79 1/4

63

21

7 1/8

1 3/4

1 5/8

9/16

TXC75-2

15 1/2

93 3/4

5 1/2

78 1/2

63

21

7 1/8

1 3/4

1 5/8

9/16

TXC100-2

16 7/8

95 1/8

5 3/4

78 1/4

8 5/8

63

21

4 1/2

11 1/4

2 3/8

2 2/3

2 1/4

3 1/8

9/16

TXC120-2

19 5/8

94 7/8

6 3/8

77 5/8

8 3/8

63

21

11 1/4

2 3/8

2 2/3

2 1/4

3 1/2

9/16

TXC150-2

20 7/8

96 5/8

6 3/8

77 5/8

9 3/8

63

21

5 1/2

12

2 5/8

2 1/8

11/16

TXC175-2

24

96 5/8

6 3/8

77 5/8

9 3/8

63

21

5 1/2

12

2 5/8

2 3/4

3 1/3

3 1/3

11/16

TXC200-2

24

96 5/8

7 1/2

76 1/2

9 3/8

63

21

5 1/2

12

2 5/8

2 3/4

2 1/2

3 1/3

11/16

TXC250-2

26

96 5/8

7 1/2

76 1/2

9 3/8

63

21

5 1/2

12

3 1/2

2 1/2

3 3/4

11/16

Multi-Circuit
TX15-3 and TX20-4

40

Note: Multi-circuit model drawings on request.

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable

Evaporators

TX
2-Circuit

Other multi-circuit models available, consult with factory.


Dimensions do not include the 3/4" factory insulation.

TXC
2-Circuit

Dimensions do not include the 3/4" factory insulation.

41

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable R410A 1-Circuit

Evaporators

Compact Serviceable Chiller Barrels, Design Features and Ratings 1-Circuit


High refrigerant pressure rating and performance optimized for use with R410A
Models

R-410a
Nom'l
Cap.*

R-410a
Pressure
Drop

Connections

Fluid
Volume

Specifications

Working
Pressure
(psig)

(TR)

(TR)

P
Ref. In
(ids)

Q
Ref. Out
(ids)

W
Fluid
Conn.

T
(fpt)

(gal)

Tube
Length
(inches)

D-Shell
Shell Diameter
(inches)

Shipping
Weight
(lbs)

Shell
Side

Tube
Side

TX2-1-410

2.0

1.7

3/8

5/8

1" FPT

3/8

0.4

36

2 3/4

46

225

375

TX3-1-410

3.1

2.7

3/8

7/8

1" FPT

3/8

0.4

36

2 3/4

50

225

375

TX5-1-410

5.0

2.4

5/8

7/8

1.25" FPT

1/2

1.6

36

62

225

375

TX6-1-410

6.0

2.6

5/8

7/8

1.5" FPT

1/2

1.5

36

64

225

375

TX7 -1-410

7.5

3.0

5/8

1 1/8

1.5" FPT

1/2

1.4

36

66

225

375

TX10-1-410

10.2

4.0

5/8

1 1/8

2" FPT

1/2

1.2

36

70

225

375

TX12-1-410

12.0

5.0

7/8

1 3/8

2" FPT

1/2

3.4

36

120

225

375

TX15-1-410

15.1

5.2

7/8

1 3/8

2.5" FPT

1/2

3.2

36

128

225

375

TX20-1-410

19.7

5.9

7/8

1 5/8

2.5" FPT

1/2

2.9

36

136

225

375

TX25-1-410

25.0

4.7

7/8

1 5/8

3" FPT

1/2

2.6

36

142

225

375

TXC30-1R410

30.0

5.1

1 1/8

2 1/8

3" MPT

3/4

9.4

72

6 5/8

414

150

375

TXC40-1R410

40.0

4.9

1 1/8

2 1/8

3" MPT

3/4

17.7

72

8 5/8

563

150

375

TXC50-1R410

50.0

4.4

1 3/8

2 1/8

4" FLG

3/4

17.3

72

8 5/8

594

150

375

TXC60-1R410

60.0

6.0

1 3/8

2 5/8

4" FLG

3/4

20.1

84

8 5/8

642

150

375

TXC75-1R410

75.0

6.8

1 5/8

3 1/8

5" FLG

3/4

19.8

84

8 5/8

587

150

375

TXC100-1R410

100.0

5.7

2 1/8

3 1/8

5" FLG

3/4

28.8

84

10 3/4

1070

150

375

TXC120-1R410

120.0

4.5

2 1/8

3 5/8

6" FLG

3/4

27.2

84

12 3/4

1080

150

375

*Nominal ratings: Include an additive fouling coefficient of 0.0001 ft2 hrF/Btu over clean rating per AHRI standard 480-2007
Standard Refrigeration software values are the most accurate
TR = 12,000 Btu/hr

Serviceable
30% - 50% smaller than comparable models
Easier to handle and position
New advanced design
UL listed or ASME

Models

42

34 insulation
Single and dual-circuit designs
Custom DX designs available to 800 tons
33 TX/TXC-410 models from 2 through 200 tons
Ideal for OEM and System Builder applications
Dimensions (inches)

TX2-1-410

6 1/4

40 1/4

2 1/8

33 7/8

3 1/2

35 1/2

1/2

2 1/2

2 1/2

3 7/8

3/4

11/16

9/16

TX3-1-410

6 1/8

40 1/4

2 1/8

21 7/8

3 1/2

23 5/8

1/2

2 1/2

2 1/2

3 7/8

3/4

11/16

9/16

TX5-1-410

40 3/4

2 1/3

33 2/3

3 3/4

35 1/4

3/4

2 1/2

3 1/2

15/16

3/4

9/16

TX6-1-410

40 3/4

2 4/9

33 5/9

3 3/4

35 1/4

3/4

2 1/2

3 1/2

15/16

3/4

9/16

TX7 -1-410

40 3/4

2 4/9

33 5/9

3 3/4

35 1/4

3/4

2 1/2

3 1/2

1 1/16

15/16

9/16

TX10-1-410

40 1/4

2 4/5

33 1/5

3 3/4

35 1/4

3/4

2 1/2

3 1/2

1 1/16

15/16

9/16

TX12-1-410

10

42 1/4

33

35.25

3/4

5 3/4

1 3/16

15/16

9/16

TX15-1-410

11

42 1/4

3 1/5

32 1/6

35.25

3/4

5 3/4

1 1/2

9/16

TX20-1-410

11

42 1/4

3 1/5

32 1/6

35.25

3/4

5 3/4

1 1/2

9/16

TX25-1-410

11

41 1/4

3 3/4

32 1/4

35.25

3/4

5 3/4

1 1/2

1 1/4

9/16

TXC30-1R410

12 3/8

81 1/2

4 1/4

67 3/4

54

18

5 1/4

1 3/4

1 3/4

9/16

TXC40-1R410

14

81 3/4

4 1/2

67 3/4

54

18

7 1/8

2 1/8

1 2/3

9/16

TXC50-1R410

14

81 3/4

4 1/2

67 3/4

54

18

7 1/8

2 1/4

2 3/8

9/16

TXC60-1R410

17 1/2

93 3/4

4 3/4

79 1/4

63

21

7 1/8

2 1/4

2 3/8

9/16

TXC75-1R410

18 1/2

93 3/4

5 1/2

78 1/2

63

21

7 1/8

2 1/4

2 3/8

9/16

TXC100-1R410

16 1/4

95 1/8

5 1/2

78 1/2

8 5/8

63

21

3 1/2

9 1/4

2 3/4

2 3/8

9/16

TXC120-1R410

18 4/7

94 7/8

6 3/8

77 5/8

8 3/8

63

21

3 1/2

11 1/4

3 4/9

2 3/4

9/16

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable R410A 1-Circuit

Evaporators

TX - R410A
1-Circuit

TXC-R410A
1-Circuit

43

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable R410A 2-Circuit

Evaporators

Compact Serviceable Chiller Barrels, Design Features and Ratings 2-Circuit and Multi-Circuit
High refrigerant pressure rating and performance optimized for use with R410A
Models

R-410a
Nom'l
Cap.*

R-410a
Pressure
Drop

Connections

Fluid
Volume

Specifications

Working
Pressure
(psig)

(TR)

(TR)

P
Ref. In
(ids)

Q
Ref. Out
(ids)

W
Fluid
Conn.

T
(fpt)

(gal)

Tube
Length
(inches)

D-Shell
Shell Diameter
(inches)

Shipping
Weight
(lbs)

Shell
Side

Tube
Side

TX10-2R410

10

4.0

5/8

7/8

2" FPT

1/2

1.2

36

70

225

375

TX12-2R410

12

5.0

5/8

1 1/8

2" FPT

1/2

3.4

36

120

225

375

TX15-2R410

15

5.2

5/8

1 1/8

2.5" FPT

1/2

3.2

36

128

225

375

TX20-2R410

20

5.9

5/8

1 1/8

2.5" FPT

1/2

2.9

36

136

225

375

TX25-2R410

25

4.7

7/8

1 3/8

3" FPT

1/2

2.6

36

142

225

375

TXC30-2R410

30

5.1

7/8

1 3/8

3" MPT

3/4

9.4

72

6 5/8

404

150

375

TXC40-2R410

40

4.9

7/8

1 5/8

3" MPT

3/4

17.7

72

8 5/8

556

150

375

TXC50-2R410

50

4.4

1 1/8

1 5/8

4" FLG

3/4

17.3

72

8 5/8

581

150

375

TXC60-2R410

60

6.0

1 1/8

1 5/8

4" FLG

3/4

20.1

84

8 5/8

634

150

375

TXC75-2R410

75

6.8

1 3/8

2 1/8

5" FLG

3/4

19.8

84

8 5/8

587

150

375

TXC100-2R410

100

5.7

1 3/8

2 1/8

5" FLG

3/4

28.8

84

10 3/4

1070

150

375

TXC120-2R410

120

4.5

1 3/8

2 5/8

6" FLG

3/4

27.2

84

12 3/4

1080

150

375

TXC150-2R410

150

6.4

1 5/8

2 5/8

6" FLG

3/4

34.4

84

14

1600

150

375

TXC175-2R410

175

5.9

1 5/8

3 1/8

6" FLG

3/4

31.4

84

14

1700

150

375

TXC200-2R410

200

4.6

2 1/8

3 1/8

8" FLG

3/4

42.5

84

16

2100

150

375

TX15-3-410

15

7.0

5/8

7/8

2 1/2" FPT

1/2

8.5

36

145

225

375

TX20-4-410

20

6.3

5/8

7/8

2 1/2" FPT

1/2

8.2

36

155

225

375

Multi-Circuit

*Nominal ratings: Include an additive fouling coefficient of 0.0001 ft2 hrF/Btu over clean rating per AHRI standard 480-2007
Standard Refrigeration software values are the most accurate
TR = 12,000 Btu/hr

Serviceable
30% - 50% smaller than comparable models
Easier to handle and position
New advanced design
UL listed or ASME

Models

34 insulation
Single and dual-circuit designs
Custom DX designs available to 800 tons
33 TX/TXC-410 models from 2 through 200 tons
Ideal for OEM and System Builder applications
Dimensions (inches)

