GSM
68P02902W06-C006
GSM
Restrictions
The software described in this document is the property of Motorola. It is furnished under a license agreement and may be used and/or disclosed only in accordance with the terms of the agreement. Software and documentation are copyright materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Motorola.
Accuracy
While reasonable efforts have been made to assure the accuracy of this document, Motorola assumes no liability resulting from any inaccuracies or omissions in this document, or from the use of the information obtained herein. Motorola reserves the right to make changes to any products described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Motorola does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey license under its patent rights of others.
Trademarks
and MOTOROLA are registered trademarks of Motorola Inc. Intelligence Everywhere, M-Cell and Taskfinder are trademarks of Motorola Inc. All other brands and corporate names are trademarks of their respective owners.
. . .
ii
29 Jan 2007
GSM
Contents
Issue status of this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reporting safety issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warnings and cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Devices sensitive to static . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motorola manual sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GMR amendment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GMR amendment record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 5 6 7 11 12 13 14 15
Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech.
111 1 3 1 4 1 5 1 6 1 6 1 7 1 8 1 9 1 9 110 111 111 111 111 112 113 114 114 114 114 115 115 116 118 118
68P02902W06-C006
iii
GSM
iv
29 Jan 2007
GSM
Fan unit description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature control overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cabinet over temperature control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cabinet restart after shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan unit overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan operation and reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter option and effect on fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34 3 3 3 3 33 33 34 34 34
53 5 6 511 516 53 5 3 5 4 5 5 5 5
68P02902W06-C006
GSM
Frequency hopping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF main component explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Description of RF test modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SURF module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of CTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU internal boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of a CTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU front panel detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU Tx connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU Rx function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU interface function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tx blocks overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Restrictions when using CTU2s in Horizonmacro indoor . . . . . . . . . . . . . Overview of the CTU2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU2 internal boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of a CTU2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU2 front panel detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU2 Tx connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU2 Rx function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU2 interface function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EGPRS capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blanking plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of transceiver frequency hopping . . . . . . . . . . . . . . . . . . . . . . . . . Synthesizer frequency hopping (SFH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Baseband frequency hopping (BBH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Feedthrough plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SURF module overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single band SURF module view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional description of the single band SURF . . . . . . . . . . . . . . . . . . . . . Single band SURF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual band SURF module view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional description of dual band SURF modules . . . . . . . . . . . . . . . . . Dual band SURF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HCU plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to transmit blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw retention in Tx block locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of basket for Tx blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit block connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of Tx block connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech.
524 56 5 6 58 59 510 525 511 511 512 513 514 515 515 515 533 516 516 517 518 519 520 521 521 522 523 536 524 524 524 537 525 526 528 529 530 531 532 538 533 533 534 534 535
TDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 540 Purpose of blanking plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 536 View of blanking plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 536
Service Manual: Horizonmacro indoor 68P02902W06-C006
vi
29 Jan 2007
GSM
Dual band TDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Purpose of feedthrough plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of feedthrough plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Feedthrough plate connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HCU overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HCU view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HCU functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HCU connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of TDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TDF view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TDF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TDF connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of dual band TDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual band TDF view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual band TDF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dual band TDF connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCF overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCF view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DCF connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of DDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DDF view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DDF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DDF connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB control board (TCB) and set switch . . . . . . . . . . . . . . . . . . . . . . . . . . . TCB and link redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB functional description and diagram . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech.
542 537 537 537 544 538 538 538 539 546 540 540 541 541 548 542 542 543 543 544 544 545 545 546 546 547 547 548 548 548 549 550 551
621 6 3 6 3 6 4 6 4 6 5 6 5
68P02902W06-C006
vii
GSM
FMUX module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MCUF overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Capability to replace MCU of M-Cell6 and M-Cell2 . . . . . . . . . . . . . . . . . . GPROC TSW and GLCK functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MCUF module view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MCUF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Link to redundant MCUF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front panel interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front panel switches and indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PIX interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DRAM, flash EPROM and code loading functions . . . . . . . . . . . . . . . . . . . ASIC functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sync block functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integral MCUF FMUX functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of NIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIU locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIU command identity number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module view and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIU functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIU diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIU/MCUF framing and clocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Distance measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Radio signalling links (RSLs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T1 NIU need to set link type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of T43/BIB-NIU connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIU to T43 mapping and command ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diagram of T43 connection to NIUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of FMUX module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FMUX module view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FMUX functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FMUX functional explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm module overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm module view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm module functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm module replacement effect on alarms . . . . . . . . . . . . . . . . . . . . . . Alarm collection from extension cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . Alarm module display presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech. Tech.
623 66 6 6 67 67 68 69 6 9 610 610 611 612 613 615 625 616 616 616 617 617 618 619 619 619 620 620 621 621 622 623 623 624 624 625 625 626 626 626 627
viii
29 Jan 2007
GSM
6-monthly maintenance procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reporting faulty devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Routine maintenance intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-monthly maintenance procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of tool list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tool list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning agents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Annual check of the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assumptions door, hood, and stacking bracket . . . . . . . . . . . . . . . . . . . . Door operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hood removal and refitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stacking bracket removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stacking bracket front cover removal and fit . . . . . . . . . . . . . . . . . . . . . . . . 24-monthly maintenance procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type of procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning inlets and exhaust grilles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing the air filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary of 12-monthly procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Checking and cleaning fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cabinet modules in operational positions . . . . . . . . . . . . . . . . . . . . . . . . . . Checking normal operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Powering down the cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Earth continuity check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC power system insulation check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power up procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary of 24-monthly procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical inspection of cabinet, locks and hinges . . . . . . . . . . . . . . . . .
Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint.
110 1 3 1 3 13 1 4 111 1 5 1 5 1 7 114 18 1 8 1 8 18 1 9 119 110 110 110 111 111 112 113 114 114 115 115 116 119 120
Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint.
2 9 2 3 23 24 2 5 210 26 2 6 2 6 2 6
68P02902W06-C006
ix
GSM
Replacing a stacking bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to door replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Views of door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacement of door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
211 2 7 2 7 28
Replacing a fan module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 213 Overview of heat sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 29 Procedure for heat sensor replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 29 Replacing a circuit breaker module (CBM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to hood replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing the hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. Maint. Maint. Maint. 215 210 210 210
Replacing a power supply module (PSM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 217 View of stacking bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 211 Procedure to replace a stacking bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 212 Replacing a hold-up battery module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to fan replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of fan modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Identifying fan module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing fan modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preconditions for CBM replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Views of CBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a CBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preserving transceiver calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to PSM replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preconditions for PSM replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of PSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a non-redundant PSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a redundant PSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. 219 213 213 214 214 221 215 215 216 225 217 217 217 218 218
Enabling the preserve transceiver calibration data feature . . . . . . . . . . . . . . . . . Maint. 230 To Replace a hold-up battery module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 219 Transceiver calibration data exchange procedures . . . . . . . . . . . . . . . . . . . . . . . Preconditions for transceiver replacement . . . . . . . . . . . . . . . . . . . . . . . . . . View of a CTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of a CTU2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacement procedure for a transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . Calibrating transceiver bay level offset tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to preserving transceiver calibration . . . . . . . . . . . . . . . . . . . . Calibration data overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commands used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CINDY commissioning tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a SURF module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to the preserve transceiver calibration data feature . . . . . . . Enabling the preserve feature at the OMC-R . . . . . . . . . . . . . . . . . . . . . . . Enabling the preserve feature at the BSC . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Manual: Horizonmacro indoor 68P02902W06-C006
Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint.
231 221 221 222 223 236 225 225 229 229 229 262 230 230 230
29 Jan 2007
GSM
Replacing a Tx block, HCU or plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to transceiver calibration data exchange procedures . . . . . Preserve transceiver calibration data procedure . . . . . . . . . . . . . . . . . . . . Transceiver calibration procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transceiver recalibration procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a CCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to bay level offset tables calibration . . . . . . . . . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU Rx bay level calibration procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU2 Rx bay level calibration procedures . . . . . . . . . . . . . . . . . . . . . . . . . . Site restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital module replacement (MCUF, NIU, FMUX, BPSM, Alarm) . . . . . . . . . . . . Preconditions for SURF replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of the SURF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a SURF module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Redundant MCUF firmware compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to Tx block replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Views of typical Tx block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing a Tx block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blanking plate, feedthrough plate or HCU replacement . . . . . . . . . . . . . . Calibrating the MCUF (GCLK) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of CCB replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of CCBs in stacking bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Removing CCBs and CCB control boards . . . . . . . . . . . . . . . . . . . . . . . . . . Fitting replacement CCBs and CCB control boards . . . . . . . . . . . . . . . . . Introduction to digital module replacement . . . . . . . . . . . . . . . . . . . . . . . . . Diagram of digital modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing digital modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview of MCUF firmware compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . Checking MCUF firmware compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . Updating redundant MCUF firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Testing MCUF redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to MCUF (GLCK) calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . When to calibrate the GCLK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparation for GCLK calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GCLK calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint.
265 231 231 232 234 269 236 236 237 252 261 272 262 262 263 275 265 266 267 268 279 269 269 270 271 272 272 273 275 275 275 278 279 279 279 280 281
68P02902W06-C006
xi
GSM
Normal CTU2 cell site power calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to test equipment, leads and plugs . . . . . . . . . . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test leads required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CTU VSWR and cell site power calibration for CCBs . . . . . . . . . . . . . . . . . . . . . . Introduction to output power calibration and VSWR check . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commands used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test stages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparation for output power calibration and VSWR check . . . . . . . . . . . Output format for clear_cal_data command . . . . . . . . . . . . . . . . . . . . . . . . Checking the database equipage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to normal VSWR and cell site power calibration . . . . . . . . . . Automatic VSWR test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual VSWR test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VSWR reverse power test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tx output power calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Checking the E1/T1 link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tx output power calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tx cabinet channel numbers and frequencies . . . . . . . . . . . . . . . . . . . . . . Checking PIX connections and alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to CCB VSWR and cell site power calibration . . . . . . . . . . . . Calibration procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB cavities tuning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VSWR calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cell site power calibration procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parking the CCB cavities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Repeat for remaining cavities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Site restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF output power check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Returning the CTUs to call processing mode . . . . . . . . . . . . . . . . . . . . . . . Introduction to checking the database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commands used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparation for database checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Database equipage check procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to checking the E1/T1 link . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commands used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparation for the E1/T1 link check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E1/T1 link test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to checking the PIX connections and alarms . . . . . . . . . . . . Test equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commands used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparing for the PIX connections and alarms test . . . . . . . . . . . . . . . . . . PIX connection test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint.
321 3 4 3 4 35 326 3 7 3 8 39 310 311 314 334 315 316 317 318 319 337 321 325 339 326 327 328 329 330 330 331 332 332 333 334 334 334 334 335 337 337 337 337 338 339 339 339 340 340
xii
29 Jan 2007
GSM
Glossary of unique terms for this equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction to Horizonmacro indoor parts list . . . . . . . . . . . . . . . . . . . . . . . FRU items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ordering method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diagram of cabinet modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spares tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of CCBs in stacking bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCB spares table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital module and BPSM locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital module and BPSM table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diagram of the door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Door table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diagram of hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indoor hood table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint. Maint.
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I1
68P02902W06-C006
xiii
GSM
List of Figures
Figure Tech. 1-1 Indoor cabinet on plinth with optional hood . . . . . . . . . . . . . . . Tech. 13 Figure Tech. 1-2 Cabinet with components identified (door and base plinth removed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 15 Figure Tech. 1-3 View of two cabinets stacked in maximum assembly . . . . . . . Tech. 17 Figure Tech. 1-4 Functional diagram of cabinet components . . . . . . . . . . . . . . . Tech. 18 Figure Tech. 1-5 Digital connections in maximum BTS site . . . . . . . . . . . . . . . . Tech. 19 Figure Tech. 1-6 Indoor cabinet site layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 118 Figure Tech. 2-1 Closed cabinet and cabinet with hood removed and door open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 23 Figure Tech. 2-2 Cabinet, without door or hood, showing main components . Tech. 25 Figure Tech. 2-3 SURF harness installed in empty cabinet. . . . . . . . . . . . . . . . . Tech. 26 Figure Tech. 2-4 SURF harness with connectors indicated . . . . . . . . . . . . . . . . Tech. 27 Figure Tech. 2-5 Top panel with major features labelled . . . . . . . . . . . . . . . . . . . Tech. 28 Figure Tech. 2-6 View of CBIA cage and the interface panel . . . . . . . . . . . . . . . Tech. 29 Figure Tech. 2-7 Rear view of CBIA showing backplane and harness . . . . . . . Tech. 210 Figure Tech. 2-8 Front view of CBIA cage showing where modules fit . . . . . . . Tech. 211 Figure Tech. 2-9 Interface panel connector locations . . . . . . . . . . . . . . . . . . . . . Tech. 213 Figure Tech. 2-10 Balanced-line interconnect board (BIB) . . . . . . . . . . . . . . . . . Tech. 215 Figure Tech. 2-11 Type 43 interconnect board (T43) . . . . . . . . . . . . . . . . . . . . . . Tech. 217 Figure Tech. 2-12 External and internal view of cabinet door . . . . . . . . . . . . . . . Tech. 220 Figure Tech. 2-13 View of hood as seen from the front of the cabinet . . . . . . . Tech. 221 Figure Tech. 2-14 View of stacking bracket with CCB basket installed. . . . . . . Tech. 222 Figure Tech. 2-15 View of two stacked Horizonmacro indoor cabinets showing stacking bracket front covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 223 Figure Tech. 3-1 View of 2-fan and 4-fan units . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 34 Figure Tech. 4-1 Location of power modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 43 Figure Tech. 4-2 View of PSM with LEDs identified . . . . . . . . . . . . . . . . . . . . . . . Tech. 45 Figure Tech. 4-3 View of the hold-up battery module . . . . . . . . . . . . . . . . . . . . . . Tech. 47 Figure Tech. 4-4 Hold-up battery module electrical layout . . . . . . . . . . . . . . . . . Tech. 410 Figure Tech. 4-5 Views of CBM with circuit breaker buttons identified . . . . . . . Tech. 412 Figure Tech. 4-6 BPSM view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 414 Figure Tech. 4-7 Functional diagram of BPSM . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 415 Figure Tech. 5-1 RF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 59 Figure Tech. 5-2 View of CTU showing main external features . . . . . . . . . . . . . Tech. 513 Figure Tech. 5-3 CTU front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 514 Figure Tech. 5-4 CTU2, showing main external features . . . . . . . . . . . . . . . . . . . Tech. 519 Figure Tech. 5-5 CTU2 front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 520
Service Manual: Horizonmacro indoor 68P02902W06-C006
xiv
29 Jan 2007
GSM
Figure Tech. 5-6 SURF to CTU2 interconnections . . . . . . . . . . . . . . . . . . . . . . . . Tech. 521 Figure Tech. 5-7 Single band SURF module (later type) with features identified . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 526 Figure Tech. 5-8 Single band SURF module (earlier type) with features identified . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 527 Figure Tech. 5-9 Functional diagram of the single band SURF module . . . . . . Tech. 529 Figure Tech. 5-10 Later type dual band SURF module with features identified Tech. 530 Figure Tech. 5-11 Functional diagram of the dual band SURF module . . . . . . Tech. 532 Figure Tech. 5-12 View of top panel showing Tx block basket . . . . . . . . . . . . . . Tech. 534 Figure Tech. 5-13 Typical Tx block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 535 Figure Tech. 5-14 View of blanking plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 536 Figure Tech. 5-15 View of feedthrough plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 537 Figure Tech. 5-16 HCU plate view showing connectors . . . . . . . . . . . . . . . . . . . Tech. 538 Figure Tech. 5-17 HCU functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 538 Figure Tech. 5-18 View of TDF Tx block with connectors identified . . . . . . . . . Tech. 540 Figure Tech. 5-19 TDF functional diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 541 Figure Tech. 5-20 View of dual band TDF Tx block with connectors identified Tech. 542 Figure Tech. 5-21 Dual band TDF functional diagram . . . . . . . . . . . . . . . . . . . . . Tech. 543 Figure Tech. 5-22 DCF Tx block view with connectors identified . . . . . . . . . . . . Tech. 544 Figure Tech. 5-23 Functional diagram of the DCF . . . . . . . . . . . . . . . . . . . . . . . . Tech. 545 Figure Tech. 5-24 DDF Tx block view with connectors identified . . . . . . . . . . . . Tech. 546 Figure Tech. 5-25 Functional diagram of the DDF . . . . . . . . . . . . . . . . . . . . . . . . Tech. 547 Figure Tech. 5-26 EGSM900 CCBs with control boards fitted . . . . . . . . . . . . . . Tech. 549 Figure Tech. 5-27 DCS1800 CCBs with control boards fitted . . . . . . . . . . . . . . . Tech. 550 Figure Tech. 5-28 CCB configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 550 Figure Tech. 5-29 Functional diagram of CCB . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 551 Figure Tech. 6-1 Digital and BPSM module locations, including optional redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 63 Figure Tech. 6-2 Digital module and transceiver connections . . . . . . . . . . . . . . Tech. 65 Figure Tech. 6-3 View of the MCUF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 67 Figure Tech. 6-4 Functional diagram of MCUF in MCUF mode . . . . . . . . . . . . . Tech. 68 Figure Tech. 6-5 View of NIU module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 617 Figure Tech. 6-6 Functional diagram of NIU module . . . . . . . . . . . . . . . . . . . . . . Tech. 618 Figure Tech. 6-7 Diagram of T43 connection to NIUs . . . . . . . . . . . . . . . . . . . . . Tech. 622 Figure Tech. 6-8 View of the FMUX module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 623 Figure Tech. 6-9 Functional diagram of FMUX module . . . . . . . . . . . . . . . . . . . . Tech. 624 Figure Tech. 6-10 Alarm module view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 625 Figure Maint. 1-1 Removing and fitting the stacking bracket front cover . . . . . Maint. 19
Service Manual: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
xv
GSM
Figure Maint. 1-2 Cabinet modules with door and hood removed . . . . . . . . . . . Maint. 112 Figure Maint. 1-3 Diagram of cabinet with expanded view of CBM . . . . . . . . . . Maint. 116 Figure Maint. 2-1 Cabinet, without door or hood, showing FRU components . Maint. 25 Figure Maint. 2-2 Inside and outside views of door . . . . . . . . . . . . . . . . . . . . . . . Maint. 27 Figure Maint. 2-3 Hood view when placed on top of cabinet . . . . . . . . . . . . . . . Maint. 210 Figure Maint. 2-4 Stacking bracket view with optional CCB basket . . . . . . . . . . Maint. 211 Figure Maint. 2-5 View of fan modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 213 Figure Maint. 2-6 Views of CBM with circuit breaker buttons identified . . . . . . Maint. 215 Figure Maint. 2-7 View of PSM with key features identified . . . . . . . . . . . . . . . . Maint. 217 Figure Maint. 2-8 Connecting battery isolation jumper lead . . . . . . . . . . . . . . . . Maint. 220 Figure Maint. 2-9 CTU view with key features . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 221 Figure Maint. 2-10 CTU2 view with key features . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 222 Figure Maint. 2-11 View of a later type single band SURF module . . . . . . . . . . Maint. 262 Figure Maint. 2-12 Views of typical Tx block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 266 Figure Maint. 2-13 CCBs in installed position with CCB basket bar attached . Maint. 269 Figure Maint. 2-14 Digital and BPSM module locations including optional redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 272 Figure Maint. 2-15 Horizonmacro GCLK calibration cable connections . . . . . . Maint. 280 Figure Maint. 3-1 Horizonmacro 9-way to 9-way hardware verification cable connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 35 Figure Maint. 3-2 Horizonmacro 9-way to 9-way transceiver cable connections . . . . . . Maint. 36 Figure Maint. 4-1 Diagram of indoor cabinet showing major FRUs . . . . . . . . . . Maint. 44 Figure Maint. 4-2 CCBs in installed position with CCB basket bar attached . . Maint. 47 Figure Maint. 4-3 Digital module and BPSM locations . . . . . . . . . . . . . . . . . . . . . Maint. 48 Figure Maint. 4-4 Internal and external view of the door . . . . . . . . . . . . . . . . . . . Maint. 49 Figure Maint. 4-5 View of the hood as seen from the front of the cabinet . . . . Maint. 410
xvi
29 Jan 2007
GSM
List of Tables
Table Tech. 1-1 Main components of Horizonmacro and M-Cell6 . . . . . . . . . . Tech. 110 Table Tech. 1-2 Horizonmacro specification compliance . . . . . . . . . . . . . . . . . . Tech. 111 Table Tech. 1-3 Environmental limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 111 Table Tech. 1-4 Main indoor cabinet power supply requirements . . . . . . . . . . . Tech. 112 Table Tech. 1-5 Power consumption of full cabinet, including digital redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 112 Table Tech. 1-6 CTU RF power output at cabinet after Tx blocks . . . . . . . . . . . Tech. 113 Table Tech. 1-7 CTU2 RF power output at cabinet after Tx blocks . . . . . . . . . Tech. 113 Table Tech. 1-8 Rx sensitivity * . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 114 Table Tech. 1-9 Cabinet dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 114 Table Tech. 1-10 Main indoor cabinet weights (with six transceivers) . . . . . . . Tech. 115 Table Tech. 1-11 Torque values for all cabinet screws/bolts and RF connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 115 Table Tech. 1-12 Frequency band characteristics GSM/EGSM900 and DCS1800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 116 Table Tech. 1-13 Frequency band characteristics GSM850 and PCS1900 . Tech. 117 Table Tech. 2-1 External alarms indoor pin shorts (37-way D-type) . . . . . . . . . Tech. 214 Table Tech. 2-2 GPS pin connections (15-way D-type) . . . . . . . . . . . . . . . . . . . Tech. 214 Table Tech. 2-3 CCB pin connections (15-way D-type) . . . . . . . . . . . . . . . . . . . Tech. 215 Table Tech. 2-4 BIB interconnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 216 Table Tech. 2-5 T43 interconnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 217 Table Tech. 2-6 PIX0 pin connections (37-way D-type) . . . . . . . . . . . . . . . . . . . Tech. 218 Table Tech. 2-7 PIX1 pin connections (37-way D-type) . . . . . . . . . . . . . . . . . . . Tech. 219 Table Tech. 2-8 ICS pin connections (25-way D-type) . . . . . . . . . . . . . . . . . . . . Tech. 219 Table Tech. 4-1 Input currents for power supply module . . . . . . . . . . . . . . . . . . Tech. 44 Table Tech. 4-2 PSM operational configurations, CTUs only . . . . . . . . . . . . . . . Tech. 45 Table Tech. 4-3 PSM operational configurations, CTU/CTU2 combinations . . Tech. 45 Table Tech. 4-4 Power supply module LEDs function . . . . . . . . . . . . . . . . . . . . . Tech. 46 Table Tech. 4-5 Hold-up battery module specifications . . . . . . . . . . . . . . . . . . . Tech. 48 Table Tech. 5-1 CTU front panel status indicators . . . . . . . . . . . . . . . . . . . . . . . . Tech. 512 Table Tech. 5-2 CTU front panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 514 Table Tech. 5-3 CTU2 front panel status indicators . . . . . . . . . . . . . . . . . . . . . . . Tech. 518 Table Tech. 5-4 CTU2 front panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 520 Table Tech. 5-5 Comparison between GPRS and EGPRS . . . . . . . . . . . . . . . . Tech. 523 Table Tech. 6-1 Full size and half size digital modules . . . . . . . . . . . . . . . . . . . . Tech. 64 Table Tech. 6-2 MCUF front panel LED indication . . . . . . . . . . . . . . . . . . . . . . . . Tech. 610 Table Tech. 6-3 NIU slot and equivalent command identity . . . . . . . . . . . . . . . . Tech. 616
Service Manual: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
xvii
GSM
Table Tech. 6-4 NIU LED display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 617 Table Tech. 6-5 T43/BIB connector to NIU boards . . . . . . . . . . . . . . . . . . . . . . . Tech. 621 Table Tech. 6-6 Alarm module LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tech. 627 Table Maint. 1-1 Routine maintenance schedule . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 14 Table Maint. 1-2 Horizonmacro indoor tool list . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 15 Table Maint. 1-3 Fan positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 111 Table Maint. 1-4 Normal LED indication of cabinet modules . . . . . . . . . . . . . . . Maint. 113 Table Maint. 1-5 BS7671 (16th edition) Table 71A (part of) . . . . . . . . . . . . . . . . Maint. 115 Table Maint. 2-1 Torque values for all cabinet screws/bolts and RF connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 24 Table Maint. 2-2 Fan positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 214 Table Maint. 2-3 Transceiver calibration scenarios and procedures . . . . . . . . Maint. 227 Table Maint. 2-4 Transceiver calibration commands . . . . . . . . . . . . . . . . . . . . . . Maint. 229 Table Maint. 2-5 MMI commands for CTU bay level offset calibration . . . . . . . Maint. 237 Table Maint. 2-6 GSM850 CTU test frequencies . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 242 Table Maint. 2-7 EGSM900 CTU test frequencies . . . . . . . . . . . . . . . . . . . . . . . . Maint. 242 Table Maint. 2-8 DCS1800 CTU test frequencies . . . . . . . . . . . . . . . . . . . . . . . . Maint. 243 Table Maint. 2-9 PCS1900 CTU test frequencies . . . . . . . . . . . . . . . . . . . . . . . . Maint. 244 Table Maint. 2-10 CTU frequency offset addresses (GSM850) . . . . . . . . . . . . . Maint. 249 Table Maint. 2-11 CTU frequency offset addresses (EGSM900) . . . . . . . . . . . Maint. 250 Table Maint. 2-12 CTU frequency offset addresses (DCS1800) . . . . . . . . . . . . Maint. 250 Table Maint. 2-13 CTU frequency offset addresses (PCS1900) . . . . . . . . . . . . Maint. 251 Table Maint. 2-14 MMI commands for CTU2 Rx bay level offset calibration . . Maint. 252 Table Maint. 2-15 EGSM900 CTU2 test frequencies . . . . . . . . . . . . . . . . . . . . . Maint. 259 Table Maint. 2-16 DCS1800 CTU2 test frequencies . . . . . . . . . . . . . . . . . . . . . . Maint. 260 Table Maint. 2-17 Connectors for each type of Tx block module . . . . . . . . . . . Maint. 267 Table Maint. 3-1 Hardware verification equipment . . . . . . . . . . . . . . . . . . . . . . . . Maint. 34 Table Maint. 3-2 Test plug pin connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 36 Table Maint. 3-3 CTU VSWR and power calibration commands . . . . . . . . . . . . Maint. 39 Table Maint. 3-4 CTU2 power calibration commands . . . . . . . . . . . . . . . . . . . . . Maint. 310 Table Maint. 3-5 Achievable Tx RF power output . . . . . . . . . . . . . . . . . . . . . . . . Maint. 319 Table Maint. 3-6 CTU2 Tx power offsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 323 Table Maint. 3-7 Switch settings for example of value 75 . . . . . . . . . . . . . . . . . Maint. 326 Table Maint. 3-8 Achievable Tx RF power output . . . . . . . . . . . . . . . . . . . . . . . . Maint. 330 Table Maint. 3-9 CTU 900 CCB cavity tuning commands . . . . . . . . . . . . . . . . . Maint. 331 Table Maint. 3-10 CTU 1800 CCB cavity tuning commands . . . . . . . . . . . . . . . Maint. 331 Table Maint. 3-11 CTU 900 and CTU 1800 CCB cavity parking commands . . Maint. 331 Table Maint. 4-1 List of Horizonmacro indoor spares . . . . . . . . . . . . . . . . . . . . . Maint. 45
Service Manual: Horizonmacro indoor 68P02902W06-C006
xviii
29 Jan 2007
GSM
Table Maint. 4-2 CCB and stacking bracket spares . . . . . . . . . . . . . . . . . . . . . . Maint. 47 Table Maint. 4-3 Digital module and BPSM spares . . . . . . . . . . . . . . . . . . . . . . . Maint. 48 Table Maint. 4-4 Door spare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 49 Table Maint. 4-5 Indoor hood spare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maint. 410
68P02902W06-C006
xix
GSM
xx
29 Jan 2007
GSM
Version information
The following table lists the versions of this manual in order of manual issue: Manual issue
O A B
Date of issue
03 Jun 1999 15 Oct 1999 29 May 2002 Original issue.
Remarks
Updated to include details for EGSM900. Includes redesigned component information (e.g. SURF, internal fans and packaging). Optimization information added. Updated to new service manual format. CTU2, AMR and EGPRS information added.
C C005 C006
GMR Number
N/A N/A N/A N/A N/A
Remarks
References to snd cmb command replaced by send eqcp in the CCB cavities tuning procedure. Variations observed between the output of the two carriers in a CTU2. Replacement of an analog wattmeter with a digital wattmeter for calibrating a base station. Amendment to the GCLK calibration procedure. Replaced content in subsection NIU command identity number of section NIU.
Incorporation of CDCNs
CDCN Number 02W06001 Remarks Revised few sections of Chapter 3 to provide documentation support for a CQSR delivery. Revised table 31 of Category 523.
02W06004
68P02902W06-C006
GSM
Remarks Amendments to GCLK calibration procedure. Replaced content above Tech. Table 63 of Category Technical Description.
29 Jan 2007
GSM
General information
General information
Important notice
If this manual was obtained when attending a Motorola training course, it will not be updated or amended by Motorola. It is intended for TRAINING PURPOSES ONLY. If it was supplied under normal operational circumstances, to support a major software release, then corrections will be supplied automatically by Motorola in the form of General Manual Revisions (GMRs).
Purpose
Motorola cellular communications manuals are intended to instruct and assist personnel in the operation, installation and maintenance of the Motorola cellular infrastructure equipment and ancillary devices. It is recommended that all personnel engaged in such activities be properly trained by Motorola.
WARNING
Failure to comply with Motorolas operation, installation and maintenance instructions may, in exceptional circumstances, lead to serious injury or death.
These manuals are not intended to replace the system and equipment training offered by Motorola, although they can be used to supplement and enhance the knowledge gained through such training.
Gain an overview of the equipment and interconnection of components. Understand the function and operation of all components. Recognize configurations, and equivalent module functions to M-Cell6 (an interchangeable previous cabinet). Be aware of the warnings (potential for harm to people) and cautions (potential for harm to equipment) to be observed when working on the equipment. Understand how to inspect and maintain the equipment. Have a clear ready reference for all dedicated information in one manual. NOTE
The Horizonmacro indoor service manual no longer contains installation and commissioning information. Refer to
S S
68P02902W06-C006
General information
GSM
Feature references
Most of the manuals in the set, of which this manual is part, are revised to accommodate features released at Motorola General System Releases (GSRn) or GPRS Support Node (GSNn) releases. In these manuals, new and amended features are tagged to help users to assess the impact on installed networks. The tags are the appropriate Motorola Roadmap DataBase (RDB) numbers or Research and Development Prioritization (RDP) numbers. The tags include index references which are listed in the manual Index. The Index includes the entry feature which is followed by a list of the RDB or RDP numbers for the released features, with page references and hot links in electronic copy. The tags have the format: {nnnn} or {nnnnn} Where: {nnnn} {nnnnn} The tags are positioned in text as follows: New and amended feature information New sentence/s or new or amended text. Complete new blocks of text as follows: S Full sections under a main heading S Full paragraphs under subheadings Tag position in text Immediately before the affected text. Immediately after the headings as follows: S Main heading S Subheading is: the RDB number the RDP number
New or amended complete Figures and Tables Warning, Caution and Note boxes. General command syntax, operator input or displays (in special fonts).
After the Figure or Table number and before the title text. Immediately before the affected text in the box. On a separate line immediately above the affected item.
For a list of Roadmap numbers and the RDB or RDP numbers of the features included in this software release, refer to the manual System Information: GSM Overview (68P02901W01), or to the manual System Information: GPRS Overview (68P02903W01).
29 Jan 2007
GSM
General information
Data encryption
In order to avoid electronic eavesdropping, data passing between certain elements in the GSM and GPRS network is encrypted. In order to comply with the export and import requirements of particular countries, this encryption occurs at different levels as individually standardised, or may not be present at all in some parts of the network in which it is normally implemented. The manual set, of which this manual is a part, covers encryption as if fully implemented. Because the rules differ in individual countries, limitations on the encryption included in the particular software being delivered, are covered in the Release Notes that accompany the individual software release.
Cross references
Throughout this manual, cross references are made to the chapter numbers and section names. The section name cross references are printed bold in text. This manual is divided into uniquely identified and numbered chapters that, in turn, are divided into sections. Sections are not numbered, but are individually named at the top of each page, and are listed in the table of contents.
Text conventions
The following conventions are used in the Motorola cellular infrastructure manuals to represent keyboard input text, screen output text and special key sequences.
Input
Characters typed in at the keyboard are shown like this.
Output
Messages, prompts, file listings, directories, utilities, and environmental variables that appear on the screen are shown like this.
68P02902W06-C006
GSM
Procedure
Whenever a safety issue arises: 1. 2. 3. Make the equipment concerned safe, for example by removing power. Make no further attempt to adjust or rectify the equipment. Report the problem directly to the Customer Network Resolution Centre, Swindon +44 (0)1793 565444 or China +86 10 68437733 (telephone) and follow up with a written report by fax, Swindon +44 (0)1793 430987 or China +86 10 68423633 (fax). Collect evidence from the equipment under the guidance of the Customer Network Resolution Centre.
4.
29 Jan 2007
GSM
Warnings
Definition of Warning
A warning is used to alert the reader to possible hazards that could cause loss of life, physical injury, or ill health. This includes hazards introduced during maintenance, for example, the use of adhesives and solvents, as well as those inherent in the equipment.
Do not look directly into fibre optic cables or data in/out connectors. Laser radiation can come from either the data in/out connectors or unterminated fibre optic cables connected to data in/out connectors.
Cautions
Definition of Caution
A caution means that there is a possibility of damage to systems, software or individual items of equipment within a system. However, this presents no danger to personnel.
Do not use test equipment that is beyond its due calibration date; arrange for calibration to be carried out.
68P02902W06-C006
General warnings
GSM
General warnings
Introduction
Observe the following specific warnings during all phases of operation, installation and maintenance of the equipment described in the Motorola manuals:
S S S S S S S S
Potentially hazardous voltage Electric shock RF radiation Laser radiation Heavy equipment Parts substitution Battery supplies Lithium batteries
Failure to comply with these warnings, or with specific warnings elsewhere in the Motorola manuals, violates safety standards of design, manufacture and intended use of the equipment. Motorola assumes no liability for the customers failure to comply with these requirements.
Warning labels
Warnings particularly applicable to the equipment are positioned on the equipment. Personnel working with or operating Motorola equipment must comply with any warning labels fitted to the equipment. Warning labels must not be removed, painted over or obscured in any way.
29 Jan 2007
GSM
General warnings
Specific warnings
Specific warnings used throughout the GSM manual set are shown below. These will be incorporated into procedures as applicable. These must be observed by all personnel at all times when working with the equipment, as must any other warnings given in text, in the illustrations and on the equipment.
This equipment operates from a hazardous voltage of 230 V ac single phase or 415 V ac three phase supply. To achieve isolation of the equipment from the ac supply, the ac input isolator must be set to off and locked.
When working with electrical equipment, reference must be made to the Electricity at Work Regulations 1989 (UK), or to the relevant electricity at work legislation for the country in which the equipment is used.
NOTE
Electric shock
WARNING
Do not touch the victim with your bare hands until the electric circuit is broken. Switch off. If this is not possible, protect yourself with dry insulating material and pull or push the victim clear of the conductor. ALWAYS send for trained first aid or medical assistance IMMEDIATELY.
In cases of low voltage electric shock (including public supply voltages), serious injuries and even death, may result. Direct electrical contact can stun a casualty causing breathing, and even the heart, to stop. It can also cause skin burns at the points of entry and exit of the current. In the event of an electric shock it may be necessary to carry out artificial respiration. ALWAYS send for trained first aid or medical assistance IMMEDIATELY. If the casualty is also suffering from burns, flood the affected area with cold water to cool, until trained first aid or medical assistance arrives.
68P02902W06-C006
General warnings
GSM
RF radiation
WARNING
High RF potentials and electromagnetic fields are present in this equipment when in operation. Ensure that all transmitters are switched off when any antenna connections have to be changed. Do not key transmitters connected to unterminated cavities or feeders.
Relevant standards (USA and EC), to which regard should be paid when working with RF equipment are:
S
ANSI IEEE C95.1-1991, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. CENELEC 95 ENV 50166-2, Human Exposure to Electromagnetic Fields High Frequency (10 kHz to 300 GHz).
Laser radiation
WARNING
Do not look directly into fibre optic cables or optical data in/out connectors. Laser radiation can come from either the data in/out connectors or unterminated fibre optic cables connected to data in/out connectors.
Lifting equipment
WARNING
When dismantling heavy assemblies, or removing or replacing equipment, a competent responsible person must ensure that adequate lifting facilities are available. Where provided, lifting frames must be used for these operations.
When dismantling heavy assemblies, or removing or replacing equipment, the competent responsible person must ensure that adequate lifting facilities are available. Where provided, lifting frames must be used for these operations. When equipments have to be manhandled, reference must be made to the Manual Handling of Loads Regulations 1992 (UK) or to the relevant manual handling of loads legislation for the country in which the equipment is used.
10
29 Jan 2007
GSM
General warnings
Parts substitution
WARNING
Do not install substitute parts or perform any unauthorized modification of equipment, because of the danger of introducing additional hazards.Contact Motorola if in doubt to ensure that safety features are maintained.
Battery supplies
WARNING
Do not wear earth straps when working with standby battery supplies.
Lithium batteries
WARNING
Lithium batteries, if subjected to mistreatment, may burst and ignite. Defective lithium batteries must not be removed or replaced. Any boards containing defective lithium batteries must be returned to Motorola for repair.
Contact your local Motorola office for how to return defective lithium batteries.
68P02902W06-C006
11
General cautions
GSM
General cautions
Introduction
Observe the following cautions during operation, installation and maintenance of the equipment described in the Motorola manuals. Failure to comply with these cautions or with specific cautions elsewhere in the Motorola manuals may result in damage to the equipment. Motorola assumes no liability for the customers failure to comply with these requirements.
Caution labels
Personnel working with or operating Motorola equipment must comply with any caution labels fitted to the equipment. Caution labels must not be removed, painted over or obscured in any way.
Specific cautions
Cautions particularly applicable to the equipment are positioned within the text of this manual. These must be observed by all personnel at all times when working with the equipment, as must any other cautions given in text, on the illustrations and on the equipment.
Fibre optics
CAUTION
Fibre optic cables must not be bent in a radius of less than 30 mm.
Static discharge
CAUTION
Motorola equipment contains CMOS devices. These metal oxide semiconductor (MOS) devices are susceptible to damage from electrostatic charge. See the section Devices sensitive to static in the preface of this manual for further information.
12
29 Jan 2007
GSM
Always wear an earth strap which must be connected to the electrostatic point (ESP) on the equipment. Leave the short circuit on the leads until the last moment. It may be necessary to replace the conductive foam by a piece of wire to enable the device to be fitted. Do not wear outer clothing made of nylon or similar man made material. A cotton overall is preferable. If possible work on an earthed metal surface or anti-static mat. Wipe insulated plastic work surfaces with an anti-static cloth before starting the operation. All metal tools should be used and when not in use they should be placed on an earthed surface. Take care when removing components connected to electrostatic sensitive devices. These components may be providing protection to the device.
S S
S S
When mounted onto printed circuit boards (PCBs), MOS devices are normally less susceptible to electrostatic damage. However PCBs should be handled with care, preferably by their edges and not by their tracks and pins, they should be transferred directly from their packing to the equipment (or the other way around) and never left exposed on the workbench.
68P02902W06-C006
13
GSM
On the Motorola service web. (https://mynetworksupport.motorola.com/index.asp). CD-ROM library produced in support of a major system software release.
The following are the generic manuals in the GSM manual set, these manuals are release dependent: The CD-ROM does not include Release Notes or documentation supporting specialist products such as MARS or COP.
Ordering manuals
The Motorola 68P order (catalogue) number is used to order manuals. All orders for Motorola manuals must be placed with your Motorola Local Office or Representative. Manuals are ordered using the order (catalogue) number.
14
29 Jan 2007
GSM
GMR amendment
GMR amendment
Introduction to GMRs
Changes to a manual that occur after the printing date are incorporated into the manual using General Manual Revisions (GMRs). GMRs are issued to correct Motorola manuals as and when required. A GMR has the same identity as the target manual. Each GMR is identified by a number in a sequence that starts at 01 for each manual at each issue.
GMR availability
GMRs are published as follows:
S
Printed hard copy - Complete replacement content or loose leaf pages with amendment list. Remove and replace pages in this manual, as detailed on the GMR instruction sheet.
S S
Motorola service web - Updated at the same time as hard copies. CD-ROM - Updated periodically as required.
68P02902W06-C006
15
68P02902W06-C006
GSM
ii
29 Jan 2007
CHAP RF MO
29 Jan 2007
68P02902W06-C006
iii
GSM
CHAPTER 5 RF MODULES
iv
29 Jan 2007
CHAP RF MO
GSM
68P02902W06-C006
GSM
vi
29 Jan 2007
Chapter 1
68P02902W06-C006
Tech. 11
GSM
Tech. 12
29 Jan 2007
GSM
ig.225.rh
68P02902W06-C006
Tech. 13
GSM
A digital module shelf, located in the lower right side of the cabinet. This contains master and optional redundant digital modules: Fibre optic multiplexer (FMUX), 1 + 1 redundant (if required). Main control unit with dual FMUX (MCUF), 1 + 1 redundant (if required). Network interface units (NIUs), four in total. An alarm board (no redundancy option). One or two (for redundancy) mBCU power supply modules (BPSMs).
Up to three power supply modules (PSMs) and one circuit breaker module (CBM) in the upper right portion of the cabinet. The PSMs are load sharing, with the third PSM providing optional redundancy. Up to six compact transceiver units (CTUs), located in the left side of the cabinet. NOTE
CTUs may be replaced by CTU2s (with restrictions).
S S
Fan modules mounted in the bottom of the cabinet, two 2-fan modules and one 4-fan module. RF modules, mounted in the top panel, comprising transmit (Tx) blocks, and a receive (Rx) module, the sectorized universal receiver front-end (SURF). The various Tx blocks are listed in Specifications in this chapter. Interface panel, mounted in the top panel, for power and customer communications connectors.
Tech. 14
29 Jan 2007
GSM
Figure Tech. 1-2 Cabinet with components identified (door and base plinth removed)
RF MODULES
ONE SURF (Rx) THREE Tx BLOCKS (DCFs SHOWN AS EXAMPLE) SIX TRANSCEIVERS (CTU/CTU2s)
ALARM MODULE
DIGITAL MODULES
MCUF FMUX/NIU/BPSM (NOT VISIBLE) TOP SECTION OF PLINTH (SLIDES INTO BASE PLINTH)
NOTE
Three PSMs = 2 + 1 redundant (if required). An optional hold-up battery module may be installed instead of a redundant PSM.
68P02902W06-C006
Tech. 15
GSM
Configuration information
Configuration information can be found in System Information: BSS Equipment Planning (68P02900W21).
Technical Description Provides an introduction, specifications, and technical descriptions of all components.
Maintenance and Parts Provides information on maintenance and repair, with procedures to change field replaceable units (FRUs). Lists of options and spares, with diagrams to illustrate FRUs, are also included.
Each section is divided into chapters. The information in each chapter is grouped according to functionality, as shown in Figure Tech. 1-2. NOTE
Installation information for the Horizonmacro indoor is not provided in this manual (refer to Installation and Configuration, (68P02902W08) for installation and configuration information).
Tech. 16
29 Jan 2007
GSM
68P02902W06-C006
Tech. 17
GSM
EXT
0A
0B Rx0
1A
1B Rx1
2A Rx2
2B Rx FILTER Tx FILTER
SURF
UP TO THREE Tx BLOCKS
Rx A
Rx B
RF LOOPBACK Tx
UP TO SIX TRANSCEIVERS
2 2 2
MCUF
NIU
NIU
NIU
NIU
TO NETWORK
Tech. 18
29 Jan 2007
GSM
68P02902W06-C006
Tech. 19
GSM
Main processor board (formerly GPROC, KSW and GCLK boards in BTS4/5/6 (pre-M-Cell) equipment) Connection radio to MCU
Backplane
FOX FMUX
Connection MCU to MCUF internal FMUX transceivers in another cabinet (two) or external FMUX (one) Rx components and distribution Radio to Rx components Tx components Links to terrestrial network E1/T1 links Power for digital boards SURF SURF Harness DCF, TDF, DDF, HCU and CCB NIU T43/BIB BPSM
DNLB & IADU Cables CBF, MPDM, HPDM HC and CCB NIU T43/BIB BPSM
NOTE
The original CTU may be replaced by the later CTU2, as used in the Horizon II macro.
Tech. 110
29 Jan 2007
GSM
Specifications
Specifications
Overview of specifications
All Horizonmacro specifications are included in this section.
Software requirements
The GSM/EGSM900 and DCS1800 BTSs require software release GSR4 (or later) in the network. The GSM850 and PCS1900 BTSs require software release GSR5.1 (or later) in the network. If any CTUs have been replaced by CTU2s in the cabinet, BSS and OMC-R software release GSR6 (Horizon II) or later is required in the network.
EMC
Environmental limits
Table Tech. 1-3 lists the operating and storage environmental limits.
Table Tech. 1-3 Environmental limits Environment Operating Storage Temperature 5 _C to +45 _C. 45 _C to +70 _C. Relative Humidity 5% to 100% relative humidity, not to exceed 0.029 g water/m3 dry air. 8% to 100% relative humidity, not to exceed 0.029 g water/m3 dry air.
NOTE
This specification is valid up to 3 km altitude, corresponding to an atmospheric pressure range of 648 millibars to 1048 millibars.
68P02902W06-C006
Tech. 111
Specifications
GSM
Power requirements
Cabinet power supply requirements
Table Tech. 1-4 lists the power supply requirements for the different power supply options.
Table Tech. 1-4 Main indoor cabinet power supply requirements Nominal Voltage Voltage supply range Current supply maximum (at nominal voltage) 6 x CTUs 6 x CTU2s
64 A 36 A 7.5 A
Power consumption
Table Tech. 1-5 lists typical and maximum cabinet power consumption values (excluding power supplies) when either CTUs or CTU2s are installed in the cabinet.
Table Tech. 1-5 Power consumption of full cabinet, including digital redundancy Configuration Typical measured consumption Maximum power consumption
6 x CTUs 6 x CTU2s
1400 W 1960 W
1700 W 2700 W
NOTE
Maximum power consumption figures are theoretical values derived under extreme conditions and are affected by variables such as temperature, component tolerances, transmission power and supply voltage. Although these figures must be considered when planning site power requirements, typical measured consumption values will be lower.
Tech. 112
29 Jan 2007
GSM
Specifications
RF power output
Table Tech. 1-6 lists the expected power output from the various Tx blocks for the CTU transceiver.
Table Tech. 1-6 CTU RF power output at cabinet after Tx blocks Tx block TDF DCF DDF1 CCB2 GSM850 EGSM900 DCS1800 PCS1900
1 Assumes the highest loss DDF path, i.e. two stages of hybrid combining in the DDF. Refer to configuration diagrams in Installation and Configuration: Horizonmacro indoor (68P02902W08) for additional details. 2 For a six-channel configuration with minimum cavity separation of 800 kHz. NOTE
CCBs are not currently available for the GSM850 or PCS1900 variants.
Table Tech. 1-7 lists the expected RF power output from the various Tx blocks for low and high band CTU2s in a Horizonmacro indoor cabinet for single carrier and dual carrier GMSK and single carrier 8-PSK modes.
Table Tech. 1-7 CTU2 RF power output at cabinet after Tx blocks Tx block TDF Mode EGSM900 DCS1800
DCF
DDF1
CCB
Dual carrier GMSK Single carrier GMSK Single carrier 8-PSK Dual carrier GMSK Single carrier GMSK Single carrier 8-PSK Dual carrier GMSK Single carrier GMSK Single carrier 8-PSK Cannot
10 W (40.0 dBm) 10 W (40.0 dBm) 40 W (46.0 dBm) 32 W (45.0 dBm) 20 W (43.0 dBm) 16 W (42.0 dBm) 5 W (37.0 dBm) 5 W (37.0 dBm) 20 W (43.0 dBm) 16 W (42.0 dBm) 10 W (40.0 dBm) 8 W (39.0 dBm) 2.2 W (33.5 dBm) 2.2 W (33.5 dBm) 8.5 W (39.3 dBm) 7.1 W (38.5 dBm) 4.5 W (36.5 dBm) 3.5 W (35.5 dB) be used with CTU2s.
1 Assumes the highest loss DDF path, i.e. two stages of hybrid combining in the DDF. Refer to configuration diagrams in Installation and Configuration: Horizonmacro indoor (68P02902W08) for additional details.
NOTE
All power levels are average power per carrier, measured to ETSI 05.05 at the BTS antenna port. All are to be within ETSI tolerances over frequency and temperature. The Horizonmacro indoor requires 3 PSUs when more than 4 CTU and CTU2 transceivers are used. PSU redundancy is not available in these configurations.
68P02902W06-C006
Tech. 113
Specifications
GSM
Sensitivity
The receive sensitivity of the equipment is shown in Table Tech. 1-8.
Table Tech. 1-8 Rx sensitivity * Frequency Band Without Duplexer With Duplexer
* Guaranteed over all channel types, fading profiles, RF frequencies and operating conditions.
Battery backup
The Horizonmacro indoor cabinet has no internal battery backup as standard. An optional hold-up battery module, (sufficient to provide ten seconds of backup power), can be fitted in the PSM shelf, in an empty slot or in place of the redundant PSM. The optional hold-up battery module is described in Chapter 4 of this manual in Hold-up battery module. Additional battery backup capacity can be provided by installation of an optional battery back up system, described in Service manual: Battery backup system for Horizonmacro indoor 68P02900W59.
The optional hood allows cables to enter the cabinet from the back and above. The stacking bracket allows a second cabinet to be stacked on top of the first cabinet. The stacking bracket can also contain a metal basket, in which CCBs are fitted (the only Tx unit that cannot fit in the cabinet itself).
Technical Description: Horizonmacro indoor 68P02902W06-C006
Tech. 114
29 Jan 2007
GSM
Specifications
Weights
The maximum weight of the cabinet is shown in Table Tech. 1-10. CAUTION
Consider future expansion. Another cabinet may be added by stacking on top of the existing cabinet. This, if used with stacking units on both, each with CCBs, and associated cables, could result in a total weight of 280 kg. Ensure floor is capable of supporting this weight.
Table Tech. 1-10 Main indoor cabinet weights (with six transceivers) Cabinet with plinth and optional hood Cabinet with plinth, stacking bracket and CCB
115 kg
130 kg
Torque values
Table Tech. 1-11 details torque values used during installation, maintenance and repair procedures.
Table Tech. 1-11 Torque values for all cabinet screws/bolts and RF connectors Size of screw/bolt M4 M6 M8 M10 SMA N-type 7/16
Torque value
2.2 Nm
3.4 Nm
5 Nm
10 Nm
1 Nm
3.4 Nm
25 Nm
NOTE
Torque values used with M12 anchor bolts will depend on the anchor bolt manufacturer. Check manufacturers data for correct values.
68P02902W06-C006
Tech. 115
Specifications
GSM
Frequency capability
Frequency hopping
The Horizonmacro supports baseband frequency hopping (BBH) and synthesizer frequency hopping (SFH). NOTE
Baseband frequency hopping (BBH) is not supported in the GSM850 and PCS1900 Horizonmacro variants. In addition, BBH is not possible using CTU2s in double density mode in a Horizonmacro cabinet which is controlled by a MCUF site controller (refer to System Information: BSS Equipment Planning (68P02900W21) for further details).
Tech. 116
29 Jan 2007
GSM
Specifications
Table Tech. 1-13 Frequency band characteristics GSM850 and PCS1900 GSM850 Transmit frequency band (MHz) Receive frequency band (MHz) Transmit/receive duplex separation (MHz) Channel width (kHz) Number of channels Transmit frequency guard bands (MHz) Receive frequency guard bands (MHz) Transmit channel centre frequency (MHz) 869 to 894 824 to 849 45 200 124 869.0 to 869.1 893.9 to 894.0 824.0 to 824.1 848.9 to 849.0 Even 10ths of a MHz from 869.2 to 893.8 Even 10ths of a MHz from 824.2 to 848.8 PCS1900 1930 to 1990 1850 to 1910 80 200 299 1930.0 to 1930.1 1989.9 to 1990.0 1850.0 to 1850.1 1909.9 to 1910.0 Even 10ths of a MHz from 1930.2 to 1989.8 Even 10ths of a MHz from 1850.2 to 1909.8
68P02902W06-C006
Tech. 117
Specifications
GSM
Structural considerations
Adequate clearance must be provided at the front of the equipment for operation and maintenance purposes. There must be adequate side clearance (50 mm) to enable the door to open beyond 90 (see Figure Tech. 1-6). The door can also stop at 95 and 130 , but this is only to protect the door, or give optional additional operator space. The cabinet ventilation entry can be solely from the bottom front of the cabinet. This allows a cabinet to be placed against a wall. However, if the unit is placed 50 mm from back or side obstructions, such as wall or other cabinets, the ventilation will be improved, and fan noise reduced. Up to 100 mm rear space may be required for cables if using stacking bracket. The foundation or structure on which the BTS cabinet is mounted must be of sufficient strength to support a maximum gross weight of 130 kg for a single cabinet or 280 kg for two stacked cabinets. NOTE
In seismically active areas, Motorola suggest using a qualified structural engineer to assess frame mounting requirements, such as floor construction, mounting anchors, cell site construction and to provide a suitable design for top frame support if a stacked configuration is required.
Layout plan
Figure Tech. 1-6 shows the cabinet installation layout plan. Figure Tech. 1-6 Indoor cabinet site layout plan
100 mm clearance if using stacking bracket to allow cable space 50 mm minimum side clearance for door opening INDOOR CABINET 70 mm width when door at 95 500 mm width when door at 130 430 mm 700 mm
Tech. 118
29 Jan 2007
Chapter 2
Cabinet structure
68P02902W06-C006
Tech. 21
GSM
Tech. 22
29 Jan 2007
GSM
68P02902W06-C006
Tech. 23
GSM
Top panel
This section describes the bare top panel with all the modules removed.
Tech. 24
29 Jan 2007
GSM
Figure Tech. 2-2 Cabinet, without door or hood, showing main components
RF MODULES
ONE SURF (Rx) THREE Tx BLOCKS (DCFs SHOWN AS EXAMPLE) SIX TRANSCEIVERS (CTU/CTU2s)
ALARM MODULE
DIGITAL MODULES
MCUF FMUX/NIU/BPSM (NOT VISIBLE) TOP SECTION OF PLINTH (SLIDES INTO BASE PLINTH)
68P02902W06-C006
Tech. 25
GSM
Three connectors to the SURF, for RF and power. One RF connector to each transceiver, consisting of three inputs, one each for RxA, RxB and RF loopback test, as shown in Figure Tech. 2-4. The RF connectors are free floating to ensure fitting of transceiver modules. One connector to the backplane, for power from the PSMs.
ig.232.rh
Tech. 26
29 Jan 2007
GSM
TRANSCEIVER 5
68P02902W06-C006
Tech. 27
Top panel
GSM
Top panel
Top panel description
The top panel provides:
S
A basket to hold up to three Tx blocks. This includes three holes to enable connection of CTU/CTU2 Tx cables to the underside of each Tx block. The holes also allow cooling of the Tx blocks from underneath. A slot for insertion of the SURF module. A location hole for the interface panel. An area for ventilation purposes above the PSMs. A cable hole for fibre optic extension cables from the MCUF FMUX to an FMUX of another cabinet.
S S S S
Tech. 28
29 Jan 2007
GSM
The main cage - providing compartments for fans, transceivers, digital modules, BPSMs, PSMs and CBM. The backplane - routes power and signals for all cage modules and power to the SURF. The harness - links the backplane to the interface panel. The interface panel - carries the T43/BIB, the required power and communications connectors.
Figure Tech. 2-6 View of CBIA cage and the interface panel
INTERFACE PANEL MAIN CAGE
HARNESS LINKS BACKPLANE CONNECTORS TO UNDERSIDE OF INTERFACE PANEL
ig.236.rh
68P02902W06-C006
Tech. 29
GSM
Backplane and harness view including door switch and heat sensors
Figure Tech. 2-7 shows the CBIA harness linking the interface panel and the backplane at rear of main cage. Each backplane harness connector is identified.
Figure Tech. 2-7 Rear view of CBIA showing backplane and harness
INTERFACE PANEL NIU to T43/BIB J21 DOOR SWITCH
T43/BIB
DOOR SWITCH CONNECTOR J55 EXTERNAL ALARMS J23 RTC J32 ICS J26 GPS J22 (if fitted) PIX J25 POWER CONNECTOR FOR SURF HARNESS SIX TRANSCEIVER CONNECTOR HOLES FOR SURF HARNESS
ig.237.rh
Tech. 210
29 Jan 2007
GSM
Figure Tech. 2-8 Front view of CBIA cage showing where modules fit
MAIN CAGE
TRANSCEIVERS (CTU/CTU2s)
2-FAN
2-FAN
4-FAN
68P02902W06-C006
Tech. 211
GSM
Routes power and digital signals throughout the cabinet. Provides connectors for the harness cables linking to the interface panel. Provides connectors for plug in modules. Provides power to the SURF harness, when the main cage is inserted into the cabinet. Provides a connector for the door switch cable. Provides connectors for three heat sensors in the main cage above the transceivers.
The required power sources. External alarms (for example battery backup system alarms). Connection points to all telecommunications links.
All connectors are linked to the backplane through the CBIA harness. Plastic connector covers, supplied by Motorola, keep unused connectors protected from damage by static or foreign matter and should be retained.
Tech. 212
29 Jan 2007
GSM
VENTILATION GRID
External alarms see Table Tech. 2-1 and accompanying information. GPS see Table Tech. 2-2. CCB see Table Tech. 2-3. BIB see Table Tech. 2-4. T43 see Table Tech. 2-5. PIX0 see Table Tech. 2-6. PIX1 see Table Tech. 2-7. ICS see Table Tech. 2-8. NOTE
Some pin connections only refer to indoor or outdoor cabinets.
68P02902W06-C006
Tech. 213
GSM
32 33 34 35 36+37
GPS connector
Table Tech. 2-2 lists the GPS connector pinouts. NOTE
The GPS connector is optional on later BTS cabinets. Table Tech. 2-2 GPS pin connections (15-way D-type) Pin No Signal/Description Pin No Signal/Description
1 2 3 4 5 6 7 8
GPS power 1 Not connected chassis earth Tx negative Tx positive Rx negative Earth GPS return 1
9 10 11 12 13 14 15
GPS power 2 Not connected PPS positive PPS negative Rx positive VPP GPS return 2
Tech. 214
29 Jan 2007
GSM
CCB connector
Table Tech. 2-3 lists the CCB connector pinouts. This provides a single connector, to provide power for up to two CCBs. NOTE
The CCB connector is not currently used on GSM850 or PCS1900 BTS variants. Table Tech. 2-3 CCB pin connections (15-way D-type) Pin No Signal/Description Pin No Signal/Description
1 2 3 4 5 6 7 8
Not connected Not connected CCB0 27 V CCB0 27 V Not connected CCB1 27 V CCB1 27 V Not connected
9 10 11 12 13 14 15
Not connected Not connected Earth Earth Not connected Earth Earth
J1
68P02902W06-C006
Tech. 215
GSM
Table Tech. 2-4 BIB interconnections NIU/ port Pin no Equipment/Ext Pin no Pin no Equipment/Ext Pin no
J0-1 J0-2 J0-4 j0-5 J0-7 J0-8 j0-10 j0-11 J0-13 J0-14 J0-16 J0-17
Tx1+ Rx1+ Tx4+ Rx4+ Tx2+ Rx2+ Tx5+ Rx5+ Tx3+ Rx3+ Tx6+ Rx6+
Tx1 Rx1 Tx4 Rx4 Tx2 Rx2 Tx5 Rx5 Tx3 Rx3 Tx6 Rx6
J1-20 J1-21 J1-23 J1-24 J1-26 J1-27 J1-29 J1-30 J1-32 J1-33 J1-35 J1-36
J1-10 J0-29 J1-11 J0-30 J1-13 J0-32 J1-14 J0-33 J1-16 J0-35 J1-17 J0-36
Connector J0 and J1 pins 3,6,9,12,15,18,19, 22, 25, 28, 31, 34 and 37 are connected to earth
Tech. 216
29 Jan 2007
GSM
Table Tech. 2-5 T43 interconnections NIU/ port Pin no Equipment / Ext Pin no Pin no Equipment / Ext Pin no
J0-1 J0-2 J0-4 j0-5 J0-7 J0-8 j0-10 j0-11 J0-13 J0-14 J0-16 J0-17
Tx1+ Rx1+ Tx4+ Rx4+ Tx2+ Rx2+ Tx5+ Rx5+ Tx3+ Rx3+ Tx6+ Rx6+
J1 centre J2 centre J4 centre J5 centre J7 centre J8 centre J10 centre J11 centre J13 centre J14 centre J16 centre J17 centre
J0-20 J0-21 J0-23 J0-24 J0-26 J0-27 J0-29 J0-30 J0-32 J0-33 J0-35 J0-36
Tx1 Rx1 Tx4 Rx4 Tx2 Rx2 Tx5 Rx5 Tx3 Rx3 Tx6 Rx6
J1 shield J2 shield J4 shield J5 shield J7 shield J8 shield J10 shield J11 shield J13 shield J14 shield J16 shield J17 shield
Connector J0 pins 3,6,9,12,15,18,19, 22, 25, 28, 31, 34 and 37 are not used
68P02902W06-C006
Tech. 217
GSM
PIX inputs
PIX inputs comprise 16 connections to external sensors. These inputs report alarms to the BSC, through the alarm board and MCUF, which forwards the alarms to the OMC-R. The end-user supplies the external sensors. Each sensor connects across an opto-coupled pair of PIX inputs (eight per PIX connector). All sensors must be dry-contact type with the following specification:
S S
5 kohms or greater across sense inputs for logic 1 (PIX opto-coupler off). 500 ohms or less across sense inputs for logic 0 (PIX opto-coupler on).
Table Tech. 2-6 shows PIX0 connections and Table Tech. 2-7 shows PIX1 connections.
Table Tech. 2-6 PIX0 pin connections (37-way D-type) Pin No Signal/Description Pin No Signal/Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Site input Ext 11 Site input Ext 21 Site input Ext 31 Site input Ext 41 Site input Ext 51 Site input Ext 61 Site input Ext 71 Site input Ext 81 Not connected Not connected Site output relay 1 NO Site output relay 2 NO Site output relay 2 NC Site output relay 3 NO Site output relay 4 NO Site output relay 4 NC Not connected Not connected
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36/37
Not connected Site input Ext 12 Site input Ext 22 Site input Ext 32 Site input Ext 42 Site input Ext 52 Site input Ext 62 Site input Ext 72 Site input Ext 82 spare Site output relay 1 NC Site output relay 1 COM Site output relay 2 COM Site output relay 3 NC Site output relay 3 COM Site output relay 4 COM Not connected Not connected
Tech. 218
29 Jan 2007
GSM
Table Tech. 2-7 PIX1 pin connections (37-way D-type) Pin No Signal/Description Pin No Signal/Description
1 2 3 4 5 6 7 8 9
Site input Ext 91 Site input Ext 101 Site input Ext 111 Site input Ext 121 Site input Ext 131 Site input Ext 141 Site input Ext 151 Site input Ext 161 Not connected Pins 10 to 18 not connected
19 20 21 22 23 24 25 26 27
Not connected Site input Ext 92 Site input Ext 102 Site input Ext 112 Site input Ext 122 Site input Ext 132 Site input Ext 142 Site input Ext 152 Site input Ext 162 Pins 28 to 37 not connected
ICS connector
Table Tech. 2-8 lists the Integrated Cell Site (ICS) connector pinouts. This is a future feature.
Table Tech. 2-8 ICS pin connections (25-way D-type) Pin No Signal/Description Pin No Signal/Description
1 2 3 4 5 6 7 8 9
ICS0 TTY earth ICS0 TTY Rx ICS0 TTY Tx ICS1 TTY earth ICS1 TTY Rx ICS1 TTY Tx ICS2 TTY earth ICS2 TTY Rx ICS2 TTY Tx
10 11 12 13 14 15 16 17 18
ICS3 TTY earth ICS3 TTY Rx ICS3 TTY Tx ICS4 TTY earth ICS4 TTY Rx ICS4 TTY Tx ICS5 TTY earth ICS5 TTY Rx ICS5 TTY Tx
68P02902W06-C006
Tech. 219
GSM
Protects modules from damage. Ensures correct air ventilation. Provides EMC shielding.
The door has a ventilation grid with internal honeycomb grid, a vertical aluminium air baffle, and a horizontal door stop bracket. The door stop bracket enables the door to open to 95 or 130 degrees. The lock is a trigger latch, opened (if unlocked) by pressing the middle button. There is also a door alarm bracket, to touch the cabinet door switch.
EXTERNAL VIEW
HONEYCOMB VENTILATION
VENTILATION GRID
TRIGGER LATCH
ig.266.rh
Tech. 220
29 Jan 2007
GSM
Hood function
The optional hood can be fitted to keep unsightly cables and connectors out of view, where this is important.
View of hood
Figure Tech. 2-13 shows a top view of the hood.
Figure Tech. 2-13 View of hood as seen from the front of the cabinet
LIFTING EDGE
ig.267.rh
68P02902W06-C006
Tech. 221
GSM
To enable a second cabinet to be stacked on top of the first cabinet. To house CCBs in a dedicated optional CCB basket.
The stacking bracket is fixed to the top of the cabinet by eight M8 screws. If the stacking bracket is replacing an existing hood, then the four hood securing pins must first be removed to accommodate four of the stacking bracket screws. A second cabinet may be attached on top of the stacking bracket by four M10 screws. Lower cabinet outlet and additional upper cabinet inlet ventilation is provided by the large open sides of the stacking bracket (especially on the right side of the cabinet). The CCB basket is fitted only if CCBs are required. The CCB basket is removable, to enable access for SURF module replacement.
Figure Tech. 2-14 View of stacking bracket with CCB basket installed.
M10 HOLES (4) FOR TOP CABINET ATTACHMENT (IF REQUIRED) REAR OF BRACKET
Tech. 222
29 Jan 2007
GSM
Protection for CCB (if fitted). Blanking panel to match appearance of cabinet door.
Figure Tech. 2-15 View of two stacked Horizonmacro indoor cabinets showing stacking bracket front covers
Inlet air
Inlet air
68P02902W06-C006
Tech. 223
GSM
Tech. 224
29 Jan 2007
Chapter 3
68P02902W06-C006
Tech. 31
GSM
Tech. 32
29 Jan 2007
GSM
Temperature sensors
The three cabinet temperature sensors are located above the transceiver compartment (see Figure Tech. 2-7) and consist of the following:
S
One 70 _C sensor provides a cabinet overtemperature alarm when the cabinet temperature exceeds planned level. The alarm is processed by the alarm board and MCUF, and sent on to the OMC-R through the BSC. Two 85 _C sensors shut down the PSMs to protect the cabinet equipment from heat damage. Both sensors must detect excess temperature for the shutdown to take place; this reduces the risk of an unnecessary shutdown. No prior notification of shutdown is given to the OMC-R, except for the original 70 _C sensor alarm. This is because the MCUF and transceivers immediately lose power and functionality.
68P02902W06-C006
Tech. 33
GSM
One 4-fan unit (referred to as FAN0), located in front and beneath the digital module shelf. Two identical 2-fan units (FAN1 and FAN2), located beneath the transceivers.
Figure Tech. 3-1 shows the two types of fan unit: Figure Tech. 3-1 View of 2-fan and 4-fan units
2-FAN UNIT
4-FAN UNIT
RESET BUTTONS (ONE PER FAN) SLIDE LATCH FOR MODULE REMOVAL
Tech. 34
29 Jan 2007
Chapter 4
68P02902W06-C006
Tech. 41
GSM
Tech. 42
29 Jan 2007
GSM
The power supply modules (PSM): +27 V dc PSM (negative earth input). 48/60 V dc PSM (positive earth input). 120/240 V ac (nominal) PSM.
S S S
The hold-up battery module. The circuit breaker module (CBM). The mBCU power supply module (BPSM).
BPSMs
68P02902W06-C006
Tech. 43
GSM
Nominal +27 V (negative earth input). Nominal 48 V (positive earth input). Nominal 120/240 V. NOTE
CTU2 transceivers cannot be used in cabinets powered from 120 V ac.
All PSMs have the same external appearance and are located in the same positions. Different types are identified only by front panel labels. The PSMs are fed from a backplane connector and use pulse width modulation to generate output supply. A front panel switch (shown in Figure Tech. 4-2), disables the output, reducing the input current as shown in Table Tech. 4-1.
Table Tech. 4-1 Input currents for power supply module Type of PSM Output voltage full load Input current full load Input load when output switch off
32 A 18 A 3.75 A
1A 0.5 A 0.1 A
NOTE
There are several manufacturers of the PSMs. Each is fully compatible with the same type of PSM of a different manufacturer.
Tech. 44
29 Jan 2007
GSM
1 2 3
When a combination of CTUs and CTU2s or CTU2s only are installed, all three slots may be required for PSMs and in such cases redundancy cannot be provided. Table Tech. 4-3 shows the PSM configuration requirements for different CTU/CTU2 combinations.
Table Tech. 4-3 PSM operational configurations, CTU/CTU2 combinations No. of PSMs installed 1 2 3 CTU/CTU2 combinations supported 1/1, 0/1 4/1, 3/1, 2/1, 3/2, 2/2, 1/2, 0/2, 1/3, 0/3, 0/4 5/1, 4/2, 3/3, 2/3, 2/4, 1/4, 1/5, 0/5, 0/6
68P02902W06-C006
Tech. 45
GSM
PSM alarms
There are three alarms for each PSM, indicated by LEDs (see Table Tech. 4-4):
S S S
PSM LEDs
The LEDs function with the properties shown in Table Tech. 4-4.
Table Tech. 4-4 Power supply module LEDs function Green LED ACTIVE Red LED ALARM Indication
OFF ON OFF
OFF OFF ON
1. Cabinet power supply off, or 2. Module not connected. Normal operation. 1. Output disable switch off, or 2. Alarm condition with module unable to supply power. Internal problem (such as over temperature), but still able to maintain supply.
ON
ON
Tech. 46
29 Jan 2007
GSM
Under normal operating conditions the hold-up batteries provide ten seconds of backup power (at 25 _C) for a fully populated (six CTU) Horizonmacro indoor BTS cabinet. NOTE
Due to the discharge characteristics of the internal batteries, hold-up duration is reduced at temperatures below 25 _C.
Figure Tech. 4-3 shows a view of the hold-up battery module, with LEDs identified. Figure Tech. 4-3 View of the hold-up battery module
68P02902W06-C006
Tech. 47
GSM
Specifications
Table Tech. 4-5 shows the hold-up battery module specifications.
Table Tech. 4-5 Hold-up battery module specifications Weight Environmental limits Nominal input voltage and frequency Supply voltage and frequency range Nominal output voltage Output voltage range
5.9 kg 5 to +45 _C (indoor only) 100 to 240 V ac 50 to 60 Hz 88 to 270 V ac 45 to 66 Hz 24 V dc 27.5 0.25 V dc (max) 19 0.25 V dc (min) 1500 watts 5 Ah < 2 hours (from LVD level) < 10 msec 88 volts (110 V ac nominal systems) 150 volts (230 V ac nominal systems) 10 seconds (@ 25 _C) 3 to 5 y years 1200 cycles
Maximum output power Battery capacity Recharge time Response time (from external supply failure to battery operation) Back up switching voltage Typical output power duration * (six CTUs) Expected battery life (standby) Expected battery life (discharge)
* The duration is reduced when CTU2s are installed in the cabinet. NOTE
This specification is valid up to 3 km altitude, corresponding to an atmospheric pressure of approximately 70 kPa (648 to 1048 millibars).
Tech. 48
29 Jan 2007
GSM
ACTIVE (green). Normally lit, this LED indicates that the module is capable of powering cabinets. The ACTIVE LED flashes during discharge.
ALARM (red). Normally unlit, when lit continuously this LED indicates one or more of the following alarm conditions exists: Battery charger fail. Input voltage drops below 88 V ac (110 V systems) or below 150 V ac (230 V systems). Enable fail, the module is not receiving an enable signal from the Horizonmacro backplane.
When the ALARM LED is flashing the batteries have failed and are not capable of providing sufficient energy to supply a ten second hold-up. NOTE
If a battery failure occurs, the batteries may have reached the end of life. The hold-up battery module is disabled and must be returned to Motorola for repair.
CHARGE (green). The CHARGE LED is lit while batteries are charging.
68P02902W06-C006
Tech. 49
GSM
Functional description
During normal operation the batteries are charged by an internal battery charger. The charger provides battery temperature compensation to protect the batteries. In the case of external ac power supply failure, the unit automatically switches the BTS to battery operation. The hold-up battery module indicates failure alarms to the OMC-R, through the Horizonmacro alarm board.
Enable
Transistor switch
LVD
Input detect
Fuse
Tech. 410
29 Jan 2007
GSM
Alarms
Alarms are generated by the open contacts of de-energized relays within the hold-up battery module, (during normal operation the relays are energized and the contacts closed). The contacts are rated for 1 A at 30 V. The alarms are then passed to the Horizonmacro alarm board, through the CBIA backplane, for onward transmission to the OMC-R. These alarms are equivalent to the PSM alarms. The alarm signals generated are:
S
Output fail. This alarm is triggered if: The enable pin is not correctly plugged into the backplane. The battery charger fails. The front panel enable switch is off. The batteries fail.
If a battery failure occurs, the batteries may have reached the end of life. The hold-up battery module is disabled and must be returned to Motorola for repair.
NOTE
Input fail. This alarm is triggered if the external ac supply voltage drops below: 88 volts (110 V ac nominal systems). 150 volts (230 V ac nominal systems).
Over temperature. This alarm is triggered if the hold-up battery module temperature exceeds 50 _C.
Signals
The following signals interface with the Horizonmacro backplane:
S
Enable. The output of the hold-up battery module is inhibited unless the ENABLE signal pin is connected to the output return pin through the Horizonmacro backplane.
Hold-up module ID. The hold-up module provides a five bit TTL signal to the OMC-R that allows identification of the hold-up module. This signal is available when ac is present and during battery discharge and identifies to the OMC-R the that a battery hold-up module is fitted.
68P02902W06-C006
Tech. 411
GSM
View of CBM
Figure Tech. 4-5 shows views of the CBM with circuit breaker buttons identified.
Figure Tech. 4-5 Views of CBM with circuit breaker buttons identified
BACKPLANE CONNECTOR HANDLE-BAFFLE
CCB (0 AND 1) 4A
SURF FANS 2A 7A
BPSMs (A AND B) 7A
6 TRANSCEIVERS (0 TO 5) 12 A
FRONT VIEW
Tech. 412
29 Jan 2007
GSM
Operation of CBM
Power for each module is supplied through the appropriate circuit breaker switch. Overload of any circuit results in appropriate front panel circuit breaker button tripping to the off (out) position. The button can be pressed to the on (in) position when overload problem has been corrected. Transceivers, BPSMs, CCBs, SURF and fans can be isolated by pressing and releasing the appropriate button to the off (out) position. Power is restored by pushing the appropriate button to the on (in) position.
68P02902W06-C006
Tech. 413
GSM
An optional second BPSM can be fitted in the upper half of the digital module shelf to supply any or all of the following:
S S S
Backup power to the alarm module, which is the only digital module supplied by both BPSMs (for redundancy). Optional redundant MCUF and associated FMUX. Up to two additional NIUs.
During normal operation, with all the outputs within their regulation limits, a green LED located on the front panel is illuminated. No alarms are generated by the BPSM.
BPSM diagram
Figure Tech. 4-6 shows a BPSM. Figure Tech. 4-6 BPSM view
BACKPLANE CONNECTOR
GREEN LED
ig.274.rh
Tech. 414
29 Jan 2007
GSM
Functional description
The BPSM is a switching type dc/dc power converter that converts the cabinet +27 V dc power to the following regulated dc outputs:
S S S S
+3.3 V 1 % at 10 A (full load current) +5 V 2 % at 10 A (full load current). +12 V 5 % at 4 A (full load current). 12 V 5 % at 2 A (full load current).
Internal BPSM circuits monitor the +3.3 V, +5 V, +12 V and 12 V outputs for the following purposes:
S S S
Output voltage regulation. Over-voltage protection - provides shutdown if output voltage exceeds 1.1 to 1.2 times the rated output. Over-current protection - maximum output current has the following limits: 1.1 to 1.8 times full load rating of +3.3 V output. 1.1 to 1.8 times full load rating of +5 V output. 1.25 to 2 times full load rating of +12 V and 12 V outputs.
Circuit protection
Additional internal circuitry protects the BPSM:
S S S
Input dc reverse polarity protection, achieved by an input series diode. Thermal protection by automatic BPSM shutdown. Normal BPSM operation resumes after BPSM temperature returns to a safe level. A 10 Amp fuse is located near the backplane connector.
LED display
An active (Green) LED mounted on the front of the BPSM is on when all output voltages are present and within specified limits. A functional diagram is shown in Figure Tech. 4-7. Figure Tech. 4-7 Functional diagram of BPSM
BACKPLANE CONNECTOR VOUT (+5 V) VOUT (+12 V) Green LED Power converter and system monitor VIN (+27 V) VOUT (12 V) VOUT (+3.3 V)
ig.275.rh
68P02902W06-C006
Tech. 415
GSM
Tech. 416
29 Jan 2007
Chapter 5
RF modules
68P02902W06-C006
Tech. 51
GSM
Tech. 52
29 Jan 2007
GSM
RF equipment detail
RF equipment detail
Overview of RF equipment
This chapter describes the functional operation of radio frequency (RF) modules used in the cabinet. All descriptions are presented at a block diagram level.
RF modules described
The following equipment is described:
S S S S
Compact Transceiver Unit (CTU). Compact Transceiver Unit 2 (CTU2). Sectorized Universal Receiver Front-end SURF module (for receive path), both single and dual band variants. Several types of transmit block (Tx block). Tx blocks are used for various configurations of transmit path, depending on number of antennas, CTUs and functionality, including potential shared receive path. Cavity combining block CCB, used to combine three CTU transmit paths in conditions where Synthesizer Frequency Hopping (SFH) is not required. Two CCBs can combine up to six CTU transmit paths on to a single Tx antenna.
General definition of transmit and receive functions in this section. An RF overview and RF test function description in the next section. An explanation of Frequency hopping in a section immediately after the CTU section.
These descriptions are intended to assist the reader in understanding the information on the RF modules.
RF specifications
All equipment meets or exceeds ETSI regulations. Frequency information is listed in the Specifications part of this manual.
68P02902W06-C006
Tech. 53
RF equipment detail
GSM
Receive RF hardware
Receiver RF hardware consists of the SURF module and optional Tx block receive path, and the receive section of the transceiver. The SURF module provides bandpass filtering and low-noise amplification for up to three sectors, with diversity receive antenna signals, together with switching to the transceivers.
Transceiver Rx role
The transceiver (CTU or CTU2) provides the following receive functions:
S S S S S S S
Receiver tuning (on a timeslot basis) to any receive channel frequency. Demodulation and equalization of the receive channel signal. Measurement of the received signal strength indication (RSSI) and signal quality. Recovery of received data from the demodulated radio channel. Channel decoding of the received data and processing of the recovered signal. Traffic data is passed on to the MCUF for routeing to the MSC. Digital interface to the SURF module, which controls selection by the SURF switch of the receive signals from the appropriate antenna. Comparison and processing of an additional receive path from a second diversity antenna input to compensate for multipath fading and interference.
Tech. 54
29 Jan 2007
GSM
RF equipment detail
Transceiver Tx role
The transceiver (CTU or CTU2) provides the following transmit functions:
S S S S S S
Transmit tuning (on a timeslot basis) for generation of any transmit channel RF frequency. Encoding transmit data output. Digital modulation of transmit data onto the transmit radio channel signal. Final RF power amplification and output power level control of the transmit radio channel RF signal. When using a CCB, the output of control data to the CCB (CTU only). Channel encoding of the data to be transmitted, interleaving signal and traffic channel data, as defined by ETSI.
68P02902W06-C006
Tech. 55
GSM
The transceiver (CTU or CTU2). The SURF module. The Tx block or alternatively CCBs.
CTU
The CTU can operate at 850 MHz, 900 MHz, 1800 MHz or 1900 MHz, depending on the BTS variant ordered. It can receive two inputs, RxA and RxB, from the SURF. These inputs are converted into digital voice/data. The two Rx signals provide diversity of the Rx function from the MS (uplink). The CTU also generates a Tx data signal, translated from received digital voice/data, which is transmitted by cable to the Tx block for antenna transmission to the MS (downlink). The third (middle) port provides an RF loopback test signal capability, for automatic transmission of RF test signals to the SURF.
CTU2
The CTU2 operates in a similar manner to the CTU but has the following differences:
S S
Does not support operation at 850 MHz or 1900 MHz. Does not have a separate loopback test port (L). Port RxC is used instead.
Separate detailed descriptions of the CTU and CTU2 are provided later in this chapter.
Tech. 56
29 Jan 2007
GSM
SURF module
One of six variants of the SURF module can be installed in the Horizonmacro indoor:
S S S S S S
Single band 850 MHz SURF. Single band 900 MHz SURF. Dual band 900 MHz SURF. Single band 1800 MHz SURF Dual band 1800 MHz SURF. Single band 1900 MHz SURF.
The single band SURF modules accept up to three pairs of antenna inputs, and the dual band SURF modules accept up to four pairs of antenna inputs. The SURF switches the inputs to the appropriate transceivers under the control of the database through the MCUF. There are two inputs to each transceiver for Rx diversity. The SURF also contains loopback test circuitry, connecting with a test signal from each transceiver.
Tx block
There are up to three Tx blocks, each block serving two transceivers. Tx blocks filter the transmit signal for the required Tx band. Tx blocks also use filters to enable the Rx frequency signal to be passed to the SURF, if one antenna is used for both Tx and Rx signals.
CCBs
Cavity combining blocks (CCBs) are an alternative to Tx blocks. CCBs combine up to three CTU transmit paths. Two CCBs can combine up to six CTU transmit paths. CCBs have no duplexing capability and must be connected to an antenna through an external high power duplexer (HPD). CCBs cannot be used with the GSM850 or PCS1900 BTS variants, or when SFH (see Frequency hopping) is required. NOTE
CCBs cannot be used with CTU2 transceivers.
68P02902W06-C006
Tech. 57
GSM
RF loopback
Purpose
The loopback test function is primarily used to identify faults when the RF system has failed. The loopback test function enables a diagnostic capability at the OMC-R, by creating a test signal to identify if the fault is either:
S S
Software (that the OMC-R can correct). Particular hardware (transceiver or SURF).
The result is a reduction in site assessment visits, and avoidance of unnecessary visits when hardware is functioning correctly. NOTE
The RF loopback test feature available on the Horizonmacro is not available on previous generations of equipment.
Hardware
The RF loopback test function is essentially a hardware capability built into the transceiver and the SURF. Software instructions activate the test hardware, to route test signals through the RF system.
Software operation
When installed with suitable software, GSR5 or later, the OMC-R can operate the loopback test functions, and receive the results of the tests.
Tech. 58
29 Jan 2007
GSM
RF functional diagram
Figure Tech. 5-1 shows the basic RF and loopback/VSWR test functions. For clarity, only one CTU (and one CTU2), one Tx block, and part of the SURF are shown. CCBs could be used instead of Tx blocks with CTUs (but not CTU2s). Figure Tech. 5-1 RF functional diagram
B A A B SURF B
RxA
RxB
RxA CTU2
RxB
RxC
of CTU2 Tx
68P02902W06-C006
Tech. 59
GSM
The loopback test hardware picks up an attenuated signal by coupled link from the normal transceiver transmit signal. The signal is mixed down to the receive band for testing the Rx functionality of the SURF and transceiver. Power to the loopback circuitry is automatically turned off when the radio is in normal operation.
Tech. 510
29 Jan 2007
GSM
The CTU:
S S
Generates the RF frequencies required to perform the transmit and receive functions. Contains the digital circuits required for eight timeslots of channel equalization, encoding and decoding, and transceiver control logic.
The CTU provides the air interface between a BSS and MSs, with the following features:
S S S
Capability of diversity reception (input from two antennas) which improves the quality reception in the presence of multipath fading and interference. Frequency change on a timeslot basis for frequency hopping and equipment sharing. Transmit power control.
CTU transceiver (XCVR) board. Power amplifier (PA) board. Power supply unit.
68P02902W06-C006
Tech. 511
GSM
Alarm reporting
The CTU status is displayed by LED indicators on the front panel, as shown in Figure Tech. 5-2, and detailed in Table Tech. 5-1. Major sub-systems, such as synthesizers and RF amplifiers, are monitored, with alarm signals as necessary.
Table Tech. 5-1 CTU front panel status indicators Indicator LED When the LED is Then CTU
RADIO STATUS
Module off Code required or being loaded Normal operational mode Test mode Radio inhibited Alarm condition Transmitter is off Transmitter is keyed on Non-volatile memory boot code upgrade (Do not remove power or reset see CAUTION)
CAUTION
When both LEDs are flashing, the boot code is downloading into non-volatile memory for software upgrade. Power should not be removed, nor the cabinet reset, until downloading has been completed, as this will corrupt the non-volatile memory. If the boot code is corrupted, contact Motorola Customer Network Resolution Centre requesting the boot code restoration procedure and the appropriate boot code file.
Tech. 512
29 Jan 2007
GSM
View of a CTU
Figure Tech. 5-2 shows the CTU with main features identified.
Tx OUT CONNECTOR
TEST INTERFACE
HANDLE
RADIO STATUS LED RECESSED MANUAL RESET BUTTON (if fitted) Tx STATUS LED
68P02902W06-C006
Tech. 513
GSM
Radio subsystem (RSS). Equalizer and control processor (EQCP). Channel coder control processor (CCCP).
A test interface port on the CTU front panel provides access to critical test points for factory alignment and maintenance. Pressing the reset push button generates a hard reset of the processor, initiating a normal power-up. Later versions of the CTU (mid 2001 onward) have no reset button, reset is acheived by operation of the appproriate CTU circuit breaker on the CBM. Figure Tech. 5-3 shows the front panel and Table Tech. 5-2 lists connector functions. Figure Tech. 5-3 CTU front panel
Tx OUT CONNECTOR
TEST INTERFACE
TTY INTERFACE . RADIO STATUS LED RECESSED MANUAL RESET BUTTON (if fitted) Tx STATUS LED
Table Tech. 5-2 CTU front panel connectors Front panel legend Function Connection to
Tech. 514
29 Jan 2007
GSM
CTU Tx connector
The CTU Tx connector is a short SMA to SMA link to the base of the appropriate Tx block or feedthrough plate. NOTE
The Tx cable has a 90 SMA connector at one end and a straight SMA connector at the other end. The 90 end is designed for connection to the Tx port of a CTU.
CTU Rx function
The receiver part of the CTU accepts two amplified and filtered receive antenna signals from the SURF module. These two signals are applied to inputs (branch A and branch B) of the CTU transceiver board. The input from the SURF module is filtered, amplified and down converted to ensure the signal level and frequency range are correct for the next stage.
Master GSM air interface timing function. Independent Rx gain control interface for each diversity receiver branch. Baseband Rx data interface for each diversity receiver branch. Receiver front end and CCB control. Tx data interface including GMSK modulator which provides baseband data to the transmitter. Tx and power amplifier power control interface. Rx and Tx frequency synthesizer control which supports RF frequency hopping. CTU and cabinet alarm data collection. Alarms sampling and multiplexing.
68P02902W06-C006
Tech. 515
GSM
CTU2s cannot be used in Horizonmacro outdoor BTSs. CTU2s cannot be used in Horizonmacro indoor BTSs that are powered from 110 V ac. BBH is only supported in single density mode when CTU2s are used in Horizonmacro indoor BTSs. CCBs are not supported when CTU2s are used in Horizonmacro indoor BTSs. RF output power from the CTU2s is reduced (see Specifications in Chapter 1). PSU requirements may change, depending on the number of CTU2s installed (see Table Tech. 4-3 in Chapter 4).
The CTU2:
S
Generates the RF frequencies required to perform the transmit and receive functions. Contains the digital circuits required for 32 timeslots of channel equalization, encoding and decoding, and transceiver control logic.
The CTU2 provides the air interface between a BSS and MSs, with the following features:
S
Capability of diversity reception (input from up to four antennas) which improves the quality reception in the presence of multipath fading and interference. Frequency change on a timeslot basis for frequency hopping and equipment sharing. Transmit power control.
Technical Description: Horizonmacro indoor 68P02902W06-C006
Tech. 516
29 Jan 2007
GSM
CTU2 features
The CTU2 has the following features:
S
Single or double density mode in the Horizonmacro indoor cabinet. Single density mode provides single carrier GSM Tx capability. Double density mode provides 2 carrier GSM Tx capability (both carriers must be in the same sector). Single carrier EGPRS Tx capability. Backwards compatible with the CTU (but BBH restrictions apply if used in double density mode). Transmit diversity. Two branch Rx diversity. Hardware support for AMR (upgrade required for pre-GSR7 software).
S S S S S
CTU2 transceiver (XCVR) board. Power amplifier (PA) board. Power supply unit.
68P02902W06-C006
Tech. 517
GSM
Alarm reporting
The CTU2 status is displayed by LED indicators on the front panel, as shown in Figure Tech. 5-4, and detailed in Table Tech. 5-3. Major sub-systems, such as synthesizers and RF amplifiers, are monitored with alarm signals as necessary.
Table Tech. 5-3 CTU2 front panel status indicators LED Status Meaning
RADIO STATUS
CTU2 is off. Boot code being loaded. (Do not remove power or reset see CAUTION below.) Normal operational mode. Test mode. Transceiver inhibited. Alarm condition. Flash reprogramming in progress. (Do not remove power or reset see CAUTION below.) Transmitter A is off. Transmitter A is keyed on. Transmitter B is off. Transmitter B is keyed on.
Green Flashing yellow Yellow Red Alternately flashing red and green TRANSMIT (Tx) (T ) STATUS A TRANSMIT (Tx) (T ) STATUS B Unlit Yellow Unlit Yellow
CAUTION
Removing power or resetting the cabinet while the boot code is downloading or flash reprogramming is taking place will cause memory corruption. If the boot code is corrupted, contact Motorola Customer Network Resolution Centre requesting the boot code restoration procedure and the appropriate boot code file.
Tech. 518
29 Jan 2007
GSM
View of a CTU2
Figure Tech. 5-4 shows the CTU2 with main features identified.
Tx OUT CONNECTOR
Rx D Rx A Rx C Rx B
NOTE
68P02902W06-C006
Tech. 519
GSM
Radio subsystem (RSS). Equalizer and control processor (EQCP). Channel coder control processor (CCCP).
A test interface port on the CTU2 front panel provides access to critical test points for factory calibration and maintenance. Figure Tech. 5-5 shows the front panel and Table Tech. 5-4 lists connector functions. Figure Tech. 5-5 CTU2 front panel
Tx OUT CONNECTOR
TEST INTERFACE
TTY INTERFACE . VCAT INTERFACE RADIO STATUS LED NOTE The CTU2 does not have a reset button. A reset is acheived using the appproriate CTU2 circuit breaker on the CBM. Tx STATUS A LED Tx STATUS B LED
Table Tech. 5-4 CTU2 front panel connectors Front panel legend Function Connection to
Tech. 520
29 Jan 2007
GSM
CTU2 Tx connector
The CTU2 Tx connector is a short SMA to SMA link to the base of the appropriate Tx block or feedthrough plate. NOTE
The Tx cable has a 90 SMA connector at one end and a straight SMA connector at the other end. The 90 end is designed for connection to the Tx port of the CTU2.
CTU2 Rx function
The receiver part of the CTU2 can accept two amplified and filtered receive antenna signals from the SURF module. These two signals are applied to inputs (branch A and branch B) of the CTU2 transceiver board. The transceiver can be configured to provide double density receive capacity or 4 branch Rx diversity, although only 2 branch Rx diversity is possible when used in the Horizonmacro indoor. In double density mode, the receiver provides demodulation of a main and diversity path for two RF channels. The input from the SURF module is filtered, amplified and down converted to ensure the signal level and frequency range are correct for the next stage.
2B
1B
0B
2A
1A
0A EXT EXT B A
SURF CTU2
Rx D Rx A Rx C Rx B Branch 1 (main) LPBK / VSWR Branch 2 (diversity) B C A
NOTE
Rx A on the CTU2 carries the SURF control and alarm signals. The 7-pin connectors A and C on the base of the SURF carry 6 x RF signals + 1 earth and connector B carries 6 x RF signals + 1 power.
The physical interface between the SURF and the CTU2 consists of three connections, one bi-directional and two directional. The bi-directional connection is for the RF receive main branch (branch 1) and for digital communication between the SURF and the CTU2. One directional connection is for the RF receive diversity branch (branch 2), and the other is for the loopback or VSWR mode selection and the LPBK / VSWR signal.
Technical Description: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Tech. 521
GSM
Master GSM air interface timing function. Independent Rx gain control interface for each diversity receiver branch. Baseband Rx data interface for each diversity receiver branch. Receiver front end control. Tx data interface including GMSK modulator which provides baseband data to the transmitter. Tx and power amplifier power control interface. Rx and Tx frequency synthesizer control which supports RF frequency hopping. CTU2 and cabinet alarm data collection. Alarms sampling and multiplexing.
Tech. 522
29 Jan 2007
GSM
EGPRS capability
The CTU2 is EGPRS-capable, enabling data rates up to 384 kbit/s. From a hardware perspective the main difference between GSM/GPRS and EGPRS is the use of 8PSK (8 Phase Shift Keying) modulation instead of GMSK (Gaussian Minimum Shift Keying). GPRS and EGPRS use the same symbol rate, however the modulation bit rates are different. In GSM/GPRS, each transmitted symbol (phase change) represents one bit, wheras with 8PSK modulation three consecutive bits are related to a symbol. A basic technical comparison between GPRS and EGPRS is shown in Table Tech. 5-5.
Table Tech. 5-5 Comparison between GPRS and EGPRS GPRS Modulation Symbol rate Modulation bit rate Radio data rate per time slot User data rate per timeslot User data rate (8 time slots) EGPRS
GMSK 270 ksyms 270 kbit/s 22.8 kbit/s 20 kbit/s 160 kbit/s
8PSK 270 ksyms 810 kbit/s 69.2 kbit/s 59.2 kbit/s 473.6 kbit/s
NOTE
Although theoretical bit rates of 473.6 kbit/s can be achieved, it is limited to the ITU-defined bit rate of 384 kbit/s, corresponding to 48 kbit/s per timeslot.
68P02902W06-C006
Tech. 523
Frequency hopping
GSM
Frequency hopping
Overview of transceiver frequency hopping
The CTU and CTU2 transceivers support two types of frequency hopping, synthesizer frequency hopping (SFH) and baseband frequency hopping (BBH). This section provides an explanation of both types. In either type, the MS switches channels after every transmit/receive (Tx/Rx) burst pair. The difference between SFH and BBH is in the method by which channel switching is achieved at the BTS. NOTE
BBH is not possible if the CTU2 is used in double density mode in a Horizonmacro cabinet which is controlled by a MCUF site controller (refer to System Information: BSS Equipment Planning 68P02900W21 for further details).
Tech. 524
29 Jan 2007
GSM
SURF module
SURF module
SURF module overview
The sectorized universal receiver front end (SURF) module is located in a slot at the rear of the cabinet top panel. Three connectors on the underside of the module connect to the SURF harness which provides connectivity to up to six transceivers. Antenna connections are located on the top of the unit. There are six types of SURF module available for the Horizonmacro indoor BTS, depending on the frequency variant:
S S S S S S
850 (MHz) single band SURF. 900 (MHz) single band SURF. 900 (MHz) dual band SURF. 1800 (MHz) single band SURF. 1800 (MHz) dual band SURF. 1900 (MHz) single band SURF.
The single band SURFs contains three amplifier sections for connection to three pairs of receive antenna inputs providing reception at the appropriate frequency. The 900 dual band SURF contains three amplifier sections for connection to three pairs of antennas providing 900 MHz reception and, being dual band, a further amplifier section for connection to a pair of 1800 MHz receive antennas. The 1800 dual band SURF similarly contains three amplifier sections for connection to three pairs of antennas providing 1800 MHz reception and a further amplifier section for connection to a pair of 900 MHz receive antennas. Each amplifier section provides two receive outputs which may be directed to any of the six transceivers, by the switch section. There are three connections to each transceiver; RxA, RxB and loopback test (L). The two receive outputs from amplifier 0 are split and may be used as extensions to other cabinets if required. These act as extended antenna connections from antenna 0. The extension cables are connected to the receive antenna connection ports on the SURF of the extension cabinet (which is able to respond to each amplified signal as if it were a normal antenna input). NOTE
The 900 MHz and 1800 MHz single and dual band SURFs may vary slightly in appearance, depending on when the BTS was manufactured. Later single band SURFs have blanked out holes in the positions where the second frequency N-type connectors would be fitted in dual band variants (see Figure Tech. 5-7). Later dual band SURFs have slightly different label numbering for the second frequency connectors. These were originally numbered 0A and 0B, but are now numbered 1A and 1B respectively. This later numbering convention is used throughout the remainder of this manual.
68P02902W06-C006
Tech. 525
SURF module
GSM
Figure Tech. 5-7 Single band SURF module (later type) with features identified
SIX N-TYPE RECEIVE ANTENNA CONNECTIONS (2 PER DLNB EQUIVALENT)
RX-Pn RX-Pn 2B 0B RX-Pn 1B RX-Pn 2A RX-Pn 1A RX-Pn 0A EXTENSION PORTS TO OTHER CABINETS M6 MODULE ATTACHMENT SCREWS HANDLE FOR MODULE REMOVAL
SURF MODULE
NOTE
Where RX-Pn appears in Figure Tech. 5-7, the n may be 850, 900, 1800 or 1900, depending on the frequency of the SURF module.
Tech. 526
29 Jan 2007
GSM
SURF module
Figure Tech. 5-8 Single band SURF module (earlier type) with features identified
SIX N-TYPE RECEIVE ANTENNA CONNECTIONS (2 PER DLNB EQUIVALENT) RXn 2B RXn 1B RXn 0B RXn 2A RXn 1A RXn 0A
SURF MODULE
GUIDE RAIL FOR INSERTION
68P02902W06-C006
Tech. 527
SURF module
GSM
Tech. 528
29 Jan 2007
GSM
SURF module
Figure Tech. 5-9 Functional diagram of the single band SURF module
68P02902W06-C006
Tech. 529
SURF module
GSM
Figure Tech. 5-10 Later type dual band SURF module with features identified
EIGHT N-TYPE RECEIVE ANTENNA CONNECTIONS (2 PER DLNB EQUIVALENT) SECOND FREQUENCY RX-S 1B
NOTE
Second frequency labelling on earlier types of dual band SURF differs slightly from that shown in Figure Tech. 5-10. 1A and 1B are labelled 0A and 0B on earlier SURFs.
Tech. 530
29 Jan 2007
GSM
SURF module
68P02902W06-C006
Tech. 531
SURF module
GSM
Figure Tech. 5-11 Functional diagram of the dual band SURF module
Tech. 532
29 Jan 2007
GSM
Tx blocks overview
Tx blocks overview
Introduction to transmit blocks
Transmit (Tx) blocks are located in three positions in the basket above the transceivers. There are four types of transmit (Tx) blocks, three of which are available as 850, 900, 1800 or 1900 variants, and one dual band variant (for use with 900 MHz or 1800 MHz BTSs only). CAUTION
S S S S Unused Tx block locations must be covered with a blanking plate for correct air flow and EMC shielding.
TDF (850, 900, 1800 or 1900) Twin duplexed filter. Dual band TDF (900/1800) Dual band twin duplexed filter. DCF (850, 900, 1800 or 1900) Duplexed combining bandpass filter. DDF (850, 900, 1800 or 1900) Dual-stage duplexed combining filter.
These Tx blocks are cooled by airflow underneath. The DDF has fins, whereas the TDF, dual band TDF and DCF do not. Three types of plate can be located in the basket, one as blanking plate and two to interface transceiver Tx cables:
S S S
Blanking plate. This ensures proper air flow and EMI shielding for an unused basket Tx block location. Feedthrough plate. This converts two SMA connectors to two N-type connectors, used for connecting Tx cables to CCBs or DDFs. Hybrid combining unit (HCU). This combines two SMA connectors to one N-type, enabling two additional transceivers to be connected to a DDF.
One type of Tx unit is installed in the stacking bracket, and is connected to three CTUs: CCB Cavity Combining Block. Two CCBs are required for the six CTUs of a filled cabinet. The CCB has no duplexing capability and, if a single Rx/Tx antenna is used, connection must be through an external high power duplexer. NOTE
CCBs are not currently available for use with the 850 MHz or 1900 MHz BTS variants. CCBs cannot be used with CTU2 transceivers.
68P02902W06-C006
Tech. 533
Tx blocks overview
GSM
SMA connectors for cables to transceivers. 7/16 connectors to antennas. N-type duplex receive connectors, also used by HCU, CCB inputs and feedthrough plate.
The SMA connectors are underneath the unit (for ease of connection to the transceivers), and the other connectors on top, as shown in Figure Tech. 5-13. NOTE
All unused SMA inputs to DCF, DDF and HCU modules must be fitted with 50 ohm load terminations.
Tech. 534
29 Jan 2007
GSM
Tx blocks overview
ISOMETRIC VIEW
SMA Tx CONNECTORS FROM TRANSCEIVERS
SIDE VIEW
SMA Tx CONNECTORS FROM TRANSCEIVERS
68P02902W06-C006
Tech. 535
Blanking plate
GSM
Blanking plate
Purpose of blanking plate
The blanking plate is fitted in locations where a Tx block is not required. The blanking plate ensures correct air flow through the cabinet. The plate is attached to the base of the top panel basket using six M4 screws. NOTE
It is important to ensure that all unused Tx block screw locations have a screw in place and tightened to correct torque (see Chapter 1 Overview and specifications). This is to ensure maximum quality of EMC and general containment.
Tech. 536
29 Jan 2007
GSM
Feedthrough plate
Feedthrough plate
Purpose of feedthrough plate
The feedthrough plate converts the normal SMA connector from the transceiver to an N-type connector. Each feedthrough plate has a pair of these converters, one for each of two transceivers. The top N-type connectors are used to connect with either a CCB, or at the (optional) third Tx port on the top of a DDF Tx block. The plate is attached to the base of the top panel basket using six M4 screws.
The Tx outputs of two transceivers, using SMA connectors. Tx inputs of CCBs, or DDFs, using N-type connectors.
68P02902W06-C006
Tech. 537
HCU plate
GSM
HCU plate
HCU overview
The hybrid combining unit (HCU) combines two transceiver Tx outputs. There are six holes for attachment into the bottom of the Tx block basket.
HCU view
Figure Tech. 5-16 shows the HCU plate with connectors identified. Figure Tech. 5-16 HCU plate view showing connectors
M4 HOLES FOR ATTACHMENT
INPUT TO DDF
N-TYPE CONNECTOR
LOAD
Tx
SMA CONNECTORS
Tx
FIRST TRANSCEIVER
SECOND TRANSCEIVER
Tech. 538
29 Jan 2007
GSM
HCU plate
HCU connectors
Each HCU connects to:
S S
The Tx outputs of two transceivers, using SMA connectors. A Tx input of a DDF, using an N-type connector. NOTE
All unused SMA inputs to HCU modules must be fitted with 50 ohm load terminations.
68P02902W06-C006
Tech. 539
TDF
GSM
TDF
Overview of TDF
The purpose of the twin duplexed filter (TDF) Tx block is to enable each antenna to serve one transceiver for both Tx and Rx. The TDF has two identical sections, each providing a single path from a transceiver to a separate antenna. There is no combining in the TDF. The TDF is located in the basket above the transceivers, and attached to the top surface of the top panel using two M6 screws.
TDF view
Figure Tech. 5-18 shows the TDF Tx block with connectors identified.
Tech. 540
29 Jan 2007
GSM
TDF
Rx BANDPASS FILTER
Tx BANDPASS FILTER
Tx FIRST TRANSCEIVER
SMA CONNECTORS
Tx SECOND TRANSCEIVER
TDF connectors
Each TDF connects to:
S S S
The Tx outputs of two transceivers, using SMA connectors. The two connectors are underneath the TDF. Two antennas, each for both Rx and Tx, using 7/16 connectors. These connectors are on top of the TDF. The SURF, using two N-type connectors. These connectors are on top of the TDF.
68P02902W06-C006
Tech. 541
GSM
The dual band TDF is essentially a TDF with one section providing a path for 900 MHz signals and another section providing a path for 1800 MHz signals. There is no combining in the dual band TDF. The dual band TDF is located in the basket above the transceivers, and is attached to the top surface of the top panel using two M6 screws.
Tech. 542
29 Jan 2007
GSM
Tx BANDPASS FILTER
Tx BANDPASS FILTER
Tx
SMA CONNECTORS
Tx
900 TRANSCEIVER
1800 TRANSCEIVER
The Tx output of one 900 transceiver and one 1800 transceiver, using SMA connectors. The two connectors are underneath the dual band TDF. One 900 MHz antenna and one 1800 MHz antenna. Each antenna is used for both Rx and Tx, and each is connected to the dual band TDF using 7/16 connectors. These connectors are on top of the dual band TDF. A SURF module with dual band capability. Two N-type connectors, located on top of the dual band TDF, connect one receive path to the SURFs 900 MHz input and one receive path to the SURFs 1800 MHz input.
68P02902W06-C006
Tech. 543
DCF
GSM
DCF
DCF overview
The purpose of the duplexed combining bandpass filter (DCF) Tx block is to enable each antenna to serve two transceivers for both Tx and Rx. The DCF combines two Tx inputs, dissipating half the power within an internal load. The signal then passes through a bandpass filter and out to the antenna. A receive bandpass filter passes only the Rx signal to the SURF module. The DCF is located in the basket above the transceivers, and attached to the top surface of the top panel using two M6 screws.
DCF view
Figure Tech. 5-22 shows a DCF with connectors identified.
Tech. 544
29 Jan 2007
GSM
DCF
7/16 CONNECTOR
N-TYPE CONNECTOR
DCF
Rx BANDPASS FILTER
Tx BANDPASS FILTER
Tx
SMA CONNECTORS
Tx
FIRST TRANSCEIVER
SECOND TRANSCEIVER
DCF connectors
Each DCF connects to:
S S S
The Tx outputs of two transceivers, using SMA connectors. The two connectors are underneath the DCF. A single antenna for both Rx and Tx, using a 7/16 connector. This connector is on top of the DCF. The SURF, using an N-type connector. This connector is on top of the DCF. NOTE
All unused SMA inputs to DCF modules must be fitted with 50 ohm load terminations.
68P02902W06-C006
Tech. 545
DDF
GSM
DDF
Overview of DDF
The dual-stage duplexed combining filter (DDF) differs from the DCF in having a second stage of combining to allow a third transceiver Tx input. This third Tx input is connected to either:
S
A feedthrough plate connector for a single additional transceiver An HCU plate connector for combining two additional transceivers.
or
S
The DDF is located in the basket above the transceivers, and attached to the top surface of the top panel using two M6 screws.
DDF view
Figure Tech. 5-24 shows a view of the DDF Tx block with connectors identified.
COOLING FINS
Tech. 546
29 Jan 2007
GSM
DDF
Tx BANDPASS FILTER
DDF connectors
Each DDF connects to:
S
The Tx outputs of three or four transceivers, using: Two SMA connectors underneath the DDF. An N-type connector on top of the DDF for connection to a feedthrough plate (for a third transceiver) or HCU plate (for combined third/fourth transceivers).
S S
A single antenna for both Rx and Tx, using a 7/16 connector. This connector is on top of the DDF. The SURF, using an N-type connector. This connector is on top of the DDF. NOTE
All unused SMA inputs to DDF modules must be fitted with 50 ohm load terminations.
68P02902W06-C006
Tech. 547
CCB
GSM
CCB
CCB overview
The Cavity Combining Block (CCB) has EGSM900 and DCS1800 variants. A CCB consists of three independently tuneable cavity resonators, one per CTU. NOTE
CCBs cannot be used with CTU2 transceivers. CCBs are not currently available for the GSM850 or PCS1900 BTS variants.
The CCBs are fitted in the CCB basket in the stacking bracket. The basket can contain up to two CCBs, one for three CTUs. The two CCBs cannot be in different cabinets because of the short phasing lead connecting the two CTUs. Configurations where five or more carriers per sector are required could utilize CCBs. The recommended minimum channel spacing between cavities is 800 kHz. There are two types of CCB:
S S
Master CCB with Band Pass Filter (BPF) and control board. Extension CCB, identical to the master CCB but without the BPF and only having a control board if redundancy is required.
Unlike the Tx blocks, the CCB has no duplexing capability. If a single Rx/Tx antenna is used then connection to the CCB must be through an external high power duplexer.
Tech. 548
29 Jan 2007
GSM
CCB
CCB view
NOTE
CCBs may vary slightly, depending on manufacturer and type.
Figure Tech. 5-26 shows two EGSM900 CCBs with main and redundant control boards fitted.
3 Tx INPUTS CCB CONTROL BOARD (REDUNDANT) PHASING LEAD 3 Tx INPUTS CCB CONTROL BOARD (MASTER)
CCB OUTPUT TO BPF BPF INPUT FROM CCB MASTER CCB WITH BPF POWER LEAD TO BOTH CCB CONTROL BOARDS
ig.317.rh
68P02902W06-C006
Tech. 549
CCB
GSM
Figure Tech. 5-27 shows two DCS1800 CCBs with main and redundant control boards fitted. Figure Tech. 5-27 DCS1800 CCBs with control boards fitted
ANTENNA CONNECTOR
CCB configuration
The master CCB has a second output to enable the extension CCB to be connected. The bandpass filter can then serve both CCBs in parallel. Any unused output is terminated with a short circuit stub. The two configurations are shown in Figure Tech. 5-28. Figure Tech. 5-28 CCB configurations
Tech. 550
29 Jan 2007
GSM
CCB
One cavity retuned and verified Three cavities retuned and verified
8 seconds 19 seconds
68P02902W06-C006
Tech. 551
CCB
GSM
Tech. 552
29 Jan 2007
Chapter 6
Digital modules
68P02902W06-C006
Tech. 61
GSM
Tech. 62
29 Jan 2007
GSM
MCUF B
ALARM MODULE
REDUNDANT (B)
MASTER (A)
ig.322.rh
68P02902W06-C006
Tech. 63
GSM
Support two MCUFs at a BTS site, one master and one slave (for redundancy). Enable master MCUF failure to result in the slave MCUF becoming the master after reset. Enable the OMC-R operator to initiate master/slave MCUF swap. Configure transceivers by the master MCUF. NOTE
Any situation which causes a switch to the redundant MCUF (for example, master MCUF failure or use of the swap_devices command) will cause a site reset.
All four NIUs operate from the master MCUF, but each pair of NIUs depend on a BPSM for power. All NIUs configure to the master MCUF clock. NOTE
When fitting a replacement redundant MCUF, care must be taken to ensure firmware compatibility with the master MCUF. Firmware incompatibility may result in a loss of communication between the two MCUFs so that the redundant MCUF is not in a position to take control in the event of a failure of the master MCUF.
Network interface unit (NIU) Fibre optic multiplexer (FMUX) BPSM (BCU Power Supply Module)
Tech. 64
29 Jan 2007
GSM
68P02902W06-C006
Tech. 65
MCUF
GSM
MCUF
MCUF overview
The main control unit with dual FMUX (MCUF) provides the site processing functions, apart from RF functions of the transceiver. The MCUF also provides switching for up to six network interfaces (including the four NIUs) and up to 24 transceivers. The cabinet may contain up to two MCUF modules, (one master and one for redundancy). Each site and module has an electronic ID for remote identification. The MCUF provides the following functions:
S S S S S S
Maintenance and operational/control processing. Call processing (for example resource management and switching of baseband hopping data). Switching of traffic and control information. Timing reference and network/BTS master clock synchronization. The functionality of two FMUX. Support of up to six transceivers through backplane in first cabinet and up to an additional 18 transceivers including FMUX connections to other cabinets. Support of up to six E1 or T1 circuits, through NIU modules. Support of the CSFP function through the PCMCIA flash memory card. NOTE
If any CTU2 transceivers are installed in the cabinet, a 20 Mbyte PCMCIA memory card running CSFP must be installed in the MCUF to accommodate the use of the CTU2 from a code storage standpoint. If the site is equipped with a redundant MCUF, the PCMCIA is also mandatory for the redundant MCUF.
S S
Tech. 66
29 Jan 2007
GSM
MCUF
The BTP (Base Transceiver Processor) functions and CSFP (Code Storage Facility Processor) functions (provided PCMCIA card fitted), formerly achieved by generic processor boards (GPROCs). The timeslot switch (TSW). The generic clock (GCLK).
S S
BACKPLANE CONNECTORS
STATUS LEDS (RED & GREEN) RESET BUTTONS (FULL - REMOVES SOFTWARE FROM MEMORY CPU RESETS MCUF CPU)
68P02902W06-C006
Tech. 67
MCUF
GSM
2 MAIN PROCESSORS
3 RS232 4 V.28
PCMCIA INTERFACE
FAST FLASH EEPROM SLOW FLASH EEPROM 6 NIU REDUNDANT MCUF SYNC BLOCK FLASH EEPROM RAM 6 EXTERNAL FMUX MODULE TRANSCEIVER x6 IN SAME CABINET GPS 1PPS (IF USED) EXTERNAL CLOCK
ASIC
DEBUG PORT
TRANSCEIVER x6 VIA FMUX IN OTHER CABINETS (OR TCU x6 VIA FMUX IN M-CELL6 CABINETS)
2 FMUX
Tech. 68
29 Jan 2007
GSM
MCUF
The debug port, consists of a TTY connection to the sync processor to access sync firmware, together with other connections to the ASIC and main processors. The Background Debug Mode (BDM) port is used for low level debugging of the main processors.
CAL port
The CAL port on the front panel of the MCUF can be used to calibrate the sync block clock via MMI commands. The 8 kHz reference output is used in the GCLK calibration procedure (see Calibrating the MCUF (GCLK) in the Maintenance Information section of this manual).
PCMCIA interface
The PCMCIA card is located on the front panel of the MCUF, and is used for:
S S
The PCMCIA socket is an industrial standard 68 pin single socket, fitted with an ejector. The PCMCIA interface supports rev 2.1 type I and II cards. The 20 Mbyte card can be write enabled, for upgrade of site information, or disabled to protect card use for other sites or secure the site code.
Technical Description: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Tech. 69
MCUF
GSM
FULL is a hard reset (power up - removes software from the memory). CPU is a soft reset (this resets the MCUF main processors, but the software remains in RAM).
A hard reset results in the software being reloaded to the DRAM in the same way as normal power up. NOTE
During the CPU (soft) reset, pressing CPU reset again will perform a hard reset. Pressing the CPU reset button twice thus has the same effect as a hard reset.
The MCUF has two front panel LEDs (one green and one red) as shown in Figure Tech. 6-3, with indications as shown in Table Tech. 6-2. CAUTION
When red and green LEDs are flashing, the boot code is downloading into non-volatile memory for software upgrade. Do not remove power or reset the cabinet until downloading has been completed, as this will corrupt the non-volatile memory. If boot code is corrupted, contact the Motorola Customer Network Resolution Centre, requesting the boot code restoration procedure and the appropriate boot code file. Table Tech. 6-2 MCUF front panel LED indication Red Green Status Board not powered up or in rest cycle Normal operation Fault condition Non-volatile memory boot code upgrade (Do not remove power nor reset see CAUTION)
PIX interfaces
The MCUF provides four PIX outputs on the backplane, driven at V. 28 levels. The four PIX outputs, routed to the cabinet alarm board, enable relay contact control of external customer equipment.
Tech. 610
29 Jan 2007
GSM
MCUF
Code loading
The boot and executive code, held in the fast flash EPROM, initiates the MCUF on power up or reset. If a PCMCIA memory card is fitted, operational code may be obtained and copied to the DRAM for execution. If no card or code is available, the operational code is obtained from the BSC. Before execution, the operational code held in DRAM is checked with code held at the BSC. The BSC downloads any changed code objects to the DRAM. After successful checking of the DRAM operational code, the code is executed, and the PCMCIA memory card updated with any changed objects.
68P02902W06-C006
Tech. 611
MCUF
GSM
ASIC functionality
The Application Specific Integrated Circuit (ASIC) provides central switching capabilities for the MCUF. It is capable of supporting up to 24 transceivers, together with up to six network interfaces and two links to the on-board processors, one link to the sync processor and a link to the redundant MCUF. The link to the sync processor is used for code loading purposes only. The ASIC supports baseband hopping across the 24 transceiver links. The ASIC provides interface features associated with the transceiver links, these include synchronization features to allow for delay in the link to the transceivers, and the necessary framing and encoding to support the link. All of the serial links into the ASIC are internal lines (I lines), 125 ms framed, with 32 eight bit timeslots per frame.
Link advance/delay compensation. The ASIC will continually measure the round trip delay on each transceiver link to calculate a timing advance for each link. The link advance is applied, and can be adjusted, by the main processor via the processor parallel interface.
BBH data switching. BBH switching is performed automatically on any timeslot configured as BBH data. A single timeslot from the transceiver is selected for BBH routeing information, and defines which transceiver link (0-23) should be used for downlink.
Timing reference insertion. The ASIC receives timing pulses from the sync block and inserts the appropriate bits into the transceiver downlink synchronization and framing timeslots. The sync block will provide a version of the 6.12 s and 60 ms signals that is advanced by 125 ms for this purpose.
Manchester coding/decoding. The transceiver links are all Manchester coded/decoded by the ASIC. This function can be switched on or off (default on) on a per link basis. The disable feature is for applications outside of the MCUF module.
Tech. 612
29 Jan 2007
GSM
MCUF
24 HDLC timeslots for the BCF RSS channel to each transceiver. Four timeslots for NIU control channels (two local, two redundant). Sync processor code load channel. Two channels for RSL links. One HDLC channel occupying up to three timeslots to the redundant MCUF.
2.048 MHz - For serial communications. 16.384 MHz - For FMUX communications. 125 ms - For NIU framing and transceiver framing. 60 ms- For transceiver GSM timing. 6.12 s - For GSM superframe. Six network extracted clocks (E1/T1 source including NIUs). Any of the NIU modules under control of the MCUF can extract a reference clock from an E1/T1 link and pass to the Sync block. CAL port. The CAL port can be used to calibrate the sync block clock through the MMI commands. The reference output provides a monitoring point. Redundant MCUF link.
68P02902W06-C006
Tech. 613
MCUF
GSM
Warm-up The PLL is open loop and using the calibration frequency, but the OCXO is not yet warmed up.
Set frequency The PLL is open loop and using the calibration frequency, and the OCXO is warmed up.
Fast tune Closed loop with wide filter for coarse locking to the reference (extracted from network clock).
Fine tune Closed loop with narrow filter for accurate locking to the reference (extracted from network clock).
When in fine tune closed loop mode, the accuracy is 0.01 ppm.
The boot code, which cannot be altered, queries the main processors on the current version of the sync operational code. If the stored operational code is the correct version, the boot code will move the operational code to RAM and execute the code. If the query results in the need for new operational code, the sync processor will download the operational code from the main processors through the ASIC to the RAM in the sync block. After a successful download, the boot code programmes the flash EPROM with the new operational code and runs the operational code in RAM.
GSM counters
The following counters are provided:
S S
GSM frame incremented every 4.615 ms, range 0 to 1325. GSM superframe incremented every 6.12 s, range 0 to 2047.
Technical Description: Horizonmacro indoor 68P02902W06-C006
Tech. 614
29 Jan 2007
GSM
MCUF
68P02902W06-C006
Tech. 615
NIU
GSM
NIU
Overview of NIU
The network interface unit (NIU) module provides two E1 or two T1 termination links to the terrestrial network. The NIU E1/T1 outputs are connected to a T43 or BIB board, depending on the impedance matching requirement of the customer terrestrial circuits. There are two types of NIU board, one for E1, one for T1. The NIU layout is common to both E1 and T1, the only differences being in the associated crystal oscillators and line matching resistor values. An on-board NIU control processor provides network interface configuration and supervision, controlled by the MCUF.
NIU locations
The cabinet may contain up to four NIU modules in the digital module shelf, as shown in Figure Tech. 6-1. Two NIUs are located in the master (lower) part of the shelf. Two NIUs are in the redundant (upper) part of the shelf, though these upper NIUs are also used for non-redundant purposes. An NIU in slot A0 supports two E1/T1 links. An NIU in slot A1 supports one E1/T1 link. An NIU in slot B0 supports two E1/T1 links. An NIU in slot B1 supports one E1/T1 link.
0 1 2 3
A0 B0 A1 B1
Tech. 616
29 Jan 2007
GSM
NIU
BACKPLANE CONNECTOR
ig.325.rh
The NIU status is indicated by the two front panel LEDs, one green and one red, controlled by the on-board processor, as shown in Table Tech. 6-4.
Table Tech. 6-4 NIU LED display Red LED Off Off Flashing On Green LED Off On Flashing On Status of NIU board NIU not powered up or in reset cycle. Normal operation. NIU undergoing system code download. NIU self testing following switch on or reboot. Red LED extinguishes after 20 seconds, or after 50 seconds following a reboot due to code download.
NIU functionality
The NIU provides two E1/T1 interfaces into the network (link 0 and link 1) as well as LAPD encoding/decoding and clock recovery from a selected E1/T1 link. The second E1/T1 interface (link 1) is not used for NIUs placed in positions at A1 and B1, as shown in Figure Tech. 6-1. An NIU control processor provides network interface configuration and supervision, controlled by the MCUF. The NIU control processor maintains two independent control links in the redundant configuration (one to each MCUF), each using timeslot 0 of MCUF link 0.
Technical Description: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Tech. 617
NIU
GSM
NIU diagram
Figure Tech. 6-6 identifies the functional blocks in the NIU.
Tech. 618
29 Jan 2007
GSM
NIU
Control processor
The control processor interfaces to timeslot 0 of link 0 from each connected MCUF. The processor uses 512 kbytes of flash EPROM for boot code. operational code storage and module ID. Code is executed directly from the Flash EPROM. The boot code can be overwritten under control of the MCUF, if required. The processor also has an on-chip 1 Mbyte of DRAM.
TTY ports
The processing section provides two TTY ports for Motorola debugging purposes only.
Resets
The processor is capable of soft resetting itself. The front panel reset causes a hard reset of the entire board. Power-on also resets the processor. The MCUF is able to reset the NIU through a message on the HDLC link.
REF 125 ms clock signal. The NIU transmit and receive framing is controlled by this 125 ms reference pulse received from the MCUF.
Distance measurement
The NIU provides the ability to perform network distance delay measurement on either of the two network links. Measurement can only be performed on one link at a time. Three modes of operation are possible:
S
Mode 1. A pattern is transmitted in a selected network timeslot and the corresponding receive timeslot is monitored for its return. The delay is measured to an accuracy of 488 ns. The pattern is transmitted on the 6.12 second reference signal. Mode 2. The receive link is monitored for the pattern. When received the pattern is transmitted back in the next frame. The time between receipt and transmission of the pattern is measured to an accuracy of 488 ns. Mode 3. The receive link is monitored for the pattern. When it is detected a strobe is generated for the MCUF sync block.
Technical Description: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Tech. 619
NIU
GSM
RSL link 1 is embedded in the NIU control link; that is, it will be in timeslot 0 of link 0 to the NIU. This link is important for initialization. NOTE
When the NIU is on a network link to a BSC or another BTS, the RSL can be placed on either link on any default timeslot other than zero.
RSL link 2 is on a different timeslot from that used for the network connection.
The NIU supports a maximum of two RSL links. The RSL links may both be on a single network link or shared between the two network links. The NIU hardware supports switching for 64 k and 16 k LAPD channels.
Tech. 620
29 Jan 2007
GSM
Table Tech. 6-5 defines the mapping from the T43/BIB connector to NIU boards.
Table Tech. 6-5 T43/BIB connector to NIU boards
T43 network side connector J1 J2 J7 J8 J13 J14 J4 J5 J10 J11 J16 J17
37-way D-type connections (BIB) 1,20 2,21 7,26 8,27 13,32 14,33 4,23 5,24 10,29 11,30 16,35 17,36
NIU location
NIU identity (MSI) used in commands MSI(NIU) 0 MSI(NIU) 0 MSI(NIU) 2 MSI(NIU) 1 MSI(NIU) 1 MSI(NIU) 3
NIU A0 - Tx1 NIU A0 - Rx1 NIU A0 - Tx2 NIU A0 - Rx2 NIU A1 - Tx1 NIU A1 - Rx1 NIU B0 - Tx1 NIU B0 - Rx1 NIU B0 - Tx2 NIU B0 - Rx2 NIU B1 - Tx1 NIU B1 - Rx1
68P02902W06-C006
Tech. 621
GSM
J1 J2 J7 J8 J13 J14
NIU A0
NIU A1 T43
NIU B0
NIU B1
Tech. 622
29 Jan 2007
GSM
FMUX module
FMUX module
Overview of FMUX module
The fibre optic multiplexer (FMUX) module multiplexes and demultiplexes six, full duplex, transceiver links to one (TX/Rx) pair of fibre optic cables. This enables up to six transceivers in a single extension cabinet (either Horizonmacro or M-Cell6) to be linked to the master cabinet. The FMUX module has two modes of operation:
S S
Working in conjunction with the MCUF to multiplex transceiver links to/from a third extension cabinet. Operating in the extension cabinet to supply the transceivers in that cabinet.
To enable a total of four cabinets to be joined together as one BTS site, an FMUX module is required in the master cabinet to connect the third extension cabinet. A single cabinet site has no need for an FMUX module, because the MCUF connects with the cabinet transceivers through the backplane. Two FMUX modules may be fitted in the digital module shelf, one for the master MCUF, and one for the slave. An extension cabinet only requires one FMUX to connect to six transceivers within the cabinet, (plus one for redundancy if required). Each FMUX fibre optic link is full duplex 16.384 Mbit/s. The FMUX optical link is capable of driving up to 1 km.
BACKPLANE CONNECTOR
FIBRE OPTIC INPUT FROM ANOTHER MCUF/FMUX IN ANOTHER CABINET AT THE SITE
68P02902W06-C006
Tech. 623
FMUX module
GSM
MANCHESTER ENCODED
Tx/Rx
MUX/ DEMUX
2:1 SELECT
TO MCUF (IF MASTER CABINET) TO TRANSCEIVERS (IF EXTENSION CABINET) SELECT CONTROL (FROM MCUF)
Tech. 624
29 Jan 2007
GSM
Alarm module
Alarm module
Alarm module overview
The alarm module is located in the digital module shelf, adjacent to the MCUFs. It provides the cabinet equipment with an external alarm system to report operational status. The alarm module:
S S
Collects all cabinet alarms (received from the backplane). Provides current sensing for 16 customer inputs, referred to as site alarms. These inputs are provided by the PIX connectors PIX0 and PIX1. Controls up to four relay driven outputs linked to customer equipment. (Changeover contacts 30 V 1 A maximum). These outputs are provided by the PIX0 connector. Transmits alarm information to all transceivers in the same cabinet.
BACKPLANE CONNECTOR
5 LED PAIRS
68P02902W06-C006
Tech. 625
Alarm module
GSM
The external alarm connector on the interface panel, (from the optional batery backup system BBS). Cabinet PSMs (identifying type, manufacturer and slot number). Environmental control devices. Customer defined alarms.
The alarm board receives these inputs, encodes them, and then passes the code word to all transceivers in the cabinet through the backplane.
Tech. 626
29 Jan 2007
GSM
Alarm module
1 (top) 2 3 4 5 6 7 8 9 10 (bottom)
Off/Red Off/Red Off/Red Off/Red Off/Red Green/Red Green/Red Green/Red Off/Red Off/Red
Not used in Horizonmacro indoor. Not used in Horizonmacro indoor. Door 1 main cabinet door open alarm. Not used in Horizonmacro indoor. Low voltage disconnect (LVD) alarm (battery backup option). Fan Tray 0 fully operational (4-fan tray). Fan Tray 1 fully operational (2-fan tray). Fan Tray 2 fully operational (2-fan tray). Not used in Horizonmacro indoor. Not used in Horizonmacro indoor.
68P02902W06-C006
Tech. 627
Alarm module
GSM
Tech. 628
29 Jan 2007
68P02902W06-C006
GSM
ii
29 Jan 2007
29 Jan 2007
68P02902W06-C006
iii
GSM
iv
29 Jan 2007
Chapter 1
Routine maintenance
68P02902W06-C006
Maint. 11
GSM
Maint. 12
29 Jan 2007
GSM
Safety
WARNING
Potentially lethal voltages and high energy sources are present in the cabinet when the external ac mains isolator switch is set to the on position and/or batteries are connected. Remove rings, watches and jewellery before starting these procedures, and exercise extreme caution when working on the equipment. Maintenance procedures on this equipment must only be carried out by suitably qualified personnel.
Safety features are built into the equipment to protect against the potentially lethal hazards that exist. All statements regarding safety within these routine maintenance procedures must be adhered to when working on the equipment.
Inform the OMC-R that an equipment safety problem has been identified. Make the equipment concerned safe, for example, by removing power. Make no further attempt to tamper with the equipment. Report the problem directly to GSM Customer Network Resolution Centre +44 (0)1793 565444 (telephone) and follow up with a written report by fax +44 (0)1793 430987 (fax). Collect evidence from the equipment under the guidance of the Customer Network Resolution Centre. Seek local office advice.
Maintenance and Parts: Horizonmacro indoor
S S
29 Jan 2007
68P02902W06-C006
Maint. 13
GSM
Check normal operation, including fans. Also cable integrity and state of all connections.
These procedures are described in subsequent sections of this chapter, one to cover 6 monthly, one 12 monthly, and one 24 monthly.
Maint. 14
29 Jan 2007
GSM
Tool list
Table Maint. 1-2 lists the recommended tools for the Horizonmacro indoor.
Table Maint. 1-2 Horizonmacro indoor tool list Quantity Description Safety goggles Hard hat Dust mask Ear defenders Antistatic wrist strap with coiled lead Antistatic mat Marker pen Torch Socket set (A/F/Metric 13 mm or 1/2 sq drive) 280 mm insulated adjustable spanner Combination spanners A/F: 1/4, 5/16, 3/8, 7/16, 1/2, 9/16, 5/8, 11/16, 7/8, 3/4, 1 Combination spanners metric: 8 mm to 25 mm Ratchet ring spanner (15 mm x 13 mm) Torque spanner (12 mm) Torque wrench (125 Nm) Torxdriver set (T10 to T30) and Security Torxdriver set (T10 to T30) 6 mm torque spanner (for SMA Tx block connectors) Security Allen key set Claw hammer Pipe cutter Junior hacksaw 300 mm hacksaw 150 mm side cutters 150 mm heavyduty side cutters Flush cut wire cutters Light duty cable cutters
68P02902W06-C006
Maint. 15
GSM
Quantity
Description Cable shears Knife with retractable blade General purpose pliers Snipe nose pliers Industrial scissors GP serrated jaw pliers Set of jewellers screwdrivers Screwdriver set (including flat and cross-head blades) Isolating transformer (suitable for site use) Piston drill (suitable for drilling concrete and capable of accepting an M20 drill bit) M20 drill bit Drill bit set 6 m 240 V extension cable (twin outlet) Soldering iron (dual temperature) with holder Coax cable stripper for 2002 (75 ohm coaxial cable) Hand crimp tool Crimp tool for type 43 connectors BNC crimp tool with inserts Telephone plug crimp tool 50 mm crimp tool Cable tie gun 1.5 m wooden step ladder Table vice 250 mm vice grips 7.5 m tape measure 300 mm steel rule Spirit level (1 m) Centre punch Pocket scriber 250 mm half round file Straight point tweezers Null modem RS232 mini tester M to M gender changer
Maint. 16
29 Jan 2007
GSM
Cleaning agents
The following is a list of cleaning and lubricant materials required for routine maintenance:
S S S S S S S S
Dustpan Soft brush Vacuum cleaner Mild detergent De-ionized water Soft cloth Lubricant (WD40 or equivalent) Light grease (TBI or equivalent)
68P02902W06-C006
Maint. 17
GSM
Door operation
The door lock is a trigger latch. To operate the door, perform the following steps: 1. 2. 3. Insert the correct key into the lock and turn. Press middle square panel by the lock to release the lock. Open door to 95_ locking position. CAUTION NOTE 4. 5.
Avoid damaging honeycomb door vent. If the equipment is active, a door open alarm will be signalled to the OMC-R.
To open door to 130_, lift up the middle of the slide arm. To close, lift up the middle of the slide arm, close the door firmly, and lock.
Maint. 18
29 Jan 2007
GSM
Figure Maint. 1-1 Removing and fitting the stacking bracket front cover
REMOVAL
Lift and pull
FRONT COVER
FITTING
To fit the front cover, perform the following steps: 1. Align the four locating clips on the front cover with the four square holes in the front of the stacking bracket. Ensure that the cut out slot on each clip is facing downward. Press the cover against the stacking bracket, so that the cut out slot on each locating clip engages with the bottom edge of each square hole. It may be necessary to gently push in and down to ensure the cut out slots are fully engaged and the cover securely in place.
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
2.
68P02902W06-C006
Maint. 19
GSM
Cleaning air inlets and exhaust grilles. Examining and, if necessary, replacing the optional air filter. WARNING
Potentially lethal voltages and high energy sources are present in the cabinet when the external ac mains isolator switch is set to the on position and/or batteries are connected. Remove rings, watches and jewellery before starting these procedures, and exercise extreme caution when working on the equipment.
Inlets are along the back, sides and front at the base of the cabinet. Air is expelled through the door vent and through the top panel beneath hood or stacking bracket. The following procedure should be followed to clean inlets and exhaust grilles:
S S
Use vacuum cleaner or brush to ensure bottom inlets are clear of debris. Open door and clean aluminium door vent, taking care to avoid damage.
If a filter is fitted, remove two front M6 screws to allow filter holding plate to drop down. Remove filter, examine and, if dirty, replace with a new filter. Replace filter (original or new) then lift up holding plate and secure with the two M6 screws. Tighten to correct torque (see Technical Description Overview and specifications). Close and secure the door.
Maint. 110
29 Jan 2007
GSM
6-monthly procedures. Checking and cleaning fans. Checking normal operation. Annual check of the installation. WARNING
Potentially lethal voltages and high energy sources are present in the cabinet when the ac mains isolator switch is set to the on position and/or batteries are connected. Remove rings, watches and jewellery before starting these procedures, and exercise extreme caution when working on the equipment.
There are three cabinet fan modules, one 4-fan unit and two identical 2-fan units. Table Maint. 1-3 shows the three fan positions.
Table Maint. 1-3 Fan positions Fan reference Type of module Cabinet position
0 1 2
Right side, beneath digital cage. Middle, beneath transceivers. Left side, beneath transceivers.
Remove the fan module by lifting the central slide latch and pulling out. Use a brush and vacuum cleaner to remove any dust and dirt on the module. Refit fan and check operation. Any fan not operating should be started by using the appropriate RESET button. Observe the fans through the grilles to ensure correct operation. Listen for excessive noise. If there is excessive noise, identify fan and replace fan module (see Replacing a fan module).
68P02902W06-C006
Maint. 111
GSM
Figure Maint. 1-2 Cabinet modules with door and hood removed
ONE SURF (Rx) THREE Tx BLOCKS (DCFs SHOWN AS EXAMPLE) SIX TRANSCEIVERS (CTU/CTU2s) THREE PSMs (see NOTE) CIRCUIT BREAKER MODULE (CBM) T43/BIB DC POWER IN INTERFACE PANEL CONNECTORS
NOTE
Maint. 112
29 Jan 2007
GSM
2.
Transceivers in locations 0 to 5
Tx status (ORANGE) or Operational status (GREEN). Top LED (GREEN). GREEN. 6, 7, 8 GREEN (fans) 3 RED (as door is open)
PSMs in locations 0 to 2 Digital modules (NIU, MCUF, FMUX, BPSM) Alarm module
68P02902W06-C006
Maint. 113
GSM
Power down cabinet. Earth continuity check. Power system insulation check. Check of electricity company connection. Pre-power up check of supply and earth connection security and condition. Power up of cabinet.
Log the maintenance activity. After procedures have been completed, restore the cabinet to operational state and notify the OMC-R of base station availability.
Visual inspection
Inspect the installation for damage in accordance with BS 7671 (16th Edition <Section 712>) or the IEC 364 equivalent. WARNING
If damage is discovered during the visual inspection, the commissioning must not proceed further until the damage has been inspected and rectified by the manufacturers or their representatives.
Cabinet exterior
Examine the exterior of the cabinets for structural, paint or mechanical damage and report any damage to Motorola.
Cabinet interior
Examine the interior of the cabinet for structural, paint or mechanical damage and report any damage to Motorola.
Power equipment
Examine the power equipment for mechanical damage and report any damage to Motorola.
Maint. 114
29 Jan 2007
GSM
Antenna feeders. AC supply input earth. The local electricity board termination point. AC distribution board. AC supply isolator.
The switched isolator will not be connected to earth if it is a double insulated device and will therefore not require testing.
NOTE
S S S S
Battery box chassis. Cabinet chassis (all cabinets). +27 V power supply unit chassis. Rack members.
Check that the measured resistance is less than 0.1 ohms with the tester connected to a conductive surface (bare metal) at extreme ends of the earth cables. On completion of each earth check apply conductive non-oxidizing grease to the earth connections on the earth busbar.
500
0.5
68P02902W06-C006
Maint. 115
GSM
Power up procedure
The following procedure should be carried out to power up the cabinet. Figure Maint. 1-3 shows the cabinet components and enlarged view of CBM showing circuit breaker buttons. Figure Maint. 1-3 Diagram of cabinet with expanded view of CBM
SURF
7A
CCB (0 AND 1)
4A
SURF
2A
BPSMs (A AND B)
7A
6 TRANSCEIVERS (0 TO 5)
ig.281.rh
12 A
TRANSCEIVER 0
Maint. 116
29 Jan 2007
GSM
CAUTION
Power up of cabinet
To power up the cabinet, proceed as follows: CAUTION
When the two LEDs of the transceiver or the MCUF are flashing, the boot code is downloading into non-volatile memory for software upgrade. Power should not be removed, nor the cabinet reset, until downloading has been completed, as this will corrupt the non-volatile memory. If boot code is corrupted, contact the Motorola Customer Network Resolution Centre and request the boot code restoration procedure and the appropriate boot code file.
1. 2. 3.
Switch on the external power supply to the cabinet. Turn each PSM switch to the OUTPUT ENABLE position; check that each PSM has the active (green) LED on and the alarm (red) LED off. Press the CBM circuit breaker button marked FANS. Check that each fan module is operating correctly. Activate any fan not started by the restart button (marked either FRONT or REAR) on the fan module. Press the CBM circuit breaker button marked SURF, and if CCBs are fitted, press the circuit breaker buttons marked CCB0 and CCB1.
4.
68P02902W06-C006
Maint. 117
GSM
5.
Press the CBM circuit breaker button marked BPSM A and (if redundant BPSM fitted) BPSM B. Check all associated digital module LEDs operate correctly; green LEDs lit on BPSM, NIU and MCUF, and red LEDs off on NIU and MCUF. MCUF initialization will commence at power up. A connection to the BSC will be established and code download will take place. After download the site will be initialized. NOTE
The NIU module will initially show both red and green LEDs lit while the unit conducts a self test. When rebooting due to a code download, the red LED extinguishes after approximately 50 seconds. If the code is a different version, the non-volatile memory will be upgraded at this point. Both LEDs will be flashing, and a warning message will appear on the PC terminal. Do not power down or reset the cabinet as this will corrupt the non-volatile memory. If this happens, contact Motorola Customer Network Resolution Centre and request the boot code restoration procedure and the appropriate boot code file.
CAUTION
6.
Press the CBM circuit breaker buttons for the appropriate transceivers fitted, and check that the RADIO STATUS LED for each transceiver flashes green. At this point, after the MCUF has initialized, the transceivers will download code from the MCUF. CAUTION
If the code is a different version, the non-volatile memory will be upgraded at this point. Both LEDs will be flashing. Do not power down or reset the cabinet as this will corrupt the non-volatile memory. If this happens, contact Motorola Customer Network Resolution Centre and request the boot code restoration procedure and the appropriate boot code file.
7. 8. 9.
Once fully initialized, all transceivers should have RADIO STATUS LED solid green, and TRANSMIT STATUS LED either off or solid yellow. Disconnect the 9 to 9-way cable from the MCUF TTY port. Close the door to ensure correct ventilation.
Maint. 118
29 Jan 2007
GSM
6-monthly procedures. 12-monthly procedures. Mechanical inspection of cabinet, including inspection and lubrication of locks and hinges.
68P02902W06-C006
Maint. 119
GSM
Check exterior panels and hood/stacking bracket for dents and structural damage. Check cabinet top connections for signs of overheating and security of attachment.
Check cabinet door for distortion, security and correct operation. Check hinges for damage, security and correct operation. Carefully lubricate the hinges. Ensure that all door seals are wiped clean of the lubricant. Check earth connection for damage and security. Check door lock mechanism and inspect for ease of operation. Lubricate the mechanism with light grease. Ensure that lubricated surfaces are grit-free.
S S
Check all rack equipment for security of attachment, especially PSM, CBM and transceiver attachment screws using a Torxdriver. Tighten to the correct torque (see Technical Description Overview and specifications). Carry out a visual check of all wiring for signs of overheating and security of attachment. WARNING
Do not overstress the earth connections as this may damage the connector and reduce the protective function.
Check the earth connections for corrosion and tightness using a torque spanner. Tighten to the correct torque (see Technical Description Overview and specifications).
Maint. 120
29 Jan 2007
Chapter 2
68P02902W06-C006
Maint. 21
GSM
Maint. 22
29 Jan 2007
GSM
This chapter provides information on replacement of field replaceable units (FRUs). Only components classed as FRUs are detailed in this chapter. Any requirement to open or close a door, or remove and replace the optional hood, is assumed in procedures. Shutting the door, or replacing the hood is assumed at the end of any procedure. SURF module and Tx block replacement may be carried out with the stacking bracket in place, but the CCB basket (if fitted) must be removed, (see Replacing a CCB ). For door opening, or hood or stacking bracket removal, see Routine maintenance overview. Where customers wish to perform a minor repair on an FRU, in order to save the cost of full replacement, they should consult Motorola for more detailed procedures or replacement components (see Additional replacement parts).
FRU list
The following is a list of FRUs used in this equipment:
S S S S S S S S S S S S S
Door. Heat sensor modules. Hood. Stacking bracket. Fan units. Circuit breaker module (CBM). Power supply module (PSM). Hold-up battery module. Transceiver (CTU or CTU2). SURF module. Tx blocks, including feedthrough plate. CCBs (installed in stacking bracket basket as CCB FRU). Digital modules (MCUFs, NIUs, FMUXs, alarm board and BPSMs).
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 23
GSM
Torque values
Table Maint. 2-1 details torque values used during repair procedures.
Table Maint. 2-1 Torque values for all cabinet screws/bolts and RF connectors Size of screw/bolt M4 M6 M8 M10 SMA N-type 7/16
Torque value
2.2 Nm
3.4 Nm
5 Nm
10 Nm
1 Nm
3.4 Nm
25 Nm
Maint. 24
29 Jan 2007
GSM
Figure Maint. 2-1 Cabinet, without door or hood, showing FRU components
ONE SURF (Rx) THREE Tx BLOCKS (DCFs SHOWN AS EXAMPLE) SIX TRANSCEIVERS (CTU/CTU2s) THREE PSMs (see NOTE) CIRCUIT BREAKER MODULE (CBM) T43/BIB DC POWER IN INTERFACE PANEL CONNECTORS
NOTE
68P02902W06-C006
Maint. 25
GSM
Items unlikely to fail, but replacement of which is essential if failure occurs. Subsections of FRUs, where local conditions may make it more economical to repair the FRU. CAUTION
Only qualified personnel should attempt non-FRU replacement, in order to minimize risk of equipment damage. For example, the CBIA main cage requires care in removal and installation, and Individual fans require care in ensuring correct direction of airflow.
Door lock. Individual fans within a fan module. Any part of the CBIA: main cage, harness, door sensor, interface panel, or backplane.
Seven M4 screws to SURF harness (two guide pins lock cage into position). Four M6 (left side) and five M6 (right side) screws at cabinet front. Eight M6 T30 screws for interface panel attachment to top panel.
Maint. 26
29 Jan 2007
GSM
Replacing a door
Replacing a door
Introduction to door replacement
The door is essential to the correct operation of the ventilation system. The door also provides protection to equipment inside. For these reasons, the replacement procedure should be completed in one session, and the cabinet then secured.
Views of door
Figure Maint. 2-2 shows an inside and outside view of the door.
EXTERNAL VIEW
HONEYCOMB VENTILATION
VENTILATION GRID
TRIGGER LATCH
ig.266.rh
68P02902W06-C006
Maint. 27
Replacing a door
GSM
Replacement of door
Removing a faulty door
To remove a door, open and perform the following steps: 1. 2. 3. At the cabinet, unscrew M6 nut, holding the door earth cable to the cabinet. Retain nut for re-use. Unscrew M6 holding screw on slide arm several turns, then unhook slide arm from the cabinet attachment point by lifting up. Move door to about 90 and lift door off hinges.
To install a replacement door, proceed as follows: 1. 2. 3. Hold door at about 90 and lift onto door hinges. Attach the door earth cable to the cabinet by using the M6 nut. Tighten to the correct torque (see Overview of replacement procedures). Place the slide arm onto the cabinet attachment holding point and apply several turns of the M6 holding screw.
Maint. 28
29 Jan 2007
GSM
1. 2. 3. 4. 5.
Remove the transceivers (see Replacing a transceiver). Identify the faulty heat sensor. Remove the faulty heat sensor by pulling. Install the replacement heat sensor by pushing firmly into place. Install the transceivers (see Replacing a transceiver).
68P02902W06-C006
Maint. 29
Replacing a hood
GSM
Replacing a hood
Introduction to hood replacement
This procedure assumes an optional hood is already fitted, with hood pins located in the correct cabinet locations. If the hood is to replace a stacking bracket, refer to the appropriate procedures in this chapter Replacing a stacking bracket and Installation and Configuration: Horizonmacro 68P02902W08 Chapter 2, Hood or stacking bracket fit.
View of hood
Figure Maint. 2-3 shows a top view of the hood.
ig.333.rh
Maint. 210
29 Jan 2007
GSM
Figure Maint. 2-4 Stacking bracket view with optional CCB basket
M10 HOLES (4) FOR TOP CABINET ATTACHMENT (IF REQUIRED) REAR OF BRACKET
68P02902W06-C006
Maint. 211
GSM
If an upper cabinet is fitted on top of stacking bracket, decommission the cabinet as described in Installation and Configuration: Horizonmacro 68P02902W08 Chapter 5 Decommissioning Horizonmacro indoor. If a CCB is fitted, remove it (see Replacing a CCB). Loosen and remove the eight M8 screws holding the faulty bracket. WARNING
The stacking bracket can weigh as much as 15 kg (more if CCB is contained in CCB basket). Observe the correct lifting precautions.
3. 4.
5. 6.
Lift the faulty stacking bracket off the cabinet. Align the replacement stacking bracket onto the cabinet, and fit the eight M8 screws. Tighten to correct torque (see Overview of replacement procedures ). Install and commission any upper cabinet removed in step 2 as described in Installation and Configuration: Horizonmacro 68P02902W08 Chapter 2 and Chapter 3. Refit the front cover by attaching to side lugs and pushing into position.
7.
8.
Maint. 212
29 Jan 2007
GSM
4-FAN UNIT
RESET BUTTONS (ONE PER FAN)
68P02902W06-C006
Maint. 213
GSM
0 1 2
Right side, underneath digital cage. Middle, beneath transceivers. Left side, beneath transceivers.
To replace the fan, perform the following steps: 1. 2. 3. 4. Lift the central slide latch. Pull out the fan module. Insert the replacement module firmly in place, ensuring the slide latch has engaged. Ensure all fans are operating. Any fan not operating should be started by using the appropriate RESET button.
Maint. 214
29 Jan 2007
GSM
Views of CBM
Figure Maint. 2-6 shows views of the CBM with circuit breaker buttons identified.
Figure Maint. 2-6 Views of CBM with circuit breaker buttons identified
BACKPLANE CONNECTOR HANDLE-BAFFLE
4A
CCB (0 AND 1)
2A
7A
7A
BPSMs (A AND B)
12 A
6 TRANSCEIVERS (0 TO 5)
SURF FANS
FRONT VIEW
68P02902W06-C006
Maint. 215
GSM
Replacing a CBM
To replace a CBM, proceed as follows: 1. 2. 3. 4. 5. 6. 7. Verify that the power source isolator is switched to OFF, and locked (if possible). Set the switch of each PSM to the OUTPUT DISABLE position. Unscrew both CBM module attachment screws (shown in Figure Maint. 2-6), using a torxdriver. Pull out module, using handle-baffle. Press and release all push on/push off circuit breaker buttons of the new CBM module into the out (off) position. Insert the replacement module and press firmly into place. Tighten both module attachment screws to correct torque (see Overview of replacement procedures), using an M4 Torx driver. Switch on the external power supply to the cabinet. Turn each PSM switch to the OUTPUT ENABLE position. Check that each PSM has the ACTIVE (green) light on and the ALARM (red) light off. Press the CBM isolator marked FANS. Check that each fan, eight in total, is operating correctly. Any fan not started may be activated by the reset button (marked either FRONT or REAR) on the appropriate fan unit. Press the CBM circuit breaker button marked BPSM A and (if redundant BPSM fitted) BPSM B. Check all associated digital module indicators operate correctly. Press the CBM circuit breaker button marked SURF, and if CCBs fitted the circuit breaker buttons marked CCB0 and CCB1. Press the appropriate CBM circuit breaker buttons for the transceivers fitted, and check that the LEDs for each transceiver indicate correct operation. Close the door to ensure correct ventilation.
4.
5. 6.
7.
This completes the CBM replacement and power up sequence for a cabinet.
Maint. 216
29 Jan 2007
GSM
View of PSM
Figure Maint. 2-7 shows a view of the PSM with key features identified. Figure Maint. 2-7 View of PSM with key features identified
AIR VENTS ON ENTIRE TOP AND BOTTOM PANELS
NOTE
There are several manufacturers of the PSMs. All PSMs of the same type are fully compatible with each other, regardless of manufacturer.
68P02902W06-C006
Maint. 217
GSM
5. 6.
7. 8. 9.
3. 4.
5.
Maint. 218
29 Jan 2007
GSM
Proceed as follows to replace a hold-up battery module: 1. 2. Verify that the enable switch of the replacement hold-up battery module is set to O. Cut the cable tie that secures the jumper lead to the isolation connection access hatch. Open the access hatch by turning the fastener a quarter turn anticlockwise and lifting. Fit the jumper lead between the battery spade terminals as shown in Figure Maint. 2-8. Close the access hatch and turn the fastener a quarter turn clockwise to secure. Set the enable switch of the faulty hold-up battery module to O (off). The ACTIVE LED (green) will extinguish (the green LED may already be off, if a fault has resulted in output failure). The ALARM LED (red) will light, or if already lit due to alarm state, will stay on. WARNING 5. 6. 7.
The hold-up battery module weighs 5.9 kg. Handle with care.
3.
4.
Unscrew the module attachment screws using a torxdriver, and remove the module. The red LED will go off. Insert the replacement hold-up battery module. Ensure the replacement hold-up battery module is firmly in position and tighten both module attachment screws using a torxdriver. Tighten to a torque of 2.2 Nm. Set the hold-up battery module enable switch to I (on). Check that the CHARGE LED (green) is lit. NOTE
The ACTIVE LED (green) will not light until 1.5 to 2 hours after installation. The ALARM LED (red) may also be lit if the initial battery voltage is below 19 V dc (+/0.25 V).
8.
9.
Remove the battery isolation jumper lead from the faulty hold-up battery module and secure it to the outside of the access hatch before transportation.
68P02902W06-C006
Maint. 219
GSM
Figure Maint. 2-8 shows the battery hold-up with the battery isolation jumper connection shown in detail.
JUMPER LEAD
Maint. 220
29 Jan 2007
GSM
Replacing a transceiver
Replacing a transceiver
Preconditions for transceiver replacement
There are up to six transceivers in a cabinet, which may be all CTUs, all CTU2s, or a mix of the two. Replacing a transceiver requires removal of RF transmitter power for that transceiver; it is therefore advisable to perform this procedure during periods of low traffic. The OMC-R should be notified of imminent repair activity. NOTE
The transceiver replacement procedure is the same for all transceivers, regardless of frequency rating. Read the Preserving transceiver calibration section later in this chapter prior to removing the module.
View of a CTU
Figure Maint. 2-9 shows a view of a CTU with key features identified.
Tx OUT CONNECTOR
RADIO STATUS LED RECESSED MANUAL RESET BUTTON (if fitted) Tx STATUS LED
68P02902W06-C006
Maint. 221
Replacing a transceiver
GSM
View of a CTU2
Figure Maint. 2-10 shows a view of a CTU2 with key features identified.
Tx OUT CONNECTOR
Rx D Rx A Rx C Rx B
Maint. 222
29 Jan 2007
GSM
Replacing a transceiver
To remove a transceiver, proceed as follows: 1. Locate the transceiver to be replaced. They are sequentially numbered, with transceiver 0 on the right, and transceiver 5 on the left, as shown in Figure Maint. 2-1. Disable the transceiver transmit RF power by using the lock_device or shutdown_device command at the OMC-R or from a PC connected to the MCUF. NOTE
Refer to Technical Description: BSS Command Reference 68P02901W23 for information on usage and specific commands.
2.
3. 4.
When the transceiver has been shutdown, check the Tx STATUS LED (solid yellow) is unlit. Press and release the appropriate transceiver circuit breaker button on the CBM to the out (off) position. Ensure the RADIO STATUS LED is unlit. WARNING
Ensure that RF power is OFF, before disconnecting RF cables. Severe burns may result if RF power is ON when cables are disconnected.
5. 6.
Unscrew the coaxial cable from the Tx OUT SMA connector at the top of the transceiver front panel. Unscrew the two transceiver attachment screws using M4 Torx driver. WARNING CAUTION
The transceiver weighs 5 kg. Handle with care. Take care to avoid damage of transceiver rear connectors when handling outside of the cabinet.
7.
Withdraw the transceiver using the handle. Support the unit from underneath as it slides out.
68P02902W06-C006
Maint. 223
Replacing a transceiver
GSM
3. 4.
5.
Screw the 90 SMA connector of the coaxial cable onto the Tx OUT SMA connector at the top of the transceiver front panel. Tighten to correct torque (see Overview of replacement procedures). Press and release the appropriate transceiver circuit breaker button on the CBM. The RADIO STATUS LED will flash green for about two minutes, and then remain lit. CAUTION
If both RADIO STATUS and Tx STATUS LEDs are flashing, the bootcode is downloading into non-volatile memory for software upgrade. Power should not be removed, nor the cabinet reset, until downloading has been completed, as this will corrupt the non-volatile memory. If bootcode is corrupted, contact Motorola Customer Network Resolution Centre requesting the bootcode restoration procedure and the appropriate bootcode file.
6.
7.
Enable the transceiver transmit RF power by using the unlock_device or ins_device command at the OMC-R or from a PC connected to the MCUF. The Tx STATUS LED (yellow) will be lit if the transceiver is transmitting. Calibrate the transceiver using the appropriate procedure, as described in Transceiver calibration data exchange procedures later in this chapter. Notify the OMC-R of base station availability and log the maintenance activity.
8. 9.
Maint. 224
29 Jan 2007
GSM
68P02902W06-C006
Maint. 225
GSM
Maint. 226
29 Jan 2007
GSM
If a transceiver malfunctions and has Preserve to be replaced, the associated DRI is transceiver locked and the malfunctioning calibration data transceiver replaced with a new transceiver while the cell remains in service. The DRI is then unlocked. When the executive message Radio Standby Success is received by the CA at the BTS, the database is queried to determine if any valid offset data is stored. If any is found in the database, this is downloaded to the new transceiver and the transceiver is allowed to come into service (B-U). Once the CA at the BTS receives the Transceiver executive message Radio Standby calibration Success, it checks the CM database for valid offsets. If none exist, the BTS then queries the transceiver for valid data. If none exists in the transceiver, the transceiver is brought into service but the Invalid transceiver calibration data alarm is triggered. Initially a transceiver is calibrated and Transceiver the antenna offsets stored within the recalibration transceiver. When the BTS initializes and enters call processing mode, the Central Authority (CA) at the BTS queries Configuration Management (CM) to see if valid offset data exists. If no valid data exists then the transceiver(s) are queried for the offset data, which is sent through the Radio Signalling Link (RSL) to the CM at the BSC.
invalid/no calibration data held in the CM database and invalid/no calibration data in the transceiver.
invalid/no calibration data held in the CM database, but with valid calibration data in the transceiver.
68P02902W06-C006
Maint. 227
GSM
is:
site dri device first dev_id second dev_id third dev_id
System response:
DRI ID 5 3 0 Data read from transceiver Calibration data (All values in Hex): Transmit Power Offset = 77 Receive System Data: Antenna Number 1 2 3 4 5 6 73, 77, 74, 7E, 70, 81, 77, 81, 71, 76, 6D, 74, 74, 6F, 68, 69, 70, 83, 6D, 55, 56, 57, 55, 68, 67, 65, 66, 56, 80, 77, 66, 6C, 5F, 66, 78, 54, 67, 66, 56, 5F, 6C, 6D, 77, 5F, 66, 87, 9D, 56, 66, 66, 65, 64, 62, 44, 54, 5A, 5D, 5F, 60, 55, 55, 43, 44, 4D, 4E, 44, 65, 6F, 6D, 67, 77, 81, 66, 45, 4F, 4D, 44, 4A, 61, 60, 64, 66, 6D, 64, 54, 5D, 55, 5F, 60, 5B, 5D, 55, 5A, 67, 6F, 60,
Note that the second line of the system response indicates whether the data is read from the transceiver or the database. In the example above the information is read from the transceiver. The number of rows of offset calibration data are as follows:
S S S S S
Maint. 228
29 Jan 2007
GSM
An IBM-compatible personal computer (PC). Terminal emulator software. A 9-way to 9-way cable (BTS). A 9-way to 25-way cable (BSC).
Commands used
Table Maint. 2-4 lists the commands required to carry out this procedure.
Table Maint. 2-4 Transceiver calibration commands BTS Command Function Prevents the device being used (see Note below). Enables the device to be used (see Note below). Function
lock_device unlock_device
OMC-R/BSC Command
disp_cal_data
When transceiver is locked: Displays calibration data in the CM database for the specified transceiver. When transceiver is unlocked: Displays calibration data in the RAM of the specified transceiver. for a specified transceiver.
clear_cal_data Clears calibration data in the CM database at the BSC and BTS NOTE
Use shutdown_device instead of lock_device if the transceiver is currently active. Use ins_device instead of unlock_device if shutdown_device was used to lock the transceiver. If there is no RSL from the BTS to the BSC then a command will not be executed by the BSC, as the BSC has no knowledge of the command being entered.
NOTE
All calibration data is stored in the master CM database at the BSC, which is then used to update the CM database copy at the BTS only if the data is valid.
68P02902W06-C006
Maint. 229
GSM
Determine the BSC/BTS configuration and cage slot allocation before starting any of the calibration data exchange procedures. NOTE
Calibration data is interchangeable between the CTU and CTU2 transceivers. This means that a CTU2 can be used to replace a CTU and the original CTU calibration data used.
Maint. 230
29 Jan 2007
GSM
To replace a transceiver using preserved calibration data, follow the procedures for transceiver replacement given previously in Replacement procedure for transceiver. The calibration data stored in the CM database is downloaded into the RAM of the new transceiver. The data is also stored in the non-volatile transceiver memory. NOTE
After the transceiver has been replaced, it will still be necessary to revisit the site at an off-peak hour, to carry out bay level and CSPWR calibration to fully optimize the hardware.
68P02902W06-C006
Maint. 231
GSM
1.
Lock all the DRIs in the same sector of the transceiver to be calibrated. Always lock the transceiver providing the BCCH last, as this prevents the BCCH switching to an alternative transceiver. Enter the following command for each of the DRIs. lock_device <location> DRI <device_id1> <device_id2> [<device_id3>]
2. 3.
Display the data in the CM database for the transceiver to be calibrated: disp_cal_data <location> DRI <device_id1> If valid data is present, proceed to step 4. If the response seen is:
NO CALIBRATION DATA AVAILABLE
Enter the following: store_cal_data <location> 4. Check there is calibration data present in the CM database for the DRI, then clear that data for the transceiver to be calibrated: clear_cal_data <location> DRI <device_id1> 5. Confirm the data has been cleared from the CM database for the specified transceiver: disp_cal_data <location> DRI <device_id1> If no problems have occurred, the response will be:
NO DATA AVAILABLE
NOTE 6.
If there is a different response, ensure the transceiver is in the LOCKED state and carry out from step 2 again.
Carry out bay level and CSPWR procedures, as described in the relevant section of this manual. Record the data.
Maint. 232
29 Jan 2007
GSM
Enter the command: unlock_device <location> DRI <device_id1> Check that the calibrated transceiver passes into BUSY-UNLOCKED state. The new calibration data is uploaded to the CM database and is then used to update the copy at the BTS. 2. Check the calibration data of the DRI of the calibrated transceiver against the values noted in step 6 of the previous procedure. NOTE
Allow one minute after uploading for the values in the CM database at the BSC to be updated.
Enter the command: disp_cal_data <location> DRI <device_id1> The values seen should match the previous ones. NOTE
If the transceiver is BUSY-UNLOCKED the data can be read directly from the transceiver. In ENABLED-UNLOCKED or LOCKED state calibration data is read from the CM database.
3.
Make test calls in all timeslots of the new DRI to check audio quality and then lock the tested DRI using the command: lock_device <location> DRI <device_id1> With the transceiver LOCKED (or in ENABLED-UNLOCKED state), ensure the calibration process has been carried out correctly by checking that the CM database at the BSC has been updated with the new values. Enter the command: disp_cal_data <location> DRI <device_id1> The values seen should match the previous ones.
4.
5.
If everything is in order, the cell can be put back into service. Unlock all the DRIs in the same sector that were locked previously using the command: unlock_device <location> DRI <device_id1> <device_id2> [<device_id3>]
68P02902W06-C006
Maint. 233
GSM
Enter the following: store_cal_data <location> 5. Check there is calibration data present in the CM database for the DRI, then clear that data for the transceiver to be recalibrated: clear_cal_data <location> DRI <device_id1> 6. Confirm the data has been cleared from the CM database for the specified transceiver: disp_cal_data <location> DRI <device_id1> If no problems have occurred, the response will be:
NO DATA AVAILABLE
NOTE 7.
If there is a different response, ensure the transceiver is in the LOCKED state and proceed from step 3 again.
Carry out bay level and CSPWR procedures, as described in the relevant section of this manual. Record the data.
Maint. 234
29 Jan 2007
GSM
Enter the command: unlock_device <location> DRI <device_id1> Check that the recalibrated transceiver passes into UNLOCKED state. The new calibration data is uploaded to the CM database and is then used to update the copy at the BTS (even if the DRI does not have an RTF assigned). 2. Check the calibration data of the DRI of the recalibrated transceiver against the values noted in step 7 of the previous procedure. NOTE
Allow one minute after uploading for the values in the CM database at the BSC to be updated.
Enter the command: disp_cal_data <location> DRI <device_id1> The values seen should match the previous ones. NOTE
If the transceiver is BUSY-UNLOCKED the data can be read directly from the transceiver. In ENABLED-UNLOCKED or LOCKED state calibration data is read from the CM database.
3. 4.
Lock the tested DRI using the command: lock_device <location> DRI <device_id1> With the transceiver LOCKED (or in ENABLED-UNLOCKED state), ensure the recalibration process has been carried out correctly, by checking that the CM database at the BSC has been updated with the new values. Enter the command: disp_cal_data <location> DRI <device_id1> The values seen should match the previous ones.
5.
If everything is in order, the cell can be put back into service. Unlock all the DRIs in the same sector that were locked previously using the command: unlock_device <location> DRI <device_id1> <device_id2> [<device_id3>]
68P02902W06-C006
Maint. 235
GSM
Follow the appropriate CTU or CTU2 procedure to calibrate the bay level offset tables to compensate for the losses or gains due to preselectors and RF cabling from the antenna inputs at the Horizonmacro to the transceiver input. All units are factory calibrated. This procedure is thus necessary only if one of the following changes occur:
S S S S
A transceiver is replaced. RF front end equipment is changed. The site is reconfigured. High power duplexers are fitted. NOTE
The procedures contained in Calibrating transceiver bay level offset tables are to calibrate a single transceiver. Repeat the procedures for all transceivers affected by the changes listed above.
An IBM-compatible personal computer (PC). Terminal emulator software. A 50 ohm 50 W dummy load. A signal generator (0 to 2 GHz). A 9-way to 9-way MCUF/transceiver cable. A 9-way to 9-way EQCP/RSS (CTU) or DSP MMI/RSS (CTU2) transceiver cable. NOTE
The EQCP/RSS cable (for CTU) and DSP MMI/RSS cable (for CTU2) are actually the same cable, it is only the nomenclature that is different. All test equipment and test leads must be calibrated annually by a recognized laboratory. Test equipment and test leads must not be calibrated in the field. Do not optimize Motorola cellular base stations with test equipment that is beyond its calibration due date. Allow test equipment to warm up for 30 minutes before use.
CAUTION
Maint. 236
29 Jan 2007
GSM
Commands used
Table Maint. 2-5 lists the MMI commands used to carry out the procedure. NOTE
1. The symbol 0 used in the commands in this procedure is a zero. 2. BSS MMI commands may be entered in upper or lower case. All other commands must be entered in the case shown below. CTU passwords are not case sensitive.
Table Maint. 2-5 MMI commands for CTU bay level offset calibration BSS MMI command Function Initializes the device, bringing it into service. Prevents the device being used. Frees the device for further use. Clears previously stored calibration data for a specified radio unit on a per DRI basis. Function Places the CTU into test mode. Inhibits the BBH alarm. Calibrates the bay level receive equipment. Disables automatic intermodulation compensation. Activates the Control Processor. Sets all timeslots to channel #. Sets all timeslots to antenna #. Stops synthesizer switching with synth 1 permanently on. Enables synthesizer switching into normal working. Transfers bay level calibration stored data in RAM to FLASH EPROM. Informs control processor that bay level calibration is valid for branch N and sets bay level flag. Stops the control processor. Write enables the FLASH EPROM. Write protects the FLASH EPROM. Reads cal bay offsets from FLASH EPROM. Reads cal bay offsets from RAM. Function Stops the CTU hunting between fibre A and fibre B and forces the CTU to look only at fibre A.
TEST
BBH ALARM OFF
tcu_clock 0
68P02902W06-C006
Maint. 237
GSM
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna. The CTU must be brought into service as there is no flash EPROM storage of code at the transceiver control processor level. If a connection to the BSC is not available a PCMCIA commissioning card must be used.
NOTE
4.
Wait for the radio to finish initializing, then lock the cell using the lock device command. WARNING
Failure to lock the cell could result in the BCCH transmitting into, and causing damage to the signal generator. Maintenance personnel could receive RF burns when connecting to the antenna socket.
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna. For ease of calibration, all CTUs in a cell should be initialized and then locked. Always lock the transceiver providing the BCCH last as this prevents the BCCH being switched to alternate transceivers.
NOTE
Maint. 238
29 Jan 2007
GSM
5.
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna. The clear_cal_data command clears all calibration data out of the CM database. This is required to override the preserve calibration feature, if enabled.
NOTE
6. 7.
Connect port COM1 on the PC to the TTY Interface port on the transceiver using the 9-way to 9-way EQCP/RSS cable. At the MMI-ROM prompt type: tcu_clock 0 The system responds with the following:
WARNING: CTU/CTU2 must be reset to get connection to MCU.
8.
If a tx antenna is not connected to the radio under test, connect a 50 ohm 50 W dummy load to the Tx port of the radio under test. CAUTION
Ensure that you have entered the tcu_clock 0 command at the RSS MMI-ROM 0000> prompt, as shown in step 7 before entering call processing to avoid EQCP instability at step 3 of Bay level calibration (next procedure).
9. 10.
Switch the 9-way to 9-way EQCP/RSS cable from providing RSS connectivity to providing EQCP connectivity. At the EQCP prompt type: .GSMFW TEST The system responds with the following:
WARNING: The EQCP is now in test mode.
11.
At the EQCP TEST prompt type: BBH ALARM OFF The system responds with the following:
The alarm reporting for the BBH connection is turned off
12.
At the EQCP TEST prompt type: AIC OUT The system responds with the following:
The AIC pad for branch 1 is OUT. The AIC pad for branch 2 is OUT.
68P02902W06-C006
Maint. 239
GSM
The antenna number can also be found by using the disp_equipment # DRI A * 0 command. The number next to antenna_select is the antenna number. 2. Set the signal generator to the first (lowest) test frequency for the correct frequency band under test and set the output level of the signal generator to 65 dBm. Table Maint. 2-6 to Table Maint. 2-9 list the test frequencies for GSM850, EGSM900, DCS1800 and PCS1900 frequency bands. 3. At the EQCP TEST prompt type: ACT C The system responds with the following:
The EQCP is in the Call Processing state Warning: After locking carrier down, enter CTU/CTU2_CLOCK 0 command at RSS MMI-ROM 0000> prompt before entering Call Processing to avoid EQCP instability.
4.
At the EQCP TEST prompt type: TS A ANT 1 The system responds with the following:
All timeslots are under user control.
5.
is:
the channel number of the selected frequency, as shown in the test frequency tables.
Maint. 240
29 Jan 2007
GSM
6.
At the EQCP TEST prompt type: SYNTH 1 The system responds with the following:
Synthesizer 1 is enabled.
7.
At the EQCP TEST prompt type: CAL BAY @1 The system responds with the following:
BAY LEVEL OFFSET = XX
Where XX = The hex value of the bay level reading. 8. At the EQCP TEST prompt type: SYNTH NRM The system responds with the following:
The system is under real time control.
9.
Set the signal generator to the next frequency and repeat steps 5 and 6 for all the test frequencies in the appropriate test frequency table.
68P02902W06-C006
Maint. 241
GSM
Channel
979 987 995 1003 1011 1019 03 11 19 27 35
Frequency (MHz)
881.001 882.601 884.201 885.801 887.401 889.001 890.601 892.201 893.801 895.401 897.001
Channel
43 51 59 67 75 83 91 99 107 115 123
Frequency (MHz)
898.601 900.201 901.801 903.401 905.001 906.601 908.201 909.801 911.401 913.001 914.601
Maint. 242
29 Jan 2007
GSM
Channel
516 524 532 540 548 556 564 572 580 588 596 604 612 620 628 636 644 652 660 668 676 684 692 700
Frequency (MHz)
1711.001 1712.601 1714.201 1715.801 1717.401 1719.001 1720.601 1722.201 1723.801 1725.401 1727.001 1728.601 1730.201 1731.801 1733.401 1735.001 1736.601 1738.201 1739.801 1741.401 1743.001 1744.601 1746.201 1747.801
Channel
708 716 724 732 740 748 756 764 772 780 788 796 804 812 820 828 836 844 852 860 868 876 883
Frequency (MHz)
1749.401 1751.001 1752.601 1754.201 1755.801 1757.401 1759.001 1760.601 1762.201 1763.801 1765.401 1767.001 1768.601 1770.201 1771.801 1773.401 1775.001 1776.601 1778.201 1779.801 1781.401 1783.001 1784.401
68P02902W06-C006
Maint. 243
GSM
Table Maint. 2-9 PCS1900 CTU test frequencies Channel 516 524 532 540 548 556 564 572 580 588 596 604 612 620 628 636 644 652 660 Frequency (MHz) 1851.001 1852.601 1854.201 1855.801 1857.401 1859.001 1860.601 1862.201 1863.801 1865.401 1867.001 1868.601 1870.201 1871.801 1873.401 1875.001 1876.601 1878.201 1879.801 Channel 668 676 684 692 700 708 716 724 732 740 748 756 764 772 780 788 796 804 Frequency (MHz) 1881.401 1883.001 1884.601 1886.201 1887.801 1889.401 1891.001 1892.601 1894.201 1895.801 1897.401 1899.001 1900.601 1902.201 1903.801 1905.401 1907.001 1908.601
Maint. 244
29 Jan 2007
GSM
3.
is:
the channel number of the selected frequency, as shown in the test frequency tables.
5.
At the EQCP TEST prompt type: SYNTH 1 CAL BAY @1 SYNTH NRM
6.
Set the signal generator to the next frequency and repeat steps 4 and 5 for all the test frequencies in the appropriate test frequency table.
68P02902W06-C006
Maint. 245
GSM
3.
is:
the channel number of the selected frequency, as shown in the test frequency tables.
5.
At the EQCP TEST prompt type: SYNTH 1 CAL BAY @1 SYNTH NRM
6.
Set the signal generator to the next frequency and repeat steps 4 and 5 for all the test frequencies in the appropriate test frequency table.
Maint. 246
29 Jan 2007
GSM
Continue the bay level calibration procedure for the branch 1 1800 antenna port as follows: 1. 2. Connect the output of the generator to RX1800 1A. Set the signal generator to provide 65.0 dBm at the antenna port and to the first channel test frequency shown in the appropriate test frequency table. At the EQCP TEST prompt type: TS A ANT 2 4. At the EQCP TEST prompt type: TS A CHAN # Where:
#
3.
is:
the channel number of the selected frequency, as shown in the test frequency tables.
5.
At the EQCP TEST prompt type: SYNTH 1 CAL BAY @1 SYNTH NRM
6.
Set the signal generator to the next frequency and repeat steps 4 and 5 for all the test frequencies in the appropriate test frequency table.
68P02902W06-C006
Maint. 247
GSM
Branch completion
To complete the bay level procedure for the branch, proceed as follows: 1. At the EQCP TEST prompt type: BAYDONE @1 The system responds with the following:
BAY LEVEL CALIBRATION IS DONE
2.
At the EQCP TEST prompt type: HALT C The system responds with the following:
The EQCP is in the Active Standby state
3.
At the EQCP TEST prompt type: WRENB The system responds with the following:
Device OK. Flash is now write enabled.
4.
At the EQCP TEST prompt type: SAVE CAL BAY The system responds with the following:
Save Cal Completed.
5.
At the EQCP TEST prompt type: WRPTC The system responds with the following:
Flash is now write protected.
Branch 2 procedure
Repeat the procedures Bay level calibration branch 1 RX0A, Bay level repeat for RX1A, Bay level repeat for RX2A and Bay level repeat for RX1800 1A for branch 2 by connecting to RX0B, RX1B, RX2B and RX1800 1B alternately. Enter @2 instead of @1 in the cal bay and baydone commands.
Maint. 248
29 Jan 2007
GSM
Table Maint. 2-10 lists the CTU frequency offset addresses for GSM850 frequencies.
Table Maint. 2-10 CTU frequency offset addresses (GSM850) Bay Level Calibration Storage Branch 1 Valid Flag Branch 2 Valid Flag Branch 1 Checksum Branch 2 Checksum Bay Level Offsets For Branch 1 Antenna 1 Bay Level Offsets For Branch 1 Antenna 2 Bay Level Offsets For Branch 1 Antenna 3 Bay Level Offsets For Branch 2 Antenna 1 Bay Level Offsets For Branch 2 Antenna 2 Bay Level Offsets For Branch 2 Antenna 3 Flash Address A000700 A000703 A000706 A000709 A00070C A00073B A00073C A00076B A00076D A00079B A00079C A0007CB A0007CC A0007FB A0007FC A00082B
GSM850 CTUs store offsets in 16 locations in each memory area per antenna per branch.
68P02902W06-C006
Maint. 249
GSM
Table Maint. 2-11 lists the CTU frequency offset addresses for EGSM900 frequencies.
Table Maint. 2-11 CTU frequency offset addresses (EGSM900) Bay Level Calibration Storage Branch 1 Valid Flag Branch 2 Valid Flag Branch 1 Checksum Branch 2 Checksum Bay Level Offsets For Branch 1 Antenna 1 Bay Level Offsets For Branch 1 Antenna 2 Bay Level Offsets For Branch 1 Antenna 3 Bay Level Offsets For Branch 2 Antenna 1 Bay Level Offsets For Branch 2 Antenna 2 Bay Level Offsets For Branch 2 Antenna 3 Flash Address A000700 A000703 A000706 A000709 A00070C A00074D A00074E A00078F A000790 A0007D1 A0007D2 A000813 A000814 A000855 A000856 A000897
EGSM900 CTUs store offsets in 22 locations in each memory area per antenna per branch. Table Maint. 2-12 lists the CTU frequency offset addresses for DCS1800 frequencies.
Table Maint. 2-12 CTU frequency offset addresses (DCS1800) Bay Level Calibration Storage Branch 1 Valid Flag Branch 2 Valid Flag Branch 1 Checksum Branch 2 Checksum Bay Level Offsets For Branch 1 Antenna 1 Bay Level Offsets For Branch 1 Antenna 2 Bay Level Offsets For Branch 1 Antenna 3 Bay Level Offsets For Branch 2 Antenna 1 Bay Level Offsets For Branch 2 Antenna 2 Bay Level Offsets For Branch 2 Antenna 3 Flash Address A000700 A000703 A000706 A000709 A00070C A000798 A000799 A000825 A000826 A0008B2 A0008B3 A00093F A000940 A0009CC A0009CD A000A59
DCS1800 CTUs store offsets in 47 locations in each memory area per antenna per branch.
Maint. 250
29 Jan 2007
GSM
Table Maint. 2-13 lists the CTU frequency offset addresses for PCS1900 frequencies.
Table Maint. 2-13 CTU frequency offset addresses (PCS1900) Bay Level Calibration Storage Branch 1 Valid Flag Branch 2 Valid Flag Branch 1 Checksum Branch 2 Checksum Bay Level Offsets For Branch 1 Antenna 1 Bay Level Offsets For Branch 1 Antenna 2 Bay Level Offsets For Branch 1 Antenna 3 Bay Level Offsets For Branch 2 Antenna 1 Bay Level Offsets For Branch 2 Antenna 2 Bay Level Offsets For Branch 2 Antenna 3 Flash Address A000700 A000703 A000706 A000709 A00070C A00077D A00077E A0007EF A0007F0 A000861 A000862 A0008D3 A0008D4 A000945 A000946 A0009B7
PCS1900 CTUs store offsets in 38 locations in each memory area per antenna per branch. NOTE
Each location consists of three bytes. For example, the branch 1 valid flag data is stored in address locations A000700, A000701 and A000702.
2.
The following is an example of the first line of the FLASH BAY LEVEL OFFSET table when using the FR BAY command, and a description of the fields displayed:
BR1 BR2 flag BR1 Cksum BR2 Cksum BL offse t BL offse t 000002 BL offse t 000005 BL offse t 000002
Addres s A000700
3.
If the bay level calibration is successful, each appropriate table location will contain valid offsets, and not the factory default of 80. NOTE
Any value from 81 to FF and 00 to 7F except 80 is a valid offset.
4.
The value 80 indicates an unsuccessful calibration procedure or an uncalibrated antenna port and will result in error alarm DRI 218: Invalid Transceiver Calibration Data being reported when the unit is unlocked. The calibration procedure will have to be repeated after checking the configuration and RF cables. NOTE
Unused data columns in a site configuration may have value 80. No alarm will be reported as such table locations are inappropriate to the site.
68P02902W06-C006
Maint. 251
GSM
Commands used
Table Maint. 2-5 lists the MMI commands that must be used to carry out the procedure: NOTE
The symbol 0 used in the commands in this procedure is a zero.
Table Maint. 2-14 MMI commands for CTU2 Rx bay level offset calibration
Function
Initializes the device, bringing it into service. Prevents the device being used. Frees the device for further use. Clears previously stored calibration data for a specified radio unit on a per DRI basis. Changes the DSP MMI security level. Puts the DSP fault management module in test mode. Blocks all DSP fault management alarms. Switches DSP MMI control to carrier A. Switches DSP MMI control to carrier B. Turns off Tx closed-loop power control for the current carrier. Configures which carriers will be calibrated by the Rx cabinet calibration procedure. Executes the Rx cabinet calibration procedure. Stores the calibration data. Sets the second carrier to Rx double density mode so that the calibration procedure is effective for both branches and both carriers.
Maint. 252
29 Jan 2007
GSM
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number of the transceiver.
For single density CTU2s the output will look similar to the following:
[05/02/03 14:42:37] MMIRAM 0115 > disp_eq 81 dri 0 0 DRI identifier: 0 0 DRI Density[dri_density]: SINGLE Cabinet identifier: 0 Type of connection to the BTP: MASTER Port to which the TCU is connected[tcu_port]: 0 RTF identifier[pref_rtf_id]: GSM cell ID where the DRI appears: 001 01 1 91 Antenna select number for this cell[antenna_select]: 1 Tuneable combining used: No The diversity flag for this DRI is[diversity_flag]: 0 The fm cell type is[fm_cell_type]: 0
For double density CTU2s the output will look similar to the following:
[05/02/03 14:47:55] MMIRAM 0115 > disp_eq 81 dri 0 1 DRI identifier: 0 1 DRI Density[dri_density]: DOUBLE Associated DRI identifier: 0 2 Cabinet identifier: 0 Type of connection to the BTP: MASTER Port to which the TCU is connected[tcu_port]: 1 RTF identifier[pref_rtf_id]: GSM cell ID where the DRI appears: 001 01 1 91 Antenna select number for this cell[antenna_select]: 1 Tuneable combining used: No The diversity flag for this DRI is[diversity_flag]: 0 The fm cell type is[fm_cell_type]: 0
In this case we see that DRI 0 1 is a double density CTU2 and is associated with DRI 0 2.
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 253
GSM
Thus, in this example, DRI 0 1 and DRI 0 2 are on the same CTU2. In the case of the single density CTU2, cabinet calibration will be performed once on the DRI. In the case of the double density CTU2, cabinet calibration is still performed on only one of the two DRIs, but the other DRI must be locked for the procedures to be carried out. Furthermore, the clear_cal_data commands must be issued for both DRIs.
Maint. 254
29 Jan 2007
GSM
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number of the transceiver. Always lock the transceiver providing the BCCH last as this prevents the BCCH being switched to alternate transceivers.
NOTE 4. 5.
If a Tx antenna is not connected to the transceiver under test, connect a 50 ohm 50 W dummy load to the Tx port. Unlock the CTU2 to be calibrated. Change to Level 3 and at the MMI-RAM> prompt type: ins_device # dri A * 0 Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number of the transceiver. In the case of a double density CTU2, Rx cabinet calibration only needs to be performed on one of the two DRIs. The other DRI must remain locked.
NOTE
6.
Connect a serial port on the PC to the TTY Interface port on the CTU2 to be calibrated using the 9-way to 9-way DSP MMI/RSS cable. If necessary, switch the 9-way to 9-way DSP MMI/RSS cable from providing RSS connectivity to providing DSP connectivity.
7.
At the DSP MMI prompt type: chglev and then enter the following password: pizza
8.
Enter calibration test mode and disable alarms by typing the following commands: cal_test_mode on fm test_mode on fm_test block none none 0xff
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 255
GSM
9.
If required, set the second carrier to Rx double density mode by typing the following command: ts a rx_br_sel 2 This enables the calibration procedure to take effect on both branches and both carriers.
10.
Turn the CTU2s transmitters off by typing the following at the DSP MMI prompt: set_carrier cara ts a txp 0xff set_carrier carb ts a txp 0xff set_carrier cara The response at the DSP MMI should be: CTU2.carA.ts_0>
11.
Configure which Rx antennas are to be calibrated using the following command: cal_config rx_cab_antennas <antenna> <antenna> <antenna> <antenna> <antenna> <antenna> Where <antenna> is one of the following: all All antennas. 0a Antenna 0A. 1a Antenna 1A. 2a Antenna 2A. 0b Antenna 0B. 1b Antenna 1B. 2b Antenna 2B. Up to six antenna options can be specified, separated by spaces. The option all is equivalent to 0A 1A 2A 0B 1B 2B. For example, to calibrate antennas 0A and 0B, type the following command: cal_config rx_cab_antennas 0a 0b The response will be:
Setting RX Cabinet Calibration antennas to: 0A 0B
To calibrate all antennas, type the following command: cal_config rx_cab_antennas all The response will be:
Setting RX Cabinet Calibration antennas to: ALL
Maint. 256
29 Jan 2007
GSM
12.
Start the Rx cabinet calibration procedure by typing the following command at the DSP MMI prompt: cal_cabinet rx_cab The following message will be displayed on the screen. This includes the SURF antenna connector to which the signal generator should be connected (shown in bold text).
cal_cabinet rx_cab Enabling receive [c A, b 0] Setting RX diversity switch to double density (inject carrier A into carrier B) Enabling transmit Number of frequency groups = 47 Please connect the signal generator to branch 0A Press return when the signal generator is connected. Press any key to continue
13.
When the signal generator is connected to the appropriate SURF antenna connector and configured, press ENTER at the DSP MMI prompt. The on-screen instructions will list the new signal generator settings required (shown in bold in the sample output below):
Please set the signal generator to POWER 65.2000 dBm FREQ 1710.8052 MHz Press any key to continue
Be sure to allow for any loss in the cables connecting the signal generator to the antenna connector. For example, if the cables have a loss of 1.5 dB and you are asked to provide 65.2 dBm, set the signal generator to 63.7 dBm. Make the appropriate adjustments and then press ENTER. The readings for each test frequency will look something like the following:
IQ average reading C0B0: 2565696, 0x00272640 IQ average reading C1B0: 2762909, 0x002a289d Measured gain: 14.76 (0x0ec2) Measured gain: 15.69 (0x0fb0) Frequency group 2 of 47 Please set the signal generator to POWER 65.2000 dBm FREQ 1712.4052 MHz Press any key to continue
14. 15.
Repeat the calibration procedure in step 13 for all the appropriate test frequencies (22 for EGSM and 47 for DCS1800). Once all frequencies have been calibrated, the program will request the signal generator is moved to the next SURF antenna connection (refer to example message in step 12). Repeat step 13 and step 14 for each antenna connection, until all frequencies on all antennas have been calibrated.
Maintenance and Parts: Horizonmacro indoor
16.
29 Jan 2007
68P02902W06-C006
Maint. 257
GSM
17.
Type the following command at the DSP MMI prompt when the calibration procedure has been completed: cal_store_1 After a few seconds delay (up to 16 seconds), the result of the data storage is displayed on the screen in the format:
cal_store_1 PASS CTU2.carA.ts_0>
18. 19.
Take the CTU2 out of test mode by entering the following command: fm test_mode off Connect to the BSC MMI and enter the following command to lock the CTU2 that has been calibrated: lock_device # dri A * 0 Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the transceiver.
20.
Clear the calibration data for both DRIs using the following command: clear_cal_data # dri A * 0 NOTE
The clear_cal_data command clears all calibration data out of the CM database. This is required to override the preserve calibration feature, if enabled.
21.
Move the 9-way to 9-way DSP MMI/RSS cable to the CTU2 TTY port of the next CTU2 to be calibrated and repeat the procedure from step 4.
Maint. 258
29 Jan 2007
GSM
Channel
978 986 994 1002 1010 1018 03 11 19 27 35
Frequency (MHz)
880.8052 882.4052 884.0052 885.6052 887.2052 888.8052 890.4052 892.0052 893.6052 895.2052 896.8052
Channel
43 51 59 67 75 83 91 99 107 115 123
Frequency (MHz)
898.4052 900.0052 901.6052 903.2052 904.8052 906.4052 908.0052 909.6052 911.2052 912.8052 914.4052
68P02902W06-C006
Maint. 259
GSM
Channel
515 523 531 539 547 555 563 571 579 587 595 603 611 619 627 635 643 651 659 667 675 683 691 699
Frequency (MHz)
1710.8052 1712.4052 1714.0052 1715.6052 1717.2052 1718.8052 1720.4052 1722.0052 1723.6052 1725.2052 1726.8052 1728.4052 1730.0052 1731.6052 1733.2052 1734.8052 1736.4052 1738.0052 1739.6052 1741.2052 1742.8052 1744.4052 1746.0052 1747.6052
Channel
707 715 723 731 739 747 755 763 771 779 787 795 803 811 819 827 835 843 851 859 867 875 883
Frequency (MHz)
1749.2052 1750.8052 1752.4052 1754.0052 1755.6052 1757.2052 1758.8052 1760.4052 1762.0052 1763.6052 1765.2052 1766.8052 1768.4052 1770.0052 1771.6052 1773.2052 1774.8052 1776.4052 1778.0052 1779.6052 1781.2052 1782.8052 1784.4052
Maint. 260
29 Jan 2007
GSM
Site restoration
After all the appropriate bay level calibration procedures are completed, restore the site by the following: 1. 2. 3. Remove the signal generator and dummy load and refit the site RF cables. Remove the 9-way to 9-way cable from the TTY interface port on the transceiver. Connect the 9-way to 9-way cable from the PC serial A port to an MCUF TTY port. CAUTION 4.
The following step must be carried out to initialize software and so ensure the transceiver is correctly brought into service.
Press the reset button on the front panel of the transceiver. If there is no reset button (some CTUs and all CTU2s), switch off the appropriate circuit breaker button on the CBM and then switch on again. Type unlock_device # dri A * 0 Where:
# A *
5.
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna.
The transceiver is now in the unlocked_busy state. 6. Type: disp_act_alarm # dri A * 0 Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna.
Confirm that there is no DRI 218 alarm. If there is a DRI 218 alarm, redo the whole bay level calibration procedure. 7. Remove the 9-way to 9-way cable from the MCUF TTY port.
68P02902W06-C006
Maint. 261
GSM
Figure Maint. 2-11 View of a later type single band SURF module
RX-Pn 2B RX-Pn 1B SIX N-TYPE RECEIVE ANTENNA CONNECTIONS (2 PER DLNB EQUIVALENT) RX-Pn 1A RX-Pn 0A
RX-Pn 0B RX-Pn 2A
NOTE
The dual band SURF replacement procedure is almost identical, with the addition of the extra two second frequency antenna connections.
Maint. 262
29 Jan 2007
GSM
Note the RF cable connections to the SURF module to enable correct reconnection to the replacement module. WARNING
Before disconnecting RF cables, ensure that RF power is OFF. If RF power is ON when cables are disconnected, severe burns may result.
2.
Disable all transceiver transmit RF power by using the shutdown_ device command at the OMC-R or from a PC connected to the MCUF. NOTE
Refer to Technical Description: BSS Command Reference 68P02901W23 for information on usage and specific device codes.
3. 4. 5. 6.
When all transceivers have been shutdown, check that the Tx STATUS LED (yellow) is unlit. Press and release the transceiver circuit breaker buttons on the CBM to the out (off) position. Ensure each RADIO STATUS LED is unlit. Press and release the SURF circuit breaker button on the CBM to the out (off) position. Disconnect the coaxial RF cables by carefully unscrewing and pulling them out of the module sockets. Note the positions for correct replacement. Using a torxdriver, unscrew the four M6 Torx captive screws holding the SURF module to the top of the cabinet. Using the handles, lift the SURF block from the slot.
7. 8.
68P02902W06-C006
Maint. 263
GSM
5. 6. 7.
8.
Maint. 264
29 Jan 2007
GSM
CAUTION
There are three slots for Tx blocks in the top panel basket of a cabinet, above the transceivers. There are four types of Tx block; DCF, TDF, DDF and HCU. Replacing a Tx block requires removal of RF transmitter power for the transceiver(s) that connect with the faulty Tx block. It is therefore advisable to perform this procedure during periods of low traffic. The OMC-R should be notified of imminent repair activity. If a stacking bracket is fitted, the CCB basket has to be removed in order to gain access to the Tx block modules (see Replacing a CCB). It is important to ensure that all unused Tx Block M6 screw locations have a screw in place and tightened to correct torque (see Overview of replacement procedures ). This is to ensure maximum quality of EMC and general containment.
68P02902W06-C006
Maint. 265
GSM
ISOMETRIC VIEW
SMA Tx CONNECTORS FROM TRANSCEIVERS
SIDE VIEW
Maint. 266
29 Jan 2007
GSM
Replacing a Tx block
Removing a faulty Tx block
To remove a Tx block, proceed as follows: 1. Locate the faulty Tx block, and note the RF cable connections to enable correct reconnection to the replacement module. WARNING
Ensure that all transceivers associated with the faulty Tx block are identified (for example inputs to an HCU or feedthrough plate connected to a DDF).
2.
Identify the transceivers that make Tx connections to the underside of the faulty Tx block (plus any transceivers connected to the third Tx connector on top of a DDF). See Table Maint. 2-17.
Table Maint. 2-17 Connectors for each type of Tx block module Tx block SMA from transceiver TX 7/16 Rx/Tx to antenna N-type Rx to SURF
1 2
1 2
1 0
1 1 to next Tx block
Disable each transceiver transmit RF power by using the shutdown_ device command at the OMC-R or from a PC connected to the MCUF. Refer to Technical Description: BSS Command Reference 68P02901W23 for information on usage and specific device codes. When each transceiver has been shutdown, check that the Tx status LED (yellow) is extinguished. Press and release each transceiver circuit breaker button on the CBM to the out (off) position. Ensure each RADIO STATUS LED is extinguished. WARNING
Ensure that RF power is OFF, before disconnecting RF cables. Severe burns may result if RF power is ON when RF cables are disconnected.
4. 5.
6. 7.
Disconnect all coaxial RF cables by carefully unscrewing and pulling them out of the Tx block sockets. Note the positions for correct replacement. Using a Torx driver, unscrew and retain the two M6 Torx screws holding the Tx block to the top of the cabinet. WARNING
Tx blocks can weigh as much as 5 kg. Handle with care.
8.
68P02902W06-C006
Maint. 267
GSM
1. 2.
Transfer the protective caps on the RF connectors from the replacement Tx block to the faulty Tx block. Carefully insert the replacement Tx block into its basket location on the top panel, adjusting alignment for retaining screws. Take care to avoid trapping cables as the Tx block is seated. Fit the two M6 torx screws to hold the Tx block to the top of the cabinet. Tighten to correct torque (see Overview of replacement procedures). Reconnect the coaxial RF cables to the positions noted in the removal procedure. Tighten to correct torque (see Overview of replacement procedures ). NOTE
Ensure all unused SMA inputs to DCF, DDF and HCU modules are fitted with 50 ohm load terminations.
3. 4.
5.
Reset the appropriate transceiver circuit breaker buttons on the CBM. Each RADIO STATUS LED will flash green for about two minutes, and then remain lit. Enable the transceiver transmit RF power by using the ins_device command at the OMC-R or from a PC connected to the MCUF. The Tx STATUS LED (yellow) will be lit if the transceiver is transmitting. Notify the OMC-R of base station availability and log the maintenance activity.
6.
7.
Maint. 268
29 Jan 2007
GSM
Replacing a CCB
Replacing a CCB
Overview of CCB replacement
CCBs, or their associated CCB control boards, can be individually replaced. It is assumed that the OMC-R has identified which item requires replacement. CCB block 0 is the right most block looking from the front, as shown in Figure Maint. 2-13, and is the main CCB, with master CCB control board. CCB block 1 is the extension CCB, with an optional redundant CCB control board. The replacement of CCBs can only take place after the cabinet has been taken out of service, in agreement with the OMC-R.
Figure Maint. 2-13 CCBs in installed position with CCB basket bar attached
CCB0
CCB1
CCB BASKET BAR CAPTIVE SCREWS ON CCB BASKET CAPTIVE SCREW ON BAR
ig.336.rh
68P02902W06-C006
Maint. 269
Replacing a CCB
GSM
Removing the CCB basket from the stacking bracket. Separating CCBs from CCB basket.
3.
Loosen the three captive screws attaching CCB basket bar to basket and the two captive screws securing CCB basket bar to the sides of the stacking bracket. Remove the bar. Disconnect the six N-type to N-type RF cables from the CCB inputs, and leave draped over the front of the cabinet. Note the locations for correct replacement. Slide basket part way out of the stacking bracket, and disconnect antennas to CCBs. Remove the CCB basket, complete with CCBs, from stacking bracket.
5.
6. 7.
The CCBs have now been removed, ready for replacement CCBs.
Maint. 270
29 Jan 2007
GSM
Replacing a CCB
3. 4.
6. 7. 8.
The CCBs are now replaced and ready for power up of the cabinet.
68P02902W06-C006
Maint. 271
GSM
A faulty master MCUF, FMUX or BPSM will cause a redundant module (if fitted) to take over until the faulty module is replaced. Faulty MCUF, FMUX and BPSM modules can be hot swapped without harm to the module or effect on normal operation, provided the equivalent redundant module has taken over. Removal of a faulty digital module that has not had its function taken over by a redundant module, and is still partially functional, will affect service. Inform the OMC-R before replacing out such modules.
Figure Maint. 2-14 Digital and BPSM module locations including optional redundancy
DIGITAL MODULE SHELF
FMUX NIU B0 NIU B1 BPSM
MCUF B
ALARM MODULE
REDUNDANT (B)
MASTER (A)
ig.322.rh
Maint. 272
29 Jan 2007
GSM
CAUTION
1. 2. 3.
If the faulty digital module is still partially functional, due to no redundancy option, inform the OMC-R before proceeding. Locate the faulty module, as shown in Figure Maint. 2-14. Note location of any fibre optic cable connections to the module, (MCUF or FMUX modules only), to enable correct reconnection to the replacement module. Disconnect each fibre optic cable by gently pushing the knurled connector in and rotating it through a quarter-turn anticlockwise to disengage, then withdraw the cable carefully. NOTE
It is advisable to protect the tips of the fibre optic cables with a protective cover and secure the cables to one side.
4.
5.
Unseat the module by gripping the upper and lower pair of ejectors between the thumb and first finger of each hand, then gently squeeze and pull on the ejectors until the module unclips at the top and bottom of the front panel and unplugs from the rear connector. Carefully slide the module from its location and place it in an anti-static storage container.
6.
68P02902W06-C006
Maint. 273
GSM
NOTE
5. 6.
When fitting a redundant MCUF refer to Redundant MCUF firmware compatibility for details of further checks required. Notify the OMC-R of base station availability and log the maintenance activity.
Maint. 274
29 Jan 2007
GSM
or,
BTP 0 0 0 BTP 1 0 0 BU DU NO REASON No Redundant Link
If No Redundant Link is indicated then the master MCUF is not in communication with the redundant MCUF and firmware incompatibility may be assumed. Refer to Updating redundant MCUF firmware.
68P02902W06-C006
Maint. 275
GSM
Site preparation
To prepare for the firmware update the site must first be taken out-of-service as follows: 1. 2. Connect a PC to the TTY connection on the master MCUF. At the CUST MMI prompt, disable all transceivers in turn by typing shutdown_device <site #> dri * * * <seconds> Where <site #> * ** <seconds> 3. 4. is the site number the DRI identifier the time delay before shutdown occurs
Confirm this action by observing each transceiver Tx status LED, which should extinguish shortly after issuing the shutdown command. Disconnect the 2.048 Mbit/s link.
The MCUF firmware update is complete and both MCUFs now hold identical firmware. The MCUF originally removed from the master position may now be used in the redundant position.
Maintenance and Parts: Horizonmacro indoor 68P02902W06-C006
Maint. 276
29 Jan 2007
GSM
6.
Insert the original master MCUF into the redundant position. The redundant MCUF now requires a 15 minute sync warm up period, followed by a further delay of four minutes while the two MCUFs achieve phase lock. Once phase lock is achieved the master MCUF immediately begins codeloading to the redundant MCUF. Codeloading takes a further 15 minutes. The process is complete when the following message is displayed on screen:
Redundant MSW is INS <*><*><*> NEW STANDBY Switch CONFIGURED <*><*><*>
7.
To confirm correct MCUF status, at the CUST MMI prompt, enter: state <site #> btp * * Where <site #> is the site number. The status of both BTPs will be displayed as follows:
BTP 0 0 0 BTP 1 0 0 BU EU NO REASON NO REASON
Where
BU E-U
8.
68P02902W06-C006
Maint. 277
GSM
Connect a PC to the TTY connection on the master MCUF. At the CUST MMI prompt, type state <site #> btp * * Where <site #> is the site number. The status of both BTPs will be displayed as follows:
BTP 0 0 0 BTP 1 0 0 BU EU NO REASON NO REASON
Where
BU E-U
3.
At the CUST MMI prompt, type swap_devices <site #> btp 0 0 0 btp 1 0 0 Where
<site #> btp 0 0 0 btp 1 0 0
the redundant MCUF into a busy state , and making it master. the master MCUF into an enabled state, and making it redundant.
4.
At the CUST MMI prompt, confirm the swap by typing: state <site #> btp * * Where <site #> is the site number. The status of both BTPs will now show changed roles:
BTP 0 0 0 BTP 1 0 0 EU BU NO REASON NO REASON
5. 6.
Make test calls on the site to verify the new master MCUF. At the CUST MMI prompt type, swap the MCUFs back to their original states by typing: swap_devices <site #> btp 1 0 0 btp 0 0 0 Where
<site #> btp 1 0 0 btp 0 0 0
Maint. 278
29 Jan 2007
GSM
7.
At the CUST MMI prompt, confirm the swap by typing: state <site #> btp * * Where <site #> is the site number. Both BTPs have now reverted to their original roles:
BTP 0 0 0 BTP 1 0 0 BU EU NO REASON NO REASON
8.
Make test calls on the site to verify the new master MCUF.
68P02902W06-C006
Maint. 279
GSM
This procedure explains how to calibrate the Ovenized Crystal Oscillator (OCXO) in the MCUF GCLK in the Horizonmacro product at a BSS site.
When more than one frame slip per hour is observed at the OMC-R (typically more than 34/day). Whenever calibration is required. (Display the active alarms for a site - if calibration is required, there will be an alarm stating this). CAUTION
This procedure should only be carried out by fully trained, GSM qualified personnel. Under NO circumstances should this procedure be undertaken, unless all the correct test equipment is readily available. The command gclk_cal_mode used in this procedure should only be executed at the BTS where the calibration is being carried out. No call processing can occur involving the MCUF during calibration mode. Allow a period of 15 minutes to elapse after switching the OCXO power on, to give sufficient time for the unit to reach operating temperature and achieve frequency stabilization.
NOTE
An IBM compatible personal computer (PC). A 9-way to 9-way TTY cable. A caesium or rubidium clock standard with 1 or 10 MHz output frequency. A Universal counter with external reference, for example, the Hewlett Packard model HP5385A or equivalent. A BNC to 3-way MCUF test lead, part number 3086144E01.
Maint. 280
29 Jan 2007
GSM
MCUF TTY
8000.000000
10 MHz REFERENCE UNIVERSAL COUNTER
68P02902W06-C006
Maint. 281
GSM
When the command is executed the system will prompt for verification:
Site <Local site number> starting GCLK CALIBRATION MODE. If this is a single MCU site, the site will be down until calibration is complete. Are you sure (y=yes, n=no)?
Enter y The MCUF will begin calibration mode. The command is aborted if the reply is anything other than y. 4. The following prompt will appear:
Frequency Counter Connected, Enter y when ready, or a to abort test.
Enter y The command is aborted and calibration mode exited if the reply is anything other than y.
Maint. 282
29 Jan 2007
GSM
5.
Adjust the OCXO control voltage using the +/ and 0 to 3 keys until the measured frequency is exactly 8000,000000 Hz. The values entered here, change the frequency by varying degrees. For example: +0 will increase the output by a small amount. +1 will increase the frequency by approximately 10 times. +2 will increase the frequency by approximately 100 times. +3 will increase the frequency by approximately 1000 times.
These are not exact values as every OCXO has a different gain. This method gives sufficient control to correct the frequency within a short time. A typical sequence of numbers may look as follows:
Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >3 (7.99999898) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >+3 (8.00000020) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >0 (8.00000019 - 8.00000020) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >2 (8.00000004) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >+2 (8.00000020) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >1 (8.00000018) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >2 (8.00000002 -8.00000003) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >1 (8.000000--) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >+0 (8.000000-) Enter a to abort. s to save, +(0..3) to inc, (0..3) to dec >+0 (8.00000000)
6.
Enter s
CAL OFFSET is 23654 DAC bits.
After calibration, the MCUF applies a set of voltages to the DAC that feeds the OCXO, requiring the user to input the corresponding output frequency. This is necessary because the OCXO frequency/voltage characteristic is not linear and the MCUF adjusts for this by taking readings across a range of DAC voltages.
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 283
GSM
7.
To calibrate the OCXO, gain, enter the measured frequency value from the counter after the value has settled in response to the MMI prompts. NOTE
When taking frequency measurements, ensure that a full gate period elapses from the time the new value is set to reading the counter. This wait may be several seconds depending on the counter.
NOTE 8.
On completion, the MCUF will automatically reject the calibration if it is outside the threshold and the following message will be displayed:
Computed Gain > Max WILL RETRY GAIN
Calibration must be performed again. If calibration fails the second time with the same or similar value, the OCXO may be operating outside the Motorola specification, in which case the MCUF is deemed faulty and should be replaced.
Maint. 284
29 Jan 2007
GSM
68P02902W06-C006
Maint. 285
Chapter 3
68P02902W06-C006
Maint. 31
GSM
Maint. 32
29 Jan 2007
GSM
Introduction
Checking the antenna VSWR and calibrating the transmit output power. Checking the database equipage. Checking the E1/T1 link. Checking the PIX connections and alarm test.
68P02902W06-C006
Maint. 33
GSM
Description PC
Comments To have a serial comms port for sending or configuring messages to the BSC and/or BTS. Up to 2 GHz. PC PLUS or similar software. Hewlett Packard E2378A or equivalent. 100 W minimum. RTLXQ98088 or equivalent.
1
1 1 1 1 2 1 1
Signal generator Commercial terminal emulator software Digital multimeter 30dB attenuator RF adapter kit N to 7/16 inch adapter N to N barrel adapter
RF wattmeter with 5 W, 10 W, 25 W and 50 W elements Digital RF wattmeter with wideband power sensor
For measuring average power on the calibration channel, use a Bird model 43 wattmeter or equivalent. For measuring TX power on a BCCH/TCH channel, use a meter capable of measuring burst average power.
Must be calibrated. Must be calibrated. Compatible with PC to TTY port on transceiver/MCUF. EQCP/RSS cable (CTU) or DSP MMI/RSS cable (CTU2), connecting PC to transceiver TTY port. See Note below.
1 1
2 metres of N to N male coaxial cable 4 metres of N to N male coaxial cable 9-way to 9-way cable 9-way to 9-way cable (transceiver only)
2 1
Maint. 34
29 Jan 2007
GSM
NOTE
The EQCP/RSS cable (for CTU) and DSP MMI/RSS cable (for CTU2) are actually the same cable, it is only the nomenclature that is different.
68P02902W06-C006
Maint. 35
GSM
NOTE
TCU-B test lead 3086240N01 may alternatively be used instead of transceiver test lead 3086299N01, but adapter (58C86540N01) is required to attach the 25-way cable connector to the 9-way transceiver port.
20 21 22 23 24 25 26 27 n/a 29
When making the PIX test lead: Normally open (N/O) PIX inputs should be connected through a 50 ohm resistor. Normally closed (N/C) PIX inputs should be connected through a 50 kohm resistor. Details of N/O and N/C site inputs can be found in the equip_eas file in the site commissioning database.
Maint. 36
29 Jan 2007
GSM
The objective of the VSWR check and output power calibration procedure is to ensure that antenna feeders and connectors are properly terminated and then set the pre-defined maximum transmitter output power at the top of the cabinet. When a transceiver is manufactured, it undergoes comprehensive transmit and receive calibration procedures. These procedures aim to produce a transceiver that exhibits a flat frequency response over the GSM band. In the case of the transmitter, this is performed by distributing the channels over three detector groups (the detector being the device that maintains a steady output power level). In the field, the procedure for setting the transmit output power involves using a set of commands called Cell Site Power (CSPWR). During CSPWR the user can trim the cabinet output power to account for any abnormalities that may occur between the transceiver and the top of the cabinet. The offset is effectively subtracted from the requested power level, such that for whatever channel is selected, a steady output is maintained at the top of the cabinet. There are three sets of procedures available for checking VSWR and cell site power:
S S S
Normal CTU VSWR and cell site power calibration. Normal CTU2 cell site power calibration. CTU VSWR and cell site power calibration for CCBs. NOTE
The procedure CTU VSWR and cell site power calibration for CCBs does not apply to GSM850 and PCS1900 CTUs or any CTU2s.
The appropriate Preparing for test procedure at the end of this section should be completed before attempting the VSWR and cell site power calibration procedures.
68P02902W06-C006
Maint. 37
GSM
An IBM-compatible personal computer (PC). Terminal emulator software. A Bird model 43P (Thru-line) wattmeter, or equivalent, with 5 W and 50 W elements. A 9-way to 9-way cable (a diagram of this cable is provided in the Test equipment, leads and plugs section). A 9-way to 9-way EQCP/RSS (CTU) or DSP MMI/RSS (CTU2) cable. NOTE
These cables are the same, only the nomenclature is different.
S S
Maint. 38
29 Jan 2007
GSM
Commands used
The command set used depends on the type of transceiver being calibrated.
CTU commands
Table Maint. 3-3 lists the commands for the CTU VSWR and output power calibration procedure.
Table Maint. 3-3 CTU VSWR and power calibration commands BSS MMI Command Function Initializes the device, bringing it into service. Prevents the device being used. Frees the device for further use. Clears previously stored calibration data for a specified radio unit on a per DRI basis. Function Stops the CTU hunting between link A and link B and forces the CTU to look only at link A. Function Places the CTU in test mode. Activates the control processor. Inhibits the BBH alarm. Cell site power. Allows the cell site power to be set to the maximum output power. Stops the control processor.
tcu_clock 0
CTU Command Emulator
XXX
TS <T> TXPWR <nn> U and D ESC (key)or CTRL-Y or CTRL-C WRENB SAVE CAL TX WRPTC FR TX MR TX SNDCMB NOTE
Timeslot set up. Where: <T> = Timeslot no. or A = ALL XXX = ARFCN to tune timeslot to. nn = Attenuation level from max. Used with the CSPWR command to increase (U) or decrease (D) the power level by a factor of 0.2 dB. Used to exit the CSPWR command and store the resulting offset to RAM. Write enables the FLASH EPROM. Used to store the resulting offset in FLASH EPROM. Write protects the FLASH EPROM. Reads Tx offset for FLASH EPROM. Reads Tx offset for RAM. Emulates combiner control processor messaging.
1. The symbol 0 used in the commands is a zero. 2. BSS MMI commands may be entered in upper or lower case. All other commands must be entered in the case shown.
68P02902W06-C006
Maint. 39
GSM
CTU2 commands
Table Maint. 3-4 lists the commands for the CTU2 output power calibration procedure. NOTE
The symbol 0 used in the commands is a zero. Table Maint. 3-4 CTU2 power calibration commands BSS MMI Command Function Initializes the device, bringing it into service. Prevents the device being used. Frees the device for further use. Clears previously stored calibration data for a specified transceiver on a per DRI basis. Changes the DSP MMI security level. Initiates Tx calibration test mode. Puts the DSP fault management module in test mode. Blocks all DSP fault management alarms. Set Tx power calibration mode for single or double density. <single> is the default mode and may be omitted. Set Tx power calibration to calibrate the first carrier only or both carriers when in double density mode. <carriera> is the default and may be omitted. Perform Tx power calibration. Stores the calibration data.
fm test_mode on
fm_test block none none 0xff
cal_config tx_cab_mode <single> / <double> cal_config tx_cab_carriers <carriera> / <both> cal_cabinet tx_cab cal_store_1
Test stages
There are four stages to the procedure:
S S S S
Preparing for test. Checking the VSWR (CTU only). Calibrating the transmit output power. Restoring the site. NOTE
VSWR checks ensure correct antenna matching and can prove the serviceability of the antenna. Repeat the procedures for all antennas on site, including receive antennas.
Maint. 310
29 Jan 2007
GSM
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna. The CTU must be brought into service as there is no flash EPROM storage of code at the radio control processor level. If a connection to the BSC is not available a PCMCIA commissioning card must be used.
NOTE
5.
Wait for the transceiver to finish initializing, then lock the DRI using the lock device command. WARNING
An RF hazard exists during DRI transmissions. As one antenna may be connected to a number of DRIs, the lock command must be repeated for all DRIs on the antenna being worked on before connecting the wattmeter.
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna. For ease of calibration, all transceivers in a cell should be initialized and then locked. Always lock the transceiver providing the BCCH last, as this prevents the BCCH being switched to alternate transceivers.
NOTE
68P02902W06-C006
Maint. 311
GSM
6.
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna. The clear_cal_data command clears all calibration data out of the CM database. This is required to override the preserve calibration feature, if enabled.
NOTE
7. 8.
Connect port COM1 on the PC to the TTY Interface port on the transceiver using the 9-way to 9-way RSS cable. At the MMI-ROM prompt, type tcu_clock 0 The system will respond with the following:
WARNING: TCU must be reset to get connection to MCU.
NOTE
Do not reset the CTU at this time. The reset is carried out on completion of the transceiver VSWR and cell site power calibration procedure, as described in Site restoration.
9.
Remove the 9-way to 9-way RSS cable from the transceiver and replace it with the 9-way to 9-way EQCP cable.
Maint. 312
29 Jan 2007
GSM
A CTU2 may consist of one or two DRIs. If a CTU2 is configured for double density mode (two DRIs), Tx cabinet calibration need only be performed on one of the DRIs because the same cabinet calibration data will be used by both DRIs. The following will help determine whether a CTU2 is configured as single or double density transceiver and which DRI numbers correspond to which CTU2s. At the BSC TTY, change to Level 3 and at the MMI-RAM> prompt type the following: disp_eq # dri A * 0 Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number of the transceiver.
For single density CTU2s the output will look similar to the following:
[05/02/03 14:42:37] MMIRAM 0115 > disp_eq 81 dri 0 0 DRI identifier: 0 0 DRI Density[dri_density]: SINGLE Cabinet identifier: 0 Type of connection to the BTP: MASTER Port to which the TCU is connected[tcu_port]: 0 RTF identifier[pref_rtf_id]: GSM cell ID where the DRI appears: 001 01 1 91 Antenna select number for this cell[antenna_select]: 1 Tuneable combining used: No The diversity flag for this DRI is[diversity_flag]: 0 The fm cell type is[fm_cell_type]: 0
For double density CTU2s the output will look similar to the following:
[05/02/03 14:47:55] MMIRAM 0115 > disp_eq 81 dri 0 1 DRI identifier: 0 1 DRI Density[dri_density]: DOUBLE Associated DRI identifier: 0 2 Cabinet identifier: 0 Type of connection to the BTP: MASTER Port to which the TCU is connected[tcu_port]: 1 RTF identifier[pref_rtf_id]: GSM cell ID where the DRI appears: 001 01 1 91 Antenna select number for this cell[antenna_select]: 1 Tuneable combining used: No The diversity flag for this DRI is[diversity_flag]: 0 The fm cell type is[fm_cell_type]: 0
In this case we see that DRI 0 1 is a double density CTU2 and is associated with DRI 0 2.
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 313
GSM
Thus, in this example, DRI 0 1 and DRI 0 2 are on the same CTU2. In the case of the single density CTU2, cabinet calibration will be performed once on the DRI. In the case of the double density CTU2, cabinet calibration is still performed on only one of the two DRIs, but the other DRI must be locked for the procedures to be carried out. Furthermore, the clear_cal_data commands must be issued for both DRIs.
Maint. 314
29 Jan 2007
GSM
Two methods available for normal VSWR checking are described in this section; one automatic and one manual. The reason for the two methods is as follows:
Prior to executing the CSPWR command, it assumes that the synthesizers are in normal mode (not locked), as is the case after the unit is powered up for the first time.
68P02902W06-C006
Maint. 315
GSM
CAUTION
The following procedure automatically checks the VSWR of the transmission path: 1. 2. Disconnect antenna. Connect a dummy load to the meter, ensuring the meter is fitted with a 50 W element and connect the meter to the Tx output. At the EQCP prompt type: .GSMFW TEST ACT C BBH ALARM OFF CSPWR 3. 4. 5. 6. 7. 8. Monitor and record the wattmeter reading (the forward output power). Press ESC or CTRL-Y or CTRL-C. Replace the 50 W element in the wattmeter with a 5 W element and reverse the direction on the power meter. Remove the dummy load and connect the power meter through to the antenna. At the EQCP TEST prompt, type CSPWR Monitor and record the reverse power reading indicated on the power meter. NOTE
Readings should show reflected (reverse) power of no more than 5% of the forward power at the point of measurement, and less than 1 W. If the ratio of the forward and reverse readings is unacceptable, suspect an improper termination of the antenna feeder and connector.
9. 10.
Press ESC or CTRL-Y or CTRL-C. At the EQCP TEST prompt, type HALT C
11.
Maint. 316
29 Jan 2007
GSM
2.
is:
all timeslots (TS). the specified channel number.
4.
To switch the power on, enter the following command: TS A TXPWR 00 Where:
A 00
is:
all timeslots (TS). maximum output power.
5. 6.
Monitor and record the wattmeter reading (the forward output power). To switch the power off, enter the following command: TS A TXPWR FF Where:
A FF
is:
all timeslots (TS). zero output power.
68P02902W06-C006
Maint. 317
GSM
CAUTION
The following procedure is used to manually check the VSWR reverse power: 1. 2. 3. 4. Replace the 50 W element in the wattmeter with a 5 W element and reverse the direction on the power meter. Remove the dummy load and connect the power meter through to the antenna. To switch the power on, enter TS A TXPWR 00 Monitor and record the reverse power reading indicated on the power meter. NOTE
Readings should show reflected (reverse) power of no more than 5% of the forward power at the point of measurement, and less than 1 W. If the ratio of the forward and reverse readings is unacceptable, suspect an improper termination of the antenna feeder and connector.
5. 6. 7. 8.
To switch the power off, enter TS A TXPWR FF Repeat the forward and reverse power checks for the required number of channels. At the EQCP TEST prompt, type HALT C Remove the power meter and reconnect the antenna.
Maint. 318
29 Jan 2007
GSM
The following procedure is used to calibrate CTU transmit output power: 1. Disconnect the antenna. Connect a dummy load/attenuator/coupler to the power meter, ensuring the meter is fitted with a 100 W element. Connect the meter to the Tx output, ensuring you have sufficient attenuation as to protect the power meter/sensor from damage. NOTE
Ensure that the digital power wattmeter has been correctly set up. Refer to the manufacturers manual for detailed instructions on how to carry out the following: S Perform selfcalibration of power meter with sensor.
S S 2.
Enter cable offset (Cable loss) into power meter to display the correct output power. Enable burst averaging or Burst Average Power.
At the EQCP prompt type: .GSMFW TEST ACT C BBH ALARM OFF
3.
4.
Enter U or D to adjust the CTU Tx power to achieve the appropriate value, as detailed in Table Maint. 3-5:
Table Maint. 3-5 Achievable Tx RF power output RF configuration CTU 900/850 CTU 1800 CTU 1900
Or the customer-specified value at the top of the cabinet, taking cable losses into account.
As U or D is typed, a message similar to the following example, indicating the CTU output power and offset value, is displayed:
D P: 46.8 dBm Cell Site Offset: 1
When the required output level is achieved, press ESC or CTRL-Y or CTRL-C.
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 319
GSM
6.
At the EQCP TEST prompt type: HALT C WRENB SAVE CAL TX WRPTC NOTE
The cell site offset can be checked by reading the memory location:
S S 7. 8. 9.
Repeat steps 1 to 6 until all transceivers have been calibrated. Remove the power meter and reconnect the antenna. Use the Site restoration procedure to return the site to service.
Maint. 320
29 Jan 2007
GSM
B.
In some configurations a newly installed CTU2 may power up in a Horizonmacro indoor cabinet in the following state:
Device DRI 1 1 0 DRI 1 2 0 State DU DU Reason Cell Tx Pwr Unachievable Cell Tx Pwr Unachievable Last Transition dd/mm hh:mm:ss 19/08 11:10:03 19/08 11:10:28 Related Function None None
In such cases the max_tx_bts parameter for that cell should be changed to at least 4. The transceivers will then come into service and the CTU2 Tx output power calibration procedure described below can be performed. Proceed as follows to calibrate CTU2 transmit output power: 1. 2. 3. Connect the 9-way to 9-way MCUF cable from the PC serial A port to the MCUF TTY port. At the PC, start the terminal emulator program. Lock all DRIs in the sector. At the MCUF TTY, change to Level 3 and at the MMIRAM> prompt type: lock_device # dri A * 0 Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number of the transceiver. Always lock the transceiver providing the BCCH last as this prevents the BCCH being switched to alternate transceivers.
NOTE
68P02902W06-C006
Maint. 321
GSM
4.
Disconnect the antenna. Connect a dummy load to the power meter, ensuring the meter is fitted with a 50 W element. Connect the meter to the Tx output. Change to Level 3 and at the MMIRAM> prompt, type ins_device # dri A * 0 Where:
# A *
5.
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number of the transceiver.
6.
Connect a serial port on the PC to the TTY Interface port on the CTU2 to be calibrated using the 9way to 9way DSP MMI/RSS cable. If necessary, switch the 9way to 9way DSP MMI/RSS cable from providing RSS connectivity to providing DSP connectivity.
7.
At the DSP MMI prompt, type chglev and then enter the following password: pizza
8.
Enter calibration test mode and disable alarms by typing the following commands: cal_test_mode on fm test_mode on fm_test block none none 0xff
9.
By default, Tx calibration is performed in the mode specified in the database. To force Tx calibration in either single or double density mode for a transceiver, enter one of the following commands as required: cal_config tx_cab_mode single cal_config tx_cab_mode double To reset Tx calibration to the mode specified in the database, enter the following command: cal_config tx_cab_mode database
10.
OPTIONAL STEP TO CALIBRATE CARRIER B. This step is only applicable if calibrating in double density mode (see step 9). By default, only the first carrier (Carrier A) is calibrated. To calibrate the second carrier (Carrier B) additionally, specify that both carriers are to be calibrated with the following command: cal_config tx_cab_carriers both
Maintenance and Parts: Horizonmacro indoor 68P02902W06-C006
Maint. 322
29 Jan 2007
GSM
NOTE
Both carriers have approximately the same output power. Due to variations in the hardware and factory calibration, small differences can occur. To finetune the calibration so that both carriers can achieve the same power, specify that both carriers should be calibrated by entering the above command.
To reset Tx calibration to only calibrate Carrier A, enter the following command: cal_config tx_cab_carriers carriera 11. Start the Tx cabinet calibration procedure by typing the following command at the DSP MMI prompt: cal_cabinet tx_cab The following warning message will be displayed on the screen:
WARNING! All attenuation is about to be removed. Please ensure that appropriate attenuation is attached to the CTU2 TX output. Press any key to continue
12. 13.
Check the connections to the antenna and then press ENTER. Press U to increase output power or D to decrease output power until the reading on the power meter matches the target maximum power for the sector. As the output power is adjusted, a message similar to the following will be displayed:
Setting offset to = 0x14 (4.0dB)
In configurations where the maximum output power of the CTU2 falls below that of a CTU, the initial offset is not 0x00. The initial CTU2 offsets shown in Table Maint. 3-6 below are based on the difference in maximum Tx power between CTU and CTU2 transceivers in the specified configuration.
Table Maint. 3-6 CTU2 Tx power offsets RF band EGSM900 EGSM900 DCS1800 DCS1800 Mode Single density Double density Single density Double density Initial offset 0x04 (0.8 dB) 0x10 (3.2 dB) 0x00 (0.0 dB) 0x0a (2.0 dB)
14.
An offset less than this initial value may be specified by pressing U when the transceiver is already at maximum power. Doing so will not change the maximum output power, but it will allow the CTU2 to be aligned with existing CTUs in the same cell that have not been recalibrated. After pressing U, follow the on-screen instructions to enter the measured and target powers; the target should be the same as that used when the CTUs in the cell were calibrated. Examples of methods of entering Tx power values are given at the end of this procedure.
Maintenance and Parts: Horizonmacro indoor
15.
29 Jan 2007
68P02902W06-C006
Maint. 323
GSM
NOTE
In some configurations with CTU2s in a Horizonmacro cabinet, the cells maximum transmit power (cell element max_tx_bts ) must be decreased to allow the CTU2s to come into service.
16. 17.
Press Q when the desired output power level has been reached. If Carrier B was configured to be calibrated in Step 10, then follow the on screen directions to repeat Steps 12 to 16 for Carrier B. Otherwise, proceed to the next step. Store the new Tx cabinet calibration using the following DSP MMI command: cal_store_1 After a few seconds delay (up to 16 seconds), the result of the data storage is displayed on the screen in the format:
cal_store_1 PASS CTU2.carA.ts_0>
18.
19.
After the data has been stored, connect the 9-way to 9-way MCUF cable from the PC serial A port to the MCUF MMI TTY port and enter the following command to lock the CTU2 that has been calibrated: lock_device # dri A * 0 Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the transceiver.
Move the 9-way to 9-way DSP MMI/RSS cable to the CTU2 TTY port of the next CTU2 to be calibrated and repeat the procedure from step 4. Remove the power meter and check that all antennas have been reconnected. Use the clear_cal_data command at the BSC, followed by the Site restoration procedure described in Chapter 2 to return the site to service. NOTE
The clear_cal_data command clears all calibration data out of the CM database. This is required to override the preserve calibration feature, if enabled. If the CTU2 is operating in double density mode, both DRIs must be cleared.
Maint. 324
29 Jan 2007
GSM
68P02902W06-C006
Maint. 325
GSM
The Cavity Combining Block (CCB) combines the output of up to three transceivers to a common output and up to six CTUs by use of an additional CCB (extension). The CCB extension output is an input to the CCB (output) for a single antenna system. Every transmitted frequency will be attenuated by approximately 3.5 dB for a six cavity system and 2.7 dB in a three cavity system. NOTE
CCBs are not used in GSM850 or PCS1900 cabinet configurations and cannot be used in conjunction with CTU2s.
A Horizonmacro indoor can support one or two CCB modules. There is a minimum of one CCB control board. The CCB control board is located at the front of the CCB beneath a screw-down cover. If redundancy of the CCB control board is provided, both CCB modules will be equipped with a CCB control board. The CCB has an address which is defined in the database using the equip_device COMB command. The address can also be displayed by using the disp_equipment COMB command. NOTE
All CCB commands are issued through the TTY port on a CTU.
The CCB control board has a set of eight DIP switches which are used to provide the binary representation of the address defined in the database. These switches have all been set to zero in the Preparing for test procedure. Once the cell site power has been set, the DIP switches should be returned to positions for the address defined in the database.
off 128
on 64
off 32
off 16
on 8
off 4
on 2
on 1
NOTE
If CCB control board redundancy is supported, the dip switches must be set the same on both CCB control boards. 255, all dip switches set to on, is not a valid address.
Maint. 326
29 Jan 2007
GSM
Calibration procedures
The procedures Tuning the CCB cavities, VSWR calibration procedure, Calibrating cell site power and Parking the CCB cavities should be used for VSWR and cell site calibration of Horizonmacro cabinets equipped with CTUs and CCB RF combiners. NOTE
The four calibration procedures should be completed sequentially, and without pause, for each transceiver. Failure to do so could result in the associated CCB being parked on the wrong channel.
68P02902W06-C006
Maint. 327
GSM
Type...
send eqcp 02 05 00 01 00 1F 00 27 send eqcp 02 05 00 01 02 BC 00 C6
Where: 02 is the parameter download message ID. 05 is the number of bytes to follow, excluding final checksum. 00 is the CCB address (as set on the DIP switches). 01 is the hex value of the address of the cavity to be tuned. (set for cavity 0). 00 is the channel high byte for CTU 900 (02 for CTU 1800). 1F is the channel low byte for a CTU 900 set to channel 31 (BC for a CTU 1800 set to channel 700). 00 is the power level always 00. 27 is the low byte of the checksum 02 + 05 + 00 + 01 + 00 + 1F + 00 for a CTU 900. (C6 is the low byte of checksum 02 + 05 + 00 + 01 + 02 + BC + 00 for a CTU 1800). The response should occur in under 12 seconds and begin with 01. A typical response, if OK, is:
01 04 00 01 00 00 06
Table Maint. 3-9 (CTU 900) and Table Maint. 3-10 (CTU 1800) detail the tuning commands for all possible cavities.
Maintenance and Parts: Horizonmacro indoor 68P02902W06-C006
Maint. 328
29 Jan 2007
GSM
CAUTION
To check the VSWR of the transmission path, perform the following steps: 1. 2. 3. 4. 5. 6. 7. At the EQCP TEST prompt, type CSPWR Monitor and record the wattmeter reading (the forward output power). Press ESC or CTRL-Y or CTRL-C. Replace the 50 W element in the wattmeter with a 5 W element and reverse the direction on the power meter. Remove the dummy load and connect the power meter through to the antenna. At the EQCP TEST prompt, type CSPWR Monitor and record the reverse power reading indicated on the power meter. NOTE
Readings should show reflected (reverse) power of no more than 5% of the forward power at the point of measurement, but less than 1 W. If the ratio of the forward and reverse readings is unacceptable, suspect an improper termination of the antenna feeder and connector.
8.
68P02902W06-C006
Maint. 329
GSM
2.
Enter U or D to adjust the CTU Tx power to achieve the appropriate value, as detailed in Table Maint. 3-8:
Table Maint. 3-8 Achievable Tx RF power output RF configuration Achievable value CTU 900 CTU 1800
16 W (42.1 dBm)
Or the customer-specified value at the top of the cabinet, taking cable losses into account.
As U or D is typed, a message similar to the following example, indicating the CTU output power and offset value, is displayed:
D P: 46.8 dBm Cell Site Offset: 1
When the required output level is achieved, press ESC or CTRL-Y or CTRL-C. 4. Save the transmit power calibration. At the EQCP TEST prompt type: HALT C WRENB SAVE CAL TX WRPTC
Maint. 330
29 Jan 2007
GSM
0 1 2 3 4 5
02 02 02 02 02 02
05 05 05 05 05 05
00 00 00 00 00 00
01 02 04 08 10 20
00 00 00 00 00 00
1F 1F 1F 1F 1F 1F
00 00 00 00 00 00
27 28 2A 2E 36 46
Table Maint. 3-10 CTU 1800 CCB cavity tuning commands Cavity to be tuned Cavity tuning command
0 1 2 3 4 5
02 02 02 02 02 02
05 05 05 05 05 05
00 00 00 00 00 00
01 02 04 08 10 20
02 02 02 02 02 02
BC BC BC BC BC BC
00 00 00 00 00 00
C6 C7 C9 CD D5 E5
Table Maint. 3-11 CTU 900 and CTU 1800 CCB cavity parking commands Cavity to be parked Cavity parking command
0 1 2 3 4 5
C2 C2 C2 C2 C2 C2
02 02 02 02 02 02
00 00 00 00 00 00
01 02 04 08 10 20
C5 C6 C8 CC D4 E4
1. 2.
Remove the power meter and reconnect the antenna. Use the Restoring the site procedure to return the site to service.
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 331
GSM
Site restoration
After all installed CTUs have been checked and calibrated, perform the following steps to restore the site: This is done in two stages:
S S
2. 3.
Press the reset button on the front panel of the CTU. Unlock the DRI under test using the following commands: unlock_device # dri A * state # DRI A * Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna.
This returns the CTU to the Unlocked_Busy state (confirmed by the state command). 6. 7. Monitor and record the wattmeter reading. This should be the same as the maximum power set up in step 3 of Calibrating cell site power. Lock the CTU by entering: lock_device # dri A * 0 Where:
# A *
is:
the number of the site logged into. the antenna/relative cell number (0 to 5). DRI number on the antenna.
Maint. 332
29 Jan 2007
GSM
68P02902W06-C006
Maint. 333
GSM
An IBM-compatible personal computer (PC). Terminal emulator software. A 9-way to 9-way cable (a diagram of this cable is provided in Figure Maint. 3-1 of the Test equipment, leads and plugs section). CAUTION
All test equipment and test leads must be calibrated annually by a recognized laboratory. Test equipment and test leads must not be calibrated in the field. Do not optimize Motorola cellular base stations with test equipment that is beyond its calibration due date. Allow test equipment to warm up for 30 minutes before use.
Commands used
The following commands are used during the procedure: disp_site disp_equipment
Displays the site number. Displays the active equipment at a specified site.
Maint. 334
29 Jan 2007
GSM
where # = the number of the site logged into. 2. At the CUST MMI prompt type: disp_equipment # where # = the number of the site logged into. A complete list of the equipment and functions in the database is displayed. For example:
CSFP BTP DRI DRI DRI DRI DRI DRI DRI DRI DRI DRI DRI DRI MSI MMS MMS MMS MMS MMS MMS RSL GCLK EAS CAB SITE PATH RTF RTF RTF RTF RTF RTF RTF RTF RTF RTF RTF RTF 000 000 000 010 020 030 100 110 120 130 200 210 220 230 000 000 010 020 030 040 050 000 000 000 000 000 000 000 010 020 030 100 110 120 130 200 210 220 230
(0 1 0) (0 0 0) (0 3 0) (0 2 0) (1 1 0) (1 0 0) (1 3 0) (1 2 0) (2 1 0) (2 0 0) (2 3 0) (2 2 0)
68P02902W06-C006
Maint. 335
GSM
3.
To check the MSI configuration at the CUST MMI prompt type: disp_equipment # MSI 0 0 Where: # = site number. A message similar to the following example is displayed:
MSI identifier: 0 MSI type [msi_type]: NIU2
Maint. 336
29 Jan 2007
GSM
An IBM compatible personal computer (PC). Terminal emulator software. A 9-way to 9-way cable (a diagram of this cable is provided in Figure Maint. 3-1 of the Test equipment, leads and plugs section). CAUTION
All test equipment and test leads must be calibrated annually by a recognized laboratory. Test equipment and test leads must not be calibrated in the field. Do not optimize Motorola cellular base stations with test equipment that is beyond its calibration due date. Allow test equipment to warm up for 30 minutes before use.
Commands used
The following command is used to carry out the procedure: state
Displays the status of specified devices or functions.
The system and the hardware are set up to check the E1/T1 links.
68P02902W06-C006
Maint. 337
GSM
S S
If the E1/T1 link has not been installed, perform this test at the DDF in the site. If no DDF is fitted, do this test at the top of the cabinet.
2. 3.
Ascertain the site number, equipment list and MMS configuration. At the CUST MMI prompt enter: state # MMS * * * Where:
# * * *
is:
location. dev/func id. dev/func id. dev/func id.
For example: state 2 MMS 0 1 0 The system displays the following message from the MCUF:
DEVICE STATUS INFORMATION FOR LOCATION 2: OPER STATES: D:Disabled E:Enabled B:Busy ADMIN STATES: L:Locked U:Unlocked E:Equipped
S:Shutdown
Last Transition Related Device State Reason dd/mm hh:mm:ss Function MMS 0 1 0 BU No reason 18/02 13:23:05 None
If this display shows Unlocked and Busy, then the NIU port (MMS), T43, cabling and the E1/T1 link are all good. If the loop is removed and the command re-entered, the result will be Unlocked and Disabled. NOTE
The NIU requires a minimum of 20 seconds after receiving these commands before it registers a change in status. If the display continues to show Unlocked and Busy, this may be because: 1. The wrong connection is looped, if the cabling is direct. 2. The MMS may be terminated by a device generating an E1/T1 link.
Maint. 338
29 Jan 2007
GSM
Preparing for the test. Testing the PIX connections using the database external alarm system (EAS).
An IBM compatible personal computer (PC). Terminal emulator software. A 9-way to 9-way cable (a diagram of this cable is provided in Figure Maint. 3-1 of the Test equipment, leads and plugs section. CAUTION
All test equipment and test leads must be calibrated annually by a recognized laboratory. Test equipment and test leads must not be calibrated in the field. Do not optimize Motorola Cellular Base Stations with test equipment that is beyond its calibration due date. Allow test equipment to warm up for 30 minutes before use.
Commands used
The following command is used to test the PIX connections: alarm_mode <site number> on disp_act_alarm <site number>
Enables alarm reporting for a specified site. Displays active alarms at the specified site.
equip <site number> Equip the external alarm system at the specified site. EAS
68P02902W06-C006
Maint. 339
GSM
is:
the site number.
2.
Connect a suitable test plug to the PIX input on the cabinet interface panel. NOTE
Wait at least six seconds before continuing the testing. The time is required to allow polling to detect the presence of the test plug.
3.
Type the disp_act_alarm command to view the alarms. The system displays all 8 alarms. NOTE
The display depends on the database settings, that is, whether a fault condition is indicated by a closed loop or an open loop.
4.
Change the state of each alarm using the test plug/lead. If the appropriate relay is operating correctly, the alarm state will change accordingly (alarm either cleared or activated). Remove the test plug. The system clears the alarm display.
5.
6.
Maint. 340
29 Jan 2007
Chapter 4
Parts information
68P02902W06-C006
Maint. 41
GSM
Maint. 42
29 Jan 2007
GSM
FRU items
The majority of items on the parts list are field replaceable units (FRUs). It is not intended to supply sub-units of these spares.
Ordering method
Contact the local Motorola office for ordering information, including cost and delivery. If an item in the parts list is marked TBA, this means that the part number for the item was not available at the time of publication of this manual. NOTE
Motorola reserves the right to change the design of the product without notice. The information provided in this chapter is intended as a guide. If the customer requires the latest information, then consult the Motorola local office who will be able to check on the web and confirm the current situation. Some items, for example CCBs and PSMs, are produced by different manufacturers, and so a replacement may appear slightly different to the item it is replacing. All items bearing the same order number, regardless of manufacturer, are fully compatible.
68P02902W06-C006
Maint. 43
GSM
14 50 OHM LOAD (FITTED TO UNUSED PORT) 7 T43/BIB 8 DIGITAL MODULE SHELF (see Figure Maint. 4-3)
13 TWO 2-FAN UNITS 12 3 x PSMs OR 2 x PSMs + HOLD-UP BATTERY MODULE 11 CIRCUIT BREAKER MODULE (CBM)
Maint. 44
29 Jan 2007
GSM
Spares tables
Table Maint. 4-1 to Table Maint. 4-5 list the Horizonmacro indoor spares, available as at October 2003. Location numbers in each table refer to the associated preceding diagram. Contact the Motorola local office for an up to date list.
Table Maint. 4-1 List of Horizonmacro indoor spares Location Description Order No
1 2 3 4 4 4 4 2 2 3 3 4 4 4 4 2 2 3 3 4 4 4 4 2 3 4 4 4 4 4
Indoor cabinet 1900 CTU 1900 SURF 1900 DCF 1900 DDF 1900 HCU 1900 TDF 1800 CTU 1800 CTU2 1800 SURF (single band) 1800 SURF (dual band) 1800 DCF 1800 DDF 1800 HCU 1800 TDF 900 CTU 900 CTU2 900 SURF (single band) 900 SURF (dual band) 900 DCF 900 DDF 900 HCU 900 TDF 850 CTU 850 SURF 850 DCF 850 DDF 850 HCU 850 TDF Dual band TDF
Maintenance and Parts: Horizonmacro indoor
SW1053 TBA TBA TBA TBA TBA TBA SWRG5197 SWRG9135 SWRG2880H SVRG1179H SVLG1224 SVLG1225 SVLG1227 SVLG1226 SWRF5193 SWRF9139 SWRF8352H SWRF2879H SVLF1224 SVLF1225 SVLF1227 SVLF1226 TBA TBA TBA TBA TBA TBA SVLX1198
29 Jan 2007
68P02902W06-C006
Maint. 45
GSM
Location
Description
Order No
5 6 7 7 8 9 9 9 10 11 12 12 12 12 13 14
Feedthrough plate assembly Indoor split sector cable pair BIM/BIB CIM/T43 Digital module shelf 2nd (Extension) cabinet fibre 3rd (Extension) cabinet fibre 4th (Extension) cabinet fibre 4-fan unit CBM Hold-up battery module Indoor 27 V PSM Indoor 48 V PSM Indoor 110/240 V PSM 2-fan unit SMA 50 ohm load Indoor plinth *Indoor blanks set PCMCIA Air filter kit (pack of 10) CTU/CTU2 Tx cable Duplexer cable
SVLN1243 SVKN1233 SWLN4024 SWLN4025 (see Table Maint. 4-3) SVKN1244 SVKN1245 SVKN1246 SWHN5790B SWHN5519 SVPN1161 SVPN1220 SVPN1221 SVPN1222 SWHN5289B SVLN1230 SVLN1247 SVLN1219 SWLN5239 SVFF1209 SVKN1304 SVKN1305
NOTE
*These are sets of blank plates which fit PSMs, Tx blocks and transceivers.
Maint. 46
29 Jan 2007
GSM
Figure Maint. 4-2 CCBs in installed position with CCB basket bar attached
CCB0 1 CCB1 1
2 2 CCB CONTROL 3 CCB BOARD INSTALLATION (REDUNDANT) KIT (BASKET) CCB CONTROL BOARD (MASTER)
ig.336.rh
1 1 1 1 2 3 NOTE
1800 CCB (Master) 1800 CCB (Extender) 900 CCB (Master) 900 CCB (Extender) CCB control board CCB installation kit
CCBs are not currently available for the GSM850 and PCS1900 BTS variants and cannot be used with CTU2s.
68P02902W06-C006
Maint. 47
GSM
1 ALARM MODULE
REDUNDANT (B)
2 MCUF A
MASTER (A)
5 BPSM
ig.322.rh
1 2 3 4 4 5
Maint. 48
29 Jan 2007
GSM
EXTERNAL VIEW
HONEYCOMB VENTILATION
VENTILATION GRID
TRIGGER LATCH
ig.266.rh
Door table
Table Maint. 4-4 outlines the door spare.
Table Maint. 4-4 Door spare Location Description Order No
Indoor door
SWHN5556
68P02902W06-C006
Maint. 49
GSM
Diagram of hood
Figure Maint. 4-5 shows a top view of the optional hood.
Figure Maint. 4-5 View of the hood as seen from the front of the cabinet
Indoor hood
SVLN1231
Maint. 410
29 Jan 2007
GSM
Glossary terms
BPSM Micro BCU Power Supply Module CBM Circuit Breaker Module CCB Cavity Combining Block CTU Compact Transceiver Unit CTU2 Compact Transceiver Unit 2 DCF Duplexed Combining bandpass Filter DDF Dual-stage Duplexed combining Filter FMUX Fibre optic Multiplexer HCU Hybrid Combining Unit HPD High Powered Duplexer MCUF Main Control Unit with dual FMUX NIU Network Interface Unit SURF Sectorized Universal Receiver Front-end TDF Twin Duplexed Filter
Maintenance and Parts: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
Maint. 411
GSM
Maint. 412
29 Jan 2007
Index
68P02902W06-C006
I1
GSM
I2
29 Jan 2007
GSM
A
Acronyms, main cabinet equipment, Tech. 14 Alarm module display, Tech. 627 extension cabinet, Tech. 626 functionality, Tech. 626 overview, Tech. 625 replacement, Maint. 272 replacement alarm, Tech. 626 view, Tech. 625 Alarms extension cabinets, Tech. 626 PSM, Tech. 46 Anchor bolts, torque values, Tech. 115
C
Cabinet dimensions, Tech. 118 weight, Tech. 115 Cage backplane, Tech. 29 replacement, Maint. 26 CAL port, MCUF, Tech. 69 Calibration, preserving on a transceiver, Maint. 225 CBIA attachment screws, Maint. 26 interface panel, Tech. 212 overview, Tech. 29 replacement, Maint. 26 CBM front panel diagram, Tech. 412 operation, Tech. 413 overview, Tech. 412 replacement, Maint. 215 CCB calibration, Maint. 326 control board, Tech. 548 functional diagram, Tech. 551 identification, TCB0 and TCB1, Maint. 269 overview, Tech. 548 replacement, Maint. 269 spares, Maint. 47 CCB basket, description, Tech. 222 CCB connector, pinouts, Tech. 215 CCB control board, removal, Maint. 270 Cell site power (CSPWR), Maint. 225 calibration, Maint. 315 CIM, pinouts, Tech. 217 CIM/BIM, (T43/BIB), Tech. 621 CINDY tool, Maint. 33 Circuit breaker module operation, Tech. 413 overview, Tech. 412 Cleaning, filter, Maint. 110 clear_cal_data command, output format, Maint. 314 Clearance, cabinet positioning, Tech. 118 CM database, viewing calibration data, Maint. 228
Service Manual: Horizonmacro indoor
B
Backplane cage, Tech. 29 function, Tech. 212 harness, Tech. 210 replacement, Maint. 26 Baseband hopping, Tech. 524 Battery backup, holdup module, optional BBS, Tech. 114 Bay level calibration, CTU/CTU2, Maint. 236 BDM port, MCUF, Tech. 69 BIB, pinouts, Tech. 215 BIM, pinouts, Tech. 215 Blanking plate replacement, Maint. 268 Tx block screws, Tech. 533 Boot code download, Tech. 610 CTU status LEDs, Tech. 512 CTU2, Tech. 518 BPSM dc power outputs, Tech. 415 LED display, Tech. 415 locations, Tech. 63 replacement, Maint. 272
29 Jan 2007
68P02902W06-C006
I3
GSM
Component identification, main cabinet, Tech. 1 5 Connectors torque values, Tech. 115 transceiver, Tech. 514 Control board, CCB, Tech. 548 CTU description, Tech. 511 front panel, Tech. 514 LED status indicators, Tech. 512 power output, Tech. 511 Rx bay level calibration procedures, Maint. 237 Rx function, Tech. 515 testing Rx circuitry, Tech. 510 Tx connector, Tech. 515 CTU/CTU2 preserving calibration, Maint. 225 replacement, Maint. 221 CTU2 description, Tech. 516 features, Tech. 516 front panel connectors, Tech. 520 interface function, Tech. 522 interface to SURF, Tech. 521 LED status indicators, Tech. 518 reset, Tech. 520 restrictions, Tech. 516 Rx bay level calibration procedures, Maint. 252 Rx function, Tech. 521 Tx connector, Tech. 521
Dimensions cabinet, Tech. 114 indoor cabinet, Tech. 118 site for cabinet, Tech. 118 Door locking angles, Maint. 18 operation, Maint. 18 replacement, Maint. 27 spares, Maint. 49 Door lock, replacement, Maint. 26 Door sensor, replacement, Maint. 26 Duplexing, Tech. 55
E
E1 NIU, Tech. 620 E1/T1 link, checking, Maint. 337 EGPRS, Tech. 523 EMC, containment, Maint. 268 Extension cabinets, alarm transmission, Tech. 626 External alarm connector, pinouts, Tech. 214 External alarms, shorting plug, Tech. 214
F
Fan, replacement, Maint. 213 Fan module, individual fan replacement, Maint. 2 6 Fans heat control, Tech. 33 temperature control, Tech. 34 Feedthrough plate replacement, Maint. 268 Tx block screws, Tech. 533 Fibre optic extension, top panel, Tech. 28 Filter, removal and cleaning, Maint. 110 FMUX connecting extension cabinets, Tech. 623 function, Tech. 624 internal to MCUF, Tech. 615 overview, Tech. 623 replacement, Maint. 272 FMUX fibre optic connections, MCUF, Tech. 69
D
Debug port, MCUF, Tech. 69 Digital boards power supply, Tech. 414 replacement, Maint. 272 Digital module shelf, spares, Maint. 48 Digital modules locations, Tech. 63 overview, Tech. 63 redundancy, Tech. 63
I4
29 Jan 2007
GSM
Frequency band characteristics, Tech. 116 Frequency hopping, description, Tech. 524 FRU CBM, Maint. 215 door, Maint. 27 fan, Maint. 213 hood, Maint. 210 PSM, Maint. 217 stacking bracket, Maint. 211 SURF, Maint. 262 Tx block, Maint. 265 FRUs, assumed procedures, Maint. 18
L
LAPD encoding, Tech. 620 LED status indicators, transceiver, Tech. 512, Tech. 518 Loopback test availability software, Tech. 510 functional diagram, Tech. 59 mode description, Tech. 510
M
MCell2, Use of MCUF as MCU, Tech. 66 MCell6 Horizonmacro compatibility, Tech. 19 Horizonmacro component comparison, Tech. 110 Use of MCUF as MCU, Tech. 66 MCUF code loading, Tech. 611 front panel interfaces, Tech. 69 front panel LEDs, Tech. 610 functional diagram, Tech. 68 GPROC functions, Tech. 67 link to redundant MCUF, Tech. 69 redundancy, Tech. 64 replacement, Maint. 272 synchronization circuit, Tech. 619 technical description, Tech. 66 Used as MCU, Tech. 66 view, Tech. 67 MCUF (GCLK), calibration, Maint. 279
G
GPS connector, pinouts, Tech. 214
H
Harness backplane, Tech. 210 cage, replacement, Maint. 26 HCU, replacement, Maint. 268 Heat control, cabinet, PSMs, CTUs, Tech. 33 Heat sensors description, Tech. 33 replacement, Maint. 29 Holdup battery module, Tech. 47 Hood Removal, Maint. 18 replacement, Maint. 210 spares, Maint. 410 Hybrid Combining Unit, Tx block screws, Tech. 533
N
Names, main cabinet equipment, Tech. 14 NIU block diagram, Tech. 618 connections to T43, Tech. 622 database identity, Tech. 616, Tech. 621 distance delay measurements, Tech. 619 front panel LEDs, Tech. 617 redundancy, Tech. 64 replacement, Maint. 272 reset, Tech. 619 TTY ports, Tech. 619
I
ICS connector, pinouts, Tech. 219 Indoor cabinet, dimensions, Tech. 114 Indoor cabinet , fans, Tech. 34 Interface panel As part of CBIA, Tech. 212 replacement, Maint. 26 Interfaces, MCUF front panel, Tech. 69
P
Parts list, introduction, Maint. 43
Service Manual: Horizonmacro indoor
29 Jan 2007
68P02902W06-C006
I5
GSM
PCMCIA interface, MCUF, Tech. 69 Pinouts BIB/BIM, Tech. 215 CCB connector, Tech. 215 external alarm connector, Tech. 214 GPS connector, Tech. 214 ICS connector, Tech. 219 PIX connectors, Tech. 218 T43/CIM, Tech. 217 PIX outputs and inputs, Tech. 218 test lead connections, Maint. 36 PIX alarms, checking, Maint. 339 PIX connectors, pinouts, Tech. 218 PIX outputs, MCUF, Tech. 610 Power consumption, Tech. 112 supply requirements, Tech. 112 Power supplies, BPSM, Tech. 414 Power Supply Module, technical information, Tech. 44 Power up, code load, Maint. 116 Preserve transceiver calibration data feature, Maint. 230 PSM alarms, Tech. 46 front panel LEDs, Tech. 46 replacement, Maint. 217 types, Tech. 44
Responses, CTU shutdown, Tech. 33 RF output power, Tech. 113 receive hardware, Tech. 54 test modes, Tech. 510 transmit hardware, Tech. 55
RF connections, torque values, Tech. 115 RF equipment, overview, Tech. 53 RF loopback, test function, Tech. 58 RF overview, Tech. 56 RF test function, functional diagram, Tech. 59
S
Sensitivity, Tech. 114 Sensors cabinet shut down, Tech. 33 fan control, Tech. 33 indoor temperature, Tech. 33 replacement, Maint. 29 SMA connector CTU, Tech. 515 CTU2, Tech. 521 Software requirements, Tech. 111 Spares, Maint. 45 introduction, Maint. 43 Specifications, Tech. 111 Stacking bracket description, Tech. 222 maintenance removal, Maint. 18 replacement, Maint. 211 Structural cosiderations, Tech. 118 SURF installing a replacement module, Maint. 264 module variants, Tech. 525 removal procedure, Maint. 263 replacement, Maint. 262 test mode, Tech. 510 module variants, Tech. 57 SURF (dual band), functional description, Tech. 531 SURF (single band), functional description, Tech. 528 SURF module, dual band capability, Tech. 531 Synthesizer hopping, Tech. 524
R
Replacement CBM, Maint. 215 door, Maint. 27 fan, Maint. 213 heat sensors, Maint. 29 hood, Maint. 210 PSM, Maint. 217 stacking bracket, Maint. 211 SURF, Maint. 262 Tx block, Maint. 265 Reporting faulty devices, Maint. 13 Reset, CTU2, Tech. 520 Reset button, transceiver, Tech. 514
I6
29 Jan 2007
GSM
T
T1 NIU, Tech. 620 T43, pinouts, Tech. 217 T43/BIB (CIM/BIM), Tech. 621 Connector to NIU, Tech. 621 TATI, Maint. 327 control board CCB, Tech. 548 TCB, set switch, Tech. 548 Temperature, environmental limits, Tech. 111 Temperature control fan unit description, Tech. 34 sensors, Tech. 33 Test frequency tables CTU, Maint. 242 CTU2, Maint. 259 Test leads, verification, Maint. 35 Tools, required for installation, Maint. 15 Top panel description, Tech. 28 fibre optic extension hole, Tech. 28 Torque values, general, Tech. 115
Transceiver bay level offset tables, Maint. 236 calibration procedure, Maint. 232 CTU description, Tech. 511 CTU2 description, Tech. 516 front panel, Tech. 514 preserve calibration data procedure, Maint. 231 recalibration procedure, Maint. 234 Rx function, Tech. 515 Rx functions, Tech. 54 Tx calibration, Maint. 37 Tx functions, Tech. 55 variants, Tech. 56 Transceiver link features, MCUF, Tech. 612 TTY interface, MCUF, Tech. 69 TTY port CTU2, Tech. 520 transceiver, Tech. 514 Tx block, Tech. 57 fitting a replacement module, Maint. 268 introduction, Tech. 533 replacement, Maint. 265 screw retention, Tech. 533 Type approval, Tech. 111
V
Verification, Maint. 33 VSWR CCBs, Maint. 326 checking, CTU, Maint. 315 VSWR test mode, Tech. 510
68P02902W06-C006
I7
GSM
I8
29 Jan 2007
Logo 1
The Environmental Friendly Use Period (EFUP) is the period (in years) during which the Toxic and Hazardous Substances (T&HS) contained in the Electronic Information Product (EIP) will not leak or mutate causing environmental pollution or bodily injury from the use of the EIP. The EFUP indicated by the Logo 2 label applies to a product and all its parts. Certain field-replaceable parts, such as battery modules, can have a different EFUP and are marked separately. The Disclosure Table is intended only to communicate compliance with China requirements; it is not intended to communicate compliance with EU RoHS or any other environmental requirements.
68P02901W00-E