Sie sind auf Seite 1von 28

9001:2008

14001:2004
OHSAS
18001:2007

IS 7098 (Part I)

D et a il s m a ke t he D i f f e r e nc e

XLPE INSULATED
HEAVY DUTY CABLES
650/1100V.

P r o d u c t

R a n g e

L.V. PVC & XLPE POWER CABLES WITH


COPPER AND ALUMINIUM CONDUCTOR
L.V. PVC & XLPE CONTROL CABLES WITH COPPER CONDUCTOR
M.V. POWER CABLES UPTO 33 kV
EHV CABLES FROM 66kV TO 220kV
M.V. / L.V. AERIAL BUNCHED CABLES (ABC)
zero halogen cables
FIRE SURVIVAL cables (fs)
INSTRUMENTATION CABLES SCREENED / UNSCREENED
industrial braided cables
THERMO COUPLE / COMPENSATING CABLES
lead sheathed cables
rubber cables
RAILWAY SIGNALLING CABLES
TELEPHONE CABLES DRY & JELLY FILLED
BUILDING WIRES fr / frls / frzh / frlf / frfs
Single core industrial Flexibles pvc / fr / frls /
frzh / hrfr / hr / hr-frls / frlf / frfs
multi core industrial flexible cables
SUBMERSIBLE flat and round CABLES
SUBMERSIBLE Wrapped winding wires
COAXIAL CABLES
LAN CAT-5E / cat 6 CABLES
welding cables
solar AC / dc cables
steel braided cables
speciality cables suited for marine / oil & gas /
extreme fire conditions / highly corrosive
environment / traffic / aircraft / space station /
automobiles

Contents

Details make the difference

Introduction

Advantages of Polycab XLPE Cables & Selection

Comparative Current Rating and Short Circuit


Rating for XLPE Cable Vis--Vis PVC Cables

Technical Data

6-7

Tables

8-19

Rating Factors

20-22

Handling

23-24

Details make the difference

THE CO MPA NY
POLYCAB, an ISO 9001:2008, ISO
14001:2004, OHSAS 18001:2007 company
is the largest Wire & Cable manufacturer
in India with a proven track record of
over three decades. The fastest growing
company in the Indian Cable Industry
with consistent growth. Polycab group has
crossed Rs. 3600 crore turnover in the year
2010-11 and is set to achieve Rs. 4000
crore turnover in the year 201112.
From a modest beginning with Wires and
Cables, over three decades ago Polycab set
up State of Art manufacturing facilities at
Daman in 1996.The last 3 decades have
seen the core business develop along
different product lines: - Low Voltage
Cables, Medium Voltage Cables, Extra High
Voltage Cables, Fire Survival & Fire Resistant
Cables, Telecommunication Cables, Control
& Instrumentation Cables and Aerial
Bunched Cables. In the manufacture of
cables, a competitive edge lies not so
much in product innovation as in providing
consistent quality, guaranteeing reliability
and ready availability. Polycabs Daman
factory was created to address these key
market determinants. The manufacturing
set up is sourced out from the world
renowned Machinery and Technology
suppliers with constant upgradation and
expansions.

CUS TO ME R SATISFACT ION


In an ongoing process to improve Customer
Satisfaction Polycab offers a variety of
services:
Commercially competitive prices.
Reliable & consistent quality.
Reliable & just in time delivery.
Product development for a changing
market.
A targeted stocking policy.
Technical Support for Applications/
Projects

CUS TO ME R FO CUSED
POLYCAB derives its strength from its

customers. The growth of the latter is a


prerequisite to the growth of the company
and hence customers satisfaction is its
prime objective. Over the years sincere
service and dedication to its Customers
has earned the Company distinguished
Customers which includes demanding
leaders in Sectors like Utilities, Power
Generation, Transmission & Distribution,
Petroleum & Oil Refineries, Oems, EPC
contractors, Steel & Metal, Cement,
Chemical, Atomic Energy, Nuclear Power,
Consultants & Specifiers etc.
POLYCAB has highly experienced, qualified
and dedicated professionals with strong
adherence to the quality management
system. Polycab has offices all over the
country and also has a wide network of
authorized distributors and dealers to cater
to all the customer segments in India and
abroad.
POLYCAB has earned the trust and reputation
in India and abroad by winning the
customers confidence. Several thousands
kilometers of LT XLPE Cables in the voltage
range of 1.1KV have been manufactured
and are in operation in India and abroad.
Polycab LT XLPE Cables are preferred choice
in Power Plants, Distribution Systems,
Heavy Industries, Various Utilities, The
Titans of Indian Industry & Consultants /
Specifiers.

DETAILS M AK E T HE DIF FEREN C E


More than 3 decades of experience have
enabled POLYCAB to develop a specific
know how for each individual productline.
Attention to details allows the company
to apply optimum technical solutions
and material selections to each and every
different project or application.
Other available Catalogues:
Flexible Cables
LT PVC Power & Control Cables.
HT Cables upto 45KV
EHV Cables upto 132Kv
Fire Survival Cables.

Polycab Wires Pvt. Ltd. takes every precaution to ensure the information given in this publication is correct.
E & O.E. all information is subject to change without notice.

XLPE Cables
The XLPE insulated heavy duty cables were introduced worldwide in mid sixties. These
cables have overcome the limitations of PVC Insulated Cables such as thermal degradation,
poor moisture resistant and thermoplastic in nature.
The advantages of XLPE Insulated cables in comparison to PVC insulated cables are as
under:
A. Technical Advantages :

1. Higher current rating, higher Short Circuit Rating Approx 1.2 times that of PVC.

2. Thermosetting in nature.

3. Higher insulation resistance 1000 times more than PVC cables.

4. Higher resistance to moisture.

5. Better Resistance to surge currents.

6. Low Dielectric Losses.

7. Better resistance to chemicals.

8. Longer service life.

9. Comparatively higher cable operation temperature 90C and


short circuit temperature 250C.

B. Commercial Advantages:

1. Lower laying cost because of comparatively smaller diameter of cable and lighter
weight*.

2. Lower installation charges as the diameter of cable is comparatively lesser with


smaller bending radius, requiring less space requirement for laying of cables.

3. **One size lower cable can be used as compared to PVC insulated cable.

* Density of XLPE is lower than PVC


**For longer cable length voltage drop shall be considered
Polycab Cable of 33KV E 3 x 400 Sq.mm have been successfully type tested at
KEMA - Netherland (an internationally acclaimed Testing Laboratory).
BASEC CERTIFICATION OF OUR BUSINESS DEMONSTRATES OUR COMMITMENT TO NOT
ONLY THE QUALITY OF OUR PRODUCTS, BUT ALSO THE LEVEL OF OUR COMMITMENT
FOR CONTINUOUS IMPROVEMENT

Advantages of Polycab XLPE Cables

Higher Electrical Strength Retention


Higher Short Circuit Rating
Better Electrical, Mechanical &
Thermal Properties
Easy Jointing & Termination

Selection of Cables
Power Cables are generally selected considering the application. However, following
factors are important for selection of suitable cable construction required to transport
electrical energy from one end to the other.
1) Maximum operating voltage,
2) Fault Level,
3) Load to be carried,
4) Possible overloading duration & magnitude,
5) Route length and voltage drop.
6) Mode of installation considering installation environment such as ambient & ground
temperature chemical & physical properties of soil.
7) Flame retardant properties.
All sizes of POLYCAB XLPE cables are designed to standard operating conditions in India and
abroad. The standards adopted are considering the geographical/ climatical conditions
and general applications of power for utilities, distribution and generation purposes.
The cables are manufactured conforming to Indian & International cables specifications
for XLPE Insulated cables. Customer specific requirements can also be met.

