bracket siting
Frontal Perspective: The vertical midline scribe of the bracket is to be superimposed over the facial axis of the crown. The tie-wings sides are to be parallel to the facial axis of the clinical crown. The bracket is to be centered occlusogingivally on the facial axis of the clinical crown. Lateral Perspective: The mid-transverse planes of the crown and slot will be symbiotic when the base point of the bracket is sited on the crowns FA point.
Access Bevels for steel ligature cutters Generous Tie-Wing Undercuts for ease of ligation and space for multiple auxiliaries Contoured Slot Edges Mesial-Distal Stem 90 to Slot to align auxiliary rotation devices with archwire Compound-Contoured Base and Pad Horizontal and vertical base contours match the curvature characteristics of each tooth type for an optimal fit
Rounded Post for patient comfort (optional) 80-Gauge Micro-Etched Bondable Mesh Pad offers proven bond adhesion Color ID Dot for ease of bracket identification
Wider Pad on Lower 5s offers greater bond strength and a weld option
Instrument Groove for precise molar placement Smooth Hook for patient comfort
Pad width allows the molar to be bonded or welded Convertible Cap for ease of 2nd molar access
The instrument channel is wider at the center of the bracket to allow a carver instrument to finely adjust and control bracket positioning.
The de-ligation saddles allow for easy removal of elastic ligatures. The design is a scoop out of the bracket stem above and below the archwire slot which allows access for an explorer type instrument.
The stem of the bracket body is positioned 90 to the archwire slot which allows for a more aligned rotational force of an auxiliary wedge against the archwire.
Access bevels on each of the four tie-wings allow ease of removal of metal ligatures from any angle.
L7R
L6R
l5r l4r l3r l2R l1r l1l l2l l3l l4l l5l
L6L
L7L
Cuspid Hk
-7
+8
712-804HK
712-805HK
Standard
1st Bicuspid Hk
-7
+2
712-806HK
712-807HK
Standard
2nd Bicuspid Hk
-7
+2
712-808HK
712-809HK
Standard
Bracket images are not representative of actual size, or ratio to other brackets.
Cuspid Hk
-11
+3
712-812HK
712-813HK
Standard
1st Bicuspid Hk
-17
+2
712-814HK
712-815HK
Standard
2nd Bicuspid Hk
-22
+2
712-816HK
712-817HK
Standard
Bracket images are not representative of actual size, or ratio to other brackets.
Bracket images are not representative of actual size, or ratio to other brackets.
andrews 2 archwires
Optimal arches are essential for optimal occlusion. Andrews Archwires have the features needed to treat arches to optimal standards efficiently.
.014, .016 Nitanium Super Elastic Wires have flexibility for initial aligning and rotations .014, .016 stainless steel wires have a balance of flexibility and rigidity for initial aligning and leveling .016, .018 stainless steel wires have a balance of flexibility and rigidity for leveling, correcting arch shape, and for mesiodistal translation .018 x .025 Ortholoy-Blue (heat treatable) stainless steel wires are for inclining and fine tuning Flexibility: Arches can be effectively and efficiently treated to optimal standards by using the most appropriate Andrews Appliance prescription in combination with the most suitable Andrews Archwires in terms of flexibility. Shape: The Andrews Archwires are preformed to match the average shape of the 120 non-orthodontic normal study casts used in the Six Keys to Normal (Optimal) Occlusion study. Like any preformed archwire, its shape must be customized to each patients unique anatomy. Length: The overall length can usually be customized with one cut. Pre-Posted Archwire Option: For each arch, the small, medium, and large distances between the posts means one of the 3 will fit 90% of the normal patient population.*
7
andrews 2 archwires
Archwire
ortholoy-blue archwire
Andrews 2 Arch Form Single Pack 10/Pack
Arch Form Packaged .014 Upper .014 Lower .016 Upper .016 Lower .018 Upper .018 Lower
.017 x .025 Upper** .017 x .025 Lower** .018 x .025 Upper .018 x .025 Lower
112-146 112-147
112-172 112-173
Archwire
Archwire
Arch Form Packaged .016 Pre-Posted Upper 33 mm posted 37 mm posted 41 mm posted .016 Pre-Posted Lower 24 mm posted 28 mm posted 32 mm posted .018 Pre-Posted Upper 33 mm posted 37 mm posted 41 mm posted .018 Pre-Posted Lower 24 mm posted 28 mm posted 32 mm posted
Andrews Archwires are great for use with the Andrews Appliance.
