Gloss is measured on a glossmeter. This instrument has an incandescent light source and a photosensitive receptor which responds to visible light. Light shines onto the sample at a specified angle. Some of this light is reflected into the photosensitive receptor. The fraction of the original light which is reflected is the gloss of the sample. Gloss is an important merchandising factor and this test makes it possible to specify and control this surface characteristic so that the desired effect will be assured. Haze - ASTM-D-1003 The haze of transparent packaging materials is measured on a special hazemeter which has an incandescent light source and geometrically arranged photocells that measure the transmitted and scattered light. The sample is placed between the light source and the photocells. The amount of light transmitted by the sample, the light scattered by the sample and the instrument and the total incident light are measured. From these values the percentage of transmitted light which is scattered can be calculated. The hazemeter measures these variables and interrelates them so that the percentage of scattered light can be read on the meter. this test is important to products or in uses where true color and high visibility are required. Transmittance - ASTM-D-1003 The percent of light transmission on translucent materials is measured on the same instrument as haze. Using its incandescent light source and geometrically arranged photocells which ratio the amount of light transmitted through the sample versus the amount transmitted with no sample present. Transmittance, Opacity and Optical Density are related mathematically as: Opacity = 1 / Transmittance Optical Density = Common Logarithm (Opacity)
Tappi Opacity - T-425 Tappi Opacity is a reflectance type of Opacity measurement. It is a contrast ratio obtained by testing the samples reflectance when backed by a black material versus the reflectance when the film is backed by a white material. The incandescent light source and photocell detector are on the same side of the sample while the background is placed behind the sample. Tappi Opacity = Light reflected when sample backed by black background / Light reflected when sample backed by white background Water-Vapor Transmission - ASTM-F372 The water vapor transmission rate (WVTR) through flexible barrier films is measured using an infrared diffusometer. The diffusometer establishes a condition of 90% relative humidity at 100F on one side of a film by means of a heated saturated salt solution and a condition of 0% relative humidity at 100F on the other side using a stream of warm dry air. When the source of dry air is turned off, moisture vapor permeating the film from the moist side accumulates on the dry side. The rate at which this moisture build up takes place is sensed by an infrared detector and recorded as WVTR. This test is extremely important since it gives a "baseline" value for comparing films in terms of moisture barrier. However, it should be pointed out that WVTR is normally measured on flat sheets and does not include end use package variables such as heat seals, folds, and creases. Tear-ASTM-D-1922 A tear tester has a stationary clamp and a movable clamp on a pendulum, means for holding this pendulum in a raised position, then quickly releasing it, and a scale that registers the arc through which the released pendulum swings. Samples of paper or film are clamped into the tester and nicked to start the tear; then the pendulum clamp is released. This tears the sample and the scale registers the arc. As the arc is proportional to the tear strength of the sample, calibration of the arc gives the tear strength. Tear strength is reported in grams. It is the force necessary to continue tearing a sample after a nick has been made. This test is very important for all films as well as for paper. High tear values may be needed for machine operations or for package strength. However, low tear values are necessary and useful for easy opening of some package types.
Tensile and Elongation - ASTM-D-882 The testing machine of clamps to hold the sample, some means of gradually increasing the load on the specimen until it breaks and indicators which show the load and the amount of elongation. To perform the test, measured, gauged specimens are clamped into the testing machine and stretched until they break. Tensile strength is usually reported in pounds per inch of width necessary to pull the paper apart. For films, the usual units are pounds per square inch of original cross-sectional area. Tensile strength is quite literally the amount of force necessary to pull a material apart. The elongation is the amount a material will stretch before breaking. Tensile strength is a most important value for materials used in applications such as heavy-duty bags. A large value for elongation is an index of toughness, since it indicates a material will absorb a large amount of energy before breaking. Gas Transmission Test specimens are clamped in the 100 cm2 diffusion cell. Both sides of the cell are initially purged with an oxygenfree carrier gas to remove residual oxygen from the system and de-sorb oxygen from the sample. When a stable zero reading has been established, oxygen is introduced into the upper half of the diffusion chamber. The carrier gas continues to flow through the lower half and into the coulometric oxygen detector. After a short interval, the first molecules of oxygen diffusing through the barrier are conveyed by the carrier gas to the detector. As displayed by the graphic recorder, the detector current rises, finally leveling off at a value representative of the equilibrium transmission rate of oxygen through the barrier. It should be noted that this equilibrium transmission rate is independent of the flow rate of the carrier gas. Impact Strength - ASTM-D-3420 The pendulum impact tester can be used to measure impact strength of papers, boards and films. An impacting head on the end of a pendulum is swung through an arc into and through sample. Tester has a means of measuring difference between potential energy of pendulum at maximum height in free swing and potential energy of the pendulum after rupture of sample. This difference in energy is defined as impact strength and is reported in units of kilogram-centimeters. It is useful in predicting resistance of a material to breakage from dropping or other quick blows.
A test similar in scope, method and significance is the dart drop test (ASTM-D-1709). Weighted dart is dropped from standard height onto taut sample. Significance and purpose are the same as in the pendulum test. Dart unit is weight of dart in grams that breaks sample 50% of the time. These tests give an index of material's dynamic strength and approximate what will occur when package is dropped.
***************************************************************************************** *
SEAL = HEAT + TIME + PRESSURE The sum total of these three variables should remain constant in order to effect consistent seals. For example, if dwell time is reduced, then heat or pressure may be needed to be increased to compensate. The effort to regulate heat is not as straightforward as simply setting the temperature on a controller to the suggested sealing temperature of a packaging material. Machine speeds effect the temperature of the crimper or sealing jaw face, since heat is constantly being drawn off the face by the packaging material. The heat must also be sufficient to penetrate from the face of the crimper or jaw through the film or lamination to the sealant layer, and not so high that it damages the film or lamination.
The more time available for contact between the crimpers and the packaging materials (referred to as dwell time), the more heat can penetrate through to the sealant layer. As production speeds are increased, sealant layer quality and/or quantity may need to be enhanced. Crimpers and sealing jaws can be manufactured from special materials that are especially good at transferring heat. Easy Seal Crimpers utilize a special, durable bronze alloy sealing face, and sealing jaws can also be manufactured with copper bodies and durable Hastelloy sealing faces. Col Seal films remove both heat and time as variables, since all that is required to make a seal is pressure.
Pressure
The variability of pressure can be made constant through refinements in crimper or sealing jaw setup and design. Inadequate or uneven sealing pressure can cause end seal leaks, especially at the intersection of two and four layers of film in areas such as the fin seal, wrinkles or gussets. Sometimes additional heat or dwell time can help sealant to flow into and plug leaks in these areas, but these solutions may not be practical. Attempts to improve seals by increasing sealing pressure can cause the crimpers/jaws to split or cut the package. On all machines the serrations need to be aligned properly. On horizontal wrappers the crimper clearance and spring pressure need to be set properly, and backlash (independent movement of the upper and lower shafts) needs to be controlled. It can take a great deal of skill and finesse to create enough pressure to seal without having excess pressure split or cut the packaging material. If no amount of adjusting allows you to achieve adequate results, then a change in the design of the crimpers or sealing jaws is necessary. Design changes can entail an upgrade to Easy Seal Crimpers and/or a change in the serration pattern. Either way, our goal is to provide even sealing pressure across varying layers of film in the end seal area. It is rare to see crimpers and jaws on horizontal wrappers or vertical baggers with smooth faces; they almost all have some type of serration pattern. As the packaging material is stretched over the serration pattern extra sealing pressure is exerted. The serrations also cause a "shearing" action, where sealant layers from each side are forcibly mixed together, thus creating a stronger bond. The correct geometry and precision of the serration profile are critical for achieving even pressure. In order to recommend the best serration design we need to know about the variables specific to your situation, such as film thickness and stiffness, if there are wrinkles or gussets, machine speeds and conditions, etc. The best way to start this process is to provide us with sample packages for evaluation.