TX10-2R410

40 3/4

2 4/5

33 1/9

3 3/4

35 1/4

3/4

3 1/2

11/16

15/16

3/4

9/16

TX12-2R410

10

42 1/4

33

35 1/4

3/4

5 3/4

3/4

1 1/8

1 1/8

9/16

TX15-2R410

11

42 1/4

3 1/5

32 4/5

35 1/4

3/4

5 3/4

1 3/16

7/8

1 1/4

1 1/4

9/16

TX20-2R410

11

42 1/4

3 1/5

32 4/5

35 1/4

3/4

5 3/4

1 3/16

7/8

1 1/4

1 1/4

9/16

TX25-2R410

11

42 1/4

3 3/4

32 1/4

35 1/4

3/4

5 3/4

1 3/16

7/8

1 1/4

1 1/4

9/16

TXC30-2R410

13 1/2

81 1/2

4 1/4

67 3/4

54

18

5 1/4

1 1/2

1 1/2

1 3/4

1 3/4

9/16

TXC40-2R410

15 1/2

81 3/4

4 1/2

67 1/2

54

18

7 1/8

1 3/4

1 5/8

9/16

TXC50-2R410

16 1/2

81 3/4

4 3/4

67 1/4

54

18

7 1/8

1 3/4

1 5/8

9/16

TXC60-2R410

17 1/2

93 3/4

4 3/4

79 1/4

63

21

7 1/8

1 3/4

1 5/8

9/16

TXC75-2R410

18 1/2

93 3/4

5 1/2

78 1/2

63

21

7 1/8

1 3/4

1 5/8

9/16

TXC100-2R410

19 5/8

95 1/8

5 3/4

78 1/4

8 3/8

63

21

3 1/2

11 1/4

2 3/8

2 2/3

2 1/4

3 1/8

9/16

TXC120-2R410

19 5/8

94 7/8

6 3/8

76 1/8

8 3/8

63

21

3 1/2

11 1/4

2 3/8

2 2/3

2 1/4

3 1/2

9/16

TXC150-2R410

20 7/8

95 7/8

6 3/8

76 1/8

8 7/8

63

21

3 1/2

12

2 5/8

2 1/8

11/16

TXC175-2R410

20 7/8

95 7/8

6 3/8

76 1/8

8 7/8

63

21

3 1/2

12

2 5/8

2 3/4

3 1/3

3 1/3

11/16

TXC200-2R410

24 1/8

95 7/8

7 1/2

75

8.88

63 3/4

20 1/4

3 1/2

12

2 5/8

2 3/4

2 1/2

3 1/3

11/16

Multi-Circuit
TX15-3 and TX20-4

44

Note: Multi-circuit model drawings on request

Menu
TX/TXC - Shell-and-Tube Super Compact Serviceable R410A 2-Circuit

Evaporators

TX - R410A
2-Circuit

TXC-R410A
2-Circuit

45

Menu
TXG - Shell-and-Tube Ultra Compact Serviceable 1-Circuit

Evaporators

The TXG is the industry's most compact shell-and-tube evaporator.

TXG 1-Circuit Design Features and Ratings


Models

R-22
Nom'l
Cap.
Tons

R-134a
Nom'l
Cap.
Tons

R-22
Press.
Drop
(psi)

R-134a
Press.
Drop
(psi)

Shell
Dia.
(in)

Dimensions (inches)
A

Connections
(inches)

P
(ids)

S
(fpt)

T
(fpt)

1-Circuit
TXG30-1

29.8

24.2

4.9

3.3

8 5/8

43 1/2

27 1/2

7 4/5

7 4/5

11 7/8

5/8

3/8

0.75

TXG40-1

40.3

32.6

5.8

3.8

10 3/4

43 1/2

27 1/2

8 7/8

8 7/8

7 1/8

14 1/4

7/8

3/8

0.75

TXG50-1

50.1

40.8

6.8

4.6

10 3/4

43 1/2

26 1/2

8 7/8

8 7/8

7 1/8

14 1/4

1 1/8

1/2

TXG60-1

59.9

48.5

5.6

3.7

12 3/4

43 1/2

26 1/2

9 7/8

9 7/8

8 4/9

16 7/8

1 3/8

1/2

1 1/4

TXG70-1

69.8

56.7

6.2

4.1

12 3/4

43 1/2

25 4/9

9 7/8

9 7/8

8 4/9

16 7/8

1 3/8

1/2

1 1/4

TXG85-1

84.2

68.3

4.0

2.7

14

44 1/2

25 4/9

11 1/2

11 1/2

17 7/8

1 5/8

1/2

TXG100-1

100.6

81.8

5.6

3.8

16

45

25 4/9

12 1/2

12 1/2

10

20 1/8

1 5/8

1/2

TXG115-1

116.1

93.2

5.7

3.7

16

45

24 3/8

12 1/2

12 1/2

10

20 1/8

2 1/8

1/2

TXG130-1

129.1

105.3

6.4

4.4

18

45 1/2

24 3/8

13 1/2

13 1/2

11 1/8

22 1/4

2 1/8

1/2

2 1/2

TXG150-1

151.2

118.8

6.7

4.2

18

51

30 3/8

13 1/2

13 1/2

11 1/8

22 1/4

2 1/8

1/2

TXG190-1

189.4

151.6

3.8

2.5

20

51

28 3/8

14 1/2

14 1/2

12 1/8

24 1/4

2 5/8

1/2

Flanged Connections available on request


Insulation available on request
*Nominal ratings: Include an additive fouling coefficient of 0.0001 ft2 hrF/Btu over clean rating per AHRI standard 480-2007
Standard Refrigeration software values are the most accurate
TR = 12,000 Btu/hr

Shell Side Working Pressure: 225 psi @ 150F


Tube Side:
150 psi @ 150F (Non-Code)

Single and dual-circuit designs


Accurate ratings to AHRI 480-95
22 TXG models from 30 to 190 tons
More resistant to localized freeze-ups
Ideal for OEM replacements
Design resists clogging and premature failure
Serviceable

Water In

Refrig. Out (Suction)

Water Out
Drain

0.56 (4) Holes


Each Tube
Sheet

TXG 130-1, TXG 150-1


& TXG190-1 Only
F
E

1.00
46

1.00
F

Refrig. In (Liquid) (2)


Req'd

Menu
Evaporators

TXG - Shell-and-Tube Ultra Compact Serviceable 2-Circuit


The TXG is the industry's most compact shell-and-tube evaporator.

TXG - 2-Circuit Design Features and Ratings


Models

R-22
Nom'l
Cap.
Tons

R-134a
Nom'l
Cap.
Tons

R-22
Press.
Drop
(psi)

R-134a
Press.
Drop
(psi)

Shell
Dia.
(in)

TXG30-2

29.8

24.2

4.9

3.3

TXG40-2

40.3

32.6

5.8

TXG50-2

50.1

40.8

6.8

TXG60-2

59.9

48.5

TXG70-2

69.8

56.7

TXG85-2

84.2

68.3

Dimensions (inches)

Connections
(inches)

P
(ids)

S
(fpt)

T
(fpt)

8 5/8

42 2/3

27 1/2

9 4/9

7 4/5

11 7/8

7/8

1 5/8

3.8

10 3/4

42 2/3

27 1/2

9 4/9

8 7/8

7 1/8

14 1/4

7/8

1 5/8

4.6

10 3/4

43

26 1/2

10 1/5

8 7/8

7 1/8

14 1/4

1 1/8

2 1/8

5.6

3.7

12 3/4

43 3/4

26 1/2

10 3/4

9 7/8

8 4/9

16 7/8

1 1/8

2 1/8

6.2

4.1

12 3/4

43 2/3

26

11

9 7/8

8 4/9

16 7/8

1 1/8

2 5/8

4.0

2.7

14

44

26

11

11 1/2

17 7/8

1 3/8

2 5/8

2-Circuit

TXG100-2

100.6

81.8

5.6

3.8

16

44

25 1/2

11 1/5

12 1/2

10

20 1/8

1 3/8

2 5/8

TXG115-2

116.1

93.2

5.7

3.7

16

43 1/3

24 3/8

11 1/8

12 1/2

10

20 1/8

1 3/8

3 1/8

TXG130-2

129.1

105.3

6.4

4.4

18

45

24 3/8

12 1/4

13 1/2

11 1/8

22 1/4

1 5/8

3 1/8

TXG150-2

151.2

118.8

6.7

4.2

18

51

30 3/8

12 1/4

13 1/2

11 1/8

22 1/4

1 5/8

3 1/8

TXG190-2

189.4

151.6

3.8

2.5

20

51 2/3

28 3/8

13 1/2

14 1/2

12 1/8

24 1/4

1 5/8

3 5/8

Flanged Connections available on request


Insulation available on request
*Nominal ratings: Include an additive fouling coefficient of 0.0001 ft2 hrF/Btu over clean rating per AHRI standard 480-2007
Standard Refrigeration software values are the most accurate
TR = 12,000 Btu/hr

Single and dual-circuit designs


Accurate ratings to AHRI 480-95
22 TXG models from 30 to 190 tons
More resistant to localized freeze-ups
Ideal for OEM replacements
Design resists clogging and premature failure
Serviceable

Shell Side Working Pressure: 225 psi @ 150F


Tube Side:
150 psi @ 150F (Non-Code)

Refrig. Out (Suction)


D

(2) Req'd
0.56 (4) Holes
Each Tube
Sheet

A
C

1.00

Refrig. In (Liquid) (2)


Req'd

1.00
F

Water In
Water Out

Drain
47

Menu
Evaporators

EVP-ACH - Copper-Brazed Heat Exchangers R410A - High Efficiency

The EVP-ACH Single-Circuit Evaporators are copper-brazed and feature a built-in distributor.
Optimized for use with refrigerant R410A.
For other refrigerants, please contact Customer Service or your Alfa Laval representative.
Four Frame Sizes
Model

Nominal
Tons1

Description

Part
Number

Connections (ids)
Ref. Liq/
Suction
in/out

Water
In/Out

Dimensions (in.)
Dry Wt.
(lbs.)