Andrews2 Prescription
Part Number 0.022 Single Patient Kits/Introductory Kit without Molars U/L 5x5 Rx #5 Standard (Hks on 3s, 4s, 5s) U/L 5x5 Rx #5 Standard (HKs on 3s) Carousel 712-905 712-905HK Q-Packs U/L 5x5 Rx #5 Standard (Hks 3s, 4s, 5s) U/L 5x5 Rx #5 Standard (Hks 3s) 712-905Q 712-905HKQ
10
translation brackets
When teeth require mesial or distal bodily movement, translation brackets have significant advantages over standard brackets. Translation brackets include all of the qualities and features of standard brackets, plus a power arm and built-in counter-angulation and counter-rotation. Collectively, the width of the brackets, length of the power arms, and the counter-angulation direct forces close to or at the tooths center-of-resistance. This allows for effective bodily movement and the right amount of over correction (angulation and rotation) when using flexible archwires and sliding mechanics.
Power Arm for delivering force toward the tooths center of resistance
Translation Identification Dots make it easy to identify the specific translation bracket
Counter-Angulation adds counter-movements during translation and the right amount of over correction 2nd Pre-Molar Identifier
Counter-Rotation adds rotational control during translation and slightly over corrects Translation 1st Molar
11
Andrews2
The bracket sets found on this page and the following page are for both upper and lower arches, except where noted.
Arch Discrepancy category Inventory Arch quadrant treatment plan Percent discrepancy
2%
(+)9-14 mm
SPACED
3%
(+)5-8 mm
5%
(+)1-4 mm
2%
0 mm (Ext.)
CLASSIC
Non-extraction condition with premolar extractions. Translate posterior teeth mesially 4.5 to 7 mm per quadrant. Useful when opposing arch needs reciprocal resistance. (Rx #4)
30%
0 mm
12
30%
(-) 1-5 mm
Move posterior teeth distally 0.5 to 2.5 mm per quadrant. (Rx #5)
7%
(-) 6 mm
5%
(-) 7-8 mm
CROWDED
5%
(-) 9-10 mm
Extract 1st premolars. Translate canines distally 4.5 to 5 mm per quadrant. Translate posterior teeth mesially 2 to 2.5 mm per quadrant. (Rx #8) Extract 1st premolars. Translate canines distally 5.5 to 6 mm per quadrant. Translate posterior teeth mesially 1 to 1.5 mm per quadrant. (Rx #9)
4%
(-) 11-13 mm
4%
(-) 14 mm
Extract 1st premolars. Translate canines distally 7 mm per quadrant. (Rx #10)
3%
Extract upper 1st premolars only. Translate canines distally up to 7 mm per quadrant. Maxillary molars finish 7 mm mesial to Key 1. (Rx #11)
13
T4 T3 T2 T1
T4 T3 T2 T1
U7R
U6R
u5r u4r u3r u2R u1r u1l u2l u3l u4l u5l
U6L
U7L
Standard Brackets
L7R
L6R
l5r l4r l3r l2R l1r l1l l2l l3l l4l l5l
L6L
L7L
L7R T1 T2 T3
L6R
l5r
l4r
l3r T1 T2 T3
T1 T2 T3
l3l
l4l
l5l
L6L
L7L T1 T2 T3
14
Cuspid PA
-7
+11
3M
712-804T3
712-805T3
T3
2nd Bicuspid PA
-7
2D
712-808T2
712-809T2
T2
2nd Bicuspid PA
-7
-1
3D
712-808T3
712-809T3
T3
Bracket images are not representative of actual size, or ratio to other brackets.
15
1st Molar
-14
+3
10
2D
712-850T2
712-851T2
T2
1st Molar
-15
+2
10
3D
712-850T3
712-851T3
T3
1st Molar
-10
712-850T4
712-851T4
T4
2nd Molar
-14
+3
10
2D
712-852T2
712-853T2
T2
2nd Molar
-15
+2
10
3D
712-852T3
712-853T3
T3
2nd Molar
-10
712-852T4
712-853T4
T4
Bracket images are not representative of actual size, or ratio to other brackets.
16
Cuspid PA
-11
+6
3M
712-812T3
712-813T3
T3
2nd Bicuspid PA
-22
2D
712-816T2
712-817T2
T2
2nd Bicuspid PA
-22
-1
3D
712-816T3
712-817T3
T3
Part Number Tooth 1st Molar Inclination -30 Angulation +1 Counter Rotation 1D .022 L 712-854T1 .022 R 712-855T1 Note T1
1st Molar
-30
2D
712-854T2
712-855T2
T2
1st Molar
-30
-1
3D
712-854T3
712-855T3
T3
2nd Molar
-35
2D
712-856T2
712-857T2
T2
2nd Molar
-35
-1
3D
712-856T3
712-857T3
T3
Bracket images are not representative of actual size, or ratio to other brackets.