Setup
Design
Serration Patterns
The direction of the serrations is also important. Horizontal patterns are usually best at sealing off leaks, however
in some cases diagonal or vertical serrations are the best choice. One study found that a switch from vertical to horizontal serrations increased shelf life by over 40%. Easy Seal On horizontal wrappers Quick Change Inserts allow for precise, accurate setups that can be consistently repeated, so the variability of crimper setup is significantly reduced. In addition, the flexible faces accommodate extra film layers and provide even sealing pressure across the sealing face. Easy Seal Crimpers, couples with the proper serration profile, are the best tools for creating the even pressure necessary for dramatically improved seals.
***************************************************************************************** *
Gauge
Definition Relevance and non-relevance to performance What affects film thickness Test principles Related Terminology
Definition
Gauge, or thickness, is a basic descriptive film property. Values are expressed as mils in the US standard and microns in the metric (or SI) system. The word gauge has two other meanings in the film industry that should be mentioned, but are not the subject of this discussion. 1. "Gauge" is used as a unit of measure equal to a hundredth of a mil. For example, "70 gauge" refers to 70 hundredths of a mil, or .70 mil thickness. 2. "Gauge" can also refer to the general profile of a roll of film. For example, "that roll has bad gauge" means that the film is not flat across the width of the roll. This poor gauge profile manifests itself as hard and soft areas and permanent stretch lanes, which can cause processing problems.
back to top
There are two circumstances when it is important to measure thickness in the laboratory. 1. When measuring certain film properties (tensiles, WVTR and OTR), the gauge of the sample is always measured and noted. 2. Unlike solid films, cavitated OPPalyte films can have various thicknesses even when yield is constant. So, the optical gauge of these films is measured in the Quality Control (QC) laboratory, and the process is adjusted if the value is outside an acceptable range.
back to top
The average film thickness of cavitated white opaque films (OPPalyte) is a function of yield and the degree of cavitation. (The more cavitation, the thicker the film.) With these films, yield is controlled with extruder screw speed, and cavitation is controlled by optically measuring gauge in the laboratory and adjusting the appropriate process parameters, as necessary. For coated films, primer and top coats are applied to one or both sides of a base film with a separate coating line. Coating weights are precisely controlled, and the added thickness is easily estimated. Coated film yields are regularly measured by the QC laboratory.
back to top
Test principles
ExxonMobil has two procedures for measuring or calculating thickness, each using different commercially available instruments. 1. #440 (Micrometer-measured gauge) This procedure describes the appropriate use of a mechanical micrometer to determine the gauge of a film sample being tested for tensiles or barrier. (These tests require that gauge is tested and noted.) It is important that the specimen be free of creases, visible defects, and dirt. The micrometer head and anvil must be clean. Mechanical micrometers should not be used on cavitated white opaque films because they can easily crush the core which will lead to a faulty, thinner gauge measurement. (See alternate procedure below. ) 2. #598 (Optical gauge) Shawnee developed a procedure for the optical measurement of gauge. Since Shawnee and Macedon produce cavitated white opaque films, and traditional micrometers can be inaccurate with these films, these plants use this non-contact optical procedure that utilizes laser technology. It is important to select a measurement instrument that is designed for accuracy in the desired thickness range. For more information from the instrument suppliers, contact Mahr Federal Inc., Providence, RI, www.fedgage.com about mechanical micrometers or Beta LaserMike, Dayton, OH, www.betalasermike.com about non-contacting measurement devices.
back to top
Related terminology
Mil Mil is a thousandth of an inch. A 0.70 mil film is 0.0007 inches thick.
Micron
Micron () is 10-6 meters and 25.4 mils. A 1 mil film is approximately 25 thick.
***************************************************************************************** *
Definition Relevance and non-relevance to performance What affects film yield and how well it is controlled Test principles Related Terminology
Definition
Yield is the measure of a film's coverage per unit weight. Values are expressed as in 2/1b in US standard and m2/kg in metric (or SI) units. Unit weight is the reciprocal of yield and is presented in units of lb/ream or g/m 2. The film industry tends to use yield values, while the paper industry favors unit weight. Our discussion here will focus on yield, but the principles also hold true for unit weight.
back to top
back to top
Test principles
To measure yield, a precise area of film is cut and then weighed on an analytical balance. The area is divided by the weight, expressed as in2/lbor m2/kg,and reported to three significant digits. The recommended minimum specimen size is 300 in2 (1940 cm2) and should be obtained by folding a single layer of film multiple times in the machine and transverse directions. Example: Film is folded two times in the machine direction and two times in the transverse direction. Therefore, 16 layers of film will be cut at once. The folded film is precision cut with a 5 inch (.127 m) diameter round die, and the measured weight is 3.496 grams. Based on this example, the following equations demonstrate the yield and unit weight calculations in US standard and metric units. Total specimen area = Weight of specimen (2.5)2 in2 16 453.59 g/lb 3.496 g
Yield (in2/lb) =
40,761 in2/lb
It is reported as 40,800 in2/lb. Yield (m2/kg) = Total specimen area = Weight of specimen (.0635)2 m2 16 1000 g/kg 3.496 g 57.976 m2/kg
It is reported as 58 m2/kg. Unit weight (lb/ream) = 1 = Yield 1 lb 40,761 in2 432,000 in2 ream 10.6 lb/ream
= 10.598 ~
1 = Yield
1 kg 57.976 m2
1,000
g
= 17.249 ~
kg
10.3 g/m2
CAUTION:
Although yield is related to thickness, it is inaccurate to use a micrometer to assess yield. Micrometers lack the necessary accuracy and precision, and they only measure thickness at a small point, whereas the previously described method directlymeasures average yield over a large area. Also, thickness cannot be converted to yield without knowing the exact density of the film.
back to top
Related terminology
Basis weight Basis weight is a common paper industry term for unit weight, or weight per unit area. Units are lb/ream. "Ten pounds of poly" means 10 lb/ream, which equals 43,200 in2/lb (because a ream equals 432,000 in2) or .70 mils of LDPE (at a specific gravity of .92).
MSI
MSI stands for thousand square inches. Yield can be converted from in2/lb to MSI/lb by dividing by 1000. Film pricing is commonly quoted in $/lb or $/MSI, and yield can be used to convert from one set of units to the other.
Ream
Ream is a paper industry term equivalent to a coverage area of 3000 ft2 or 432,000 in2.
***************************************************************************************** *
Tensiles
Definition Relevance to performance What affects a film's tensile properties Test principles Related Terminology
Definition
Tensile testers, such as an Instron, measure a film's resistance to being pulled apart at a constant rate of speed. ExxonMobil uses this test to report three significant properties. 1. Ultimate tensile strength is the maximum force of resistance divided by the film's initial crosssectional area. Values are expressed in Ibf/in2 (psi) in US standard units and N/mm2 in metric (SI) units.
