Sie sind auf Seite 1von 22

Monitoring Relays

Voltage Monitoring Current Monitoring Mains Monitoring Isolation Monitoring Thermo Protection Relay

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

111

KAT 2008

Monitoring Relays

Monitoring Relays
Co nta c Se rie s t et

Voltage Monitoring

Undervoltage Monitor Undervoltage Monitor Overvoltage and Undervoltage Monitor DC Voltage Monitor AC or DC Voltage Monitor Precision DC Voltage Monitor RMS Precision AC/DC Voltage Monitor

MV52 MV62 MV53 CT524 CUEBU SSU2...


(SSU11)

So ck

DIN 35 DIN 35 DIN 35

6 A 114 6 A 114 6 A 115 6 A 116

DIN 35

8 A 117 5 A 118 5 A 118

SSU7...

Current Monitoring

Overvoltage Monitor Undervoltage Monitor Overvoltage and Undervoltage Monitor Current Transformer DC Current Monitor (200 mA) DC Current Monitor (2 A) DC Current Monitor (6A) AC or DC Current Monitor

EOCR-AR DIN 35 EUCR-BR DIN 35 ECR-3D DIN 35

3 A 120 3 A 120 3 A 120 122 6A 123 6 A 123 6 A 123

SRCT-35 DIN 35 CT512 CT515 CT516 CUEBI DIN 35

8 A 124

Mains Monitoring

Three-phase Monitor (50 Hz) Three-phase Monitor (50 Hz) Three-phase Monitor (60 Hz) Phase-sequence Monitor

SSU33 SSU34 SSU36 SSU31 DIN 35 DIN 35

6 A 126 5 A 127 5 A 127 6 A 128

Isolation Monitoring

Isolation Monitor

ESU-D2

DIN 35

5 A 130 5A

Thermo Protection Relay

Motor Thermo Protection Relay

TSR19

5A 132 5A

112

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

Pa ge

Monitoring Relays

Voltage Monitoring

4
V
V V

DIN

11

Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:

www.comat.ch

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

113

KAT 2008

Monitoring Relays

V
and otheres: www.comat.ch

Undervoltage Monitor

MV 52 (50Hz) MV 62 (60Hz)

al ok 12 12

A2

A1

L N

13mm
MV52 (50Hz), MV62 (60Hz)
U SET (V)
supply
14 11 12
gn ye

VA
t t
gn

ok
fail rd alarm

al

rd

The MV52 (50Hz) or MV62 (60Hz) protects control systems, contactors and motors during undervoltage against thermal overload and malfunctions. The monitoring can be set precisely in volts from U N 30% up to U N. The switching off or on again follows delayed by 0,1/0,5 or 1second. 2 LEDs show the definite monitoring status.

ok

V Setting range Hysteresis t (fail-al-ok) Switching current/voltage Switch rating Mechanical switching cycles

Data at Tamb. = 20 C

0,7 ( 30%) U N ...U N 5% 0,1/0,5/1s

6A 250V A 1500VA/...180W 30x10 6

Voltage tolerance Power consumption Ambient temperature

... U N +15% 3,5VA,1W (25)10...+60 C

BS13-K BS13-G
(incl.paper)

TS35

45

90

Order-Nr.

Zu schtzende Anlageteile Installation protger Installation to be protected

11

14

50 Hz
11 44 13

60 Hz
MV62 /AC120 V

Accessories Label (5Piece) Label (5Piece)

BS13-G BS13-K

MV52 /AC 230 V MV52 /AC115 V

114

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

V
and otheres: www.comat.ch

Overvoltage and Undervoltage Monitor

MV 53

+ 0%

+ 2,5% + 5 % + 7,5 % +10 % +12,5% +15 % +17,5 %

230V 115 V

236V 118 V

241V 121V

247V 124 V

253V 127 V

258V 129 V

265V 132 V

270V 135 V

al

ok

Alarm threshold value


0% 5% 10 % 15 % 20% 25% 30% 35%

A2 A2 A1
230V 115 V 219 V 109 V 207V 103 V 195 V 97V 184 V 92V 173 V 86V 161V 80V 150 V 74V

L N

Never set both thresholds on 0 % !

V O1 V O2 V NOM V U2 V U1

HYST.

