Beruflich Dokumente
Kultur Dokumente
Catalogue January
06
Contents
Selection guide
Application
Miniature relays
Number and type of contacts / conventional thermal current (Ith on N/O contact)
2 C/O / 12 A 3 C/O / 10 A 4 C/O / 6 A 4 C/O / 3 A (low level) 24240 V 12220 V Flat (Faston type) Up to 250 V 100 000 10 000 000 Yes (depending on version) Yes Yes
a c
Type of pins Operational voltage Durability (operating cycles) Functions Electrical, resistive load Mechanical, no-load LED Test button and mechanical indicator Low level contacts
Type reference
RSB
RXM
Page
11 and 12
Accessories Protection modules Timer module Maintaining clamps Socket identification legend Mounting adapters for 5 rail Mounting adapters with fixing lugs Bus jumper, 2-pole (Ith = 5 A) Associated socket types
RSZ E1SppM
RXZ E2Mppp
RXZ E2Sppp
Pages
6 12 12 (1) When using relay RSB 1A160pp with socket RSZ E1S48M, terminals must be linked. (2) Except for sockets RXZ E2S11pM: 10 A.
2 C/O / 10 A 3 C/O / 10 A
A A A A
24230 V 12220 V Cylindrical Up to 250 V 100 000 5 000 000 Yes (depending on version) Yes Yes
Flat (Faston type) Up to 250 V 100 000 10 000 000 Yes (depending on version) Yes
RUM
RPM
RPF
19
27
34
16 A Mixed Connector
Yes
Yes Yes (for 3 and 4-pole) Yes (on socket RPZ F1) Yes Yes Yes
RUZ CpM
RUZ SCpM
RUZ SF3M
RPZ Fp
20 20 28 (3) 30 A when mounted with 13 mm gap between two relays and 25 A when mounted side by side without a gap.
Presentation, characteristics
523139
5 2
3
535188
Socket description
Sockets with separate contact terminals (1) 1 Connection by connector. 2 Five or eight female contacts for the relay pins. 3 A fixing hole for panel mounting. 4 Location for protection modules. 5 Locking components for plastic maintaining clamp. 6 Locating slot for mounting on 5 rail.
(1) The inputs and outputs are separate from the relay supply.
1
Inputs
Outputs
2 5 3 4
Relay supply
General characteristics
Conforming to standards Product certifications Ambient air temperature around the device C Storage C Operation Vibration resistance Conforming to IEC/EN 60068-2-6 Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position IEC/EN 61810-1, UL 508, CSA C22-2 n 14 UL, CSA - 40+ 85 c - 40+ 85, a - 40...+ 70 > 10 gn (10150 Hz) IP 40 5 gn 10 gn RT I Any
Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV a V a V a V 400 3.6 (1.2/50 s) 5000 2500 1000
Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal current (Ith) Rated operational current in utilisation categories AC-1 and DC-1 Maximum operating rate In operating cycles/hour Switching voltage Switching capacity RSB 1A120pp 1 C/O AgNi 12 12 6 72 000 600 a 400, c 300 5 3000 RSB 1A160pp 1 C/O 16 16 8 RSB 2A080pp 2 C/O 8 8 4
A N/O N/C A A
V mA VA
4000
2000
References: page 6
Characteristics
50 16 12 8 5 2 1 0,5
A
106
B C A
C
105
0,4
A RSB 2A080pp
B RSB 1A160pp
C RSB 1A120pp
Coil characteristics
Average consumption Drop-out voltage threshold Operating time Between coil energisation (response time) and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact a c a c ms ms ms ms V V V c 0.45 W, a 0.75 VA c 0.1 Uc, a 0.15 Uc About 12 About 9 About 10 About 4 6 RD 90 4.8 6.6 12 JD 360 9.6 13.2 24 BD 1440 19.2 26.4 B7 400 19.2 20.4 26.4 48 ED 5700 38.4 52.8 E7 1550 38.4 40.8 57.6 60 ND 7500 48 66 110 FD 25 200 88 121 120 F7 10 200 96 102 144 220 M7 35 500 176 187 264 230 P7 38 500 184 195.5 276 240 U7 42 500 192 204 288
Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating Min. voltage limits Max. Relay control voltage codes AC Average resistance at 20 C 15% 50/60 Hz Operating Min. 50 Hz voltage limits 60 Hz Max. 50/60 Hz
V V
Socket characteristics
Socket type Relay types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement RSZ E1S35M RSB 1A120pp RSZ E1S48M RSB 2A080 pp RSB 1A160 pp (1)
A mm2 mm2 Nm
UL, CSA 12 IP 20 1 conductor: 0.52.5 mm 2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm 2 (AWG 20AWG 14) 1 conductor: 0.22.5 mm 2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm 2 (AWG 24AWG 16) 0.6 (M3 screw) Separate
(1) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 7.