Frame Size 12.8" H x 3.7" W (Includes studbolts)


EVP-1M-ACH

"D"

"A"
Liq, Suct,
Water

"B"

"C"

Working Pressure 650 PSIG

ACH-30EQ-10H R52

3287084893

3/8", 7/8"

7/8"

4.2

0.9

0.95

1.54

10.6
10.6

EVP-2M-ACH

ACH-30EQ-20H R52

3287084894

3/8", 7/8"

7/8"

6.2

1.5

0.95

1.54

EVP-3.5M-ACH

3.5

ACH-30EQ-30H S09

3287084895

1/2", 7/8"

7/8"

8.2

2.1

0.95

1.54

10.6

EVP-5M-ACH

ACH-30EQ-40H S09

3287084896

1/2", 7/8"

7/8"

10.2

2.7

0.95

1.54

10.6

EVP-6M-ACH

ACH-30EQ-50H S21

3287084897

5/8", 1-1/8"

1-1/8"

12.2

3.3

0.95

1.54

10.6

EVP-7.5M-ACH

7.5

ACH-30EQ-60H S21

3287084898

5/8", 1-1/8"

1-1/8"

14.2

3.9

0.95

1.54

10.6

Frame Size 20.7" H x 4.4" W (Includes studbolts)


EVP-5L-ACH

ACH-70X-22M S21

Working Pressure 650 PSIG

3287083717

5/8", 1-1/8"

1-1/8"

11.3

3.3

0.95

1.97

18.35

EVP-6L-ACH

ACH-70X-26M S21

3287083718

5/8", 1-1/8"

1-1/8"

12.9

3.7

0.95

1.97

18.35

EVP-7.5L-ACH

7.5

ACH-70X-32M S21

3287083719

5/8", 1-1/8"

1-1/8"

15.3

4.2

0.95

1.97

18.35

EVP-10L-ACH

10

ACH-70X-42M S24

3287083720

5/8", 1-3/8"

1-1/8"

19.3

5.1

0.95

1.97

18.35

EVP-12L-ACH

12

ACH-70X-50M S24

3287083721

5/8", 1-3/8"

1-1/8"

22.5

5.9

0.95

1.97

18.35

EVP-15L-ACH

15

ACH-70X-62M S25

3287083723

5/8", 1-3/8"

1-3/8"

27.3

0.95

1.97

18.35

EVP-20L-ACH

20

ACH-70X-78M R49

3287083725

7/8", 1-3/8"

1-3/8"

33.7

8.4

0.95

1.97

18.35

EVP-25L-ACH

25

ACH-70X-100M R49

3287083727

7/8", 1-3/8"

1-3/8"

42.4

10.4

0.95

1.97

18.35

EVP-15XL-ACH

15

ACH-120EQ-30H S46

3287083729

7/8", 2-1/8"

2-1/8"

45.9

3.3

0.95,1.58,1.58

3.62

20.43

EVP-25XL-ACH

25

ACH-120EQ-46H S62

3287083731

1-1/8", 2-1/8"

2-1/8"

61.4

4.7

0.95,1.58,1.58

3.62

20.43

EVP-30XL-ACH

30

ACH-120EQ-60H S62

3287083732

1-1/8", 2-1/8"

2-1/8"

75

6.1

0.95,1.58,1.58

3.62

20.43

EVP-40XL-ACH

40

ACH-120EQ-76H S62

3287083733

1-1/8", 2-1/8"

2-1/8"

90.5

7.6

0.95,1.58,1.58

3.62

20.43

EVP-45XL-ACH

45

ACH-120EQ-90H S62

3287083734

1-1/8", 2-1/8"

2-1/8"

104.1

8.9

0.95,1.58,1.58

3.62

20.43

EVP-50XL-ACH

50

ACH-120EQ-106H S62

3287083735

1-1/8", 2-1/8"

2-1/8"

119.6

10.4

0.95,1.58,1.58

3.62

20.43

EVP-60XL-ACH

60

ACH-120EQ-124H S62

3287083736

1-1/8", 2-1/8"

2-1/8"

137.1

12.1

0.95,1.58,1.58

3.62

20.43

EVP-50XXL-ACH

50

ACH-500EQ-70H Y55

3287084411

1-3/8", 2-5/8"

3" Victaulic

162.7

7.66

1.18, 2.05, 2.05

4.03

24.88

EVP-60XXL-ACH

60

ACH-500EQ-80H Y55

3287084412

1-3/8", 2-5/8"

3" Victaulic

181.2

8.69

1.18, 2.05, 2.05

4.03

24.88

EVP-75XXL-ACH

75

ACH-500EQ-100H Y55

3287084414

1-3/8", 2-5/8"

3" Victaulic

218.2

10.75

1.18, 2.05, 2.05

4.03

24.88

EVP-100XXL-ACH

100

ACH-500EQ-130H Y55

3287084415

1-3/8", 2-5/8"

3" Victaulic

273.7

13.83

1.18, 2.05, 2.05

4.03

24.88

Frame Size 24.3" H x 7.6" W (Includes studbolts)

Working Pressure 650 PSIG

Frame Size 33.5" H x 12.7" W (Includes lifting lugs and feet)

Nominal Tons - 12,000 BTU/H per Ton, 54 deg F EWT, 44 deg F LWT, 36 to 39 deg F SST
R410A, 6 deg F SuperHeat. 2.4GPM per Ton. Water press.drop less than 10 psig

For performance with other refrigerants and/or fluids other than water, please
contact Customer Service.

48

Working Pressure 650 PSIG

Menu
EVP-ACH2 - Copper-Brazed Heat Exchangers - R410A
High Efficiency Dual-Circuit Models

Evaporators

The EVP-ACH2 Dual Circuit Evaporators are copper-brazed and feature a built-in distributor.
Optimized for use with R410A.
For other refrigerants, please contact Customer Service or your Alfa Laval representative.
Two Frame Sizes
Model

Nominal
Tons*

Description

Part Number

Connections (ids)
Front Plate
Ref. In/Out3

Rear Plate
Water In/Out
T1 - T2

Frame Size 19" H x 10" W (includes studbolts)

Dimensions (in.)
Dry
Wt.
(lbs.)

"D"

"A"
Liq,Suct,Water

"B"
front

"C"
front/rear

Working Pressure 650 PSIG

EVP-12.5L-ACH2

12.5

ACH-230DQ-30H

3287084565

7/8", 1 1/8"

2" Victaulic

38

3.9

0.95, 1.18, 1.89

6.10

15.75, 14.53

EVP-20L-ACH2

20

ACH-230DQ-50H

3287084567

7/8", 1 3/8"

2" Victaulic

56

6.2

0.95, 1.18, 1.89

6.10

15.75, 14.53

EVP-30L-ACH2

30

ACH-230DQ-70H

3287084569

7/8", 1 3/8"

2" Victaulic

73

8.6

0.95, 1.18, 1.89

6.10

15.75, 14.53

EVP-40L-ACH2

40

ACH-230DQ-90H

3287084570

7/8", 1 5/8"

2-1/2" Victaulic

93

10.9

0.95, 1.18, 1.89

6.10

15.75, 14.53

EVP-50L-ACH2

50

ACH-230DQ-110H

3287084571

1 1/8", 1 5/8"

2-1/2" Victaulic

109

13.2

0.95, 1.18, 1.89

6.10

15.75, 14.53

EVP-60L-ACH2

60

ACH-230DQ-138H

3287084572

1 1/8", 2 1/8"

2-1/2" Victaulic

134

16.5

0.95, 1.57, 1.89

6.10

15.75, 14.53

EVP-70L-ACH2

70

ACH-230DQ-170H

3287084573

1 1/8", 2 1/8"

2-1/2" Victaulic

162

20.2

0.95, 1.57, 1.89

6.10

15.75, 14.53

EVP-80L-ACH2

80

ACH-230DQ-202H

3287084574

1 1/8", 2 1/8"

2-1/2" Victaulic

190

23.9

0.95, 1.57, 1.89

6.10

15.75, 14.53

Frame Size 29" H x 13" W (Includes lifting lugs and feet)

Working Pressure 650 PSIG

EVP-100XXL-ACH2

100

ACH-500DQ-110H

3287084579

1 3/8", 2 5/8"

3" Victaulic

238

11.8

1.18, 2.05, 2.05

8.07

24.87, 22.36

EVP-120XXL-ACH2

120

ACH-500DQ-138H

3287084581

1 3/8", 2 5/8"

3" Victaulic

290

14.7

1.18, 2.05, 2.05

8.07

24.87, 22.36

EVP-140XXL-ACH2

140

ACH-500DQ-170H

3287084583

1 3/8", 2 5/8"

3" Victaulic

349

17.9

1.18, 2.05, 2.05

8.07

24.87, 22.36

EVP-150XXL-ACH2

150

ACH-500DQ-190H

3287084584

1 3/8", 2 5/8"

3" Victaulic

386

20.0

1.18, 2.05, 2.05

8.07

24.87, 22.36

EVP-160XXL-ACH2

160

ACH-500DQ-206H

3287084585

1 3/8", 2 5/8"

3" Victaulic

416

21.6

1.18, 2.05, 2.05

8.07

24.87, 22.36

Nominal Tons - 12,000 BTU/H per Ton, 54 deg F EWT, 44 deg F LWT, 36 to 39 deg F SST R410A, 6 deg F SuperHeat. 2.4GPM per Ton. Water
press.drop less than 10 psig
2
For performance with other refrigerants and/or fluids other than water, please contact Customer Service.
3
Diagonal flow connectons.
1

49

Menu
Evaporators

ERS/ERD - One-Pass or Three-Pass Replacement Evaporators

Near drop-in replacement for single pass OEM designs


Design Features and Ratings
Models

Nom.
Cap.
Tons

Pressure
Drop
(psi)

Water
In & Out
(mpt)

Refrig.
Inlet
(ids)

Refrig.
Outlet
(ids)

Working
Pressure (psi)
Shell
Side

Weight
(lbs)

Tube
Side

1-Circuit
ERS00336

4.0

2.1

49.13

34.63

10.50

8.50

1 1/8* (ids)

5/8

1 1/8

225

225

190

ERS00424

3.9

3.5

37.13

22.12

10.88

8.88

1 3/8* (ids)

7/8

1 3/8

225

225

180

ERS00436

7.1

2.4

49.13

34.13

10.88

8.88

1 3/8* (ids)

7/8

1 3/8

225

225

200

ERS00448

9.7

4.6

61.13

46.13

10.88

8.88

1 3/8* (ids)

7/8

1 3/8

225

225

220

ERS00536

9.8

2.7

49.13

33.63

12.06

9.06

1 5/8* (ids)

7/8

2 1/8

225

225

280

ERS00548

14.0

2.7

60.94

45.62

12.06

9.06

1 5/8* (ids)

7/8

2 1/8

225

225

320

ERS00560

18.2

3.8

6 5/8

73.13

57.63

12.69

9.38

1 5/8* (ids)

