Agilent E7574A Datacom 4-Link Interface Module

Reference Manual

Copyright 2002 Agilent Technologies, Inc. All rights reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. Part No. 37907-90232 First edition, January 2002 Printed in U.K.

Documentation Warranty
The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.

SAFETY
Warning

Warning denotes a hazard. It calls attention to a procedure, which if not correctly performed or adhered to could result in injury or loss of life. Do not proceed beyond a warning note until the indicated conditions are fully understood and met.
Caution Caution denotes a hazard. It calls attention to a procedure, which if not correctly performed or adhered to could result in damage to or destruction of the instrument. Do not proceed beyond a caution note until the indicated conditions are fully understood and met. For details of safety, see Safety Symbols, page 28.

Trademarks
Microsoft is a U.S. registered trademark of Microsoft Corporation. Windows and MS Windows are U.S. registered trademarks of Microsoft Corporation.

Product Support
Call your local Agilent Technologies representative, or: Tel: 1-800-452-4844 Fax: 303-754-4802 or call your local Agilent Sales and Service Office.

Agilent Technologies 5070 Centennial Boulevard Colorado Springs, CO 80919-2497 USA

Reference Manual

Agilent E7574A Datacom 4-Link Interface Module

Introduction

The interface module provides the physical connection between the Signaling Advisor and the network you are testing. The interface module extracts the signaling information from up to four duplex links and adds a timestamp to the captured data before routing it to the Signaling Advisor for storage and analysis.

Sources of information about the Signaling Advisor


The documentation supplied is listed below: Mainframe Reference Manual - This manual describes the Signaling Advisor hardware. It also covers the connection and configuration of accessories via PC Cards in the PCMCIA slots. Users Manual - This manual tells you how to use the Signaling Advisor to monitor and emulate signaling data, view and interpret the results. Software Recovery Guide - This manual provides detailed instructions for reinstalling Windows and the Signaling Advisor System Software. (Note: Your instrument is shipped with all software installed.) Interface Module Reference Manuals - Each interface module is provided with a manual which tells you how to install and verify the operation of the module. Unpacking and Installation Card - Identifies the items you will typically receive with your instrument. It also shows you how to proceed when you first receive your instrument. Quick Start and Quick Reference - A summary of useful operating information. Registration and Initial Setup for the Signaling Advisor - Contains the preliminary procedures you need to follow when you first receive your instrument. Signaling Advisor Undercradle Installation Manual (Optional) - This manual contains installation instructions on how to connect/disconnect the undercradle to/from Signaling Advisor. On-Line Help - The help comprises three parts: on-line help, context sensitive help, and copies of the manuals supplied with the instrument, support information, configuration information and frequently asked questions. Microsoft Windows on-line help is also available. Web Site - http://onenetworks.comms.agilent.com/

List of Contents

List of Contents

Installing an Interface Module ............................................................................. Connecting Interface Modules to Bearers............................................................ Cabling Information .......................................................................................... Connecting to a V35, RS-449 or RS-232 Network Monitor Point ................... Connecting for End Emulation.......................................................................... V.35 J4201A Cable Interconnections................................................................ RS-449 J4202A Cable Interconnections ........................................................... RS-232 J4203A Cable Interconnections ........................................................... Verifying Correct Operation ................................................................................ Description ........................................................................................................ Verification Prerequisites .................................................................................. Procedure........................................................................................................... Product Identification ....................................................................................... Build Status ....................................................................................................... Statement of Compliance ..................................................................................... Electromagnetic Compatibility (EMC) Information ......................................... Safety Information............................................................................................. Noise Declaration (German) ............................................................................. Declaration of Conformity ................................................................................... Safety Symbols..................................................................................................... ESD Precautions................................................................................................... Cleaning the Product ............................................................................................ Calibration Cycle.................................................................................................. Operating Environment ....................................................................................... Storage and Shipment........................................................................................... Returning for Service ........................................................................................ Weight and Dimensions .................................................................................... Web Site for Additional Product Information......................................................