2. Tensile modulus is a stress-strain ratio calculated from any point on the initial straight line portion of the load-extension curve. It is measured just as the material begins to experience tension. This value is an indicator of the film's stiffness and resistance to elongation in use. The units are Ibf/in2 (psi) and N/mm2. 3. Elongation is the percent change in length of the material under stress from start to break. Elongation "at yield" is measured from start to yield point. The units are %.
back to top
Relevance to performance
Tensile properties are an important and common way to compare physical properties of diverse materials, from steel to plastic. In the narrower realm of flexible films, these tests provide measurement of attributes we can see and feel: strength, stiffness, and resistance to stretching. Some materials are stronger than others, and some, like polypropylene, can dramatically improve their strength through orientation as shown in Table 3. Tensile Property Cellophane Ultimate strength (kpsi) Elongation (%) 7-18 10-50 Oriented PET 20-40 60-165 Blown LDPE 1.5-4 100-700 OPP 15-40 35-475
Table 3: Typical tensile values for common films* *Although there is a wide range of property values for each material (because of the many choices available in resin formula, processing, and direction of testing), Table 3 shows the characteristic performance range for each type of film. The effect of orientation is reflected in the property differences between cast PP (unoriented polypropylene) and OPP (biaxially oriented polypropylene). Within the arena of OPP films, tensiles are generally not critical and rarely require discussion and specification between supplier and customer. This is so because oriented polypropylenes provide a dependable range of tensile values. Other properties are usually more important to successful performance. There are two notable exceptions worthy of explanation. 1. Orientation method: blown or tentered The orientation method causes characteristic differences in tensile properties. Blown films are "balanced," having similar strength and elongation in the machine and transverse film directions. Tentered films (as are all ExxonMobil films) have higher strength and lower elongation in the transverse direction than in the machine direction. Most OPP manufacturers produce tenteroriented films, which work well in many diverse applications. 2. Modulus and web tension Modulus, because it is a measure of strength characteristics in the film's elastic region, provides valuable insight into stiffness and how extensible the film is under normal use tensions. When comparing two films of identical thickness, the one with a higher modulus will be stiffer and stretch less under the same tension force. High temperature modulus testing and empirical trials on converting equipment have yielded an industry rule of thumb: OPP web tensions should be controlled to .50lb f per inch of film width, or less, for good registration and no permanent deformation (elongation, neck-in, gauge bands). From a filmmaker's perspective, the lowest controllable web tension is best. Thinner films and higher converting temperatures make this more critical.
NOTE:
back to top
Test principles
Each end of a film specimen, of specific width and measured thickness, is held by a clamp or grip. One grip is stationary, while the other is pulled away from the first at a pre-selected velocity. The machine continuously measures the changing distance between the grips and the force exerted on them as they pull the film apart. The test is completed when the sample breaks. Today, most machines run automatically after the operator selects settings, loads the specimen, and initiates the test. Most are also equipped with microprocessors that perform the calculations and automatically display all the resulting values. But, the test concepts are best understood by studying loadextension curves like the ones shown in Graph 1. These are actual machine direction (MD) and transverse direction (TD) load-extension curves for a typical, tenter-oriented, 75 gauge OPP. In Graph 1, load is plotted as a function of extension, and the tensile tester software calculates the following properties that are noted in Table 4.
Table 4: Tensile values from Graph 1 Table 4 values are software-generated results based on the following equations. Ultimate Tensile Strength (psi) = Max Load (lbf) Max Load (lbf) = Initial cross-sectional area 1 in x .00075 in
Modulus (psi) = At any point on the elastic region tangent line (Stress Strain) = Load (lbf) Extension (in) = Load (lbf) Extension (in)
.00075 in2
2 in
Test conditions like pull speed, initial grip separation, full-scale load, and sample width will affect the results. ASTM test procedure D 882 describes a protocol for making choices about these settings. For simplicity and accuracy in comparing values, ExxonMobil uses highly automated tensile testers and has standardized to a particular set-up. These conditions are summarized in Table 5. Test Condition Machine Direction (MD) Ultimate Strength Crosshead speed (in/min), i.e. pull velocity Grip separation (in) Sample width (in) 20 2 1 Modulus .5 2 1 Elongation 20 2 1 Transverse Direction (TD) Ultimate Strength 20 2 1 Modulus .5 2 1
Elongation
20 2 1
Table 5: ExxonMobile standard conditions for tensile testing ExxonMobil has two test procedures for tensile testing: one for use with Instron equipment (#506) and one for use with Sintech machines (#510). With both tests, the specimen is subjected to identical evaluation conditions. The tensile properties for all coated and metallized films are measured on base sheet prior to coating or metallization.
NOTE:
Tensile properties can change with small changes in temperature; so it is important to conduct tests in a controlled environment. Standard laboratory temperature is 72F (22C) 2F (1C).
back to top
Related terminology
Young's modulus Modulus of elasticity Tangent modulus Modulus of elasticity Tangent modulus These are all terms synonymous with tensile modulus, a material property defined as the stress-strain ratio of the initial portion of a load-extension curve. A higher modulus value suggests that this material will be stiffer and have more resistance to elongation in use (when comparing films of the same thickness). Standard units are Ibf/in2 (psi) and N/mm2.
Secant modulus
Secant modulus is an alternate approximation of modulus and better predictor of performance, when there is no straight line portion on the load-elongation curve. It is the stress-strain ratio at the point on the curve that corresponds to a specific designated extension. For example, a 1% secant modulus would be the material's stress/strain, in psi or N/mm 2, at the point of extension that is 1% of initial sample length. This can be a useful value, because with no early straight line portion of the curve, the traditional tangent calculation will render a result that predicts the material to be stiffer and less extensible than it really is.
Strain
Strain is the ratio of the change in length of the sample (also called extension) to the original length of the sample. Strain is a unitless value and is converted to % elongation by multiplying by 100.
Stress
Stress is load (Ibf or N) divided by the original cross-sectional area (in2 or mm2) of the specimen. By definition, this value is normalized for gauge.
Yield point
Yield point is the point during the test cycle when the specimen continues to elongate, but there is no increase in load. OPP films typically do not have a clear yield point.
***************************************************************************************** *
Dimensional Stability
Definition
Dimensional stability is the change in length of an unrestrained film sample subjected to a specific elevated temperature. ExxonMobil typically measures this property at 275F (135C). Machine direction (MD) and transverse direction (TD) values are evaluated and reported separately. Units are reported as % change from the original dimension.
back to top
Relevance to performance
In general, materials expand when subjected to elevated temperatures. Oriented films, on the other hand, are likely to shrink because the polymer has "memory" and tries to return to its unoriented dimensions. Dimensional stability values for different films (measured at the same temperature) provide a relative comparison of how much film distortion will occur in heated processes, like oven drying or package sealing. Acceptable temperatures for processing a film vary and are dependent on the film properties, the type of process (contact with heated air or heated metal), the dwell time, and whether the film is restrained or not. OPP films are typically designed for minimal shrinkage. Most ExxonMobil OPP films can be used in very high-speed, low-dwell heat seal applications with actual crimp jaw temperatures of up to approximately 355F (180C) without causing unsightly seal distortion. However, longer dwell exposures (> second) require that temperatures do not exceed about 300F (149C) to prevent severe shrinkage. OPP is commonly used at temperatures between 220F and 300F (104.5C to 149C), where it can have a slight dimensional change. Test values at 275F (135C) for tenter-oriented OPP are typically -2% to -8% in both the machine and transverse directions. Some films are designed to shrink in a predictable way, like the new, developmental ExxonMobil film Bicor TYTE. TYTE provides a crisp, tight overwrap for products like CD jewel cases, video tapes, and food or pharmaceutical boxes. Its dimensional stability values are -9% in the MD and -14% in the TD.
