EEx e, ia Junction boxes TNUP

Features
The TNUP range comprises many standard sizes of enclosures manufactured in glass bre reinforced polyester to give the best environmental protection. Product range with standard sizes. Ingress protection to meet harsh environment with IP66 as standard. Suitable for demanding environments. Temperature range (-20C to +40C). Cover screws in SS316. Many cable entry options. May be used as a connection box for intrinsically safe circuits. High operational reliability and cost efciency, reduced lifetime maintenance costs. ATEX approved.

Technor as, Dusavikv. 39, P.O. Box 658, NO-4003 Stavanger, Norway Phone: +47 51844100, Fax: +47 51844101, E-mail: mail@technor.no. www.technor.no

EEx e, ia Junction boxes


Applications
The TNUP range of boxes is suitable for demanding environment like the North Sea environment. They are ideal for Petrochemical and Marine applications and also for all kind of industry where an explosive atmosphere may be present.

General Specications
Material Glass bre reinforced polyester (GRP) IP Rating IP66 according to IEC 529 Temperature -20C +40C (T6) Approvals Standards Ex-Code DNV-2003-OSL-ATEX-0207X Cenelec EN50014, EN50019, EN50020, IEC 60529 EEx e II T6 EEx e[ia] IIC T6 EEx ia IIC T6 II 2 G Black Max. 750V PE bar and/or earth terminals Earth continuity plate/earth tag upon request Plastic or metal, quantities according to table According to table Upon request

Colour Voltage Earthing Glands Terminals Drain plug

Cover Screws SS316

Number of terminals
An ignition temperature is the temperature at which a hot surface will cause an ignition to occur in a given atmosphere. Dependent on the type of gas or dust, the maximum temperature that the surface of the terminal box can reach without a spontaneous ignition is known as the T Class. The maximum surface temperature must always be lower than the ignition temperature of the atmosphere in which the junction box is used. The terminal boxes within the TNUP range have been assigned a maximum heat dissipation relating to the ambient temperature and T Class. The TNUP range offers T6 protection: T6 = Maximum 85C (Internal wiring must have a temperature rating of at least 85C) For some applications it may be necessary to have several terminal sizes. The power heat dissipation determines the maximum number of terminals permissible for any size of terminal box, based on a 100% load. The following tables and examples demonstrate how this is solved in the same junction box. Example (TNUP 161609) Terminal/ conductor size (mm2) 1,5 2,5 4

Current (Amps) 10 16 20

Number of terminals 10 (of max 25) 6 (of max 16) 4 (of max 18) Total load

Load=100% maximum 40% 37,50% 22,22% 99,72%

EEx e, ia Junction boxes


Terminal Load Conguration
Terminal size (mm2) TNUP 121209 10 16 20 25 35 50 Current (A) 1,5 2,5 4 6 10 TNUP 161609 Terminal size (mm2) 1,5 2,5 4 6 10 16 TNUP 252512 10 16 20 25 35 50 63 80 100 125 Current (A) Terminal size (mm2) 1,5 2,5 4 6 10 16 25 35 TNUP 361609 10 16 20 25 35 50 63 80 100 125 Current (A) Terminal size (mm2) 1,5 2,5 4 6 10 16 25 35

Current (A)

16 7 14 3 8 16 3 9 12 2 6 1

10 48 16 16 32 125 20 25 35 50 63 80 7 19 36 9 20 39 6 15 38 2 12 32 4 14 6

35 12 23 90 5 13 26 6 14 28 4 11 24 1 9 19 3 10 16 4 11 13 5 11 4 Terminal size (mm2)

53 18 35 138 7 20 40 9 22 43 6 17 42 2 14 35 4 16 58 6 18 65 7 17 7 Terminal size (mm2)

TNUP 404117

1,5 2,5 4

10 16 25 35

10 37 16 12 24 96 20 5 14 28 25 7 15 30 35 4 12 29 50 1 9 24 63 3 11 40 80 4 12 19 100 10 12 125 4

TNUP 402512 10 16 20 25 35 50 63 80 100 125 Current (A)

1,5 2,5 4

10 16 25 35

38 13 25 98 5 14 28 7 16 31 4 12 30 1 9 25 3 11 41 4 22 46 5 12 4

Current (A)

Entry Table
Depth 09 Side Width 12 16 36 12 16 25 40 40 A/B M20 4 6 18 17 27 40 A/B M25 3 4 11 11 17 27 A/B M32 2 2 7 7 13 20 A/B M40 1 2 5 4 6 16

The table is guidance for the maximum quantity of glands for installation in 1 face (the Width column in the table) on TNUP junction boxes. The quantity is based upon use of Polyamide glands. Note! Recommended quantity is 2/3 of guided quantity.

Possible entry faces on TNUP.

TNUP Measurement Table - Range of stocked boxes


Type

121209 161609 252512 361609 402512 404117

Width (cm) Height (cm) Depth (cm) 123 120 91 160 160 92 255 250 120 360 160 92 400 250 120 400 405 165

Weight (kg) 1,1 1,5 2,9 2,5 4,3 6,1

GA-Dwg. TNU-35-6 TNU-36-6 TNU-37-6 TNU-39-6 TNU-49-6 TNU-40-6

The boxes are delivered with screws in lid as standard.

EEx e, ia Junction boxes


Hazardous area information & terminology
ATEX Directive
The ATEX Directive, derived from the French ATmosphres EXplosibles and formally known as 94/9/EC, contains the ESR (Essential Safety Requirements) to which electrical equipment and protective systems used within potentially explosive atmospheres must conform. The new ATEX Directive currently in place within the European Union was made mandatory on 1st July 2003. Primarily intended for manufacturers of hazardous area equipment for use in the presence of ammable gases, vapours, fumes or dusts, the new directive requires a quality management system to be implemented. Procedures for the design, manufacture and verication of products are to be approved by a notied body (i.e. DNV, NEMKO, etc.) and all equipment conforming to the new directive will feature CE and Ex Marking.

Applicable EX protection
EEx e Protection for electrical components that do not spark under normal working conditions but where measures are applied to prevent high temperatures and the occurence of arcs and sparks internally. EEx ia Protection for equipment containing intrinsically safe circuits, which are incapable of causing an explosion in the surrounding atmosphere, that is where current and voltage in normal operation would not produce enough spark energy or heat to ignite any potentially explosive gases.

Features

Zone Classication with the presence of GAS


Zone 1 (Category 2) An area in which explosive gas is likely to be present during normal operation of the plant. An area in which explosive gas is not continuously present, but may exist for a short period of time.

Zone 2 (Category 3)

Technor as, Dusavikv. 39, P.O. Box 658, NO-4003 Stavanger, Norway Phone: +47 51844100, Fax: +47 51844101, E-mail: mail@technor.no. www.technor.no

OCTOBER 2005 VERSION 1.0 ARTDIRECTOR.NO SPESIALTRYKK

Das könnte Ihnen auch gefallen