Comparative current Rating and Short Circuit


Rating for XLPE Cable Vis--vis PVC Cables
Comparative Current Ratings of 650/1100 Volts Multicore heavy duty PVC Insulated Cables & XLPE Insulated Cables.
(3. 3.5 & 4 Core Unarmoured / Armoured PVC Sheathed Cables with Aluminium Conductor.)
Nominal Size of
cable

3, 3.5 & 4 Core PVC Insulated & Sheathed Cables as per IS - 1554
(Part-1) 1988

3, 3.5 & 4 Core XLPE Insulated & Sheathed Cables as per IS - 7098
(Part-1) 1988

In Ground

In Air

Approx Voltage Drop

In Ground

In Air

Approx Voltage Drop

Amp

Amp

Mv / amp / mtr

Amp

Amp

Mv / amp / mtr

Sq. mm
16

60

51

4.0

73

70

4.20

25

76

70

2.5

94

96

2.70

35

92

86

1.8

113

117

1.90

50

110

105

1.3

133

142

1.40

70

135

130

0.93

164

179

0.99

95

165

155

0.68

196

221

0.72

120

185

180

0.54

223

257

0.58

150

210

205

0.46

249

292

0.48

185

235

240

0.38

282

337

0.39

240

275

280

0.28

326

399

0.31

300

305

315

0.25

367

455

0.26

400

335

375

0.20

420

530

0.21

Comparison of Short Circuit Rating for 1 Second duration for


* PVC & XLPE Insulated Cables ** with Copper and Aluminium Conductors. (Current in kAmps)
Nominal Size

PVC Insulated

XLPE Insulated

Sq. mm

Copper

Aluminium

Copper

Aluminium

1.5

0.173

0.21

2.5

0.283

0.36

0.46

0.303

0.57

0.38

0.690

0.455

0.86

0.57

10

1.15

0.758

1.40

0.94

16

1.84

1.21

2.30

1.50

25

2.88

1.90

3.60

2.40

35

4.03

2.65

5.00

3.30

50

5.75

3.79

7.10

4.70

70

8.05

5.31

10.00

6.60

95

10.90

7.20

13.60

9.00

120

13.80

9.10

17.10

11.30

150

17.30

11.40

21.40

14.20

2) Max. Conductor Temperature During

185

21.30

14.02

26.40

17.50

240

27.60

18.20

34.30

22.60

Formula relating Short Circuit Rating with duration

300

34.50

22.80

42.90

28.30

400

46.00

30.40

57.10

37.70

500

57.50

38.00

71.40

47.20

630

72.50

47.25

90.00

59.40

800

92.00

60.00

114.30

75.50

1000

115.00

75.00

142.90

94.30

* PVC Type A Insulation as per IS-5831 84.


** PVC Cables as per IS-1554 (Part-1)-1988.
** XLPE Cables as per IS-7098 (Part-1)-1988.

1) Max. Conductor Temperature during


operation
PVC
XLPE

70C 90C
Short circuit.

160C

250C


It = I sh

t
Where
It = Short Circuit Rating for t Seconds.
t = Duration in seconds
Ish = Short Circuit rating for 1 second.

Technical Data
CAPACITANCE APPROXIMATE CAPACITANCE (Microfarads/ Km) 1.1 KV XLPE CABLES.
Nominal Area of
Conductor

Single Core
Unarmoured

Armoured

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

0.19
0.24
0.29
0.34
0.43
0.51
0.49
0.57
0.58
0.63
0.73
0.74
0.73
0.69
0.74
0.80
0.83
0.83
0.87
0.92
0.94

0.32
0.38
0.38
0.44
0.46
0.51
0.59
0.61
0.61
0.59
0.64
0.69
0.70
0.71
0.75
0.78
0.81

Two Core

Three, Three & Half and


Four Core

0.051
0.058
0.065
0.071
0.081
0.088
0.089
0.096
0.098
0.100
0.110
0.110
0.110
0.110
0.110
0.120
0.120
0.120
0.110
-

0.15
0.18
0.22
0.25
0.31
0.36
0.41
0.47
0.50
0.53
0.61
0.63
0.64
0.65
0.66
0.67
0.67
0.69
0.73
-

REACTANCE APPROXIMATE REACTANCE AT 50 HZ (Ohm/Km) 1.1 KV XLPE CABLES.


Single Core

Nominal Area of Conductor


1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Multi Core

Unarmoured

Armoured

0.155
0.142
0.132
0.123
0.114
0.108
0.103
0.0986
0.0937
0.0900
0.0865
0.0841
0.0839
0.0836
0.0813
0.0795
0.0787
0.0779
0.0785
0.0755
0.0752

0.134
0.125
0.120
0.114
0.108
0.102
0.100
0.0968
0.0941
0.0932
0.0900
0.0881
0.0873
0.0859
0.0843
0.0826
0.0825

0.107
0.0985
0.0927
0.0884
0.0837
0.0808
0.0805
0.0783
0.0750
0.0740
0.0724
0.0712
0.0716
0.0718
0.0710
0.0705
0.0704
0.0702
0.0698
-

Technical Data
Conductor Technical Information for Single Core and Multicore cables
conforming to IS-8130/1984 (Stranded - Class-2) Copper & Aluminium Conductors.
Nominal Size
of Conductor
Sq.mm
1.5*
2.5*
4*
6*
10*
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Minimum no. of wires


Non Compacted
CU.
3
3
7
7
7
7
7
7
19
19
19
37
37
37
61
61
61
61
91
91
91

ALU.
3
3
3
3
7
7
7
7
19
19
19
37
37
37
37
61
61
61
91
91
91

Max D.C. Resistance at 20C

A. C. Resistance at 90C

Compacted

Plain Copper

Aluminium

Plain Copper

Aluminium

Round/ Shaped
CU.
ALU.
6
6
6
6
6
6
6
6
6
12
12
15
15
18
15
18
15
30
30
34
30
34
30
53
53
53
53
53
53
53
53
53
53

Ohm/Km
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0469
0.0366
0.0283
0.0221
0.0176

Ohm/Km
18.10
12.10
7.41
4.61
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
0.0367
0.0291

Ohm/Km
15.50
9.48
5.90
3.94
2.34
1.47
0.930
0.671
0.495
0.343
0.247
0.196
0.159
0.127
0.0965
0.0769
0.0602
0.0468
0.0362
0.0283
0.0225

Ohm/Km
23.17
15.50
9.48
5.90
3.94
2.44
1.54
1.11
0.82
0.567
0.410
0.324
0.264
0.210
0.160
0.128
0.100
0.0774
0.0600
0.0470
0.0372

* These sizes can be manufactured with solid conductor having single strand

POLYCAB RECOMDATIONS FOR CURRENT RATINGS


1. The values given in the table are valid for on circuit in a three phase system under conditions specified. For grouping
cables rating factors must be used.
2. The current carrying capacities mentioned in POLYCAB technical data are intended as a guide, to assist operating
engineers in selecting cables for safety and reliability.
3. Basic assumptions and condition of installation:
*
Ambient ground Temperature : 30 C
*
Ambient air Temperature: 40 C
*
Depth of Cable Burial : 1.0 m
*
Thermal resistivity of soil : 150 C. Cm/W
4. Single Core Cables are installed as indicated in the table, spacing between cables in flat formation is as indicated.
5. For 3 and 4 core cables, it is usual to assume the same current carrying capacity for 4 core cables as for 3 core cables.
Our calculated values are based actually on 3 core cables. These values are suitable with enough accuracy also for 4
cables in most cases. Only for large 4 core cables in air the values are too conservative, due to the large cable surface
and consequent high heat dissipation factor.
6. To obtain the maximum current carrying capacity of a cable operating at different conditions from the standard.
Various rating factors are to be multiplied as follows:

Ia = K Is (in Amperes)

Where
Ia = Current Rating at actual Operating Conditions (amperes)
Is = Current Rating at Standard Operating Conditions (amperes)
K = Rating Factor as applicable

Solid

Stranded

Stranded

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

--do--

10

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

800

1000

2.8

2.6

2.4

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Minimum
Thickness
of PVC
Inner
Sheath

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

mm

52.0

46.0

40.0

36.0

33.0

28.5

26.0

23.5

21.5

19.0

17.5

16.0

14.0

13.0

12.0

10.0

9.5

9.0

8.5

8.0

8.0

7.5

mm

Nominal Approx.
ThickOverall
ness
Diamof PVC eter of
Outer
Cable.
Sheath

3350

2730

2100

1650

1385

1075

900

710

600

470

385

310

240

180

155

115

90

80

75

70

65

60

Kgs./Km

4 x 0.80
4 x 0.80

3.3

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

mm

Nominal
Dimension of
Aluminium Flat
Strip.

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

mm

Minimum
Thickness
of PVC
Outer
Sheath

54.0

46.5

40.5

37.5

34.0

30.0

27.5

25.0

23.0

22.0

21.0

mm

Approx.
Overall
Diameter of
Cable.

3963

3150

2525

2090

1725

1350

1100

900

750

660

560

Kgs./Km

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

mm

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

mm

Minimum
Thickness
of PVC
Outer
Sheath

58.0

49.5

43.0

39.5

36.5

31.5

29.0

26.5

24.5

23.5

22.0

19.0

17.0

15.0

14.0

13.0

mm

Approx.
Overall
Diameter of
Cable.

4475

3450

2800

2300

1925

1475

1215

1000

850

745

640

480

380

310

260

220

Kgs./Km

Approx.
Weight
of
Cable.

Round Wire Armoured Cable

Approx. Nominal
Weight Dimenof
sion of
Cable.
Aluminium
Round
Wire.

Formed Wire/ Strip Armoured Cable

3.1

2.8

2.6

2.4

2.1

2.0

1.9

1.7

1.5

1.4

1.4

1.3

1.2

1.2

1.0

1.0

1.0

mm

Nominal
Thickness
Approx.
Weight of XLPE
insulaof
tion
for
Cable.
Armoured
Cable

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Solid

Stranded

Stranded

0.7

0.7

mm

Solid

Sq.mm.

Nominal Form of Nominal


Size of Conductor ThickConduc- Circular
ness of
tor
XLPE
Insulation for
U/A

650/1100 VOLTS

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-1 POLYCAB SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED,

650

600

557

490

431

376

332

286

253

225

198

166

135

114

96

76

59

59

44

44

36

36

Amps.

In
Ground.

1050

890

814

693

596

501

433

360

309

268

230

187

150

121

98

73

53

53

39

39

31

31

Amps.

In Air

Current Rating.

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

*Normal
Delivery
Length.

WEIGHT & DIMENSIONS

Weight, Dimension data &


Current carrying capacity of cables

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

800

1000

2.8

2.6

2.4

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Minimum
Thickness
of PVC
Inner
Sheath

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

mm

52.0

46.0

40.0

36.0

33.0

28.5

26.0

23.5

21.5

19.0

17.5

16.0

14.0

13.0

12.0

10.0

9.5

8.5

8.0

8.0

7.5

mm

Nominal Approx.
ThickOverall
ness
Diamof PVC eter of
Outer
Cable.
Sheath

9850

7900

6250

5020

4035

3050

2450

1900

1550

1250

1010

750

550

420

325

220

170

125

115

95

91

Kgs./Km

3.3

3.1

2.8

2.6

2.4

2.1

2.0

1.9

1.7

1.5

1.4

1.4

1.3

1.2

1.2

1.0

1.0

mm

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

mm

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

mm

54.0

46.5

40.5

37.5

34.0

30.0

27.5

25.0

23.0

22.0

21.0

mm

10150

8100

6425

5180

4200

3200

2580

2040

1680

1400

1150

Kgs./Km

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

mm

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

mm

58.0

49.5

43.0

39.5

36.5

31.5

29.0

26.5

24.5

23.5

22.0

19.0

17.0

16.0

14.0

13.0

12.0

mm

10660

8400

6700

5400

4400

3325

2700

2140

1780

1485

1325

910

690

525

415

315

245

Kgs./Km

Formed Wire/ Strip Armoured Cable


Round Wire Armoured Cable
Nominal
ThickApprox. Approx.
Approx. Approx. Nominal MiniApprox.
Nominal MiniOverall Weight
Weight ness of Dimenmum
Overall Weight Dimension mum
XLPE
Diamof
of AluThickDiamof
of
sion of
Thickinsula- Alumineter of
Cable.
ness
eter of
Cable. minium
ness
Cable.
tion for ium Flat of PVC
Cable.
Round
of PVC
Cable.
ArStrip.
Outer
Wire.
Outer
moured
Sheath
Sheath
Cable

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Solid

Stranded

Stranded

0.7

0.7

mm

Solid

Sq.mm.

Nominal Form of Nominal


Size of Conductor ThickConduc- Circular
ness of
tor
XLPE
Insulation for
U/A

650/1100 VOLTS

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-2 POLYCAB SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED,

723

660

570

564

480

450

414

1063

945

825

708

660

570

510

384
444

336

336

294

246

198

156

132

98

72

53

53

42

42

Amps.

In Air

366

300

264

228

186

156

132

102

78

59

59

47

47

Amps.

In
Ground.

Current Rating.

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

*Normal
Delivery
Length.

WEIGHT & DIMENSIONS

Weight, Dimension data &


Current carrying capacity of cables

10

Stranded

Stranded

500

630

2.4

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

mm

Minimum
Thickness
of PVC
Inner
Sheath

3.6

3.4

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

mm

Nominal
Thickness
of PVC
Outer
Sheath

61.5

55.5

49.0

43.5

39.5

35.5

32.0

28.5

26.5

23.0

21.0

19.0

17.0

14.0

16.0

15.0

14.0

13.5

13.0

12.5

mm

5000

4000

3100

2360

1900

1510

1215

1050

900

675

510

410

330

225

225

205

180

170

150

140

Kgs./Km

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

300

Stranded

240

400

Stranded

Stranded

150

Stranded

120

185

Stranded

Stranded

Stranded

50

70

Stranded

35

95

Stranded

Stranded

16

25

Stranded

10

0.7

Stranded

Solid

10

0.7

Solid

0.7

0.7

Solid

Stranded

mm

mm

Sq.mm.

Nominal
Thickness of
XLPE
Insulation

Form of
Conductor
Circular
Shaped

Nominal
Size of
Conductor

650/1100 VOLTS

2.52
2.68

-do-

2.36

2.04

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Minimum
Thickness
of PVC
Outer
Sheath

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Nominal
Dimension of
GI Flat
Strip.