back to top
Test principles
ASTM D 1204 and ExxonMobil procedure #438 follow the same principles, but differ in some specific protocols. Both tests involve placing a film sample of known original dimensions into a temperaturecontrolled convection oven for a certain period of time and measuring the length of the sample after conditioning. Results are reported as % change. Negative numbers indicate shrinkage, while positive numbers indicate expansion. Pertinent details of the two procedures are summarized in Table 6. Test Procedure Test Conditions Specimen Oven Size Temperature Convection oven 1" x 7" cut controlled to ExxonMobil in MD, and target, #438 one in TD typically 275F (135C) ASTM D 1204 Convection oven controlled to target 1C Time in Oven Pre/Post Precision Conditioning
Reporting
7 min
None
10" x 10"
Table 6: Comparison of dimensional stability test conditions between ExxonMobil and ASTM procedures
***************************************************************************************** *
Haze
Definition Relevance to performance What determines the haze level of a clear film Test principles Related Terminology
Definition
Haze is the scattering of light by a film that results in a cloudy appearance or poorer clarity of objects when viewed through the film. More technically, haze is the percentage of light transmitted through a film that is deflected more than 2.5 (degrees) from the direction of the incoming beam. This property is used to describe transparent and translucent films, not opaque films.
back to top
Relevance to performance
Film clarity is a highly desirable feature for most clear packaging and label applications. It tends to symbolize quality and contributes to the positive visual display of the product. Compared to other flexible plastic films, clear OPP has one of the lowest haze values, generally less than 3%.
back to top
Test principles
As represented in Figure 1, a unidirectional light beam is directed onto the film specimen. After it enters an integrating sphere, a photo detector measures the total light transmitted by the film and the amount of transmitted light that is scattered more than 2.5. Haze is the percentage of total transmitted light that is scattered by more than 2.5.
Figure 1: Haze measurement Commercial hazemeters are typically used for this testing, but ASTM D 1003 also allows the use of a spectrophotometer, provided it meets the procedure requirements. ExxonMobii uses the SKY-Gardner XL211 Haze-gard and Haze-gard plus hazemeters consistent with ASTM guidelines. The hazemeter may also be set up to measure and display light transmission.
back to top
Related terminology
Light transmission
Light transmission is the percentage of incident light that passes through a film, which is represented by the following equation. T Light Transmission (%) = T x 100 i
t
Translucent
Translucent describes material that transmits light, but also diffuses it, so that objects cannot be seen clearly.
***************************************************************************************** *
Coefficient of Friction
Definition Relevance to application performance How COF is modified in films Test principles Related terminology
Definition
Coefficient of friction (COF) is a unitless number that represents the resistance to sliding of two surfaces in contact with each other. These values should be between 0 and 1. Higher values indicate more resistance to sliding. Static COF values are measured as two surfaces just begin to move against each other and kinetic values are measured after constant motion is achieved. ExxonMobil reports kinetic COF values.
back to top
On VFFS, film enters forming collar Low outside friction, film-to-metal Prevents film squealing, inconsistent as horizontal flat web and is film feeding and inconsistent bag transformed into a vertical tube. lengths. Filled packages are being stuffed into corrugated shipping boxes. Low outside friction, film-to-film Allows packs to slide against each other and settle for easy carton closing.
On friction belt drive VFFS, servo- Moderate outside friction, low driven belts push and move film inside friction against inside tube.
Belts must "grab" outside surface to move film, while inside surface must slide over stationary tube to prevent jams.
Filled packages slide down a chute Low outside friction, film-to-chute Keeps products moving. to reach downstream packaging operations. Filled packages are carried on an inclined conveyor belt. Moderate or high outside friction, film-to-conveyor Keeps product from losing placement or falling off conveyor.
Table 7: Examples of various applications requiring different fictional properties You can see from the table above, that each different situation has very different stresses and expectations. Sometimes the film is forced to change shape, or slide across a metal surface, or "grab" against a drive belt. It's impossible for a laboratory measured film-to-film COF to predict performance in all these applications. Instead, film-to-film COF measurements are used for process control to ensure the consistent production of a film that has been proven during the product development process to work in its target applications.
For example, a key to good performance on a VFFS machine is the film's outside frictional properties that allow it to travel over the forming collar without squealing or inconsistent feeding. ExxonMobil produces films with high-tech, non-migratory slip systems that have higher COFs than older fatty amide-type films, but run flawlessly on these machines. Traditional thinking might claim that "the COF is too high" with these films, but this is clearly not true. Then standard COF laboratory test is frequently not a good comparison test for predicting performance.
CAUTION:
Do not draw conclusions about performance from small differences (differences of. 10 or less) in the laboratory film-to-film COF values of different film products. Instead, two different types of films should be compared by conducting trials in the desired application.
back to top
5. Fatty amide can deposit and accumulate on rollers and packaging machine surfaces. 6. The additive can interfere with print quality. Most ExxonMobil films do not incorporate migratory fatty amide slip systems. Instead, the COF of these uncoated films is optimized with proprietary resin and additive formulations, which provide consistent, low friction performance. We refer to these as "non-migratory" slip systems. They eliminate the problems associated with using fatty amides to achieve a lower COF. The previous discussion refers to how COF is modified in uncoated coex and slip films. Remember, ExxonMobil acrylic-coated surfaces have inherently low and stable COF and provide excellent machine performance.
NOTE:
back to top
Test principles
COF is a simple ratio equal to the force required to slide one surface over another, divided by the force perpendicular to the contacting surfaces. COF = Force to cause sliding of film surfaces (gf) ; a unitless coefficient sled weight (gf)
ExxonMobil uses commercially available test equipment to measure film-to-film COF at conditions defined by ASTM D 1894. Table 8 provides a summary comparison. Test Procedure Test Conditions Sled Sled Measurement Contacting Contact Pull Weight Apparatus Surfaces Dimensions Method (g) (in) ExxonMobil TMI #32-06 #430 ASTM D 1894 Not specified Film to film Not specified 200 200 2.5 x 2.5 2.5 x 2.5 Moving sled Moving sled or plane
Pull Speed (in/min)
6 6
Table 8: Comparison of COF test conditions between ExxonMobil and ASTM procedures The TMI tester provides a digital display of static and kinetic COF. Static COF is a higher value and is related to the force to get movement started. Kinetic COF is the number typically displayed in data sheets and is an average value after Y2inch of travel. COF values generated in different laboratories or on different testers show wide variation when measuring the same film. For example, ASTM looked at the precision of COF data between laboratories and found standard deviations (depending on film type) between .02 and .12. Therefore, it does not make sense to assume that there is necessarily a real difference between, for example, a .28 measured by one company and a .34 measured by another.
back to top
Related Terminology
Fatty amide
Fatty amide is a very common migratory slip additive for plastic films. Fatty amides are greasy organic compounds such as stearamide, erucamide, behenamide and oleamide. They are compounded into resin and bloom to the surface after the film is produced.
Kinetic COF
Kinetic COF is the coefficient of friction value measured after surfaces are in motion at a constant speed.
Machinability
Machinability, also known as machine performance, is the ability of a film to travel and track well through a packaging machine. Different machines favor different film properties. Therefore, a film may demonstrate good machinability on one piece of equipment and not on another.