HYST.

tO
ok al
fail rd

tR
ok

tO

tR

The MV53 (50/60Hz) protects single phase consumers in AC networks from over- and undervoltage. Overvoltage and undervoltage thresholds can be set independently in percentage of the nominal voltage using two DIP-switches (see diagram above). Using a potentiometer allows setting an alarm delay of 25ms...2,5s. A two-colored LED shows the definite monitoring status.

11

supply

14 12

al

gn

ok

ye

alarm

4
V Setting range overvoltage Setting range undervoltage Hysteresis t O Alarm delay t R Reset time Switching current/voltage Switch rating Mechanical switching cycles
Data at Tamb. = 20 C

t O : Alarm delay t R : Reset time

U Nom + 2,5...17,5% U Nom 35... 5% 2,5% 25ms...2,5sec 70ms

6A 250V A 1750VA/...170W 2x10 7 U N 35%... +17,5% 3,5VA,2W (25)10...+60 C

Voltage tolerance Power consumption Ambient temperature

987

65

TS35

90

Order-Nr.
50/60 Hz

70

22,5

MV53 /AC 230 V MV53 /AC115 V

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

115

KAT 2008

Monitoring Relays

MV53

Zu schtzende Anlageteile Installation protger Installation to be protected

12 11 14

32

10

V
and otheres: www.comat.ch

DC Voltage Monitor

CT 524

Socket C12B0

Relay C32/DC24V

Type CT524.2/DC24V

Module CT524/DC24V

CT524
2 1
supply

Economy DC Voltage Monitoring Relay


[V]
with 3 twin changeover contacts. 4 functions can be selected: Overvoltage/undervoltage monitoring with adjustable hysteresis or 2 range monitors (INT or EXT). Adjustable alarm delay. LED display for errors and ok. Contact inspection window at the top. Manual safety operation.
R
10 A2

9 8 7 5 3 4
2 CT B1 A1

10 11

6 V in

1 12 2

MAX

+
R

t R fail
ok al

Input resistance 12 10: 100k


+

DC24V

MIN

tR
R

fail ok al

t
Alarm delay t Reset time t R Switching current/voltage Switch rating Mechanical switching cycles

Data at Tamb. = 20 C

INT

0,1/0,5/2s 100ms

t
R

tR

t R fail
ok al
6A 250V A 1500VA/...200W 100 x10 6

EXT

tR
R
gn ok ye fail rd

tR

fail ok al

Voltage tolerance Power consumption Ambient temperature

0,8 -1,2UN 0,5W 25...+60 C

alarm

Order no. Range U max


10%

Accessories

Socket 0-30 V
Socket and Accessories: Page 97

C12 B0

40 V

CT 524.2 / DC24 V

Type No. = Module + Relay (FS-C, HF-32 incl.)

116

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

V
and otheres: www.comat.ch

Voltage Monitoring AC or DC

CUEBU

L N (+) U

AC230V 50/60Hz Pv 4VA Input 5-9

AC 15 ...480 V DC 15 ...700 V
Ri 1M

2 4 6

10

8A 250V A

Functions
Up
Hys

CUEBU 15 -700
Monitoring Relay
for AC or DC voltages ranging from AC15...480V, DC15...700V. LCD display for the measured value and the parameter setting. LED indication for the alarm status. Snap on to DIN-rail TS35 conform DIN (43880).
[V]

Up

t1

fail ok al M

R
Supply

[V]
Hys

Lo
Lo

t1

fail ok al M Up [V] Lo

4
V
Data at Tamb. = 20 C

R
Supply

Hys
Up / Lo

t1

t1

fail ok al M

Monitoring range Hysteresis Input resistance Ri Display/Accuracy

AC15...480V, DC15...700V 5...50% 1M xxxV/2% 1digit 0,1...12s

t
Alarm delay time t1 Switching current/voltage Switching power AC1 Output contact

R
Supply

gn

ok

ye

fail

rd

alarm

8A 250V AC1 /...240W 2000VA /...240W 1x u, AgNi

Operation voltage AC50/60Hz Power consumption Pmax Isolation Temperature: operating/storage

AC230V +10%; -15% 50/60Hz 4,5VA/2,5W 3kV rms /1min -20...+55 C /-40...+70 C

Order-Nr.
50/60 Hz

CUEBU15-700 / AC 230 V

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

117

KAT 2008

Monitoring Relays

V
and otheres: www.comat.ch

Precision DC/RMS Voltage Monitoring Relay

SSU11 /... SSU2x /... SSU7x /...