7/8

2 1/8

200

300

320

ERS00636

16.0

5.1

6 5/8

45.63

32.00

11.38

8.06

1 1/8

2 1/8

200

300

330

ERS00648

21.4

2.7

6 5/8

57.63

44.00

11.38

8.06

1 1/8

2 1/8

200

300

360

ERS00660

27.7

4.8

8 5/8

69.63

56.00

11.38

8.06

1 1/8

2 1/8

200

300

530

ERS00736

27.5

4.3

8 5/8

47.13

32.13

14.06

10.13

1 1/8

2 5/8

200

300

460

ERS00748

34.6

3.7

8 5/8

59.13

44.13

14.06

10.13

1 1/8

2 5/8

200

300

500

ERS00760

40.9

3.8

8 5/8

71.13

56.13

14.06

10.13

1 1/8

2 5/8

200

300

550

ERS00848

44.9

5.9

10 3/4

59.88

41.50

15.19

10.69

1 1/8

2 5/8

200

300

670

ERS00860

53.9

4.2

10 3/4

71.88

53.50

15.19

10.69

1 1/8

2 5/8

200

300

720

ERS01048

54.2

3.6

10 3/4

60.50

41.50

16.56

11.50

1 3/8

3 1/8

200

300

680

ERS01060

68.4

4.5

10 3/4

72.50

53.50

16.56

11.50

1 3/8

3 1/8

200

300

740

ERS01160

84.6

4.9

12 3/4

73.00

53.50

17.69

12.06

1 3/8

3 1/8

200

300

960

ERS01260

93.3

6.0

12 3/4

73.63

53.50

18.94

12.75

1 5/8

3 1/8

200

300

970

ERS01360

111.4

5.9

14

74.25

53.50

20.06

13.31

1 5/8

3 1/8

200

300

1150

ERD00636

16.0

5.1

6 5/8

47.50

32.00

11.38

8.06

7/8

1 5/8

200

300

330

ERD00648

21.4

2.7

6 5/8

59.50

44.00

11.38

8.06

7/8

1 5/8

200

300

360

ERD00660

27.7

4.8

8 5/8

71.50

56.00

11.38

8.06

7/8

1 5/8

200

300

530

ERD00736

27.5

4.3

8 5/8

50.50

32.13

14.06

10.13

7/8

1 5/8

200

300

460

ERD00748

34.6

3.7

8 5/8

62.50

44.13

14.06

10.13

7/8

1 5/8

200

300

500

ERD00760

40.9

3.8

8 5/8

74.50

56.13

14.06

10.13

7/8

1 5/8

200

300

550

ERD00848

44.9

5.9

10 3/4

63.13

41.50

15.19

10.69

1 1/8

2 1/8

200

300

670

ERD00860

53.9

4.2

10 3/4

75.13

53.50

15.19

10.69

1 1/8

2 1/8

200

300

720

ERD01048

54.2

3.6

10 3/4

65.13

41.50

16.56

11.50

1 1/8

2 1/8

200

300

680

ERD01060

68.4

4.5

10 3/4

77.13

53.50

16.56

11.50

1 1/8

2 1/8

200

300

740

ERD01160

84.6

4.9

12 3/4

77.63

53.50

17.69

12.06

1 3/8

2 5/8

200

300

960

ERD01260

93.3

6.0

12 3/4

78.25

53.50

18.94

12.75

1 3/8

2 5/8

200

300

970

ERD01360

111.4

5.9

14

78.88

53.50

20.06

13.31

1 5/8

3 1/8

200

300

1150

2-Circuit

Insulation available upon request.

50

Menu
Evaporators

ERS/ERD - One-Pass or Three-Pass Replacement Evaporators


Water Flow Rates
There is one baffle configuration per ER model. As a result, the
water flow rate at the job site will need to be adjusted to obtain
the design water flow rate. At a range of 10F, the water flow
rate should be 2.4 gpm/ton.

Construction Materials
ER evaporator shells are constructed with ASME grade carbon
steel. Enhanced copper tubing is mechanically expanded for

ERS
1-Circuit

a superior seal into machined carbon steel tubesheets. Tubing


wall thickness is 0.018". Removable endplates, refrigerant and
water connections are constructed from carbon steel. All baffles
are made from corrosion-resistant materials.

Refrigerant Connections
The refrigerant side configuration for the ER evaporators
is 3-Pass with nozzles at opposite ends. As a result, the
refrigerant nozzles are on the same ends, but may not be in the
same locations as the other OEM Single Pass evaporators.

water inlet

water outlet

B
D

E
A

refrig. outlet

refrig. inlet

ERD
2-Circuit

water inlet

water outlet

B
D

E
A

Insulation available upon request.

refrig. inlet

refrig.
. outlet

51

Menu

C u s t o m D e s i g n Eva p ora t or Sp e c ific a t ion Da t a


Fax: 708-345-3513
or e-mail: stanref.customerservice@alfalaval.com

Customer Information
Company _______________________________________________________________________________________________________
Contact Name _____________________________________________________________

Date ______________________________

Phone __________________________________________________ Fax ___________________________________________________


E-Mail: _________________________________________________________________________________________________________

Evaporator Type
Brazed Plate
Shell-and-Tube

fouling factor _________(0.0001 ARI standard)


refrigerant ___________________________
suction temperature ______F of refrigerant
at evaporator

Evaporator Design
DX serviceable, no. circuits ______________
Flooded serviceable

Performance
inlet fluid temperature _________________F
outlet fluid temperature ________________F
net load _____________________________tons
pressure drop ________________________psi

Fluid Circulated
water _________________________%
ethylene glycol_________________%
propylene glycol________________%
calcium chloride (CaCl2) _________%
sodium chloride (NaCl)__________%
other_______ _________________%
specify properties at outlet temperature

specific gravity ____________________


thermal conductivity ________________
viscosity (centipose) ________________
specific heat ______________________
Con s t ru c tio n
size: width __________________ length_______________________ height _____________________
connections: refrigerant inlet _____________________ refrigerant outlet _______________________
specify ids, fpt, flange or flare: fluid inlet ____________________ fluid outlet ____________________
App licat ion
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________

Menu
Evaporators - Gasket Cross Reference

Models

Gasket Kit

Single
Circuit

Dual
Circuit

TX2

2865

Fig. A

NA

TX3

2865

Fig. A

NA

TX5

2872

Fig. A

NA

TX6

2872

Fig. A

NA

TX7.5

2872

Fig. A

NA

TX10

2872

Fig. A

Fig. C

TX12

2889

Fig. A

Fig. C

TX15

2889

Fig. A

Fig. C

TX20

2889

Fig. A

Fig. C

TX25

2889

Fig. A

Fig. C

TXC30

2218

Fig. B

Fig. D

TXC40

2227

Fig. B

Fig. D

TXC50

2227

Fig. B

Fig. D

TXC60

2227

Fig. B

Fig. D

TXC75

2227

Fig. B

Fig. D

TXC100

4892

Fig. A

Fig. C

TXC120

4892

Fig. A

Fig. C

TXC150

3549

NA

Fig. C

TXC175

5169

NA

Fig. D

TXC200

5169

NA

Fig.D

Figure A
Single Circuit
Dual Pass

Front

Figure B
Single Circuit
Four Pass

Front

Figure C
Dual Circuit
Dual Pass

Front

Rear

Rear

Figure D
Dual Circuit
Four Pass

Rear

Front

Rear

53

Menu
Subcoolers

SBC-AC - AlfaChill Copper-Brazed Plate Heat Exchangers - High Efficiency

Designed to cool liquid refrigerant adding more Btu's per pound - Ideal for low temperature applications.
The SBC-AC Subcoolers are copper-brazed and feature a built-in distributor.
Three Frame Sizes
Model

Nominal
Tons*

Description

Part Number

Connections (ids)
Ref. Liq/
Suction DX1
in/DX2 out

Frame Size 12.8" H x 3.7" W

Dimensions (in.)

Subcooled
Ref liq In/
Out

Dry
Wt.
(lbs.)

"D"

"A"
liq,Suc,
Water

"B"

"C"

Working Pressure 450 PSIG

SBC-2M-AC

1.5

ACH-30EQ-10H R52

3287084893

3/8, 7/8

7/8

4.2

0.9

0.95

1.54

10.6

SBC-3M-AC

ACH-30EQ-20H R52

3287084894

3/8, 7/8

7/8

6.2

1.5

0.95

1.54

10.6

SBC-4M-AC

ACH-30EQ-30H S09

3287084895

1/2, 7/8

7/8

8.2

2.1

0.95

1.54

10.6

SBC-6M-AC

ACH-30EQ-40H S09

3287084896

1/2, 7/8

7/8

10.2

2.7

0.95

1.54

10.6

SBC-7M-AC

ACH-30EQ-50H S21

3287084897

5/8, 1-1/8

1-1/8

12.2

3.3

0.95

1.54

10.6

SBC-9M-AC

ACH-30EQ-60H S21

3287084898

5/8, 1-1/8

1-1/8

14.2

3.9

0.95

1.54

10.6

SBC-10M-AC

10

AC-30EQ-70H S21

3287061352

5/8, 1-1/8

1-1/8

16.2

4.5

0.95

1.54

10.6

SBC-12M-AC

12

AC-30EQ-80H S21

3287061353

5/8, 1-1/8

1-1/8

18.2

5.1

0.95

1.54

10.6

SBC-15M-AC

15

AC-30EQ-100H S21

3287084898

5/8, 1-1/8

1-1/8

22.2

6.3

0.95

1.54

10.6

2.6

0.95

1.97

18.35

Frame Size 20.7" H x 4.4" W


SBC-4L-AC

SBC-5L-AC
SBC-6L-AC

Working Pressure 450 PSIG

AC-70X-14M S21

3287067204

5/8, 1-1/8

1-1/8

AC-70X-18M S21

3287067206

5/8, 1-1/8

1-1/8

9.7

0.95

1.97

18.35

ACH-70X-22M S21

3287083717

5/8, 1-1/8

1-1/8

11.3

3.3

0.95

1.97

18.35

SBC-8L-AC

ACH-70X-26M S21

3287083718

5/8, 1-1/8

1-1/8

12.9

3.7

0.95

1.97

18.35

SBC-10L-AC

10

ACH-70X-32M S21

3287083719

5/8, 1-1/8

1-1/8

15.3

4.2

0.95

1.97

18.35

SBC-12L-AC

13

ACH-70X-42M S24

3287083720

5/8, 1-3/8

1-1/8

19.3

5.1

0.95

1.97

18.35

SBC-15L-AC

16

ACH-70X-50M S24

3287083721

5/8, 1-3/8

1-1/8

22.5

5.9

0.95

1.97

18.35

SBC-20L-AC

19

ACH-70X-62M S25

3287083723

5/8, 1-3/8

1-1/8

25.7

6.6

0.95

1.97

18.35

SBC-21L-AC

21

ACH-70X-78M R49

3287083725

5/8, 1-3/8

1-3/8

27.3

0.95

1.97

18.35

SBC-30L-AC

31

ACH-70X-100M R49

3287083727

5/8, 1-1/8

1-3/8

29.7

7.5

0.95

1.97

18.35

Frame Size 33.5" H x 12.7" W


SBC-15XL-AC

14

ACH-120EQ-30H S46

3287083729

SBC-25XL-AC

23

ACH-120EQ-46H S62

SBC-30XL-AC

30

ACH-120EQ-60H S62

SBC-40XL-AC

38

SBC-45XL-AC

8.2

Working Pressure 435 PSIG


7/8, 2-1/8

2-1/8

42.7

3.2

1.58*

3.62

20.43

3287083731

7/8, 2-1/8

2-1/8

58.2

4.7

1.58*

3.62

20.43

3287083732

1-1/8, 2-1/8

2-1/8

77.8

6.0

1.58*

3.62

20.43

ACH-120EQ-76H S62

3287083733

1-1/8, 2-1/8

2-1/8

87.4

7.5

1.58*

3.62

20.43

45

ACH-120EQ-90H S62

3287083734

1-1/8, 2-1/8

2-1/8

101

8.8

1.58*

3.62

20.43

SBC-50XL-AC

53

ACH-120EQ-106H S62

3287083735

1-1/8, 2-1/8

2-1/8

116.6

10.2

1.58*

3.62

20.43

SBC-60XL-AC

62

ACH-120EQ-124H S62

3287083736

1-1/8, 2-1/8

2-1/8

134.1

11.9

1.58*

3.62

20.43

SBC-85XL-AC

85

ACH-120EQ-180H S76

3287083738

1-1/8, 2-1/8

2-1/8

188.5

17.1

1.58*

3.62

20.43

Nominal Tons - Liquid Ref to be subcooled from 110F to 50F, R-22, 40F SST, 7F Superheat

SB2
DX2
(Ref gas (subcooled
out)
liq in)

DX1
SB1
(Ref liq (subin)
cooled
liq out)

54

Menu
Chiller Builder Kit with shell-and-tube - Lowside

Chiller Builder Kits from Standard Refrigeration


Our ChillerBuilder Kits allow you to assemble a modular chiller solution in under an hour. Available from 2
to 75 tons, these kits provide all you need to build the low-side of a chiller system. You get the reliable TX
evaporator, brand-name controls and components and custom-cut piping and framework.
Select a condensing unit and you've got a modular chiller perfect for spacetight commercial AC applications
or boosting existing system capabilities.