Non-migratory slip system Non-migratory slip system refers to newer technology that reduces the COF of films without the problems associated with fatty amides. ExxonMobil has been a leader in this area by engineering films with non-migratory additives and modified surfaces. These films have stable COFs and excellent converting and packaging machine performance.
Slip Slip is the opposite of friction. "High slip" denotes low COF and low slip denotes a high COF. A "slip film" is a non-sealable film that is specifically formulated using additives or surface modification for reduced surface friction. "Slip additive" usually refers to fatty amide. Static COF Static COF is the coefficient of friction value measured as two surfaces just begin to move against each other.
***************************************************************************************** *
Gloss
Definition
Gloss is a measurement of the relative luster or shininess of a film surface. ExxonMobil uses 45-degree gloss, where the incident light beam strikes the film surface at a 45 degree angle from the perpendicular. A sensor measures the amount of light reflected by the film at a mirror image angle. The gloss value is the ratio of this reflected light to incident light and is reported in gloss units. Theoretically, the range of the gloss scale is 0 to 100.
back to top
Test principles
ExxonMobil uses commercially available glossmeters to measure 45-deg gloss consistent with ASTM procedure D 2457. The simplified diagram in Figure 2 graphically summarizes the test.
WVTR
Definition Relevance to package performance What affects the WVTR of OPP films Test principles Related Terminology
Definition
WVTR (water vapor transmission rate) is the steady state rate at which water vapor permeates through a film at specified conditions of temperature and relative humidity. Values are expressed in g/100 in 2/24 hr in US standard units and g/m2/24 hr in metric (or SI) units. Test conditions vary, but ExxonMobil has
standardized to 100F (37.8C) and 90% RH, which is the most common set of conditions reported in North America.
back to top
WVTR @ 100F (38C), 90% RH for 1 mil film (g/100 in2/24 hr) 0.25 - 0.40 0.3 - 0.5 0.6 - 0.7 1.0 - 1.3 1.0 - 1.5 1.4 - 8.0 7 - 10 10 - 13 (g/m2/24 hr) 3.9 - 6.2 4.7 - 7.8 9.3 - 11 16-20 16 - 23 22 - 124 109 - 155 155 - 202
CAUTION:
In order for film moisture barrier to contribute its full product protection value, package seal integrity must be satisfactory. Poor quality seals can negate a film's good barrier by allowing vapor transmission through channel leakers and imperfections.
Within the arena of OPP films, tensiles are generally not critical and rarely require discussion and specification between supplier and customer. This is so because oriented polypropylenes provide a dependable range of tensile values. Other properties are usually more important to successful performance. There are two notable exceptions worthy of explanation. 1. Orientation method: blown or tentered The orientation method causes characteristic differences in tensile properties. Blown films are "balanced," having similar strength and elongation in the machine and transverse film directions. Tentered films (as are all ExxonMobil films) have higher strength and lower elongation in the transverse direction than in the machine direction. Most OPP manufacturers produce tenteroriented films, which work well in many diverse applications.
2. Modulus and web tension Modulus, because it is a measure of strength characteristics in the film's elastic region, provides valuable insight into stiffness and how extensible the film is under normal use tensions. When comparing two films of identical thickness, the one with a higher modulus will be stiffer and stretch less under the same tension force. High temperature modulus testing and empirical trials on converting equipment have yielded an industry rule of thumb: OPP web tensions should be controlled to .50lb f per inch of film width, or less, for good registration and no permanent deformation (elongation, neck-in, gauge bands). From a filmmaker's perspective, the lowest controllable web tension is best. Thinner films and higher converting temperatures make this more critical.
NOTE:
back to top
Graph 2: Plain OPP WVTR as a function of thickness The inherently good moisture barrier of OPP can be further enhanced by additives, coatings, or metallization. ExxonMobil produces high barrier PVdC-coated and metallized films that dramatically improve the WVTR of OPP and Hicor films. The values for four of these products, HBS-2, MET-HB, Hicor OHD, and Hicor BIHD-M, are plotted in Graph 2.
back to top
Test principles
ExxonMobil uses MOCON Permatran W instruments for measuring WVTR. The instrument design and the way we operate the instrument is consistent with ASTM F 1249. ExxonMobil standardizes its reporting to test conditions of 100F (38C) and 90% RH. Conceptually, a test cell looks like Figure 3. Dry nitrogen gas is swept through a chamber where the test film acts as the membrane separating this dry gas stream from a "wet" nitrogen stream on the other side. The partial pressure difference creates a driving force for the water vapor to permeate through the film to the low pressure side. The barrier of the film determines how much water vapor can transfer, and this is continuously measured by an infrared detector in the outgoing stream of the dry side.
Figure 3: Cross-section of a WVTR test cell The test is complete when equilibrium, or steady state, is achieved, which is when the infra-red sensor detects water molecules leaving the dry chamber at a constant rate. The amount of water vapor permeating through the sample per unit time period is not changing. This rate is the sample WVTR and is recorded in units of g-H2O/100 in2/24 hr at 100F (37.8C), 90% RH. This overview describes how ExxonMobil measures WVTR and was based on articles and product literature provided by MOCON. There is much more to the science of mass transfer and to the instrumentation that
allows us to measure it. For more information, contact MOCON in Minneapolis, MN at (612) 493-6370, or visit http://www.mocon.com.
back to top
Related terminology
Normalized WVTR Normalized WVTR is equal to the measured WVTR multiplied by the gauge of the sample in mils. In other words, it is the approximated WVTR of the material at 1 mil thick. We provided normalized WVTR values in the first table of this write-up in order to compare the inherent moisture barrier property of different classes of materials. This technique is only appropriate with homogeneous films and is not appropriate for coated or metallized films.
***************************************************************************************** *
OTR
Definition Relevance to package performance What affects the OTR of films Test principles Related Terminology
Definition
OTR (oxygen transmission rate) is the steady state rate at which oxygen gas permeates through a film at specified conditions of temperature and relative humidity. Value are expressed in cc/100 in 2/24 hr in US standard units and cc/m2/24 hr in metric (or SI) units. Standard test conditions are 73F (23C) and 0% RH.