5 7 8 11 12 13 16 19 22 22 22 23 25 25 26 26 26 26 27 28 29 29 30 30 31 31 32 32

Installation and General Information Installing an Interface Module

Installing an Interface Module


You can have up to two modules installed in your Signaling Advisor. However, the number of modules can be extended by up to two if you have an undercradle fitted. The modules operate in either slot. If only one module is fitted to your Signaling Advisor then a Filler Panel must be fitted to the empty slot. WA RN IN G If this product is not used as specified, the protection provided by the product could be impaired. This product must be used in a normal condition only (in which all means for protection are intact).

CA UT I O N

To prevent possible system errors, you must turn off the power to the Signaling Advisor before installing or removing a module.

To install a module (or Filler Panel) into a Signaling Advisor: 1 2 3 Ensure the Module Release Latch is in the unlocked position. Fit and slide the module (or Filler Panel) into the opening on the side of the instrument, see the following figure. Push the module firmly into place until it is seated (the Module Release Latch automatically moves to the locked position). If you are fitting a Filler Panel, you will need to manually move the Module Release Latch to its locked position.

LATCH

INTERFACE MODULE

Installation and General Information Installing an Interface Module

To remove an interface module (or Filler Panel) from a Signaling Advisor: 1 2 Depress the left end of the Module Release Latch (labeled PUSH TO UNLOCK) then slide the latch to the left end (unlocked position). Pull the module (or Filler Panel) out of the module.
UP

Pull knob goes toward outside of Signaling Advisor

To install an interface module into an undercradle: 1 2 3 Switch off the power to the instrument. Fit and slide the module into the opening of the undercradle. Push it into place until it is seated, see the figure below.

To remove an interface module from an undercradle: 1 2 Slide the Module Release Latch towards the left. Pull the module out of the undercradle.

For more information, refer to the Installation Manual that is shipped with the undercradle.

Installation and General Information Connecting Interface Modules to Bearers

Connecting Interface Modules to Bearers


Connections to the network are made with the two connectors on the interface module. Each connector provides two V.35/RS-449/RS-232 full duplex links in Monitor mode. In Emulate mode, the interface module can transmit V.35/RS-449/RS-232 signals. CA UT I O N The ports on this module go low impedance when the Signaling Advisor is switched off. If any port is connected to an unprotected monitor point, disconnect the cable from the Signaling Advisor before powering off, otherwise the low impedance state could adversely affect the network.

Bearers 1 and 2 CA UT I O N

Bearers 3 and 4

When connecting or disconnecting, ensure that you are grounded or, make contact with the metal surface of the mainframe with your free hand to bring you, the module, and the Signaling Advisor to the same static potential. Modules remain susceptible to ESD damage while the module is installed in the Signaling Advisor. Additional ESD precautions are required when servicing, see page 29.

NOT E

The Bearer settings will be disabled when there is no adapter cable fitted, or when an invalid or unsupported cable is fitted, or when the loopback connector is fitted.

Installation and General Information Connecting Interface Modules to Bearers

Cabling Information
Description V.35 Dual Link cable. Length 2m Part No. J4201A

For V.35 interconnections, see page 13. RS-449 Dual Link cable. 2m J4202A

For RS-449 interconnections, see page 16.

Installation and General Information Connecting Interface Modules to Bearers

Description RS-232 Dual Link cable.

Length 2m

Part No. J4203A

For RS-232 interconnections, see page 19.

Installation and General Information Connecting Interface Modules to Bearers

Description Self Test Loopback connector. Interconnections Pin 1 2 3 4 5 12 14 26 27 28 29 30 All other pins not used. SCSI-1 to SCSI-2 cable. Pin 25 24 23 22 21 37 39 50 49 48 47 46

Length 2m

Part No. J4204A

2m

J4208A

All pins are connected with one to one mapping.

