Epoxy-Tie Adhesive
Epoxy-Tie ET is a two-component, 100% solids epoxy-based system for use as a high strength, non-shrink anchor grouting material. Resin and hardener are dispensed and mixed simultaneously through the mixing nozzle. ET meets the ASTM C-881 specifications for Type I II, IV and V Grade 3, Classes B and C. USES: Threaded rod anchoring Rebar dowelling Bonding hardened concrete to hardened concrete Pick proof sealant around doors, windows and fixtures Paste-over for crack injection. CODES: ICC/ICBO ER-4945; City of L.A. RR25185, RR25120; Metro Dade 01-1026.2; Multiple DOT Listings. The Load Tables list values based upon results from the most recent testing and may not reflect those in current code reports. Where code jurisdictions apply, consult the current reports for applicable load values. APPLICATION: Surfaces to receive epoxy must be clean. For installations in or through standing water, see page 11 for details. The base material temperature must be 40 F or above at the time of installation. For best results, material should be 70 F - 80 F at the time of application. Cartridges should not be immersed in water to facilitate warming. To warm cold material, the cartridges should be stored in a warm, uniformly heated area or storage container for a sufficient time to allow epoxy to warm completely. Mixed material in nozzle can harden in 5-7 minutes at a temperature of 40 F or above. SHELF LIFE: Two years from date of manufacture in unopened container. STORAGE CONDITIONS: For best results store between 45 F - 90 F. To store partially used cartridges, leave hardened nozzle in place. To re-use, attach new nozzle. COLOR: Resin white; Hardener black; amine based. When properly mixed, ET adhesive will be a uniform medium gray color. CLEAN UP: Uncured material Wipe up with cotton cloths. If desired scrub area with abrasive, waterbased cleaner and flush with water. If approved, solvents such as ketones (MEK, acetone, etc.), laquer thinner, or adhesive remover can be used. DO NOT USE SOLVENTS TO CLEAN ADHESIVE FROM SKIN. Take appropriate precautions when handling flammable solvents. Solvents may damage surfaces to which they are applied. Cured Material: Chip or grind off surface. TEST CRITERIA: Anchors installed with ET adhesive have been tested in accordance with ICBO's Acceptance Criteria for Adhesive Anchors in Concrete and Masonry Elements (AC58). Between Simpson Strong-Tie in-house testing and ICBO report ER-4945, ET adhesive is recognized for the following: Seismic and Wind Loading. Long Term Creep at Elevated Temperature. Static Loading at Elevated Temperature. Damp Holes. Freeze-Thaw Conditions. Critical and Minimum Edge Distance and Spacing. In addition, anchors installed with ET adhesive have been tested in accordance with ICBO's Acceptance Criteria for Unreinforced Masonry Anchors (AC60). PROPERTY Consistency (77 F) Heat Deflection Bond Strength Water Absorption 1. Compressive Yield Strength Compressive Modulus Gel Time (77 F) TEST METHOD ASTM C 881 ASTM D 648 ASTM C 882 ASTM D 570 ASTM D 695 ASTM D 695 ASTM C 881 RESULTS Non-Sag/Thixotropic Paste 168F (76 C) 2,030 psi (2 days) 4,240 psi (14 days) 0.19% (24 hours) 9,174 psi (24 hours) 13,390 psi (7 days) 658,200 psi (7 days) 10 min 60 gram mass 30 min Thin film EDT22A EMN22 ET22

ET Epoxy-Tie

Catalog C-SAS-2004 Copyright 2003 SIMPSON STRONG-TIE COMPANY INC.

ET56

ET Cartridge Systems
Model No. ET22 ET56 Capacity Cartridge Carton ounces Type Quantity (cubic inches) 22 side-by-side 10 (39.7) 56 side-by-side 6 (101.1) Dispensing Tool(s) EDT22A or EDT22AP EDT56AP Mixing Nozzle EMN22 EMN50

1. Bulk containers also available, call Simpson for details. 2. Cartridge Estimation Guides are available on pages 65-67. 3. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available on pages 68-72.

CHEMICAL RESISTANCE Very good to excellent against distilled water, inorganic acids and alkalis. Fair to good against organic acids and alkalis, and many organic solvents. Poor against Ketones. For more detailed information visit our website or contact Simpson and request Technical Bulletin T-SAS-CHEMRES03.