back to top
2. Vacuum packaging is where the atmosphere is drawn out and eliminated, rather than being replaced by another gas. This vacuum forces the flexible material to conform to the product shape. Meats (fresh and processed) and cheeses are commonly packaged this way. Once air has been replaced or eliminated from the package, there must be an adequate oxygen barrier and seal integrity to keep a low oxygen concentration inside the pack. Otherwise, the driving force created by the oxygen partial pressure differences (21% outside the bag and 0-2% inside the bag) will cause an ingress of oxygen and destroy the benefit of removing it in the first place. OTR values are used to compare the relative oxygen barrier capabilities of packaging films. An industry rule-of-thumb is that a material is considered a "high oxygen barrier" if its OTR is less than 1 cc/100 in 2/24 hr (15.5 cc/m2/24 hr). Table 10 shows OTR values for common polymer packaging films. Note that the table is divided into two sections. The first contains normalized (1 mil) values for common materials. The second section displays the OTRs for coated or metallized films where the total film thickness is unimportant, because the barrier is primarily coming from the additional layer. Film Type OTR @ 73F (23C), 0% RH (cc/100 in2/24 hr) (cc/m2/24 hr)
The following OTRs are bulk material properties displayed at 1 mil. You may divide by the gauge (in mil) in order to approximate OTR at a different thickness. EVOH* (ethylene vinyl alcohol) Biax Nylon-6 OPET (oriented polyester) OPP Cast PP HDPE (high density polyethylene) OPS (oriented polystyrene) LDPE (low density polyethylene) .005 - .12 1.2 - 2.5 2-6 100 - 160 150 - 200 150 - 200 280 - 400 450 - 500 .08 - 1.9 18.6 - 39 31 - 93 1550 - 2500 2300 - 3100 2300 - 3100 4350 - 6200 7000 - 8500
The following OTRs are enhanced by coating or metallizing. Therefore, these are not bulk film properties, and total film thickness has little impact on the OTR value. Metallized OPET PVOH-coated OPP (AOH) Metallized biax Nylon-6 PVdC-coated OPET High Barrier PVdC-coated OPP PVdC-coated biax Nylon-6 Metallized OPP Sealable PVdC-coated OPP Table 10: OTR values for common films *The range of possible values is especially wide for EVOH because the value is dependent on the ethylene content of the particular grade. EVOH is typically a buried layer, either via coextrusion or lamination. In order for film oxygen barrier to contribute its full product protection value, package seal integrity must be satisfactory. Poor quality seals can negate a film's good barrier by allowing oxygen transmission through channel leakers and imperfections. .01 - .11 .02 .05 .30 - .50 .30 - .60 .35 - .50 1.2 - 10 1.5 - 3.5 .16 - 1.7 .31 .78 4.7 - 7.8 4.7 - 9.3 4.7 - 7.8 19 - 160 23 - 54
CAUTION:
Related information: Many customers ask about the carbon dioxide (CO2) and nitrogen (N2) transmission rates through film. ExxonMobil does not perform transmission testing with these gases, but a value range can be estimated from OTR values by using the following relationships. CO2 TR will be 3 to 5 times the OTR value at 73F (23C), 0% RH N2 TR will be .2 to .4 times the OTR value at 73F (23C), 0% RH For example, the OTR of 110 AXT is .40 cc/100 in2/24 hr @ 73F (23C), 0% RH. Therefore, at the same conditions, the CO2 TR is approximately 1.2 - 2.0 cc/100 in2/24 hr and the N2 TR is approximately .08 to . 16 cc/100 in2/24 hr.
back to top
Test principles
ExxonMobil uses MOCON OX-TRAN@ instruments for measuring OTR. The instrument design and the way we operate the instrument are consistent with the ASTM D 3985 standard. ExxonMobil standardizes its reporting to test conditions of 73F (23C) and 0% RH. Conceptually, a test cell looks like Figure 4. Dry nitrogen gas is swept through a chamber, where the test film acts as the membrane separating this stream from an oxygen stream on the other side. The partial pressure difference creates a driving force for oxygen molecules to diffuse through the film to the low
pressure side. The film barrier determines the rate of oxygen permeation, and this is continuously measured by a MOCON patented coulometric sensor in the outgoing ,stream of the nitrogen side.
Figure 4: Cross-section of an OTR test cell The test is complete when equilibrium, or steady state, is achieved; that is, it is complete when the sensor detects a constant amount of oxygen in the nitrogen carrier stream. The rate of oxygen permeating through the sample is not changing. This rate is the sample OTR and is recorded in units of cc/100 in 2/24 hr or cc/m2/24 hr at 73F (23C), 0% RH. This discussion is an overview of how ExxonMobil measures OTR and was based on articles and product literature provided by MOCON. There is much more substance to the science and measurement of mass transfer. For more information, contact MOCON in Minneapolis, MN at (612) 493-6370, or visit www.mocon.com. It is important to discuss the effects of relative humidity on OTR, even though the ASTM standard procedure is at dry conditions. Relative humidity has a dramatic and negative effect on the OTRs of some materials, most notably nylon, EVOH and PVOH. The effect is especially pronounced at RHs over about 70%. AOH, with its PVOH coating, is the only ExxonMobil oxygen-barrier film affected this way. AOH should only be used as an oxygen barrier in dry applications. Consult your ExxonMobil representative.
NOTE:
back to top
Related terminology
PVdC PVdC stands for polyvinylidene chloride, but The Dow Chemical Company points out in the 2nd edition of The Wiley Encyclopedia of Packaging Technology that the use of this term is not precisely correct. PVdC suggests a homopolymer resin; when in fact, all commercial resins are VdC copolymers and should be referred to as such. Nevertheless, it is not likely that our industry will change its ways, where "PVdC" has become a generally accepted representation for the family of VdC copolymers.
Saran
Saran is a trademark of The Dow Chemical Company for its family of PVdC and VdC copolymer products.
Oxygen scavengers
Oxygen scavengers are materials that chemically react with oxygen in a package headspace. They can be used with MAP in order to attain very low oxygen concentrations (ppm levels) that are not achievable with MAP alone. Most oxygen scavengers used commercially are packets containing
iron powders that are placed inside a package and consume headspace oxygen through oxidation reactions.
***************************************************************************************** *
Opacity
Definition Relevance to performance What affects the opacity of OPPalyte films Test principles Related Terminology
Definition
Opacity represents a substrate's light blocking ability. It is primarily used as a property of paper and predicts the relative visibility on one side of the paper of the images that exist on the other side. Because white opaque films are replacing paper in some applications, ExxonMobil measures opacity for some white films. There are two common types of opacity measurements, and ExxonMobil uses the one called "89% reflectance backing," also called "contrast ratio." This value is equal to 100 times the ratio of the diffuse reflectance of a film sample backed by a black body (<.5% reflectance) to the diffuse reflectance of the same sample backed by a white body (89% reflectance). The units are percent, and a perfectly opaque material will have an opacity value of 100%.
back to top
Relevance to performance
Originally developed for paper, this property predicts the appearance of two-side printed paper. Higher opacity values allow better readability on one side, because the print showing through from the other side is less noticeable. Now, the same test used for paper is being applied to opaque polymer films that compete in paper markets, most notably labels. Depending on the product design and film thickness, opacity values for OPPalyte films range from 60% to 95%.
back to top
Test principles
TAPPI procedure T 425 and ASTM procedure D 589 describe the same standard protocol for determining the opacity of paper. ExxonMobil procedure #498 follows this protocol with only minor exceptions; the
most notable being that ExxonMobil does not precondition samples for 40 hours at standard laboratory conditions prior to testing. Although opacity has to do with light-blocking ability, the test actually measures two reflectance values. The ratio of these values times 100 is equal to percent opacity. The equation, with descriptions of the variables follows. Opacity (89% reflectance backing) = CO.89 = 100 (R0 + RO.89) CO.89 is the contrast ratio, which is another name for this type of opacity measurement. R0 is the reflectance of the substrate when it is backed by a black body of 0.5% reflectance or less. Any light that passes through a partially opaque sheet will reflect back negligibly. R0.89 is the reflectance of the substrate when it is backed by a white body having a reflectance of 89%. This value will be higher than R0 (or equal to it, if the sample is perfectly opaque) because any light that passes through the substrate will largely be reflected, and a portion of that will transmit through the film a second time (in the opposite direction). Opacity measurements are made with commercially available opacity meters that meet criteria stated in the standard procedures. The TAPPI Technical Services Department provides names of test equipment suppliers. ExxonMobil uses a Technidyne BNL-3 Opacimeter.
back to top
Related terminology
Light transmission Light transmission is the percentage of incident light that passes through a film. It is related to opacity, but cannot be calculated directly from it. In general, the lower the light transmission, the higher the opacity.