Presentation: page 4
References: page 6
References
560583
10 10 10 10 10 10
560584
10 10 10 10 10 10
RSB 1A120B7 RSB 1A120E7 RSB 1A120F7 RSB 1A120M7 RSB 1A120P7 RSB 1A120U7
RSB 1A160B7 RSB 1A160E7 RSB 1A160F7 RSB 1A160M7 RSB 1A160P7 RSB 1A160U7
RSB 2A080B7 RSB 2A080E7 RSB 2A080F7 RSB 2A080M7 RSB 2A080P7 RSB 2A080U7
Sockets - 12 A, a 300 V
Contact terminal arrangement RSB 1A160BD + RSZ E1S48M Separate Connection Connector Relay type RSB 1A120pp RSB 1A160pp(2) RSB 2A080pp Voltage V c 6230 a 2460 a 110240 c 624 c 2460 c 110230 c or a 624 c or a 2460 c or a 110230 Sold in lots of 10 10 Unit reference RSZ E1S35M RSZ E1S48M Weight kg 0.060 0.050
560582
Protection modules
Description For use with All sockets All sockets Sold in lots of 20 10 10 10 10 10 10 10 10 Unit reference RZM 040W RZM 041BN7 RZM 041FU7 RZM 031RB RZM 031BN RZM 031FPD RZM 021RB RZM 021BN RZM 021FP Weight kg 0.003 0.010 0.010 0.004 0.004 0.004 0.005 0.005 0.005
Diode RC circuit
All sockets
All sockets
Accessories
560585
Sold in lots of 10 10
(1) To order a relay complete with socket (sold in lots of 20): add suffix S to the references selected above. Example: RSB 2A080RD + RSZ E1S48M becomes RSB 2A080RDS. (2) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 7. RSZ R215
Presentation: page 4
Dimensions, schemes
Dimensions
Interface relays
RSB 1A120pp RSB 2A080pp, RSB 1A160pp
3,5
15,7 3,9
12,5 7,5
15,7 3,9 5 29
12,5 7,5
3,5
16,5
2,5
Sockets
RSZ E1S35M RSZ E1S48M
67 61
(4)
67 61
2,5
15
29
(4)
11
14
21
11
24
14
12
22
12
(1)
78,5
(1)
78,5
29,4
(2)
A2 A1
(2)
A2 A1
27,5 34,5 50
(1) Relays (2) Add-on protection module (3) Maintaining clamp (4) Legend
15,5 50
27,5 34,5
15,5
Schemes
Interface relays
RSB 1A120pp RSB 1A160 pp
12/22 14/24
RSB 2A080pp
A2
A2
22
12
12
14
11/21
A1
14
24
A1
11
11
14 11 12
24 21 22
14 11 12
24 21 22
21
A1
A2
When using relay RSB 1A160 pp with socket RSZ E1S48M: terminals 11 and 21, 14 and 24, 12 and 22 must be linked
Presentation: page 4
A1
References: page 6
A2
A1
A2
A1
A2
14 11 12
29,4
(3)
(3)
Presentation
535234
7 2
4 or 5 6 3
Relay description
8 1 2 3 4 7 6 9 5 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical relay status indicator. 3 Removable lock-down door enabling forced maintaining of the contacts for test or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs. 7 Eight, eleven or fourteen Faston type pins. 8 Area by which the product can be easily gripped. 9 Mounting adapter enabling direct mounting of the relay on a panel. 10 Mounting adapter enabling direct mounting of the relay on a 5 rail.
535189
535192
523151
523152
10
6
535190
Socket description
1 Sockets with mixed contact terminals (1) 1 Connection by screw clamp terminals or connector. 2 Fourteen female contacts for the relay pins. 3 Location for protection modules. 4 Locking components for plastic and metal maintaining clamps. 5 Locating slot for mounting on 5 rail with fixing clip. 6 Two or four fixing holes for panel mounting.
Outputs
2 4 3
Inputs
5 6
535191
Relay supply
1
Inputs
Outputs
2 4 3
Sockets with separate contact terminals (2) 1 Connection by connector. 2 Eight, eleven or fourteen female contacts for the relay pins. 3 Location for protection modules. 4 Locking components for plastic and metal maintaining clamps. 5 Locating slot for mounting on 5 rail with fixing clip. 6 Two fixing holes for panel mounting. 7 Location for bus jumpers (see mounting on sockets on page 14).
(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the opposite side of the socket. (2) The inputs and outputs are separated from the relay supply terminals.
5 7
Relay supply
Schemes: page 15
Characteristics
General characteristics
Conforming to standards Product certifications C Ambient air temperature around Storage the device Operation C Vibration resistance Conforming to IEC/EN 60068-2-6 Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14 UL, CSA pending - 40 + 85 - 40 + 55 > 6 gn (10...50 Hz) IP 40 10 gn 5 gn RT I Any
Insulation characteristics
Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV a V a V a V 250 (IEC), 300 (UL, CSA) 3.6 (1.2/50 s) 2500 2500 1500
Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal For ambient current (Ith) temperature y 55 C Rated operational current Conforming to IEC N/O in utilisation categories N/C AC-1 and DC-1 Conforming to UL Maximum operating rate No-load In operating cycles/hour Under load Switching voltage Maximum Switching capacity Minimum Maximum Utilisation coefficient Mechanical durability In millions of operating cycles Electrical durability Resistive load In millions of operating Inductive load cycles/hour Electrical durability of contacts Resistive load a RXM 2ABppp 2 C/O AgNi 12 12 6 12 18 000 1200 a/c 250 10 mA on 17 V 3000 20 % 10 0.1 See curves below RXM 3ABppp 3 C/O 10 10 5 10 RXM 4ABppp 4 C/O 6 6 3 6 RXM 4GBppp 4 C/O AgAu 3 2 1 3
V mA VA
2500
1500
2 mA on 5 V 1500
107
10 6 3
106
0,4
A D C
50 100 150
105 0
D C
B
3 0,3 10,8 0,6 0,4 0,2 cos 0,1 0
A RXM 2ABppp
B RXM 3ABppp
C RXM 4ABppp
D RXM 4GBppp
Schemes: page 15
Characteristics substitution
(continued),
1
Coil characteristics
Average consumption Drop-out voltage threshold Operating time (response time) Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating voltage limits a c a c a c a c VA W 1.2 0.9 u 0.15 Uc u 0.1 Uc 20 20 20 20 12 JD 160 9.6 13.2 24 BD 650 19.2 26.4 B7 180 19.2 26.4 48 ED 2600 38.4 52.8 E7 770 38.4 52.8 110 FD 11 000 88 121 120 F7 4430 96 132 125 GD 11 000 100 138 220 MD 14 000 176 242 M7 15 000 176 242 230 P7 15 000 184 253 240 U7 15 500 192 264
ms ms ms ms V
Min. Max.