62.5

56.5

51.0

45.5

41.0

37.0

34.0

30.5

28.0

25.5

22.5

20.0

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

6050

5000

4000

3200

2600

2200

1750

1500

1300

1050

820

690

600

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

Formed Wire/ Strip Armoured Cable

3.15

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

1.40

1.40

mm

Nominal
Dimension
of GI
Round
Wire.

2.84

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

mm

Minimum
Thickness
of PVC
Outer
Sheath

67.5

61.5

54.4

49.0

45.0

40.0

36.0

33.0

30.5

27.0

24.0

22.0

20.0

17.0

18.0

17.0

16.5

15.5

15.5

14.5

mm

Approx.
Overall
Diameter
of Cable.

8560

7000

5300

4400

3700

2750

2250

2000

1750

1325

1050

910

790

570

565

545

485

470

430

400

Kgs./Km

592

523

481

444

400

344

300

262

238

200

169

138

112

88

69

69

50

50

40

40

Amps.

786

678

525

500

500

500

500

500

406
456

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

344

300

262

231

188

156

124

98

74

59

59

44

44

34

34

Amps.

*Normal
Delivery
Length.

WEIGHT AND DIMENSIONS


Current Rating.

Approx.
In
In Air
Weight Ground.
of Cable.

Round Wire Armoured Cable

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-3 POLYCAB TWO CORE ALUMINIUM CONDUCTOR, XLPE INSULATED,

Weight, Dimension data &


Current carrying capacity of cables

Stranded

400

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

mm

Nominal
Thickness of
XLPE
Insulation

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

mm

Minimum
Thickness
of PVC
Inner
Sheath

43.5
49.0

3.0

39.5

35.5

32.0

28.5

26.5

23.0

21.0

19.0

17.0

14.0

16.0

14.0

13.5

13.0

12.5

mm

8050

6075

4870

3800

3070

2535

2075

1540

1120

840

640

425

300

225

210

175

165

Kgs./Km

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

mm

Nominal
Thickness
of PVC
Outer
Sheath

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

240

Stranded

185

300

Stranded

Stranded

120

Stranded

95

150

Stranded

Stranded

Stranded

35

50

Stranded

25

70

Stranded

Stranded

10

Stranded

16

Stranded

Solid

Solid

mm

Sq.mm.

Form of
Conductor
Circular
Shaped

Nominal
Size of
Conductor

650 / 1100 VOLTS

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

2.36

2.04

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

51.0

45.5

41.0

37.0

34.0

30.5

28.0

25.5

22.5

20.0

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

8950

6910

5575

4490

3600

2985

2475

1910

1435

1025

910

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

Nominal Minimum Approx. Approx.


DimenThickOverall
Weight
sion of
ness of Diameter of Cable.
GI Flat PVC Outer of Cable.
Strip.
Sheath

Formed Wire/ Strip Armoured Cable

2.5

2.5

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

mm

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

mm

54.4

49.0

45.0

40.0

36.0

33.0

30.5

27.0

24.0

22.0

20.0

17.0

18.0

16.5

15.5

15.5

14.5

mm

10250

9010

7370

5040

4100

3485

2925

2200

1670

1350

1100

770

740

610

564

525

480

Kgs./Km

612

562

506

438

388

344

300

256

206

175

144

113

88

63

63

51

51

Amps.

662

581

512

438

381

331

288

244

194

150

131

98

75

56

56

44

44

Amps.

In Air

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length.

WEIGHT AND DIMENSIONS


Current Rating.

Nominal Minimum Approx. Approx.


In
DimenThickOverall
Weight Ground.
ness of Diameter of Cable.
sion
of GI PVC Outer of Cable.
Round
Sheath
Wire.

Round Wire Armoured Cable

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-4 POLYCAB TWO CORE COPPER CONDUCTOR, XLPE INSULATED,

Weight, Dimension data &


Current carrying capacity of cables

11

12

Stranded

500

630

2.4

2.2

2.0

0.7

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

mm

Minimum
Thickness
of PVC
Inner
Sheath

3.8

3.6

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

mm

72.0

66.0

59.5

51.5

48.5

43.5

38.5

34.5

32.5

29.0

24.5

21.5

20.0

18.0

18.0

17.0

16.0

15.5

15.5

14.0

mm

7550

6000

4760

3750

3000

2380

1900

1525

1250

990

700

575

460

310

230

220

190

170

160

140

Kgs./Km

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

Unarmoured Cable
Nominal
Thickness
of PVC
Outer
Sheath

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

400

1.8

Stranded

Stranded

300

1.7

Stranded

240

1.4

1.6

Stranded

1.2

Stranded

Stranded

120

1.1

150

Stranded

95

1.1

1.0

0.9

0.9

0.7

0.7

0.7

185

Stranded

Stranded

50

Stranded

35

70

Stranded

Stranded

16

25

Stranded

10

0.7

Stranded

Solid

10

0.7

Solid

0.7

0.7

Solid

Stranded

mm

mm

Sq.mm.

Nominal
Thickness of
XLPE
Insulation

Form of
Conductor
Circular
Shaped

Nominal
Size of
Conductor

650/1100 VOLTS

2.68
2.84

-do-

2.52

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

73.0

67.0

58.5

53.0

49.0

44.5

40.5

35.5

33.5

30.0

25.5

23.0

20.5

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

8700

6900

5700

4500

3700

2500

2100

2050

1735

1425

1100

900

770

530

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

Nominal Minimum Approx. Approx.


DimenThickOverall
Weight
sion of
ness of Diameter of Cable.
GI Flat PVC Outer of Cable.
Strip.
Sheath

Formed Wire/ Strip Armoured Cable

4.00

3.15

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

1.40

mm

Nominal
Dimension
of GI
Round
Wire.

3.00

2.84

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

mm

Minimum
Thickness
of PVC
Outer
Sheath

78.0

73.0

65.0

57.5

53.0

48.5

43.5

39.5

37.5

32.0

27.5

25.0

23.0

21.0

19.0

18.0

17.0

16.0

16.0

15.0

mm

12500

9550

7900

5900

5100

4200

3200

2700

2300

1950

1400

1150

990

750

680

640

580

530

510

460

Kgs./Km

529

470

418

367

326

282

249

223

196

164

133

113

94

73

57

57

43

43

34

34

Amps.

707

612

530

455

399

337

292

257

221

179

142

117

96

70

67

67

50

50

31

31

Amps.

In Air

Current Rating.

250

250

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

*Normal
Delivery
Length.

WEIGHT AND DIMENSIONS


Approx. Approx.
In
Overall
Weight Ground.
Diameter of Cable.
of Cable.

Round Wire Armoured Cable

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-5 POLYCAB THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED,

Weight, Dimension data &


Current carrying capacity of cables

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

mm

Minimum
Thickness
of PVC
Inner
Sheath

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

mm

Nominal
Thickness
of PVC
Outer
Sheath

59.5

51.5

48.5

43.5

38.5

34.5

32.5

29.0

24.5

21.5

20.0

18.0

18.0

16.0

15.5

15.5

14.0

mm

12200

9310

7450

5810

4760

3750

3010

2290

1620

1225

920

425

415

300

280

235

210

Kgs./Km

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

2.0

Stranded

400

1.7

1.8

Stranded

Stranded

1.6

240

Stranded

185

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

mm

Nominal
Thickness of
XLPE
Insulation

300

Stranded

Stranded

120

Stranded

95

150

Stranded

Stranded

50

Stranded

35

70

Stranded

Stranded

Stranded

10

16

Stranded

25

Stranded

Solid

Solid

mm

Sq.mm.

