Hitec Power Protection Diesel Rotary UPS systems

www.hitec-ups.com
Ride through systems Diesel UPS systems

Hitec Power Protection


What we do

The problems
1. Spikes 2. Frequency Variations 3. Voltage Sags 4. Outages 5. Harmonic Distortions 6. Transients

The solution

The result
7. Continuous Quality Power

Major components
Generator Diesel engine

Choke coil

Switchgear

Dicon

Induction coupling

Freewheel clutch Control panel

Free inner rotor principle

AC machine Induction coupling Freewheel clutch Diesel engine

Four basic principles (1)


Simple, sure and reliable
Rotary UPS/CPS concept invented and patented by Hitec Power Protection in 1969 Rotary UPS/CPS = static UPS + standby generator Fewer components than static UPS Smaller footprint than static UPS Easy installation & operation Long lifespan (>25 years)

Line-interactive system
Rotary UPS/CPS run in parallel with utility power Life-guarding mission critical processes No power conversion

Four basic principles (2)


Active filter (choke coil + generator)
Compensation utility voltage deviations Filtering of utility borne harmonic voltages Filtering of load borne harmonic currents Power factor improvement (>0.98)

Environmental friendly system


Most energy efficient UPS/CPS system Use of stored kinetic energy No batteries required, no chemical waste No conditioned battery room required, saving space and energy for ventilation and cooling Lowest Total Cost of Ownership (TCO)

Diesel Rotary UPS system


Specifications
Diesel, UPS and energy storage combined Lowest TCO, 25+ years productive lifetime No power conversion High end-to-end efficiency (>96%) High output values Single unit rating Up to 2,5 MVA Parallel configuration rating Up to 40 MVA Output voltage LV 380 .. 480 V, 50/60 Hz MV Up to 24 kV, 50/60 HZ Voltage deviation +/- 1% Frequency deviation +/- 1% Options (e.g. remote monitoring, containerized designs, vibration monitoring, .)

All in one

Standby Diesel

Hitec DRUPS

Static UPS
PFC Standby Batteries Busduct & Cabling Fire Protection & Security

Air Conditioning UPS Inverters

Spark-proof Lighting

Lowest TCO
Total losses <3% 100%
Benefits Hitec Power Protection systems: - Energy efficiency (no power conversion) >96% - Reliability (fewer elements) - Space efficiency (zero footprint) - Lowest maintenance - Environmental friendly (no batteries) - Lifespan system (>25 years)

Hitec Rotary UPS

Static UPS System


100%

Total losses >8%


Fire Protection & Security

<92%

Air Conditioning Standby Batteries

UPS Inverters

PFC

Busduct & Cabling

Spark-proof Lighting

It is in the windings
Outer Rotor 2 pole AC windings 2 pole DC windings
50 Hz 1500 RPM 60Hz 1800 RPM

Inner Rotor Stored Energy


50 Hz 1500 3000 + 4500 RPM 60Hz 1800 3600 + 5400 RPM

System operation

Dependent system load


3n Speed (rpm) n 0

Time

Utility mode

3n Speed (rpm) n 0

Time
Q3

Reactor and generator function as active filter. The induction coupling stores kinetic energy.

Q1

Q2

Change-over to diesel mode

3n Speed (rpm) n 0

Time
Q3

Power problem - Q1 opens, energy from the inner rotor goes via the generator to the load. The diesel engine starts up and takes over the power supply.

Q1

Q2

Diesel mode

3n Speed (rpm) n 0

Time
Q3

The outer rotor of the induction coupling is re-energized. The speed of the diesel engine is digitally controlled ensuring a constant output

Q1

Q2

Back to utility mode

3n Speed (rpm) n 0

Time
Q3

Utility power is back and after it has stabilized the UPS/CPS synchronizes and closes Q1. The diesel engine ramps down and the free-wheel clutch disengages.

Q1

Q2

Recording mains failure


Dynamic UPS at 100% load
Moment of mains failure Mains voltage Mains Voltage

Diesel engine RPM 1500 rpm Free wheel clutch engaging

Output voltage

50.5 Hz 50 Hz 49.5 Hz 1 sec. Diesel start

50 Hz Line

Output frequency [Hz]

Technical features D-UPS


Uses stored kinetic energy 50/60 Hz technology Integrated power factor correction Effective filter for spikes & harmonic distortion High non-linear load capacity High peak current capability (typical 15 In) Very efficient with low operational costs Easily paralleled MV applications up to 40 MVA

Hitec D-UPS configurations

Unit configurations Single output Dual output Medium Voltage

System configurations Parallel redundant Master slave Cross link Isolated redundant Distributed redundant