V V
Relay control voltage codes AC Average resistance at 20 C 15% Operating voltage limits
Min. Max. V V
Socket characteristics
Socket type Relay types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement Bus jumper Ith: 5 A RXZ E2S108M RXZ E2S111M RXM 2ppppp RXM 3ppppp RXZ E2S114M RXZ E2M114 RXZ E2M114M RXM 4ppppp RXM 2ppppp(1) RXM 2ppppp(1) RXM 4ppppp RXM 4ppppp
UL, CSA (pending) 12 10 IP 20 mm2 1 conductor: 0.52.5 mm2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm2 (AWG 20AWG 14) mm2 1 conductor: 0.22.5 mm2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm2 (AWG 24AWG 16) Nm 0.6 (M3 screw) Separate Mixed Yes No (1) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A. A Old ranges New range
Substitution table
RXN Miniature relays
RXN 21E1ppp RXN 41G1ppp RXN 41G1pppTQ RXN 21E1pppTQ
RXL
RXL 2A12Bppp RXL 3A10Bppp RXL 4A06Bppp RXL 4G06B ppp RXL 2A12Bppp TQ RXL 4A06Bppp TQ
RXM
RXM 2ABppp RXM 3ABppp RXM 4ABppp RXM 4GBppp RXM 2ABpppTQ RXM 4ABpppTQ
Sockets
RXZ E1M114 RXZ 7G RXZ E1M114M RXZ E1p1ppM RXZ E1M114 RXZ 7G RXZ E1M114M RXZ E1p1ppM RXZ E2M114 RXZ E2M114M RXZ E2M114M RXZ E2p1ppM
Protection modules
RXM 040MD RZM 040W RZM 031pp RZM 041pp7 RZM 021pp RXM 040MD RZM 040W RZM 031 pp RZM 041 pp7 RZM 021 pp RXM 040W RXM 040W RXM 040W (2) RXM 041pp 7 RXM 021pp (2)
Accessories
RXZ 200 RXZ 200 RXZ R235 RXZ R235 RXZ L320 RXZ L320 (2) d Protection module without LED. Dimensions: Schemes: pages 13 and 14 page 15 RXZ 400 RXZ R335 RXZ L420
Presentation: page 8
10
References
535189
Weight kg 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036
RXM pAB2F7
RXM 2AB2JD RXM 2AB2BD RXM 2AB2ED RXM 2AB2FD RXM 2AB2B7 RXM 2AB2E7 RXM 2AB2F7 RXM 2AB2P7
RXM 4AB2JD RXM 4AB2BD RXM 4AB2ED RXM 4AB2FD RXM 4AB2GD RXM 4AB2B7 RXM 4AB2E7 RXM 4AB2F7 RXM 4AB2P7
24 48 120 230
Miniature relays with low level contacts, without LED (sold in lots of 10)
Control circuit voltage Number and type of contacts Thermal current (Ith) 4 C/O - 3 A Unit Weight reference kg RXM 4GB1JD 0.036 RXM 4GB1BD 0.036 RXM 4GB1ED 0.036 RXM 4GB1FD 0.036 RXM 4GB1B7 RXM 4GB1E7 RXM 4GB1F7 RXM 4GB1P7 0.036 0.036 0.036 0.036
RXM 4GB2F7
Miniature relays with low level contacts, with LED (sold in lots of 10)
c 12 c 24 c 48 c 110 a a a a a 24 48 120 230 240 RXM 4GB2JD RXM 4GB2BD RXM 4GB2ED RXM 4GB2FD RXM 4GB2B7 RXM 4GB2E7 RXM 4GB2F7 RXM 4GB2P7 RXM 4GB2U7 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036
Presentation: page 8
Schemes: page 15
11
References
(continued)
535235
Weight kg 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036 0.036
535211
Sockets
Contact terminal arrangement Mixed Connection Screw clamp terminals Connector Separate Connector Relay type RXM 2pppp(3) RXM 4pppp RXM 2pppp(3) RXM 4pppp RXM 2pppp RXM 3pppp RXM 4pppp Sold in lots of 10 10 10 10 10 Unit reference RXZ E2M114 (1) RXZ E2M114M (1) RXZ E2S108M (2) RXZ E2S111M (1) RXZ E2S114M (1) Weight kg 0.048 0.056 0.058 0.066 0.070
Protection modules
RXZ E2S114M + Relay RXM 4AB2F7 Description Voltage V c 6...250 a 24...60 a 110...240 a/c 6...24 a/c 24...60 a/c 110...240 For use with All sockets All sockets All sockets All sockets All sockets All sockets Sold in lots of 20 20 20 20 20 20 Unit reference RXM 040W RXM 041BN7 RXM 041FU7 RXM 021RB RXM 021BN RXM 021FP Weight kg 0.003 0.010 0.010 0.030 0.030 0.030
Diode RC circuit
535212
Varistor
Timing relays
Description
535195
Weight kg
Accessories
Description RE XL4 pp Metal maintaining clamp Plastic maintaining clamp Bus jumper, 2-pole (Ith: 5 A) Mounting adapter for 5 rails (5) Mounting adapter with fixing lugs for panel Clip-in legends For use with All sockets All sockets All sockets with separate contacts All relays All relays All relays (sheet of 108 legends) All sockets except RXZ E2M114 Sold in lots of 10 10 10 10 10 10 10 Unit reference RXZ 400 RXZ R335 RXZ S2 RXZ E2DA RXZ E2FA RXZ L520 RXZ L420 Weight kg 0.001 0.005 0.005 0.004 0.002 0.080 0.001
535215
RXZ 400
(1) Thermal current Ith: 10 A (2) Thermal current Ith: 12 A (3) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A. (4) Please consult the "Zelio Time timing relays" catalogue. (5) Test button becomes inaccessible.
