Sie sind auf Seite 1von 43

H7GMSW-CS Network Management Software

Users Manual

Beijing Huahuan Electronics Co. Ltd.

Disclaimer
The information contained in this document is subject to change without notice and does not represent a commitment on the part of Beijing Huahuan Electronics Co., Ltd. (Huahuan). The information in this document is believed to be accurate and reliable; however, Huahuan assumes no responsibility or liability for any errors or inaccuracies that may appear in the document. Copyright 2005 Beijing Huahuan Electronics Co., Ltd. All rights reserved. No part of this publication may be reproduced or distributed in any form or by any means, without prior written permission of Huahuan.

Product Name: Manual Version: Last Update:

H7GMSW-CS Network Management Software 1.0 2007. 7

BEIJING HUAHUAN ELECTRONICS Co. LTD. Address: No.26, Shangdi 6th Street, Haidian District, Beijing, 100085 P.R. China Tel: (8610)62981998, (8610)62988820, (8610)62960985 Fax: (8610)82899800 Web: http://www.huahuan.com http://www.huahuan.com.cn E-mail: info@huahuan.com

Index
H7GMSW-CS ....................................................................................................1 Network Management Software ......................................................................1 Chapter 1 Overview ......................................................................................1 1.1 H7GMSW-CS Overview.........................................................................1 1.2 H7GMSW-CS Specification .............................................................2 1.2.1 H7GMSW Network Management Software Has the Following Main Features:.........................................................................................2 1.2.2 Excellent System Structure ............................................................3 1.2.3 Topology Management Function....................................................3 1.2.4 Faulty Management Function.........................................................3 1.2.5 Flexible Security Management Function........................................4 1.2.6 Unified resource administration function.......................................4 1.3 System Deployment ................................................................................4 1.4 Communication Protocol ........................................................................5 1.5 Operation Environment ...........................................................................5 Chapter 2 Software Installation...........................................................................6 2.1 Overview .................................................................................................6 2.2 Preparation before installation ................................................................6 2.3 Installation of software in one PC ...........................................................6 2.4 Installation of independent Server terminal ............................................7 2.5 Installation of independent Client terminal .............................................7 Chapter 3 Interface Description ..........................................................................8 3.1 Main interface .........................................................................................8 3.2 main menu...............................................................................................9 3.2.1 system.............................................................................................9 3.2.2 Topology.......................................................................................20 3.2.3 Network........................................................................................20 3.2.3.1 Menu introduction...........................................................................20 3.2.3.2 SNCP Control..................................................................................21 3.2.3.3 Orderwire Telephone System Setting... ...........................................21 3.2.3.4 Setting of clock and Query... ...........................................................22 3.2.3.5 Error Code Counting and Bit Error Rate (BER) .............................23 3.2.3.6 Set Real Time Clock........................................................................23 3.2.4 Network Element..........................................................................24 3.2.4.1 Card Supervisory Control................................................................25

3.2.4.2 Confirming Current Configuration..................................................26 3.2.4.3 Setting Real Time Clock... ..............................................................26 3.2.4.4 BER test... .......................................................................................27 3.2.4.5 VLAN Configuration... ...................................................................28 3.2.4.6 SDH capability alarm threshold ......................................................28 3.2.4.7 User bind... ......................................................................................29 3.2.4.8 Find... ..............................................................................................30 3.2.4.9 Dip Switch Status ............................................................................30 3.2.5 Failure ..........................................................................................31 Clearing Equipment Alarm....................................................................34 3.2.6 Performance .................................................................................35 3.2.7 View .............................................................................................51 3.2.8 Help..............................................................................................53 3.3 Main Toolbar .........................................................................................53 Chapter 4 Operation Guide ...............................................................................54 4.1 Start the syetem .....................................................................................54 4.1.1 Start Server...................................................................................54 4.1.2 Start SuperClient ..........................................................................54 4.1.3 Start Client....................................................................................55 4.2 Close system .........................................................................................55 4.2.1 Close client...................................................................................55 4.2.2 Close server ..................................................................................55 Chapter 5 Security Management .......................................................................57 5.1 Management Authority..........................................................................57 5.2 User Management .................................................................................58 5.3 Login .....................................................................................................58 5.4 Change Password ..................................................................................58 Chapter 6 Topology Management .....................................................................59 6.1 Primary Definition ................................................................................59 6.2 Function Introduction............................................................................60 6.2.1 Establishment of Subnet...............................................................60 6.2.2 Configuration of Services.............................................................63 6.3 Interface View .......................................................................................67 6.3.1 Topology View .............................................................................67 6.3.2 Physical View ...............................................................................67 6.3.3 Customer Index ............................................................................68 Chapter 7 Performance Management ................................................................69

7.1 Error Code Counting and Bit Error Rate (BER) ...................................69 7.2 Performance supervision time...............................................................69 7.3 Performance card enable control...........................................................69 7.4 Performance Information ......................................................................70 7.5 Performance Threshold .........................................................................70 7.6 Ethernet Performance............................................................................70 7.7 Historic Data Analysis...........................................................................70 Chapter 8 Failure Management .........................................................................71 8.1 Primary Conception ..............................................................................71 8.1.1 Definition .....................................................................................71 8.2 Function Description.............................................................................72 8.2.1 Alarm Item Color Management....................................................72 8.2.2 Alarm Level Management ............................................................72 8.2.3 Alarm Sound Management...........................................................73 8.2.4 Set/clear alarm mask ....................................................................74 8.3. Display .................................................................................................74 8.3.1 Equipment Icon Display...............................................................74 8.3.2 Equipment Interface Display........................................................75 8.3.3 Alarm Information Display ..........................................................76 8.3.4 Alarm Prompt Message ................................................................76 8.4 Alarm Information Query......................................................................78 Information list......................................................................................78 Chapter 9 Appendix...........................................................................................79

