Sie sind auf Seite 1von 4

TANGEDCO

A Subsidiary of TNEB LIMITED TANGEDCO a subsidiary of TNEB Ltd is conducting 6 Days 11KV High Voltage (HT) Heat Shrinkable Power Cable Jointing & End

Termination - Hands on Practical Training Course for outside persons other than TANGEDCO / TANTRANSCO
VENUE Cable Jointing Training & Development Centre 33/11KV Nehru Indoor Stadium Sub-Station (1st Floor) TANGEDCO, Kannappar Thidal, Periamet, (Near Choolai post office) Chennai 600 003. Tamilnadu/ India DATE & TIME : I Batch - Sep/2012 Completed II Batch Tentatively March / 2013 3rd Week

Objective of the Training Course: To enable the participants to perform the 11KV High Voltage XLPE Power Cable Heat Shrinkable Joint & End Termination individually in a systematic & professional manner and make them as Skilled Jointers. Target Participants /Entry Requirements: The individuals who have completed the hands on practical low voltage (LV/LT) heat shrinkable power cable jointing training certificate course, certified from the reputed institutes/ organization are eligible to participate in this 11 KV Hands on Practical Heat Shrinkable Power Cable Jointing & Termination training course. individual participants or by the sponsoring authorities. Admission restricted to 12 Participants only and it will be on First come First Serve basis. NOTE: Only Participants who have Low Voltage Heat Shrinkable Jointer Certificate are permitted & admitted for this training course. The TA & DA have to be borne by the

Training participation Fee: Fee is Rs. 20,000/- ( Rupees Twenty Thousand only) per participant (Inclusive of Power Cable, Jointing kits, Course Material, Lunch, mid Coffee / Tea & Snacks). Fee must be paid in the form Demand Draft, drawn in favour of TANGEDCO COLLECTION ACCOUNT, Chennai-2, payable at Chennai. Details of the Training Programme. Name of the training programme Duration Number of Participants Number of Groups Number of Jointing & Termination kits proposed for hands on practical Description of Power Cable, Jointing Kit & Termination Kit : : : : : : 11KV High Voltage (HT) Heat Shrinkable XLPE Power Cable Jointing & End Termination Hands on Practical Training Course 6 Days Non Residential 12 Nos. 3 Groups (i.e 4 Persons per Group) 1No. for each group = (i.e 1 kit for 4 Persons) For Demonstration 1no. Jointing & 1no. Termination Kit 11KV 3*120 sq.mm XLPE Power Cable (3 Core Cable) 11KV 3*120 sq.mm (3 core) Heat shrinkable Jointing Kits 11KV 3*120 sq.mm (3 core) Heat shrinkable Termination Kits Both in English & Tamil

Medium of instruction

Training course contents & Programme Agenda


6 Days Hands on Practical 11KV High Voltage (HT) Heat Shrinkable Power Cable Jointing & Termination Training Programme Day1 Day2 10.00 to 11.30 Hrs Introduction & Architecture of Power Cables Group Discussion/ Viva-voce about Power Cables & Evaluation of Accessories of Jointing Kit Group Discussion / Viva-Voce Oral & written narrative report / Test about 11KV HS St. Joint 11.45 to 13.15 Hrs 14.00 to 15.30 Hrs 15.45 to 17.00 Hrs Laying, Earthing & General Electrical Jointing & Termination Installation of Power Cables Safety of Power Cables Practical Demonstration of 11KV XLPE Power Cable Heat Shrinkable Straight Joint Group (4 persons per Group) Practical Session of 11KV XLPE Power Cable Heat Shrinkable Straight Joint Field Visit - Demonstration of End Termination in the Field Group (4 persons per Group) Practical Session of 11KV XLPE Power Cable Heat Shrinkable End Termination Final Written Test Group Discussion/ Feed Back/ Suggestions

Day3

Day4 Day5

Practical Demonstration of 11KV XLPE Power Cable Heat Shrinkable End Termination Group Discussion / Oral & written narrative report about 11KV HS End Termination Lecture & Practical demonstration of Fault Location & Fault finding Video Presentation of 11KV XLPE Cable HS St. Joint / End Termination Testing of the finished New Joint & Termination

Day6

Tea Break :

11.30 to 11.45 Hrs. 15.30 to 15.45 Hrs Lunch Break: 13.15 to 14.00 Hrs

Profile of the Training Centre & Facilities available at CJT&DC:

The Cable Jointing Training and Development Centre (CJT&DC) was established in TNEB (Now TANGEDCO) at Chennai during the year 1962 and training is being imparted to the trainees both in theory and practical. Unique Feature CJT&DC is an exclusive & only training centre which gives Hands on practical training to the work force (Field Staff) in the field of Power Cable Jointing & make them as Skilled Jointers. It is unique in its kind in India. Special Feature In CJT&DC, 1batch of Hands on Practical 11KV High

High Voltage Hands on Practical Session

Voltage (HT) Heat Shrinkable Power Cable Jointing Training Course was already conducted for outside persons (i.e persons other than TANGEDCO/TANTRANSCO) during the period Nov2011 and 12 persons have been trained to become 11KV High Voltage Cable Jointers. The certificate issued by this centre is very valuable and very much recognized in overseas. The cable jointers trained from this institute are getting overseas employment opportunities.

Faculty Details: This Centre has 4 Core Faculties (2 Engineers & 2 Jointers) having good experience. Both the theory and practical training is imparted to the trainees by the experienced TANGEDCO (TNEB) Engineers, Skilled jointers, Eminent persons from Cable & Jointing Kit manufacturing firms, etc.

For further details kindly contact, Er. R. Prabhavathi Senior Manager/ HRD Cable Jointing Training & Development Centre 33/11KV Nehru Indoor Stadium Sub-Station (1st Floor) TANGEDCO, Kannappar Thidal, Periamet, (Near Choolai post office) , Chennai 600 003./ Tamil Nadu / India. Contact No : Phone No: 044 25383165 Mobile No:+91- 9445850814 E-mail Id : aeecjtc@tnebnet.org Registration Form Sl. No 1 2 Name Designation/ Participant Status Nominated by or Nomination Fee details Individual Nomination ( DD details) Address/ Phone No. & E-Mail Id

Das könnte Ihnen auch gefallen