Presentation: page 8
Schemes: page 15
12
Dimensions
Dimensions
Miniature relays
RXM pppppp Common view RXM 2 Pin side view RXM 3 RXM 4
= 6,5 6 4 4
= = =
27
Sockets
RXZ E2M114 RXZ E2M114M
40 19 25,5
43 17
24 6 14 5 22 2 12 1 44 8 42 4 34 7 32 3 24 14 6 5
(4)
34 7 44 8 42 4 32 3
22 12 2 1
79
61
39,5
80
(1)
(1)
(2) (3)
11 A2 14 41 12 31 11 A1 13 21 10 9
(2) (3)
A2 14 41 12 31 11 21 10
A1 13 11 9
50 3,5 9 23 7 69
RXZ E2S108M RXZ E2S111M RXZ E2S114M
23,5 27
21 30
67
30
61 19
41 12 44 8 42 4 11 9 14 5 12 1 31 9 34 6 32 3 22 2 24 5 12 1 21 8 14 4 11 7 41 12 44 8 42 4 31 11 34 7 32 3 21 11 10 9 24 14 6 5 22 12 2 1
(1)
79
38
38
A2 14 13
A1
A2 14 13
A1
3,5
23 7
23,5 27
23,5 27
23,5 27
(1) Relays (2) Add-on protection module (3) Maintaining clamp (4) 2 elongated holes 3.5 x 6.5 (5) 2 bus jumpers
Presentation: page 8
Schemes: page 15
38
40
13
Dimensions (continued)
Dimensions (continued)
Plastic clamp and clip-in legends
RXZ R335 RXZ L420 Mounting on all sockets (1)
57 12
26,5 14,2
(1)
27
81
Bus jumper
RXZ S2 Mounting on sockets with separate contacts (view from below) Example of bus jumper mounting on sockets
Metal clamp
RXZ 400
25 7,3 26
2,2
22 2,3
(1)
(1) 37
(2)
(2)
1,2
(1) 2 bus jumpers (polarity A2) (2) 2 bus jumpers (polarity A1)
38
43
48
3,5 6 23 51 4 24 48 49 3
3,5
4 24
Presentation: page 8
14
38
94,5
Schemes
Schemes
Miniature relays
RXM 2ppppp
A2 12 14 44 42
RXM 3ppppp
A2 12 14 22 24 34 32
RXM 4ppppp
12 14 22 24 32 34 42 44 A2 4 42 8 44 12 41 14 A2 A1
A1
11
11
21
A1
11
21
41
31
31
1 12 5 14 9 11 13 A1
4 42 8 44 12 41 14 A2
1 12 4 14 7 11 13 A1
2 22 5 24 8 21
3 32 6 34 9 31 14 A2
1 12 5 14 9 11 13 A1
2 22 6 24 10 21
3 32 7 34 11 31
Presentation: page 8
41
15
Presentation
535216
4 5 3
7
535196
Relay description
1 2 3 4 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical relay status indicator. 3 Removable lock-down door enabling forced maintaining of the contacts for test or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Eight or eleven cylindrical or flat (Faston type) pins. 7 Area by which the product can be easily gripped.
535218
1
Outputs
Socket description
Sockets with mixed contact terminals (1) 1 Connection by connector. 2 Eight or eleven female contacts for the relay cylindrical pins. 3 Location for protection modules or the timer module. 4 Locking component for metal maintaining clamp. 5 Locating slot for 5 rail mounting. 6 Two fixing holes for panel mounting.
2 6 4 3
Relay supply
6
535197
Inputs
Outputs
4 2a 3
535198
Sockets with separate contact terminals (2) 1 Connection by connector. Inputs 2 a Eight or eleven female contacts for the relay cylindrical pins. b Eleven female contacts for the relay flat pins. 3 Location for protection modules or the timer module. Outputs 4 Locking component for metal maintaining clamp. 5 Locating slot for mounting on 5 rail with fixing clip. 2b 6 Two fixing holes for panel mounting. 7 Location for bus jumpers (see mounting on sockets on page 22). 4 1 3
(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the opposite side of the socket. (2) The inputs and outputs are separated from the relay supply terminals.
57
Relay supply
57
5 Relay supply
Schemes: page 22
16
Characteristics
General characteristics
Conforming to standards Product certifications Ambient air temperature around the device C Storage Operation C Vibration resistance Conforming to IEC/EN 60068-2-6 Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14 UL, CSA (pending) - 40 + 85 - 40 + 55 4 gn (10...50 Hz) IP 40 10 gn 5 gn RT I Any
Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Ump) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV a V a V a V 250 (IEC), 300 (UL, CSA) 3.6 (1.2/50 s) 2500 2500 1500
Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal For ambient current (Ith) temperature y 55C Rated operational current Conforming to IEC N/O in utilisation categories N/C AC-1 and DC-1 Conforming to UL Maximum operating rate No-load In operating cycles/hour Under load Switching voltage Maximum Switching capacity Minimum Maximum Utilisation coefficient Mechanical durability In millions of operating cycles Electrical durability In millions of operating cycles/hour Resistive load Inductive load . A A A A RUM F2ppp 2 C/O AgNi 10 10 5 10 36 000 3600 a/c 250 10 mA on 17 V 2500 20 % 5 0.1 See curves below Reduction coefficient for inductive load a (depending on power factor cos )
Reduction coefficient (A)
V mA VA
3 mA on 5 V 750
107
10 3
106
0,4
A B
105 0 1 2 Switching capacity (kVA) 3
B RUM C3Gppp
Schemes: page 22