RL

9 8 7 5 3 4
DC 10-32V

Um

()
L+ N

10 11

6 1 2

35 mm

U SET U SET U SET U SET

FAIL OK OK FAIL

SSU11/...; SSU2x/...; SSU7x/...


The SSS11, SSU2x and SSU7x are high precision voltage monitoring relays for DC or RMS AC/DC with interactive front operation and display of values and voltmeter function. Two values for FAIL and OK can be programmed. With this, the hysteresis is automatically given. Depending of the programmed values the over- or undervoltage monitoring function is defined. Fixed max. and min. values are given for alarm triggering. However, the min. value monitoring can be disabled. The measuring input is galvanically isolated from the power supply (2-10). High EMC immunity design and self diagnostic features guarantee very high reliability and a long service life. Applications are for example monitoring of battery voltage in industrial installations.

supply

t fail

t ok
normal fail delay alarm

supply 3s: + LEDs

11

9 8
ye rd

ok al
meas. alarm

Selection of type For DC measurement For RMS AC/DC

50mA

(+)

Type SSU 2x / UC...V SSU 7x / UC...V

gn

ok

F Measurement range (x) Measurment range Adjustment range Resolution t fail, t ok

9
0 - 210mV 0,1 - 200mV 0,5mV

2
0 - 38V 0,1 - 35V 20mV

5
0 - 157V 40 - 150V 100mV

6
0 - 285V 0*/50 - 270V 0,5V *SSU76

0 - 38V 0 - 77V 0,1 - 10V 10 - 75V 20mV 100mV 0,1s - 600s

Power supply Power supply tolerance Ambient temp

UC110-240V U -20% +10%

UC60-127VU UC24-48V U -20% +26% -20% +55% +10...+50 C (-25...+60 C)

UC12-15V U -25% +33%

Switching current/voltage

1 x co 5A, 250 V; 1 x no Transistor NPN, DC50mA, 24V

Example of order SSU DC 0-38V/UC24-48V: SSU23/UC24-48V SSU RMS AC/DC 0-200mV/UC110-240V: SSU79/UC110-240V

Accessories Socket: Retaining clip:

C11-A HF-24 Frontpanel mounting: FZ-23

Attention: P/O numbers of several devices were changed (refer below). Devices are identical. Old number: SSU11/UC110-240V SSU11/UC60-127V SSU11/UC24-48V SSU11/UC12-15V
Socket and Accessories: Page 97

Replaced by: SSU26/UC110-240V SSU25/UC60-127V SSU24/UC24-48V SSU23/UC12-15V

Old number: SSU12/...V SSU13/...V SSU14/...V SSU16/...V

Replaced by: SSU22/...V SSU23/...V SSU24/...V SSU26/...V

118

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

Monitoring Relays

Current Monitoring

4
A
A

DIN

1 1

Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:

www.comat.ch

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

119

KAT 2008

Monitoring Relays

A
and otheres: www.comat.ch

Current Monitoring Relays

EOCR-AR -05 -30 EUCR-BR -60


1

LOAD 2
2

OP JUST LO

IT

Setting ranges
[A]
1x 2x 3x 4x 5x

-05 0,5-6 0,25-3 0,17-2 0,13-1,5 0,1-1,2 -30 2,5-30 1,25-15 0,83-10 0,62-7,5 0,5-6 -60 5-60 2,5-30 1,7-20 1,25-15 1-12

EOCR-AR EUCR-BR

A A tO
supply

tO

tR

1/2

L (+) U B N

al

SCHTZ CONTACTOR

15

18 16
gn ok ye fail rd

ok al
alarm

EOCR-AR / EUCR-BR
1 fail

or

2 fail

= FAIL

The EOCR-AR and the EUCR-BR monitor overcurrent and undercurrent on AC power circuits. One or two current paths can be monitored directly up to 60(75)A, by means of the integrated current loop transformers. The adjustable alarm delay ( t O) and the automatic alarm resetting ( t R) permit universal usage in motor and transformer protection systems, monitoring of electrical heating elements and in the control of pumps, ventilation systems, suction and feed devices. The nominal monitoring range in the 3 types -05/-30/-60 can be altered by multiple looping of the conductor (see schedule above).

al ok

A2 A1 15 16 18

+L
N

t
Alarm delay t O Reset time t R Switching current/voltage Switch rating Mechanical switching cycles