Optical density
Optical density is a measure of a material's light blocking ability and is theoretically equal to log10 (100 % light transmission). ExxonMobil uses optical density values with metallized films.
Oxygen scavengers
TAPPI stands for the Technical Association of the Pulp and Paper Industry. Among other things, it provides standard procedures for testing paper.
***************************************************************************************** *
Light Transmission
Definition Relevance to performance What affects light transmission Test principles Related Terminology
Definition
Light transmission is the percentage of incident light that passes through a film. ExxonMobil generally evaluates this property for OPPalyte films.
back to top
Relevance to performance
This property is significant to the performance of opaque films like OPPalyte. Customers expect these products to obstruct light transmission in a predictable way, which is important for the appearance of printed graphics and protecting light-sensitive packaged products. OPPalyte film light transmission values range from 15% to 50%, depending on the product design and film thickness. Metallized films are very effective at blocking light transmission, but the preferred test for these films is optical density.
NOTE:
back to top
Test principles
A unidirectional perpendicular light beam is directed onto the film specimen, and a photo detector measures the total light transmitted by the specimen after it enters an integrating sphere. Commercial hazemeters are typically used for this testing, but ASTM D 1003 also allows for the use of a spectrophotometer, provided that it meets the procedure requirements. ExxonMobil uses the BYK-Gardner XL-211 haze-gard and haze-gard plus hazemeters consistent with ASTM guidelines. The hazemeter when set up to measure light transmission will display the final result as a percentage to the nearest tenth.
The same test equipment with a different setup is also used to measure and display haze.
back to top
Related terminology
Luminous transmission Luminous transmittance refers to the same thing as light transmission. It is a more technical name used in the ASTM D 1003 test procedure title.
Haze
Haze is the scattering of light by a specimen, which results in a cloudy appearance or poorer clarity of objects when viewed through the film.
Translucent
Translucent is an attribute used to describe material that transmits light, but also diffuses it so that objects cannot be seen clearly.
Optical Density
Definition Relevance to performance What affects the optical density of metallized films Test principles Related Terminology
Definition
Optical density, which ExxonMobil measures with a transmission densitometer, is a representation of a material's light blocking ability. The optical density scale is unitless and logarithmic, and it enhances the data resolution for materials that transmit only a small fraction of incident light. ExxonMobil uses optical density measurements with metallized films only.
back to top
Relevance to performance
Transmission densitometers are traditionally used to evaluate the light transmission properties of photographic film. The same test is now used to also represent the thickness of the aluminum layer of vacuum-metallized films. Since layer thickness affects important performance-related properties like film barrier, light transmission, and appearance, optical density provides critical data for process control of the metallizing process. Depending on the product design, ExxonMobil metallized films have optical density values ranging from 2.0 to 3.0, which is equivalent to light transmission values of 0.1% to 1.0%.
back to top
Test principles
ExxonMobil data are provided by commercial densitometers that meet standard conditions defined by ANSI. A unidirectional, perpendicular light beam is directed onto the film sample. The light that is transmitted through the film is collected, measured, and logarithmically amplified. The densitometer calculates and displays the optical density value. ExxonMobil uses the Tobias TBX transmission densitometer and Macbeth models TD903 and TD932. The optical density values represent the following calculation and relationship to % light transmission.
Optical density values are reported to two decimal places. Table 11 compares optical density values to light transmission values in the range that exists for ExxonMobil metallized films. Optical density Light transmission (%) 2.00 1.0 2.10 0.8 2.20 0.6 2.30 0.5 2.40 0.4 2.50 0.3 3.00 0.1
Table 11: Light transmission values at various metallized film optical densities
back to top
Related terminology
ANSI ANSI stands for the American National Standards Institute.
Light transmission
Light transmission is the percentage of incident light that passes through a film sample. It can be calculated from optical density values.
Opacity
Opacity is a common paper measurement that describes a substrate's light-blocking ability. A perfectly opaque paper has an opacity value of 100%. Because white opaque films are replacing paper in some applications, ExxonMobil measures TAPPI opacity for some OPPalyte films.
TAPPI
TAPPI stand for the Technical Association of the Pulp and Paper Industry.
***************************************************************************************** *
Definition
Crimp seals, which are produced at controlled conditions of jaw design, temperature, pressure, and dwell, are measured in terms of force required to open the seam. The following properties are calculated and reported. Crimp seal strength is the maximum force to peel open a seal made at specified conditions. Units are gf/in or gf/2.5 cm.
Crimp minimum sealing temperature (Crimp MST) for a specified pressure and dwell, is the temperature (F or C) required to achieve a certain minimum strength seal. ExxonMobil has standardized with 200 g/in as the seal strength for minimum acceptable performance. Other values may be more appropriate for particular applications. Seal range is the difference between the maximum and minimum temperatures that will produce an adequate seal at a specified pressure and dwell. Units are of or C.
back to top
Relevance to performance
The strength of a seal is important to package integrity, and many end-users specify a minimum requirement. Crimp MST and seal range are important, because they predict packaging machine efficiency and productivity. A lower MST corresponds to a wider seal range and, therefore, a wider operating window. This means that the packaging line will produce acceptably sealed packages even when the speed is ramping up and down, or when there is variation in jaw temperature. On the other hand, a higher MST and narrower seal range forces the packager to control these variables better, or else packages can be rejected for weak, open seals, or distorted seals.
back to top
Seal properties are a key design criteria when developing a sealable film. In production, these properties are regularly measured to make sure that the formulation or process has not shifted.
back to top
Test principles
In order to compare sealing properties among different films, ExxonMobil uses a set of standard conditions for producing heat seals. They are summarized in Table 12. Condition Description
Wrap-Ade Crimp Sealer Model J or K, modified with new PID temperature controllers Vertically serrated crimps Both jaws are heated and desired set point is controlled to 2F (1C) 20 psi (1.4 bars) sec
Table 12: ExxonMobil conditions for producing test crimp seals After a test seal has been produced, its strength can be measured with a tensile tester or a Suter tester. ExxonMobil typically uses the simpler Suter tester, which pulls the seal apart at 12 in/min and records peak force. ASTM and ExxonMobil test procedures have similarities and differences. Unlike ExxonMobil, the scope of ASTM test procedure F 88 is only the measuring of the force to open the seal, not the making of the seal at a set of standard conditions. ASTM specifies the use of a tensile tester, while ExxonMobil uses a Suter tester. The 12 in/min pull rate of ExxonMobil is within the ASTM-defined a rate of 10 to 12 in/min. It is often desirable to produce seals at a series of temperatures, measure the seal strengths, and develop a seal curve that looks like in Graph 3.
Graph 3: Typical seal curve Crimp Seal Strength is defined at a particular temperature, or as the average for a range of temperatures. For the seal curve represented in Graph 3, the following properties can be derived. Seal Strength at 260F (SS260F) = 800 g/in SS260 - 300F = 790 g/in Minimum Sealing Temperature for a 200 g/in seal (MST 200g) = 200F (93C)
MST500g = 217F (103C) Seal Range (SR) = Maximum - Minimum Sealing Temperature SR200g = 300 - 200 = 100F (56C) SR500g = 300 - 217 = 83F (46C) The horizontal red line denotes a minimum acceptable seal strength of 200 g/in. It intersects the seal curve at 200F (93C), so this is the MST200g. If you know that the minimum acceptable seal strength is another value, the same curve may be used to determine the corresponding MST and seal range. For example, 500 g/in seals occur at 217F (103C), so this is the MST500g. Most OPPs will distort at temperatures above 300F (149C), if dwell time is in excess of second or so. Therefore, this value is used as the maximum sealing temperature. The difference between the maximum and minimum sealing temperatures is equal to the seal range. Seal data cannot be compared when the seals are produced on different equipment or at different conditions.
