Beruflich Dokumente
Kultur Dokumente
Application Handbook
THERMOPLASTICS
This application booklet presents selected application examples. The experiments were conducted with the utmost care using the instruments specified in the description of each application. The results were evaluated according to the current state of our knowledge. This does not however absolve you from personally testing the suitability of the examples for your own methods, instruments and purposes. Since the transfer and use of an application is beyond our control, we cannot of course accept any responsibility. When chemicals, solvents and gases are used, general safety rules and the instructions given by the manufacturer or supplier must be observed.
TM
All names of commercial products can be registered trademarks, even if they are not denoted as such.
THERMOPLASTICS
Page 1
THERMOPLASTICS
Page 3
Contents
PREFACE TO THE FIRST EDITION, 1997 ......................................................................................3 PREFACE TO THE SECOND EDITION, 2002 .................................................................................3 CONTENTS ............................................................................................................................................4 APPLICATIONS LIST ..........................................................................................................................6 1. INTRODUCTION TO THERMAL ANALYSIS ........................................................................10 1.1. DIFFERENTIAL SCANNING CALORIMETRY (DSC) ........................................................................10 1.1.1. Conventional DSC ..............................................................................................................10 1.1.2. Temperature-modulated DSC.............................................................................................11 1.2. THERMOGRAVIMETRIC ANALYSIS (TGA) ...................................................................................12 1.3. THERMOMECHANICAL ANALYSIS (TMA) ...................................................................................13 1.4. DYNAMIC MECHANICAL ANALYSIS (DMA) ................................................................................14 1.5. SIMULTANEOUS MEASUREMENTS WITH TGA (SDTA AND EGA)...............................................16 1.5.1. Differential thermal analysis (DTA, SDTA) .......................................................................16 1.5.2. Evolved gas analysis (EGA) ...............................................................................................17 2. STRUCTURE AND BEHAVIOR OF POLYMERS ..................................................................19 2.1. SOME DEFINITIONS IN THE FIELD OF POLYMERS ..........................................................................19 2.2. PHYSICAL STRUCTURE OF POLYMERS .........................................................................................20 2.3. THERMOPLASTIC POLYMERS.......................................................................................................21 2.3.1. Amorphous plastics.............................................................................................................21 2.3.2. Semicrystalline plastics ......................................................................................................22 3. IMPORTANT FIELDS OF THERMOPLASTIC POLYMERS ..............................................23 4. APPLICATION OVERVIEW OF THERMOPLASTIC POLYMERS ...................................24 5. TABLE OF CHARACTERISTIC TEMPERATURES OF THERMOPLASTIC POLYMERS ...................................................................................................................................25 6. PROPERTIES OF IMPORTANT THERMOPLASTIC POLYMERS AND TYPICAL TA APPLICATIONS..................................................................................................26 6.1. POLYETHYLENE, PE ...................................................................................................................26 6.2. ETHYLENE/VINYLACETATE COPOLYMER, E/VAC ......................................................................26 6.3. POLYPROPYLENE, PP..................................................................................................................26 6.4. POLYSTYRENE, PS......................................................................................................................27 6.5. POLYVINYL CHLORIDE, PVC ......................................................................................................27 6.6. POLYVINYL ACETATE, PVAC.....................................................................................................28 6.7. POLYAMIDE, PA .........................................................................................................................28 6.8. POLYETHYLENE TEREPHTHALATE, PET .....................................................................................28 6.9. POLYCARBONATE, PC ................................................................................................................29 6.10. POLYOXYMETHYLENE, POM......................................................................................................29 6.11. POLYTETRAFLUOROETHYLENE, PTFE........................................................................................29
Page 4
THERMOPLASTICS
7. APPLICATIONS OF THERMOPLASTICS ..............................................................................30 7.1. MEASUREMENTS ON POLYETHYLENE ..........................................................................................30 7.2. MEASUREMENTS ON POLYPROPYLENE BASED MATERIAL ............................................................55 7.3. GLASS TRANSITION OF POLYSTYRENE .........................................................................................64 7.4. TA MEASUREMENTS ON POLYVINYL CHLORIDE ..........................................................................68 7.5. POLYAMIDES AND THEIR BLENDS................................................................................................78 7.6. THERMAL BEHAVIOR OF POLYETHYLENE TEREPHTHALATE.........................................................97 7.7. MEASUREMENTS ON OTHER POLYMERS ....................................................................................105 7.8. THERMOPLASTIC ELASTOMERS .................................................................................................121 7.9. POLYMER BLENDS AND COPOLYMERS .......................................................................................125 7.10. FURTHER MEASUREMENTS OF THERMOPLASTICS AND THEIR PRODUCTS ...................................137 LITERATURE ....................................................................................................................................147 SUBJECT INDEX...............................................................................................................................148
THERMOPLASTICS
Page 5
Page 24
THERMOPLASTICS
PE-LD and PE-LLD as pellets, PE-HD as a film. Measuring cell: Pan: DSC821e with air cooling
(-CH2-CH2-)n
Conditions
Sample preparation: PE-LD: Disk of 9.796 mg cut from pellet PE-LLD: Disk of 8.128 mg cut from pellet PE-HD: Disk of 10.314 mg punched from film DSC measurement: Atmosphere: Heating from 30 to 180 C at 10 K/min Static air
Evaluation
Page 30
THERMOPLASTICS
Note: Two values can be used to characterize the peak temperature: the extrapolated intersection point of the inflection tangents, and the maximum of the DSC curve. The extrapolated peak temperature is not influenced so much by the arbitrary shape of the peak where random noise may cause the actual maximum to differ slightly from run to run, leading to an irreproducible peak temperature. For this reason the reproducibility of the extrapolated value is usually better.