SUGGESTED SPECIFICATIONS: Anchoring Adhesive shall be a twocomponent 100% solids epoxy based system supplied in manufacturer's standard side-by-side cartridge and dispensed through a static-mixing nozzle supplied by the manufacturer. Epoxy shall meet the minimum requirements of ASTM C-881 specification for Type I, II, IV, and V, Grade 3, Class B and C and must develop a minimum 13,390 psi compressive yield strength after 7 day cure. Epoxy must have a heat deflection temperature of a minimum 168F(76C). Adhesive shall be Epoxy-Tie ET from Simpson Strong-Tie, Dublin, CA. Anchors shall be installed per Simpson Strong-Tie's instructions for Epoxy-Tie ET.

49

ET
Epoxy-Tie Adhesive
Tension Loads for Threaded Rod Anchors in Normal-Weight Concrete
Rod Dia. in. (mm) 3/8 (9.5) 1/2 (12.7) 5/8 (15.9) 3/4 (19.1) 7/8 (22.2) 1 (25.4) 1 1/4 (31.8) Drill Bit Dia. in. Embed. Depth in. (mm) 3 1/2 (89) 4 1/4 (108) 5 (127) 6 3/4 (171) 7 3/4 (197) 9 (229) 11 1/4 (286) Critical Edge Dist. in. (mm) 5 1/4 (133) 6 3/8 (162) 7 1/2 (191) 10 1/8 (257) 11 5/8 (295) 13 1/2 (343) 16 7/8 (429) Critical Spacing Dist. in. (mm) 14 (356) 17 (432) 20 (508) 27 (686) 31 (787) 36 (914) 45 (1143) Tension Load Based on Bond Strength f'c >= 2000 psi (13.8 MPa) Concrete Ultimate lbs. (kN) 8,777 (39.0) 15,368 (68.4) 22,877 (101.8) 35,459 (157.7) 43,596 (193.9) 47,333 (210.5) 78,748 (350.3) Std. Dev. lbs. (kN) 324 (1.4) 605 (2.7) 718 (3.2) 4,940 (22.0) 1,130 (5.0) 1,243 (5.5) 4,738 (21.1) Allowable lbs. (kN) 2,195 (9.8) 3,840 (17.1) 5,720 (25.4) 8,865 (39.4) 10,900 (48.5) 11,835 (52.6) 19,685 (87.6) Tension Load Based on Steel Strength A307 (SAE 1018) Allowable lbs. (kN) 2,105 (9.4) 3,750 (16.7) 5,875 (26.1) 8,460 (37.6) 11,500 (51.2) 15,025 (66.8) 23,490 (104.5)

*
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable A193 GR B7 F593 bond are based on a safety factor of 4.0. (SAE 4140) (A304SS) 3. Allowable loads may be increased by 33 percent for short-term loading due Allowable Allowable to wind or seismic forces. lbs. (kN) lbs. (kN) 4. Refer to allowable load adjustment 4,535 3,630 factors for spacing and edge distance (20.2) (16.1) on pages 55 & 56. 5. Refer to In-Service Temperature 8,080 6,470 Sensitivity chart for allowable load (35.9) (28.8) adjustment for temperature. 12,660 10,130 6. Anchors are permitted to be used within (56.3) (45.1) fire-resistive construction, provided the 18,230 12,400 anchors resist wind or seismic loads only. For use in fire-resistive construction, the (81.1) (55.2) anchors can also be permitted to be used 24,785 16,860 to resist gravity loads, provided special (110.2) (75.0) consideration has been given to fire 32,380 22,020 exposure conditions. (144.0) (97.9) 7. Anchors are not permitted to resist tension forces in overhead or wall 50,620 34,420 installations unless proper consideration (225.2) (153.1) is given to fire-exposure and elevated * temperature conditions.

1/2 5/8 3/4 7/8 1 1 1/8 1 3/8

Shear Loads for Threaded Rod Anchors in Normal-Weight Concrete


Rod Dia. in. (mm) 3/8 (9.5) 1/2 (12.7) 5/8 (15.9) 3/4 (19.1) 7/8 (22.2) 1 (25.4) 1 1/4 (31.8) Drill Bit Dia. in. Embed. Depth in. (mm) 3 1/2 (89) 4 1/4 (108) 5 (127) 6 3/4 (171) 7 3/4 (197) 9 (229) 11 1/4 (286) Critical Edge Dist. in. (mm) 5 1/4 (133) 6 3/8 (162) 7 1/2 (191) 10 1/8 (257) 11 5/8 (295) 13 1/2 (343) 16 7/8 (429) Critical Spacing Dist. in. (mm) 5 1/4 (133) 6 3/8 (162) 7 1/2 (191) 10 1/8 (257) 11 5/8 (295) 13 1/2 (343) 16 7/8 (429) Shear Load Based on Concrete Edge Distance f'c >= 2000 psi (13.8 MPa) Concrete Ultimate lbs. (kN) 7,615 (33.9) 11,273 (50.1) 19,559 (87.0) 27,696 (123.2) 53,960 (240.0) 64,572 (287.2) Std. Dev. lbs. (kN) 591 (2.6) 1,502 (6.7) 1,289 (5.7) 2,263 (10.1) 3,821 (17.0) 3,503 (15.6) Allowable lbs. (kN) 1,905 (8.5) 2,820 (12.5) 4,890 (21.8) 6,925 (30.8) 6,925 (30.8) 13,490 (60.0) 16,145 (71.8)

Shear Load Based on Steel Strength A307 (SAE 1018) Allowable lbs. (kN) 1,085 (4.8) 1,930 (8.6) 3,025 (13.5) 4,360 (19.4) 5,925 (26.4) 7,740 (34.4) 12,100 (53.8) A193 GR B7 (SAE 4140) Allowable lbs. (kN) 2,340 (10.4) 4,160 (18.5) 6,520 (29.0) 9,390 (41.8) 12,770 (56.8) 16,680 (74.2) 26,075 (116.0) F593 (A304SS) Allowable lbs. (kN) 1,870 (8.3) 3,330 (14.8) 5,220 (23.2) 6,385 (28.4) 8,685 (38.6) 11,345 (50.5) 17,730 (78.9)

1/2 5/8 3/4 7/8 1 1 1/8 1 3/8

Catalog C-SAS-2004 Copyright 2003 SIMPSON STRONG-TIE COMPANY INC.

1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Allowable loads may be increased by 33 percent for short-term loading due to wind or seismic forces. 4. Refer to allowable load adjustment factors for spacing and edge distance on pages 55 & 56. 5. Refer to In-Service Temperature Sensitivity chart for allowable load adjustment for temperature. 6. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire exposure conditions.

ET Epoxy-Tie

*
Tension Loads for Threaded Rod Anchors in Normal-Weight Concrete Stemwall
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Stemwall Depth Width in. in. (mm) (mm) 9 1/2 (241.3) 12 (304.8) 12 1/2 (317.5) 15 1/2 (393.7) 6 (152.4) 6 (152.4) 8 (203.2) 8 (203.2) Min. Edge Dist. in. (mm) 1 3/4 (44.5) 1 3/4 (44.5) 1 3/4 (44.5) 1 3/4 (44.5) Min. End Dist. in. (mm) 5 (127.0) 5 (127.0) 5 (127.0) 5 (127.0) Tension Load Based on Bond Strength f'c >= 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 10,720 (47.7) 16,150 (71.8) 17,000 (75.6) 23,340 (103.8) 1,559 (6.9) 260 (1.2) 303 (1.3) 762 (3.4) 2,680 (11.9) 4,040 (18.0) 4,250 (18.9) 5,835 (26.0) Tension Load Based on Steel Strength A307 (SAE 1018) Allowable lbs. (kN) 5,875 (26.1) 5,875 (26.1) 11,500 (51.2) 11,500 (51.2)

*See page 5 for an


explanation of the load table icons
d

Edge

6"or 8"

W=

En

5/8 (15.9) 5/8 (15.9) 7/8 (22.2) 7/8 (22.2)

3/4 3/4 1 1

1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0.

3. Allowable loads may be increased by 33 percent for short-term loading due to wind or seismic forces. 4. Refer to In-Service Temperature Sensitivity chart for allowable load adjustment for temperature.

5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire exposure conditions.

Edge and end distances for threaded rod in concrete foundation stemwall corner installation 51

EPOXY-TIE
Estimating Guides
Estimating Guide for 22 oz. Cartridge using Threaded Rod Installations per Cartridge
Rod Dia. (in.) 3/8 3/8 1/2 1/2 5/8 5/8 3/4 3/4 7/8 7/8 1 1 1 1/8 1 1/8 1 1/4 1 1/4 Drill Bit Dia. (in.) 7/16 1/2 9/16 5/8 3/4 7/8 7/8 1 1 1 1/8 1 1/8 1 1/4 1 1/4 1 3/8 1 3/8 1 1/2 THREADED ROD IN SOLID BASE MATERIAL HOLE DEPTH (inches) 8 9 10 11 12 13 14 43 39 35 32 29 27 25 27 24 22 20 18 17 16 32 28 25 23 21 19 18 20 18 16 14 13 12 11 16 14 12 11 10 10 9 9 8 7 6 6 5 5 13 11 10 9 8 8 7 8 7 6 5 5 5 4 11 9 8 8 7 6 6 6 6 5 5 4 4 4 9 8 7 6 6 5 5 5 5 4 4 4 3 3 7 7 6 5 5 5 4 5 4 4 3 3 3 3 7 6 5 5 4 4 4 4 4 3 3 3 3 2

2 174 110 126 80 62 36 50 30 42 25 35 22 30 19 27 17

3 116 73 84 53 42 24 33 20 28 17 23 15 20 13 18 12

4 87 55 63 40 31 18 25 15 21 13 17 11 15 10 13 9

5 70 44 51 32 25 14 20 12 17 10 14 9 12 8 11 7

6 58 37 42 27 21 12 17 10 14 8 12 7 10 6 9 6

7 50 31 36 23 18 10 14 9 12 7 10 6 9 5 8 5

15 23 15 17 11 8 5 7 4 6 3 5 3 4 3 4 2

16 22 14 16 10 8 4 6 4 5 3 4 3 4 2 3 2

17 20 13 15 9 7 4 6 4 5 3 4 3 4 2 3 2

18 19 12 14 9 7 4 6 3 5 3 4 2 3 2 3 2

19 18 12 13 8 7 4 5 3 4 3 4 2 3 2 3 2

20 17 11 13 8 6 4 5 3 4 3 3 2 3 2 3 2

Estimating Guide for 22 oz. Cartridge using Rebar Installations per Cartridge
Rebar Size (no.) 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 Drill Bit Dia. (in.) 7/16 1/2 9/16 5/8 3/4 7/8 7/8 1 1 1 1/8 1 1/8 1 1/4 1 1/4 1 3/8 1 1/2 1 3/4 1 5/8 1 7/8 REBAR IN SOLID BASE MATERIAL HOLE DEPTH (inches) 9 10 11 12 13 52 47 42 39 36 29 26 24 22 20 43 38 35 32 30 23 20 18 17 16 18 16 15 14 13 9 8 7 7 6 15 13 12 11 10 8 7 6 6 5 13 11 10 10 9 7 6 5 5 5 11 10 9 8 8 6 5 5 4 4 10 9 8 7 7 5 5 4 4 4 5 5 4 4 4 3 2 2 2 2 5 4 4 4 3 2 2 2 2 2

Epoxy-Tie Estimation Guides

Estimating Guide for 22 oz. Cartridge and Screen Tubes Installations per Cartridge
Rod Dia. (in.) 3/8 1/2 5/8 3/4 Drill Bit Dia. (in.) 9/16 11/16 7/8 1 THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 9 10 11 12 13 14 15 19 17 12 11 7 6 6 5 5 5 5 4 4 4 3 3

3 1/2 49 31 18 13

4 43 27 15 11

5 34 22 12 9

6 29 18 10 8

7 25 16 9 7

8 21 14 8 6

16

17

18

19

20

21

Tables are estimations. Actual usage may vary depending on waste.

66

Catalog C-SAS-2004 Copyright 2003 SIMPSON STRONG-TIE COMPANY INC.

2 233 131 192 102 82 41 65 35 57 30 49 27 44 24 23 12 22 11

3 155 87 128 68 55 27 44 23 38 20 33 18 29 16 16 8 15 7

4 116 65 96 51 41 21 33 17 29 15 25 13 22 12 12 6 11 6

5 93 52 77 41 33 16 26 14 23 12 20 11 18 10 9 5 9 4

6 78 44 64 34 27 14 22 12 19 10 16 9 15 8 8 4 7 4

7 67 37 55 29 23 12 19 10 16 9 14 8 13 7 7 3 6 3

8 58 33 48 25 20 10 16 9 14 7 12 7 11 6 6 3 6 3

14 33 19 27 15 12 6 9 5 8 4 7 4 6 3 3 2 3 2

15 31 17 26 14 11 5 9 5 8 4 7 4 6 3 3 2 3 1

16 29 16 24 13 10 5 8 4 7 4 6 3 6 3 3 1 3 1

17 27 15 23 12 10 5 8 4 7 4 6 3 5 3 3 1 3 1

18 26 15 21 11 9 5 7 4 6 3 5 3 5 3 3 1 2 1

19 25 14 20 11 9 4 7 4 6 3 5 3 5 3 2 1 2 1

20 23 13 19 10 8 4 7 3 6 3 5 3 4 2 2 1 2 1