17
Characteristics
(continued)
Coil characteristics
Average consumption Drop-out voltage threshold Operating time (response time) Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact a c a c a c a c VA W 2...3 1.4 u 0.15 Uc u 0.1 Uc 20 20
ms ms
ms ms
20 20
Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating voltage limits Relay control voltage codes AC Average resistance at 20 C 15% Operating voltage limits
V Min. Max. V V
60 ND 2790 48 66
Min. Max. V V
Socket characteristics
Socket type Relay types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement Bus jumper Ith: 5 A RUZ C2M RUZ C3M RUZ SC2M RUM C2ppppp RUM C3 ppppp RUM C2ppppp UL, CSA (pending) 12 IP 20 1 conductor: 0.52.5 mm2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm2 (AWG 20AWG 14) 1 conductor: 0.22.5 mm2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm2 (AWG 24AWG 16) 0.6 (M3 screw) Mixed Separate No Yes RUZ SC3M RUZ SF3M RUM C3 ppppp RUM F ppppp
A mm2 mm2 Nm
Presentation: page 16
Schemes: page 22
18
References
References
Relays for standard applications, without LED (sold in lots of 10)
Pins Control circuit voltage Number and type of contacts - Thermal current (Ith) 2 C/O -10 A 3 C/O -10 A Unit Weight Unit reference reference kg RUM C2AB1JD 0.084 RUM C3AB1JD RUM C2AB1BD 0.084 RUM C3AB1BD RUM C2AB1ED 0.084 RUM C3AB1ED RUM C3AB1ND RUM C2AB1FD 0.084 RUM C3AB1FD RUM C3AB1GD RUM C3AB1MD RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM RUM C2AB1B7 C2AB1E7 C2AB1F7 C2AB1P7 F2AB1JD F2AB1BD F2AB1ED F2AB1FD F2AB1B7 F2AB1E7 F2AB1F7 F2AB1P7 C2AB2JD C2AB2BD C2AB2ED C2AB2FD 0.084 0.084 0.084 0.084 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 RUM C3AB1B7 RUM C3AB1E7 RUM C3AB1F7 RUM C3AB1P7 RUM F3AB1JD RUM F3AB1BD RUM F3AB1ED RUM F3AB1FD RUM F3AB1B7 RUM F3AB1E7 RUM F3AB1F7 RUM F3AB1P7 RUM C3AB2JD RUM C3AB2BD RUM C3AB2ED RUM C3AB2ND RUM C3AB2FD RUM C3AB2GD RUM C3AB2B7 RUM C3AB2E7 RUM C3AB2F7 RUM C3AB2P7 RUM F3AB2JD RUM F3AB2BD RUM F3AB2ED RUM F3AB2FD RUM F3AB2B7 RUM F3AB2E7 RUM F3AB2F7 RUM F3AB2P7
Weight kg 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.084 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.088 0.086 0.086 0.086 0.086 0.086 0.086 0.086 0.086
Cylindrical
c c c c a a a a
535199
RUM ppAB2B7
C2AB2B7 C2AB2E7 C2AB2F7 C2AB2P7 F2AB2JD F2AB2BD F2AB2ED F2AB2FD F2AB2B7 F2AB2E7 F2AB2F7 F2AB2P7
535200
RUM ppAB2F7
Relays with low level contacts, with LED (sold in lots of 10)
Pins Control circuit voltage Number and type of contacts Thermal current (Ith) 3 C/O - 3 A Unit Weight reference kg RUM C3GB2BD 0.086 RUM C3GB2ED 0.086 RUM C3GB2B7 RUM C3GB2E7 RUM C3GB2F7 RUM C3GB2P7 0.086 0.086 0.086 0.086
Cylindrical
V c 24 c 48 a a a a 24 48 120 230
Presentation: page 16
Schemes: page 22
19
535199
References (continued)
Sockets
Contact terminal arrangement Mixed Connection Connector Relay type RUM C2ppppp RUM C3 ppppp Separate Connector RUM C2 ppppp RUM C3 ppppp RUM F2 pppp RUM F3 pppp Sold in lots of 10 10 10 10 10 Unit reference RUZ C2M RUZ C3M RUZ SC2M RUZ SC3M RUZ SF3M Weight kg 0.054 0.054 0.095 0.100 0.095
Protection modules
Description For use with All sockets All sockets All sockets Voltage V c 6250 a 110240 a/c 24 a/c 240 Sold in lots of 10 10 10 10 Unit reference RUW 240BD RUW 241P7 RUW 242B7 RUW 242P7 Weight kg 0.004 0.004 0.004 0.004
Diode
535202
Timer module
Description
535219
Sold in lots of 10
Weight kg 0.020
Timing relays
Description 2 timed C/O contacts (single-function or multifunction) For use with On sockets RUZ CpM Reference RE 48A pp (1) Weight kg
Accessories
Description
535217
Metal maintaining clamp RUZ C200 Bus jumper, 2-pole (Ith : 5 A) Clip-in legends
For use with All sockets All sockets with separate contacts All relays (sheet of 108 legends) All sockets with separate contacts
Sold in lots of 10 10 10 10
535203
RUZ S2
Substitution table
Old range New range
RUM
RUM RUM RUM RUM RUM F2ABppp F3ABppp C2ABppp C3ABppp C3GB2pp
Sockets
RUZ pA RUZ pD RUZ 1C RUZ C3M RUZ C2M RUZ SF3M RUW 240BD (2) RUW 24ppp (2) RUZ C200
Protection modules
RUW 030BD RUW 04ppp
Accessories
RUZ 2p0 (2) d Protection module without DEL. Presentation: page 16 Characteristics: pages 17 and 18 Dimensions: pages 21 and 22 Schemes: page 22
20
Dimensions
Dimensions
Universal relays
RUM Cpp RUM Fpp
34
55
34
53
34
Sockets
Common side view RUZ C2M RUZ C3M
22
24 6 5 22 4 12 14 3 34 9 32 8 24 7 22 5 14 3 12 4
4 3
2x3,1
8 9
6 7 5 4 3 10 11 1 INPUT A1 2 2
2x3,1
(1) (3)
75
7 8 1
(2)
INPUT A2 7 A2 7 A2 7 21
INPUT A1 2
37
37
INPUT A2 10 A2 A2 31 10 21 11 6