10

Installation and General Information Connecting Interface Modules to Bearers

Connecting to a V35, RS-449 or RS-232 Network Monitor Point


The module is automatically configured for a V.35, RS-449 or RS-232 network when you switch on the Signaling Advisor and the appropriate V.35, RS-449 or RS-232 adapter cable is fitted to the module via the J4208A cable. The adapter cable currently being used and the other module settings are displayed in the Signaling Advisor s Bearer view. CA UT I O N The ports on this module go low impedance when the Signaling Advisor is switched off. If any port is connected to an unprotected monitor point, disconnect the cable from the Signaling Advisor before powering off, otherwise the low impedance state could adversely affect the network. For more information on configuring the Signaling Advisor s V.35/RS-449/RS-232 bearer settings in Monitor mode, refer to the instruments On-Line Help. The following diagram shows how you make a bridged connection on a duplex link when a monitor point is available.

The maximum combined length for the link plus drop cable is 15 m (RS-232), 1200 m (RS-449) and 100 m (V.35).

11

Installation and General Information Connecting Interface Modules to Bearers

Connecting for End Emulation


In Emulate mode, you can send and receive messages to/from another piece of Network Equipment. The Signaling Advisor terminates the Receive side of the Bearer and generates V.35/RS-449/RS-232 compatible signals on the Transmit side. Maximum cable length depends on cable quality and will typically be >15 m (RS-232), >1200 m (RS-449) and >100 m (V.35) For more information on configuring the Signaling Advisor s V.35/RS-449/RS-232 bearer settings in Emulate mode, refer to the instruments On-Line Help.

12

Installation and General Information Connecting Interface Modules to Bearers

V.35 J4201A Cable Interconnections


The pin assignment for V.35 connectors (J1, P1 and J2, P2) is shown in the following table:
Direction DCE Direction DTE

Pin
A B C D E F H J K R T V X P S U

Circuit
AA AB CA CB CC

Signal Name
Protective Ground Signal Ground Request to Send Clear to Send Data Set Ready

Mnemonic
Shield GND

Input Output Output

Output Input Input

CD

Data Terminal Ready

RD(A) RD(B) SCR(A) SCR(B) SD(A) SD(B) SCTE(A)

Received Data Received Data Serial Clock Receive Serial Clock Receive Send Data Send Data Serial Clock Transmit External DTE Source

RXD-A RXD-B RXC-A RXC-B TXD-A TXD-B XTC-A

Output Output Output Output Input Input Input

Input Input Input Input Output Output Output

SCTE(B)

Serial Clock Transmit External DTE Source

XTC-B

Input

Output

SCT(A)

Serial Clock Transmit DCE Source

TXC-A

Output

Input

AA

SCT(B)

Serial Clock Transmit DCE Source

TXC-B

Output

Input

BB Z EE CC

13

Installation and General Information Connecting Interface Modules to Bearers

The V.35 J4201A Dual Link cable pin assignment is shown below:

14

Installation and General Information Connecting Interface Modules to Bearers

The V.35 Y Dual Link cable pin assignment is shown below:

15

Installation and General Information Connecting Interface Modules to Bearers

RS-449 J4202A Cable Interconnections


The pin assignment for RS-449 connectors (J1, P1 and J2, P2) is shown in the following table:
Direction DCE Direction DTE

Pin
1 2 3 4 5 6 7 8 9 11 12 17 19 20 21 22 23 24 25 26 27 29 30 35

Circuit
Shield

Signal Name
Ground +5 V Power +12 V Power

Mnemonic
Shield

SD(A) ST(A) RD(A) RS(A) RT(A) CS(A) DM(A) TR(A) TT(A) SG

Send Data Send Timing (DCE source) Receive Data Request to Send Receive Timing Clear to Send Data Mode Terminal Ready Terminal Timing (DTE source) Signal Ground Ground for power -12 V Power

TXD-A TXC-A RXD-A RS-A RXC-A CS-A DM-A TR-A XTC-A

Input Output Output Input Output Output Output Input Input

Output Input Input Output Input Input Input Output Output

SD(B) ST(B) RD(B) RS(B) RT(B) CS(B) DM(B) TR(B) TT(B)