Interpretation
The melting peaks are typical for the three different PE qualities with their distinctive peak temperatures. The peak temperature of the DSC melting curve is the most frequently determined property of semicrystalline polymers. It is the key parameter for processing and serves generally for identification.
Conclusion
THERMOPLASTICS
Page 31
PE-LD and PE-LLD as pellets, PE-HD as a film Measuring cell: Pan: DSC821e with air cooling Aluminum standard 40 l, lid hermetically sealed
Sample preparation: PE-LD: Disk of 9.796 mg cut from pellet PE-LLD: Disk of 8.128 mg cut from pellet PE-HD: Disk of 10.314 mg punched from film DSC measurement: Atmosphere: Heating from 30 to 180 C at 10 K/min Static air
Evaluation
Note: A straight baseline has been used for integration. Since the normalized value is used, it is important that the sample weight is accurate.
Page 32
THERMOPLASTICS
Interpretation
The area under the peak corresponds to the heat of fusion of the sample. It is proportional to amount of crystallites present in the sample. The degree of crystallinity is determined by comparing the measured heat of fusion with the theoretical heat of fusion of 100% crystalline polyethylene of 293 J/g (see table on page 25). The DSC crystallinity indicates the percentage of the material that is crystalline versus amorphous. The degree of crystallinity depends on how regular the structure of the molecule is (no branches or short branches in regular distance) and on the thermal history. Since hardness and strength increase with increasing crystallinity, the DSC result correlates with the mechanical properties.
Conclusions
THERMOPLASTICS
Page 33
Lupolen 4261 pellets and a molded part said to be Lupolen 4261 Measuring cell: Pan: DSC measurement: DSC821e with air cooling Aluminum standard 40 l, pierced lid Elimination of thermal history: 25 to 200 C at 10 K/min, then cooling at 5 K/min. Actual measurement: second heating run from 25 to 200 C at 10 K/min Nitrogen, 50 cm3/min
Atmosphere:
Evaluation
Lupolen 4261 Heat of fusion in J/g Peak temperature in C Peak width in K Fraction melted at 80 C in % 100 C in % 120 C in % 140 C in % 152.0 131.0 10.9 1.8 6.8 24.5 99.8
Page 34
THERMOPLASTICS
Interpretation
The melting behavior is characterized by the heat of fusion, the peak temperature and the peak width at half height (all 3 values together) or by the conversion curve. The conversion curve, also called the fraction melted, is a measure of the percentage of crystallites that has melted at the particular temperature. It can be presented in a tabular or graphical form. In contrast to the degree of crystallinity, conversion is a relative value and is therefore practically independent of weighing uncertainties. The balance used for this work had a resolution of 0.1 mg. An uncertainty of 0.3 mg can for example lead to a 6% error in the calculated value of the heat of fusion and hence in the degree of crystallinity. The melting behavior of the two samples is similar. The main difference is seen in the heat of melting. The crystallization behavior of the samples is compared on the next page.
Conclusion
THERMOPLASTICS
Page 35
Lupolen 4261 pellets and a molded part said to be Lupolen 4261 Measuring cell: Pan: DSC measurement: Atmosphere: DSC20 Aluminum standard 40 l, pierced lid Melting the sample by heating to 200 C at 10 K/min. Actual measurement: cooling from 200 to 25 C at 10 K/min Nitrogen, 50 cm3/min
Evaluation
Lupolen 4261 Onset of crystallization in C Peak temperature in C Peak width in C Heat of crystallization in J/g 116.8 112.9 5.9 145.0
Page 36
THERMOPLASTICS
Interpretation
The crystallization behavior is characterized by the crystallization onset, the peak width and the heat of crystallization. In addition, the conversion curve and table are useful for comparison purposes. The crystallization behavior of the two samples is similar. The melting behavior of the same samples is compared in the previous experiment. The heats of crystallization differ by about the same amount as measured before in the melting experiment.