Flow-switch
Contractor
favorite TX
shell-and-tube
serviceable
chiller barrel

Preset temperature controls

Expansion
valves

Solenoid
valve

Sightglass
Temperature
probe

Control Box
Low pressure switch

Custom-cut piping

Custom cut brackets and framework


*Chiller Builder Kits can be custom ordered for use with R410A - Consult factory.

55

Menu
Chiller Builder Kit - Lowside
Lowside ChillerBuilder Kits with digital controls
Kits now available up to 75 Tons

R22 performance, easy field assembly


Simply match the kit with the a corresponding high side condensing unit to complete the cycle
Shell-and-tube kits for R410A are available, contact Customer Service
Design Features and Ratings
ChillerBuilder Kit Dimensions
Kit

Nom'l
Tons*

Circuits

Chiller
Barrel
(included)

TX-Kit
(Control pack
and framework
included)

Water
Conn.
(fpt)

Liquid
Conn.
(ids)

Suction
Conn.
(ids)

CBKIT2 - 1

TX2-1

TXKIT1

21

18 14

19 34

14

14

30 14

58

78

CBKIT3 - 1

TX 3-1

TXKIT2

26

18 14

19 34

18

14

30 14

58

78

CBKIT5 - 1

TX 5-1

TXKIT2

26

18 14

31 38

18

16

42 14

1 14

58

1 18

1-Circuit

CBKIT6 - 1

TX 6-1

TXKIT3

27

18 14

31 18

18

19

42 14

1 12

58

1 18

CBKIT7.5 - 1

712

TX 712-1

TXKIT3

27

18 14

31 18

18

19

42 14

1 12

58

1 58

CBKIT10 - 1

10

TX10-1

TXKIT3

27

18 14

30 38

18

19

42 14

58

1 581

CBKIT12 - 1

12

TX12-1

TXKIT3

27

19 38

30 18

18

21

43 14

58

1 58

CBKIT15 - 1**

15

TX15-1

TXKIT4

32

20 38

29 58

18

21

44 14

2 12

78

2 18

CBKIT20 - 1**

20

TX20-1

TXKIT4

32

20 38

29

18

21

44 14

78

2 18

CBKIT25 - 1**

25

TX25-1

TXKIT4

32

20 38

29

18

21

44 14

78

2 58

CBKIT30 - 1***

30

TXC30-1

TXCKIT5

63

22

16

90

1 18

2 58

CBKIT40 - 1***

40

TXC40-1

TXCKIT6

63

24

17

90

1 38

2 58

2-Circuit
CBKIT10-2

10

TX10-2

DTXKIT 10-12

29

18 1/4

30 3/8

20

17

45 1/4

5/8

1 5/8

CBKIT12-2

12

TX12-2

DTXKIT 10-12

29

19 3/8

30 1/8

20

19

46 1/4

5/8

1 5/8

CBKIT15-2

15

TX15-2

DTXKIT 15-20

29

19 38

29 5/8

20

21

46 14

2 1/2

58

2 18

CBKIT20-2

20

TX20-2

DTXKIT 15-20

29

19 3/8

29

20

21

46 1/4

5/8

2 1/8

CBKIT25-2

25

TX25-2

DTXKIT 15-20

29

19 38

29

20

21

46 14

58

2 58

CBKIT30-2***

30

TXC30-2

DTXCKIT 30

63

22

19

90

78

1 58

CBKIT40-2***

40

TXC40-2

DTXCKIT 40

63

24

20

90

1 18

1 58

CBKIT50-2***

50

TXC50-2

DTXCKIT 50

63

24

20

90

1 18

2 18

CBKIT60-2***

60

TXC60-2

DTXCKIT 60

73

24

22

104

1 18

2 18

CBKIT75-2***

75

TXC75-2

DTXCKIT 75

73

24

22

104

1 38

2 58

CBKIT15-3

15

TX15-3

TXKIT15-3

30 34

23 14

80

2 12

38

1 18

CBKIT20-4

20

TX20-4

TXKIT20-4

30 34

23 14

80

38

1 18

Multi Circuit

120 volts required to operate Chiller Builder Kits.


* Tonnage capacities based on TXV capacities at 35 F suction, 115 F condensing temperature, 54 F inlet water, and 44 F outlet water using R-22
** Pumpdown cycle included with CBKIT15-1, CBKIT20-1, and CBKIT25-1
*** Kits 30 through 75 tons include unloading feature. Kits with no unloading feature are also available.
All Chiller Builder Kits include chiller barrel. Chiller Builder kits without chiller barrel are available. Call the factory for more information.
All Chiller Builder Kits can be special ordered for use with refrigerant R410a.

56

Uses compact TX/TXC chiller barrel


Brand name components
One, two, three and four circuit options
NEW three and four circuit models available, ideal for
achieving up to 20 tons with single-phase compressors
Available in ranges from two to 75 tons
Entire kit can be assembled in less than one hour
Chiller barrel included
NEW-includes Digital Controls

Included components
Framework
Temperature controls
Low pressure switch
Expansion valve
Solenoids
Control power supplies
Freezestat
Flow switch
Sight glasses

Menu
Chiller Builder Kit - Lowside Chiller Builder Kits

control box

water fittings

temperature probe
COMP 2
CONTROL
SWITCH
ON

evaporation
(included with kit)

OFF

W fluid outlet

CIRCUIT
BREAKER

solenoid valve
sight glass

ON

freeze protection low


pressure switch

W fluid outlet

flow switches

COMP 1
CONTROL
SWITCH

control switches

Q refrig. outlet

OFF

1-Circuit

H
expansion valve

D
P refig. outlet
A

2-Circuit
flow switches

control box
COMP 1
CONTROL
SWITCH

CIRCUIT
BREAKER

ON

COMP 2
CONTROL
SWITCH
OFF

ON

freeze protection low


pressure switch

W fluid outlet

water fittings

temperature probe
solenoid valve
sight glass

OFF

control switches

Q refrig. outlet
H

W fluid outlet
D

evaporation
(included with kit)

expansion valve

P refig. outlet
L

3 & 4 Circuit

W fluid out

W fluid in
NOTE: Connection
locations vary
between 3&4
circuit models

flow switch
temperature
probe

evaporator (included)

control switch

CBKIT15-3
freeze protection low
pressure switch (3)

solenoid valve (3)


expansion valve (3)
sight glass

control box

Q Refrig. out

H
H

P Refrig. inlet

CBKIT20-4

freeze protection low


pressure switch (4)

sight glass

solenoid valve (4)


expansion valve (4)

control box
CONTROL BOX

Q Refrig. out

P Refrig. inlet

57

Menu
BHE Chiller Builder Kit - Complete Chiller Lowside

Chiller Builder Kit

Chiller Builder Kits


For Brazed Plate Evaporators
Build a complete water chiller quickly and economically.

Brand name components

Connects to your condensing unit

Available in ranges from 2 to 80 tons

Immediate availability

Entire kit can be assembled in less than one hour

Combine a Chiller Builder Kit with an Alfa Laval brazed


plate evaporator for a complete low side chiller ready to be
connected to your condensing unit. The components and
controls are properly matched to the evaporator, and can be
used in either pump-down and non-pump-down systems.

Includes digital controls

The evaporator and components are quickly assembled on the


compact structural steel frame. The completed assembly can
be conveniently located near the air handler or process load.

Included Components
Structural Steel Framework
Electronic chiller controller with fault indicating lights
Temperature control
Electronic low pressure freeze protection switch

The Chiller Builder controls connect to the condensing unit


thermostat terminals for simple and fool-proof installation and
operation.

Expansion valve(s)

Uses compact and efficient brazed plate evaporators

Freezestat

Available in single and dual refrigerant circuit models

Flow switch

Available for R410A, R404A, R507, R22

Water strainer

Solenoid(s)
Sight glass(es)

Single Circuit
Chiller Builder

Combine a Chiller Builder Kit, BHE


evaporator, and your condensing unit to
create a complete water chiller ready to
be piped to your cooling load.

Assembled Chiller Builder


58

Dual Circuit
Chiller Builder

Menu
BHE Chiller Builder Kit - Complete Chiller Lowside

Chiller Builder Kit

Lowside chiller kits with digital controls.


Kits available up to 80 tons for R410A, R22, R404A, R507 and other refrigerants.
Easy field assembly.
Order the kit model and the corresponding BHE evaporator model for the refrigerant being used.

Nom'l
Tons

Kit Model
(Control pack
and framework
only,
Evaporator
sold
separately)

BHE Evaporator Models


Refrigerant (Not included in the kit)

R410A

Assembled Kit Dimensions

R404A / R507

R22

L
Length

W
Width

H
Height

W**
Water Conn.
(ids)

P**
Liquid
Conn.
(ids)

Q**
Suction
Conn.
(ids)

Kit
Wt.
Lbs.
***

Single Refrigerant Circuit Models


2

BHEKIT-2-1-*

ACH-30EQ-20H

ACH-30EQ-20H

ACH-30EQ-20H

32"

24"

19"

7/8"

3/8"

7/8"

40

BHEKIT-3-1-*

ACH-30EQ-30H

ACH-30EQ-30H

ACH-30EQ-30H

32"

24"

19"

7/8"

3/8"

7/8"

45

BHEKIT-5-1-*

ACH-30EQ-40H

ACH-30EQ-40H

ACH-30EQ-50H

32"

24"

19"

7/8"

3/8"

7/8"

45

7.5

BHEKIT-7.5-1-*

ACH-70X-32M

ACH-70X-32M

ACH-70X-32M

34"

25"

28"

1-1/8"

5/8"

1-1/8"

65

10

BHEKIT-10-1-*

ACH-70X-42M

ACH-70X-42M

ACH-70X-50M

34"

25"

28"

1-1/8"

5/8"

1-1/8"

65

15

BHEKIT-15-1-*

ACH-70X-62M

ACH-70X-62M

ACH-70X-78M

34"

25"

28"

1-1/8"

5/8"

2-1/8"

70

20

BHEKIT-20-1-*

ACH-70X-78M

ACH-70X-100M

ACH-70X-100M

34"

25"

28"

1-3/8"

7/8"

2-1/8"

75

25

BHEKIT-25-1-*

ACH-120EQ-46H

ACH-120EQ-76H

ACH-120EQ-76H

38"