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Chapter 1 Overview
1.1 H7GMSW-CS Overview H7GMSW network management software is specially designed by our company for management of various transmission equipment and terminal equipment manufactured, including MSTP equipment, SDH transmission equipment, DSL equipment, and PCM terminal equipment etc. Windows graphical interface both in Chinese and English is adopted which is easy to learn and operate, and has clear and straight forward alarm indications. The software is an important tool for daily maintenance and testing of network and equipment. H7GMSW-CS Management system provides below function 1 Topology Management Display network topology structure with graphic mode. Organize and manage various network nodes and connection between them. 2 Faulty Management Collect and manage all network equipments of Beijing Huahuan Electronica Co., Ltd. Alarm information. Provide query, filtrate, stat., transmitting, phonic alarm function. 3 Performance Management Provide SDH performance management function. Through H7GMSW-CS, the user may inquire all interior history register value of the NE. 4 Security Management Support multi administration accounts provide authorized divisional security management function. Detailed system/equipment operation log is convenient to control operation purview. 5 Resource Management Centralized manage network resource information, network clients information and the relative relations between resource and clients. 6 Log Management Completed log management includes system operation log, equipment operation log, and system event performance management function in order to track the
H7GMSW-CS Users Manual
1

Huahuan status and maintain system. More over, H7GMSW-CS management system provides network configuration management and element configuration management.

1.2 H7GMSW-CS Specification At present, management capability of H7GMSW covers a complete set of equipment manufactured by our company, i.e. all our equipment can be managed in a centralized manner under the same environment, so as to save user investment in manpower and material resources as well as management costs. 1.2.1 H7GMSW Network Management Software Has the Following Main Features: l Centralized monitoring at central computer (key station). Two communication interfaces are adopted between key station and monitored equipment: 4-line RS485 interface and TABS communication protocol; Ethernet interface and TCP/IP communication protocol, satisfying Q3 interface protocol requirements; l Hierarchical management mode is adopted, i.e. area>subnet>equipment>unit panel, with clear management levels, straight forward alarms, as well as fast and convenient query. l Monitored equipment form several subnets, each of which is allocated with a definite subnet address and has a node (main station or main equipment) connected to the key station. All subnet and equipment far from the key station can realize cross-network (area) supervision and management through transmission channels or shared monitoring channels. l This software can also be installed on portable computer, so that in any node, it can monitor all equipment of this subnet in some certain monitoring method. l For equipment with self-healing ability, self-healing adopts
H7GMSW-CS Users Manual
2

Huahuan

Beijing Huahuan Electronics Co., Ltd.

distributed control mode, i.e. supervisory control units of each stations equipment cooperate to fulfill self-healing operation of the network without intervention by key station. After preliminary setting, monitored network and equipment can operate independent from key station and user can decide according to his needs whether key station and network management software shall be adopted. l The software program with high density and efficiency has very small requirement of system resources, and it can operate on any Windows WindowsXP Windows2000 WindowsNT) platform. 1.2.2 Excellent System Structure 1 H7GMSW-CS system adopts three layers of distributed system structure data base ----server---- client . 2 Supports SNMP. 3 Supports MySQL. 1.2.3 Topology Management Function 1 Network Topology layout management, e.g. tree, ring, star topology. 2 Set up network topology view by operator. The user can establish topology node and various connections between these nodes through topology management. 3 Prompt search and orientation of managed node according to IP address or the name of node. 4 Provide network topology tree view. 1.2.4 Faulty Management Function 1 Support all models from Beijing Huahuan Electronics Co., Ltd. Alarm reporting. 2 Real time monitoring the status of every node and refurbish view.
H7GMSW-CS Users Manual
3

Huahuan 3 Monitoring network occurred failure currently and real time renew network node faulty status. 4 Reporting completed faulty information and exact faulty orientation. 5 Powerful alarm query function based on various alarm grade, alarm time, alarm fountain. 6 H7GMSW-CS has also provided the multimedia sound warning function. When alarm occurs, user may hear different sounds that are previous defined.

1.2.5 Flexible Security Management Function 1 Decentralized and regional security management can realize authorization for different user to manage different equipments. 2 Monitoring and tracking operators work status through detailed user operation log and system operation log. 1.2.6 Unified resource administration function 1 Provide unified resource information. 2 Provide the customer information administration function. Query and stat. the status of network resource occupied conveniently though establishing relations between network resource and clients. 1.3 System Deployment H7GMSW-CS system adopts three layers of distributed system structure data base ----server---- client. 1 DataBase: It Adopts MySQL data base management system and it is in charge of memory administration information. 2 H7GMSW Server: it performs various system service. Receiving the event reporting, allocation command and data query request. Accomplishing various transaction processing logics and
H7GMSW-CS Users Manual
4

Huahuan

Beijing Huahuan Electronics Co., Ltd.