17
Part Number 0.022 Single Patient Kits/Introductory Kit without Molars U/L 5x5 Rx #1 Spaced 9-14 mm U/L 5x5 Rx #2 Spaced 5-8 mm U/L 5x5 Rx #3 Spaced 1-4 mm U/L 5x5 Rx #4 Extraction-4 Classic U/L 5x5 Rx #6 Extraction-5 6 mm 2nd Pre-Molars U/L 5x5 Rx #7 Extraction 7-8 mm U/L 5x5 Rx #8 Extraction 9-10 mm U/L 5x5 Rx #9 Extraction 11-13 mm U/L 5x5 Rx #10 Extraction 14 mm U/L 5x5 Rx #11 Extraction 14 mm Extraction U4 U/L 5x5 T2 Kit (T2s on 3s, 4s, 5s) Carousel 712-901 712-902 712-903 712-904 712-906 712-907 712-908 712-909 712-910 712-911 712-90T2 Q-Packs U/L 5x5 Rx #1 Spaced 9-14 mm U/L 5x5 Rx #2 Spaced 5-8 mm U/L 5x5 Rx #3 Spaced 1-4 mm U/L 5x5 Rx #4 Extraction-4 Classic U/L 5x5 Rx #6 Extraction-5 6 mm 2 Pre-Molars
nd
712-922Q 712-912Q 712-913Q 712-914Q 712-916Q 712-917Q 712-918Q 712-919Q 712-920Q 712-921Q 712-91T2Q Andrews 2 Bracket Kit 712-930 712-930HK 712-000 Andrews Books
712-901Q 712-902Q 712-903Q 712-904Q 712-906Q 712-907Q 712-908Q 712-909Q 712-910Q 712-911Q 712-90T2Q Andrews 2 Bracket Kit 712-900 712-900HK
U/L 6x6 Rx #7 Extraction 7-8 mm U/L 6x6 Rx #8 Extraction 9-10 mm U/L 6x6 Rx #9 Extraction 11-13 mm U/L 6x6 Rx #10 Extraction 14 mm U/L 6x7 Rx #11 Extraction 14 mm Extraction U4 Only U/L 7x7 T2 Q-PK Kit (T2s on 3s, 4s, 5s, 6s, 7s) Intro Kit with Molars U/L 6x6 30 Case Introductory Kit * (Hks 3) U/L 6x6 30 Case Introductory Kit * (Hks 3,4,5) Andrews 2 Bracket Organizer Kit (empty)
U/L 5x5 Rx #7 Extraction 7-8 mm U/L 5x5 Rx #8 Extraction 9-10 mm U/L 5x5 Rx #9 Extraction 11-13 mm U/L 5x5 Rx #10 Extraction 14 mm U/L 5x5 Rx #11 Extraction 14 mm Extraction U4 Only U/L 5x5 T2 Q-PK Kit (T2s on 3s, 4s, 5s) Intro Kit without Molars U/L 5x5 30 Case Introductory Kit * (Hks 3) U/L 5x5 30 Case Introductory Kit * (Hks 3,4,5)
631-712X
18
Dr. Will Andrews completed orthodontic training at the University of California at San Francisco (UCSF) in 1992. He is a Diplomate of the American Board of Orthodontics, a member of the Edward H. Angle Society of Orthodontists, an assistant clinical professor at UCSF, and an adjunct assistant professor at West Virginia University. Dr. Andrews has lectured worldwide, published articles about the Six Elements Orthodontic Philosophy, and maintains a private practice limited to orthodontics in San Diego, CA.
Straight Wire
19
Andrews Foundation
For information on courses about the Andrews2 Appliance, contact the Andrews Foundation: In the U.S. 800.799.8952 | Outside the U.S. +(1) 619 224 0866 Website: AndrewsFoundation.org
For more information on Ortho Organizers products and education offerings, please contact us: In the U.S. 888.851.0533 I Outside the U.S. +(1) 760 448 8600 I Canada: CERUM 800.661.9567 To fax an order: 800.888.7244 I To email an order: USASales@OrthoOrganizers.com Like us on Facebook: facebook.com/orthoorganizersonfb
ORTHOORGANIZERS.COM
2013 Ortho Organizers, Inc. All rights reserved. PN 999-255 03/13. Trademarks are the property of their respective owners. Patent pending.