31"

34"

2-1/8"

7/8"

2-1/8"

115

30

BHEKIT-30-1-*

ACH-120EQ-60H

ACH-120EQ-90H

ACH-120EQ-90H

38"

31"

34"

2-1/8"

1-1/8"

2-1/8"

115

40

BHEKIT-40-1-*

ACH-120EQ-76H

ACH-120EQ-106H

ACH-120EQ-124H

38"

31"

34"

2-1/8"

1-1/8"

2-1/8"

125

Dual Refrigerant Circuit Models


10

BHEKIT10-2-*

ACH-230DQ-30H

ACH-230DQ-30H

ACH-230DQ-50H

40"

22"

30"

2" Victaulic

3/8"

1-1/8"

90

15

BHEKIT15-2-*

ACH-230DQ-30H

ACH-230DQ-50H

ACH-230DQ-50H

40"

22"

30"

2" Victaulic

5/8"

1-3/8"

90

20

BHEKIT20-2-*

ACH-230DQ-50H

ACH-230DQ-70H

ACH-230DQ-70H

40"

22"

30"

2" Victaulic

5/8"

1-3/8"

90

25

BHEKIT25-2-*

ACH-230DQ-50H

ACH-230DQ-70H

ACH-230DQ-70H

44"

22"

32"

2" Victaulic

5/8"

1-3/8"

95

30

BHEKIT30-2-*

ACH-230DQ-70H

ACH-230DQ-90H

ACH-230DQ-90H

48"

24"

32"

2" Victaulic

7/8"

1-3/8"

95

40

BHEKIT40-2-*

ACH-230DQ-70H

ACH-230DQ-110H

ACH-230DQ-110H

50"

24"

32"

2" Victaulic

7/8"

1-5/8"

125

50

BHEKIT50-2-*

ACH-230DQ-90H

ACH-230DQ-138H

ACH-230DQ-138H

53"

24"

34"

2" Victaulic

7/8"

1-5/8"

125

60

BHEKIT60-2-*

ACH-230DQ-110H

ACH-230DQ-138H

ACH-230DQ-170H

53"

24"

34"

2" Victaulic

1-1/8"

2-1/8"

140

80

BHEKIT80-2-*

ACH-230DQ-170H

ACH-230DQ-202H

ACH-230DQ-202H

60"

26"

34"

2" Victaulic

1-1/8"

2-1/8"

140

* Refrigerant, e.g., The model number of a nominal 10 ton single circuit kit for R410A will be BHEKIT-10-1-410.
** Based on R410A. Contact factory for other refrigerant and water line sizes.
*** Does not include the weight of evaporator.

Features

Includes Components

Uses compact and efficient Brazed Plate Evaporators

Framework

Available for R410A, R404A, R507, R22 and others

Electronic chiller controller with fault indicating lights

Brand name components

Temperature control

One and two refrigerant circuit models available

Low pressure freeze protection switch

Available in ranges from two to 80 tons

Expansion valve(s)

Entire kit can be assembled in less than one hour

` Solenoid(s)

Includes Digital Controls

Sight glass(es)
Freezestat
Flow switch
Water strainer

59

Menu
Liquid Receivers

Design Features and Ratings


Conformance
Each Standard stock receiver conforms to UL, CSA or ASME
requirements for 600 and 675 psi maximum working pressure.
Models with an internal diameter under six inches are UL listed;
all larger models are made according to ASME code and
tagged appropriately.
Pumpdown and Refrigerant Charge
All pumpdowns are calculated at 80% capacity of liquid.
Approximately 10% of pumpdown capacity is required to
operate receiver properly.
Custom and Ammonia Construction
Custom receivers for halocarbons and ammonia can be built
based on application and construction criteria. Receivers may
be ordered with or without extra features such as mounting

brackets, fusible plugs, special fittings, liquid level indicators


and alarm switches, to assure reliable service on virtually any
application involving halocarbon type refrigerants.

Selection
Pumpdown Calculation Procedure
Refer to table for calculating pumpdown capacity of any
Standard receiver design with elliptical ends. Pumpdown
figures shown have been compensated to directly give capacity
on 80% of the receiver volume filled with liquid at 90F.
To figure pumpdown capacity, locate the receiver OD in the first
column and read across to find the values for length correction
and pounds of pumpdown for refrigerant used. Substitute
those values in this formula:

Pumpdown =
(overall length - length correction) x (pumpdown per inch)
To calculate overall length required for the given OD and specified pumpdown capacity, follow the same procedure given above,
using thisformula:

Overall length =
(pumpdown required pumpdown per inch) + (length correction)
Receiver OD
(inches)

Length
Correction
(inches)

Pumpdown per inch


R-22

R-134A

R404A

R410A

End to
Weld
(inches)

0.9

0.38

0.38

0.33

0.39

1 7/8

(LBS)

1.1

0.60

0.61

0.52

0.62

1 7/8

1.2

0.88

0.89

0.76

0.91

2 3/8

6 5/8

1.4

1.06

1.08

0.92

1.10

2 7/8

8 5/8

1.8

1.82

1.84

1.58

1.88

3 1/8

10 3/4

2.3

2.80

2.84

2.44

2.89

4 1/2

12 3/4

2.6

3.96

4.01

3.45

4.09

5 1/2

14

2.9

4.77

4.83

4.15

4.93

5 7/8

16

3.2

6.31

6.38

5.49

6.52

6 3/8

18

3.7

7.94

8.03

6.90

8.20

6 3/4

20

4.0

9.89

10.01

8.60

10.22

7 1/4

24

4.9

14.11

14.28

12.28

14.58

8 1/2

30

5.2

22.44

22.71

19.52

23.19

10

36

5.6

32.68

33.07

28.43

33.77

11 1/2

UR-410
HR-410
RBV-410

60

UV-410

Menu
HR-410 - Horizontal Receivers

Receivers

High Working Pressure Rating for Refrigerant R410A


Also Suitable for R22, R134A, R404A, R507 applications
Design Features and Ratings
Models

Pumpdown* (lbs)

Dimensions (inches)

Connections (in.)

Shipping
Weight
(lbs)

R-410A

R-22

R-134A

P
(ids)

Q
(ids)

S
(fpt)

2855-410

14

16

16 1/5

5 9/16

28

4 1/2

23 1/2

5/8

5/8

3/8

20

3065-410

25

28

28

6 5/8

30

25

5/8

5/8

3/8

25

3665-410

31

35

35

6 5/8

36

31

5/8

5/8

3/8

32

3865-410

34

39

40

6 5/8

38

33

7/8

5/8

1/2

44

2885-410

42

48

49

8 5/8

28

5 5/8

22 3/8

1 1/8

7/8

1/2

47

3685-410

54

68

63

8 5/8

36

5 5/8

30 3/8

1 1/8

7/8

1/2

68

4285-410

64

73

74

8 5/8

42

5 5/8

36 3/8

1 1/8

7/8

1/2

74

4885-410

74

84

85

8 5/8

48

5 5/8

42 3/8

1 1/8

1 1/8

1/2

80

6085-410

93

106

107

8 5/8

60

5 5/8

54 3/8

1 1/8

1 1/8

1/2

112

36105-410

83

94

96

10 3/4

36

29

1 3/8

1 3/8

1/2

120

48105-410

112

128

130

10 3/4

48

41

1 3/8

1 3/8

1/2

144

60105-410

142

162

164

10 3/4

60

53

1 3/8

1 3/8

1/2

173

72105-410

171

195

197

10 3/4

72

65

1 3/8

1 3/8

1/2

204

96105-410

230

262

265

10 3/4

96

89

1 5/8

1 3/8

1/2

296

48122-410

158

180

182

12 3/4

48

8 1/2

39 1/2

1 5/8

1 3/8

1/2

189

60122-410

200

227

230

12 3/4

60

8 1/2

51 1/2

1 5/8

1 3/8

1/2

227

72122-410

242

275

278

12 3/4

72

8 1/2

63 1/2

2 1/8

1 3/8

1/2

270

96122-410

325

370

374

12 3/4

96

8 1/2

87 1/2

2 1/8

1 3/8

1/2

374

72145-410

290

330

334

14

72

9 1/2

62 1/2

2 1/8

1 5/8

1/2

329

96145-410

390

444

450

14

96

9 1/2

86 1/2

2 5/8

2 1/8

1/2

442

60166-410

315

358

362

16

60

51

2 5/8

2 1/8

1/2

318

72166-410

381

434

439

16

72

63

2 5/8

2 1/8

1/2

395

96166-410

515

586

592

16

96

87

2 5/8

2 1/8

1/2

505

72188-410

476

542

549

18

72

10

62

3 1/8

2 1/8

1/2

530

* All pumpdowns are calculated at 80% of receiver volume and liquid refrigerant at 90F
Use the following multipliers for refrigerants other than shown above: R-12= R-22 capacity X 1.10
R-502= R-22 capacity X 1.01
R-404A= R-22 capacity X 0.89
R-507= R-22 capacity X 0.88

Working Pressure: 675 psi @ 150F

Tag location may vary per model.

61

Menu
RBV-410 - Horizontal Receivers with Brackets and Valves

Receivers

High Working Pressure Rating for Refrigerant R410A


Also Suitable for R22, R134A, R404A, R507 applications
Design Features and Ratings
Model

Pumpdown* (lbs)

Dimensions (inches)

R-410

R-22

R-134A

RBV2855-410

14

16

16

5 9/16

28

4 1/2

RBV3865-410

34

39

40

6 5/8

38

RBV3685-410

54

62

63

8 5/8

36

5 5/8

RBV4285-410

64

73

74

8 5/8

42

5 5/8

Connections

Valve Part
Number

Ship
Wt
(lbs)

1/2

V04ST

25

1/2

V05ST

47

7/8

1/2

V07ST

72

1 1/8

1/2

V09ST

78

P&Q
(ids)

S (fpt)

23 1/2

14

5 1/2

1/2

33

9 1/2

19

5 1/2

5/8

30 3/8

18

36 3/8

10 1/2

21

RBV36105-410

83

94

96

10 3/4

36

29

18

10

1 1/8

1/2

V09ST

122

RBV48105-410

112

128

130

10 3/4

48

41

12

24

10

1 1/8

1/2

V09ST

151

RBV60105-410

142

162

164

10 3/4

60

53

15

30

10

1 1/8

1/2

V09ST

177

RBV48122-410

158

180

182

12 3/4

48

8 1/2

39 1/2

12

24

11 5/8

1 3/8

1/2

V11ST

193

RBV60122-410

200

227

230

12 3/4

60

8 1/2

51 1/2

15

30

11 5/8

1 3/8

1/2

V11ST

233

RBV72145-410

290

330

334

14

72

9 1/2

62 1/2

18

36

13 1/4

1 5/8

1/2

valve-85A

353

RBV96145-410

390

444

450

14

96

9 1/2

86 1/2

24

48

13 1/4

1 5/8

1/2

valve-85A

466

RBV96166-410

515

586

592

16

96

87

24

48

15 3/4

2 1/8

1/2

valve-621A

530

* All pumpdowns are calculated at 80% of receiver volume and liquid refrigerant at 90F
Use the following multipliers for refrigerants other than shown above:
R-12= R-22 capacity X 1.10
R-502= R-22 capacity X 1.01
R-404A= R-22 capacity X 0.89
R-507= R-22 capacity X 0.88
Working Pressure: 675 psi @ 150F

Tag location may vary per model.