providing interface for other system. 3. Client GUI submitting service request and display information. Reality adopts two ways to carry out deployment: Distributed deployment way or stand-alone deployment way. By running installation program, above-mentioned two ways of installation and deployment can be realized. 1.4 Communication Protocol H7GMSW adopts two types monitoring method: network interface monitoring and serial port monitoring. Network interface monitoring adopts SNMP protocol or MSDH protocol, while serial port monitoring adopts MSDH protocol or TABS protocol. 1.5 Operation Environment Hardware environment: CPU Intel Pentium 1GHz or above; Memory: above 512 M; Hard disk space: 40 G; Spare RS232 port; 10M/100M network adapter (Ethernet monitoring); CDROM driver, mouse and monitoring lines .etc. Software environment: Windows platform XP.) (Windows 2000, or Windows

H7GMSW-CS Users Manual

Huahuan

Chapter 2 Software Installation


2.1 Overview

After H7GMSW

Beijing Huahuan Electronics released H7MGSW-CS

version. Through H7GMSW-CS installation process H7GMSW-CS system can be deployed completely. This chapter will describe how to set up and deploy H7GMSW-CS. 2.2 Preparation before installation Before installation H7GMSW-CS, please confirm the following items: 1 Before installation H7GMSW-CS, please confirm H7GMSW-CS has not been installed before in your computer. If it has been installed already, please uninstall in advance. 2 Before installation H7GMSW-CS, please confirm MySQL database has not been installed before in your computer. If it has been installed already, please uninstall in advance. 3 If your computer has installed network safety software, e.g. Norton Internet Security, please break off the software during installation process in order to install H7GMSW-CS properly. Please start network security software again after installation. 2.3 Installation of software in one PC

Under this mode, client terminal, server and database are deployed in the same computer. This mode is good for small network and less network nodes. Comparatively, this mode is the most economic method. 1 MySQL software should be installed before the installation of Server. The username of MySQL system is root; the password is root as well. Please choose gbk as language choice and meanwhile create environment variables. 2 During Server installation, we suggest to choose typical installation. If choosing user-defined installation, Server and Client software will install
H7GMSW-CS Users Manual
6

Huahuan
together. 3

Beijing Huahuan Electronics Co., Ltd.

After installation, installation software will set up H7GMSW database

in MySQL database automatically and start initializing. 2.4 Installation of independent Server terminal

MySQL software should be installed before installation Server. The

username of MySQL system is root; the password is root as well. Please choose gbk as language choice and meanwhile create environment variables. 2 3 During installation Server, we suggest to choose typical installation After installation, installation software will set up H7GMSW database and choose to install Server. in MySQL database automatically and start initializing.

2.5 Installation of independent Client terminal

1 2 3

During installation Client, we suggest to choose typical installation , To install Client user needs not install MySQL database software. After Client installation, MySQL database will not create

choose client and close Server.

H7GMSW database.

H7GMSW-CS Users Manual

Beijing Huahuan Electronics Co., Ltd.

Huahuan

Chapter 3 Interface Description

3.1 Main interface

Client adopts multilevel-view management .Each level view shows level of different logic. Interface will appear as shown in Fig. 3.1-1:

Fig. 3.1-1 main interface

Main view includes the following view element: 1 by menu. 2 Tool bar it is at the bottom of the menu bar and provides operation by button. The system has three kinds of tool bars : object tool bar, net element tool bar and warning tool bar. User can control the tool bar according to his own demand. 3 Status bar it is at the bottom of the main window and provides information which contains socket connection, serial port connection, status of receiving and sending and current time etc. 4 Topology view it is at the most left of the main window and it is tree structure. Its layer is system-area-network-equipment. Double clicking the node of different layer, there will be the corresponding view at the right view.
H7GMSW-CS Users Manual
8

Menu bar it is at the top of the main window and provides operation

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Topology tree view and customers resource can cut over mutually. Clients resource provides the operation of client management, the resource of equipment interface and client binding. 5 View there are four layers of view totally. Dblclicking the node of topology tree view at different layer, it will display corresponding view at the right view, such as system view, area view, network view and equipment view. 6 Window there are five kinds of window: information window, warning window, correlative equipment, fiber link and operation log. 3.2 main menu Main menu includes system, topology, network, net element, malfunction, performance, examining and help etc. The following will introduce the menu one by one. 3.2.1 system Use explaining of the every submenu in the main menu as shown in 3.1 Table 3.1 system menu Name of menu Specification Manage TCP/IP connections between Connection settings equipments Ethernet interface and and options console computer Set communication connection mode and Query queue system operating parameters between management Super supervisory control system and monitored client equipment. Query control & Set normal inquiry and relevant option information. Save Save users settings to the file. Database Backup and Backup and recover the information of Recovery database configuration. Change password Modify password of current user. add delete user modify the password Users popedom area popedom. Data dump Data dump and record Exit Exit the NMS Then we will introduce the function of the systems menu in detail.

H7GMSW-CS Users Manual

Beijing Huahuan Electronics Co., Ltd.

Huahuan
3.2.1.1 Super client Only the super client can see this menu, the common user does not have this menu. 3.2.1.1.1 Connection settings and options
Command System _ Super client _ Connection settings and options

This command is used to manage TCP/IP connections between equipment that supports Ethernet interface and key station computer, e.g. network cards and port addresses used. After executing this command, dialog box will come up as shown in Fig. 3.2.1-1. Click "add" button, then dialog box comes up as shown in Fig. 3.2.1-2. "Select all", "Add", "Edit", "Remove", "Enable" and "disable" button can make modification to equipment information in the list. Only after selecting the information in the list, "Add", "Edit", "Remove", "Enable" and "disable, Connect", "Disconnect" button will be in usable status. You can set "auto restore connection interval". If you want to save this "Query before auto resume." setting, click "Apply" button; otherwise click "Close" button, dialog box will be closed and no change will be made to "Query before auto resume. In the dialog box shown in Fig. 3.2.1-2, you can select "network adaptor" in the pull-down list, and fill in the IP address of the monitored equipment. If you want to enable it, ensure that "enable" check box is selected. If you expect that upon startup, the system automatically restores to the correct connection existing when the system is exit last time, please select "Auto restore connection when startup" check box. If you expect that the system automatically re-establish connection when accidental TCP/IP connection interruption is detected, please select "Auto Connect when broken" check box.