Form of
Conductor
Circular
Shaped

Nominal
Size of
Conductor

650/1100 VOLTS

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

mm

2.52

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

-NA-

-NA-

-NA-

-NA-

-NA-

mm

58.5

53.0

49.0

44.5

40.5

35.5

33.5

30.0

25.5

23.0

20.5

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

mm

13125

10060

8150

6385

5280

4320

3500

2720

2020

1550

1235

825

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

Nominal Minimum Approx. Approx.


DimenThickOverall
Weight
sion of
ness of Diameter of Cable.
GI Flat PVC Outer of Cable.
Strip.
Sheath

Formed Wire/ Strip Armoured Cable

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

mm

Nominal
Dimension
of GI
Round
Wire.

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

mm

Minimum
Thickness
of PVC
Outer
Sheath

65.0

57.5

53.0

48.5

43.5

39.5

37.5

32.0

27.5

25.0

23.0

21.0

19.0

17.0

16.0

16.0

15.0

mm

15320

11460

9550

7630

5980

4920

4060

3250

2320

1800

1450

1040

865

680

640

580

530

Kgs./Km

510

462

414

360

324

288

252

210

174

144

119

92

72

54

54

43

43

Amps.

546

480

426

366

318

276

240

198

162

132

108

79

62

47

47

36

36

Amps.

In Air

Current Rating.

250

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

*Normal
Delivery
Length.

WEIGHT AND DIMENSIONS


Approx. Approx.
In
Overall
Weight Ground.
Diameter of Cable.
of Cable.

Round Wire Armoured Cable

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-6 POLYCAB THREE CORE COPPER CONDUCTOR, XLPE INSULATED,

Weight, Dimension data &


Current carrying capacity of cables

13

14

185/95

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

mm

1.7

1.6

1.4

1.2

1.1

1.1

1.1

1.0

0.9

0.9

0.7

0.7

mm

Nominal
Thickness of
XLPE Insulation
Main / Neutral

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

mm

Minimum
Thickness
of PVC
Inner
Sheath

3.6

3.4

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

mm

Nominal
Thickness
of PVC
Outer
Sheath

72.5

64.0

56.0

52.5

46.5

41.0

37.5

35.0

31.0

27.5

24.0

22.0

mm

Approx.
Overall
Diameter of
Cable.

-do-do-

6500

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.80

mm

Nominal
Dimension of
GI Flat
Strip.

2.68

2.52

2.20

2.04

1.88

1.72

1.72

1.56

1.56

1.40

1.40

1.40

mm

Minimum
Thickness
of PVC
Outer
Sheath

73.5

65.0

57.0

53.5

47.5

42.0

39.0

36.0

32.0

28.0

25.0

23.0

mm

Approx.
Overall
Diameter of
Cable.

7600

6150

4950

4100

3250

2650

2300

1900

1600

1240

980

850

Kgs./Km

Approx.
Weight
of
Cable.

Formed Wire/ Strip Armoured Cable

5250

4000

3200

2550

2000

1650

1400

1100

800

625

525

Kgs./Km

Approx.
Weight
of
Cable.

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

150/70

500/240

Stranded

120/70

Stranded

Stranded

95/50

400/185

Stranded

70/35

Stranded

Stranded

50/25

Stranded

Stranded

35/16

240/120

Stranded

25/16

300/150

mm

Stranded

Sq.mm.

Form of
Conductor
Shaped

Nominal
Size of
Conductors

650/1100 VOLTS

3.15

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

mm

Nominal
Dimension
of GI
Round
Wire.

2.84

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

mm

Minimum
Thickness
of PVC
Outer
Sheath

77.0

70.0

61.0

56.0

50.0

45.0

41.0

38.0

34.0

29.5

26.5

25.5

mm

Approx.
Overall
Diameter of
Cable.

WEIGHT AND DIMENSIONS

10000

8300

6400

5450

4500

3350

2800

2450

2050

1500

1200

1050

470

418

367

326

282

249

223

196

164

133

113

94

612

530

455

399

337

292

257

221

179

142

117

96

Kgs./Km Amps. Amps.

250

500

500

500

500

500

500

500

500

1000

1000

1000

Mtrs.

Current Rating. *Normal


Approx.
In
In Air Delivery
Length.
Weight Ground
of
Cable.

Round Wire Armoured Cable

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-7 POLYCAB THREE AND HALF CORE ALUMINIUM CONDUCTOR, XLPE INSULATED

Weight, Dimension data &


Current carrying capacity of cables

mm

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Sq.mm.

25/16

35/16

50/25

70/35

95/50

120/70

150/70

185/95

240/120

300/150

400/185

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

mm

1.6

1.4

1.2

1.1

1.1

1.1

1.0

0.9

0.9

0.7

0.7

mm

Nominal
Thickness of
XLPE Insulation
Main / Neutral

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

mm

Minimum
Thickness
of PVC
Inner
Sheath

3.4

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

mm

Nominal
Thickness
of PVC
Outer
Sheath

65.0

57.0

54.0

48.0

43.0

39.0

35.0

31.0

27.5

24.0

22.0

mm

Approx.
Overall
Diameter of
Cable.

13820

10500

8400

6575

5220

4315

3475

2620

1875

1370

1080

Kgs./Km

Approx.
Weight
of
Cable.

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Form of
Conductor
Shaped

Nominal
Size of
Conductors

650/1100 VOLTS

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.80

mm

Nominal
Dimension of
GI Flat
Strip.

2.52

2.20

2.04

1.88

1.72

1.72

1.56

1.56

1.40

1.40

1.40

mm

Minimum
Thickness
of PVC
Outer
Sheath

66.0

58.0

55.0

50.0

44.0

40.0

36.0

32.0

28.0

25.0

23.0

mm

Approx.
Overall
Diameter of
Cable.

14720

11500

9300

7275

5870

4960

8975

3110

2325

1725

1410

Kgs./Km

Approx.
Weight
of
Cable.

Formed Wire/ Strip Armoured Cable

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

mm

Nominal
Dimension
of GI
Round
Wire.

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

mm

Minimum
Thickness
of PVC
Outer
Sheath

70.0

61.0

56.0

50.0

45.0

41.0

37.5

34.0

29.0

26.0

24.0

mm

Approx.
Overall
Diameter of
Cable.

WEIGHT AND DIMENSIONS

16875

12400

10650

8520

6570

5460

4525

3560

2580

1950

1610

510

462

414

360

324

288

252

210

174

144

119

546

480

426

366

318

276

240

198

162

132

108

Kgs./Km Amps. Amps.

250

500

500

500

500

500

500

500

1000

1000

1000

Mtrs.

Current Rating. *Normal


Approx.
In
In Air Delivery
Length.
Weight Ground
of
Cable.