62

Menu
UR-410 - Upright Receivers

Receivers

High Working Pressure Rating for Refrigerant R410A


Also Suitable for R22, R134A, R404A, R507 applications
Design Features and Ratings
Model

Pumpdown* (lbs)

Dimensions (inches)

Connections

Mounting

Ship
Wt
(lbs)

R-410A

R-22

R-134A

P (ids)

Q (ids)

S (fpt)

C
B.C.

D
Holes

UR20-410

16

18

19

8 5/8

12

5/8

5/8

3/8

10 5/8

0.38

30

UR28-410

23

26

26

8 5/8

16

11

5/8

5/8

3/8

12 3/4

0.38

36

UR48-410

39

44

45

10 3/4

18

6 5/8

11 3/8

1 1/8

7/8

1/2

12 3/4

0.38

62

UR66-410

54

61

62

12 3/4

18

7 1/2

10 1/2

1 1/8

1 1/8

1/2

14 3/4

0.38

83

UR72-410

59

67

68

12 3/4

20

7 1/2

12 1/2

1 1/8

1 1/8

1/2

14 3/4

0.38

92

UR84-410

75

85

85

12 3/4

24

7 1/2

16 1/2

1 1/8

1 1/8

1/2

14 3/4

0.38

102

UR108-410

89

101

102

14

24

8 1/2

15 1/2

1 3/8

1 3/8

1/2

16

0.56

115

UR137-410

115

131

133

16

24

16

1 3/8

1 3/8

1/2

18

0.56

146

UR151-410

137

156

158

12 3/4

42

7 7/8

34 1/8

1 3/8

1 3/8

1/2

14 3/4

0.38

177

UR174-410

142

161

163

18

24

15

1 5/8

1 5/8

1/2

20

0.56

182

UR201-410

181

206

208

14

46

37

1 5/8

1 5/8

1/2

16

0.56

218

UR276-410

249

283

286

16

48

39

2 1/8

1 5/8

1/2

18

0.56

255

2 1/8

1/2

18

0.56

312

2 1/8

1/2

20

0.56

452

UR351-410

315

358

362

16

60

9 1/2

50 1/2

2 5/8

UR451-410

407

463

468

18

62

9 1/2

52 1/2

2 5/8

* All pumpdowns are calculated at 80% of receiver volume and liquid refrigerant at 90F
Use the following multipliers for refrigerants other than shown above:
R-12= R-22 capacity X 1.10
R-502= R-22 capacity X 1.01
R-404A= R-22 capacity X 0.89
R-507= R-22 capacity X 0.88

Working Pressure: 675 psi @ 150F

63

Menu
UV-410 - Upright Receivers

Receivers

High Working Pressure Rating for Refrigerant R410A


Also Suitable for R22, R134A, R404A, R507 applications
Design Features and Ratings
Model

UV30-410

Pumpdown* (lbs)

Dimensions (inches)

Connections

R-22

R-134A

P&Q
(ids)

S (fpt)

C
B.C.

D
Holes

25

29

30

8 5/8

18

5 3/8

12 6/8

1/2

3/8

10 5/8

0.38

Valve Part
Number

Ship
Wt
(lbs)

H04ST

42

UV40-410

35

40

41

8 5/8

24

5 3/8

18 6/8

5/8

3/8

10 5/8

0.38

H05ST

49

UV50-410

48

55

56

8 5/8

32

5 4/8

26 5/8

7/8

3/8

10 5/8

0.38

H07ST

62

UV70-410

63

72

73

10 3/4

28

6 5/8

21 3/8

1 1/8

1/2

12 3/4

0.38

H09ST

94

UV100-410

88

100

101

10 3/4

38

6 5/8

31 3/8

1 1/8

1/2

12 3/4

0.38

H09ST

125

UV125-410

116

132

134

12 3/4

36

7 7/8

28 1/8

1 1/8

1/2

14 3/4

0.38

H09ST

166

UV150-410

137

156

158

12 3/4

42

7 7/8

34 1/8

1 1/8

1/2

14 3/4

0.38

H09ST

182

UV200-410

181

206

208

14

46

37

1 3/8

1/2

16

0.56

H11ST

224

UV275-410

249

283

286

16

48

8 1/2

39 1/2

1 5/8

1/2

18

0.56

valve-85A

260

UV350-410

315

358

362

16

60

8 1/2

51 1/2

1 5/8

1/2

18

0.56

valve-85A

317

UV450-410

407

463

468

18

62

9 1/2

52 1/2

1 5/8

1/2

20

0.56

valve-85A

458

* All pumpdowns are calculated at 80% of receiver volume and liquid refrigerant at 90F
Use the following multipliers for refrigerants other than shown above:
R-12= R-22 capacity X 1.10
R-502= R-22 capacity X 1.01
R-404A= R-22 capacity X 0.89
R-507= R-22 capacity X 0.88

64

Mounting

R-410A

Working Pressure: 675 psi @ 150F

Menu
Receivers

Compact Vertical L - Receivers with Valve and Fusible Plug

Design Features and Ratings


Model

Pumpdown*
(lbs)
R-22

R-134A

L-408C

2.9

L-413C

5.0

Dimensions (inches)
B

2.95

na

5.10

3 12

Connections

W
Weld
Screw

Ship Wt
(lbs)

P (ids)

Q (flare)

S (fpt)

2 1116

38

38

18

38-16 x 1

13 12

2 12

38

38

38

38-16 x 1

10

L-516C

9.3

9.45

3 12

16

2 12

12

1/2

38

38-16 x 1

14

L-618C

15.3

15.56

3 12

18

2 12

12

1/2

38

12-13 x 1

19

L-623C

19.7

20.03

3 12

23

2 12

12

1/2

38

12-13 x 1

24

L-630C

25.3

25.7

3 58

30

2 12

5/8

5/8

38

12-13 x 1

29

* All pumpdowns are calculated at 80% of receiver volume and liquid refrigerant at 90F
Use the following multipliers for refrigerants other than shown above:
R-12= R-22 capacity X 1.10
R-502= R-22 capacity X 1.01
R-404A= R-22 capacity X 0.89
R-507= R-22 capacity X 0.88

R410A rated L series


receivers are available,
consult with factory.

Working Pressure: 500 psi

S safety
w/430 fusible plug

D
Refrig. inlet Q (ids)
P refrig. outlet with
brazed on flare valve

B
W weld screw

P refrig. outlet with


brazed on flare valve

S safety
w/430 fusible plug
Refrig. inlet Q
(flare)

W weld screw
D

65

Menu
Rotalock Valve

Product Accessories

Design Features and Ratings


A
gage port

B
C

body

Connections

Left
Gage
Port

Right
Gage
Port

Body Size

Body

Coupling

Top
Gage
Port

3/8 flare

3/416

H03FT

H03FL

H03FR

1/2 flare

114

H04FT

H04FL

H04FR

5/8 flare

114

H05FT

H05FL

H05FR

1/2 ids

114

H04ST

H04SL

H04SR

5/8 ids

114

H05ST

H05SL

body connection
coupling connection
Dimensions (inches)
A

3/4 hex

3 2332

1 1732

1 316

2532

7/8 sq

4 1/8

1 2332

1 516

3/4

1 116

7/8 sq

4 3/8

1 3132

1 916

3/4

1 116

7/8 sq

4 132

1 5/8

1 732

3/4

1 116

H05SR

7/8 sq

4 932

1 7/8

1 1532

3/4

1 116

7/8 ids

1 1/412

H07ST

H07SL

H07SR

1 1/8 sq

5 3/8

2 1132

1 1116

3132

1 316

1 1/8 ids

1 1/412

H09ST

H09SL

H09SR

1 1/8 sq

5 5/8

2 1932

1 1532

3132

1 316

1 3/8 ids

1 3/412

H11ST

H11SL

n/a

1 3/8 sq

7 316

3 516

2 1532

1 316

1 516

Use stem end of valve & coupling connection as reference when determining gage port position

body

gage port

body connection

E
A
B
C
D

coupling connection

Coupling

Top
Gage Port

Left
Gage Port

Right
Gage Port

Body Size

Body

Connections
3/8 flare

3/416

V03FT

V03FL

V03FR

3/4 hex

Dimensions (inches)
A

3 116

1 532

1316

1 1/8

1/2 flare

114

V04FT

V04FL

V04FR

7/8 sq

3 516

1 932

7/8

1 932

1 116

5/8 flare

114

V05FT

V05FL

V05FR

7/8 sq

3 516

1 932

7/8

1 1732

1 116

1/2 ids

114

V04ST

V04SL

V04SR

7/8 sq

3 1116

1 932

7/8

1 132

1 116

5/8 ids

114

V05ST

V05SL

V05SR

7/8 sq

3 1116

1 932

7/8

1 132

1 116
1 316

7/8 ids

1 1/412

V07ST

V07SL

V07SR

1 1/8 sq

4 2532

1 3/4

1 332

1 916

1 1/8 ids

1 1/412

V09ST

V09SL

V09SR

1 1/8 sq

4 2532

1 3/4

1 332

1 1316

1 316

1 3/8 ids

1 3/412

V11ST

V11SL

n/a

1 3/8 sq

6 316

2 516

1 1532

2 316

1 516

Use stem end of valve & coupling connection as reference when determining gage port position
66

Menu
(4) Bolt Flanged Valve/Indicator
Components

Product Accessories

Horizontal Refrigerant Valves

part number valve-85A


used on RBV-72145 & RBV-96145 UV 275, UV350, UV 450
part number valve-621A used on RBV-96166
Both valves utilize the four (4) bolt mating flanges installed on these
receivers
All valves suitable for R410A applications

Part number

B dia. to 4-bolt flange

Dimensions (inches)
A

valve-85A

1.5/8

2.1/8

1.1316

3.1516

9.1/2

valve-621A

2.1/8

2.1732

2.3/8

5.116

12

LLI / LLH components


Part number
GASKE 995

Neoprene flat
gasket. Fits current
indicator and alarm
adaptor on units
manufactured after
1972

INDIC 21

Replacement dial
for LLI indicators

INDIC 49

Replacement
switch for LLH
alarms

67

Menu
Float Type Indicators

Part number
Low Pressure
INDIC283A 6 5/8"
INDIC111A 8 5/8"
INDIC76A 10 3/4"
INDIC85A 12 3/4"
INDIC94A 14"
INDIC102A 16"
INDIC483A 18"
INDIC490A 20"
INDIC497A 24"
High Pressure
INDIC438A 8 5/8"
INDIC395A 10 3/4"
INDIC407A 12 3/4"
INDIC421A 16"

Liquid Level

Magnetic liquid level indicators are an inexpensive, effective means


of gauging the refrigerant level in a horizontal receiver. The dial reads
percent of pumpdown capacity of the receiver: when the pointer
indicates 100%, the receiver is 80% full of liquid.
Pounds of refrigerant can be determined by taking the indicated
percentage of the specified pumpdown capacity of the receiver.
Normal location is on the side of the receiver, centered between the liquid
inlet and outlet connections. Other locations may be provided if specified.
Note that at least six inches are required between centers of adjacent
liquid level indicator flanges, and also between a unit and the liquid outlet
pickup tube.
These can be mounted in the center of either end, provided the
respective inlet or outlet fitting is moved to 1 1/2 tank diameters from that
end.
Float and assembly dial are included.
The diameter of the vessel is required for sizing the indicator. The "A" suffix
indicates that the corresponding gasket is included.