H7GMSW-CS Users Manual

10

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Fig. 3.2.1-1

Fig. 3.2.1-2

3.2.1.1.2 Query queue management... Command System Super user end Query queue management This command is used to set communication connection mode and system operating parameters between supervisory control system and monitored equipment. The Query queue management command is used to set supervisory control switch of subnet or equipment (query or not query) and supervisory control mode (local RS485 supervision or remote RS485 supervision) etc. This
H7GMSW-CS Users Manual
11

Beijing Huahuan Electronics Co., Ltd.

Huahuan
command affects polling task arrangement of the system. Query control & option is used to change operating mode of the supervisory control system. After execution of Option->Queue management command, the dialog box as shown below Fig. 3.2.1-3 appears. In this dialog box, the list box lists objects of which polling is required. For transmission network, a subnet is a querying object; while for digital subscriber loop, a node or equipment is a query object. This list box is a standard Windows choice box with expansion style and permits selection of multiple items. Operating mode of this dialog box permits "first select, then operate" mode, i.e. you can select object first and set it later.

Fig. 3.2.1-3 "Query switch" is used to set an object selected as or not as a query object during system arrangement of polling tasks, so as to include it in or exclude it from daily query task queue. Query Channel is used to set connection mode between key station computer and monitored equipment, i.e. Ethernet port, RS231 port or RS485 interface connection. For RS231 port connection, there is only one system polling object, i.e. the first "Query Channel" in query queue is set as query object of "RS232". At this time, even when query channels of many objects are set as "RS232", the system will query only one of them.
H7GMSW-CS Users Manual
12

Huahuan

Beijing Huahuan Electronics Co., Ltd.

For RS485 connection, all objects in query queue which are not set as "RS232" will be included in query task; hence it can be queried by the system. Therefore, when Query Channel is set as "RS232", there is only one query object; while "RS485", there can be more query objects. For "Ethernet", equipments and console are connected through Ethernet ports; therefore once there is a piece of equipment in a certain subnet connected the console, all the equipments in this subnet will have a chance to be queried by the system. "Query channel" is used to specify communication path between query object and key station computer. If query channel of an object is set as "RS232", this object can only be queried when Query Channel is also set as "RS232". If query channel of an object is set as "local 485" or "remote 485", this object can only be queried when Query Channel is set as "RS485". Similarly, if query channel of an object is set as "Ethernet", this object can only be queried when Query Channel is set as "Ethernet" "Remote 485" connection mode refers to the situation where console computer and monitored equipment are not at the same location and there is no direct information transmission path between them (e.g. optic cable or other usable data channel), and supervisory control information of remote equipment must be forwarded by a local equipment (in the same location as the remote equipment) that has direct information path with key station computer, so as to establish information path with key station computer. This information forwarding mode is called "remote 485 connections". At present Huahuan H700, H760 and H900 equipments provide this information forwarding capability, but there are some differences in their ways of implement. H700 and H760 equipments execute forwarding via secondary encapsulation while H900 equipment adopts routing method. In queue management dialog box, "Priority" column specifies query priority of query objects. The larger the value, the higher the priority, and hence more queries made in unit time. Only in the situation shown below, connection mode could be modified successfully:

Fig. 3.2.1-4
H7GMSW-CS Users Manual
13

Beijing Huahuan Electronics Co., Ltd.

Huahuan
Console is connected with SDH equipment, and when monitoring equipment X via "remote 485", SDH2 and X must be connected via 485 data cable, and notifies SDH2 by setting relative command using network management. For example, SDH2 is H9MOLMF and IP address is 192.192.4.1; X is H5DSL-60 series and address is 30.1. Choose Query Channel according to monitored equipment and "Query channel" choose "remote 485". Click "Modify" button, the dialog box appeared as shown in figure below. Input information as below, and click "OK", then return to queue management dialog box, after clicking "Setting" button console could monitor X equipment through "remote 485". 3.2.1.1.3 Query control & option...

Command: System

Super user end Query control & option

This command will cause the following dialog box show in Fig. 3.2.1-5. "Threshold of no response (min.)" specifies no equipment response alarm threshold in minutes. When the system fails to receive equipment reporting information in a specified period of time, connection between this equipment and the system is deemed lost and "no equipment response alarm" will be generated. Value of this threshold is directly related to number of objects managed and interval of normal state query. The more object being managed and the longer the interval, the higher the threshold value is. When the threshold is defined as 0, no such alarm will be generated. "Polling" specifies at what interval (ms) the system will query a management object. The shorter the period is, the worse the system response to user. Beside, long period has adverse effect on timely collection of alarms. This value is usually set at ms level; default value is 2s. "Supervision reporting ringing" specifies that ringing will be initiated each time the system receives an equipment reporting message. "Close/open query" button can close or open normal state query system. Closing of normal state query system will stop collection of equipment alarms and may cause "No equipment response alarm" When the system detects an alarm, if you want an audio alarm, please select "Sound to Alarm" check box; at the same time, you can also specify the audio file to be played (as the figure below). Note: To realize this function, the computer must have a correctly installed sound card and be connected to sound box, which shall be tuned to suitable volume. When the system detects an alarm, if you want to have supervisory control
H7GMSW-CS Users Manual
14

Huahuan

Beijing Huahuan Electronics Co., Ltd.

system window currently in minimized operation automatically opened, please select "Open it when Minimized" check box (as the figure below), otherwise the icon of the minimized supervisory control system will start blinking. When the system detects an alarm, if you want to display supervisory control system window above all other windows, select "Bring to Front" check box (as the figure below). To save modification made, click "OK" button. To cancel, click "Cancel" button.