Round Wire Armoured Cable

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-8 POLYCAB THREE AND HALF CORE COPPER CONDUCTOR, XLPE INSULATED

Weight, Dimension data &


Current carrying capacity of cables

15

16

Stranded

Stranded

Stranded

240

300

400

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.6

0.5

0.5

0.5

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

mm

3.6

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

mm

65.5

58.0

52.5

46.5

42.0

37.5

33.5

30.5

26.0

23.5

21.0

17.5

18.5

18.0

17.5

16.5

16.0

15.0

mm

6000

4600

3700

2800

2280

1850

1530

1200

875

680

550

350

260

250

215

200

180

160

Kgs./Km

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

150

Stranded

120

185

Stranded

Stranded

70

Stranded

50

95

Stranded

Stranded

25

Stranded

16

35

Solid

Stranded

10

Stranded

10

Stranded

Solid

Solid

mm

2.36
2.68

-do-

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

66.5

59.5

54.0

48.0

43.5

39.0

35.0

32.0

28.0

25.0

23.0

20.0

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

7000

5600

4700

3650

3000

2600

2100

1700

1280

1050

940

715

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

3.15

3.15

2.50

2.50

2.50

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

1.40

mm

2.84

2.52

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

mm

Minimum
Thickness
of PVC
Outer
Sheath

71.5

64.5

57.5

52.0

47.0

42.0

38.0

34.0

29.5

26.5

25.0

21.0

20.5

19.0

18.5

17.5

17.5

16.5

mm

9500

7850

6050

5000

4175

3250

2775

2175

1640

1325

1150

895

765

700

625

580

560

510

Kgs./Km

418

367

326

282

249

223

196

164

133

113

94

73

57

57

43

43

34

34

Amps.

530

455

399

337

292

257

221

179

142

117

96

70

67

67

50

50

31

31

Amps.

Approx. Approx.
In
In Air
Overall
Weight Ground.
Diameter of Cable.
of Cable.

Round Wire Armoured Cable

Approx. Approx. Nominal


Overall
Weight
DimenDiameter of Cable. sion of
of Cable.
GIRound
Wire.

500

500

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

Mtrs.

*Normal
Delivery
Length.

mm

Minimum
Thickness
of PVC
Outer
Sheath

Formed Wire/ Strip Armoured Cable


Nominal
Dimension of
GI Flat
Strip.

Sq.mm.

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

Unarmoured Cable
Nominal
Thickness
of PVC
Outer
Sheath

Current Rating.

Minimum
Thickness
of PVC
Inner
Sheath

Form of
Conductor
Circular
Shaped

Nominal
Size of
Conductor

Nominal
Thickness of
XLPE
Insulation

WEIGHT AND DIMENSIONS

650/1100 VOLTS

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-9 POLYCAB FOUR CORE ALUMINIUM CONDUCTOR, XLPE INSULATED,

Weight, Dimension data &


Current carrying capacity of cables

Stranded

Stranded

240

300

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

mm

Nominal
Thickness of
XLPE
Insulation

0.7

0.6

0.5

0.5

0.5

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

mm

Minimum
Thickness
of PVC
Inner
Sheath

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

mm

Nominal
Thickness
of PVC
Outer
Sheath

58.0

52.5

46.5

42.0

37.5

33.5

30.5

26.0

23.5

21.0

17.5

18.5

17.5

16.5

16.0

15.0

mm

12025

9650

7380

6000

4825

3880

2925

2110

1550

1170

750

510

365

350

280

260

Kgs./Km

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

Unarmoured Cable

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

150

Stranded

120

185

Stranded

Stranded

Stranded

50

70

Stranded

35

95

Stranded

Stranded

16

Stranded

10

25

Solid

Stranded

Stranded

mm

Solid

Sq.mm.

Form of
Conductor
Circular
Shaped

Nominal
Size of
Conductor

650/1100 VOLTS

2.20
2.36

-do-

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Minimum
Thickness
of PVC
Outer
Sheath

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Nominal
Dimension of
GI Flat
Strip.

59.5

54.0

48.0

43.5

39.0

35.0

32.0

28.0

25.0

23.0

20.0

-NA-

-NA-

-NA-

-NA-

-NA-

mm

13025

10340

8225

6710

5575

4450

3430

2510

1915

1520

1050

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

Approx. Approx.
Overall
Weight
Diameter of Cable.
of Cable.

Formed Wire/ Strip Armoured Cable

3.15

2.50

2.50

2.50

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

mm

Nominal
Dimension
of GI
Round
Wire.

2.52

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

mm

Minimum
Thickness
of PVC
Outer
Sheath
mm

64.5

57.5

52.0

47.0

42.0

38.0

34.0

29.5

26.5

25.0

21.0

20.5

18.5

17.5

17.5

16.5

15275

12000

9580

7890

6225

5125

3900

2875

2190

1770

1275

1010

775

730

660

610

Kgs./Km

426
480

462

366

318

276

240

198

162

132

108

79

62

47

47

36

36

Amps.

414

360

324

288

252

210

174

144

119

92

72

54

54

43

43

Amps.

In Air

Current Rating.

250

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

Mtrs.

*NormalDelivery
Length.

WEIGHT AND DIMENSIONS


Approx. Approx.
In
Overall
Weight Ground.
Diameter of Cable.
of Cable.

Round Wire Armoured Cable

UNARMOURED & ARMOURED CABLE CONFORMING TO IS 7098 PART-1/1988

TABLE-10 POLYCAB FOUR CORE COPPER CONDUCTOR, XLPE INSULATED,

Weight, Dimension data &


Current carrying capacity of cables

17

18

0.7

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

10

12

14

16

19

21

24

27

30

33

37

44

52

61

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

mm

mm

2.2

2.0
31.0

29.0

28.0

25.0

2.0

2.0

24.0

23.5

23.0

22.5

20.5

19.5

18.5

18.0

17.5

17.0

15.5

14.5

13.5

13.5

12.5

11.5

10.5

10.0

2.0

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

mm

1500

1300

1150

975

910

820

750

665

600

540

475

430

390

340

315

280

260

250

225

200

160

140

Kgs./Km

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.80

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

1.56

1.56

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

32.0

30.5

28.5

26.0

25.0

24.0

23.5

23.0

21.0

20.0

19.0

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Nominal
MiniApprox.
Dimen- mumThick- Overall
sion of
ness of Diameter
GI Flat PVC Outer of Cable.
Strip.
Sheath

1950

1700

1500

1325

1225

1125

1050

1000

900

815

750

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

Approx.
Weight of
Cable.

Formed Wire/ Strip Armoured Cable

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

mm

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.24

mm

Nominal Minimum
Dimen- Thickness
sion of
of PVC
GI Round
Outer
Wire.
Sheath

2050
2550

34.5

1850

1550

1475

1400

1330

1250

1150

1010

925

825

720

655

630

580

520

500

465

415

390

370

Kgs./Km

Approx.
Weight of
Cable.

32.0

30.5

28.0

27.0

26.0

25.5

25.0

23.0

22.0

21.0

20.0

19.0

18.5

17.5

16.5

15.5

15.5

14.5

13.5

13.0

12.5

mm

Approx.
Overall
Diameter
of Cable.

Round Wire Armoured Cable

$ The Weight and Dimensions of Cables with Stranded conductor will be comparatively more than that of Solid conductor,whereas all other parameters are same..
The above data is approximate and subject to manufacturing tolerance.
* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

mm

Nominal Minimum
Unarmoured Cable
Thickness Thickness Nominal
Approx.
Approx.
of XLPE
of PVC Thickness Overall Weight of
InsulaInner
of PVC
Diameter
Cable.
tion
Sheath
Outer
of Cable.
Sheath

No. s

Number
of Cores

Solid & Stranded $

Unarmoured, Armoured Cable conforming to IS 7098 PART - 1/1988

10

11

11

12

12

13

13

14

15

16

16

17

18

19

20

21

22

24

25

25

33

Amps.

In
Ground.

10

10

11

11

12

12

13

14

14

15

16

17

18

18

19

21

22

22

29

Amps.

In Air

Current Rating.

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

*Normal
Delivery
Length.