Data at Tamb. = 20 C

0,3 - 30s 0,5 - 150s

3A 250V A 750VA/...90W 20x10 6

Voltage tolerance AC/UC Power consumption Ambient temperature

0,8-1,1/1,25 U N 3(5) VA /1W 20...+60 C

Order-Nr.
16
10 10

AC
50/60 Hz

UC (AC/DC)
05 30 60

20

05 30 60

Over current relay A2


24

A1

15

16

18 Under current relay

EOCR-AR- ... / AC 230 V EOCR-AR- ... / AC115 V EUCR-BR- ... / AC 230 V EUCR-BR- ... / AC115 V

EOCR-AR- ... / UC 24 V

EUCR-BR- ... / UC 24 V

62

54

120

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

A
and otheres: www.comat.ch

Current Monitoring Relays

ECR-3D
Setting ranges

-05 -60

L1

L2

[A]

1x

2x

3x

4x

5x

L3

-05 0,5-6,5 0,25 - 3,2 0,17- 2,1 0,13-1,63 0,1-1,3 -60 5 -75 2,5- 38 1,7-25 1,25-18,8 1-15

L1 or L 2 or L 3
0 U

L1+L 2 +L 3 off

A A

Phase sequence error

tO
supply

tR

tO

tR

R1

1 fail

or

2 fail

or

3 fail

= FAIL

R2
+

R1
al ok

al ok

A2 A1 26 25 28 16 15 18

The adjustable alarm delay ( tO) and the automatic alarm resetting ( tR) permit universal usage in automation and protection techniques. The set values are displayed automatically by setting the respective parameters. Triggered faults remain stored and displayed until reset.
1 2

+L
N

2
( L1) ( L2) ( L 3)

t
Alarm delay t O Reset time t R Switching current/voltage Switch rating Mechanical switching cycles Voltage tolerance AC /UC Power consumption Ambient temperature

Data at Tamb. = 20C

0,3 - 30s 1,0 - 120s / 3A 250V A 750VA/...90W 20x10 6 0,8-1,1/1,25 U N 3(5) VA /1,5W 20...+60 C

16

10

10

10

Order-Nr.
21

UC (AC/DC)
A2 A1 26 25 28 16 15 18

30

05 60

Current monitoring relays


5

ECR-3D-... / UC110-240 V ECR-3D-... / UC 24 V

71

70

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

121

KAT 2008

Monitoring Relays

dis t you to oduct is ill assis w This pr s t s li prodt specia te successor produc ia ECR-3D ppropr tion. d the a applica r finECR-3D u o y The is for monitoring overcurrent and r tact us on AC t fo onundercurrent c c u o t e t power circuits. sita he t up donof 60(75)A Three current to 60(75) A can be monitored directly ase paths le P by means of the inte-grated current loop transformers.

L UB N

TION Our N E T T A ed. (+ ) continu

15 25

18 16 28 26
gn ok ye fail rd alarm

R2

Current Transformers
and otheres: www.comat.ch

SRCT-35 - 50/ 5 A - 100/ 5A - 250/ 5A - 500/ 5A

SRCT-35
Current transformers of the SRCT-35 series transform high AC currents into proportional secondary current in the ratio 10:1 (type -50) up to 100:1 (type -500). With accuracy class 1, coupled with a large power reserve (PN: 2,5VA) and high overload capacity up to 150%, the SRCT-35 is the ideal transformer for general applications and for the use with Comat monitoring relays ..AR, ..BR, ..3D.

Power Accuracy Frequence range Operating voltage Overload Ambient temperature

2,5VA Class 1 50/60Hz 720V x 1,5 (Class 1,5) 5...+40 C

10

BEF 1
k

86

35

Direct mounting

Order-Nr.

