ATEX Certified Pt100 sensors

LEX15A Explosion Proof Resistance Thermometer EEx e for zone 1 and 2


II 2 G EEx e II T6 certified. According EN50014 and EN50019 Designed to measure temperatures in explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Thermowell connection by a 1/2"NPT nipple union nipple. Aluminium connection head DAN-AK with swing cover. Stainless steel connection head optional. Cable entry M20x1.5mm. Replaceable 6mm springloaded insert. Sensor Pt100 2, 3 or 4 wire system. Accuracy to IEC 751 class A, B or better. Single or duplex. Can be delivered with head mounted transmitter. Insertion length as required. Ordering code Type LEX15A

LEX15B Explosion Proof Resistance Thermometer Eex e for zone 1 and 2


II 2 G EEx e II T6 certified. According EN50014 and EN50019 Designed to measure temperatures in explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Thermowell connection by a 1/2"NPT nipple union nipple. Aluminium connection head model CE with threaded cover. Stainless steel connection head optional. Cable entry M20x1.5mm. Replaceable 6mm springloaded insert. Sensor Pt100 2, 3 or 4 wire system. Accuracy to IEC 751 class A, B or better. Single or duplex. Can be delivered with head mounted transmitter. Insertion length as required Ordering code Type LEX15B

LEX15C Explosion Proof Resistance Thermometer EEx e for zone 1 and 2


II 2 G EEx e II T6 certified According EN50014 and EN50019 Designed to measure temperatures in industrial explosive environments with gaseous or liquid. Temperature sensor range: -200C to 550C. Sensor Pt100 2, 3 or 4 wire system. Single or duplex. Accuracy to IEC 751 class A, B or better. Direct connected PVC, PE or PTFE cable with screen and drainwire. Optional: armoured cable. Epoxy filled pot seal IP65 rated. Sensor diameter to be specified. Length as required. Process connection by an optional compression gland or feedthrough Ordering code Type LEX15C

LEX15 Pt100 Thermometer EEx e with Integrated 2-Wire Transmitter


II 2 G EEx e II T6 for zone 1 & 2. According EN50014 and EN50019 Transmitter integrated, model and range to be specified. Designed to measure temperatures in explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Replaceable springloaded 6mm insert. Accuracy to IEC 751 class B Thermowell connection by a 1/2"NPT nipple union nipple. Aluminium connection head DAN-AK with swing cover. Stainless steel connection head optional. Cable entry M20x1.5mm. Insertion length as required. Ordering code Type LEX15

Weteringweg 10 2641 KM Pijnacker The Netherlands

Phone +31 (0)15 - 3621200 Fax +31 (0)15 - 3694082 Email sales@thermo.nl Internet http://www.thermo-electra.com

ATEX Certified Pt100 sensors

LEX25A Explosion Proof Resistance Thermometer EExi for zone 0,1 and 2
II 1 G EEx ia IIC T4..T6 certified. According EN50014, EN50020 and EN50284 Designed to measure temperatures in explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Thermowell connection by a 1/2"NPT nipple union nipple. Aluminium connection head DAN-AK with swing cover. Stainless steel connection head optional. Cable entry M20x1.5mm. Replaceable springloaded 6mm measuring insert. Sensor Pt100 2, 3 or 4 wire system. Accuracy to IEC 751 class A, B or better. Single or duplex. Can be delivered with head mounted intrinsically safe transmitter. Insertion length as required. Ordering code Type LEX25A

LEX25B Explosion Proof Resistance Thermometer Eexi for zone 0,1 and 2
II 1 G EEx ia IIC T4..T6 certified. According EN50014, EN50020 and EN50284 Designed to measure temperatures in industrial explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Thermowell connection by a 1/2"NPT nipple union nipple. Aluminium connection head model CE with threaded cover. Stainless steel connection head optional. Cable entry M20x1.5mm. Replaceable springloaded 6mm measuring insert. Sensor Pt100 2, 3 or 4 wire system. Accuracy to IEC 751 class A, B or better. Single or duplex. Can be delivered with head mounted intrinsically safe transmitter. Insertion length as required Ordering code Type LEX25B