Conclusion
THERMOPLASTICS
Page 37
Vestolen A 6017, Stamylan HD 7771, NCPE 2233, Finathene 58070, Lupolen 4261 Measuring cell: Pan: DSC measurement: Atmosphere: DSC20 Aluminum standard 40 l, pierced lid Heating from 30 to 200 C at 10 K/min Nitrogen, 50 cm3/min
Evaluation
Name
Crystallinity in %
Vestolen A 6017 Stamylan HD 7771 NCPE 2233 Finathene 58070 Lupolen 4261
Note: For clearness, only the Vestolen curve is evaluated in the diagram.
Page 38
THERMOPLASTICS
Interpretation
The DSC curves of all samples begin to deviate from baseline between 50 and 60 C. The signal returns to the baseline between 145 and 160 C. The DSC melting peaks of PE-HD of different quality show characteristic differences. To eliminate effects due to individual thermal history, the samples should have been pre-melted and recrystallized at 10 K/min. In addition, the sample masses should be more uniform, e.g. 5 2 mg. The peak width in particular depends on the sample mass (increasing mass increasing melting time broader peak) .
Conclusions
THERMOPLASTICS
Page 39
PE-HD film Measuring cell: Pan: DSC measurement: DSC821e with air cooling Aluminum standard 40 l, lid is hermetically sealed Pretreatment: annealing for 60 min at 129 C followed by cooling to 40 C at 5 K/min Heating from 40 to 180 C at 5 K/min (see curve of PEHD annealed at 129 C), then cooling from 160 to 40 C at 5 K/min Second heating run from 40 to 180 C at 5 K/min (see curve of PE-HD with thermal history eliminated) Static air
Atmosphere:
Evaluation
The melting gap can be evaluated as an onset, or the melting behavior can be characterized by the conversion curve. However, the most important information it reveals is the temperature at which annealing was performed.
Page 40
THERMOPLASTICS
Interpretation
Crystallite segregation occurs during annealing at 129 C: Small crystallites melt and recrystallize to form crystallites with melting points above 129 C. Crystallites with melting points of 129 C or lower cannot of course be formed during this process. As the sample is cooled, small crystallites with lower melting points form again, but a gap at 129 C (called the melting gap) appears in the second heating run of the sample. On complete melting, any thermal history is eliminated. The shape of the DSC melting curve depends on the thermal history of the sample. The melting gap is often used to check that the processing temperature was correct, e.g. the annealing of PE high voltage cables. Complete melting eliminates any thermal history and is a prerequisite for the comparison of different raw materials.
Conclusions
THERMOPLASTICS
Page 41
Two different types of tubing for automobiles and recycled material said to be PE-HD Measuring cell: Pan: DSC measurement: Atmosphere: DSC20 Aluminum standard 40 l, pierced lid Heating from 30 to 250 C at 10 K/min Nitrogen, 50 cm3/min
Evaluation
Crystallinity in % Defective tubing Good tubing Recycled material 57.8 55.7 57.7
Page 42
THERMOPLASTICS
Interpretation Conclusions
The DSC melting curves of all three samples are characteristic for PE-HD. The DSC melting curve allows PE-HD to be clearly identified. The defective tubing is also made of the correct material. To eliminate the effects of thermal history, the samples should be premelted and then cooled at identical rates, e.g. 10 K/min. Recycled material is not delivered in properly labeled original manufacturers packaging material. It is therefore very important to confirm that the polymer is the right material. The recycled material must also be checked to make sure that the initial processing and the recycling did not degrade the quality to any significant extent.
THERMOPLASTICS
Page 43
Noticeably brittle and distorted sheets, said to be made of PE-HD Measuring cell: Pan: DSC measurement: Atmosphere: DSC20 Aluminum standard 40 l, pierced lid Heating from 30 to 200 C at 10 K/min Nitrogen, 50 cm3/min
Evaluation
The heat of fusion determined for the PP peak (14.3 J/g) allows the approximate content of PP to be calculated. If the heat of fusion of pure PP is taken to be 60 J/g (typical for polypropylene), then the content is given by: Content = H/HPP100%, i.e. 23.9%.
Interpretation
The melting curve clearly shows that the material is a blend of PE-HD (peak temperature of 135 C) and PP (peak temperature of 163 C) and not pure PE. DSC proves that the material does not match the quality agreed upon. The supplier therefore replaced the sheets free of charge.