CAUTION:
back to top
Related terminology
ASKCO sealer The ASKCO sealer is a laboratory heat sealer that ExxonMobil uses for process control of coated films. It has nine separate temperature controlled, one-side heated, low-pressure, flat-sealing stations. The multiple stations allow a whole seal curve to be generated from one sealed film strip.
Sentinel sealer
The Sentinel sealer is a common laboratory heat sealer in the flexible packaging industry. Like the ASKCO sealer, it is a one-side heated, flat sealer. Unlike the ASKCO, there are no multiple stations, so it can only make a seal at one temperature at a time. ExxonMobil does not use this sealer. Data generated with the Sentinel sealer, by other companies, can not be compared with ExxonMobil data.
Failure mode
Failure mode refers to how the seal fails as it is being pulled apart. A "peel" failure means that the films separated without tearing. A "delamination" failure is a type of peel failure where the material separates between two adjacent layers, rather than at the sealing interface. (For example, a printed extrusion lamination can fail between the ink and poly layers, because they formed a weak bond.) Finally, a "tear" failure means that the film tears as the seal is being pulled apart. This suggests that the seal and the bonding between layers are stronger than the film.
Suter tester
strengths. It is simpler and speedier than using a tensile tester. Suter testers are not commercially available.
***************************************************************************************** *
Definitions Relevance to converting performance What affects the "treatment level" of OPP films Test principles Related Terminology
Definitions
All of the following terms are used in the polymer films industry to represent the relative receptivity of a film surface to the addition of inks, coatings, adhesives and extruded polymers. Surface energy is a solid surface characteristic associated with the molecular forces of its interaction with another material. Surface energy is the true film characteristic that we want to measure, but it can't be measured directly. So, we deduce this property by measuring one of two substitute properties: wetting tension or contact angle. Both of these measurements involve observing the behavior of liquids placed on the film's surface. Surface tension is the force that exists between a liquid and the atmosphere it is in. For example, in atmospheric air, a drop of water will bead up on some solid surfaces. It is the surface tension existing between the water and the air that allows this to occur. The drop of water can spread, or wet-out, on another solid surface if the new surface has molecular forces (surface energy) high enough to overcome the water/air surface tension and draw the water flat onto it. Wetting tension is the maximum liquid surface tension that will spread, rather than bead up, on the film surface. It is a measurable property that estimates a film's surface energy. ASTM D 2578 is a procedure for determining wetting tension by applying different test solutions of increasing surface tensions until one is found that just spreads (wets) the film surface. Units are dynes/cm. Treatment level refers to "how much" or "how well" the polymer film surface was treated in the film-making process. It is most commonly quantified with a wetting tension value in units of dynes/cm. Therefore, you will also hear it called "dyne level." Treatment level, dyne level, surface energy, surface tension, and wetting tension are all terms frequently used interchangeably. As you can see from the definitions, this is not precisely correct. Wetting tension, which is the term ASTM uses, is the correct term to describe the value determined by the test solutions procedure. Contact angle is a measurement of the behavior of pure water in contact with the film surface. (Other liquids of known surface tension could be used, but water is most commonly used.) The ASTM D 5946 procedure requires a precise volume droplet of pure water be placed on the film
NOTE:
surface. The surface energy of the film controls whether the droplet tends to stand up or flatten out. This is quantified by measuring the contact angle of the droplet with the surface. A higher energy ("higher treatment") film will cause the droplet to be flatter and closer to the surface, which results in a smaller contact angle value (8). Units are degrees, or the result can be reported as (unitless) cosine 8. ExxonMobil uses a dynamic contact angle (DCA) tester to evaluate the same property. Our test is substantially different than the ASTM standard and may not produce comparable results.
back to top
Film Polytetrafluoroethylene (PTFE, Teflon) Polypropylene (PP) Polyethylene (PE) Polyester (PET)
Table 13: Wetting tensions (as an estimate of surface energy) of common untreated polymer surfaces In extrusion lamination or extrusion coating processes, a molten extrudate (not a liquid solution) is being applied to the film surface. Wet-out is not an issue, but an adequate surface energy is required for good bond strengths. Some polymer films, most prominently, polyethylene and polypropylene, have inherently low surface energies, and these surfaces need to be modified to be "converter-processable." The easiest and most common modification is called "treatment" ExxonMobil uses two in-line treatment processes to increase the energy, polarity, and processability of film surfaces. 1. Corona treatment involves exposing a moving film surface to a plasma discharge created in the air gap between a grounded electrode and a high-voltage electrode. The plasma is purple glowing ionized air that reacts chemically with the film surface. Oxidation reactions occur, which add polar functional groups and increase surface energy. 2. Flame treatment exposes a moving film surface to a gas-fired flame at a high enough temperature to create a plasma of free oxygen and nitrogen atoms, electrons, and ions. The plasma reacts chemically with the film surface, which adds polar functional groups and increases surface energy. Depending on the product design, a treated OPP film will have a wetting tension between 35 and 55 dynes/cm. This whole range of values works well in most flexpack converting applications. Challenging situations, like some water-based applications, may require films in the higher end of the range. For example, the treated high-energy surfaces of LBW and CSR-2 with wetting tensions of 50 to 55 dynes/cm provide exceptional wet-out and adhesion in challenging applications.
back to top
CAUTION:
back to top
Test principles
There are two tests used to estimate the surface energy of a film: wetting tension and contact angle. Each has its advantages and disadvantages, which are described in Table 14. For over five years, ExxonMobil has been expanding its use of the contact angle test as a process control measurement. Because of the improved data quality, ExxonMobil will continue to do so. ExxonMobil procedure #417 uses a Cahn Model DCA-312 or DCA-315 to measure dynamic contact angle (DCA). Unlike the ASTM contact angle test that applies a single water droplet, our Cahn test immerses a prepared film sample into a beaker of distilled water at a constant rate of speed, while a sensitive balance records the wetting force. The Cahn DCA software contains well established theoretical calculations, which convert this measurement into advancing and receding contact angle values. ExxonMobil has standardized on recording the cosine of the receding contact angle value.
Test Attributes Test results variation Cost of test equipment Speed and simplicity
Table 14: Comparison of basic test attributes A more common, but less reliable, test is wetting tension, as described in ASTM D 2578. This method uses standard wetting tension solutions consisting of varying ratios of formamide in cellosolve to create different surface tensions. A test solution is selected that is rated less than the anticipated film value. Using a new cotton-tipped applicator, the solution is applied in a zigzag pattern over about one square inch of film. If the applied solution holds together for more than two seconds, rather than breaking up into droplets, then the test is repeated with the next higher surface tension solution. If the solution holds together for less than two seconds, the test is repeated with a lower surface tension solution. This scenario is reiterated until you can determine the solution that comes nearest to wetting the film surface for exactly two seconds. This is the film's wetting tension. A new cotton applicator must be used each time to prevent contamination of the solutions. A new section of film must be tested with each iteration.
back to top
Related terminology
Dyne test Dyne test is a commonly used name for the wetting tension test, because it uses solutions that are rated at different dynes/cm.
Wet-out