Quick Card
Voluson 730 Expert
1 New Patient Key 2 Probe / Program Key 3 Report Key 4 Touch Screen 5 TGC Controls
10
7 M Mode & Gain Control / Y Axis* 8 PD Mode & Gain Control / Z Axis* 9 CFM Mode & Gain Control / Parallel Shift* 2D Mode & Gain Control 3D & 4D Key Measurement Key Calculation Key
14 15 16 17 18 19
Trackball & Trackball Keys HD Zoom Harmonics On/Off Depth Freeze / Run Key Touch Screen Rotary & Toggle Flip Switch Controls ABC - Annotation Print Keys
11 12 13
20 21
*3D Control
GE Healthcare
Entering Patient Data 1. Press the New Patient Key [1]. 2. Enter Patient Name and Patient ID. If no LMP, EDD or GA is typed in, no information in the Growth Chart will be displayed. 3. Select Start Exam. Probe/Program Selection 1. Press the Probe/Program Key [2]. 2. Probes are displayed on Touch Screen [4], select Probe. 3. Select Application and Setting on the Touch Screen. Generic Measurements 1. Press the Measurement Key [12]. 2. Select the measurement on the Touch Screen. 3. For distance measurement press Generic Dist. 4. To set the caliper press the Left or Right Trackball Key [14]. Calculation Measurements 1. Press the Calc Key [13]. 2. Select the measurement from the Touch Screen [4]. 3. The calipers can be set by Left or Right Trackball Key [14]. 4. For Patient Report press Report Key[3].
CFM Mode (Color Flow Mapping Mode) 1. Press CFM Mode Key [9]. 2. Color box appears, this box can be moved with Trackball [14]. 3. For adjusting size of box press Upper Trackball Key [14]. 4. Adjust size with Trackball, press Upper Trackball Key [14] again for moving box. PW Mode (Pulsed Wave Doppler Mode) 1. Press PW Mode Key [6]. 2. Doppler gate can be moved with the Trackball. 3. For changing gate size press Upper Trackball Key [14], move Trackball. 4. Press Upper Trackball Key [14] again for fixing gate size. 5. Press Left Trackball Key [14] for activating Doppler. 6. If Duplex is desired press Right Trackball Key [14]. 3D/4D Mode 1. Press the 3D & 4D Key [11]. 2. Choose the appropriate application on the Touch Screen. The Right Trackball Key [14] or Freeze Key [18] will begin the acquisition. NOTE: If PW/CFM is active press the PW Mode Key [6] to go back to CFM and vice versa. To deactivate all modes press the 2D Mode Key [10]. Same procedure for PW / PD Mode. IMPORTANT NOTE: An Electronic User Manual [EUM] is integrated on the Voluson 730 Expert. Press the [F1] Key on the keyboard to activate the electronic user manual.