CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION

OFFICE OF THE STATE FIRE MARSHAL


FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

LISTING SERVICE
LISTING No. 7170-0026:187 Page 1 of 2

CATEGORY: Control Unit (High-Rise)

LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001


Contact: Paul Mattern (978) 731-8542 *Fax (978) 731-8881

DESIGN: Models 4100-8001, 4100-8201, 4120-8001 and 4120-8201. Power-limited, coded,


non-coded or marchtime local, local with shunt master, auxiliary, remote station, central
station and proprietary (protected premises). Automatic, manual and waterflow alarm
service. Suitable for sprinkler supervisory service as a local or proprietary system.
Suitable for releasing device service. The basic system consists of a Model 4100-7003 or
4100-7023. The Models 4100-8001 and 4120-8001 are suitable for combustible gas
monitoring.

Models 4100-8511, 4100-8601, 4100-8602, 4120-8511, 4120-8601 and 4120-8602 Universal


Transponders are suitable for coded, noncoded or march time local, central station and
proprietary protected premises service. Automatic, manual, waterflow and sprinkler supervisory
service. Suitable for releasing device service. The basic system consists of a Model 4100-7501
or 4100-7502.

Models 4100-8010, 4100-8019, 4100-8210, 4120-8010, 4120-8019 and 4120-8210 miniplex


control units are suitable for coded, noncoded or march time local, local with shunt master box,
auxilliary, remote station protected premises, proprietary protected premises and receiving
service, central station protected premises service. Automatic, manual, waterflow alarm;
suitable for sprinkler supervisory service as a local, proprietary or central station system.
Suitable for releasing device service. The basic system for the -8010 and -8210 numbers
consists of a Model 4100-7003 or 4100-7023. The Models 4100-8001 and 4120-8001 are
suitable for combustible gas monitoring.

Models 4120-8801 and 4120-8821 are suitable for display and control of other 4020 and 4120
series control units which are connected together to form a network.

4100-2002, -2003 Enclosure


4100-7003, -7023, -7501, -7502 Master Control Module
2190-9093 Syntest Remote Printer
2081-9031 Sprinkler Supervisory Resistor
4100-5001, -5004, -5011, -5014 Initiating Zone Module
4100-4001, -4011, -4321, -4331 Indicating Circuit Module
4100-4201 through 4100-4206 Speaker Circuit Module
4100-0102, -0103 Amp/Volt Meter
4100-0104, -0124 Battery Charger
4100-0105, -0115, 0108, -0118 Power Supply
-1108, -0117, -0119, -0127, -0136
4100-106 Regulated Power Option
4120-6011, -6012, -6014, -6023 Network Module
-6024, -0142, -0143, -0144

*Rev. 05-12-2003
Listing No. 7170-0026:187
Page 2 of 2

4100-0153, -0155 DACT


4100-0122 Remote Interface Card
4100-0304 Remote Unit Interface
4100-0303 Remote Annunciator Interface
4100-0301 LED/Switch Controller
4100-0302 Graphic Interface
4100-0401 through -0405, Color LED
-0408, -0417
4100-0412 through -0416 Speaker Select LED
4100-6001, -6002 Master Controller
4100-8009, -8209 Remote Annunciator Panel
4100-3001, -3002, -3003 Relay
4100-0110, -0111, -0113 Interface Module
4100-0123, -0137 Style 7 Interface Module
4100-0210, -0211, -0212 Audio Channel
4100-0201, -0202, -0203 Amplifier
-0207, -0213, -0217, -1203, -1207
4100-0204 Microphone and Enclosure
4100-0205 Master Telephone
4100-0206 Redundant Tone Generator
4100-0220 through -0223 Message Set
4100-0410 Remote Microphone and Enclosure
4100-411 Remote Master Telephone
4100-0450 Remote Display
4100-0451 Panel-mounted Printer
4100-316 Decoder Module
2081-9046 Coil Supervision Module

INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.

MARKING: Listee's name, model designation, and UL label.

APPROVAL: Listed as a fire alarm control unit for use in high-rise structures when used with separately
listed initiating and indicating devices.

This control unit does not generate a temporal pattern signal. If the distinctive three-pulse
Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with
NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can
generate the temporal pattern signal. Refer to manufacturer’s Installation Manual for
details.

This control unit meets the requirements of UL-864, 8th Edition Standard.

*Rev. 05-12-2003

This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee’s data sheet, installation instructions and/or other suitable information sources.

Date Issued: JUNE 3, 2008 Listing Expires June 30, 2009