Low Pressure
INDIC58A
High Pressure
INDIC445A

Liquid Level Alarm


A liquid-level indicator is a single pole, single throw switch on which contacts
close upon the decrease of the liquid level at 20% pumpdown.
Movement of the seamless aluminum float rotates a magnet on the inner side of
the solid aluminum alloy head. The indicator pointer, or switch contacts, are on
the outer side and are operated by a small magnet which follows the position of
the inner magnet. There is no connection, except the magnetic field, between the
inside and outside. Internal gears and bearings are stainless steel.
In case of external damage, the indicator dial or switch cartridge may be replaced
from outside the refrigerant charge is not disturbed.
Switch Duty . . . . . . . . AC
Max. Volts . . . . . . . . . 120/240
Max. Amps . . . . . . . . . 1 (inductive)
Max. Watts . . . . . . . . . 75/150

Low Pressure
INDIC210A
High Pressure
INDIC452A

Liquid Level Indicator - Alarm


This indicatoralarm with selectable lowlevel point is designed for use in
applications where low liquid level protection is desirable. It provides a relay circuit
that closes at one of five user selectable levels of from 10 to 50%. The relay
circuit can be used to drive a variety of applications from alarms to pumps. The
indicatoralarm also provides a direct, visual indication of the liquid level in the
tank.
Each indicatoralarm uses highly reliable and accurate, three wire, voltage divider
technology to send the level signal to the level alarm, relay circuitry. The voltage
divider uses thick film element in conjunction with a multifingered contact to
ensure accuracy and reliability. The connector built into the indicatoralarm mates
with a standard Packard automotive type, rubber sealed connector for easy
installation and reliable connections.
Temperature . . . . . . . -20C to 70C (-4F to 185F), operating
Power Rating . . . . . . 5 amps, 240 VAC max.
Voltage Input . . . . . . 110 or 220 VAC
Gauge Mounting . . . . Rochester SeniorTM Adapter
UL Status UL recognized for refrigeration
All indicators require a factory installed flange and are available for 858 OD and
larger horizontal receivers, only. Flange cost is not included in cost of indicator
alarm.

68

Product Accessories

Menu
Product Accessories

Rotolock Adapters

SA Straight Adaptor IDS to Female Rotalock


Connections

coupling connection
ids connection

body

part
number

Body

A
(inches)

ids

coupling

3/8

3/416

SA03

7/8 hex

1 932

1/2

114

SA04

7/8 hex

1 732

5/8

114

SA05

7/8 hex

1 932

7/8

1 1/412

SA07

1 1/8 hex

1 2332

1 1/8

1 1/412

SA09

1 1/8 hex

1 3132

1 3/8

1 3/412

SA11

1 3/4 hex

2 716

part
number

A
(inches)

B
(inches)

AA03

1 516

1/2

AA Angle Adaptor IDS to Female Rotalock


Connections
ids
connection

ids

coupling

3/8

3/416

1/2

114

AA04

1 332

1732

5/8

114

AA05

1 332

1932

7/8

1 1/412

AA07

1 916

5/8

1 1/8

1 1/412

AA09

1 1316

1 3/8

1 3/412

AA11

2 316

coupling connection

BA Brass Adaptor IDS/ODS to Male Rotalock


Connections

thread connection

ids
ods

part
number

A
(inches)

ids

ods

thread

3/8

1/2

3/416

BA03x06

1 516

3/8

1/2

114

BA03x08

1 516

1/2

5/8

114

BA04x08

1 516

5/8

7/8

114

BA05x08

1 516

5/8

7/8

1 1/412

BA05x10

1 916

7/8

1 1/8

1 1/412

BA07x10

1 916

1 1/8

1 3/8

1 1/412

BA09x10

1 916

1 1/8

1 3/8

1 3/412

BA09x14

1 1116

1 3/8

1 5/8

1 3/412

BA11x14

1 1116

use with
thread

part
number

TS Teflon Fiber Seal for Rotalock Valves and Adaptors


Dimensions (inches)
A

ID

OD

ID

OD

716

916

116

3/416

TS-24590

5/8

3/4

116

114

TS-24591

7/8

116

1 1/412

TS-24592

1 3/8

1 1/2

116

1 3/412

TS-24593

valve and component notes

Steel valves and adapters with ids connections are


electrotin plated and can be silver soldered. The valve
stem packing can withstand considerable heat, but
should be kept as cool as possible. Valves should be
slightly open while soldering.
Teflon seals should be installed only after all soldering is
completed. A seal is furnished with each valve, adapter

or connection supplied on a vessel. Order additional seals for


replacement only.
Steel valves with flare connections are cadmium plated. The
stem packing will not withstand soldering temperatures, and
the valve body must be protected if soldering is done near the
valve.
69

Menu
Product Accessories

Safety Devices

Fusible Unions
Part number

Connections

temperature
setting

flare

mpt

union-184

3/8

3/8

212 F

union-319

3/8

5/8-18UNF

212 F

union-76

3/8

3/8

283 F

Fusible Plugs
Part number

thread size (mpt)

temperature setting

plug-148

1/8

212 F

plug-175

3/8

212 F

plug-265

5/8-18UNF

212 F

plug-166

1/8

283 F

plug-337

3/8

283 F

plug-364

5/8-18UNF

283 F

Relief Valves
Part number

3 9/16

1 3/8
1 5/8

Connections

pressure
setting

mpt

flare

valve-58

3/8

3/8

350 psi

valve-5026

3/8

3/8

600 psi

valve-5033

3/8

3/8

675 psi

valve-5040

1/2

5/8

600 psi

valve-5057

1/2

5/8

675 psi

valve-67

3/8

3/8

400 psi

valve-94

1/2

5/8

350 psi

valve-102

1/2

5/8

400 psi

valve-764

1/2

5/8

450 psi

valve-771

3/8

3/8

450 psi

valve-5064

3/4

3/4 FPT

600 psi

valve-5071

3/4

3/4 FPT

675 psi

Protection Notes

Relief valves are installed in a refrigeration system primarily to protect the vessel in the event of fire or other emergency high pressure condition.
Fusible unions and plugs protect only in the event of fire.
The 5/818UNF union or plug seats in a special 3/8" coupling with a copper zinc coated flare gasket, exactly as an SAE flare fitting. A
conventional 3/8" mpt pipe threaded union, plug, or safety valve will also seal on the dryseal pipe thread of the coupling if ever necessary.
All systems must have a relief valve or fuse plug installed in order to comply with the ANSI B9.1 code.

Sightglass

70

Part number

thread size

bullseye type

SG12

3/4 Rotalock 1 1/4 -12

float ball

Menu
Product Accessories

Brackets

BR compressor/condenser compressor/receiver mounting brackets for 6" to 20" diameter shells


Compressor/Condenser
15/16

.525 x 2.025 slots

2 1/16

(4) .4 x 1.9
slots

33/64
dia.

3 1/4

Part
number

4 3/4
B
1 3/4
1 3/4
4 3/4

Dimensions
(inches)
A

BR1

14

BR3

6 5/8

BR5

Part
number

Dimensions
(inches)
A

BR10

14

24

14

BR11

16

24

8 5/8

14

BR12

18

24

BR7

10 3/4

14

BR13

20

24

BR9

12 3/4

14

3 1/4
.525 x
2.025
(2) 5/8
slots
dia.
holes

3/4
2 1/2

Universal B condenser and receiver floor mounting brackets for 5" to 16" diameter shells
Universal
Part
F number

A
E
dia.
mtg
holes

5/8

Dimensions (inches)
A

5A

5 1/2

2 916

716

1 116

6A

5 1/2

2 916

716

1 116

6B

6 5/8

5 1/2

2 916

716

1 116

8B

8 5/8

2 78

716

1 116

10B

10 3/4

10

11

3 516

716

1 116

12B

12 3/4

11 5/8

13

4 1/8

916

1 1/2

14B

14

13 1/4

14 1/2

4 1/8

916

1 1/2

16B

16

15 3/4

17

4 1/8

916

1 1/2

Note: Two brackets are required for most applications

71

Purchase Order Terms and Conditions - Warranty information from Alfa Laval
(a) For new Equipment only, we warrant to you that the Equipment that is the subject of this
sale is free from defects in design (provided that we have design responsibility), material and
workmanship. The duration of this warranty is twelve (12) months from delivery to you (the
"Warranty Period"). If you discover within the Warranty Period a defect in design, material
or workmanship, you must promptly notify us in writing. Within a reasonable time after such
notification, we will correct any such defect with either new or used replacement parts, at our
option. Such repair, including both parts and labor, is at our expense.
(b) For repairs, parts and service provided by us, we warrant to you that the repairs parts and
service we provide to you will be free from defects in material and workmanship. The duration of
this warranty is ninety (90) days from as applicable (i) the date the machine which required the
repairs, parts or service is returned to you by us, (ii) the date of your receipt of the part, or (iii) the
date of repair, if performed at your facility. If during this ninety day period you discover a defect in
the repairs, parts or service you must promptly notify us in writing.
(c) All warranty service is subject to our prior examination and approval and will be performed by us
at your facility or at service centers designated by us. All transportation to and from the designated
service center will be at our expense. If we are unable to repair the Equipment to conform to the
warranty after a reasonable number of attempts, we will provide, at our option, one of the following:
(i) a replacement for such Equipment, or (ii) full refund of the purchase price. These remedies are
your exclusive remedies for breach of warranty. Unless otherwise agreed in writing by us, our
warranty extends only to you and is not assignable to or assumable by any subsequent purchaser,
in whole or in part, and any such attempted transfer shall render all warranties provided hereunder
null and void and of no further force or effect.
(d) We will use all reasonable efforts to obtain for you any manufacturer's guarantees or warranties
for any sub-assemblies included in the Equipment. To the extent such warranties are assignable,
we hereby assign to you all warranties that are granted to us by our suppliers of any subassemblies contained in the Equipment.
(e) The warranties set forth above are inapplicable to and exclude (i) any product, components
or parts not manufactured by us or covered by the warranty of another manufacturer, (ii) damage
caused by accident or the negligence of you or any third party, normal wear and tear, erosion,
corrosion or by disasters such as fire, flood, wind and lightning, (iii) damage caused by your failure
to follow all installation and operation instructions or manuals or to provide normal maintenance, (iv)
damage caused by unauthorized or improper installation of attachments, repairs or modifications,
(v) damage caused by a product or component part which we did not design, manufacture, supply
or repair, or (vi) any other abuse or misuse by you or any third party.
(f) If a warranty claim is being made, please contact Customer Service for a RGA form to be
completed. Goods returned without a RGA will not be accepted.

Das könnte Ihnen auch gefallen