11 8
A1 1 2
11 A1 1 2
10
27 63 89 93
RUZ SC2M
30 38
30 38
RUZ SC3M
45 19
22 5 24 6 11 1 21 8 12 4 14 3
63 19
31 11 34 9 32 8 21 6 24 7 22 5 11 1 14 3 12 4
(1)
92
4
6 7
4 3
(1) (3)
2
4
7 6 5 8 4 3 9 10 2 11 1
(3)
40
92
(2) (4)
29 75 102 105 4
(2)
A2 7 A1 2
40
A2 10
34
(4)
29 75 102 105 4
A1 2
30 36
32 36
(1) Relay (2) Protection module (3) Maintaining clamp (4) 2 bus jumpers
Presentation: page 16
Schemes: page 22
21
Dimensions (continued)
Sockets (continued)
RUZ SF3M
63
21 9 24 6 22 3 31 8 34 5 32 2 11 7 14 4 12 1
(1) (3)
92
(2) (4)
27 46 104 29 4
A2 B A1 A
36
(1) Relay (2) Protection module (3) Maintaining clamp (4) 2 bus jumpers
Bus jumper
RUZ S2
32 1,2 54 2,3
Mounting on sockets with separate contacts (view from below) Example of bus jumper mounting on sockets (1) (1)
RUZ L420
32 14,2 12
108
(2)
(2)
(1) 2 bus jumpers (polarity A2) (2) 2 bus jumpers (polarity A1)
Schemes
Universal relays
RUM p2ABppp
14 12 22 24 A2
RUM C3 ppppp
14 24 34 12 22 32 A2
RUM F3ABppp
14 34 12 32 22 24 21 2 32 5 34 8 31 A2 A1 3 22 6 24 9 21 B( ) A2
A1
11
21
11
21
31
A1
11
RUM F2ABppp
1 12 4 14 7 11 A (+) A2 A1 3 22 6 24 9 21 B( ) A2
RUM C3 ppppp
21 6 5 12 4 7 8 32
RUM F3ABppp
1 24 12 4 14 7 11 A (+) A1
12 4 14 3
22
14 3 A1 2 10 1 11 11 31
9 34 A2
A1
2 1 11 8 21
Symbols shown in blue correspond to Nema marking. Presentation: page 16 Characteristics: pages 17 and 18 References: pages 19 and 20
22
31
Setting-up
Function Timing range selection selection 0.11 s 0.110 s 0.11 min 110 min 0.11 h 110 h 0.11 day 110 days
Function selection
Selection Function On-delay timer E Control Series control Function diagram
U .1/.4 .1/.2 t
Control scheme
U
A1
Series control
U .1/.4 .1/.2 t t
Series control
U .1/.4 .1/.2 t t
Off-delay timer R
U S
U S
t
A1
.1/.4 .1/.2
A2
Series control
U .1/.4 .1/.2
U S .1/.4 .1/.2
U S .1/.4 .1/.2
On-delay timer Es
U S .1/.4 .1/.2
Presentation: page 16
A2
B1
23
Presentation
523144
8
523145
Relay description
2 3 4 1 Spring return pushbutton for testing the contacts (green: c, red: a). 2 Mechanical relay status indicator. 3 Removable lock-down door enabling forced maintaining of the contacts for test or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs. 7 Five, eight, eleven or fourteen Faston type pins. 8 Area by which the product can be easily gripped. 9 Mounting adapter enabling direct mounting of the relay on a panel. 10 Mounting adapter enabling direct mounting of the relay on a 5 rail.
7 6
523156
523157
523158
9 5
523146
10
Socket description
1
Outputs
Sockets with mixed contact terminals (1) 1 Connection by screw clamp terminals. 2 Five, eight, eleven or fourteen female contacts for the relay pins. 3 Location for protection modules or the timer module. 4 Locating slot for mounting on 5 rail with fixing clip. 5 Two or four fixing holes for panel mounting.
(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the opposite side of the socket.
Supply relay
Inputs
Schemes: page 31
24
Characteristics
General characteristics
Conforming to standards Product certifications Ambient air temperature around the device Vibration resistance Degree of protection Shock resistance conforming to IEC/EN 60068-2-27 Protection category Mounting position Storage Operation Conforming to IEC/EN 60068-2-6 Conforming to IEC/EN 60529 Opening Closing C C IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14 UL, CSA (pending) - 40 + 85 - 40 + 55 6 gn (10...50 Hz) IP 40 10 gn 10 gn RT I Any
Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and contact (rms voltage) Between poles Between contacts V kV aV aV aV 250 (IEC), 300 (UL, CSA) 3.6 (1.2/50 s) 2500 2500 1500
Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal current For ambient (Ith) temperature y 55 C Conforming to IEC N/O Rated operational current in utilisation categories N/C AC-1 and DC-1 Conforming to UL Maximum operating rate No-load In operating cycles/hour Under load Switching voltage Maximum Switching capacity Minimum Maximum Utilisation coefficient Mechanical durability In millions of operating cycles Resistive load Electrical durability In millions of operating Inductive load cycles/hour Electrical durability of contacts Resistive load a RPM 1 ppp 1 C/O AgNi 15 15 7.5 15 18 000 1200 a/c 250 100 mA on c 5 V 3750 20 % 10 0.1 See curves below Reduction coefficient for inductive load a (depending on power factor cos )
Reduction coefficient (A)
A A A A
V mA VA
0.06
107
15 10
106
0,4
Schemes: page 31
25
Characteristics
(continued)
Coil characteristics