UC (AC/DC)
FOR M4 38 40 4.3 3

50 100 250 500 1)

SRCT-35 - ... / 5 A
4,5 50 76 2 65

1) Other primary currents on request

122

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

A
and otheres: www.comat.ch

DC Current Monitor

CT 512 CT 515 CT 516

(200 mA) (2 A) (6 A)

Socket C12B0

Relay C32/DC24V

Type CT512.2/DC24V

Module CT512/DC24V

CT512,515,516
2 1
supply

Economy DC Current Monitoring Relay


[A]
with 3 twin changeover contacts. Without external shunt up to 6A. 4 functions can be selected: - Overcurrent/undercurrent monitoring with adjustable hysteresis or 2 range monitors (INT or EXT). - Adjustable alarm delay. - LED display for error and ok. Contact inspection window at the top. Manual safety operation. R
10 A2

9 8 7 5 3 4
2 CT B1 A1

10 11 RL

6
in

1 12 2

MAX

+
R

t R fail
ok al

DC24V

Voltage drop (2-12) CT512 : 300mV CT515 : 200mV CT516 : 100mV

MIN

tR
R

fail ok al

t
Alarm delay t Reset time t R Switching current/voltage Switch rating Mechanical switching cycles

Data at Tamb. = 20 C

INT

0,1/0,5/2s 100ms

t
R

tR

t R fail
ok al
6A 250V A 1500VA/...200W 100 x10 6

EXT

tR
R
gn ok ye fail rd

tR

fail ok al

Voltage tolerance Power consumption Ambient temperature

0,8 -1,2UN 0,5W 25...+60 C

alarm

Order no. Range max 10%

Accessories

Socket 0-200 mA 0-2 A 0-6 A


Socket and Accessories: Page 97

C12 B0

300 mA 3A 7A

CT 512.2 / DC 24 V CT 515.2 / DC 24 V CT 516.2 / DC 24 V

Type No. = Module + Relay (FS-C, HF-32 incl.)

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

123

KAT 2008

Monitoring Relays

A
and otheres: www.comat.ch

Current Monitoring AC or DC

CUEBI

L N (+) U

AC230V 50/60Hz Pv 4VA Input 5-9

AC 0,1A ...10 A DC 0,1A ...10 A


Imax.15A Ri 5m

2 4 6

10
8A 250V A

Functions
Up
Hys

CUEBI01-10
Monitoring Relay
for AC or DC currents ranging from 0,1A up to 10A with start-up delay. LCD display for the measured value and the parameter setting. LED indication for the alarm status. Snap on to DIN-rail TS35 conform DIN (43880).
[A]

Up

t2

t1

fail ok al M

R
Supply

[A]
Hys

Lo
Lo

t2

t1

fail ok al M Up [A] Lo

R
Supply

Data at Tamb. = 20 C

Monitoring range Hysteresis Input resistance Ri Display/Accuracy

AC/DC 0,1...10A 5...50% 5m xx,xA/2% 1digit 0,1...12s 0,1...20s

Hys
Up / Lo

t
Alarm delay time t1 Start-up delay t 2 Switching current/voltage Switching power AC1 Output contact

t2

t1

t1

fail ok al M

R
Supply

gn

ok

ye

fail

rd

alarm

8A 250V AC1 2000VA /...240W 1x u, AgNi

Operation voltage AC50/60Hz Power consumption P max Isolation Temperature: operating / storage

AC230V +10%; -15% 50/60Hz 4,5VA/2,5W 3kV rms /1min -20...+55 C /-40...+70 C

Order-Nr.
50/60 Hz

CUEBI 01-10 / AC 230 V

124

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

Monitoring Relays

Mains Monitoring

4
3

DIN

11

Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:

www.comat.ch

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

125

KAT 2008

Monitoring Relays

3
and otheres: www.comat.ch

Three-phase Monitoring Relay

SSU33 (50Hz)

1)

230V ( )

2)

400V ( )
6 A 250 VA 1500 VA/ ...270 W
ok alarm

L1 L2 L3 N 10
1) 2)

<
MIN

U
FIX

>
MAX
1 0,2 - 5 s ok al

t del
2

11 9 2

U, ,
PHASE SEQUENCE

fail red SSU33L gn

7 4 5

In case of a power failure the alarm is activated without delay!

SSU33L
The SSU33 (50Hz) provides comprehensive monitoring of three-phase mains supplies with or without neutral. The following mains faults are monitored: Error signal 1 U (V , V ): Exceeding or dropping below the fixed voltage values Umin/Umax for L1-N or L1-L2 (no differential voltage, phase position or frequency fault). Error signal 2 U, , : One or more of the three voltages, phase positions, phase sequence or the mains frequency are diverging from the required value. Depending on the nature of their occurrence -errors are evaluated cumulatively. Any error is signalled by the red LED and is reported after expiry of the set alarmdelay time ( t del 0,2...5s) via 7-4-5. In the correct status (ok) the green LED is illuminated (4-5 open, 4-7 closed).