Conclusion
Page 44
THERMOPLASTICS
Lupolen 1800 S and Lupolen conz. SL 020 A as pellets Measuring cell: Pan: DSC measurement: Atmosphere: DSC20 Aluminum standard 40 l, pierced lid Heating from 30 to 250 C at 10 K/min Air, 50 cm3/min
Evaluation
Lupolen 1800 S Crystallinity in % Peak temperature in C Onset of oxidation in C Sample mass in mg 29.2 108.9 220.0 19.5
THERMOPLASTICS
Page 45
Interpretation
The DSC melting curves have the typical shape for PE-LD. The exothermic reaction above 200 C is due to the onset of oxidation. Evaluation of the percentage crystallinity and peak temperature reveal that these two samples are of similar quality and that both are PE-LD. The onsets of oxidation around 220 C indicate they are processing stabilized because the onsets are slightly higher than that expected for basic PE. Lupolen 1800 S is more stable than the other sample. Further stabilization could be achieved by adding additional antioxidants. This could shift the onset to as high as 260 C.
Conclusions
Page 46
THERMOPLASTICS
Lupolen GM5040 T12 (stabilized PE-HD film) Measuring cell: Pan: DSC821e with air cooling and gas controller Aluminum standard 40 l without lid, 40 l copper pan without lid, for comparison According EN 728 (European standard): Under nitrogen, 50 cm3/min 3 min isothermal at 30 C, then heating to 200 C at 20 K/min, 2 min isothermal at 200 C. Under oxygen, 50 cm3/min (automatically switched by the gas controller): Isothermally at 200 C starts the actual measurement. Since only the onset of oxidation is required, the actual measurement time can be reduced using the Conditional Experiment Termination software option. Nitrogen and oxygen, respectively, automatically switched by the gas controller
Atmosphere:
Evaluation
The oxidation induction time (OIT) in the aluminum pan is 15.9 min, in the copper pan 9.5 min. The melting curve could also be evaluated.
THERMOPLASTICS
Page 47
Interpretation
The time after switching to oxygen to the onset of oxidation (intersection of baseline with the tangent) is called the induction period or Oxidation Induction Time, OIT. A long OIT indicates good stability and vice versa. Contact with copper or copper alloys catalyzes the oxidation reaction. Polyolefins that will be exposed to copper require special additives that neutralize this catalytic effect. The efficiency of such additives is determined by carrying out the experiment with the sample in a copper pan. Good copper stability results in an OIT of at least half the value obtained in the aluminum pan. Without such additives, the OIT is about 10 times shorter in copper pan. Note: Polyolefines give distinct induction periods. Other polymers are best tested by exposure to oxygen on heating at relatively low rates, preferably 5 K/min, until distinct exothermal oxidation is visible.
Conclusion
The determination of the oxidative stability by DSC is fast and easy. It is especially recommended for the quality assurance of long-life goods such as electrical cables and water pipes. Each batch of the raw material should be measured. In addition, the polymer can be identified from the fusion peak obtained.
Page 48
THERMOPLASTICS
Cross-linked polyethylene sheet Measuring cell: Pan: TMA40 with 3-mm ball-point probe The sample is measured between fused silica disks of 6-mm diameter and 0.5-mm thickness
Sample preparation: A rectangular sample of about 4x4 mm is cut off with a knife. The height of the sample, 5.1 mm, is the same as the thickness of the original sheet TMA measurement: A first heating run to 150 C at 10 K/min eliminated the thermal history. After uncontrolled cooling to 25 C, the measurement was performed at a heating rate of 10 K/min. Note: the pretreatment was also done under dynamic load. Load: Atmosphere: Periodically changing every 6 s between 0.01 and 0.19 N Static air
Evaluation
The elastic deformation of 1.9% in the amorphous state allows the complex Youngs modulus, E, to be calculated as follows: E = F/(ALr), where F is the change in force, A the cross-sectional area of the sample, and Lr the relative change in length (1.9%). E = 0.18 N/(44 mm20.019) = 0.59 N/mm2. The onset of the difference of the envelopes at 99.6 C is related to the crystallite melting.
THERMOPLASTICS
Page 49
The expansion coefficients derived from the slope of the upper envelope (load 0.01 N) are: between 40 and 50 C, semicrystalline 275 ppm/K between 120 and 130 C, amorphous 353 ppm/K
Interpretation
Cross-linked polyethylene below the crystallite melting range is rigid, just like standard PE. When the crystallites melt the volume increases and the properties become rubbery-like. There is an elastic deformation of approx. 1.9% caused by the varying force. The distance between upper and lower envelopes is proportional to the compliance (1/E). The overall slope of the curve envelope reflects the expansion of the sample. Note: PE that is not cross-linked would be squeezed out between the disks after melting (plastic deformation).
Conclusions
The thermomechanical properties of cross-linked polyethylene above the crystallite melting range are completely different to those of normal PE. Instead of viscous flow there is rubbery elastic behavior. The cross-linked macromolecules prevent plastic deformation.
Page 50
THERMOPLASTICS