Relay type Average consumption Drop-out voltage threshold Operating time (response time) Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact a c a c a c a c VA W RPM 1ppp 0.9 0.7 u 0.15 Uc u 0.1 Uc 20 20 20 20 12 JD 180 160 100 96 9.6 13.2 24 BD 750 650 400 388 19.2 26.4 B7 160 180 103 84.3 19.2 26.4 48 ED 2600 2600 2600 1550 38.4 52.8 E7 720 770 770 338 38.4 52.8 110 FD 13 100 11 000 8600 7340 88 121 120 F7 4430 4430 2770 2220 96 132 230 P7 15 720 15 000 12 000 9120 184 253 RPM 2ppp 1.2 0.9 RPM 3ppp 1.5 1.7 RPM 4ppp 1.5 2
ms ms ms ms V
25 25
25 25
20 20
Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10%
Operating voltage limits Relay control voltage codes AC Average resistance at 20 C 15%
V V
V V
Socket characteristics
Socket type Relay types used Protection module types used Product certifications Conventional thermal current (Ith) Degree of protection Conforming to IEC/EN 60529 Connection Solid cable without cable end Flexible cable with cable end Maximum tightening torque Contact terminal arrangement RPZ F1 RPZ F2 RPZ F3 RPM 1ppp RPM 2ppp RPM 3ppp RXM 02ppp RXM 02 ppp RUW 24ppp RXM 04ppp RXM 04 ppp UL, CSA (pending) 16 IP 20 1 conductor: 0.52.5 mm2 (AWG 20AWG 12) 2 conductors: 0.51.5 mm2 (AWG 20AWG 14) 1 conductor: 0.22.5 mm2 (AWG 24AWG 14) 2 conductors: 0.21.5 mm2 (AWG 24AWG 16) 0.8 (M3.5 screw) Mixed RPZ F4 RPM 4ppp RUW 24ppp
A mm2 mm2 Nm
Presentation: page 24
Schemes: page 31
26
References
V c 12 c 24 c 48 c 110
a 24 a 48 a 120 a 230
535205
535205
Presentation: page 24
Schemes: page 31
27
References
(continued)
535206
Sockets
Contact terminal arrangement Mixed Connection Screw clamp terminals Relay type RPM RPM RPM RPM 1ppp 2ppp 3ppp 4ppp Sold in lots of 10 10 10 10 Unit reference RPZ F1 RPZ F2 RPZ F3 RPZ F4 Weight kg 0.042 0.054 0.072 0.094
Protection modules
Description Voltage V c 6...250 Socket type RPZ F1 RPZ F2 RPZ F3 RPZ F4 RPZ F1 RPZ F2 RPZ F1 RPZ F2 RPZ F3 RPZ F4 RPZ F1 RPZ F2 RPZ F1 RPZ F2 RPZ F1 RPZ F2 RPZ F3 RPZ F4 RPZ F3 RPZ F4 Socket type RPZ F3 RPZ F4 Sold in lots of 20 20 20 20 20 20 20 20 20 20 Unit reference RXM 040W RUW 240BD RXM 041BN7 RXM 041FU7 RUW 241P7 RXM 021RB RXM 021BN RXM 021FP RUW 242B7 RUW 242P7 Weight kg 0.003 0.004 0.010 0.010 0.004 0.030 0.030 0.030 0.004 0.004
RC circuit
535207
a 24...60 a 110...240
RXM p41 ppp Varistor a/c 6..0.24 a/c 24...60 a/c 110...240 a/c 24 a/c 240
Multifunction
535208
Accessories
Description Metal maintaining clamp (for single-pole relays) Mounting adapters for 5 rail (2) For use with RPZ F1 RPM RPM RPM RPM RPM RPM RPM RPM 1ppp 2ppp 3ppp 4ppp 1ppp 2ppp 3ppp 4ppp Sold in lots of 20 20 20 20 20 20 20 20 20 10 Unit reference RPZ R235 RPZ 1DA RXZ E2DA RPZ 3DA RPZ 4DA RPZ 1FA RXZ E2FA RPZ 3FA RPZ 4FA RXZ L520 Weight kg 0.001 0.004 0.004 0.004 0.006 0.002 0.002 0.003 0.004 0.080
All relays
RPZ 3FA
(1) See timer module description (selection of functions and time delays) on page 23 (2) Test button becomes inaccessible
Presentation: page 24
Schemes: page 31
28
Dimensions
Dimensions
Power relays
RPM 1
6,5 6 5
3,5
4,5
27
2 41
Common side view
6 7
14
2,5
2,5
RPM 2
RPM 3
RPM 4
27
4,5
39
21
27
10 15
31
10
10
40
27
10
10
10
Sockets
RPZ F1 RPZ F2
19
14 5 12 1
19
4,5 x 6
44 8 14 5
40
80
68
80
40
14 11 9
13
A2 14 41 12
A1 13 11 9
31 71 80
Common side view
17 21 76
RPZ F3 RPZ F4
8 30
19 26 30
19
4,5 x 6
44 8 42 4 2 6 22 1 24 5 12 14 8
4,5 x 6
44 7 42 32 3 2 34 6 22 1 24 5 12 14
40
68
80
68
40
A2 14 41 12 10 13 21 9
A1
A2 14 13 41 12 11 31 10 21 9
A1
11
11
8 30 76
28 37 40
36 46 50
Presentation: page 24
Schemes: page 31
40
40
29
40
A2
A1
40
42 4
12 1
Dimensions (continued)
Dimensions (continued)
Mounting adapters for 5 rail
RPZ 1DA RXZ E2DA RPZ 3DA RPZ 4DA
38
49,5
48
50
23 24
2,5
23 2,5 23 24
34
43
38
43
38
43
2,5
20
50
44
3,5 16
5 16,5
43
38
3,5 19
4 24
3,5 19
4 34
16
3,5
4 44
Mounting
Mounting adapters for 5 rail (1) Mounting adapters with fixing lugs for panel
Presentation: page 24
Schemes: page 31
30
38
Schemes
Schemes
Power relays
RPM 1ppp
A2 14 12
RPM 2ppp
12 14 22 24 A2 A1
A1
11
11
1 12 5 14 9 11 13 (+) A1 14 ( ) A2
1 12 3 14 5 11 7 (+) A1
21
2 22 4 24 6 21 8 ( ) A2
RPM 3ppp
A2 12 14 42 44 22 24
RPM 4ppp
12 14 32 34 42 22 24 44 A2 4 42 8 44 12 41 14 ( ) A2 A1
11
41
A1
11
31
21
1 12 5 14 9 11 13 (+) A1
2 22 6 24 10 21
4 42 8 44 12 41 14 ( ) A2
1 12 5 14 9 11 13 (+) A1
21
2 22 6 24 10 21
3 32 7 34 11 31
Presentation: page 24
41
31
Presentation, characteristics
1 2 3 4
Four or six Faston type pins. Two relay supply pins. A locating slot for mounting on 5 rail. Two fixing holes for panel mounting.