Fig. 3.2.1-5 3.2.1.1.4 Save settings Command System Super user end Save The settings will be save to the installation path ServerOption\H7GMSW-CS.ini by executing the command.

3.2.1.1.5 Database backup and Restore Command System shows as Fig. 3.2.1-6. Backup Backup the information of the network management settings of the Mysql database to specified directory. Directories could be default directory
H7GMSW-CS Users Manual
15

Super user end database backup and restore

This command is used for system data file backup and recover. The UI

Beijing Huahuan Electronics Co., Ltd.

Huahuan
specified by system or those specified by user . Create a file, and the format of the file is h7bkup-****-****-******.sql, in which * said Year/Month/Day/Hour/ minute/Second. The * said when the file is created. For example h7bkup-2007-0125-110526.sql Restore Restore the settings information of the specified file .sql to the current database. Note: this operation will delete settings information of the current database, and read-in the settings information of the .sql file to the database.

Fig. 3.2.1-6 3.2.1.2 Change Password

Command: System>Modify password

Fig. 3.2.1-7

This command is used to modify password. User can consider periodical modification of the password according to situations. Enter existing password in the "Password" column of the dialog box and then new password in the "New" column (note case of letters). Then enter the new password again in the "OK" column, which shall be consistent with that
H7GMSW-CS Users Manual
16

Huahuan

Beijing Huahuan Electronics Co., Ltd.

entered in the "New" column. Click "OK" to initiate the new password; otherwise click "Cancel" to continue using old password. When no user has logged-in the system, this command is used to modify system control password. Note: Securely remember your password. If network administrator forgets his password, contact system administrator; if the latter forgets his, contact special system administrator (root); if root user forgets his, contact our company.

3.2.1.3 User Management

Command: System->Users For user management, user must have management authority and correctly log into management system (see section 3.3 for method of logging). This command is gray if authority is not high enough or logging is incorrect. After executing this command, user management dialog box pops up as shown as in Fig.3-1.

Fig. 3.2.1-8 Existing users and their properties are listed in user management dialog box. (Note: only users who can be managed by current login user i.e. users with lower authority than login user, are listed.)

Add User

H7GMSW-CS Users Manual

17

Beijing Huahuan Electronics Co., Ltd.

Huahuan

Fig.3.2.1-9

If you want to add new users, click Add button on user management interface, and input new users name and password into user dialog inbox (password and confirmation password shall be consistent and it is case sensitive). Confirm new users authority (SA can add NA and NM, while NA can only add NM), then click OK button after correct input to add a new user, otherwise click Cancel to cancel add operation. Delete User If you want to delete a user, first select this user in the list box and then click "Delete" button. 3.2.1.4 Data dump...

Command: System->data dump...

H7GMSW-CS Users Manual

18

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Fig. 3.2.1-10

1) 2)

There is a tree chart in the left. It shows the datatype which needs to be recorded and stored. Corresponding value of the type in the left will be displayed in the right. a) b) Overflow dump the capacity of the dump data, including current alarm and history alarm. Periodcal dump if the user set periodcal dump, the data will be dumped every certain days. The period can be set the users. If the data reach the threshold but not reach the period limitation, the data will also be recorded. c) Path. The data to be recorded will be stored in the path $server $/Log/AlarmLog for the alarm . That is path for the alarm log. The file type is .txt.

H7GMSW-CS Users Manual

19

Beijing Huahuan Electronics Co., Ltd.

Huahuan
3.2.1.5 Exit

Command System

Exit

After executing this command, this programme in the task manager end and network management interface will exit. 3.2.2 Topology

Fig. 3.2 shows the explaining of the function of each submenu in main menus topology menu. Menu name Add area Delete area Add network Delete network Add equipment Delete equipment Add connection Delete connection Fig. 3.2 Topology menu Function explaining Add an area Delete the area selected Add a network Delete the network selected Add an equipment Delete the equipment selected Add a connection line Delete the connection line selected

Then we will explain the function of each topology menu in detail.

3.2.3 Network 3.2.3.1 Menu introduction

Table. 3.3 shows the function explaining of each network submenu in main menu. Table. 3.3 Network menu Menu name Function explaining SDH service Configuration Configure SDH equipment service SNCP control Configure equipments SNCP service Orderwire Telephone Set and query the telephone number of System Setting Orderwire telephone in the network. Show the clock status of the equipment and Clock setting and Query clock PRI in the network. Lookup the error code number of each node in Query error code number the network. Setting Real Time Clock Query and set the real time clock of each node in
H7GMSW-CS Users Manual
20

Huahuan

Beijing Huahuan Electronics Co., Ltd.


the network.;

3.2.3.2 SNCP Control...

Command Network-> SNCP Control...


