Sealed Lead-Acid Battery

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20567.

UPG No. D5740

UB1234
Maintenance-Free

Specication
Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (0.171A) 3.4AH 10-hr. (0.316A) 3.16 Ah 5-hr. (0.58A) 2.9 Ah 1-hr. (2A) 2 Ah Approximate Weight 3.02 lbs (1.37 kgs) Internal Resistance (approx.) 37m Shelf Life (% of normal capacity at 77 F (25 C)) 3 Months 6 Months 12 Months 91% 82% 64% Temperature Dependancy of Capacity (20 hour rate) 104 F 77 F 32 F 5 F 102% 100% 85% 65% AGM Operational Temperature Charge 0 C to 40 C Discharge -15 C to 45 C AGM Storage Temperature -15 C to 40 C

Charge Method (Constant Voltage) Cycle Use (Repeating Use) Initial Current 1A max. Control Voltage 14.5v - 14.9v Float Use Control Voltage 13.6v - 13.8v

Physical Dimensions: in (mm)


5.30 (134.5)

Terminals
L: 5.3in (134.5 mm) W: 2.64in (67 mm) H: 2.42in (62 mm) TH: 2.63in (66.8 mm) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice.
2.42 (62) 2.64 (67) 2.63 (67)

Discharge Time vs. Discharge Current

Discharge Characteristics

Cell voltage (V/Cell)

(Minute) Discharge time

(Hour)

www.upgi.com
1720 Hayden Drive Carrollton, Texas 75006 P 469.892.1122 T 866.892.1122

All specifications subject to change.

F 469.892.1123

sales@upgi.com
L1226-1

UPG No. D5740

UB1234
Maintenance-Free

Battery Charging Characteristics for Cyclic Use

Battery Charging Characteristics for Standby Use

Cell charge voltage


Cell charge voltage ( V/Cell )

Cell charge voltage


Cell charge voltage ( V/Cell )

Charge current (CA)

Charge volume (%)

Charge volume (%)

1 Discharge 100 % (0.1CA*10h) -- 50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.45V/cell Charge current : 0.3CA 3 Temperature : 25 (77 )

Charge current (CA)

Charge volume

Charge volume

1 Discharge 100 % (0.1CA*10h) --50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.275V/cell Charge current : 0.1CA (77 ) 3 Temperature : 25

Charge current

Charge current
Charge Time (hr)

Charge Time (hr)

Shelf Life & Storage

Cycle Life vs Depth of Discharge

Open Circuit Voltage vs Residual Capacity

Effect of Temperature on Capacity

Charge Current & Final Discharge Voltage


Application Cycle Use Standby Charge Voltage(V/Cell) Temperature 25 (77 ) 25 (77 ) Set Point 2.45 2.325 Allowable Range 2.40~2.50 2.30~2.35 Max.Charge Current 0.30C

Final Discharge Voltage V/Cell Discharge Current(A)

1.75 0.2C>(A)

1.70 0.2C<(A)<0.5C

1.60 0.5C<(A)<1.0C

1.30 (A)>1.0C

Let UPG Power Your Life.