Beruflich Dokumente
Kultur Dokumente
Internal Use
Handover Practice
There are three cells in one BSC: CELL A/CELL B/CELL C The setting of parameter as follow: Cell name Band Cell layer 3 3 2 Inter-layer HO Threshold 25 25 20 Inter-layer Hysteresis 3 3 3 Edge HO DL Rx-LEV Threshold 25 25 20 PBGT HO Threshold 68 68 68 Inter-cell Hysteresis 5 5 4
And the signal level as follow, please sort the cell and list the possible normal HO Typefor example the 1st line
No. Serving cell Neighbor cell 1 Neighbor cell 2 Rx-LEV (serving) Rx-LEV (neighbor1) Rx-LEV (neighbor2) Cell ranking Possible HO Type
1 2 3 4 5
A B A B C
C C C C A
B A B A B
CBA
Edge HOCell C
Explanation to example 1:
2010-11-9
Huawei Confidential
Page 1, Total 3
Practice
Internal Use
Cell B: 25+3=28 -110+28= -82dbm -81>-82 so so14bit=0 Cell C: 20+3=23 -110+23=-87dbm -86>-87 so 14bit=0 13/12bit: they are in one BSC, so 13/12bit=0 10-5bit, supposed: 00 = micro layer = cell layer 1 01 = 1800 layer = cell layer 2 10 = 900 layer = cell layer 3 11 = umbrella layer = cell layer 4 4 bit : Cell A is service cell, so set 0 Cell B -81>-87+5 so set 0
Cell C -86<-87+5 so set 1 3-1bit: Based on signal level, cell B >cell C >cell A, so assumed cell B 00 cell C 01 cell A 10 so result is as follow: Cell name Cell A 16/15bit 14bit 13/12bit 11bit 10-5bit 4bit 3-1bit Order
ignored
ignored
10
10
2010-11-9
Huawei Confidential
Page 2, Total 3
Practice
Internal Use
Cell B Cell C
ignored ignored
0 0
0 0
ignored ignored
10 01
0 1
00 01
2 1
2010-11-9
Huawei Confidential
Page 3, Total 3