Now the fuction is just supported by H9MOLMXS. Other devices will get the following information column:

Fig. 3.2.3-1 Details can be got from the Users Manual of H9MOLMXS. 3.2.3.3 Orderwire Telephone System Setting...

Command Network Telephone system settings... Supervisory control of orderwire phone subsystem of larger scale transmission subnet can be realized, including monitoring of orderwire phone off-hook/on-hook conditions of each node, control of orderwire break-in authority of a node, or set it to hotline telephone that will call automatically at off-hook, so as to control orderwire telephone meeting. Some types of equipment allow software setting and query of telephone number of node orderwire. Supervisory control of subnet orderwire phone subsystem can be realized by command Network-> Telephone System Settings. We introduce use and operation of the GUI below. Select the pull-down list: Network(N)/ Telephone System Settings , then the telephone system setting dialog box related to such network shows up: For a subnet which consists of equipments of H9MOLMF and H9MOLMX types, the dialog box comes up as below:

H7GMSW-CS Users Manual

21

Beijing Huahuan Electronics Co., Ltd.

Huahuan

Fig.3.2.3-2 "Set" button: select certain equipment, and then set its orderwire telephone. "Query" button: select certain equipment, and then query its orderwire telephone. "Set subnet" button: Set the order telephones of all equipments in the subnet. "Query subnet" button: Query order telephones of all equipments in the subnet. Different equipments could not be set to same number, and could not be set to the number currently used by other equipment. 3.2.3.4 Setting of clock and Query...

Command Network

Clock setting and Query...

Normally, the main node is set as main clock while all other nodes will extract this clock. According to different types of equipment, type of clock and contents of setting can differ. If setting requirements are not met or selection if incorrect, H7GMSW-CS-CS will give alarms in a timely manner (user is not permitted to modify gray parts in the dialog box; the reason may be that the equipment does not support such modification or current network configuration is not suitable). Method of operations related to this command is not described here; please refer to equipment manual. Note: Incorrect clock setting may paralyze the whole network or cause abnormal operation. Do not use this command if operator is not completely familiar with network configuration.

H7GMSW-CS Users Manual

22

Huahuan

Beijing Huahuan Electronics Co., Ltd.

3.2.3.5 Error Code Counting and Bit Error Rate (BER) Error code count is the number of accumulated error codes for binary codes in transmission system. Bit error rate (BER) is the error ratio for binary codes in transmission system, which is approximately equal to PE = Ne/N (error code count divided by total code count) 1 Bit error rate is a system parameter to measure the transmission reliability in normal work state. 2 For an actual data transmission system, it could not be say that more lower BER is surely better. User should establish BER requirement according to actual transmission requirement. With a determinate data transmission speed, the BER is lower, then the transmission system equipment is more complex and the cost is much higher. User can query error code count in equipment disk dialog box, as well as executing the following command to query. Command: Network> Query Error Code Counting With Network->Query Error Code Counting command you can check accumulated transmission error codes of each node on a subnet. In case of sporadic error codes in transmission, you can use this command to find source of error codes so as to locate potential hazard or failure such as falling optic power, lowed reception sensitivity and increased transmission loss etc. Select pull-down menu Network (N) Query Error Code Counting , and then the cursor turns to . Move cursor to the network to be monitored in error code, and click left mouse key after the line standing for network connection turning to yellow, then an error code count dialog box for the subnet will appear. The dialog box will different with each other for different equipment. Click left mouse key on "Reset" button to clear accumulated error codes of all nodes on the subnet and reset the counter. "Query" button is used to immediately find out error code count of each node and Query Subnet button is used to query error code count of all equipment in the subnet. "Timed Query" button is used to automatically check error code count on a fixed interval. Please refer to user manual for more error code query of specific equipment. 3.2.3.6 Set Real Time Clock... At present, Set Runtime clock only realizes on H9MOLMX, H9MOLMF series. Use this command to query and set real time clock of equipment. Command Network Set Runtime Clock... This command is executed for a subnet. After executing, a dialog box then
H7GMSW-CS Users Manual
23

Beijing Huahuan Electronics Co., Ltd.

Huahuan
comes up. Show as Fig. 3.2.3-3.

3.2.3-3 "Current time": show the real time according to console; "Set": set current time into equipment clock of the whole subnet; "Query": Query clock time from equipment of the whole subnet and show it in the list. 3.2.4 Network Element

Fig. 3.4 explains the function of each Network Element submenu of the main menu. Fig. 3.4 Network Menu Function explaining Query alarms and configuration on a unit Card Supervisory Control card confirm current system hardware Confirming Current Configuration configuration; Query and configure the real time clock of Setting Real Time Clock network element Set the function of the equipments BER BER test test. Set equipments VLAN configuration VLAN configuration information. Set threshold value of the SDH capability SDH capability alarm threshold alarm. Bind the information between user and User bind equipment interface. lookup Go to the view of the equipment lookup Menu name
24

H7GMSW-CS Users Manual

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Then we introduce the function of each network element menu in detail. 3.2.4.1 Card Supervisory Control... Command Control Network Element (NE) Unit Card Supervisory

Fig. 3.2.4-1 This command is used to query alarms on a card of target Network Element and can initiate relevant test function. After execution this command, cursor changes to , click left mouse key on the card of target equipment to view various alarms associated with this disk. To cancel this operation, press "Esc". Most contents of network element level supervisory control are centralized on card of network element. Each card corresponds to a dialog box that manages information associated with this disk. Shortcut: double click left mouse key on the card of target equipment.
H7GMSW-CS Users Manual
25

Beijing Huahuan Electronics Co., Ltd.