General characteristics
Conforming to standards Product certifications Ambient air temperature around the device Vibration resistance Degree of protection Storage Operation Conforming to IEC 60068-2-6 Conforming to IEC/EN 60529 C C IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n14 UL, CSA (pending) - 40...+ 85 - 40...+ 55 >10 gn (10...55 Hz) IP 40 10 gn 10 gn RT IV Any
Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position
Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength (rms voltage) Between coil and contact Between poles Between contacts V kV aV aV aV 250 3.6 (1.2/50 s) 2500 2500 1500
References: page 34
32
Characteristics (continued)
Contact characteristics
Relay type Number and type of contacts Contact materials Conventional thermal current (Ith) Rated operational current in utilisation categories AC-1 and DC-1 Maximum operating rate In operating cycles/hour Switching voltage Switching capacity Utilisation coefficient Mechanical durability For ambient temperature y 40C Conforming to IEC Conforming to UL No-load Under load Maximum Minimum Maximum In millions of operating cycles A N/O N/C A A A RPF 2A pp 2 N/O AgSnO2 RPF 2B pp 2 C/O
V mA VA
30 (when mounted with 13 mm gap between two relays) 25 (when mounted side by side without a gap) 30 3 30 18 000 1200 a/c 250 10 mA on c 17 V 7200 10 % 5 0.05 (N/O contact only) See curves below
Resistive load Electrical durability In millions of operating Inductive load cycles/hour Electrical durability of contacts Resistive load a
107
Durability (Number of operating cycles)
A B
10
106
105
0,4
104 0 1 2 3 4 5 6 7 8
Switching capacity (kVA)
Coil characteristics
Average consumption a c a c Between coil energisation and making of the On-delay contact Between coil de-energisation and making of the Off-delay contact Control circuit voltage Uc Relay control voltage codes DC Average resistance at 20 C 10% Operating voltage limits Relay control voltage codes AC Average resistance at 20 C 15% Operating voltage limits a c a c ms ms ms ms VA W 4 1.7 u 0.15 Uc u 0.1 Uc 20 20 20 20
V Min. Max. V V
12 JD 86 9.6 13.2
Min. Max. V V
References: page 34
33
References
535210
V c 12
c 24
RPF 2ABD
RPF 2BBD
0.086
RPF 2AFD
RPF 2BFD
0.086
a 24
RPF 2AB7
RPF 2BB7
0.086
a 120
RPF 2AF7
RPF 2BF7
0.086
a 230
RPF 2AP7
RPF 2BP7
0.086
(1) 30 A when mounted with 13 mm gap between two relays and 25 A when mounted side by side without a gap.
34
Dimensions, schemes
Dimensions
Power relays
RPF 2App , RPF 2Bpp
26 16 2 x 4,5
30 4,5
42
15
60
12 = 34 = 42
Schemes
Power relays
RPF 2App
6 14 2 24
RPF 2Bpp
6 14 8 11 2 24 4 21 3 22
8 11
4 21
7 12
1 A1
0 A2
69
1 A1 0 A2
References: page 34
35
Technical appendices
Relays
Contact types
Symbol Configuration Make contact (Normally Open) EU NO USA SPST-NO DPST-NO nPST-NO (1) SPST-NC DPST-NC nPST-NC (1) SPDT DPDT nPDT (1)
NC
Changeover Contact CO
Utilisation categories
Category AC-1 Type of current a single-phase a 3-phase a 3-phase Applications Resistive or slightly inductive loads.
AC-3
Starting and braking of squirrel cage motors; reversing direction of rotation only after stopping of motor. Starting of squirrel cage motors, inching. Plugging, reversing direction of rotation. Resistive or slightly inductive loads (2). Control of electromagnetic loads (< 72 VA), auxiliary control relays, power contactors, electromagnetic solenoid valves and electromagnets. Control of electromagnetic loads (> 72 VA), auxiliary control relays, power contactors, electromagnetic solenoid valves and electromagnets. Control of electromagnetic loads, auxiliary control relays, power contactors, magnetic solenoid valves and electromagnets.
AC-4
a 3-phase
DC-1 AC-14
c a single-phase
AC-15
a single-phase
DC-13
Protection categories
Category RT 0 RT I Explanation Condition Unenclosed relay Relay not provided with a protective case. Dust protected relay Flux-proof relay Relay provided with a case which protects its mechanism from dust. Relay capable of being automatically soldered without allowing the migration of solder fluxes beyond the intended areas. Relay capable of being automatically soldered and then washed to remove flux residues without risk of ingress of flux or washing solvents. Relay provided with a case which has no venting to the outside atmosphere.
RT II
RT III
Wash-tight relay
RT IV
Sealed relay
Hermetically Sealed relay having an enhanced level of sealing. sealed relay (1) n = number of contacts. (2) The switchable voltage can be doubled, for an equal current, by connecting two contacts in series.
RT V
36
Technical appendices
(continued)
1
Protection modules
Whenever an inductive load is de-energised (coil of a relay or of a contactor), an overvoltage appears at its terminals. This voltage peak can reach several thousand volts and a frequency of several MHz. It is likely to disturb the operation of automation systems which contain electronic devices. Protection modules are used to reduce the voltage peak on de-energisation and they therefore limit the energy of interference signals to a level that will not disturb surrounding coils and electronic devices. These modules are used to avoid: v electromagnetic compatibility problems, v the deterioration of contact materials, v the destruction of insulation due to overvoltage, v the destruction of electronic components. Diode protection module (with or without LED) b Advantages v accumulation of energy allowing current flow in the same direction, v absence of any voltage peaks at the coil terminals, v low cost.
Energy released
U
Supply voltage
Break
b v v v
Disadvantages increase in relay drop-out time (3 to 4 times the usual time), no polarity protection, de-energisation of the relay.
Break
Protection module with varistor b Advantages v can be used with a and c supply, v voltage peak limited to about 2 Un, v little effect on relay drop-out time.
t
Limitation of voltage peaks
Energy released
Break
Protection module with RC circuit b Advantages v coil oscillating frequency reduced to about 150 Hz, v voltage peak limited to 3 Un, v little effect on relay drop-out time.
t U1
S2 (with RC)
S1
U2
37
A worldwide presence
Constantly available b More than 5 000 points of sale in 130 countries. b You can be sure to find the range of products that are right for you and which complies fully with the standards in the country where they are used. Technical assistance wherever you are b Our technicians are at your disposal to assist you in finding the optimum solution for your particular needs. b Schneider Electric provides you with all necessary technical assistance, throughout the world.
Due to evolution of standards and equipment, the characteristics indicated in texts and images of this document do not constitute a commitment on our part without confirmation. Design: Schneider Electric Photos: Schneider Electric Printed by:
ART. 815041
01 / 2006
DIA3ED2051206EN
Simply Smart !