LEX25C Explosion Proof Resistance Thermometer EExi for zone 0,1 and 2
II 1 G EEx ia IIC T4..T6 certified. According EN50014, EN50020 and EN50284 Designed to measure temperatures in industrial explosive environments with gaseous or liquid. Temperature sensor range: -200C to 550C. Sensor Pt100 2, 3 or 4 wire system. Single or duplex. Accuracy to IEC 751 class A, B or better. Insertion length and diameter as required. Process connection by an optional compression gland or feedthrough Direct connected PVC, PE or PTFE cable with screen and drainwire. Optional: armoured cable. Epoxy filled pot seal IP65 rated. Ordering code Type LEX25C

LEX25 Pt100 Thermometer EEx i with Integrated Transmitter


According EN50014, EN50020 and EN50284 for area 0,1 & 2. Intrisically safe transmitter integrated, model and range to be specified. Designed to measure temperatures in explosive gaseous or liquid environments. Sensor Pt100 2, 3 or 4 wire system. Single or duplex. Accuracy to IEC 751 class A, B or better. Temperature range: -200C to 550C. Thermowell connection by a 1/2"NPT nipple union nipple. Aluminium connection head DAN-AK with swing cover. Stainless steel connection head optional. Cable entry M20x1.5mm. Insertion length as required. Ordering code Type LEX25

Weteringweg 10 2641 KM Pijnacker The Netherlands

Phone +31 (0)15 - 3621200 Fax +31 (0)15 - 3694082 Email sales@thermo.nl Internet http://www.thermo-electra.com

ATEX Certified Pt100 sensors

LEX30 Explosion Proof Resistance Thermometer EEx d for zone 1 and 2


II 2 G EEx d IIC T6 certified. According EN50014 and EN50018 Designed to measure temperatures in industrial explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Sensor Pt100 2, 3 or 4 wire system. Accuracy to IEC 751 class A, B or better. Single or duplex. Thermowell connection by a 1/2"NPT Fire Lock nipple union nipple. Aluminium connection head model XD-AD or Stainless Steel EExd connection head with threaded cover. Cable entry M20x1.5mm or 1/2"NPT. Replaceable springloaded 6mm measuring insert. Can be delivered with integral head mounted transmitter. Insertion length as required. Ordering code Type LEX30

LEX30 Pt100 Thermometer EEx d with Integrated 2-Wire Transmitter


II 2 G EEx d IIC T6 certified. According EN50014 and EN50018 Transmitter integrated, model and range to be specified. Designed to measure temperatures in industrial explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Sensor Pt100 2, 3 or 4 wire system. Accuracy to IEC 751 class A, B or better. Single or duplex. Thermowell connection by a 1/2"NPT Fire Lock nipple union nipple. Aluminium connection head model XD-AD or Stainless Steel EExd connection head with threaded cover. Cable entry M20x1.5mm or 1/2"NPT. Replaceable 6mm insert with 10mm spring action. Insertion length as required. Ordering code Type LEX30

LEX35A Explosion Proof Resistance Thermometer EEx d for zone 1 and 2


II 2 G EEx d IIC T6 certified. According EN50014 and EN50018 Designed to measure temperatures in industrial explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Sensor Pt100 2, 3 or 4 wire system. Single or duplex. Accuracy to IEC 751 class A, B or better. Insertion length as required. Process connection by an optional compression gland or feedthrough Direct connected PVC/PE cable with screen and drainwire. Sensor diameter to be specified. Direct connected PVC/PE cable with screen and drainwire. Screen electrical isolated from the metal sensor sheath. Ordering code Type LEX35A

LEX35B Explosion Proof Resistance Thermometer EEx d for zone 1 and 2


II 2 G EEx d IIC T6 certified. According EN50014 and EN50018 Designed to measure temperatures in industrial explosive gaseous or liquid environments. Temperature sensor range: -200C to 550C. Sensor Pt100 2, 3 or 4 wire system. Single or duplex. Accuracy to IEC 751 class A, B or better. Insertion length as required. Process connection by an optional compression gland or feedthrough Direct connected PVC/PE cable with screen and drainwire. Sensor diameter to be specified. Direct connected PVC/PE cable with screen and drainwire. Screen electrical connected to the metal sensor sheath Ordering code Type LEX35B