3x 230 (400) V
1)

3x 400V
2)

L1 N L2 L3

L1 L2 L3

U
1

Overvoltage > (U max) Undervoltage

U U U U U U
/ Order no.

> 275V

> 480V

< (U min)
2

<160V
20 - 100V 35 - 173V 3-15/3-15Hz SSU33L/AC230V

< 280V
20 - 100V 35 - 173V 3-15/3-15Hz SSU33L/AC400V

Differential range

75

Accessories Socket Retaining clip Front mounting

C11A HF-24 FZ-23

C11A
Socket and Accessories: Page 97

38

126

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

3
and otheres: www.comat.ch

Three-phase Monitoring Relay

SSU34 (50Hz) SSU36 (60Hz)

DO NOT connect simultaneously: neutral conductor N and bridge L3-L!

<
N oder or L L3 L2 L1
MIN

MAX
1

t del
2 0,2 - 5 s

ok

al

fail red gn
ok alarm

U, ,
PHASE SEQUENCE
3

4 5 6 3 7 8

In case of power failure the alarm is activated without delay!

E The SSU34 (50Hz) and the SSU36 (60Hz) provide comprehensive monitoring of three-phase mains supplies with or without neutral. The following mains faults are moni-tored: Error signal 1 U (V , V ): Exceeding or dropping below the set voltage values Umin/Umax for L1-N or L1-L3,L (no differential voltage, phase position or frequency fault). Error signal 2 U, , : One or more of the three voltages, phase positions, or the mains frequency are diverging from the required value. Depending on the nature of their occurrence errors are evaluated cumulatively. Error signal 3 : Connection polarity reversal (wrong phase-sequence). Any error is signalled by the red LED "fail" and is reported after expiry of the set alarm-delay time ( t del 0,2...5s) (for error signal 3 undelayed) via 5-6 and 7-8. In the correct status (ok) the green LED is illuminated (5-6 and 7-8 open, 5-4 and 7-2 closed).

50Hz U
1

50Hz
230/400VA 235-275V 410-480V 160-225V 280-390V 20-100V 35-173V 3-15/3-15Hz SSU34 /AC400V

50Hz
290/500VA 300-350V 520-600V 200-280V 350-485V 20-100V 35-173V 3-15/3-15Hz SSU34/AC 500V

60Hz
120/208V A 125-145V 216-250V 85-115V 148-200V 10-50V 17-87V 5-24/3-22Hz SSU36/AC208V

60Hz
265/460V A 270-320V 470-550V 185-260V 322-450V 20-100V 35-173V 4-21/ 3-19Hz SSU36 /AC 460V

60Hz
277/480V A 284-232V 490-575V 194-270V 336-470V 20-100V 35-173V 4-21/ 3-19Hz SSU36 /AC480 V

Overvoltage > (U max) Undervoltage < (U min)

U U U U U U
/ Order no.

58/100VA 60-70V 105-121V 40-55V 70-95V 5-25V 10-50V 3-15/3-15Hz SSU34/AC100V

Differential range

Detachable Terminals

105

75

50

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

127

KAT 2008

Monitoring Relays

MAIN

ITORI N O M S

NG

SSU34, SSU36

5A 250VA 1250 VA/ ...150 W

>
SSU34/36

3
and otheres: www.comat.ch

Phase-sequence Monitoring Relay

SSU31

L1 L2 L3
Failure of L2 or L3 cannot be displayed (LED)!

SSU31
U
supply
7 4 5
gn ye

200ms

50ms

gn

ok
fail rd alarm

al

rd

The SSU31 serves as a phase-sequence, three-phase undervoltage and phase failure monitor. The monitoring function helps to ensure the correct rotation direction of pumps, motors and conveyors in mobile devices with connection to different power outlets. The defined undervoltage and phase failure protects against malfunction and damage caused by overheating.

