Sie sind auf Seite 1von 10

Convenience in door opening

Automatic Card authentication Double authentication feature (Pin & Card Key) Force Lock features

Fire Alarm & Emergency features External anti-crime feature

www.EzonWorld.com
ezonsales@gmail.com

Product Parts (Outside)


Number Pad off Touch the number pad Number Pad Number Pad Battery lamp Pad Number Card Sensor Reset Hole Emergency Battery terminal Number Pad On

Product Parts (Inside)


Registration button Open button Manual lock/unlock lever Deadbolt Door Open Sensor

Automatic/Manual Lock Mode switch Open battery compartment cover

Press the battery compartment cover lightly then slide the cover following the arrow direction

Opening door outside (Pin Number)


Opening the door from the outside (Pin Number). The double authentication mode is enabled in default. To change the authentication process to normal mode please follow the instruction below 1. Touch the number pad

2. Enter Pin Number Double Authentication Mode

Bee~ree ~reep
2 random numbers will be lighted on the screen. Press the 2 numbers When the number pad completely lights-up enter pin number followed by [*] button button

Normal Authentication Mode

Bee~ree ~reep

When the number pad completely lights-up enter pin number followed by [*] button

-Enter pin number immediately when the number pad lights up, when the number pad light turns off touch the number pad again -When wrong pin number is entered, press the [House] icon and enter correct pin -5 consecutive failed pin entry will enable an alarm and the lock will shut down for 3 minutes

Opening the door from the outside (Card, RF Key Tag)


Automatic authentication mode is enabled in default, to switch mode to Automatic/Manual authentication mode please refer to instructions below

Automatic Mode

Place card/key tag on the sensor and the door will open within 1 second

Manual Mode Bee~ree~ ree


When the number pad lights up place the card on the sensor

Touch the number pad

In manual mode, touch the number pad and place card on sensor

Opening/closing the door from the inside


Opening
Bee~ree~ree

Closing
Bee~ree~ree

While the door is closed, Press the [Open] button on the main body and the door will open

In manual lock mode, while the door is closed, press the [Open] button and the door will close

Opening the door manually

Closing the door manually

Turn the manual lever to [Unlock] position

Turn the manual lever to [Lock] position

Pin number Registration


4~12 digits can be registered, only 1 set of pin number can be registered Press [Registration] button Register new pin number Bee~ree~reep

Open battery compartment cover, Press [Registration] button lightly

Enter new pin number to be registered 4~12 digits, then press [*] button

For safety register at least 6 digits pin number (0~9) numbers New pin number registration will delete previously registered pin number on the system Register pin number while door is open

Card, Key Tag Registration


Up to 20 cards can be registered New registration will delete all previously registered pin number on the system Please register all available RF key tags all-at-once Press [Registration] button Place card on sensor
Bee~ree~reep

Open battery compartment cover, Press [Registration] button lightly

Card registration complete

Place card to be registered on the sensor

Bee~ree~reep

To complete the registration process, press the [Registration] button again


Register all available card and key tags all at once. Place the card to be registered on the sensor sequentially within the 10 second time frame or the card registration will complete on its on. Always test authentication of newly registered cards.

Random Number Feature Setting


This feature adds another layer of protection during pin number entry, when enabled will add 2 random numbers together with the original pin upon authentication

Beep~ Beep~

Open battery compartment cover, press pin number

Press [7] button to enable Press [9] to disable followed by [*] button

Double Authentication Mode Setting


This security feature when enabled will require double authentication which is the combination of Pin number and RF card entry. When this is enabled RF card/key tag should be registered

Beep~

Open battery compartment cover, press pin number

Press [4] button to enable Press [6] to disable followed by [*] button

Application Beep~ Beep~

Touch number pad

When the number pad lights up, enter pin number followed by [*] button

Place card on the sensor and the door will open

Automatic/Manual Lock Mode Setting


This setting will change the locking mode to automatic or manual mode

Located in the main body is the [A/M] switch. Place the switch at [A] location for automatic and [M] location for Manual Automatic lock Mode The door will lock within 2 seconds after closing the door Manual Mode - Press the [Open] button inside or touch the number pad outside to lock the door

Sound Setting
Melody guide during pin entry,door closing or opening can be adjusted to desired volume, The melody guide is enabled in default.

Press [registration] button

Set Volume
Bee~ree~ reep

Open battery compartment cover, Press [Registration] button once

Press [0] button to mute Press [1]~[3] button to adjust sound followed by [*] button

Card,Key Tag Automatic/Manual Authentication Mode

Bee~ree~ reep

Open battery compartment cover, Press [Registration] button once

Press [5] button for automatic Press [8] button for manual Followed by [*] button

In automatic Mode place the card on the sensor and the door will open, In manual mode place the number pad and put the card in the sensor to open the door

Automatic Mode is enabled in default, but manual mode consumers lesser battery

Force Lock Settings (Inside)


When enabled will not allow any entry from the outside

Enable
Bee~ree ~ reep

Disable
Bee~ reep

Press [Open] button for 3 seconds

Press [Open] button again

Application

Touching the screen,Entering pin number or placing card on the sensor will not open the door. Turning the manual lever switch to open direction will open the door from the inside

Bee~reep

Force Lock Settings (Outside)


When enabled will not allow opening of the door from the inside, When the [Open] button is pressed inside, an alarm will go be activated.

Enable

Disable

Press the[House] icon for 3 seconds and it is set

Enter pin number followed by [*] button, or place key tag

Replace Battery Notification When the battery is about to be discharge, upon pin or card entry, the replace battery alarm will be heard and the battery lamp will be lighted

Replace Battery
Please replace the battery within a week after hearing the alarm, the lock will shutdown if disregarded.

Battery life depends on brand,usage and environment. Normal battery last for 10 months (based on 10 operations per day) Please check for damage during battery replacement

External Emergency Battery


Disregarding the replace battery alarm for a week will result the battery to being discharged, And the lock to shut down completely.

Opening the door using the emergency battery


Purchase a 9V battery and place the battery accordingly, refer to the image below. In this position enter pin number or place card on sensor to open the door

Security Alarms
Anti-Hacking Alarm This security feature will activate a series of alarm due to multiple failed pin number or card authentication. And the lock will shut down for 3 minutes.

Force Break-in Alarm


This security feature will enable an alarm if the lock senses forceful entry

Fire Emergency Alarm


This security feature will enable an alarm if the lock senses a high temperature of 60 degrees from the inside. A series of alarm will be activated and the door will automatically unlock.