Single-Phase Central Lighting Inverter 1.0 - 17.

5KVA/KW
Features

LSN

AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with any lighting load including incandescent, HID, fluorescent, and LED lamps Painted steel enclosure Offline operation up to 98% efficient Maintenance-free batteries with fully automatic solid state charger Factory startup standard Temperature range: 20C to 30C (68F to 86F) UL 924 listed or 1778 listed; Made in USA

i n v e rt e r s Ordering Information

D
Model D cAPACITY RATING 01 1.0KVA 02 2.0KVA 27 2.7KVA 37 3.7KVA 48 4.8KVA 55 5.5KVA 66 6.6KVA 83 8.3KVA 10 10.0KVA 12 12.5KVA1 15 15.0KVA1 17 17.5KVA2
1

BATTERY RATING S 10-Year Sealed


Lead- Calcium Lead- Calcium Cadmium

G 20-Year Sealed N 25-Year Nickel-

OUTPUT Circuit Breaker Type Blank Normally-On N Normally-Off

OUTPUT Circuit BREAker Voltage Rating A 120VAC B 240VAC C 277VAC D 208VAC OUTPUT Circuit BREAker AMPERE Rating1 15 30 50 20 35 60 25 40 80
1 Normally-Off circuit breakers: a maximum rating of 20 amperes.

OUTPUT Circuit BREAker Quantity1 01 - 20


1

INPUT VOLTAGE 120 120VAC1 208 208VAC 240 240VAC 277 277VAC 347 347VAC
1

Not available on 8.3KVA-17.5KVA Series.

Requires external transformer for 208VAC or 240VAC input. 2 277 and 347VAC input only.

OUTPUT VoltaGE1,2 120 120VAC 240 240VAC 120/208 120/208VAC 120/240 120/240VAC3 120/277 120/277VAC 277 277VAC 347 347VAC
1

Normally-On circuit breakers: a maximum of 14 monitored, single pole positions or 20 unmonitored, single pole positions may be specified. Normally-Off circuit breakers: a maximum of 8 single pole positions (monitored or unmonitored) may be specified.

OUTPUT Circuit BREAker SUPERVISION Blank Monitored U Unmonitored OPTIONS EML Email Device RSP Remote Status Panel SMT System Monitoring
Terminal

EPO Emergency Power Off


Terminal1

Other voltages available. Consult factory. 2 External transformer may be required. 3 Loading may not exceed 50% of the systems total rating on any 120VAC leg.

Bypass Switch (Make Before Break) C10 10 Ampere Charger Upgrade4 C20 20 Ampere Charger Upgrade5 CL60 Cabinet Locks
1 2

AR Alternate Runtime2 SBC Short Battery Cabinet3 IBS Internal Maintenance

*For additional service options, see page 981.

The EPO option requires the SMT option. Specify run time in minutes when ordering. Example: AR120. 3 Available with 1.0, 2.0, 2.7, 3.7, 5.5 and 6.6KVA series with "S" batteries only. 4 Available on 1.0KVA-4.8KVA series. 5 Available on 5.5KVA-17.5KVA series. Not available with 120V input on 6.6KVA and above. Not available with 208V input on 12.5KVA and above. Not available with 240V input on 15.0KVA and above.

Electronics

ACCESSORIES
Model Description

Uninterruptible "no break" transfer Microprocessor controlled pulse width modulation (PWM) using IGBT technology LVD, short-circuit, current limiting, overload and brown-out protection Spectron self-test/self-diagnostic circuitry True sine wave output 40-character user interface with LED indicators and audible alarm system Power factor range of 0.8 lead to 0.75 lag

MBB External Maintenance Bypass Switch (Make Before Break)1 BBM External Maintenance Bypass Switch (Break Before Make)1 DSFK-- Seismic Kit2
1

Supplied in a wall-mounted NEMA 1 type enclosure. Cannot be used in systems with more than one single pole output circuit breaker, on systems with different input and output voltages. 2 See cabinet configurations table to determine proper kit designation.

986

LSN
specifications
KVA/KW Rating 1.0K

Single-Phase Central Lighting Inverter 1.0 - 17.5KVA/KW


2.0K 2.7K 3.7K 4.8K 5.5K 6.6K 8.3K 10.0K 12.5K 15.0K
3

17.5K

Input/Output Voltage Combinations Available Single Phase AC Input Circuit Breaker Rating 120/277V Output Voltage and Maximum Output Current in Amperes Standard Charger Size System DC Voltage Heat Output (BTU/Hr) 120/20A 208/15A 240/15A 277/15A 347/15A 120/8.3 240/4.2 277/3.6 347/2.9 96 175

Input VAC: 120, 208, 240, 277, 347 Output VAC: 120, 240, 277, 347, 120/2401, 120/277 Other voltages available; consult factory2 120/30A 208/20A 240/15A 277/15A 347/15A 120/16.7 240/8.3 277/7.2 347/5.8 96 350 120/40A 208/25A 240/20A 277/20A 347/20A 120/22.5 240/11.3 277/9.7 347/7.8 5 Amps 96 473 120/50A 208/30A 240/25A 277/25A 347/20A 120/30.8 240/15.4 277/13.4 347/10.7 96 648 120/70A 208/40A 240/35A 277/30A 347/25A 120/40.0 240/20.0 277/17.3 347/13.8 96 840 120/70A 208/40A 240/35A 277/30A 347/25A 120/45.8 240/22.9 277/19.9 347/15.9 96 963