WEIGHT AND DIMENSIONS

TABLE-11 POLYCAB 650/1100 Volts Multicore Control Cable with Solid Copper Conductor of size 1.5 Sq.mm XLPE Insulated

Weight, Dimension data &


Current carrying capacity of cables

0.3

0.3

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

10

12

14

16

19

21

24

27

30

33

37

44

52

61

2.2

2.2

2.2

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

mm

35.0

33.5

32.0
2150

1950

1650

1250
1350

27.0

1150

1050

950

860

770

680

625

550

475

450

400

360

340

300

260

220

185

Kgs./Km

28.0

26.0

25.5

24.5

22.5

21.5

20.5

19.0

18.0

17.5

16.5

16.0

15.0

15.0

14.0

13.0

12.0

11.5

mm

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.24

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

36.0

34.5

33.0

29.5

28.5

27.5

26.5

25.5

23.5

22.5

21.5

20.0

19.5

19.0

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

mm

Minimum Approx.
ThickOverall
ness of Diameter
PVC Outer of Cable.
Sheath

2625

2350

2100

1710

1630

1550

1350

1250

1140

1025

920

850

760

700

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Kgs./Km

Approx.
Weight of
Cable.

Formed Wire/ Strip Armoured Cable


Nominal
Dimension of
GI Flat
Strip.

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

mm

1.56

1.56

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

1.24

mm

39.0

37.5

35.5

31.5

30.5

29.0

28.5

27.5

25.5

24.5

23.5

22.0

21.5

21.0

19.5

18.0

16.5

16.5

15.5

14.5

14.0

13.5

mm

Approx.
Overall
Diameter
of Cable.

3400

2900

2600

2080

1950

1760

1625

1500

1350

1250

1160

1050

975

875

800

700

625

600

525

500

425

380

Kgs./Km

Approx.
Weight of
Cable.

Round Wire Armoured Cable


Nominal Minimum
Dimen- Thickness
sion of
of PVC
GI Round
Outer
Wire.
Sheath

$ The Weight and Dimensions of Cables with Stranded conductor will be comparatively more than that of Solid conductor,whereas all other parameters are same..
The above data is approximate and subject to manufacturing tolerance.
* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.7

mm

mm

Nominal Minimum
Unarmoured Cable
Thickness Thickness Nominal Approx.
Approx.
of XLPE
of PVC Thickness Overall Weight of
InsulaInner
of PVC
Diameter
Cable.
tion
Sheath
Outer
of Cable.
Sheath

No. s

Number
of Cores

Solid & Stranded $

Unarmoured, Armoured Cable conforming to IS 7098 PART - 1/1988

12

13

14

15

15

16

16

17

18

19

20

21

22

24

25

26

27

29

31

34

34

39

Amps.

In
Ground.

11

12

12

13

14

14

16

16

16

17

18

19

20

21

22

24

25

26

28

30

30

32

Amps.

In Air

Current Rating.

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

*Normal
Delivery
Length.

WEIGHT AND DIMENSIONS

TABLE-12 POLYCAB 650/1100 Volts Multicore Control Cable with Solid Copper Conductor of size 2.5 Sq.mmXLPE Insulated

Weight, Dimension data &


Current carrying capacity of cables

19

Rating Factors
1 ) F O R A I R A N D GRO UND TE MPE R ATU RE
A. Rating factors for variation in ambient air temperature
Ambient Temp (C)

25

30

35

40

45

50

Rating Factors

1.14

1.10

1.04

1.00

0.95

0.90

B. Rating factors for variation in ground temperature


Ground Temp (C)

15

20

25

30

35

40

Rating Factors

1.12

1.08

1.03

1.00

0.96

0.91

2 ) F O R D EP T H O F LAYING (CA BLE S LAID DIRECT IN T HE GROUND) .


Depth of laying

Size

Cm

Upto 25 mm

Above 25 mm2 Upto 300 mm2

Above 300 mm2

75

1.0

1.00

1.00

90

0.99

0.98

0.97

105

0.98

0.97

0.96

120

0.97

0.96

0.95

150

0.96

0.94

0.92

180 or more

0.95

0.93

0.91

3 ) F O R VA R I AT IO N IN THE R MA L R E S IST IVIT Y OF SOIL


(T WI N A N D M ULTICO R E CA BLE S L AID DIRECT IN T HE GROUND) .

20

Two cables touching for values of Thermal Resistivity of soil in C cm / W

Nominal area of
conductor mm2

100

120

150

200

250

300

1.5

1.10

1.05

1.00

0.92

0.86

0.81

2.5

1.10

1.05

1.00

0.92

0.86

0.81

1.10

1.05

1.00

0.92

0.86

0.81

1.10

1.05

1.00

0.92

0.86

0.81

10

1.10

1.06

1.00

0.92

0.85

0.80

16

1.12

1.06

1.00

0.91

0.84

0.79

25

1.14

1.08

1.00

0.91

0.84

0.78

35

1.15

1.08

1.00

0.91

0.84

0.77

50

1.15

1.08

1.00

0.91

0.84

0.77

70

1.15

1.08

1.00

0.90

0.83

0.76

95

1.15

1.08

1.00

0.90

0.83

0.76

120

1.17

1.09

1.00

0.90

0.82

0.76

150

1.17

1.09

1.00

0.90

0.82

0.75

185

1.18

1.09

1.00

0.89

0.81

0.75

240

1.18

1.09

1.00

0.89

0.81

0.75

300

1.18

1.09

1.00

0.89

0.81

0.75

400

1.19

1.10

1.00

0.89

0.81

0.75

Group Rating Factors


F O R S I N G L E C O R E CA BLE S
A) Cables laid direct in the ground in horizontal formation.
No. of Trefoils in Group

Distance between Trefoils


Touching

15 cm

30 cm

45 cm

0.78

0.81

0.85

0.88

0.68

0.71

0.77

0.81

0.61

0.65

0.72

0.76

0.56

0.61

0.68

0.73

B) Cables laid in ducts in horizontal formation.


No. of Trefoils in Group

Distance between Trefoils


Touching

45 cm

60 cm

0.87

0.90

0.91

0.79

0.83

0.86

0.74

0.79

0.82

0.71

0.76

0.80

C) Cables laid on racks / Trays in covered trench with having restricted air circulation, Trefoils are separated by two cable
diameter horizontally and the trays are in tiers having 30 cm distance.
No. racks / trays in tiers

No. of Trefoils in Horizontal Formation


1

0.95

0.90

0.88

0.90

0.85

0.83

0.88

0.83

0.81

0.86

0.81

0.79

D) as above C. but cables laid in open air.


No. racks / trays in tiers

No. of Trefoils in Horizontal Formation


1

0.98

0.96

0.95

0.93

0.94

0.92

0.93

0.90

21

Group Rating Factors


F O R M U LT I C O R E CA BLE S
A) Cables laid on cable trays exposed to air, the cables spaced by one cable diameter and trays are in tiers spaced by
30 cm. The clearance between the wall and the cable is 25 mm.
No. of cables trays in
tier

No. of Cables per Tray


1

0.98

0.96

0.93

0.92

0.95

0.93

0.90

0.89

0.94

0.92

0.89

0.88

0.93

0.90

0.87

0.86

B) Cables laid inside concrete trench with removable covers on cable trays having restricted circulation. The cables spaced
by one cable diameter and trays are in tiers spaced by 30 cm. The clearance of the cable from the wall is 25 mm.
No. of cables trays in
tier

No. of Cables per Tray


1

0.95

0.90

0.88

0.85

0.84

0.90

0.85

0.83

0.81

0.80

0.88

0.83

0.81

0.79

0.78

0.86

0.81

0.79

0.77

0.76

C) Cables laid on cable trays exposed to air, the cable touching and trays are in tiers spaced by 30 cm. The clearance
between the wall and the cable is 25 mm.
No. of Cables per Tray

No. of cables trays in


tier

0.84

0.80

0.75

0.73

0.80

0.76

0.71

0.69

0.78

0.74

0.70

0.68

0.76

0.72

0.68

0.66

D) Cables laid direct in ground in horizontal formation.