Send Data Send Timing (DCE source) Receive Data Request to Send Receive Timing Clear to Send Data Mode Terminal Ready Terminal Timing (DTE source)

TXD-B TXC-B RXD-B RS-B RXC-B CS-B DM-B TR-B XTC-B

Input Output Output Input Output Output Output Input Input

Output Input Input Output Input Input Input Output Output

16

Installation and General Information Connecting Interface Modules to Bearers

The RS-449 J4202A Dual Link cable pin assignment is shown below:

17

Installation and General Information Connecting Interface Modules to Bearers

The RS-449 Y Dual Link cable pin assignment is shown below:

18

Installation and General Information Connecting Interface Modules to Bearers

RS-232 J4203A Cable Interconnections


The pin assignment for RS-232 connectors (J1, P1 and J2, P2) is shown in the following table:
Direction DCE Direction DTE

Pin
1 2 15

EIA
AA BA DB

CCITT
103 114

Signal Name
Protective Ground Transmitted Data Transmit Clock (DCE source)

Mnemonic
Shield TXD TXC

Output Input

Input Output

7 3 17

AB BB DD

102 104 115

Signal Ground Received Data Receive Clock (DCE source)

GND RXD RXC

Input Input

Output Output

24

DA

113

Transmit Clock (DTE source)

XTC

Output

Input

19

Installation and General Information Connecting Interface Modules to Bearers

The RS-232 J4203A Dual Link cable pin assignment is shown below:

20

Installation and General Information Connecting Interface Modules to Bearers

The RS-232 Y Dual Link cable pin assignment is shown below:

21

Installation and General Information Verifying Correct Operation

Verifying Correct Operation


Description
You verify correct operation in Post Capture mode, by selecting All Tests from the Signaling Advisors built-in Self Test function. When you select All Tests, the program automatically detects which interface module(s) are housed in the Signaling Advisor, it then selects and runs the appropriate self tests. It takes approximately 15 minutes to verify each interface module. The default settings are used which means tests will continue to completion (even if an error is detected), and all results (Pass or Fail) will be logged to disk. For a detailed description of Self Test, refer to the instruments On-Line Help. CA UT I O N To prevent network disruptions, ensure the Signaling Advisor is disconnected from your network before you run Self Tests.

Verification Prerequisites
During Self Test you will be prompted to fit external loopback cables. To minimize verification time ensure that you have following cables available before you start the Self Test: Self Test Loopback connector, part number Agilent J4204A. Clock loopback cable (connects to the Signaling Advisor CLOCK/TRIG IN and OUT ports), part number Agilent 8120-8820. Telephone handset (this is an optional connection), part number Agilent 15722A.

22

Installation and General Information Verifying Correct Operation

Procedure
1 Double-click the Signaling Advisor icon in the desktop.

2 3

Click the Post Capture button. Click on the Tools menu, then select Self Tests.

23

Installation and General Information Verifying Correct Operation

Click the All Tests button, then click Run Tests.

Test progress and results can be viewed on the screen. A full set of results is available from the specified log file. If any of the Self Tests fail, see Returning for Service, Page 31.

Click the Close button to exit Self Test and return to the Monitor application.

24

Installation and General Information Product Identification

Product Identification
Attached to the product is a serial number plate. The serial number on this label is in the form GB00000101. The option number on this label indicates which hardware options are fitted.

The contents of this manual apply to products with serial numbers GB00000101 and above.

Build Status
Also attached to the product side panel is a BUILD STATUS label which indicates the revision of hardware built into this product.

If you contact Agilent for service on this product the Agilent engineer may request the Build Status number.