Input VAC: 208, 240, 277, 347 Output VAC: 120, 240, 277, 347, 120/2401, 120/277 Other voltages available; consult factory2 120/80A 208/50A 208/70A 240/45A 240/60A 277/40A 277/50A 347/30A 347/50A 120/55.0 120/69.2 240/27.5 240/34.6 277/23.8 277/29.9 347/19.0 347/23.9 10 Amps 96 144 1,155 1,453 208/80A 240/70A 277/60A 347/50A 120/83.3 240/41.7 277/36.1 347/28.8 144 1,750 208/100A 208/125A 240/80A 240/100A 277/70A 277/90A 347/60A 347/80A 120/104.0 120/125 240/52.1 240/62.5 277/45.1 277/54.2 347/36.0 347/43.2 15 Amps 144 144 2,188 2,625 277/100A 347/80A 120/146 240/72.9 277/63.2 347/50.4 144 3,063

i n v e rt e r s

CABINET CONFIGURATIONS FOR 90-MINUTE RUNTIME


KVA/KW Rating 1.0K 2.0K 2.7K 3.7K 4.8K 5.5K 6.6K 8.3K 10.0K 12.5K 15.0K 17.5K

Type S Battery Cabinet Configuration Total Weight (lbs.) Seismic Kit Configuration Type G Battery Cabinet Configuration Total Weight (lbs.) Type N Battery Cabinet Configuration Total Weight (lbs.)

A 838

A 1,116

A 1,122 DSFKA1
4

A 1,222

A 1,492

B 1,926

B 2,130
4

B 2,475

B 2,829
4

B 2,861 DFSKB3
4

C 4,121 DFSKC1 D 4,885 E 5,505

C 4,393
4

DSFKB1 A 1,472 B 1,894 B 1,684 B 2,232 B 2,062 C 2,532

DFSKB2 B B 2,679 D 3,481

A 1,365 B 1,075

A 1,384 B 1,486

A 1,390 B 1,644

B 3,589 D 3,940

D 3,657 E 4,720

D 5,491 Consult Factory

2,630 C 2,812

CABINET CONFIGURATIONS5 ConfigurationA


Depth 18"

Configuration B
Depth 18"

Configuration C
Depth 18"

Configuration D
Depth 18"

Configuration E
Depth 18"

92"

92"

92"

46"

30"
1

60"

60"

90"

90"

On systems with 120/240VAC output, loading may not exceed 50% of the systems total KVA rating on any 120V leg. Loading beyond 50% on any 120V leg will cause an unsafe condition and transformer failure will occur. Call our Service Line at 800-848-6439 for alternate load connection configurations. 2 External Transformer (not illustrated) is required for 12.5K and 15.0K configurations having 208 and 240 input. 3 Input voltage on 17.KVA model limited to 277 and 347VAC only. 4 Available with Type S Batteries; consult factory for alternate runtimes and battery cabinet configurations. 5 Cabinets will be spaced an additional 12" horizontally if using a seismic kit. Transformer cabinet dimendions are 18"W 28"H 15"D and weighs 250 lbs.

987

Service Options
Service Options for Single Phase Inverters

Factory Startup
All single-phase inverter systems (except LiteGear models) are provided standard with factory start-up service by a qualified technician and a two year warranty. A factory trained technician will perform all steps necessary to insure proper operation of the central lighting inverter following installation by a qualified electrical contractor.

Monitoring Program
For additional peace of mind (charge required), an inquiry will be sent to the single-phase inverter system each month and the results will be reviewed by Dual-Lites Technical Support Department. The results of the review will be sent to the designated customer contact with recommendations for corrective action.
S e rv i c e O p t i o n s

Additional Training Visit


After completing the on-site system start-up, the technician will be available at that time to train owner/user personnel. If the appropriate personnel are not available for on-site training at the completion of the factory start-up procedure, an Additional Training Visit (ATV) option is available at extra cost.

Preventive Maintenance Program


All single-phase inverter systems (except LiteGear models) qualify for Dual-Lites preventive maintenance program. This program provides nine different plan levels including extended warranty programs (refer to the below eplaination of plan levels for more information). Each plan offers a choice of preventive maintenance levels that provide annual visits by a factory trained technician plus call for service options.

PMP-A1 Additional 1-year warranty and 1-year service coverage, weekdays, M-F, 8AM to 5PM EST. PMP-B1 Additional 1-year warranty and 1-year service coverage, 24 hours/ day, 7 day/week (no holidays). PMP-C1 Additional 1-year warranty and 1-year service coverage, 24 hours/ day, 7 day/week (includes holidays).

PMP-A2 Additional 2-year warranty and 2-year service coverage, weekdays, M-F, 8AM to 5PM EST. PMP-B2 Additional 2-year warranty and 2-year service coverage, 24 hours/ day, 7 day/week (no holidays). PMP-C2 Additional 2-year warranty and 2-year service coverage, 24 hours/ day, 7 day/week (includes holidays).

PMP-A3 Additional 3-year warranty and 3-year service coverage, weekdays, M-F, 8AM to 5PM EST. PMP-B3 Additional 3-year warranty and 3-year service coverage, 24 hours/ day, 7 day/week (no holidays). PMP-C3 Additional 3-year warranty and 3-year service coverage, 24 hours/ day, 7 day/week (includes holidays).

Service Coverage Includes:


Inspect all battery connections for the presence of corrosion. Clean and retighten all connections to factory specifications Check and recalibrate all input and output parameters and settings Check cooling fans Exercise all circuit breakers Verify the operation of all installed options and remote panels

Run and monitor a system performance check by simulating an input power outage and recording periodic battery readings Clean the inside and outside of all system cabinets Provide a list of any/all items that could possibly prevent the unit from performing its intended function during a power outage and recommend any preventive maintenance actions