Huahuan

3.2.4.2 Confirming Current Configuration Command: Network Element(NE) Confirm current configuration This command is used to confirm current system hardware configuration, i.e. that current equipment configuration is correct. After execution of this command, the supervisory control system will record idle cards in equipment as normal without giving alarm; at the same time, cards not detected by the system will be deleted from equipment view (deletion of a card will shield all alarms on such disk) and no more displayed, so as to maintain consistency of H7GMSW-CS-CS user interface with physical network and equipment. If you want to restore display of card s deleted from equipment view, first clear all alarms on equipment and then execute this command once more. After execution of this command, enter equipment selection stage. Click left mouse key on destination equipment; press "Esc" to cancel this operation. 3.2.4.3 Setting Real Time Clock... Command Network Element(NE) Set runtime clock... This command is executed for a subnet. After executing, a dialog box then comes up. Show as Fig. 3.2.4-2.

Fig. 3.2.4-2 "Current time": show the real time according to console; "Set": set current time into equipment clock; "Query": Query clock time from equipment and show it in the list.

H7GMSW-CS Users Manual

26

Huahuan
3.2.4.4 BER test...

Beijing Huahuan Electronics Co., Ltd.

Commangd Network Element(NE) ->BER testing... Currently only H9MOLMA, H9MOLMXS support this function and other equipments can not support. For H9MOLMA, BER test is usable only when distributing the services, the cross connection between mistake code instrument and E1 or optical port is established. BER test is usable not required to set the services of H9MOLMXS equipment. For H9MOLMA equipment, before BER testing, the step of setting service is as below: 1 2 Executenetwork configuration- SDH services configurationmenu item open SDH service configuration dialog box; Clicknewbutton. For services type, select unprotected in the open dialog box. Then select the card directory and time slot for one card directory in that, select E1 BER test 3 4 click Add Exit the dialog box of service configuration, then click download. And the service configuration is finished. Clickupload button. Query service from equipment, and validate whether the service is configured successfully. After executing this command, a dialog box then comes up, show as Fig. 3.2.4-3. It shows the records of BER testing information:

Fig. 3.2.4-3

H7GMSW-CS Users Manual

27

Beijing Huahuan Electronics Co., Ltd.

Huahuan
3.2.4.5 VLAN Configuration... Command Network Element(NE) VLAN configuration VLAN...

Currently only H9MOLMA supports this function. Only in H9MOLMAs equipment view, this menu item is usable status, otherwise, it is gray with unusable status. 3.2.4.6 SDH capability alarm threshold Command Network Element(NE) SDH SDH capability alarm threshold

After executing this command, a dialog box then comes up, shown as Fig. 3.2.4-4. Once the SDH capability threshold is set, the alarm is reported only when the capability mistake code exceeds the threshold value. Alarm is displayed in the dialog box of the equipment. Series Display equipments IP address Threshold range Display the set value area of the SDH capability alarm threshold; Value query Display SDH capability alarm threshold value queried from the network element; Value set This control can be edited, an can modify the setting value, but the value modified must be in the area of the threshold value; Query Query SDH capability alarm threshold value from network element, and display in the Query value list. Set Set the modified threshold value in the list to the network element.

H7GMSW-CS Users Manual

28

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Fig. 3.2.4-4 3.2.4.7 User bind...

Command NE->User Bind


Executing this command will bring out a window showing the devices name, card number, card type, interface type, interface number and users name. Select the users name for the pulling menu and then user can bind the info of the system and the user by clicking on button bind.

H7GMSW-CS Users Manual

29

Beijing Huahuan Electronics Co., Ltd.

Huahuan

Fig. 3.2.4-5 3.2.4.8 Find... Command NE->Find Click the button position , the view will switch to equipment icon.

Fig. 3.2.4-6 3.2.4.9 Dip Switch Status Command: NE->Dip Status This command is used to query equipment dips status. Click this menu, move mouse to the equipment icon, click left key, the sytem will open the Dip Status dialog, click Query button, you can get the equipment dip status.

H7GMSW-CS Users Manual

30

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Fig. 3.2.4-7

Note Now the fuction is only supported by LMV series including H9MOLMV H9MOLMC H9MOLM63 H10MOC240 H10MOC480 H9MOLMN H9MOLMNE H9MOLMN4E1 H9MOLMNFE. 3.2.5 Failure 3.2.5.1 Browse current alarm...

Command Failure-> Browse current alarm... Current Alarm the alarm which has happened but hasnt been confirmed, or the alarm which has been confirmed but still exist Historical Alarm the closed alarm that has been confirmed or the confirmed alarm that has closed. That is, the alarm which has both closed time and confirm time. You will see the following window of the alarm information.
H7GMSW-CS Users Manual
31

Beijing Huahuan Electronics Co., Ltd.

Huahuan

Fig 3.2.5-1 Alarm Status Include current alarm and historical alarm

Alarm Level Include urgent alarm, major alarm, minor alarm and warning alarm. Select the alarm level and click Query, all the alarms of this level will be displayed. Query Range The alarm of different equipment ,different network and different area can be checked seperately. If the Total Area is selected, the alarm of all the areas will be displayed. If not, user can select the area, subnet and equipment in which the alarm occurs. Begin Time If the SetEnabled is selected, the begin time range of the alarm can be modified; if not, the begin time range is fixed. End Time If the SetEnabled is selected, the end time range of the alarm can be modified; if not, the end time range is fixed. Query The window will display all the information of the alarm according to the alarm status, alarm level, query range, begin time, end time. The total number of the alarms can be got at the bottom.
32

H7GMSW-CS Users Manual

Huahuan
Select All

Beijing Huahuan Electronics Co., Ltd.


select all the information in the list

Confirm confirm the information in the list. The command will update the Confirm Alarm list. E.g. root--2007-07-09 10 57 01 root is the users name and 2007-07-09 10 57 01 is the confirm time. Print print out the information in the list Close close the dialog box Click right mouse key on the item in the list will bring a menu. User can select to check the equipment or card the alarm occurs to . Note If the alarms still exist, the alarm will display the color of corresponding alarm level. 3.2.5.2 Browse Historical Alarm ...