25

Installation and General Information Statement of Compliance

Statement of Compliance
Electromagnetic Compatibility (EMC) Information
This product conforms with the protection requirements of European Council Directive 89/336/EEC for Electromagnetic Compatibility (EMC). The conformity assessment requirements have been met using the technical Construction file route to compliance, using EMC test specifications EN 55011:1991 (Group 1, Class A) and EN 50082-1:1992. In order to preserve the EMC performance of the product, any cable which becomes worn or damaged must be replaced with the same type and specification. See the Declaration of Conformity on the next page.

Safety Information
This product has been designed and tested in accordance with publication EN610101(1993) / IEC 61010-1(1990) +A1(1992) +A2(1995) Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, and has been supplied in a safe condition. The instruction documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the instrument in a safe condition.

Noise Declaration (German)


LpA<70dB am Arbeitsplatz (operator position) normaler Betrieb (normal position) nach DIN 45635 pt.19 (per ISO 7779)

26

Installation and General Information Declaration of Conformity

Declaration of Conformity

DECLARATION OF CONFORMITY
According to ISO/IEC Guide 22 and CEN/CENELEC EN45014 Manufacturers Name: Manufacturers Address: Agilent Technologies UK Limited
Telecomms Networks Test Division South Queensferry West Lothian, EH30 9TG Scotland, United Kingdom

Declares that the product Product Name: Model Number: Product Options:
Datacom Line Interface Module E7574A This declaration covers all options of the above product as detailed in TCF A-5951-9852-01.

EMC:
Conforms with the protection requirements of European Council Directive 89/336/EEC on the approximation of the laws of the member states relating to electromagnetic compatibility, against EMC test specifications EN 55011:1991 (Group 1, Class A) and EN 50082-1:1992. As Detailed in: Assessed by: Electromagnetic Compatibility (EMC) Technical Construction File (TCF) No. A-5951-9852-01 DTI Appointed Competent Body EMC Test Centre, GEC-Marconi Avionics Ltd., Maxwell Building, Donibristle Industrial Park, Hillend, Dunfermline KY11 9LB Scotland, United Kingdom Technical Report Number:6893/2200/CBR, dated 21 August 1997

Safety:
The product conforms to the following safety standards: IEC 61010-1(1990) +A1(1992) +A2(1995) / EN 61010-1(1993) The product herewith complies with the requirements of the General Product Safety Directive 92/59/EEC. South Queensferry, Scotland. 15 May 2000

For further information, please contact your local Agilent Technologies sales office, agent, or distributor.

27

Installation and General Information Safety Symbols

Safety Symbols
Safety Symbols Description
The Instruction Documentation Symbol. The product is marked with this symbol when it is necessary for the user to refer to the instructions in the supplied documentation. Indicates hazardous voltages.

Indicates the field wiring terminal that must be connected to earth ground before operating the equipment - protects against electrical shock in case of fault. Frame or chassis ground terminal - typically connects to the equipments metal frame. WARNING Warning denotes a hazard. It calls attention to a procedure, which if not correctly performed or adhered to could result in injury or loss of life. Do not proceed beyond a warning note until the indicated conditions are fully understood and met. Caution denotes a hazard. It calls attention to a procedure, which if not correctly performed or adhered to could result in damage to or destruction of the instrument. Do not proceed beyond a caution note until the indicated conditions are fully understood and met. This symbol indicates that a device, or part of a device, may be susceptible to electrostatic discharges (ESD) which can result in damage to the product. Observe ESD precautions given on the product, or its user documentation, when handling equipment bearing this mark. The CE mark shows that the product complies with all relevant European Legal Directives. The C-Tick mark is a registered trademark of the Australian Communications Authority. This signifies compliance with the Australian EMC Framework Regulations under the terms of the Radio Communications Act of 1992. ISM 1-A ICES/NMB-001 This is a symbol of an Industrial, Scientific, and Medical Group 1 Class A product. This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme la norme NMB-001 du Canada.