No. of cables in Group

Distance of Cables
Touching

15 cm

30 cm

45 cm

0.79

0.82

0.87

0.90

0.69

0.75

0.79

0.83

0.62

0.69

0.74

0.79

0.58

0.65

0.72

0.76

0.54

0.61

0.69

0.75

E) Cables laid in single way ducts / pipes in horizontal formation.


No. of cables in Group

22

Distance of Cables
Touching

30 cm

45 cm

60 cm

0.88

0.90

0.92

0.94

0.82

0.84

0.87

0.89

0.77

0.80

0.84

0.87

0.74

0.78

0.82

0.85

0.71

0.76

0.81

0.84

Handling, Storage and Laying of Polycab Cables


A . CA BLE INS PECT ION
Inspect every cable reel for damage before
accepting the shipment.Be particularly
alert for cable damage if:
1. A reel is lying flat on its side
2. Several reels are stacked
3. Other freight is stacked on a reel
4. Nails have been driven into reel flanges
to secure shipping blocks
5. A reel flange is damaged
6. A cable covering is removed, stained or
damaged
7. A cable end seal is removed or
damaged. A reel has been dropped
(hidden damage likely)

Dos

B. CAB LE HANDLING &


STORAGE
Damage to cables can occur due to the
incorrect handling to which the drums
and cables may be subjected; causing
breakdown of the drum flanges and in
exceptional cases, movement of the drum
barrel takes place. Once this breakdown of
the drum occurs, the cable is immediately
exposed to damage. Cables damaged during
handling & storage can cause service
failures when the subject cable is put to
use.
Thus the following is a list of Dos and
Donts that should be followed while
handling and storing the cables before it
is put to use.

Donts

When off loading reels from a truck, lower


reels carefully using a hydraulic gate, hoist
or forklift truck

Never drop reels. If reels must be rolled, roll in


opposite direction of the cable wraps to keep
cable from loosening on the reel.

If a fork lift is used, approach the reel from


the flange side. Position the forks such that
the reel is lifted by both reel flanges. Also
Consideration should be given to, Traffic
patterns during off-loading & damage during the time in storage

Do not allow the lift forks to contact the cable.


Care must be taken by the fork lift operator not
to make sudden turns or stops.

Cable reels should be stored on hard surfaces resting on the flanges edge (flanges
vertical). Align reels flange to flange and,
if possible, arrange so that first in is first
out.

Multiple reels stacked on top of each other


(Pancake storage) is not recommended for
cable drums. The weight of the stack can total
thousands of kgs. creating an enormous load on
the bottom reel. Also, damage to the reel and/
or cable will likely occur when the reel is flipped
for transit. A concentration of stress on the reel
flange may cause it to break and subsequently
damage the cable.

When using a hoist, install a mandrel


through the reel arbor holes and attach a
sling. Use a spreader bar approximately 6
inches longer than the overall reel width
placed between the sling ends just above
the reel flanges.

This may lead to the bending of the reel flanges


and mashing the cable

23

Handling, Storage and Laying of Polycab Cables


C. PR E - INS TALLAT ION
To ensure safety during cable installation,
following shall be checked prior to
installation.
1. The cable selected is proper for
designed application.
2. The cable has not been damaged in
transit or storage.
Review all applicable state and national
codes to verify that the cable chosen
is appropriate for the job. Also consult
your local electricity authority. Next, you
must identify any existing cable damage
and prevent any further damaged from
occurring. This is done through proper
cable inspection, handling and storage.

D. INSTALLATION & LAYING


Mechanical stresses during installation
are generally more severe than those
encountered while in service. Thus care
should be taken as regards to the following
while installation and laying of cables.
1. Polycab recommend the laying and
installation of cables as per IS:
1255/84.
2. Care shall be taken during laying to
avoid sharp bending, and twisting.
3. Cable shall be un wound from the drum
by lifting the drum on the center
4. Shaft supported both ends with
suitablejacks / stands.

5. Under no circumstances the cable


winding shall be lifted off a coil or drum
lying flat at the flanges. This would
cause serious twist and damages.
6. Suitable protection shall be provided
to the cables against mechanical
damages, it includes covers, pipes etc.

E. RECOMMENDED MINIMUM
BENDING RADIUS FOR HEAVY
DUTY CABLES.

Single Core : 20 x D

Multicore : 15 x D

Where D = Diameter of cable in mm

F. RECOM M ENDED SAF E


PULLING FORCE WIT H
STOCK INGS:
a) For Unarmoured Cable : P = 5 D2
b) For Armoured Cable

: P = 9 D2

Where P = Pulling Force


Where D = Diameter of cable in mm

G. RECOMMENDED SAFE PULLING


FORCE WHEN PULLED WITH
PULLING EYE :
a) For Aluminium Conductor : 30 N/mm2
b) For Copper Conductor : 50 N/mm2

DO NOT ATTEMPT COILING OF CABLE ON THE GROUND

ON THE GROUND CABLE CAN BE FLAKED IN A FIGURE OF EIGHT FORMATION

Note: R Minimum Permissible bending radius of cable.

24

Production Facilities at Daman Factory


POLYCAB REGIONAL OFFICES
CHENNAI : Old No. 5/2, New No.9/2 Gopalkrishna Road, T-Nagar, CHENNAI - 600 017.
Tel: 044 42022775 / 32969257 Fax: 044 42022774 Email : chennai@polycab.com
BARODA : 9, Khushbu Corner, 56, Vishwas Colony, Alkapuri, BARODA - 390 007.
Tel: 0265 3252825 Fax: 0265 3083366 Email : gujarat@polycab.com
PUNE : 36, Sangam Project, Off. Indian Air Lines, Near RTO (PUNE), Ambedkar Road,
PUNE - 411 001. Tel: 020 26058277 / 30209678 Email : pune@polycab.com
BENGALURU : #104/6, 5th Cross, 5th Block, SSI Area, Rajajinagar, BENGALURU - 560 010.
Tel: 080 23102172 Fax: 080 23102071 Email : karnataka@polycab.com

SECUNDERABAD : 401, A, 4th floor, Suryakiran Complex, S. D. Road,


SECUNDERABAD - 500 003.
Tel: 040 66326228 / 30962600 Fax: 040 66326229 / 3072355
Email : andhra@polycab.com
DELHI : O-13, 3rd Floor, Lajpat Nagar II, NEW DELHI - 110 024.
Tel: 011 29841721-24 Fax: 011 29841697 Email : north@polycab.com
KOLKATA : 1-3, A, South End Park, KOLKATA - 700 029.
Tel: 033 32929602-3 Fax: 033 24197706 Email : pwplkolkatta@polycab.com

Wiring the World

Polyc ab Wires PVt. Ltd.


(an ISO 9001:2008, 14001:2004, 18001:2007 Company)
Regd. & Head office :

Tel.
Fax

: 91-22-2432 7070 - 4, 6735 1400


: 91-22-2432 7075

E-mail : enquiry@polycab.com
Website : www.polycab.com

Dec 2012

Polycab House, 771, Pandit Satwalekar Marg,


Mahim (W), Mumbai 400 016.