Quick Card
Voluson 730 Expert
1 New Patient Key 2 Probe / Program Key 3 Report Key 4 Touch Screen 5 TGC Controls
10

7 M Mode & Gain Control / Y Axis* 8 PD Mode & Gain Control / Z Axis* 9 CFM Mode & Gain Control / Parallel Shift* 2D Mode & Gain Control 3D & 4D Key Measurement Key Calculation Key

14 15 16 17 18 19

Trackball & Trackball Keys HD Zoom Harmonics On/Off Depth Freeze / Run Key Touch Screen Rotary & Toggle Flip Switch Controls ABC - Annotation Print Keys

6 PW Mode & Gain Control / X Axis*

11 12 13

20 21

*3D Control

GE Healthcare

Entering Patient Data 1. Press the New Patient Key [1]. 2. Enter Patient Name and Patient ID. If no LMP, EDD or GA is typed in, no information in the Growth Chart will be displayed. 3. Select Start Exam. Probe/Program Selection 1. Press the Probe/Program Key [2]. 2. Probes are displayed on Touch Screen [4], select Probe. 3. Select Application and Setting on the Touch Screen. Generic Measurements 1. Press the Measurement Key [12]. 2. Select the measurement on the Touch Screen. 3. For distance measurement press Generic Dist. 4. To set the caliper press the Left or Right Trackball Key [14]. Calculation Measurements 1. Press the Calc Key [13]. 2. Select the measurement from the Touch Screen [4]. 3. The calipers can be set by Left or Right Trackball Key [14]. 4. For Patient Report press Report Key[3].

CFM Mode (Color Flow Mapping Mode) 1. Press CFM Mode Key [9]. 2. Color box appears, this box can be moved with Trackball [14]. 3. For adjusting size of box press Upper Trackball Key [14]. 4. Adjust size with Trackball, press Upper Trackball Key [14] again for moving box. PW Mode (Pulsed Wave Doppler Mode) 1. Press PW Mode Key [6]. 2. Doppler gate can be moved with the Trackball. 3. For changing gate size press Upper Trackball Key [14], move Trackball. 4. Press Upper Trackball Key [14] again for fixing gate size. 5. Press Left Trackball Key [14] for activating Doppler. 6. If Duplex is desired press Right Trackball Key [14]. 3D/4D Mode 1. Press the 3D & 4D Key [11]. 2. Choose the appropriate application on the Touch Screen. The Right Trackball Key [14] or Freeze Key [18] will begin the acquisition. NOTE: If PW/CFM is active press the PW Mode Key [6] to go back to CFM and vice versa. To deactivate all modes press the 2D Mode Key [10]. Same procedure for PW / PD Mode. IMPORTANT NOTE: An Electronic User Manual [EUM] is integrated on the Voluson 730 Expert. Press the [F1] Key on the keyboard to activate the electronic user manual.

GE Healthcare 9900 Innovation Drive Wauwatosa, WI 53226 U.S.A. 888-202-5528 www.gehealthcare.com


2008 General Electric Company All rights reserved. GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, a General Electric company, doing business as GE Healthcare. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE representative for the most current information. GE, GE Monogram and Voluson are trademarks of General Electric Company.