Command Failure-> Browse historical alarm... After executing the command, user will see a dialog box as fig 3.2.5-3. The operation details of this dialog box can be referred to 3.2.5.3 browse historical alarm... 3.2.5.3 Set and clear alarm mask When an alarm occurs, equipment will initiate top-of-cabinet audio/video alarm while the supervisory control system will display the alarm on screen in set mode. H7GMSW provides the function to set alarm mask to screen known and unnecessary alarms. Setting of alarm mask has two meanings. First is the alarm mask in equipment. When this is set, current operating status of equipment will be regarded as normal status and all alarm items will be screened so that top-of-cabinet audio/video alarm will not be initiated, which will be initiated only when an alarm other than existing alarm items occurs. Setting of equipment alarm mask will not affect reporting of equipment alarm items to the key station. Second, when setting alarm mask, supervisory control system will also set alarm mask in key station database. After that, screened alarm items will no longer cause flashing alarm of station label, functional disk or alarm sign, but will be displayed in normal status on user interface. The characteristic feature is that these screened alarm items will no longer flash; but unscreened new alarm will still follow set alarm mode. Command: Equipment->Set alarm mask

H7GMSW-CS Users Manual

33

Beijing Huahuan Electronics Co., Ltd.

Huahuan
This command is used to set alarm mask for equipment to screen .

useless alarms. After execution of this command, mouse cursor will turn to

Move cursor to the equipment to be set with alarm mask, then click left mouse key on it. A hint box will appear to show whether the setting is successful or not. Command: Equipment->Clear alarm mask This command is used to clear equipment alarm mask set in key station database and to restore normal display of screened alarms on key station. But this command is not effective to physical equipment to avoid top-of-cabinet audio/video alarm in remote equipment room after key station carries out this operation, which will put personnel on duty in false alarm. Change of physical equipment alarm mask can only be realized by setting alarm mask again after eliminating alarm items. For instance, when current idle 2M port is put into operation, alarm mask should be set again so that when signal of this 2M interface is lost, it will give correct alarm. Method to use this command is the same as that for setting alarm mask. Clearing Equipment Alarm

Command: Advanced>Clearing equipment alarm>All area All equipment alarms in all area will be cleared after execution of this command. Command: Advanced>Clearing equipment alarm>Active area All equipment alarms in current active area will be cleared after execution of this command. Command: Advanced>Clearing equipment alarm>Specific subnet All equipment alarms in all specific subnet will be cleared after execution of this command. Command: Advanced>Clearing equipment alarm>Specific equipment Specific equipment alarms will be cleared after execution of this command.

3.2.5.4 Synchronize Alarm

Command: Failure> Synchronize Alarm


H7GMSW-CS Users Manual
34

Huahuan

Beijing Huahuan Electronics Co., Ltd.

After executing the command, the equipment will report all the alarms. Now command only supports H9MOLMX H9MOLMF H9MOLMXS. 3.2.5.5 Alarm Icon Glitter Command: Failure-> Alarm Icon Glitter The command will decide whether the icon of the equipment ,network a nd area will blink or not when alarm occurs. 3.2.5.6 Show power alarm light Command: Failure-> Show power alarm light Users can set the alarm light indication by this command. When alarm occurs, the power alarm will display in different colours. Red: urgent alarm , orange: main alarm e.g.

3.2.5.7 Show alarm color when mask Command: Failure-> Show alarm color when mask When the alarm is masked, all the icons will display the colour of the highest level using this command. 3.2.6 Performance 3.2.6.1 Browse... Command: Performance-> Browse... The command is used to check the performance of the unit card, but before the query, user needs to set the supervision time. Equipment Card display the IP address of the network element

display the unit card name and slot

Type display all the registers type and number Supervision cycle 15 mins or 24 mins registers supported, Default :15 mins
H7GMSW-CS Users Manual
35

Beijing Huahuan Electronics Co., Ltd.

Huahuan
ES error code block second the second in which one error code or more occur SES severe error code second error code block occur UAS unavailable section start after 10 sequential SES , and the UAS includes the 10 seconds BBE background block error 1. current register error occurs except UAS and SES time the second in which more than 30%

Fig. 3.2.6-1 Begin time display the begin time of current register Query send the query command to the network element according to card type , register type , register number, watch tim (15 mins, 24 hours) 2. history register

H7GMSW-CS Users Manual

36

Huahuan

Beijing Huahuan Electronics Co., Ltd.

Fig. 3.2.6-2 Begin time display the begin time of current register Watch Period If user selects to query from network element, the watch period is grey. It is available if user selects to query from the network management software. Query If user selects to query the network element, query commands will be sent to the histoty register according to card type, register type , register number, register watch time. If user selects to query from the NMS, items compliant with the query condition will be displayed in the list. 3. Unavailable time

H7GMSW-CS Users Manual

37