Sie sind auf Seite 1von 9

Septic Tank & Sock Pit

SRCETC/TBM

Design a Septic tank for a colony with

100Quarters. Assume all other data required.

1. 2. 3. 4. 5. 6. 7. 8.

Given:- No Of Qrs = 100Nos Assumed:Water supply=200lit/per/day No of persons per Qrs = 5Nos Sewage generation = 80% of water supply Detention period = 18hours Cleaning period = once in a year L:B = 4:1 & Depth of Storage of water = 1.8m Sludge deposit = 30lit/person/year Min Free Board required = 30cm (Rec= 50cm) SRCETC/TBM

Septic Tank Calculation

Total Waste water coming to septic tank = 100*5*200*80/100=80000 lit/day Detention period = 18hours capacity of tank required =80000/24*18=60000lit Capacity req for sludge accumulation = 30*5*100 = 15000lit / year Total capacity req = 60000 + 15000= 75000lit Plan area of the Septic tank = 75/1.8=41.67m2 L:B taken as 4:1, 4B*B= 41.67,B = ( 41.67/4) B = 3.25m. L = 3.25* 4 = 13m. SRCETC/TBM Total depth of Septic tank = 1.8+0.5= 2.30m

Septic Tank

SRCETC/TBM

Soak Pit Design Calculation


Waste water coming out from septic tank= 80000lit / day Percolation rate = 1500 lit / m3 / day Volume of filter media = 80000 / 1500 = 53m3 Depth taken = 2.5m Area of soak pit = 53/2.5 = 21.2 sqm Dia of Soak well req= 21.2*4 / = 5.2m

SRCETC/TBM

Unlined Sock Pit

SRCETC/TBM

Lined Sock Pit

SRCETC/TBM

Dispersion Trench

SRCETC/TBM