9 8 7 5 3 4

ok
10 11

al
6 1 2 L1 L2 L3

ok

Data at Tamb. = 20 C

Supply Cut-off undervoltage Hysteresis Power consumption

...1,2 . U N U N 20% 3% / U N 10VA / 1,5W 6A 250V A 1500VA/...200W 30x10 6

Switching current/voltage Switch rating AC1/DC1 Mechanical switching cycles

Order no.
50/60 Hz

Accessories Relay socket Retaining clip Front mounting C11A HF-24 FZ-23

SSU31/AC 400 V SSU31/AC 208 V


Socket and Accessories: Page 97

128

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

Monitoring Relays

Isolation Monitoring

DIN

Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:

www.comat.ch

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

129

KAT 2008

Monitoring Relays

Isolation Monitor
and otheres: www.comat.ch

ESU-D2

ESU-D2

R MAX (AL1) R SET (AL2) R MIN

30k

supply

t del

t del

tR
1s

tR
1s

4k (Fix)

Output AL1 15 contacts

18 16
(38)

AL2
LEDs

(37)

25
gn

28 26

ok

ok
4k 30k

ye Scale

al

Trend

rd gn ye rd

al
ok meas. alarm

ESU-D2
The ESU-D2 monitors the isolation resistance in non-grounded DC-networks (24-48V D). Two alarm steps (prealarm AL1 and main alarm AL2) are indicated via separate output contacts. Settable alarm delay ( tdel): 0,1-10sec. Displays: bargraph-display of the measured earthing resistance 4...30k (green = ok). Two red LEDs show the ground tendency towards plus (+) or minus ( ). Measuring terminal 5V for the external display of the earthing resistance (0,1V/k ). Test functions: Periodic automatic check, also with key Test. Environmental failures: monitoring of AC-short circuit, overvoltage, ground interruption.

Zu berwachende Anlage Installation surveiller Installation to be monitored

DC 0..52V

E
0,1V/k

V
5V

Pre alarm

AL1
15 16 18

+
Data at Tamb. = 20 C

E2

+
0,1V/k

AL1 AL2

Measuring range Error of measurement Setting range AL1/AL2 Time of error-detection Alarm delay time settable Voltage stability + or /earth

1k...50k / 0...52VDC 10% 4-30k / 4k fix 800ms / 30k 0,1-10s AC250V

ESU-D2

(1mA 12V ) 5A 250V A

L E1 25 26 28 37 38

Switching current/voltage Switch rating Mechanical switching cycles

5A 250V A 1250VA/...150W 5x10 6

L (+) UB N

AL2
Main alarm

Connect E1, E2 separately on E.

Voltage tolerance AC/UC Power consumption Ambient temperature

U N 15% / U N 20% 2W (25) 0...50 (60) C

Only one ESU-D2 per DC network!

Detachable Terminals

75

Order no.

UC (AC/DC)
ESU-D2 / UC110-240 V ESU-D2 / UC 24-48 V

105

50

130

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

Monitoring Relays

Thermo Protection Relays

4
C
M

1 1

Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:

www.comat.ch

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

131

KAT 2008

Monitoring Relays

C
and otheres: www.comat.ch

Thermo Protection Relay

TSR19

or

TSR 19
R PTC /
supply
1-3 11-9
gn ok ye
-SWITCH

fail C/F 2,5s

RESET
gn

ok
fail rd alarm

al

rd

The TSR19 is intended to monitor the temperature of motor coils, generators and transfomers. It detects the temperature of the windings over the change in resistance of the PTC thermistors 1 or the position of the thermo switches 2 . The circuit is designed to detect a break in the continuity of the detection circuit and ground failures. On position PTC, line or sensor fault is also detected. Reset after failure detection: Press reset button or interrupt supply voltage for >200ms.

PTC
Sensor

Thermo Switch

9 8 7 5 3 4

al
A2

ok
A1

10 11
Data at Tamb. = 20 C

6 1 2

Sensor resistance R ok Sensor wire R max Error-detection R fail Sensor supply U 5-7 Sensor supply 5max

100..1800 ; 0..1800 20 R fail >2200 15V / R sens 3mA 5A 250V A 1250VA/...180W 30x10 6

Switching current/voltage Switch rating Mechanical switching cycles

Voltage tolerance Power consumption Ambient temperature

15/+10% 5VA 25...+60 C

75

Order no.

Accessories

UC(AC/DC)
50/60 Hz

TSR19 /AC 230 V TSR19 /AC115 V


C11A
Socket and Accessories: Page 97 38

TSR19 / UC 24 -48 V

Socket C11A Retaining clip HF-24 Frontpanel mounting: HF-23

The TSR19 replaces the types TSR17 and TSR18.

132

KAT 2008

This edition replaces all previous issues. Availability, errors and specication subject to change without notice.

COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch