Overview ............................................................................................................................... 2
1SBC101133S0201
Index ..................................................................................................................................... 88
ABB | 1
1SBC100155C0202 ShortForm.indb 1
08/10/2010 12:26:56
2 | ABB
1SBC100155C0202 ShortForm.indb 2
08/10/2010 12:27:02
Reducing energy consumption and protecting the environment has long been at the top of ABBs list of priorities, and
we are proud to introduce a first-class proposal.
ABB | 3
1SBC100155C0202 ShortForm.indb 3
08/10/2010 12:27:21
Softstarters
Protection by manual motor starters
or by fuses with overload relays
Star-delta starters
Protection by fuses with overload relays
4 | ABB
1SBC100155C0202 ShortForm.indb 4
08/10/2010 12:27:38
A
M
97
RESET
95
98
96
6/T3
4/T2
2/T1
Reset function
TEST
STOP
Test function
Stop function
KM1
KM2
01 NC
01NC
KM1
VEM4
A2
A2
KM2
ABB | 5
1SBC100155C0202 ShortForm.indb 5
08/10/2010 12:27:44
Types
MS116
MS132
Setting range
0.1 ... 16 A
0.1 ... 32 A
Switch position
ON / OFF
ON / OFF / TRIP
yes
yes
up to 50 kA
up to 100 kA
Trip class
10A
10
Thermal tripping
Handle in
TRIP position
TRIP indication
Lockable handle
without accessory
Handle in
TRIP position
Test function
Magnetic tripping
Optical indication
in I >> window
Current setting
6 | ABB
1SBC100155C0202 ShortForm.indb 6
08/10/2010 12:28:03
Types
30 A
7.5 hp 10 hp
45 A
50 A
50 A
15 hp
20 hp
20 hp
AF operating limits
Conventional
operating limits
AF09
Z - 30 - 10 - 21
1.1 x Uc (253 V)
Uc max. (250 V)
Uc = 220...230 V
50 Hz
Uc min. ... Uc max. =
100...250 V
50/60 Hz - DC
Auxiliary contacts
N.O. / N.C.
Contactor type
AC / DC
AC
AC
0.85 x Uc (187 V)
Uc min. (100 V)
0.85 x Uc min. (85 V)
Coil code
21
12
13
14
1SBC100155C0202 ShortForm.indb 7
08/10/2010 12:28:09
Non-removable
protective covers
(BX4-CA) for
auxiliary contact
blocks
Contactor relay
type
NF
Auxiliary contacts
N.O. / N.C.
Z 22 E - 21
Coil code
21
12
13
14
8 | ABB
1SBC100155C0202 ShortForm.indb 8
08/10/2010 12:28:18
PSR softstarters
Compact design with 3 frame sizes
PSR3
...
PSR16
Types
PSR25,
PSR30
PSR37
Rated operational
1.5 ... 7.5 kW 11 ... 15 kW
power 400 V AC-53a
18.5 kW
UL 3-phase
motor power - 480 V
25 hp
2 ... 10 hp
15 ... 20 hp
Uini
time
Start
Stop
ABB | 9
1SBC100155C0202 ShortForm.indb 9
08/10/2010 12:28:30
10 | ABB
1SBC100155C0202 ShortForm.indb 10
08/10/2010 12:28:41
1SBC101132S0201
Dimensions............................................................................................................................... 40
ABB | 11
1SBC100155C0202 ShortForm.indb 11
08/10/2010 12:28:48
Reversing Starters
I>
MS...
Manual motor starter
MS...
Manual motor starter
BEA...
Connecting link
BEA...
Connecting link
BER..-4
Connection set
AF...
Contactor
AF...
Contactor
VEM4
mechanical &
electrical
interlock set
A2-A2
Connection
Reversing Starters
Star-Delta Starters
L
BER..-4
Connection set
On-delay timer
AF...
Contactor
A2-A2
Connection
AF...
Contactor
VEM4
mechanical &
electrical
interlock set
VEM4
mechanical &
electrical
interlock set
TF42
Thermal overload relay
AF...
Contactor
BEY..-4
Connection set
TF42
Thermal overload relay
VEM4 mechanical and electrical interlock set including: VM4 mechanical interlock unit including 2 fixing clips and VE4 electrical interlock block with A2-A2 connection
TF42
Thermal overload relay
12 | ABB
1SBC100155C0202 ShortForm.indb 12
08/10/2010 12:28:54
Direct-On-Line Starters
Reversing Starters
0.06 ... 15 kW
0.06 ... 15 kW
Short-circuit current Iq
16 kA - 50 kA
16 kA - 50 kA
Coordination type
Manual motor starters
Contactors
AC / DC Operated
Direct-On-Line Starters
Reversing Starters
Starters Protected
by Thermal Overload Relays
AC / DC Operated
4 ... 18.5 kW
4 ... 18.5 kW
TF42
TF42
Star-Delta Starters
7.5 ... 25 kW
AC / DC Operated
timer
Starters Protected
by Manual Motor Starters
1SBC100155C0202 ShortForm.indb 13
08/10/2010 12:28:59
Application
CE
Full voltage direct-on-line starting for controlling three-phase asynchronous motors is a simple and economic
solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7
times nominal current.
I/In C/Cn
7
6
I>
I
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
2
10
30
60
80
100
Coordination Types
The contactor and the manual motor starter control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service
continuity as follow:
MS132-10 + BEA16-4 + AF16-30-10
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will
not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will
be able to operate afterwards. The risk of contacts light welding is acceptable.
690 V - 50/60 Hz
690 V
Switching frequency
IP 20
Mounting positions
+30
-30
Pos. 2
Pos. 4
Pos. 3
Pos. 1
Pos. 1 30
Pos. 5
14 | ABB
1SBC100155C0202 ShortForm.indb 14
08/10/2010 12:29:02
Description
You can easily assemble a direct-on-line starter by using the BEA..-4 connecting link
3-pole insulated. It is used to electrically and mechanically connect MS... manual motor
starter and AF... contactor, AC or DC operated.
I>
Select now easily and quickly your starter in the following pages for coordination
type 1 or 2 at 400 V, 50 / 60 Hz, Iq = 16 kA or Iq = 50 kA up to 15 kW.
MS...
Manual motor starter
For complete coordination tables, please contact your ABB local sales organization.
BEA...
Connecting link
AF...
Contactor
Wiring Diagrams
KM1:5/L3
33
43
44
5/L3
Us
34
3/L2
1/L1
43
44
5/L3
33
34
3/L2
1/L1
KM1:5/L3
33
Q1
34
Us
33
Q1
34
~
Power circuit
14
14
5/L3
6/T3
KM1
43
Q1
44
KM1
AC or DC local control
Us
N
43
Q1
44
KM1
A2
Us
N
A2
14
A1
A1
13
3/L2
4/T2
14
KM1
KM1:3/L2
V
13
13
6/T3
4/T2
1/L1
2/T1
5/L3
6/T3
A1
13
4/T2
3/L2
4/T2
6/T3
2/T1
1/L1
2/T1
A2
KM1
2/T1
Q1
KM1:3/L2
AC or DC remote control
~
1-phase
ABB | 15
1SBC100155C0202 ShortForm.indb 15
08/10/2010 12:29:03
AC-3
400 V
Contactors
Accessories
I>
BEA..-4
IEC
Type
(1)
AC-3, 400 V
Rated Rated
power current
kW
Order code
Current
setting
range
Type
Order code
V 50/60 Hz V DC
Allowed
setting
current
CA4-10
Type
Order code
BEA16-4
BEA38-4
+
CA4-10
Iq = 16 kA
Iq = 50 kA
0.06
0.2
0.16...0.25 2.44
24...60
20...60
0.3
MS132-0.4
0.25...0.40 3.9
24...60
20...60
0.44
0.40...0.63 6.14
24...60
20...60
0.18
0.6
0.40...0.63 6.14
24...60
20...60
0.25
0.85
MS132-1.0
0.63...1.00 11.5
24...60
20...60
0.37
1.1
MS132-1.6
1.00...1.60 18.4
24...60
20...60
0.55
1.5
MS132-1.6
1.00...1.60 18.4
24...60
20...60
0.75
1.9
MS132-2.5
1.60...2.50 28.75
24...60
20...60
1.1
2.7
MS132-4.0
2.50...4.00 50
24...60
20...60
1.5
3.6
MS132-4.0
2.50...4.00 50
24...60
20...60
2.2
4.9
MS132-6.3
4.00...6.30 78.75
24...60
20...60
6.5
MS132-10
6.30...10.0 150
24...60
20...60
8.5
MS132-10
6.30...10.0 150
24...60
20...60
5.5
11.5
MS132-12
8.00...12.0 180
24...60
20...60
7.5
15.5
MS132-16
10.0...16.0 240
24...60
20...60
11
22
MS132-25
20.0...25.0 375
24...60
20...60
15
29
MS132-32
25.0...32.0 480
24...60
20...60
25
16
12
6.3
2.5
1.6
1.6
0.63
0.63
0.4
0.25
32
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 7.5 kW, 400 V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
(2) For other control voltages, see "3-pole contactors - Ordering details" pages.
16 | ABB
1SBC100155C0202 ShortForm.indb 16
08/10/2010 12:29:06
AC-3
400 V
Contactors
Accessories
I>
BEA..-4
IEC
Type
(1)
AC-3, 400 V
Rated Rated
power current
kW
Order code
Current
setting
range
Type
(3)
Order code
V 50/60 Hz V DC
Allowed
setting
current
CA4-10
Type
Order code
BEA16-4
BEA26-4
+
CA4-10
BEA38-4
+
CA4-10
(4)
Iq = 16 kA
Iq = 50 kA
0.06
0.2
0.16...0.25 2.44
24...60
20...60
0.3
MS132-0.4
0.25...0.40 3.9
24...60
20...60
0.44
0.40...0.63 6.14
24...60
20...60
0.18
0.6
0.40...0.63 6.14
24...60
20...60
0.25
0.85
MS132-1.0
0.63...1.00 11.5
24...60
20...60
0.37
1.1
MS132-1.6
1.00...1.60 18.4
24...60
20...60
0.55
1.5
MS132-1.6
1.00...1.60 18.4
24...60
20...60
0.75
1.9
MS132-2.5
1.60...2.50 28.75
24...60
20...60
1.1
2.7
MS132-4.0
2.50...4.00 50
24...60
20...60
1.5
3.6
MS132-4.0
2.50...4.00 50
24...60
20...60
2.2
4.9
MS132-6.3
4.00...6.30 78.75
24...60
20...60
6.5
MS132-10
6.30...10.0 150
24...60
20...60
8.5
MS132-10
6.30...10.0 150
24...60
20...60
5.5
11.5
MS132-12
8.00...12.0 180
24...60
20...60
7.5
15.5
MS132-16
10.0...16.0 240
24...60
20...60
11
22
MS132-25
20.0...25.0 375
24...60
20...60
15
29
MS132-32
25.0...32.0 480
24...60
20...60
25
16
12
10
10
6.3
2.5
1.6
1.6
0.63
0.63
0.4
0.25
32
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 7.5 kW, 400 V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
(2) For other control voltages, see "3-pole contactors - Ordering details" pages.
(3) AF26... 3-pole contactor can be selected for coordination type 2, 16 kA, 7.5 kW, 400 V - AC-3.
(4) BEA38-4 cannot be selected with MS116 manual motor starters.
ABB | 17
1SBC100155C0202 ShortForm.indb 17
08/10/2010 12:29:08
Application
CE
Full voltage reversing starting for controlling three-phase asynchronous motors is a simple and economic solution
characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times
nominal current.
I/In C/Cn
7
6
I>
I
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
2
10
30
60
80
100
Coordination Types
The contactor and the manual motor starter control and protect motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of service
continuity as follow:
MS132-10 + BEA16-4 + BER16-4 + VEM4
+ AF16-30-10
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will
not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will
be able to operate afterwards. The risk of contacts light welding is acceptable.
690 V - 50/60 Hz
690 V
Switching frequency
IP 20
Mounting positions
+30
-30
Pos. 2
Pos. 4
Pos. 3
Pos. 1
Pos. 1 30
Pos. 5
18 | ABB
1SBC100155C0202 ShortForm.indb 18
08/10/2010 12:29:10
Description
You can easily assemble reversing starter thanks to our complete range of
accessories:
BEA..-4 connecting link 3-pole insulated: it is used to electrically and
mechanically connect MS... manual motor starter and AF contactor, AC
or DC operated.
I>
MS...
Manual Motor Starter
Fixing clip
Select now easily and quickly your starter in the following pages for
coordination type 1 or 2 at 400 V, 50 / 60 Hz, Iq = 16 kA or Iq = 50 kA up
to 15 kW.
VM4
Mechanical
interlock unit
For complete coordination tables, please contact your ABB local sales
organization.
AF...
Contactor
VE4
Electrical
interlock block
A2
BER..-4
Connection set
A2
Wiring Diagrams
5/L3
33
43
44
KM2:5/L3
33 Q1 34
Us
34
3/L2
1/L1
KM2:5/L3
33 Q1 34
Us
Q1
O
.3
3/L2
5/L3
4/T2
6/T3
.4
Us
N
43 Q1 44
KM1
A2
(1)
A2
(3)
AC or DC local control
V
.4
.4
01
01
(2)
(2)
KM2:3/L2
01
01
(2)
KM2
(2)
.3
1/L1
2/T1
A2
.4
6/T3
4/T2
2/T1
A1
.3
5/L3
3/L2
1/L1
A1
KM2
A2
KM1
KM1
KM2
II
.4
KM1
.4
.3
.3
6/T3
4/T2
2/T1
.3
II
KM2
KM1
Us
N
43 Q1 44
A2
(1)
KM2
A2
(3)
KM2:3/L2
AC or DC remote control
Power circuit
ABB | 19
1SBC100155C0202 ShortForm.indb 19
08/10/2010 12:29:13
AC-3
400 V
Contactors
Accessories
+
I>
BEA..-4
BER..-4
VEM4
IEC
Type
(1)
AC-3, 400 V
Rated Rated
power current
kW
Order code
Current
setting
range
Type
Order code
V 50/60 Hz V DC
Allowed
setting
current
CA4-10
Type
Order code
BEA16-4
+
BER16-4
+
VEM4
BEA38-4
+
BER38-4
+
VEM4
+
2x CA4-10
Iq = 16 kA
Iq = 50 kA
0.06
0.2
0.16...0.25 2.44
24...60
20...60
AF09Z-30-10-21
0.3
MS132-0.4
0.25...0.40 3.9
24...60
20...60
AF09Z-30-10-21
0.44
0.40...0.63 6.14
24...60
20...60
AF09Z-30-10-21
0.6
0.40...0.63 6.14
24...60
20...60
AF09Z-30-10-21
0.85
MS132-1.0
0.63...1.00 11.5
24...60
20...60
AF09Z-30-10-21
1.1
MS132-1.6
1.00...1.60 18.4
24...60
20...60
AF09Z-30-10-21
1.5
MS132-1.6
1.00...1.60 18.4
24...60
20...60
AF09Z-30-10-21
1.9
MS132-2.5
1.60...2.50 28.75
24...60
20...60
AF09Z-30-10-21
2.7
MS132-4.0
2.50...4.00 50
24...60
20...60
AF09Z-30-10-21
3.6
MS132-4.0
2.50...4.00 50
24...60
20...60
AF09Z-30-10-21
4.9
MS132-6.3
4.00...6.30 78.75
24...60
20...60
AF09Z-30-10-21
6.5
MS132-10
6.30...10.0 150
24...60
20...60
AF09Z-30-10-21
8.5
MS132-10
6.30...10.0 150
24...60
20...60
AF09Z-30-10-21
11.5
MS132-12
8.00...12.0 180
24...60
20...60
AF12Z-30-10-21
15.5
MS132-16
10.0...16.0 240
24...60
20...60
AF16Z-30-10-21
22
MS132-25
20.0...25.0 375
24...60
20...60
AF26Z-30-00-21
29
MS132-32
25.0...32.0 480
24...60
20...60
AF30Z-30-00-21
0.25
0.4
0.63
0.63
1.6
1.6
2.5
6.3
12
16
25
32
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to :
- 7.5 kW, 400 V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
(2) For other control voltages, see "3-pole contactors - Ordering details" pages.
20 | ABB
1SBC100155C0202 ShortForm.indb 20
08/10/2010 12:29:16
AC-3
400 V
Contactors
Accessories
+
I>
BEA..-4
BER..-4
VEM4
IEC
Type
(1)
AC-3, 400 V
Rated Rated
power current
kW
Order code
Current
setting
range
Type
(3)
Order code
V 50/60 Hz V DC
Allowed
setting
current
CA4-10
Type
Order code
BEA16-4
+
BER16-4
+
VEM4
BEA26-4
+
BER38-4
+
VEM4
+
2x CA4-10
BEA38-4
+
BER38-4
+
VEM4
+
2x CA4-10
(4)
Iq = 16 kA
Iq = 50 kA
0.06
0.2
0.16...0.25 2.44
24...60
20...60
AF09Z-30-10-21
0.3
MS132-0.4
0.25...0.40 3.9
24...60
20...60
AF09Z-30-10-21
0.44
0.40...0.63 6.14
24...60
20...60
AF09Z-30-10-21
0.6
0.40...0.63 6.14
24...60
20...60
AF09Z-30-10-21
0.85
MS132-1.0
0.63...1.00 11.5
24...60
20...60
AF09Z-30-10-21
1.1
MS132-1.6
1.00...1.60 18.4
24...60
20...60
AF09Z-30-10-21
1.5
MS132-1.6
1.00...1.60 18.4
24...60
20...60
AF09Z-30-10-21
1.9
2.7
MS132-2.5
MS132-4.0
1.60...2.50 28.75
2.50...4.00 50
24...60
20...60
AF09Z-30-10-21
3.6
MS132-4.0
2.50...4.00 50
4.9
MS132-6.3
4.00...6.30 78.75
24...60
20...60
AF26Z-30-00-21
24...60
20...60
AF26Z-30-00-21
6.5
MS132-10
6.30...10.0 150
24...60
20...60
AF26Z-30-00-21
8.5
MS132-10
6.30...10.0 150
24...60
20...60
AF26Z-30-00-21
11.5
MS132-12
8.00...12.0 180
24...60
20...60
AF26Z-30-00-21
15.5
MS132-16
10.0...16.0 240
24...60
20...60
AF30Z-30-00-21
22
MS132-25
20.0...25.0 375
24...60
20...60
AF30Z-30-00-21
29
MS132-32
25.0...32.0 480
24...60
20...60
AF30Z-30-00-21
0.63
0.63
1.6
1.6
AF26Z-30-00-21
0.4
24...60
20...60
0.25
2.5
4
6.3
10
10
12
16
25
32
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 7.5 kW, 400 V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
(2) For other control voltages, see "3-pole contactors - Ordering details" pages.
(3) AF26... 3-pole contactor can be selected for coordination type 2, 16 kA, 7.5 kW, 400 V - AC-3.
(4) BEA38-4 cannot be selected with MS116 manual motor starters
ABB | 21
1SBC100155C0202 ShortForm.indb 21
08/10/2010 12:29:20
4.5 0.18"
M4 8-32UNC
5.5
0.22"
10
0.39"
186.8 7.35"
45 1.77"
10
0.39"
75
2.95"
70 2.76"
35 mm EN/IEC 60715
188 7.40"
17.5
0.69"
6
0.24"
80.1 3.15"
26.25
1.03"
5
0.20"
5
0.20"
4.2 0.17"
M4 8-32UNC
5.5 0.22"
45 1.77"
77 3.03"
5
0.20"
35
1.38"
5
0.20"
MS116
+ BEA16-4
+ AF09, AF12, AF16
6
0.24"
4.5 0.18"
M4 8-32UNC
17.5
0.69"
26.25
1.03"
10 0.39"
10
0.39"
186.8 7.35"
186.8 7.35"
45 1.77"
10 0.39"
5.5
0.22"
26.25
1.03"
4.2 0.17"
M4 8-32UNC
4.2 0.17"
M4 8-32UNC
5
0.20"
86 3.39"
5.5 0.22"
35
1.38"
5
0.20"
5
0.20"
45 1.77"
86 3.39"
5
0.20"
5
0.20"
5.5 0.22"
5
0.20"
45 1.77"
4.5 0.18"
M4 8-32UNC
10
0.39"
75
2.95"
35 mm EN/IEC 60715
5.5
0.22"
192 7.56"
188 7.40"
35 mm EN/IEC 60715
45 1.77"
75
2.95"
70 2.76"
6
0.24"
81.1 3.19"17.5
72.2 2.84" 0.69"
80.1 3.15"
5
0.20"
35
1.38"
5
0.20"
MS116
+ BEA26-4
+ AF26, AF30, AF38
22 | ABB
1SBC100155C0202 ShortForm.indb 22
08/10/2010 12:29:22
45 1.77"
10
0.39"
4.5 0.18"
M4 8-32UNC
5.5
0.22"
186.8 7.35"
35 mm EN/IEC 60715
26.25
1.03"
17.5
0.69"
6
0.24"
72.2 2.84"
75
2.95"
192 7.56"
10 0.39"
186.8 7.35"
5.5
0.22"
35 mm EN/IEC 60715
10 0.39"
26.25
1.03"
4.2 0.17"
M4 8-32UNC
5.5 0.22"
77 3.03"
5
0.20"
35
1.38"
5
0.20"
35
1.38"
86 3.39"
35
1.38"
5
45 1.77"
0.20"
4.5 0.18"
M4 8-32UNC
45 1.77"
10
0.39"
10
0.39"
17.5
0.69"
26.25
1.03"
4.2 0.17"
M4 8-32UNC
5.5 0.22"
45 1.77"
86 3.39"
5.5 0.22"
86 3.39"
5
0.20"
35
1.38"
5
0.20"
5
0.20"
4.2 0.17"
M4 8-32UNC
5
0.20"
5
0.20"
186.8 7.35"
26.25
1.03"10 0.39"
5
0.20"
5
0.20"
5.5 0.22"
4.5 0.18"
M4 8-32UNC
6
0.24"
6
0.24"
10 0.39"
4.2 0.17"
M4 8-32UNC
45 1.77"
5
0.20"
5.5
0.22"
186.8 7.35"
26.25
1.03"
17.5
0.69"
72.2 2.84"
35 mm EN/IEC 60715
5.5
0.22"
192
357.56"
mm EN/IEC 60715
192 7.56"
186.8 7.35"
10 0.39"
81.1 3.19"
81.1 3.19"
72.2 2.84"
45 1.77"
10
0.39"
4.5 0.18"
M4 8-32UNC
5.5
0.22"
35 mm EN/IEC 60715
45 1.77"
77 3.03"
75
2.95"
17.5
0.69"
6
0.24"
72.4 2.85"
75
2.95"
5.5 0.22"
81.3 3.20"
188 7.40"
5
45 1.77"
0.20"
75
2.95"
45 1.77"
5
0.20"
5
0.20"
5
0.20"
5
0.20"
4.2 0.17"
M4 8-32UNC
5
5
0.20"
0.20"
45 1.77"
81.1 3.19"
4.5 0.18"
M4 8-32UNC
10
0.39"
75
2.95"
188 7.40"
17.5
0.69"
6
0.24"
81.3 3.20"
72.4 2.85"
5
0.20"
35
1.38"
5
0.20"
ABB | 23
1SBC100155C0202 ShortForm.indb 23
08/10/2010 12:29:25
75
2.95"
4.5 0.18"
M4 8-32UNC
45 1.77"
10
0.39"
70 2.76"
186.8 7.35"
5.5
0.22"
35 mm EN/IEC 60715
189.5 7.46"
17.5
0.69"
6
0.24"
97 3.82"
80.1 3.15"
10
0.39"
26.25
1.03"
5
0.20"
5
0.20"
4.2 0.17"
M4 8-32UNC
3,8
0.15"
90 3.54"
5
0.20"
35
1.38"
5
0.20"
114 4.49"
80.1 3.15"
4.5 0.18"
M4 8-32UNC
4.5 0.18"
M4 8-32UNC
26.25
1.03"
5
0.20"
5
0.20"
10
26.25
0.39"
1.03"
90 3.54"
5
0.20"
80
3.15"
5
5
0.20" 0.20"
5
0.20"
5
0.20"
4.2 0.17"
M4 8-32UNC
5
0.20"
5
0.20"
4.2 0.17"
M4 8-32UNC
70
2.76"
70
2.76"
10
0.39"
198 7.80"
5.5
0.22"
198 7.80"
35 mm EN/IEC 60715
17.5
0.69"
10
0.39"
70 2.76"
45 1.77"
5.5
0.22"
17.5
0.69"
10
0.39"
70 2.76"
35 mm EN/IEC 60715
198 7.80"
198 7.80"
45 1.77"
75
2.95"
75
2.95"
114 4.49"
80.1 3.15"
6
0.24"
6
0.24"
MS116
+ BEA16-4, BER16-4, VEM4
+ AF09, AF12, AF16
80
3.15"
5
0.20"
5.5 0.22"
MS116
+ BEA26-4, BER38-4, VEM4, CA4-10
+ AF26, AF30, AF38
24 | ABB
1SBC100155C0202 ShortForm.indb 24
08/10/2010 12:29:27
81.1 3.19"
17.5
0.69"
4.5 0.18"
M4 8-32UNC
10
0.39"
10
0.39"
72.2 2.84"
45 1.77"
26.25
1.03"
70
2.76"
5
0.20"
10
0.39"
5
0.20"
26.25
1.03"
70
2.76"
10
0.39"
5.5
0.22"
35 mm EN/IEC 60715
186.8 7.62"
7.35"
193.5
35 mm EN/IEC 60715
5.5
0.22"
186.8 7.35"
45 1.77"
72.4 2.85"
6
0.24"
4.5 0.18"
M4 8-32UNC
75
75
2.95"
189.5 7.46"
17.5
0.69"
2.95"
6
0.24"
97 3.82"
97 3.82"
81.3 3.20"
4.2 0.17"
M4 8-32UNC
45 1.77"
45 1.77"
5
0.20"
5
0.20"
5
0.20"
10
10
0.39"
0.39"
5.55.5
0.22"
0.22"
26.25
26.25
1.03"
1.03"
5
5
0.20"
0.20"
10 10
0.39"
0.39"
70
2.76"
5
0.20"
26.25
1.03"
4.5
0.18"
4.5
0.18"
8-32UNC
M4M4
8-32UNC
70
70
2.76"
2.76"
201.5 7.93"
201.5
186.87.93"
7.35"
10
0.39"
17.5
17.5
0.69"
0.69"
72.2
2.84"
72.2
2.84"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
5,5 0.22"
35 mm EN/IEC 60715
81.1
3.19"
81.1
3.19"
10
0.39"
72.4 2.85"
4.49"
114114
4.49"
4.5 0.18"
M4 8-32UNC
6
6
0.24"
0.24"
17.5
0.69"
186.8 7.35"
186.8 7.35"
6
0.24"
75
2.95"
81.3 3.20"
45 1.77"
80
3.15"
5
0.20"
114 4.49"
198 7.80"
5
0.20"
75
75
2.95"
2.95"
80
90 3.54"
3.15"
5
0.20"
3.8
0.15"
3.8
0.15"
90 3.54"
5
0.20"
5
0.20"
4.2 0.17"
M4 8-32UNC
5
0.20"
80
3.15"
3.54"
90 90
3.54"
5
0.20"
0.22"
5.55.5
0.22"
5
5
0.20"
0.20"
5
0.20"
5
0.20"
5.5 0.22"
5 5
0.20"
0.20"
5
5
0.20"
0.20"
4.2
0.17"
4.2
0.17"
8-32UNC
M4M4
8-32UNC
4.2 0.17"
M4 8-32UNC
80 80
3.15"
3.15"
5 5
0.20"
0.20"
ABB | 25
1SBC100155C0202 ShortForm.indb 25
08/10/2010 12:29:31
Application
CE
Full voltage direct-on-line and reversing starting for controlling three-phase asynchronous motors is a simple and
economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current
5.5 to 7 times nominal current.
I/In C/Cn
7
6
I
5
4
3
2
I = current
C = torque
In = nominal current
Cn = nominal torque
10
30
60
80
100
AF16-30-10 + TF42
Coordination Types
The contactor, the short-circuit protection device and the thermal overload relay control and protect motors against
overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the
anticipated level of service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will not
be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will be
able to operate afterwards. The risk of contacts light welding is acceptable.
690 V - 50/60 Hz
690 V
60 C (above 38 A 50 C)
Degree of protection
IP 20
Switching Frequency
140
Mounting positions
Direct-on-line
Example:
Starting time of the motor: 1 second Duty ratio: 40%
means a permitted switching frequency of max. 60
operating cycles per hour.
Standards
Ta
=
120
0.
5
100
Ta =
80
1s
60
Ta =
1.5 s
40
Ta = 3 s
20
Ta = 5 s
0
0
10
20
30
40
50
60
70
80
90
100
Pos. 1
Reversing
Pos. 1
26 | ABB
1SBC100155C0202 ShortForm.indb 26
08/10/2010 12:29:34
Description
Reversing Starters
Fixing clip
A2
AF...
Contactor
AF...
Contactors
A2
VM4
Mechanical
interlock
unit
TF42
Thermal overload relay
TF42
Thermal
overload relay
BER..-4
Connection set
Wiring Diagrams
Direct-On-Line Starters
96
FR1
STOP
13
14
Power circuit
1-phase
A1 14
KM1
Us
N
KM1
Us
N
A2
4/T2
A1
2/T1
6/T3
6/T3
4/T2
2/T1
98
96
TEST
STOP
KM1
FR1
FR1
A2
KM1
97
13
A
95
RESET
FR1
14
6/T3
4/T2
2/T1
14
6/T3
4/T2
2/T1
RESET
95
96
13
95
5/L3
3/L2
1/L1
5/L3
13
A1
RESET
KM1:5/L3
Us
STOP
A2
KM1
3/L2
1/L1
KM1:5/L3
Us
KM1:3/L2
KM1:3/L2
AC or DC local control
AC or DC remote control
96
FR1
A
M
STOP
FR1
.4
.4
.4
.4
97
01
A2
KM1:3/L2
(1)
(3)
AC or DC local control
KM2
A2
01
01
(2)
(2)
6/T3
4/T2
98
2/T1
U VW
Power circuit
KM1
KM2
.4
KM1
KM2
II
.3
.3
.3
.3
6/T3
4/T2
A2
95
96
Us
N
KM1
01
(2)
FR1
TEST
STOP
RESET
95
95
II
I
A
RESET
M
KM1:5/L3
Us
96
5/L3
STOP
.3
3/L2
1/L1
RESET
O
2/T1
6/T3
4/T2
2/T1
KM2
A1
.3
5/L3
KM1:5/L3
Us
.4
A1
A2
KM1
3/L2
1/L1
Reversing Starters
Us
N
KM1
A2
KM1:3/L2
(2)
(1)
KM2
A2
(3)
AC or DC remote control
ABB | 27
1SBC100155C0202 ShortForm.indb 27
08/10/2010 12:29:37
IEC
AC-3, 400 V
Rated Rated
power current
Control voltage
Uc min. ... Uc max.
kW
4
V 50/60 Hz V DC
24...60
20...60
48...130
48...130
AF09-30-10-12
100...250
100...250
AF09-30-10-13
250...500
250...500
AF09-30-10-14
24...60
20...60
48...130
48...130
AF12-30-10-12
100...250
100...250
AF12-30-10-13
250...500
250...500
AF12-30-10-14
24...60
20...60
48...130
48...130
AF16-30-10-12
100...250
100...250
AF16-30-10-13
250...500
250...500
AF16-30-10-14
24...60
20...60
48...130
48...130
AF26-30-00-12
100...250
100...250
AF26-30-00-13
250...500
250...500
AF26-30-00-14
24...60
20...60
48...130
48...130
AF30-30-00-12
100...250
100...250
AF30-30-00-13
250...500
250...500
AF30-30-00-14
24...60
20...60
48...130
48...130
AF38-30-00-12
100...250
100...250
AF38-30-00-13
250...500
250...500
AF38-30-00-14
5.5
7.5
11
15
18.5
A
8.5
11.5
15.5
22
29
35
Type
Order code
Setting
ranges
Type
Order code
A ... A
7.60 ... 10.0
TF42-10
TF42-13
TF42-16
TF42-24
TF42-35
AC-3
400 V
Accessories
(1)
(1) For other control voltages, see "3-pole contactors - Ordering details" pages.
Setting ranges
Type
Order code
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
A ... A
0.10 ... 0.13
0.13 ... 0.17
0.17 ... 0.23
0.23 ... 0.31
0.31 ... 0.41
0.41 ... 0.55
0.55 ... 0.74
0.74 ... 1.00
1.00 ... 1.30
1.30 ... 1.70
1.70 ... 2.30
2.30 ... 3.10
3.10 ... 4.20
4.20 ... 5.70
5.70 ... 7.60
7.60 ... 10.0
10.0 ... 13.0
13.0 ... 16.0
16.0 ... 20.0
20.0 ... 24.0
24.0 ... 29.0
29.0 ... 35.0
35.0 ... 38.0/40.0
28 | ABB
1SBC100155C0202 ShortForm.indb 28
08/10/2010 12:29:40
AC-3
400 V
Accessories
BER..-4
VEM4
IEC
AC-3, 400 V
Rated Rated
power current
Control voltage
Uc min. ... Uc max.
kW
4
V 50/60 Hz V DC
24...60
20...60
48...130
48...130
AF09-30-10-12
100...250
100...250
AF09-30-10-13
250...500
250...500
AF09-30-10-14
24...60
20...60
48...130
48...130
AF12-30-10-12
100...250
100...250
AF12-30-10-13
250...500
250...500
AF12-30-10-14
24...60
20...60
48...130
48...130
AF16-30-10-12
100...250
100...250
AF16-30-10-13
250...500
250...500
AF16-30-10-14
24...60
20...60
48...130
48...130
AF26-30-00-12
100...250
100...250
AF26-30-00-13
250...500
250...500
AF26-30-00-14
24...60
20...60
48...130
48...130
AF30-30-00-12
100...250
100...250
AF30-30-00-13
250...500
250...500
AF30-30-00-14
24...60
20...60
48...130
48...130
AF38-30-00-12
100...250
100...250
AF38-30-00-13
250...500
250...500
AF38-30-00-14
5.5
7.5
11
15
18.5
A
8.5
11.5
15.5
22
29
35
Type
Order code
Setting
ranges
CA4-10
Type
Order code
Type
Order code
A ... A
7.60 ... 10.0
TF42-10
BER16-4
+
VEM4
TF42-13
BER16-4
+
VEM4
TF42-16
BER16-4
+
VEM4
TF42-24
TF42-35
BER38-4
+
VEM4
+
2x CA4-10
BER38-4
+
VEM4
+
2x CA4-10
BER38-4
+
VEM4
+
2x CA4-10
(1)
(1) For other control voltages, see "3-pole contactors - Ordering details" pages.
Setting ranges
Type
Order code
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
A ... A
0.10 ... 0.13
0.13 ... 0.17
0.17 ... 0.23
0.23 ... 0.31
0.31 ... 0.41
0.41 ... 0.55
0.55 ... 0.74
0.74 ... 1.00
1.00 ... 1.30
1.30 ... 1.70
1.70 ... 2.30
2.30 ... 3.10
3.10 ... 4.20
4.20 ... 5.70
5.70 ... 7.60
7.60 ... 10.0
10.0 ... 13.0
13.0 ... 16.0
16.0 ... 20.0
20.0 ... 24.0
24.0 ... 29.0
29.0 ... 35.0
35.0 ... 38.0/40.0
ABB | 29
1SBC100155C0202 ShortForm.indb 29
08/10/2010 12:29:44
Application
CE
Star-delta starting is the most common method to reduce the starting current of a motor.
This system can be used on all the squirrel cage motors, which are normally used in delta connection. In this type of
starting, it is recommended to choose motors having high starting torque i.e. much higher than the resistive torque
in order to reach sufficient high speed when the motor is connected in star.
When Starting:
I/In T/T
n
7
I = current
T = torque
In = nominal current
Tn = nominal torque
I (delta)
5
4
3
T (motor)
I (star)
2
1
T (motor)
Tr (resistive torque)
20
40
60
80
100
Precaution
Motor nominal voltage in delta connection must be equal to that of the mains. Example: a motor for 400 V stardelta starting must be designed for 400 V in "delta" connection. Its usual designation is "400 V / 690 V motor".
The motor must be constructed with 6 terminal windings
In order to prevent a high current peak, at least 85 % of nominal speed must be reached before switching from
star to delta
Sequence
Starting is a three-stage process:
1st stage: "Star" connection - Press the "On" button on the control circuit to close the KM2 "Star" contactor. The KM1
"line" contactor then closes and the motor starts. Countdown of programmed starting time (6 to 10 s) then begins.
2nd stage: "Star" to "Delta" switching - when programmed starting time is over, the KM2 "Star" contactor opens.
3rd stage: "Delta" connection - Thanks to AF contactors, a transition time (or dwelling time) of 50 ms is already
integrated between the opening of the "star" contactor and closing of the "delta" contactor.
Conclusion: An on-delay timer without dwelling time (e.g.: CT-ERS.21) is enough to countdown the programmed
starting time (6 to 10 s) during "Star connection". The use of a star-delta timer including a dwelling time is not
permitted.
690 V - 50/60 Hz
690 V
60 C (above 38 A 50 C)
Degree of protection
IP 20
Switching frequency
Mounting positions
Switching frequency/hour, according to acceleration time and load factor). Respect of the following
conditions enables utilization of the starter without
excessive overheating of the connections or
nuisance tripping of the thermal overload relay.
Example:
Switching frequency = 15 starts/hr
Motor starting time "Ta" = 7 s (use 8 s curve)
Maximum load factor = 63 %.
This corresponds to a 4-minute operating cycle (15
starts/hr) with 7 seconds acceleration, 2.5 minutes
operation and 1.5 minutes rest.
Pos. 1
Standards
70
60
Ta
=
50
40
5s
Ta =
8s
Ta =
10 s
30
Ta = 1
2s
20
Ta = 15
s
Ta = 20 s
10
0
10
20
30
40
50
60
70
80
90
100
30 | ABB
1SBC100155C0202 ShortForm.indb 30
08/10/2010 12:29:47
Description
You can easily assemble a star-delta starter thanks
to our complete range of accessories:
A2
On-delay timer
(optional)
A2
It includes:
- VM4 mechanical interlock unit and fixing clips
KM
Fixing
clip
KM
KM
AF...
Contactors
VM4
Mechanical
interlock unit
VE4
Electrical
interlock block
BEY..-4
Connection set
TF42
Thermal overload relay
Wiring Diagrams
Star-delta starter
KM3:5/L3
Us
96
STOP
.3
.3
KM1
KM1
.3
.3
.4
.4
KT1
A1
16
A2
KM2
(4)
KT1
15
A1
16
A2
(4)
6/T3
4/T2
2/T1
15
.4
.4
97
KM2
98
96
FR1
FR1
TEST
STOP
FR1
A
M
5/L3
.3
3/L2
1/L1
.4
6/T3
4/T2
2/T1
A1
6/T3
4/T2
2/T1
A2
KM2
A2
5/L3
3/L2
1/L1
A1
5/L3
.3
.4
6/T3
4/T2
2/T1
KM3
A
M
95
RESET
3/L2
A1
A2
1/L1
STOP
KM1
RESET
95
96
95
RESET
KM3:5/L3
Us
01
01
(2)
W1
V1
U1
W2
V2
U2
W1
V1
U1
W2
V2
U2
KM1
A1
KM3
A2
(1)
A2
A2
KM2
KM1
A1
KM3
A2
(2)
A2
(1)
A2
KM2
Us
N
Us
N
01
01
(2)
(2)
KM3:3/L2
(3)
AC or DC local control
KM3:3/L2
(3)
AC or DC remote control
ABB | 31
1SBC100155C0202 ShortForm.indb 31
08/10/2010 12:29:50
AC-3
400 V
Type
Order code
Type
Order code
Type
Order code
IEC
AC-3, 400 V
Rated Rated
power current
Control voltage
Uc min. ... Uc max.
kW
7.5
V 50/60 Hz V DC
24...60
20...60
AF09Z-30-10-21
AF09Z-30-10-21
AF09Z-30-10-21
48...130
48...130
AF09-30-10-12
AF09-30-10-12
AF09-30-10-12
100...250
100...250
AF09-30-10-13
AF09-30-10-13
AF09-30-10-13
250...500
250...500
AF09-30-10-14
AF09-30-10-14
AF09-30-10-14
24...60
20...60
AF12Z-30-10-21
AF12Z-30-10-21
AF09Z-30-10-21
48...130
48...130
AF12-30-10-12
AF12-30-10-12
AF09-30-10-12
100...250
100...250
AF12-30-10-13
AF12-30-10-13
AF09-30-10-13
250...500
250...500
AF12-30-10-14
AF12-30-10-14
AF09-30-10-14
24...60
20...60
AF16Z-30-10-21
AF16Z-30-10-21
AF09Z-30-10-21
48...130
48...130
AF16-30-10-12
AF16-30-10-12
AF09-30-10-12
100...250
100...250
AF16-30-10-13
AF16-30-10-13
AF09-30-10-13
250...500
250...500
AF16-30-10-14
AF16-30-10-14
AF09-30-10-14
24...60
20...60
AF26Z-30-00-21
AF26Z-30-00-21
AF26Z-30-00-21
48...130
48...130
AF26-30-00-12
AF26-30-00-12
AF26-30-00-12
100...250
100...250
AF26-30-00-13
AF26-30-00-13
AF26-30-00-13
250...500
250...500
AF26-30-00-14
AF26-30-00-14
AF26-30-00-14
24...60
20...60
AF26Z-30-00-21
AF26Z-30-00-21
AF26Z-30-00-21
48...130
48...130
AF26-30-00-12
AF26-30-00-12
AF26-30-00-12
100...250
100...250
AF26-30-00-13
AF26-30-00-13
AF26-30-00-13
250...500
250...500
AF26-30-00-14
AF26-30-00-14
AF26-30-00-14
24...60
20...60
AF30Z-30-00-21
AF30Z-30-00-21
AF26Z-30-00-21
48...130
48...130
AF30-30-00-12
AF30-30-00-12
AF26-30-00-12
100...250
100...250
AF30-30-00-13
AF30-30-00-13
AF26-30-00-13
250...500
250...500
AF30-30-00-14
AF30-30-00-14
AF26-30-00-14
11
15
18.5
22
25
A
15.5
22
29
35
41
47
S
ra
(1)
A
7
(1) For other control voltages, see "3-pole contactors - Ordering details" pages.
Note: an on-delay timer without dwelling-time (e.g.: CT-ERS.21 1SVR 630 100 R0300) is enough to countdown the programmed starting time during "Star connection".
32 | ABB
1SBC100155C0202 ShortForm.indb 32
08/10/2010 12:29:52
AC-3
400 V
Connection sets
Type
Order code
Setting
ranges
Type
Order code
Type
Order code
Type
Order code
A ... A
7.60 ... 10.0
TF42-10
BEY16-4
VEM4
TF42-13
BEY16-4
VEM4
TF42-20
BEY16-4
VEM4
TF42-24
BEY38-4
VEM4
KM1: 1 x CA4-10
KM2: 1 x CA4-10
TF42-24
BEY38-4
VEM4
KM1: 1 x CA4-10
KM2: 1 x CA4-10
TF42-29
BEY38-4
VEM4
KM1: 1 x CA4-10
KM2: 1 x CA4-10
Setting ranges
Type
Order code
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
A ... A
0.10 ... 0.13
0.13 ... 0.17
0.17 ... 0.23
0.23 ... 0.31
0.31 ... 0.41
0.41 ... 0.55
0.55 ... 0.74
0.74 ... 1.00
1.00 ... 1.30
1.30 ... 1.70
1.70 ... 2.30
2.30 ... 3.10
3.10 ... 4.20
4.20 ... 5.70
5.70 ... 7.60
7.60 ... 10.0
10.0 ... 13.0
13.0 ... 16.0
16.0 ... 20.0
20.0 ... 24.0
24.0 ... 29.0
29.0 ... 35.0
35.0 ... 38.0/40.0
ABB | 33
1SBC100155C0202 ShortForm.indb 33
08/10/2010 12:29:56
(mm, inches)
Direct-on-line Starters
77 3.03"
86 3.39"
5 0.20"
4.2 0.17"
10
0.39"
70 2.76"
5.5 0.22"
2x
M4 8-32 UNC
5 0.20"
5.5 0.22"
70 2.76"
60 2.36"
10
0.39"
35 1.38"
80 3.15"
5.5 0.22"
60 2.36"
4.2 0.17"
45 1.77"
35 mm EN/IEC 60715
156.1 6.15"
35 mm EN/IEC 60715
5.5 0.22"
2x
M4 8-32 UNC
158.9 6.26"
35 1.38"
5 0.20"
71 2.80"
45 1.77"
5 0.20"
6.2
0.24"
9.2
0.36"
72.7 2.86"
75.7 2.98"
76.8 3.02"
79.8 3.14"
Reversing Starters
102.5 4.04"
119.5 4.70"
90 3.54"
71 2.80"
35 mm EN/IEC 60715
70 2.76"
170 6.69"
4.2 0.17"
5.5 0.22"
80 3.15"
M4
10
0.39"
5 0.20"
60 2.36"
5.5 0.22"
5.5 0.22"
70 2.76"
2x
M4 8-32 UNC
80 3.15"
10
0.39"
166.5 6.56"
35 mm EN/IEC 60715
5.5 0.22"
80 3.15"
60 2.36"
90 3.54"
4.2 0.17"
5 0.20"
9.2
0.36"
6.2
0.24"
72.7 2.86"
75.7 2.98"
76.8 3.02"
79.8 3.14"
70 2.76"
4.2 0.17"
5 0.20"
22"
2x
M4 8-32 UNC
80 3.15"
10
0.39"
60 2.36"
2"
5 0.20"
75.7 2.98"
79.8 3.14"
34 | ABB
1SBC101127S0201.indd 34
14/10/2010 10:51:54
5 0.20"
102.5 4.04"
125 4.92"
4x
M4 8-32 UNC
35 1.38"
10
0.39"
70 2.76"
5.5 0.22"
166.5 6.55"
35 mm EN/IEC 60715
71 2.80"
4.2 0.17"
5 0.20"
135 5.31"
60 2.36"
Dimensions
5 0.20"
6.2
0.24"
72.7 2.86"
76.8 3.02"
119.5 4.70"
5.31"
80 3.15"
125 4.92"
2x
M4 8-32 UNC
70 2.76"
60 2.36"
5.5 0.22"
170
6.69"
35 mm EN/IEC 60715
10
0.39"
4.2 0.17"
5 0.20"
135
5 0.20"
9.2 0.36"
75.7 2.98"
79.8 3.14"
102.5 4.04"
71 2.80"
125 4.92"
70 2.76"
4.2 0.17"
5 0.20"
60 2.36"
5.5 0.22"
4x
M4 8-32 UNC
35 1.38"
10
0.39"
5 0.20"
ABB | 35
1SBC101128S0201.indd 35
14/10/2010 11:15:18
0.25 ... 15 kW
Short-circuit current Iq
16 kA - 50 kA
Coordination type
Type 1
Softstarters
36 | ABB
1SBC100155C0202 ShortForm.indb 36
08/10/2010 12:30:04
Application
Softstarters from PSR3 up to PSR30 are used for starting and stopping normal standard three phase motors. All
applications benefit from soft starting as it reduces the starting current and limits the mechanical stresses when
starting, giving the equipment a long life.
One of the most common applications is for the operation of pumps, where soft stopping can be used to avoid
water hammering and damage to pipes.
Other common applications are for starting fans, compressors, conveyors, mixers and tooling machines.
Description
PSR softstarters reduce the main voltage during-start using electronically-controlled semiconductors. The PSR
softstarters offer a very compact design thanks to the built-in by-pass contacts in the main circuit. Wide main
voltage range from 208 to 600 V limits the need of variants as well as being very robust and insensitive for voltage
variations. The range from 3 A up to 37 A is designed in three frame sizes. The compact design, clear marking and
limited need for control wiring makes it easy to install.
Types
MS116 + PSR16
The PSR range offers types with 24 V DC as well as a 100...240 V AC supply voltage.
The complete range has a run signal contact, while sizes PSR25 ... PSR30 also have a top of ramp signal (T.O.R.)
indicating the end of the start run. Each size of the PSR softstarters can be combined with our manual motor starters
(MMS) using the connection kits. This will result in a very compact starter combination.
Wiring Diagrams
L/+
L/+
N/-
N/-
MS116...132
MS116...132
L/+ N/-
L / + N /MS132
MS132
Mounting positions
PSR25...30
PSR25...30
ABB | 37
1SBC100155C0202 ShortForm.indb 37
08/10/2010 12:30:07
AC-53a
400 V
Connection Kit
Softstarter
I>
IEC
Type
Order code
AC-53a, 400 V
Rated Rated
power current
Current
setting
range
Magnetic Type
tripping
current
Order code
Aux.
Con./
ToR
0.25
0.85
0.63...1.00
11.5
PSR16-MS116
0.37
1.1
1.00...1.60
18.4
PSR16-MS116
0.75
1.1
1.5
2.2
3
4
5.5
7.5
1.5
1.9
2.7
3.6
4.9
6.5
8.5
11.5
15.5
1.00...1.60
1.60...2.50
2.50...4.00
2.50...4.00
4.00...6.30
18.4
28.75
50
50
78.75
6.30...10.00 150
6.30...10.00 150
8.00...12.00 180
10.00...16.00 240
Type
Order code
100...240
24
PSR3-600-70
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR3-600-70
V AC
50/60 Hz
kW
0.55
Control voltage
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
1
1
1
1
1
1
1
1
1
11
22
20...25
375
PSR30-MS132
1/1
15
29
25...32
480
PSR30-MS132
1/1
V DC
24
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR6-600-70
24
PSR6-600-81
100...240
PSR6-600-70
24
PSR6-600-81
100...240
PSR9-600-70
PSR9-600-81
24
100...240
24
100...240
24
100...240
24
100...240
24
Main Accessories
Type
Order code
PS-FBPA
PSR16-MS116
PSR30-MS132
PSR-FAN3-45A
38 | ABB
1SBC100155C0202 ShortForm.indb 38
08/10/2010 12:30:09
AC-53a
400 V
Connection Kit
Softstarter
I>
IEC
Type
Order code
AC-53a, 400 V
Rated Rated
power current
Current
setting
range
Magnetic Type
tripping
current
Order code
Aux.
Con./
ToR
0.25
0.85
0.63...1.00
11.5
PSR16-MS116
0.37
1.1
1.00...1.60
18.4
PSR16-MS116
0.75
1.1
1.5
2.2
3
4
5.5
7.5
1.5
1.9
2.7
3.6
4.9
6.5
8.5
11.5
15.5
1.00...1.60
1.60...2.50
2.50...4.00
2.50...4.00
4.00...6.30
18.4
28.75
50
50
78.75
6.30...10.00 150
6.30...10.00 150
8.00...12.00 180
10.00...16.00 240
Type
Order code
100...240
24
PSR3-600-70
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR3-600-70
V AC
50/60 Hz
kW
0.55
Control voltage
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
PSR16-MS116
1
1
1
1
1
1
1
1
1
11
22
20...25
375
PSR30-MS132
1/1
15
29
25...32
480
PSR30-MS132
1/1
V DC
24
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR3-600-70
24
PSR3-600-81
100...240
PSR6-600-70
24
PSR6-600-81
100...240
PSR6-600-70
24
PSR6-600-81
100...240
PSR9-600-70
PSR9-600-81
24
100...240
24
100...240
24
100...240
24
100...240
24
ABB | 39
1SBC100155C0202 ShortForm.indb 39
08/10/2010 12:30:12
108 4.25
24.2
0.951
108 4.25
70 2.76
5.5 0.22
72.4
2.85
237 9.33
45 1.77
237 9.33
DIN rail
35mm EN/IEC 60715
45 1.77
DIN rail
35mm EN/IEC 60715
25
5.5 0.22
81.3 3.2
75 [2.95]
75 [2.95]
80.1 3.15
45 1.77
45 1.77
MS116
MS116
+ PSR16-MS116 + PSR3 ... PSR16
+ PSR16-MS116
MS132-0.16
... MS132-10 + PSR16-MS116 + PSR3 ... PSR16
+ PSR16-MS116
+ PSR3 ... 16
+ PSR3 ... 16
75 [2.95]
124 4.88
240.9
259.4
10.21
DIN rail
35mm EN/IEC 60715
45 1.77
9.48
DIN rail
35mm EN/IEC 60715
72.2 2.84
30.9
1.218
5.5 0.22
72.2 2.84
45 1.77
5.5 0.22
27
1.062
75 [2.95]
107.8 4.24
81.1 3.19
81.1 3.19
45 1.77
45 1.77
MS132-12 ... MS132-32
MS132-12
... MS132-32 + PSR16-MS116 + PSR3 ... PSR16
+ PSR16-MS116
+ PSR3 ... 16
MS132-12
... MS132-32 + PSR30-MS132 + PSR25 ... PSR30
+ PSR30-MS132
+ PSR25 ... 30
40 | ABB
1SBC100155C0202 ShortForm.indb 40
08/10/2010 12:30:14
ABB | 41
1SBC100155C0202 ShortForm.indb 41
08/10/2010 12:30:25
Appli_Convoyer
42 | ABB
1SBC100155C0202 ShortForm.indb 42
08/10/2010 12:30:31
NF Contactor Relays
Overview ................................................................................................................................ 77
Ordering Details ........................................................................................................................ 78
Main Technical Data.................................................................................................................. 79
Main Accessory Fitting Details .................................................................................................. 80
Main Accessory Ordering Details .............................................................................................. 81
Dimensions............................................................................................................................... 82
PSR Softstarters
Main Technical Data.................................................................................................................. 85
Main Accessory Ordering Details .............................................................................................. 86
Dimensions............................................................................................................................... 87
1SBC101089S0201
ABB | 43
1SBC100155C0202 ShortForm.indb 43
08/10/2010 12:30:38
MS116
(0.10 ... 16 A)
MS132
(0.10 ... 32 A)
Main Accessories
PS1-..-65
3-phase busbar
up to 65 A
S1-M1-25
PS1-..-65
3-phase busbar
up to 100 A
S1-M3-35
BS1-3
HK1
PS1-..-100
SK1
BS1-3
HK1
HK1
SK1
CK1
SA1
MS116
AA1
HK1
CK1
MS132
HKF1-11
UA1
44 | ABB
1SBC100155C0202 ShortForm.indb 44
08/10/2010 12:30:41
Manual Motor
Starters
MS116
Certifications and approvals
cULus
CCC
GOST
GOST-FIRE BV
GL
LR
MS132
DNV
ABS
RMRS
CE
cULus
9.75 ... 15 x In
CCC
GOST
GOST-FIRE
GL
LR
yes
ON/OFF
ON/OFF/TRIP
yes
yes
Width
Setting range
Rated operational voltage Ue
Rated frequency
Trip class
Short-circuit breaking capacity Ics
Ambient air temperature open compensated
400 V
ABS
Rina
CE
9.75 ... 15 x In
yes
DNV
yes
yes
45 mm
45 mm
0.1 ... 16 A
0.1 ... 32 A
690 V AC
690 V AC
50 Hz / 60 Hz
50 Hz / 60 Hz
10A
10
up to 50 kA
up to 100 kA
Main Accessories
Front mounting
HKF1
Side mounting
HK1
Tripped alarm
SK1
Auxiliary
contacts
Signaling
contacts
Short-circuit alarm
CK1
Shunt trip
AA1
Undervoltage release
UA1
3-phase busbar
PS1
Feeder terminals
S1
Auxiliary
trip units
Busbar
systems
ABB | 45
1SBC100155C0202 ShortForm.indb 45
08/10/2010 12:30:48
Application
cULus
CCC
BV
GL
CE
GOST GOST-FIRE
LR
DNV
ABS
RMRS
Short-circuit protection
Overload protection
Trip class 10A
Phase loss sensitivity
ON/OFF switching functionality
Disconnecting feature
Suitable for three- and single phase applications
Description
45 mm width
One range of common accessories for MS116 & MS132
Ordering Details
MS116
Rated
power
400 V
AC-3
kW
0.03
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
4
5.5
7.5
Setting
ranges
A ... A
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
Type
Order code
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
Short-circuit
breaking
capacity
Ics at 400 V AC
Rated
instantaneous
short-circuit
current setting
kA
50
50
50
50
50
50
50
50
50
50
25
16
A
1.25 ... 1.87
1.95 ... 2.92
3.12 ... 4.68
4.91 ... 7.37
9.20 ... 13.8
14.7 ... 22.1
23.0 ... 34.5
40.0 ... 60.0
63.0 ... 94.5
120 ... 180
144 ... 216
192 ... 288
Pack(ing) Weight
pieces
kg
1
1
1
1
1
1
1
1
1
1
1
1
(1 pce)
0.225
0.225
0.225
0.225
0.225
0.265
0.265
0.265
0.265
0.265
0.265
0.265
A ... A
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
230 V AC
Icu
kA
Ics
kA
Maximum rated current of the back-up fuses if Icc > Ics (1)
400 V AC
440 V AC
500 V AC
gG, aM Icu
Ics
kA
kA
gG, aM Icu
kA
Ics
kA
gG, aM Icu
25
16
80
80
25
16
25
16
690 V AC
gG, aM Icu
kA
Ics
kA
gG, aM
5
2
2
2
2
2
25
25
40
50
50
63
25
16
kA
Ics
kA
80
80
10
6
6
6
6
4
10
6
6
6
6
4
25
25
63
63
63
63
10
6
6
6
6
4
10
6
6
6
6
4
25
25
63
63
63
63
5
2
2
2
2
2
45 1.77"
5.5 0.22"
35 mm EN/IEC 60715
90 3.54"
45 1.77"
46 | ABB
1SBC100155C0202 ShortForm.indb 46
08/10/2010 12:30:52
General data
Conformity to standards
yes
Disconnecting feature
yes
Mounting position
Position 1-6
Degree of protection
IP 20
Mechanical durability
100000 cycles
Electrical durability
100000 cycles
Utilization category
IEC
Rated operational voltage Ue
690 V AC
up to 16 A
Rated frequency
50 / 60 Hz
Trip class
10A
Isolation data
6 kV
690 V
Environmental
data
Main circuit
Operation
Open - compensated
Open
Enclosed (IB132)
0 ... +40 C
Storage
Connecting
capacity
Vibration
Shock
5 g / 3-150 Hz
25 g / 11 ms
Rigid
1 or 2 x
1 ... 4 mm
1 or 2 x
1 or 2 x
Stripping length
9 mm
Tightening torque
UL/CSA
Main circuit
600 V AC
480 V AC
0.16 A Ie 2.5 A
30 kA
2.5 A < Ie 16 A
18 kA
600 V AC
Connecting
capacity
5 kA
Stranded
1 or 2 x
AWG 16 ... 12
1 or 2 x
AWG 16 ... 12
Stripping length
9 mm
Tightening torque
10 lb.in
ABB | 47
1SBC100155C0202 ShortForm.indb 47
08/10/2010 12:30:53
Application
cULus
CCC
GL
LR
CE
GOST GOST-FIRE
DNV
ABS
Rina
Short-circuit protection
Overload protection
Trip class 10
Phase loss sensitivity
ON/OFF switching functionality
Disconnecting feature
Suitable for three- and single phase applications
Description
45 mm width
Lockable handle
Clear position of the handle ON/OFF/TRIP
Magnetic tripping optically signalled in the front
One range of common accessories for MS116 & MS132
Ordering Details
MS132-10
MS132-32
Rated
power
400 V
AC-3
kW
0.03
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
4
5.5
7.5
9
12.5
15
Setting
ranges
A ... A
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
16.0 ... 20.0
20.0 ... 25.0
25.0 ... 32.0
Type
Order code
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.6
MS132-2.5
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-20
MS132-25
MS132-32
Short-circuit
breaking
capacity Ics
at 400 V AC
kA
100
100
100
100
100
100
100
100
100
100
100
100
100
50
25
Rated
instantaneous
short-circuit
current setting
A
1.25 ... 1.87
1.95 ... 2.92
3.12 ... 4.68
4.91 ... 7.37
9.20 ... 13.8
14.7 ... 22.1
23.0 ... 34.5
40.0 ... 60.0
63.0 ... 94.5
120 ... 180
144 ... 216
192 ... 288
240 ... 360
300 ... 450
384 ... 576
Pack(ing) Weight
pieces
kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(1 pce)
0.215
0.215
0.215
0.215
0.215
0.265
0.265
0.265
0.265
0.265
0.310
0.310
0.310
0.310
0.310
A ... A
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
16.0 ... 20.0
20.0 ... 25.0
25.0 ... 32.0
Maximum rated current of the back-up fuses if Icc > Ics (1)
230 V AC
400 V AC
Ics
gG, aM
Icu
Ics
gG, aM
Icu
kA
A
kA
kA
A
kA
Icu
kA
690 V AC
Ics
gG, aM
kA
A
50
50
50
25
100
125
50
50
50
25
100
125
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
81.3 3.20"
97.8 3.85"
5.5 0.22"
43.3 1.70"
45 1.77"
45 1.77"
43.5 1.71"
45 1.77"
5.5 0.22"
35 mm EN/IEC 60715
90 3.54"
45 1.77"
81.1 3.19"
72.2 2.84"
72.4 2.85"
35 mm EN/IEC 60715
48 | ABB
1SBC100155C0202 ShortForm.indb 48
08/10/2010 12:30:58
up to 10 A
Standards
General data
up to 16 A
up to 32 A
Conformity to standards
Phase loss sensitivity
yes
Disconnecting feature
yes
Position 1-6
Mounting position
Degree of protection
IP 20
Mechanical durability
100000 cycles
Electrical durability
50000 cycles
Utilization category
IEC
Main circuit
Isolation data
AC
690 V AC
DC
250 V DC
up to 10 A
10 kA
Rated frequency
DC, 50 / 60 Hz
Trip class
6 kV
690 V
Environmental
data
up to 32 A
10
Open - compensated
Open
Enclosed (IB132)
0 ... +40 C
Storage
Connecting
capacity
up to 16 A
Vibration
5 g / 3-150 Hz
Shock
25 g / 11 ms
Rigid
1 or 2 x
1 ... 4 mm
1 ... 4 mm
2.5 ... 6 mm
1 or 2 x
1 ... 6 mm
1 or 2 x
1 ... 6 mm
9 mm
10 mm
10 mm
1.5 Nm
2.0 Nm
600 V AC
480 V AC
30 kA
600 V AC
Connecting
capacity
18 kA
Stranded
1 or 2 x
AWG 16 ... 12
AWG 16 ... 12
AWG 12 ... 8
1 or 2 x
AWG 16 ... 12
AWG 16 ... 12
AWG 12 ... 8
Stripping length
9 mm
10 mm
10 mm
Tightening torque
10 ... 12 lb.in
14 lb.in
18 lb.in
ABB | 49
1SBC100155C0202 ShortForm.indb 49
08/10/2010 12:31:00
MS1
Dato
Auxiliary contacts
Manual Motor Starters
Aux. contacts
MS116
N.O.
MS132
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
HKF1-11
10
0.016
2
2
2
0.035
0.035
0.035
N.C.
1
2
0
HK1-11
HK1-20
HK1-02
Auxiliary contacts with lead contacts, mountable on the right, also to use with undervoltage release
0
0.035
2
2
2
0.035
0.035
0.035
2
2
2
0.035
0.035
0.035
Order code
Pack(ing) Weight
pieces kg (1 pce)
AA1-24
AA1-110
AA1-230
AA1-400
1
1
1
1
0.100
0.100
0.100
0.100
UA1-24
UA1-48
UA1-60
UA1-120
UA1-208
UA1-230
UA1-400
UA1-415
1
1
1
1
1
1
1
1
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
HK1-20L
Signaling contacts
Signaling contacts for tripped alarm, mountable on the right
HK1-11
1
2
0
1
2
0
1
0
2
SK1-11
SK1-20
SK1-02
SK1-11
1
0
2
CK1-11
CK1-20
CK1-02
MS132
24 V 50/60 Hz
110 V 50/60 Hz
200 ... 240 V 50/60 Hz
350 ... 415 V 50/60 Hz
24 V 50 Hz
48 V 50 Hz
60 V 50 Hz
110 V 50 Hz - 120 V 60 Hz
208 V 60 Hz
230 V 50 Hz - 240 V 60 Hz
400 V 50 Hz
415 V 50 Hz - 480 V 60 Hz
AA1
UA1
HK1
SK1
HK1
SK1
HK1
HK1
MS116
SK1
HK1
AA1
HK1
CK1
MS132
CK1
HKF1-11
AA1
UA1
HKF1-11
C1
AA1-..
D1
UA1-..
D2
41
55
65
32
42
56
66
HK1-02
C2
U<
31
1 L1 3 L2 5 L3
2 T1 4 T2 6 T3
43
57
67
34
44
58
68
21
33
41
57
65
14
22
34
42
58
66
HK1-11
AA1-..
D1
SK1-11
UA1-..
HKF1
HK1
SK1
CK1
AA1
UA1
D2
31
41
55
65
75
85
32
42
56
66
76
86
HK1-02
C2
U<
SK1-20
13
HKF1-11
I> I> I>
C1
SK1-02
33
HK1-20
UA1
1 L1 3 L2 5 L3
SK1-02
CK1-02
33
43
57
67
77
87
34
44
58
68
78
88
HK1-20
SK1-20
CK1-20
13
21
33
41
57
65
77
85
14
22
34
42
58
66
78
86
HKF1-11
HK1-11
SK1-11
CK1-11
2 T1 4 T2 6 T3
50 | ABB
1SBC101093S0202.indd 50
15/04/2011 16:36:50
Number of
aux. contacts
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
0
0
0
0
1
1
1
1
2
2
2
2
PS1-2-0-65
PS1-3-0-65
PS1-4-0-65
PS1-5-0-65
PS1-2-1-65
PS1-3-1-65
PS1-4-1-65
PS1-5-1-65
PS1-2-2-65
PS1-3-2-65
PS1-4-2-65
PS1-5-2-65
10
10
10
10
10
10
10
10
10
10
10
10
0.034
0.055
0.077
0.098
0.036
0.060
0.087
0.108
0.040
0.067
0.095
0.122
0
0
0
1
1
1
2
PS1-3-0-100
PS1-4-0-100
PS1-5-0-100
PS1-3-1-100
PS1-4-1-100
PS1-5-1-100
PS1-3-2-100
10
10
10
10
10
10
10
0.084
0.117
0.154
0.094
0.134
0.172
0.105
Rated cross
section
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
25 mm
25 mm
S1-M1-25
S1-M2-25
10
10
0.038
0.051
S1-M3-25
S1-M3-35
10
10
0.042
0.060
BS1-3
50
0.003
Type
Order code
Pack(ing) Weight
pieces kg (1 pce)
10
10
10
3-phase busbar up to 65 A
PS1-..-65
PS1-..-100
2
3
4
5
2
3
4
5
2
3
4
5
3
4
5
3
4
5
3
S1-M1-25
S1-M2-25
Remarks
100 A
Flat
High
S1-M3-25
100 A
25 mm
35 mm
Locking
Manual Motor Starters
MS116
MS132
Locking device
SA1
3-phase busbar up to 65 A
0.003
0.020
0.050
S1-M2-25
PS1-..-100
PS1-..-65
S1-M1-25
BS1-3
MS132
BS1-3
PS1-..-65
MS132
MS116
MS116
SA1
MS132
ABB | 51
1SBC101093S0202.indd 51
15/04/2011 16:36:57
Enclosures IP65
Padlockable max. 3 padlocks with bail diameter 46.5
Manual Motor Starters
MS116
MS132
Color
Type
Order code
Yellow/red
Grey/black
IB132-Y
IB132-G
Pack(ing) Weight
pieces kg (1 pce)
1
0.370
1
0.370
IB132-Y
Color
Type
Order code
Yellow/red
Grey/black
DMS132-Y
DMS132-G
Pack(ing) Weight
pieces kg (1 pce)
1
0.170
1
0.170
MS132
IB132-G
DMS132-Y
DMS132-G
119 4.69"
135.7 5.34"
121 4.76"
174 6.85"
194 7.64"
183 7.2"
24 .94"
I ON
I ON
0
OFF
92 3.62"
0
OFF
116.15 4.57"
52 | ABB
1SBC101093S0202.indd 52
15/04/2011 16:37:01
Shafts
For selector type handles. Shaft diameter 6 mm. Shaft extension for door coupling driver.
Manual Motor Starters
Shaft lenght
Type
Order code
MS116
MS132
mm
85
105
130
180
OXS6X85
OXS6X105
OXS6X130
OXS6X180
Pack(ing) Weight
pieces kg (1 pce)
1
0.020
1
0.020
1
0.030
1
0.040
MSHD-LB
Color
Type
Order code
Black
Yellow
Black
Yellow
MSHD-LB (1)
MSHD-LY (1)
MSHD-LTB (2)
MSHD-LTY (2)
MS132
Pack(ing) Weight
pieces kg (1 pce)
1
0.065
1
0.065
1
0.065
1
0.065
Driver
Coupling driver for use with 6 mm OXS6 types up to 180 mm.
Manual Motor Starters
MS116
MSMN
Type
Order code
MSMN (1)
MSMNO (2)
MS132
Pack(ing) Weight
pieces kg (1 pce)
1
0.002
1
0.002
Driver shafts
Driver shaft - combination driver & shaft. Shaft diameter 6 mm.
MSOX-30
Shaft lenght
Type
Order code
MS116
mm
32
30
MSOX-32
MSOX-30
MS132
Pack(ing) Weight
pieces kg (1 pce)
1
0.010
1
0.010
Main Di
ABB | 53
1SBC101093S0202.indd 53
15/04/2011 16:37:03
80.1 3.15"
81 3.19"
70 2.76"
85.6 3.37"
9 0.35"
57.8 2.28"
9 0.35"
90 3.54"
90 3.54"
MS116
43.5 1.71"
45 1.77"
5.5 0.22"
35 mm EN/IEC 60715
45 1.77"
18 0.71"
MS116
+ UA1, AA1, SK1, HK1, HKF1-11
54 | ABB
1SBC100155C0202 ShortForm.indb 54
08/10/2010 12:31:30
81.1 3.19"
81.3 3.20"
72.4 2.85"
5.5 0.22"
18 0.71"
86.5 3.41"
57.8 2.28"
90 3.54"
45 1.77"
35 mm EN/IEC 60715
9 0.35"
45 1.77"
90 3.54"
45 1.77"
43.5 1.71"
97.8 3.85"
5.5 0.22"
35 mm EN/IEC 60715
45 1.77"
72.2 2.84"
81 3.19"
43.3 1.70"
9 0.35"
81.1 3.19"
81 3.19"
72.2 2.84"
18 0.71"
43.3 1.70"
86.5 3.41"
9 0.35"
57.8 2.28"
9 0.35"
45 1.77"
97.8 3.85"
45 1.77"
71"
5.5 0.22"
35 mm EN/IEC 60715
45 1.77"
97.8 3.85"
81.3 3.20"
72.4 2.85"
ABB | 55
1SBC100155C0202 ShortForm.indb 55
08/10/2010 12:31:32
for Contactors
CAT4-11
2-pole auxiliary contact
and A1/A2 coil terminal block
BX4-CA
Protective cover
VM4
BX4-CA
Protective cover
CA4
4-pole auxiliary
contact block
A2
A2
CA4, CC4
1-pole auxiliary
contact block
CAL4-11
2-pole auxiliary
contact block
Top or bottom
mounted
coil terminal block
BX4
Protective cover
VM4
BB4
Fixing clips
VE4
Reversing Starter
Star-Delta Starter
VEM4
mechanical &
electrical
interlock set
VEM4
mechanical &
electrical
interlock set
Main Accessories
Fixing clips
56 | ABB
1SBC100155C0202 ShortForm.indb 56
08/10/2010 12:32:07
3-pole Contactors
AC / DC control voltage
AF09
AF12
AF16
AF26
AF30
AF38
IEC
AC-3
UL/CSA
Rated
operational
current
400 V
60 C
400 V
60 C
415 V
60 C
690 V
480 V
Motor rating
NEMA size
4 kW
9A
9A
7A
5 hp
00
5.5 kW
12 A
12 A
9A
7.5 hp
0
7.5 kW
18 A
18 A
10.5 A
10 hp
-
11 kW
26 A
26 A
17 A
15 hp
1
15 kW
32 A
32 A
21 A
20 hp
-
18.5 kW
38 A
38 A
24 A
20 hp
-
setting range in A
0.10 ... 0.13 0.23 ... 0.31 0.55 ... 0.74 1.30 ... 1.70 3.10 ... 4.20 7.60 ... 10.0 16.0 ... 20.0 29.0 ... 35.0
0.13 ... 0.17 0.31 ... 0.41 0.74 ... 1.00 1.70 ... 2.30 4.20 ... 5.70 10.0 ... 13.0 20.0 ... 24.0 35.0 ... 38.0
0.17 ... 0.23 0.41 ... 0.55 1.00 ... 1.30 2.30 ... 3.10 5.70 ... 7.60 13.0 ... 16.0 24.0 ... 29.0
EF19...
EF45...
setting range in A
setting range in A
0.30 ... 1.00 0.80 ... 2.70 1.90 ... 6.30 5.70 ... 18.9
9.00 ... 30.0
IEC
AC-1
Rated
operational
current
40 C
690 V
60 C
690 V
70 C
690 V
UL/CSA
600 V AC
25 A
25 A
22 A
4 mm2
25 A
AWG 10
28 A
28 A
24 A
6 mm2
28 A
AWG 10
30 A
30 A
26 A
6 mm2
30 A
AWG 10
45 A
40 A
32 A
10 mm2
45 A
AWG 8
50 A
42 A
37 A
10 mm2
50 A
AWG 8
50 A
42 A
37 A
10 mm2
50 A
AWG 8
Main Accessories
1-pole CA4-10 or CA4-01, CC4-10 or CC4-01
Auxiliary
contact
blocks
4-pole CA4
Front mounting
Side mounting
Mechanical / electrical
VEM4
including VM4 mechanical interlock unit and VE4 electrical interlock block with A2-A2 connection
Interlocks
VM4
Mechanical
Reversing Starters
BER16-4
BER38-4
Star-Delta Starters
BEY16-4
BEY38-4
Connection
sets
ABB | 57
1SBC100155C0202 ShortForm.indb 57
08/10/2010 12:32:18
4 to 18.5 kW
5 to 20 hp
Application
cULus
CCC
GOST
C-Tick
CE
AF09 ... AF38 contactors are used for controlling power circuits up to 690 V AC and 220 V DC.
They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.
Description
AF09 ... AF38 contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max.
Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC
AF contactors can manage large control voltage variations. One coil (e.g. 100...250 V 50/60 Hz - DC) can be
used for different control voltages used worldwide without any coil change
AF..Z contactors equipped with a Z coil type allow direct control by 24 V DC 500 mA PLC-output and obtain a
reduced holding coil consumption.
AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance)
AF contactors have built-in surge protection and do not require additional surge suppressors
The built-in N.C. auxiliary contact is a mirror contact in compliance with annex F of IEC 60947-4-1.
Ordering Details
AF09-30-10
IEC
UL/CSA
Control voltage
Rated
power
400 V
AC-3
kW
4
3-phase
motor
rating
480 V
hp
5
5.5
7.5
7.5
10
11
15
15
20
18.5
20
AF26-30-00
V 50/60 Hz
24...60
24...60
48...130
48...130
100...250
100...250
250...500
250...500
24...60
24...60
48...130
48...130
100...250
100...250
250...500
250...500
24...60
24...60
48...130
48...130
100...250
100...250
250...500
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
V DC
20...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
20...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
20...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
Auxiliary Type
contacts
fitted
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
AF09Z-30-10-21
AF09Z-30-01-21
AF09-30-10-12
AF09-30-01-12
AF09-30-10-13
AF09-30-01-13
AF09-30-10-14
AF09-30-01-14
AF12Z-30-10-21
AF12Z-30-01-21
AF12-30-10-12
AF12-30-01-12
AF12-30-10-13
AF12-30-01-13
AF12-30-10-14
AF12-30-01-14
AF16Z-30-10-21
AF16Z-30-01-21
AF16-30-10-12
AF16-30-01-12
AF16-30-10-13
AF16-30-01-13
AF16-30-10-14
AF16-30-01-14
AF26Z-30-00-21
AF26-30-00-12
AF26-30-00-13
AF26-30-00-14
AF30Z-30-00-21
AF30-30-00-12
AF30-30-00-13
AF30-30-00-14
AF38Z-30-00-21
AF38-30-00-12
AF38-30-00-13
AF38-30-00-14
Order code
Weight
Pack(ing)
1 piece
kg
0.310
0.310
0.270
0.270
0.270
0.270
0.310
0.310
0.310
0.310
0.270
0.270
0.270
0.270
0.310
0.310
0.310
0.310
0.270
0.270
0.270
0.270
0.310
0.310
0.350
0.310
0.310
0.350
0.350
0.310
0.310
0.350
0.350
0.310
0.310
0.350
10 0.39"
70 2.76"
5.5 0.22"
5 0.20"
35 1.38"
80 3.15"
4.2 0.17"
5.5 0.22"
5.5 0.22"
10 0.39"
58 | ABB
1SBC101060S0202.indd 58
15/04/2011 12:58:14
2x
M4 8-32
70 2.76"
6 0.24"
4.2 0.17"
80
60 3.15"
2.36"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
86 3.39"
2x
M4 8-32 UNC
5 0.20"
5 0.20"
1.77"
3545
1.38"
60 2.36"
71 2.80"
35 mm EN/IEC 60715
77 3.03"
45 1.77"
5 0.20"
4 to 18.5 kW
5 to 20 hp
AF09
Standards
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14
Main poles
IEC
690 V
25 ... 400 Hz
AF12
AF16
AF26
AF30
AF38
9A
12 A
18 A
26 A
32 A
38 A
2.2 kW
3 kW
4 kW
6.5 kW
9 kW
11 kW
380-400 V
4 kW
5.5 kW
7.5 kW
11 kW
15 kW
18.5 kW
415 V
4 kW
5.5 kW
9 kW
11 kW
15 kW
18.5 kW
440 V
4 kW
5.5 kW
9 kW
15 kW
18.5 kW
22 kW
500 V
5.5 kW
7.5 kW
9 kW
15 kW
18.5 kW
22 kW
690 V
5.5 kW
7.5 kW
9 kW
15 kW
18.5 kW
22 kW
380-400 V
220-230-240 V
40 C
25 A
28 A
30 A
45 A
50 A
50 A
60 C
25 A
28 A
30 A
40 A
42 A
42 A
70 C
22 A
24 A
26 A
32 A
37 A
37 A
4 mm
6 mm
6 mm
10 mm
10 mm
10 mm
12 A
16 A
22 A
30 A
40 A
50 A
UL/CSA
600 V
440-480 V
5 hp
7.5 hp
10 hp
15 hp
20 hp
20 hp
600 V AC
25 A
28 A
30 A
45 A
50 A
50 A
AWG 10
AWG 10
AWG 10
AWG 8
AWG 8
AWG 8
Ambient air
temperature
Operation
close to contactor
Storage
Magnet system
DC supply
AC
control voltage
50/60 Hz
DC
control voltage
24 ... 500 V AC
Coil consumption
(AF) 50 VA - (AF..Z) 16 VA
20 ... 500 V DC
PLC-output control
(AF..Z) 500 mA 24 V DC
Coil consumption
Electromagnetic compatibility
Built-in auxiliary contacts
IEC
UL/CSA
24 V DC
Pilot duty
Coil or built-in
auxiliary
contact
terminals
3A
6 A / 144 W
A600, Q600
Rigid
1 or 2 x
1 ... 6 mm
2.5 ... 10 mm
1 or 2 x
0.75 ... 6 mm
1.5 ... 10 mm
1 or 2 x
AWG 16 ... 10
AWG 14 ... 8
Tightening torque
1.5 Nm / 13 lb.in
2.5 Nm / 22 lb.in
Stripping length
10 mm
14 mm
Degree of protection
690 V
Rigid
1 or 2 x
1 ... 2.5 mm
1 or 2 x
1 or 2 x
AWG 18 ... 14
1.2 Nm / 11 lb.in
Stripping length
10 mm
IP20
ABB | 59
1SBC100155C0202 ShortForm.indb 59
08/10/2010 12:32:23
Main
poles
Built-in
auxiliary
contacts
Front-mounted accessories
Side-mounted accessories
(between 2 contactors)
1-pole CA4
Left side
1-pole CC4
2-pole CAT4-11
4-pole CA4
Right side
2-pole CAL4-11
VEM4
Max. N.C. built-in and add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 30, 5
3 0
0 1
3 0
1 0
3 0
0 0
4 max.
or 1
or 1
+ 1
2 max.
+ 1
+ 1
or 1
3 max.
+ 1
+ 1
4 max.
or 1
or 1
+ 1
2 max.
or 1
+ 1
+ 1
3 max.
+ 1
+ 1
or 1
Mounting positions
Pos. 2
+30
-30
Pos. 4
Pos. 3
Pos. 1
Pos. 1 30
Pos. 5
AF contactor
Fixing clips
A2
A2
AF contactor
2-pole CAT4-11
VM4
1-pole
CA4, CC4
4-pole CA4
2-pole CAL4-11
1-pole CA4, CC4
VE4
2-pole CAL4-11
1-pole
CA4, CC4
TF42
EF..
TF42
EF..
60 | ABB
1SBC100155C0202 ShortForm.indb 60
08/10/2010 12:32:26
Ordering Details
For contactors
Auxiliary contacts
Type
Order code
Pack(ing) Weight
pieces
kg (1 pce)
CAL4-11
CA4-22E
CAT4-11E
1
1
0
0
2
3
1
0
2
3
4
0
4
3
2
0
0
1
1
2
1
3
4
2
1
0
4
0
1
2
CA4-10
CA4-10-T
CA4-01
CA4-01-T
CA4-22M
CA4-31M
CA4-13M
CA4-04M
CA4-22E
CA4-31E
CA4-40E
CA4-04E
CA4-40U
CA4-31U
CA4-22U
1
10
1
10
1
1
1
1
1
1
1
1
1
1
1
0.014
0.014
0.014
0.014
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
AF09 ... AF38
- - -
1 0
0 1
CC4-10
CC4-01
1
1
0.014
0.014
1
10
0.040
0.040
1 1
1 1
- - -
CAL4-11
CAL4-11-T
VEM4
01 NC
01NC
1 1
1 1
1 1
- - - -
CAT4-11M
CAT4-11E
CAT4-11U
1
1
1
0.040
0.040
0.040
VM4
10
0.005
0.035
50
0.002
BEA16-4
BEA26-4
10
10
0.025
0.025
BEA38-4
10
0.030
BER16-4
BER38-4
1
1
0.045
0.100
BEY16-4
BEY38-4
1
1
0.050
0.110
LDC4
10
0.010
BX4
BX4-CA
10
50
0.006
0.001
Interlocks
KM1
A2
KM2
A2
VEM4
Note: VM4 includes 2 fixing clips (BB4) to maintain together both contactors.
1 1
- -
VEM4
Note: VEM4 includes a VM4 mechanical interlock unit with 2 fixing clips (BB4), a VE4 electrical interlock block.
VE4 block must be used with A2-A2 connection to respect the electrical connection diagram.
Fixing clips
AF09 ... AF38
BEA16-4
BB4
BER16-4
Protective covers
BX4
BX4-CA
ABB | 61
1SBC100155C0202 ShortForm.indb 61
08/10/2010 12:32:31
10 0.39"
70 2.76"
2x
M4 8-32 UNC
10 0.39"
5 0.20"
80 3.15"
4.2 0.17"
5 0.20"
5.5 0.22"
35 1.38"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
35 1.38"
4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
6 0.24"
35 mm EN/IEC 60715
80 3.15"
5 0.20"
110.5 4.35"
71 2.80"
45 1.77"
77 3.03"
10 0.39"
12 0.47"
71 2.80"
45 1.77"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
80 3.15"
6 0.24"
80 3.15"
5.5 0.22"
60 2.36"
71 2.80"
5.5 0.22"
5 0.20"
77 3.03"
2.80"
45711.77"
45 1.77"
10 0.39"
102.5 4.04"
110.5 4.35"
71 2.80"
10 0.39"
45 1.77"
102.5 4.04"
4.2 0.17"
0.17"
5 4.2
0.20"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
80 3.15" 2 x
M4 8-32 UNC
5 0.20"
80 3.15"
70 2.76"
5.5 0.22"
10 0.39"
5.5 0.22"
60 2.36"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
91.5 3.60"
5.5 0.22"
102.5 4.04"
0.39"
71102.80"
5 0.20"
71 2.80"
60 2.36"
43 1.69"
90 3.54"
5 0.20"
62 | ABB
1SBC100155C0202 ShortForm.indb 62
08/10/2010 12:32:35
80 3.15"
5.5 0.22"
43 1.69"
90 3.54"
35 mm EN/IEC 60715
5.5 0.22"
10 0.39"
5.5 0.22"
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
71 2.80"
45 1.77"
4.2 0.17"
70 2.76"
10 0.39"
5 0.20"
10 0.39"
2x
M4 8-32 UNC
5 0.20"
5.5 0.22"
35 1.38"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
6 0.24"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
80 3.15"
35 1.38"
5.5 0.22"
5.5 0.22"
60 2.36"
71 2.80"
45 1.77"
80 3.15"
5 0.20"
86 3.39"
45 1.77"
5 0.20"
86 3.39"
119.5 4.70"
45 1.77"
80 3.15"
10 0.39"
12 0.47"
80 3.15"
45 1.77"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
111.5 4.39"
119.5 4.70"
10 0.39"
45 1.77"
35 mm EN/IEC 60715
80 3.15"
60 2.36"
43 1.69"
5.5 0.22"
60 2.36"
5.5 0.22"
4.2 0.17"
80 3.15" 2 x
M4 8-32 UNC
4.2 0.17"
5 0.20"
2x
M4 8-32 UNC
5 0.20"
10 0.39"
5.5 0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
111.5 4.39"
80 10
3.15"
0.39"
70 2.76"
80 3.15"
70 2.76"
111.5 4.39"
90 3.54"
5.5 0.22"
91.5 3.60"
5.5 0.22"
43 1.69"
90 3.54"
10 0.39"
5.5 0.22"
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
80 3.15"
43 1.69"
80 3.15"
5 0.20"
45 1.77"
5 0.20"
ABB | 63
1SBC100155C0202 ShortForm.indb 63
08/10/2010 12:32:37
CE
Overload protection
Trip class 10
Phase loss sensitivity
Manual/automatic reset selectable
Description
45 mm width
Suitable for contactor AF09 ... AF38
Sealable operating elements
Ordering Details
TF42
Setting ranges
Type
Order code
Max. fuse
A ... A
0.10 ... 0.13
0.13 ... 0.17
0.17 ... 0.23
0.23 ... 0.31
0.31 ... 0.41
0.41 ... 0.55
0.55 ... 0.74
0.74 ... 1.00
1.00 ... 1.30
1.30 ... 1.70
1.70 ... 2.30
2.30 ... 3.10
3.10 ... 4.20
4.20 ... 5.70
5.70 ... 7.60
7.60 ... 10.0
10.0 ... 13.0
13.0 ... 16.0
16.0 ... 20.0
20.0 ... 24.0
24.0 ... 29.0
29.0 ... 35.0
35.0 ... 38.0/40.0
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
A
0.5 T
1T
1T
1T
2 gG
2 gG
4 gG
6 gG
6 gG
10 gG
10 gG
10 gG
20 gG
20 gG
35 gG
35 gG
40 gG
40 gG
63 gG
63 gG
63 gG
80 gG
80 gG
Suitable for
contactors
Pack(ing)
pieces
Weight
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.145
0.145
0.145
0.145
kg
(1 pce)
80 3.15"
5.5 0.22"
4.2 0.17"
10
0.39"
5 0.20"
5 0.20"
9.2
0.36"
6.2
0.24"
72.7 2.86"
75.7 2.98"
76.8 3.02"
79.8 3.14"
64 | ABB
1SBC100155C0202 ShortForm.indb 64
08/10/2010 12:32:39
2x
M4 8-32 U
70 2.76"
5.5 0.22"
60 2.36"
35 mm EN/IEC 60715
70 2.76"
2x
M4 8-32 UNC
5 0.20"
60 2.36"
5.5 0.22"
4.2 0.17"
10
0.39"
158.9 6.26"
35 mm EN/IEC 60715
5.5 0.22"
156.1 6.15"
45 1.77"
35 1.38"
71 2.80"
5 0.20"
77 3.03"
45 1.77"
Isolation data
(acc. to IEC/EN 60947-1)
Environmental
data
Auxiliary circuit
Conformity to standards
Phase loss sensitivity
Mounting position
Degree of protection
24 V
110-120-125 V
250 V
500 V
Main circuit
Auxiliary circuit
UL/CSA
Main circuit
Connecting capacity
up to 20.0 A
up to 38.0/40.0 A
IEC/EN60947-1, IEC/EN60947-4-1, IEC/EN60947-5-1, UL 508, CSA C22.2 No. 14
Yes
Position 1
IP 20
Rigid
Flexible with ferrule
Flexible without ferrule
Stripping length
Tightening torque
Rigid
Flexible with ferrule
Flexible without ferrule
Stripping length
Tightening torque
Auxiliary circuit
Stranded
Flexible without ferrule
Stripping length
Tightening torque
Stranded
Flexible without ferrule
Stripping length
Tightening torque
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
690 V AC
up to 20.0 A
50 / 60 Hz
10
6 kV
690 V
up to 38.0/40.0 A (50 C)
AWG 14 ... 6
AWG 14 ... 6
22 lb.in
ABB | 65
1SBC100155C0202 ShortForm.indb 65
08/10/2010 12:32:40
CCC
CE
Overload protection
Trip class 10E, 20E, 30E
Phase loss sensitivity
Manual/automatic reset selectable
Description
45 mm width
Suitable for contactor AF09 ... AF38
Ordering Details
Setting ranges
Type
Order code
Max. fuse
Suitable for
contactors
gG
EF19
A ... A
Pack(ing)
pieces
Weight
kg
(1 pce)
EF19-0.32
EF19-1.0
EF19-2.7
EF19-6.3
EF19-18.9
1
4
10
20
50
1
1
1
1
1
0.158
0.158
0.158
0.158
0.158
160
160
1
1
0.362
0.362
EF45-30
EF45-45
EF45
77 3.03"
80 3.15"
5.5 0.22"
5.5 0.22"
35 mm EN/IEC 60715
10 0.39"
155.2 6.11"
35 mm EN/IEC 60715
5.5 0.22"
152.4 6.00"
45 1.77"
71 2.80"
45 1.77"
10 0.39"
5.5 0.22"
17.4 0.69"
20.4 0.80"
73.3 2.89"
76.3 3.00"
76.8 3.02"
79.8 3.14"
80 3.15"
10 0.39"
5.5 0.22"
172.3 6.78"
35 mm EN/IEC 60715
5.5 0.22"
82.5 3.25"
86 3.39"
66 | ABB
1SBC100155C0202 ShortForm.indb 66
08/10/2010 12:32:44
EF45
up to 18.9 A
up to 45.0 A
Conformity to standards
Phase loss sensitivity
EF19
Yes
any
Mounting position
Degree of protection
IP 20
IEC
Main circuit
Isolation data
690 V AC
up to 18.9 A
Rated frequency
50 / 60 Hz
Trip class
6 kV
690 V
Environmental
data
Open - compensated
Open
Storage
Auxiliary circuit
Vibration
1 g / 3-150 Hz
Shock
Rated operational voltage Ue
15 g / 11 ms
600 V
AC-15
110-120 V
220-230-240 V
400 V
480-500 V
DC-13
24 V
110-120-125 V
250 V
Connecting
capacity
up to 45.0 A
N.C.
3A
N.O.
3A
N.C.
3A
N.O.
3A
N.C.
1.1 A
N.O.
1.1 A
N.C.
0.75 A
N.O.
0.75 A
N.C.
1.5 A
N.O.
1.5 A
N.C.
0.55 A
N.O.
0.55 A
N.C.
0.27 A
N.O.
0.27 A
Rigid
1 or 2 x
1.0 ... 4 mm
2.5 ... 16 mm
1 or 2 x
2.5 ... 10 mm
1 or 2 x
2.5 ... 10 mm
Stripping length
9 mm
13 mm
Tightening torque
2.3... 2.5 Nm
Main circuit
Auxiliary circuit
Rigid
1 or 2 x
1 or 2 x
1 or 2 x
Stripping length
9 mm
Tightening torque
UL/CSA
Main circuit
Connecting
capacity
Main circuit
Auxiliary circuit
600 V AC
Stranded
1 or 2 x
AWG 16 ... 10
AWG 16 ... 6
1 or 2 x
AWG 16 ... 10
AWG 16 ... 6
Stripping length
9 mm
13 mm
Tightening torque
7 ... 13 lb.in
20 ... 22 lb.in
Stranded
1 or 2 x
AWG 18 ... 10
1 or 2 x
AWG 18 ... 10
Stripping length
9 mm
Tightening torque
7 ... 11 lb.in
ABB | 67
1SBC100155C0202 ShortForm.indb 67
08/10/2010 12:32:46
Appli_factory
68 | ABB
1SBC100155C0202 ShortForm.indb 68
08/10/2010 12:32:57
4-pole
Contactors
AC / DC control voltage
AF09
AF16
AF26
AF38
AF09-40-00
AF16-40-00
AF26-40-00
AF38-40-00
AF09-22-00
AF16-22-00
AF26-22-00
AF38-22-00
25 A
25 A
22 A
4 mm2
25 A
AWG 10
30 A
30 A
26 A
6 mm2
30 A
AWG 10
45 A
40 A
32 A
10 mm2
45 A
AWG 8
55 A
45 A
37 A
16 mm2
55 A
AWG 6
AC-1
IEC
Rated
operational
current
40 C
690 V
60 C
690 V
70 C
690 V
UL/CSA
600 V AC
Main Accessories
1-pole CA4-10 or CA4-01, CC4-10 or CC4-01
4-pole CA4
Front mounting
Auxiliary
contact
blocks
Side mounting
VEM4
Mechanical / electrical
including VM4 mechanical interlock unit and VE4 electrical interlock block with A2-A2 connection
Interlocks
VM4
Mechanical
Fixing clips
CAT4-11
2-pole auxiliary contact
and A1/A2 coil terminal block
BX4-CA
Protective cover
VM4
A2
BX4-CA
Protective cover
CA4
4-pole auxiliary
contact block
A2
CA4, CC4
1-pole auxiliary
contact block
CAL4-11
2-pole auxiliary
contact block
Top or bottom
mounted
coil terminal block
BX4
Protective cover
BB4
Fixing clips
VM4
VE4
ABB | 69
1SBC100155C0202 ShortForm.indb 69
08/10/2010 12:33:33
up to 55 A
Application
cULus
CCC
GOST
C-Tick
CE
AF09 ... AF38 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...).
Description
AF09 ... AF38 contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max.
Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC
AF contactors can manage large control voltage variations. One coil (e.g. 100...250 V 50/60 Hz - DC) can be
used for different control voltages used worldwide without any coil change
AF..Z contactors equipped with a Z coil type allow direct control by 24 V DC 500 mA PLC-output and obtain a
reduced holding coil consumption. AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706
compliance)
AF contactors have built-in surge protection and do not require additional surge suppressors.
Ordering Details
AF09-40-00
IEC
UL/CSA
AC-1
Rated
current
40 C
A
Control voltage
Auxiliary Type
contacts
fitted
Order code
Weight
Pack(ing)
1 piece
kg
AF26-40-00
25
25
30
30
45
45
55
55
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF09Z-40-00-21
AF09-40-00-12
AF09-40-00-13
AF09-40-00-14
AF16Z-40-00-21
AF16-40-00-12
AF16-40-00-13
AF16-40-00-14
AF26Z-40-00-21
AF26-40-00-12
AF26-40-00-13
AF26-40-00-14
AF38Z-40-00-21
AF38-40-00-12
AF38-40-00-13
AF38-40-00-14
0.310
0.270
0.270
0.310
0.310
0.270
0.270
0.310
0.400
0.360
0.360
0.400
0.400
0.360
0.360
0.400
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF09Z-22-00-21
AF09-22-00-12
AF09-22-00-13
AF09-22-00-14
AF16Z-22-00-21
AF16-22-00-12
AF16-22-00-13
AF16-22-00-14
AF26Z-22-00-21
AF26-22-00-12
AF26-22-00-13
AF26-22-00-14
AF38Z-22-00-21
AF38-22-00-12
AF38-22-00-13
AF38-22-00-14
0.310
0.270
0.270
0.310
0.310
0.270
0.270
0.310
0.400
0.360
0.360
0.400
0.400
0.360
0.360
0.400
25
30
30
45
45
55
55
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
10 0.39"
35 1.38"
5.5 0.22"
4.2 0.17"
5.5 0.22"
10 0.39"
5 0.20"
70 | ABB
1SBC101061S0202.indd 70
15/04/2011 13:16:42
2x
M4 8-32 UNC
70 2.76"
70 2.76"
5.5 0.22"
95 3.74"
5 0.20"
5 0.20"
6 0.24"
4.2 0.17"
80
60 3.15"
2.36"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
101 3.98"
2x
M4 8-32 UNC
60 2.36"
1.77"
35451.38"
71 2.80"
35 mm EN/IEC 60715
77 3.03"
45 1.77"
5 0.20"
AF09, AF16
up to 55 A
AF09
Standards
Main poles
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14
690 V
IEC
AF16
AF26
AF38
25 ... 400 Hz
40 C
25 A
30 A
45 A
55 A
60 C
25 A
30 A
40 A
45 A
70 C
22 A
26 A
32 A
37 A
4 mm
6 mm
10 mm
16 mm
25 A
30 A
45 A
55 A
AWG 10
AWG 10
AWG 8
AWG 6
close to contactor
Storage
Magnet system
UL/CSA
600 V AC
DC supply
AC control voltage
24 ... 500 V AC
50/60 Hz
Coil consumption
(AF) 50 VA - (AF..Z) 16 VA
DC control voltage
20 ... 500 V DC
PLC-output control
(AF..Z) 500 mA 24 V DC
Coil consumption
Electromagnetic compatibility
Connecting capacity
Main pole
terminals
Rigid
1 or 2 x
1 ... 6 mm
1.5 ... 16 mm
1 or 2 x
0.75 ... 6 mm
1.5 ... 16 mm
1 or 2 x
AWG 16 ... 10
AWG 16 ... 6
Tightening torque
1.5 Nm / 13 lb.in
2.5 Nm / 22 lb.in
Stripping length
10 mm
12 mm
Coil terminals
Rigid
1 or 2 x
1 ... 2.5 mm
1 or 2 x
1 or 2 x
AWG 18 ... 14
Degree of protection
Tightening torque
1.2 Nm / 11 lb.in
Stripping length
10 mm
IP20
Remark for 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles
1
R3
R5
R4
R6
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit comprising
2 separate loads with a single supply (see diagrams below). When the contactor operates there is no mechanical overlapping
between the N.O. poles and the N.C. poles: BREAK before MAKE.
These contactors are not suitable for a reversing starter or for controlling a single load from 2 separate supplies.
Block diagrams
Single supply and 2 separate loads
Supply
Back-up
supply
A1
R3
A2
R4
R5
A1
R3
R6
A2
R4
R5
R6
Load
Load
Load
Load
ABB | 71
1SBC100155C0202 ShortForm.indb 71
08/10/2010 12:33:41
Main
poles
Built-in
auxiliary
contacts
Front-mounted accessories
Side-mounted accessories
(between 2 contactors)
1-pole CA4
Left side
1-pole CC4
2-pole CAT4-11
4-pole CA4
Right side
2-pole CAL4-11
VEM4
Max. add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 30, 5
4 0
AF09, AF16
0 0
4 max.
or 1
or 1
+ 1
2 max.
or 1
+ 1
+ 1
3 max.
+ 1
+ 1
or 1
Max. add-on N.C. auxiliary contacts: 3 N.C. max. on positions 1, 2, 3, 4 and 2 N.C. max. on positions 1 30, 5
4 max.
or 1
or 1
+ 1
2 max.
or 1
+ 1
+ 1
+ 1
+ 1
or 1
or 1
or 1
+ 1
+ 1
+ 1
AF26, AF38
4 0
0 0
3 max.
AF09, AF16
2 2
0 0
4 max.
AF26, AF38
2 2
0 0
2 max.
or 1
Mounting positions
Pos. 2
+30
-30
Pos. 4
Pos. 3
Pos. 1
Pos. 1 30
Pos. 5
AF contactor
Fixing clips
AF contactor
A2
2-pole CAT4-11
VM4
A2
4-pole CA4
2-pole CAL4-11
1-pole
CA4, CC4
2-pole CAL4-11
1-pole
CA4, CC4
VE4
72 | ABB
1SBC100155C0202 ShortForm.indb 72
08/10/2010 12:33:44
Ordering Details
For contactors
Auxiliary contacts
Type
Order code
Pack(ing) Weight
pieces
kg (1 pce)
CAL4-11
1
1
0
0
2
3
4
0
0
0
1
1
2
1
0
4
CA4-10
CA4-10-T
CA4-01
CA4-01-T
CA4-22E
CA4-31E
CA4-40E
CA4-04E
1
10
1
10
1
1
1
1
0.014
0.014
0.014
0.014
0.055
0.055
0.055
0.055
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
CA4-22E
- - -
1 0
0 1
CC4-10
CC4-01
1
1
0.014
0.014
1
10
0.040
0.040
1 1
1 1
- - -
CAL4-11
CAL4-11-T
1 1
- -
CAT4-11E
0.040
VM4
10
0.005
0.035
Interlocks
Mechanical interlock unit
AF09 ... AF38..-40-00
VEM4
Note: VM4 includes 2 fixing clips (BB4) to maintain together both contactors.
01 NC
01NC
KM2
VEM4
A2
AF09, AF16..-40-00
AF26, AF38..-40-00
1 1
- -
VEM4
Note: VEM4 includes a VM4 mechanical interlock unit with 2 fixing clips (BB4), a VE4 electrical interlock block.
VE4 block must be used with A2-A2 connection to respect the electrical connection diagram.
Fixing clips
AF09 ... AF38..-40-00
BB4
50
0.002
LDC4
10
0.010
BX4
BX4-CA
10
50
0.006
0.001
LDC4
Protective covers
All 1-stack contactors
For 4-pole CA4 and
2-pole CAT4 auxiliary contact blocks
BX4
BX4-CA
ABB | 73
1SBC100155C0202 ShortForm.indb 73
08/10/2010 12:33:47
10 0.39"
10 0.39"
5 0.20"
70 2.76"
2x
M4 8-32 UNC
5 0.20"
5.5 0.22"
35 1.38"
2x
M4 8-32 UNC 4.2 0.17"
70 2.76"
5.5 0.22"
4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
35 1.38"
5.5 0.22"
60 2.36"
71 2.80"
5.5 0.22"
5 0.20"
77 3.03"
45 1.77" 71 2.80"
45 1.77"
5 0.20"
AF09, AF16
AF09, AF16
110.5 4.35"
71 2.80"
45 1.77"
77 3.03"
10 0.39"
12 0.47"
71 2.80"
45 1.77"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
AF09, AF16
+ CA4, CC4 1-pole auxiliary contact block
AF09, AF16
+ CAL4-11 2-pole auxiliary contact block
102.5 4.04"
110.5 4.35"
71 2.80"
10 0.39"
45 1.77"
5.5 0.22"
AF09, AF16
+ CA4 4-pole auxiliary contact block
70 2.76"
60 2.36"
5.5 0.22"
AF09..-40-00, AF16..-40-00
+ VEM4 mechanical and electrical interlock set
2x
2x
M4 8-32 UNC
M4 8-32 UNC
70 2.76"
80 3.15"
5 0.20"
10 0.39"
60 2.36"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
5.5 0.22"
71 2.80" 10 0.39"
5.5 0.22"
5 0.20"
71 2.80"
43 1.69"
90 3.54"
5.5 0.22"
91.5 3.60"
5.5 0.22"
AF09, AF16
+ CAT4 2-pole auxiliary contact and coil terminal block
43 1.69"
90 3.54"
10 0.39"
5.5 0.22"
35 mm EN/IEC 60715
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
71 2.80"
45 1.77"
5 0.20"
AF09..-40-00, AF16..-40-00
+ VEM4 mechanical and electrical interlock set
74 | ABB
1SBC100155C0202 ShortForm.indb 74
08/10/2010 12:33:50
10 0.39"
5 0.20"
10 0.39"
70 2.76"
2x
M4 8-32 UNC
5 0.20"
5.5 0.22"
35 1.38"
2x
M4 8-32 UNC 4.2 0.17"
70 2.76"
5.5 0.22"
4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
80 3.15"
35 mm EN/IEC 60715
6 0.24"
6 0.24"
80 3.15"
35 1.38"
5.5 0.22"
60 2.36"
71 2.80"
5.5 0.22"
5 0.20"
101 3.98"
45 1.77" 95 3.74"
45 1.77"
5 0.20"
AF26, AF38
AF26, AF38
101 3.98"
134.5 5.30"
95 3.74"
45 1.77"
10 0.39"
12 0.47"
95 3.74"
45 1.77"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
AF26, AF38
+ CA4, CC4 1-pole auxiliary contact block
AF26, AF38
+ CAL4-11 2-pole auxiliary contact block
134.5 5.30"
126.5 4.98"
10 0.39"
80 3.15"
43 1.69"
AF26, AF38
+ CA4 4-pole auxiliary contact block
126.5 4.98"
102.5 4.04"
AF26..-40-00, AF38..-40-00
+ VEM4 mechanical and electrical interlock set
2x
2x
M4 8-32 UNC
M4 8-32 UNC
70 2.76"
5.5 0.22"
80 3.15"
5 0.20"
80 3.15"
60 2.36"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
5.5 0.22"
10100.39"
0.39"
5.5 0.22"
70 2.76"
95 3.74" 71 2.80"
60 2.36"
90 3.54"
5.5 0.22"
91.5 3.60"
5.5 0.22"
AF26, AF38
+ CAT4 2-pole auxiliary contact and coil terminal block
43 1.69"
43 1.69"
90 3.54"
10 0.39"
5.5 0.22"
5 0.20"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
95 3.74"
45 1.77"
43 1.69"
95 3.74"
35 mm EN/IEC 60715
45 1.77"
5 0.20"
AF26..-40-00, AF38..-40-00
+ VEM4 mechanical and electrical interlock set
ABB | 75
1SBC100155C0202 ShortForm.indb 75
08/10/2010 12:33:53
No Filter
76 | ABB
1SBC100155C0202 ShortForm.indb 76
08/10/2010 12:33:58
Contactor
Relays
AC / DC control voltage
NF22E
NF31E
NF40E
2 N.O. + 2 N.C.
3 N.O. + 1 N.C.
4 N.O.
4A
3A
2A
6 A / 144 W
0.15 A / 60 W
A600, Q600
240 V
AC-15
400 V
IEC
690 V
24 V
DC-13
400 V
UL/CSA
Pilot Duty
Main Accessories
1-pole CA4-10 or CA4-01, CC4-10 or CC4-01
Front mounting
Auxiliary
contact
blocks
4-pole CA4
2-pole CAL4
Side mounting
CA4
4-pole auxiliary contact block
BX4-CA
Protective cover
CAL4
2-pole auxiliary
contact block
Top or bottom mounted
coil terminal block
CA4, CC4
1-pole auxiliary contact block
BX4
Protective cover
ABB | 77
1SBC100155C0202 ShortForm.indb 77
08/10/2010 12:34:03
NF Contactor Relays
AC / DC Operated - with Screw Terminals
Application
cULus
CCC
GOST
C-Tick
CE
NF contactor relays are used for switching auxiliary and control circuits.
Description
NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max.
Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC
NF contactor relays can manage large control voltage variations. One coil (e.g. 100...250 V 50/60 Hz - DC) can
be used for different control voltages used worldwide without any coil change
NFZ contactor relays equipped with a Z coil type allow direct control by 24 V DC 500 mA PLC-output and obtain
a reduced holding coil consumption.
NFZ contactor relays withstand short voltage dips and voltage sags (SEMI F47-0706 compliance)
NF contactor relays have built-in surge protection and do not require additional surge suppressors
The contactor relays have mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and
include the "Mechanically Linked" symbol on their side.
NF22E
Ordering Details
Number of contacts
Control voltage
1st stack
Weight
Pack(ing)
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
1 piece
kg
0.310
0.270
0.270
0.310
0.310
0.270
0.270
0.310
0.310
0.270
0.270
0.310
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
Type
V DC
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
Order code
NFZ22E-21
NF22E-12
NF22E-13
NF22E-14
NFZ31E-21
NF31E-12
NF31E-13
NF31E-14
NFZ40E-21
NF40E-12
NF40E-13
NF40E-14
77 3.03"
35 1.38"
4.2 0.17"
5.5 0.22"
10 0.39"
2x
M4 8-32 UNC
70 2.76"
60 2.36"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
5 0.20"
71 2.80"
45 1.77"
5 0.20"
78 | ABB
1SBC101062S0202.indd 78
15/04/2011 13:00:47
NF Contactor Relays
AC / DC Operated - with Screw Terminals
Standards
Main poles
IEC
690 V
25 ... 400 Hz
16 A
50/60 Hz
6A
220-240 V
50/60 Hz
4A
400-440 V
50/60 Hz
3A
500 V
50/60 Hz
2A
690 V
50/60 Hz
2A
UL/CSA
24 V DC
6 A / 144 W
48 V DC
2.8 A / 134 W
72 V DC
1 A / 72 W
110 V DC
0.55 A / 60 W
125 V DC
0.55 A / 69 W
220 V DC
0.27 A / 60 W
250 V DC
0.27 A / 68 W
400 V DC
0.15 A / 60 W
500 V DC
0.13 A / 65 W
600 V DC
0.1 A / 60 W
Pilot Duty
A600, Q600
10 A
Storage
Magnet system
DC supply
Coil consumption
(NF) 50 VA - (NFZ) 16 VA
AC
control voltage
50/60 Hz
DC
control voltage
20 ... 500 V DC
PLC-output control
(NFZ) 500 mA 24 V DC
Coil consumption
Electromagnetic compatibility
Connecting capacity
Main pole
terminals
Rigid
1 or 2 x
1 ... 2.5 mm
1 or 2 x
1 or 2 x
AWG 18 ... 14
1.2 Nm / 11 lb.in
Stripping length
Coil
terminals
1 or 2 x
1 ... 2.5 mm
1 or 2 x
1 or 2 x
AWG 18 ... 14
Degree of protection
10 mm
Rigid
Tightening torque
1.2 Nm / 11 lb.in
Stripping length
10 mm
IP 20
ABB | 79
1SBC100155C0202 ShortForm.indb 79
08/10/2010 12:34:07
NF Contactor Relays
Main Accessories
Main
poles
Front-mounted accessories
Side-mounted accessories
1-pole CA4
Left side
1-pole CC4
4-pole CA4
Right side
2-pole CAL4-11
Max. add-on N.C. auxiliary contacts: 3 N.C. max. on positions 1, 2, 3, 4 and 2 N.C. max. on positions 1 30, 5
NF..
2 2
4 max.
or 1
+ 1
NF..
3 1
2 max.
+ 1
+ 1
Max. add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 30, 5
4 0
NF..
4 max.
or 1
+ 1
2 max.
+ 1
+ 1
Mounting positions
Pos. 2
+30
-30
Pos. 4
Pos. 3
Pos. 1
Pos. 1 30
Pos. 5
NF contactor relay
2-pole CAL4-11
4-pole CA4
80 | ABB
1SBC100155C0202 ShortForm.indb 80
08/10/2010 12:34:09
NF Contactor Relays
Main Accessories
Ordering Details
For contactor relays
Auxiliary contacts
Type
Order code
Pack(ing)
pieces
Weight
kg (1 pce)
CA4-22N
NF..40E
1
1
0
0
4
3
2
1
0
0
0
1
1
0
1
2
3
4
CA4-10
CA4-10-T
CA4-01
CA4-01-T
CA4-40N
CA4-31N
CA4-22N
CA4-13N
CA4-04N
1
10
1
10
1
1
1
1
1
0.014
0.014
0.014
0.014
0.055
0.055
0.055
0.055
0.055
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
4-pole NF
- - -
1 0
0 1
1
1
0.014
0.014
CAL4-11
CAL4-11-T
1
10
0.040
0.040
LDC4
10
0.010
BX4
BX4-CA
10
50
0.006
0.001
CC4-10
CC4-01
1 1
1 1
- - -
CAL4-11
Protective covers
LDC4
BX4
BX4-CA
ABB | 81
1SBC100155C0202 ShortForm.indb 81
08/10/2010 12:34:11
NF Contactor Relays
AC / DC Operated - with Screw Terminals
10 0.39"
10 0.39"
5 0.20"
35 1.38"
4.2 0.17"
70 2.76"
2x
M4 8-32 UNC
5 0.20"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
35 1.38"
5.5 0.22"
60 2.36"
71 2.80"
5.5 0.22"
5 0.20"
77 3.03"
45 1.77" 71 2.80"
45 1.77"
5 0.20"
110.5 4.35"
71 2.80"
45 1.77"
10 0.39"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
77 3.03"
12 0.47"
71 2.80"
45 1.77"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
110.5 4.35"
71 2.80"
45 1.77"
10 0.39"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
82 | ABB
1SBC100155C0202 ShortForm.indb 82
08/10/2010 12:34:13
ABB | 83
1SBC100155C0202 ShortForm.indb 83
08/10/2010 12:34:21
1.5 to 18.5 kW
2 to 25 hp
Application
cULus
CCC
GOST
C-Tick
CE
Softstarters from PSR3 up to PSR37 are used for starting and stopping normal standard three phase motors. All
applications benefit from soft starting as it reduces the starting current and limits the mechanical stresses when
starting, giving the equipment a long life.
One of the most common applications is for the operation of pumps, where soft stopping can be used to avoid
water hammering and damage to pipes.
Other common applications are for starting fans, compressors, conveyors, mixers and tooling machines.
Description
PSR softstarters reduce the main voltage during-start using electronically-controlled semiconductors. The PSR
softstarters offer a very compact design thanks to the built-in by-pass contacts in the main circuit. Wide main
voltage range from 208 to 600 V limits the need of variants as well as being very robust and insensitive for voltage
variations. The range from 3 A up to 37 A is designed in three frame sizes. The compact design, clear marking and
limited need for control wiring makes it easy to install.
Types
PSR3 ... PSR16
The PSR range offers types with 24 V DC as well as a 100...240 V AC supply voltage.
The complete range has a run signal contact, while sizes PSR25 ... PSR37 also have a top of ramp signal (T.O.R.)
indicating the end of the start run. Each size of the PSR softstarters can be combined with our manual motor starters
(MMS) using the connection kits. This will result in a very compact starter combination.
Ordering Details
IEC
UL/CSA
Rated
power
400 V
AC-3
kW
1.5
3-phase
motor
rating
480 V
hp
2
5.5
7.5
7.5
10
11
15
15
20
18.5
25
Supply and
control voltage
Auxiliary
contacts
Type
Order code
Weight
Pack(ing)
V AC 50/60 Hz
100...240
100...240
100...240
100...240
100...240
100...240
100...240
100...240
-
V DC
24
24
24
24
24
24
24
24
Run
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
T.O.R.
1
1
1
1
1
1
PSR3-600-70
PSR3-600-81
PSR6-600-70
PSR6-600-81
PSR9-600-70
PSR9-600-81
PSR12-600-70
PSR12-600-81
PSR16-600-70
PSR16-600-81
PSR25-600-70
PSR25-600-81
PSR30-600-70
PSR30-600-81
PSR37-600-70
PSR37-600-81
1 piece
kg
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.650
0.650
0.650
0.650
1.000
1.000
187 mm (7.36)
5 mm (0.20)
172 mm (6.77)
44 mm (1.73)
179 mm (7.05)
3.5 mm (0.14)
PSR37
84 | ABB
1SBC100155C0202 ShortForm.indb 84
08/10/2010 12:34:26
1.5 to 18.5 kW
2 to 25 hp
Softstarter types
PSR3
Standards
Main poles
IEC
UL/CSA
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
PSR37
600 V
AC 50 ... 60 Hz
3.6 A
6.5 A
8.5 A
11.5 A
15.5 A
22 A
29 A
35 A
380-400 V
1.5 kW
3 kW
4 kW
5.5 kW
7.5 kW
11 kW
15 kW
18.5 kW
440-480 V
2 hp
3 hp
5 hp
7.5 hp
10 hp
15 hp
20 hp
25 hp
3.4 A
6.1 A
9A
11 A
15.2 A
24.2 A
28 A
34 A
FLA
4 x Ir for 6 sec.
Starting capacity at Ir
Number of starts per hour
Ambient air
temperature
standard
10 1)
20 1)
Operation
Storage
Supply &
Operating limits
control voltage
AC supply
DC supply
AC supply
50/60 Hz
Power consumption
12 VA
DC supply
24 V DC
Power consumption
5W
Devices complying with IEC 60947-1 / EN 60947-1
Electromagnetic compatibility
Built-in aux.
contacts
IEC
Connecting
capacity
Rigid
Flexible
with ferrule
Capacity acc. to UL/CSA
Rigid
Supply
terminals
Flexible
with ferrule
Capacity acc. to UL/CSA
Degree
of protection
LED
Settings
240 V
250 V
0.5 A
1x
2.5 ... 10 mm
6 ... 35 mm
2x
2.5 ... 10 mm
6 ... 16 mm
1x
2.5 ... 10 mm
6 ... 35 mm
2x
2.5 ... 10 mm
6 ... 16 mm
AWG 18 ... 10
AWG 10 ... 6
AWG 8 ... 4
1x
2x
1x
2x
AWG 18 ... 10
AWG 18 ... 12
1 or 2 x
1 or 2 x
IP 20
for ON/Ready
Green
Green
1-20 sec.
0-20 sec.
40-70%
IP 10
(1) Valid for 50% on the time and 50% off time. 4 x Ie for 6 sec., if other data is required, contact your sales office
(2) Above 40 C up to max. 60 C reduce the rated current with 0.8% per C
ABB | 85
1SBC100155C0202 ShortForm.indb 85
08/10/2010 12:34:27
Ordering Details
Description
Type
Order code
Pack(ing)
pieces
Weight
kg (1 pce)
PS-FBPA
0.060
PSR16-MS116
PSR30-MS132
PSR45-MS450
PSR-FAN3-45
1
1
1
1
0.030
0.030
0.030
0.010
PS-FBPA
PSR16-MS116
PSR45-MS450
PSR-FAN3-45
86 | ABB
1SBC100155C0202 ShortForm.indb 86
08/10/2010 12:34:31
PSR3...PSR16
54 mm (2.13)
187 mm (7.36)
5 mm (0.20)
179 mm (7.05)
44 mm (1.73)
172 mm (6.77)
4 mm (0.16)
3.5 mm (0.14)
PSR25...PSR30
PSR37
ABB | 87
1SBC100155C0202 ShortForm.indb 87
08/10/2010 12:34:33
Index
Order Code Classification
Order code
1SAM 101 923 R0002
1SAM 101 923 R0012
1SAM 101 924 R0003
1SAM 101 924 R0013
1SAM 201 901 R1001
1SAM 201 902 R1001
1SAM 201 902 R1002
1SAM 201 902 R1003
1SAM 201 902 R1004
1SAM 201 903 R1001
1SAM 201 903 R1002
1SAM 201 903 R1003
1SAM 201 904 R1001
1SAM 201 904 R1002
1SAM 201 904 R1003
1SAM 201 904 R1004
1SAM 201 904 R1005
1SAM 201 904 R1006
1SAM 201 904 R1007
1SAM 201 904 R1008
1SAM 201 906 R1102
1SAM 201 906 R1103
1SAM 201 906 R1104
1SAM 201 906 R1105
1SAM 201 906 R1112
1SAM 201 906 R1113
1SAM 201 906 R1114
1SAM 201 906 R1115
1SAM 201 906 R1122
1SAM 201 906 R1123
1SAM 201 906 R1124
1SAM 201 906 R1125
1SAM 201 907 R1101
1SAM 201 907 R1102
1SAM 201 907 R1103
1SAM 201 908 R1001
1SAM 201 910 R1001
1SAM 201 910 R1002
1SAM 201 910 R1003
1SAM 201 910 R1004
1SAM 201 911 R1010
1SAM 201 911 R1011
1SAM 201 912 R1010
1SAM 201 912 R1011
1SAM 201 913 R1103
1SAM 201 916 R1103
1SAM 201 916 R1104
1SAM 201 916 R1105
1SAM 201 916 R1113
1SAM 201 916 R1114
1SAM 201 916 R1115
1SAM 201 916 R1123
1SAM 201 920 R1001
1SAM 201 920 R1002
1SAM 201 920 R1011
1SAM 201 920 R1012
1SAM 250 000 R1001
1SAM 250 000 R1002
1SAM 250 000 R1003
1SAM 250 000 R1004
1SAM 250 000 R1005
1SAM 250 000 R1006
1SAM 250 000 R1007
1SAM 250 000 R1008
1SAM 250 000 R1009
1SAM 250 000 R1010
1SAM 250 000 R1011
1SAM 250 000 R1012
1SAM 301 901 R1001
Type
MSMN
MSMNO
MSOX-32
MSOX-30
HKF1-11
HK1-11
HK1-20
HK1-02
HK1-20L
SK1-11
SK1-20
SK1-02
UA1-24
UA1-48
UA1-60
UA1-120
UA1-230
UA1-400
UA1-415
UA1-208
PS1-2-0-65
PS1-3-0-65
PS1-4-0-65
PS1-5-0-65
PS1-2-1-65
PS1-3-1-65
PS1-4-1-65
PS1-5-1-65
PS1-2-2-65
PS1-3-2-65
PS1-4-2-65
PS1-5-2-65
S1-M1-25
S1-M2-25
S1-M3-25
BS1-3
AA1-24
AA1-110
AA1-230
AA1-400
IB132-G
IB132-Y
DMS132-G
DMS132-Y
S1-M3-35
PS1-3-0-100
PS1-4-0-100
PS1-5-0-100
PS1-3-1-100
PS1-4-1-100
PS1-5-1-100
PS1-3-2-100
MSHD-LB
MSHD-LY
MSHD-LTB
MSHD-LTY
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-16
MS116-12
CK1-11
Page
53
53
53
53
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
51
51
51
51
51
51
51
51
51
51
51
51
51
51
51
51
50
50
50
50
52
52
52
52
51
51
51
51
51
51
51
51
53
53
53
53
46
46
46
46
46
46
46
46
46
46
46
46
50
Order code
1SAM 301 901 R1002
1SAM 301 901 R1003
1SAM 350 000 R1001
1SAM 350 000 R1002
1SAM 350 000 R1003
1SAM 350 000 R1004
1SAM 350 000 R1005
1SAM 350 000 R1006
1SAM 350 000 R1007
1SAM 350 000 R1008
1SAM 350 000 R1009
1SAM 350 000 R1010
1SAM 350 000 R1011
1SAM 350 000 R1012
1SAM 350 000 R1013
1SAM 350 000 R1014
1SAM 350 000 R1015
1SAX 121 001 R1101
1SAX 121 001 R1102
1SAX 121 001 R1103
1SAX 121 001 R1104
1SAX 121 001 R1105
1SAX 221 001 R1101
1SAX 221 001 R1102
1SAZ 721 201 R1005
1SAZ 721 201 R1008
1SAZ 721 201 R1009
1SAZ 721 201 R1013
1SAZ 721 201 R1014
1SAZ 721 201 R1017
1SAZ 721 201 R1021
1SAZ 721 201 R1023
1SAZ 721 201 R1025
1SAZ 721 201 R1028
1SAZ 721 201 R1031
1SAZ 721 201 R1033
1SAZ 721 201 R1035
1SAZ 721 201 R1038
1SAZ 721 201 R1040
1SAZ 721 201 R1043
1SAZ 721 201 R1045
1SAZ 721 201 R1047
1SAZ 721 201 R1049
1SAZ 721 201 R1051
1SAZ 721 201 R1052
1SAZ 721 201 R1053
1SAZ 721 201 R1055
1SBH 136 001 R2122
1SBH 136 001 R2131
1SBH 136 001 R2140
1SBH 137 001 R1222
1SBH 137 001 R1231
1SBH 137 001 R1240
1SBH 137 001 R1322
1SBH 137 001 R1331
1SBH 137 001 R1340
1SBH 137 001 R1422
1SBH 137 001 R1431
1SBH 137 001 R1440
1SBL 136 001 R2101
1SBL 136 001 R2110
1SBL 136 201 R2100
1SBL 136 501 R2100
1SBL 137 001 R1201
1SBL 137 001 R1210
1SBL 137 001 R1301
1SBL 137 001 R1310
1SBL 137 001 R1401
1SBL 137 001 R1410
Type
CK1-20
CK1-02
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.6
MS132-2.5
MS132-4.0
MS132-6.3
MS132-10
MS132-16
MS132-12
MS132-20
MS132-25
MS132-32
EF19-0.32
EF19-1.0
EF19-2.7
EF19-6.3
EF19-18.9
EF45-30
EF45-45
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
NFZ22E-21
NFZ31E-21
NFZ40E-21
NF22E-12
NF31E-12
NF40E-12
NF22E-13
NF31E-13
NF40E-13
NF22E-14
NF31E-14
NF40E-14
AF09Z-30-01-21
AF09Z-30-10-21
AF09Z-40-00-21
AF09Z-22-00-21
AF09-30-01-12
AF09-30-10-12
AF09-30-01-13
AF09-30-10-13
AF09-30-01-14
AF09-30-10-14
Page
50
50
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
66
66
66
66
66
66
66
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
78
78
78
78
78
78
78
78
78
78
78
78
58
58
70
70
58
58
58
58
58
58
Order code
1SBL 137 201 R1200
1SBL 137 201 R1300
1SBL 137 201 R1400
1SBL 137 501 R1200
1SBL 137 501 R1300
1SBL 137 501 R1400
1SBL 156 001 R2101
1SBL 156 001 R2110
1SBL 157 001 R1201
1SBL 157 001 R1210
1SBL 157 001 R1301
1SBL 157 001 R1310
1SBL 157 001 R1401
1SBL 157 001 R1410
1SBL 176 001 R2101
1SBL 176 001 R2110
1SBL 176 201 R2100
1SBL 176 501 R2100
1SBL 177 001 R1201
1SBL 177 001 R1210
1SBL 177 001 R1301
1SBL 177 001 R1310
1SBL 177 001 R1401
1SBL 177 001 R1410
1SBL 177 201 R1200
1SBL 177 201 R1300
1SBL 177 201 R1400
1SBL 177 501 R1200
1SBL 177 501 R1300
1SBL 177 501 R1400
1SBL 236 001 R2100
1SBL 236 201 R2100
1SBL 236 501 R2100
1SBL 237 001 R1200
1SBL 237 001 R1300
1SBL 237 001 R1400
1SBL 237 201 R1200
1SBL 237 201 R1300
1SBL 237 201 R1400
1SBL 237 501 R1200
1SBL 237 501 R1300
1SBL 237 501 R1400
1SBL 276 001 R2100
1SBL 277 001 R1200
1SBL 277 001 R1300
1SBL 277 001 R1400
1SBL 296 001 R2100
1SBL 296 201 R2100
1SBL 296 501 R2100
1SBL 297 001 R1200
1SBL 297 001 R1300
1SBL 297 001 R1400
1SBL 297 201 R1200
1SBL 297 201 R1300
1SBL 297 201 R1400
1SBL 297 501 R1200
1SBL 297 501 R1300
1SBL 297 501 R1400
1SBN 010 110 R1001
1SBN 010 110 R1010
1SBN 010 110 T1001
1SBN 010 110 T1010
1SBN 010 111 R1001
1SBN 010 111 R1010
1SBN 010 120 R1011
1SBN 010 120 T1011
1SBN 010 140 R1004
1SBN 010 140 R1022
1SBN 010 140 R1031
Type
AF09-40-00-12
AF09-40-00-13
AF09-40-00-14
AF09-22-00-12
AF09-22-00-13
AF09-22-00-14
AF12Z-30-01-21
AF12Z-30-10-21
AF12-30-01-12
AF12-30-10-12
AF12-30-01-13
AF12-30-10-13
AF12-30-01-14
AF12-30-10-14
AF16Z-30-01-21
AF16Z-30-10-21
AF16Z-40-00-21
AF16Z-22-00-21
AF16-30-01-12
AF16-30-10-12
AF16-30-01-13
AF16-30-10-13
AF16-30-01-14
AF16-30-10-14
AF16-40-00-12
AF16-40-00-13
AF16-40-00-14
AF16-22-00-12
AF16-22-00-13
AF16-22-00-14
AF26Z-30-00-21
AF26Z-40-00-21
AF26Z-22-00-21
AF26-30-00-12
AF26-30-00-13
AF26-30-00-14
AF26-40-00-12
AF26-40-00-13
AF26-40-00-14
AF26-22-00-12
AF26-22-00-13
AF26-22-00-14
AF30Z-30-00-21
AF30-30-00-12
AF30-30-00-13
AF30-30-00-14
AF38Z-30-00-21
AF38Z-40-00-21
AF38Z-22-00-21
AF38-30-00-12
AF38-30-00-13
AF38-30-00-14
AF38-40-00-12
AF38-40-00-13
AF38-40-00-14
AF38-22-00-12
AF38-22-00-13
AF38-22-00-14
CA4-01
CA4-10
CA4-01-T
CA4-10-T
CC4-01
CC4-10
CAL4-11
CAL4-11-T
CA4-04E
CA4-22E
CA4-31E
Page
70
70
70
70
70
70
58
58
58
58
58
58
58
58
58
58
70
70
58
58
58
58
58
58
70
70
70
70
70
70
58
70
70
58
58
58
70
70
70
70
70
70
58
58
58
58
58
70
70
58
58
58
70
70
70
70
70
70
61
61
61
61
61
61
61
61
61
61
61
Order code
Type
1SBN 010 140 R1040 CA4-40E
1SBN 010 140 R1104 CA4-04M
1SBN 010 140 R1113 CA4-13M
1SBN 010 140 R1122 CA4-22M
1SBN 010 140 R1131 CA4-31M
1SBN 010 140 R1204 CA4-04N
1SBN 010 140 R1213 CA4-13N
1SBN 010 140 R1222 CA4-22N
1SBN 010 140 R1231 CA4-31N
1SBN 010 140 R1240 CA4-40N
1SBN 010 140 R1322 CA4-22U
1SBN 010 140 R1331 CA4-31U
1SBN 010 140 R1340 CA4-40U
1SBN 010 151 R1011 CAT4-11E
1SBN 010 151 R1111 CAT4-11M
1SBN 010 151 R1311 CAT4-11U
1SBN 030 105 T1000 VM4
1SBN 030 111 R1000 VEM4
1SBN 070 156 T1000 LDC4
1SBN 081 306 T1000 BEA16-4
1SBN 081 311 R1000 BER16-4
1SBN 081 313 R2000 BEY16-4
1SBN 082 306 T1000 BEA26-4
1SBN 082 306 T2000 BEA38-4
1SBN 082 311 R1000 BER38-4
1SBN 082 713 R2000 BEY38-4
1SBN 110 108 T1000 BX4
1SBN 110 109 W1000 BX4-CA
1SBN 110 120 W1000 BB4
1SCA 101 647 R1001 OXS6X85
1SCA 101 655 R1001 OXS6X130
1SCA 101 659 R1001 OXS6X180
1SCA 108 043 R1001 OXS6X105
1SFA 896 103 R7000 PSR3-600-70
1SFA 896 103 R8100 PSR3-600-81
1SFA 896 104 R7000 PSR6-600-70
1SFA 896 104 R8100 PSR6-600-81
1SFA 896 105 R7000 PSR9-600-70
1SFA 896 105 R8100 PSR9-600-81
1SFA 896 106 R7000 PSR12-600-70
1SFA 896 106 R8100 PSR12-600-81
1SFA 896 107 R7000 PSR16-600-70
1SFA 896 107 R8100 PSR16-600-81
1SFA 896 108 R7000 PSR25-600-70
1SFA 896 108 R8100 PSR25-600-81
1SFA 896 109 R7000 PSR30-600-70
1SFA 896 109 R8100 PSR30-600-81
1SFA 896 110 R7000 PSR37-600-70
1SFA 896 110 R8100 PSR37-600-81
1SFA 896 211 R1001 PSR16-MS116
1SFA 896 212 R1001 PSR30-MS132
1SFA 896 213 R1001 PSR45-MS450
1SFA 896 311 R1001 PSR-FAN3-45
1SFA 896 312 R1002 PS-FBPA
GJF1 101 903 R0001 SA1
GJF1 101 903 R0002 SA2
GJF1 101 903 R0003 SA3
Page
61
61
61
61
61
81
81
81
81
81
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
53
53
53
53
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
86
86
86
86
86
51
51
51
88 | ABB
Index_1SBC100155C0203.indd 88
15/04/2011 13:19:25
Index
Type Classification
Type
AA1-24
AA1-110
AA1-230
AA1-400
AF09-22-00-12
AF09-22-00-13
AF09-22-00-14
AF09-30-01-12
AF09-30-01-13
AF09-30-01-14
AF09-30-10-12
AF09-30-10-13
AF09-30-10-14
AF09-40-00-12
AF09-40-00-13
AF09-40-00-14
AF09Z-22-00-21
AF09Z-30-01-21
AF09Z-30-10-21
AF09Z-40-00-21
AF12-30-01-12
AF12-30-01-13
AF12-30-01-14
AF12-30-10-12
AF12-30-10-13
AF12-30-10-14
AF12Z-30-01-21
AF12Z-30-10-21
AF16-22-00-12
AF16-22-00-13
AF16-22-00-14
AF16-30-01-12
AF16-30-01-13
AF16-30-01-14
AF16-30-10-12
AF16-30-10-13
AF16-30-10-14
AF16-40-00-12
AF16-40-00-13
AF16-40-00-14
AF16Z-22-00-21
AF16Z-30-01-21
AF16Z-30-10-21
AF16Z-40-00-21
AF26-22-00-12
AF26-22-00-13
AF26-22-00-14
AF26-30-00-12
AF26-30-00-13
AF26-30-00-14
AF26-40-00-12
AF26-40-00-13
AF26-40-00-14
AF26Z-22-00-21
AF26Z-30-00-21
AF26Z-40-00-21
AF30-30-00-12
AF30-30-00-13
AF30-30-00-14
AF30Z-30-00-21
AF38-22-00-12
AF38-22-00-13
AF38-22-00-14
AF38-30-00-12
AF38-30-00-13
AF38-30-00-14
AF38-40-00-12
AF38-40-00-13
AF38-40-00-14
Order code
1SAM 201 910 R1001
1SAM 201 910 R1002
1SAM 201 910 R1003
1SAM 201 910 R1004
1SBL 137 501 R1200
1SBL 137 501 R1300
1SBL 137 501 R1400
1SBL 137 001 R1201
1SBL 137 001 R1301
1SBL 137 001 R1401
1SBL 137 001 R1210
1SBL 137 001 R1310
1SBL 137 001 R1410
1SBL 137 201 R1200
1SBL 137 201 R1300
1SBL 137 201 R1400
1SBL 136 501 R2100
1SBL 136 001 R2101
1SBL 136 001 R2110
1SBL 136 201 R2100
1SBL 157 001 R1201
1SBL 157 001 R1301
1SBL 157 001 R1401
1SBL 157 001 R1210
1SBL 157 001 R1310
1SBL 157 001 R1410
1SBL 156 001 R2101
1SBL 156 001 R2110
1SBL 177 501 R1200
1SBL 177 501 R1300
1SBL 177 501 R1400
1SBL 177 001 R1201
1SBL 177 001 R1301
1SBL 177 001 R1401
1SBL 177 001 R1210
1SBL 177 001 R1310
1SBL 177 001 R1410
1SBL 177 201 R1200
1SBL 177 201 R1300
1SBL 177 201 R1400
1SBL 176 501 R2100
1SBL 176 001 R2101
1SBL 176 001 R2110
1SBL 176 201 R2100
1SBL 237 501 R1200
1SBL 237 501 R1300
1SBL 237 501 R1400
1SBL 237 001 R1200
1SBL 237 001 R1300
1SBL 237 001 R1400
1SBL 237 201 R1200
1SBL 237 201 R1300
1SBL 237 201 R1400
1SBL 236 501 R2100
1SBL 236 001 R2100
1SBL 236 201 R2100
1SBL 277 001 R1200
1SBL 277 001 R1300
1SBL 277 001 R1400
1SBL 276 001 R2100
1SBL 297 501 R1200
1SBL 297 501 R1300
1SBL 297 501 R1400
1SBL 297 001 R1200
1SBL 297 001 R1300
1SBL 297 001 R1400
1SBL 297 201 R1200
1SBL 297 201 R1300
1SBL 297 201 R1400
Page
50
50
50
50
70
70
70
58
58
58
58
58
58
70
70
70
70
58
58
70
58
58
58
58
58
58
58
58
70
70
70
58
58
58
58
58
58
70
70
70
70
58
58
70
70
70
70
58
58
58
70
70
70
70
58
70
58
58
58
58
70
70
70
58
58
58
70
70
70
Type
AF38Z-22-00-21
AF38Z-30-00-21
AF38Z-40-00-21
BB4
BEA16-4
BEA26-4
BEA38-4
BER16-4
BER38-4
BEY16-4
BEY38-4
BS1-3
BX4
BX4-CA
CA4-01
CA4-01-T
CA4-04E
CA4-04M
CA4-04N
CA4-10
CA4-10-T
CA4-13M
CA4-13N
CA4-22E
CA4-22M
CA4-22N
CA4-22U
CA4-31E
CA4-31M
CA4-31N
CA4-31U
CA4-40E
CA4-40N
CA4-40U
CAL4-11
CAL4-11-T
CAT4-11E
CAT4-11M
CAT4-11U
CC4-01
CC4-10
CK1-02
CK1-11
CK1-20
DMS132-G
DMS132-Y
EF19-0.32
EF19-1.0
EF19-2.7
EF19-6.3
EF19-18.9
EF45-30
EF45-45
HK1-02
HK1-11
HK1-20
HK1-20L
HKF1-11
IB132-G
IB132-Y
LDC4
MS116-0.4
MS116-0.16
MS116-0.25
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
Order code
1SBL 296 501 R2100
1SBL 296 001 R2100
1SBL 296 201 R2100
1SBN 110 120 W1000
1SBN 081 306 T1000
1SBN 082 306 T1000
1SBN 082 306 T2000
1SBN 081 311 R1000
1SBN 082 311 R1000
1SBN 081 313 R2000
1SBN 082 713 R2000
1SAM 201 908 R1001
1SBN 110 108 T1000
1SBN 110 109 W1000
1SBN 010 110 R1001
1SBN 010 110 T1001
1SBN 010 140 R1004
1SBN 010 140 R1104
1SBN 010 140 R1204
1SBN 010 110 R1010
1SBN 010 110 T1010
1SBN 010 140 R1113
1SBN 010 140 R1213
1SBN 010 140 R1022
1SBN 010 140 R1122
1SBN 010 140 R1222
1SBN 010 140 R1322
1SBN 010 140 R1031
1SBN 010 140 R1131
1SBN 010 140 R1231
1SBN 010 140 R1331
1SBN 010 140 R1040
1SBN 010 140 R1240
1SBN 010 140 R1340
1SBN 010 120 R1011
1SBN 010 120 T1011
1SBN 010 151 R1011
1SBN 010 151 R1111
1SBN 010 151 R1311
1SBN 010 111 R1001
1SBN 010 111 R1010
1SAM 301 901 R1003
1SAM 301 901 R1001
1SAM 301 901 R1002
1SAM 201 912 R1010
1SAM 201 912 R1011
1SAX 121 001 R1101
1SAX 121 001 R1102
1SAX 121 001 R1103
1SAX 121 001 R1104
1SAX 121 001 R1105
1SAX 221 001 R1101
1SAX 221 001 R1102
1SAM 201 902 R1003
1SAM 201 902 R1001
1SAM 201 902 R1002
1SAM 201 902 R1004
1SAM 201 901 R1001
1SAM 201 911 R1010
1SAM 201 911 R1011
1SBN 070 156 T1000
1SAM 250 000 R1003
1SAM 250 000 R1001
1SAM 250 000 R1002
1SAM 250 000 R1004
1SAM 250 000 R1005
1SAM 250 000 R1006
1SAM 250 000 R1007
1SAM 250 000 R1008
Page
70
58
70
61
61
61
61
61
61
61
61
51
61
61
61
61
61
61
81
61
61
61
81
61
61
81
61
61
61
81
61
61
81
61
61
61
61
61
61
61
61
50
50
50
52
52
66
66
66
66
66
66
66
50
50
50
50
50
52
52
61
46
46
46
46
46
46
46
46
Type
MS116-6.3
MS116-10
MS116-12
MS116-16
MS132-0.4
MS132-0.16
MS132-0.25
MS132-0.63
MS132-1.0
MS132-1.6
MS132-2.5
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-20
MS132-25
MS132-32
MSHD-LB
MSHD-LTB
MSHD-LTY
MSHD-LY
MSMN
MSMNO
MSOX-30
MSOX-32
NF22E-12
NF22E-13
NF22E-14
NF31E-12
NF31E-13
NF31E-14
NF40E-12
NF40E-13
NF40E-14
NFZ22E-21
NFZ31E-21
NFZ40E-21
OXS6X85
OXS6X105
OXS6X130
OXS6X180
PS1-2-0-65
PS1-2-1-65
PS1-2-2-65
PS1-3-0-65
PS1-3-0-100
PS1-3-1-65
PS1-3-1-100
PS1-3-2-65
PS1-3-2-100
PS1-4-0-65
PS1-4-0-100
PS1-4-1-65
PS1-4-1-100
PS1-4-2-65
PS1-5-0-65
PS1-5-0-100
PS1-5-1-65
PS1-5-1-100
PS1-5-2-65
PSR3-600-70
PSR3-600-81
PSR6-600-70
PSR6-600-81
PSR9-600-70
PSR9-600-81
PSR12-600-70
Order code
1SAM 250 000 R1009
1SAM 250 000 R1010
1SAM 250 000 R1012
1SAM 250 000 R1011
1SAM 350 000 R1003
1SAM 350 000 R1001
1SAM 350 000 R1002
1SAM 350 000 R1004
1SAM 350 000 R1005
1SAM 350 000 R1006
1SAM 350 000 R1007
1SAM 350 000 R1008
1SAM 350 000 R1009
1SAM 350 000 R1010
1SAM 350 000 R1012
1SAM 350 000 R1011
1SAM 350 000 R1013
1SAM 350 000 R1014
1SAM 350 000 R1015
1SAM 201 920 R1001
1SAM 201 920 R1011
1SAM 201 920 R1012
1SAM 201 920 R1002
1SAM 101 923 R0002
1SAM 101 923 R0012
1SAM 101 924 R0013
1SAM 101 924 R0003
1SBH 137 001 R1222
1SBH 137 001 R1322
1SBH 137 001 R1422
1SBH 137 001 R1231
1SBH 137 001 R1331
1SBH 137 001 R1431
1SBH 137 001 R1240
1SBH 137 001 R1340
1SBH 137 001 R1440
1SBH 136 001 R2122
1SBH 136 001 R2131
1SBH 136 001 R2140
1SCA 101 647 R1001
1SCA 108 043 R1001
1SCA 101 655 R1001
1SCA 101 659 R1001
1SAM 201 906 R1102
1SAM 201 906 R1112
1SAM 201 906 R1122
1SAM 201 906 R1103
1SAM 201 916 R1103
1SAM 201 906 R1113
1SAM 201 916 R1113
1SAM 201 906 R1123
1SAM 201 916 R1123
1SAM 201 906 R1104
1SAM 201 916 R1104
1SAM 201 906 R1114
1SAM 201 916 R1114
1SAM 201 906 R1124
1SAM 201 906 R1105
1SAM 201 916 R1105
1SAM 201 906 R1115
1SAM 201 916 R1115
1SAM 201 906 R1125
1SFA 896 103 R7000
1SFA 896 103 R8100
1SFA 896 104 R7000
1SFA 896 104 R8100
1SFA 896 105 R7000
1SFA 896 105 R8100
1SFA 896 106 R7000
Page
46
46
46
46
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
53
53
53
53
53
53
53
53
78
78
78
78
78
78
78
78
78
78
78
78
53
53
53
53
51
51
51
51
51
51
51
51
51
51
51
51
51
51
51
51
51
51
51
84
84
84
84
84
84
84
Type
PSR12-600-81
PSR16-600-70
PSR16-600-81
PSR16-MS116
PSR25-600-70
PSR25-600-81
PSR30-600-70
PSR30-600-81
PSR30-MS132
PSR37-600-70
PSR37-600-81
PSR45-MS450
PSR-FAN3-45
PS-FBPA
S1-M1-25
S1-M2-25
S1-M3-25
S1-M3-35
SA1
SA2
SA3
SK1-02
SK1-11
SK1-20
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
UA1-24
UA1-48
UA1-60
UA1-120
UA1-208
UA1-230
UA1-400
UA1-415
VEM4
VM4
Order code
1SFA 896 106 R8100
1SFA 896 107 R7000
1SFA 896 107 R8100
1SFA 896 211 R1001
1SFA 896 108 R7000
1SFA 896 108 R8100
1SFA 896 109 R7000
1SFA 896 109 R8100
1SFA 896 212 R1001
1SFA 896 110 R7000
1SFA 896 110 R8100
1SFA 896 213 R1001
1SFA 896 311 R1001
1SFA 896 312 R1002
1SAM 201 907 R1101
1SAM 201 907 R1102
1SAM 201 907 R1103
1SAM 201 913 R1103
GJF1 101 903 R0001
GJF1 101 903 R0002
GJF1 101 903 R0003
1SAM 201 903 R1003
1SAM 201 903 R1001
1SAM 201 903 R1002
1SAZ 721 201 R1005
1SAZ 721 201 R1008
1SAZ 721 201 R1009
1SAZ 721 201 R1013
1SAZ 721 201 R1014
1SAZ 721 201 R1017
1SAZ 721 201 R1021
1SAZ 721 201 R1023
1SAZ 721 201 R1025
1SAZ 721 201 R1028
1SAZ 721 201 R1031
1SAZ 721 201 R1033
1SAZ 721 201 R1035
1SAZ 721 201 R1038
1SAZ 721 201 R1040
1SAZ 721 201 R1043
1SAZ 721 201 R1045
1SAZ 721 201 R1047
1SAZ 721 201 R1049
1SAZ 721 201 R1051
1SAZ 721 201 R1052
1SAZ 721 201 R1053
1SAZ 721 201 R1055
1SAM 201 904 R1001
1SAM 201 904 R1002
1SAM 201 904 R1003
1SAM 201 904 R1004
1SAM 201 904 R1008
1SAM 201 904 R1005
1SAM 201 904 R1006
1SAM 201 904 R1007
1SBN 030 111 R1000
1SBN 030 105 T1000
Page
84
84
84
86
84
84
84
84
86
84
84
86
86
86
51
51
51
51
51
51
51
50
50
50
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
50
50
50
50
50
50
50
50
61
61
ABB | 89
Index_1SBC100155C0203.indd 89
15/04/2011 13:19:26
ABB France
Low Voltage Products Division
10, rue Ampre Z.I. - B.P. 114
F-69685 Chassieu cedex / France
Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or
possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents in whole or in parts is
forbidden without prior written consent of ABB.
Copyright 2011 ABB
All rights reserved
Contact us
www.abb.com/lowvoltage
4cover_1SBC100155C0203.indd 2
15/04/2011 13:21:08