CAUTION

28

Installation and General Information ESD Precautions

ESD Precautions
CA UT I O N When making connections to the modules, review Connecting Interface Modules to Bearers, Page 7. The module contains components sensitive to electrostatic discharge. To prevent component damage, carefully follow the handling precautions presented below. The smallest static voltage most people can feel is about 3500 volts. It takes less than one tenth of that (about 300 volts) to destroy or severely damage static sensitive circuits. Often, static damage does not immediately cause a malfunction but significantly reduces the components life. Adhering to the following precautions will reduce the risk of static discharge damage. Keep the module in its conductive storage box when not installed in the Signaling Advisor. Save the box for future storage of the module. Before handling the module, select a work area where potential static sources are minimized. Avoid working in carpeted areas and non-conductive chairs. Keep body movement to a minimum. Agilent recommends that you use a controlled static workstation. Handle the module by its front-panel. Avoid touching any components or edge connectors. When you install the module, keep one hand in contact with the protective bag as you pick up the module with your other hand. Then, before installing the module, ensure that you are grounded or make contact with the metal surface of the Signaling Advisor with your free hand to bring you, the module, and the Signaling Advisor to the same static potential. This also applies whenever you connect/disconnect cables on the front-panel.

Cleaning the Product


Use a soft, clean damp cloth to clean the outer surfaces.

29

Installation and General Information Calibration Cycle

Calibration Cycle
This product does not require periodic calibration. Operational verification can be confirmed by running the built-in Self Test, see page 22.

Operating Environment
This product is designed for indoor use only. DO NOT operate the product in an explosive atmosphere or in the presence of flammable gasses or fumes. This product may be operated in environments within the following limits: Temperature: Altitude Humidity +5o C to +40o C up to 4,600 m 20% to 80% relative humidity non condensing to 40oC. This product should be protected from temperature extremes which may cause condensation within the product enclosure.

To ensure adequate cooling do not obstruct air vents in the product cabinet. Air vents are located at the front, on the underside and both sides of the product. CA UT I O N This product is designed for use in Installation Category II and Pollution Degree 2 per IEC 61010 and 60664 respectively.

30

Installation and General Information Storage and Shipment

Storage and Shipment


This product may be stored or shipped in environments within the following limits: Temperature Altitude Humidity -25o C to +60o C Up to 15,250 m 10% to 90% relative humidity to 60oC

This product should be protected from temperature extremes which could cause internal or external condensation.

Returning for Service


When returning this product for service, please include the Signaling Advisor and accessory cables. Tagging for Service. If the module is being returned to Agilent for service, please complete a repair tag and attach it to the module. Ensure the following information is sent with it: Description of the problem (include the self-test results file, error messages or specific performance data related to the problem). Whether the problem is constant or intermittent. Name and phone number of technical contact person. Return address. Model and option number of returned Signaling Advisor and module(s). Full serial numbers of returned Signaling Advisor and module(s). Mark shipping container FRAGILE to ensure careful handling. Original Packaging. Containers and materials identical to those used in factory packaging are available from Agilent offices. Other Packaging. The following general instructions should be followed when repackaging with commercially available materials: Wrap instrument in heavy paper or plastic. Use a strong shipping container. A double wall carton made of 350 pound test material is adequate.

31

Installation and General Information Web Site for Additional Product Information

Use a layer of shock absorbing material 70 to 100 mm (3 to 4 inch) thick, around all sides of the instrument to provide firm cushioning and prevent movement inside the container. Do not rely on pellets for shock absorption, as during transit the instrument will sink to the bottom of the pellets. Seal shipping container securely.

Weight and Dimensions


Weight: 0.5 kg Dimensions: (height x width x depth) 21 mm x 122 mm x 150 mm

Web Site for Additional Product Information


You can use the Signaling Advisor to access the Web (requires a suitable LAN or modem connection), or you can use any suitable PC with access to the Web. http://onenetworks.comms.agilent.com/

32

Sales and Service Offices


An up-to-date list of Agilent Offices is available through the Agilent Website at URL:

http://onenetworks.comms.agilent.com/

In this book

You will be shown how to install an E7574A Datacom 4-Link Interface Module into a Signaling Advisor. Also provided is cabling information and a verification procedure.