Sie sind auf Seite 1von 4

SR. NO. A 1.

0 HI-SIDE HVAC WORKS

DESCRIPTION

UNIT

QTY.

RATE INR

AMOUNT INR

1.1 1.2 1.3 2.0

Supply of Air cooled conventional Ductable split units of Blue star / Carrier / Voltas Make. Supply of ductable split type conditioning units,each comprising of an outdoor and a single/double indoor unit/s.Condensing unit shall be complete with hermatically sealed rotary/ scroll compressor/s, with aluminium fins, thermostatic expansion valve and air cooled condenser with fan. Evaporating unit shall consist of a fan section with dynamically balanced centrifugal fan/s driven by FHP/TEFC squirrel cage induction motor, multirows deep cooling coil of copper tubes and aluminium fins etc. Enclosures shall be fabricated as specified. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. The outdoor unit enclosure shall be factory painted to a smooth finish. Ductable three phase units shall be complete with phase reversal kit and motor protection device. Three phase ductable split units : Nos. 11.0 TR Ceiling suspended Ductable split units with twin circuit Nos. 8.5 TR Ceiling suspended Ductable split units with single circuit Nos. 5.5 TR Ceiling suspended Ductable split units with single circuit Supply of Air cooled Inverter type Hi-wall split units of Daikin / Toshiba / Blue star / Carrier / Voltas / Samsung Make. Supply of wall mounted split type airconditioning units, each comprising of an outdoor and single/double indoor unit. Condensing unit shall be complete with Inverter compressor/s & air cooled condenser with fan. Evaporating unit shall consist of a fan section with dynamically balanced centrifugal fans driven by FHP motor, multirows deep cooling coil of Copper tubes and aluminium fins, thermostatic expansion valves etc. Enclosures shall be fabricated as specified. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit.The enclosure shall be factory painted to a smooth finish. 2.0 TR Hi-wall mounted split units Nos. 1.5 TR Hi-wall mounted split units Nos. SUB TOTAL A Supply, Installation, Testing & commissioning of followings

1 6 1

2.1 2.2

2 2 0

B 1.0

LOW SIDE WORKS Air cooled conventional type ductable split units. Low side works of following machines including lifting, shifting, supply, fabrication, installation of MS base platform for indoor/outdoor unit complete with epoxy painting, vibration isolation pads, support hangars, railing, brackets etc.Canvass connections with zip as approved by consultants.Outdoor unit structure with access ladder to be provided by AC contractor. This also shall include complete testing & commissioning. The quoted price shall be inclusive of full charge of refrigerant gas. 11.0 TR Ceiling suspended Ductable split units with twin circuit 8.5 TR Ceiling suspended Ductable split units with single circuit 5.5 TR Ceiling suspended Ductable split units with single circuit Nos. Nos. Nos. 1 6 1

1.1 1.2 1.3 2.0

2.1 2.2 3.0

Air cooled Inverter type Hi-wall split units. Low side works of following machines including lifting, shifting, supply, fabrication, installation of MS base platform for indoor/outdoor unit complete with epoxy painting, vibration isolation pads, support hangars, railing, brackets etc.This also shall include complete testing & commissioning. The quoted price shall be inclusive of full charge of refrigerant gas. 2.0 TR Hi-wall mounted split units Nos. 1.5 TR Hi-wall mounted split units Nos. Refrigerant Piping & Cabling for Air cooled ducable split units.

2 2

SR. NO.

DESCRIPTION Supply, Installation, Testing and Commissioning of hard/soft copper refregerant piping complete with fittings between indoor units and remote condensers. Refrigerant piping complete for all circuits with suction line insulation of min. 9 mm thick Armaflex make & electrical cabling & conduiting with proper supporting arrangement @ every 4 feet.. 11.0 TR Ceiling suspended Ductable split units with twin circuit Refrigerant piping FRLS Power cabling FRLS Control cabling Isolator switch of IP-55 construction near outdoor/indoor unit 8.5 TR Ceiling suspended Ductable split units with single circuit Refrigerant piping FRLS Power cabling FRLS Control cabling Isolator switch of IP-55 construction near outdoor/indoor unit 5.5 TR Ceiling suspended Ductable split units with single circuit Refrigerant piping FRLS Power cabling FRLS Control cabling Isolator switch of IP-55 construction near outdoor/indoor unit Refrigerant Piping for Air cooled Hi-wall split units. Supply, Installation, Testing & Commissioning of Ref. piping complete for all circuits with suction & liquid line insulation of min. 9 mm thick Armaflex make & electrical cabling & conduiting with proper supporting arrangement @ every 4 feet. 2.0 TR Hi-wall split units. Refrigerant piping FRLS Power cabling FRLS Control cabling Isolator switch of IP-55 construction near outdoor unit 1.5 TR Hi-wall split units. Refrigerant piping FRLS Power cabling FRLS Control cabling Isolator switch of IP-55 construction near outdoor unit Canvass connections with zip ASPEN make Drain Pump kit. for Hi-wall split units. for Ductable split units.

UNIT

QTY.

RATE INR

AMOUNT INR

3.1

Rmt. Rmt. Rmt. Nos.

30 40 40 2

3.2

Rmt. Rmt. Rmt. Nos.

120 150 150 6

3.3

Rmt. Rmt. Rmt. Nos.

15 20 20 1

4.0

4.1

Rmt Rmt Rmt Nos.

40 50 50 2

4.2

Rmt Rmt Rmt Nos. No.

40 50 50 2 8

5.0 6.0 6.1 6.2 7.0

Nos. Nos.

4 1

Drain Piping Drain Piping shall be Hard PVC.25mm dia for single unit, 40mm dia for two units and 50mm dia for 3 units. Drain Piping shall be insulated with 12mm Armaflex. Rmt. SHEET METAL WORKS Rectangular ducting Local factory fabricated complete with splitter dampers, turning vanes, access doors, supports, air tight joints applied with sealant etc. as per drawings. 24 G 22 G 20 G 18 G INSULATED FLEXIBLE DUCT 175 mm dia 150 mm dia 100 mm dia

200

8.0

M M M M

400 100 50 U.R.

9.0

Rmt. Rmt. Rmt.

U.R. U.R. U.R.

10.0 AIR DISTRIBUTION OUTLET

SR. NO.

DESCRIPTION

UNIT

QTY.

RATE INR

AMOUNT INR

10.1 Supply & Installation of Supply air / Return air Aluminium extruded Powder Coated 2/3 slot Grille of sizes 100 / 150 mm with end flanges. 10.2 Supply & Installation of Supply air / Return air Aluminium extruded Powder Coated linear bar Grille 0 /15/45deg deflection of size 100/150 mm with end flanges. 100mm wide 150mm wide 10.3 Supply & Installation of Supply / Return air 600x600 size Aluminium extruded Powder Coated core type modular ceiling diffusers with/without damper of following neck size. 150x150 with damper 225x225 with damper 300x300 with damper 375x375 with damper 450x450 with damper 150x150 without damper 225x225 without damper 300x300 without damper 375x375 without damper 450x450 without damper 10.4 Supply & Installation of Supply / Return air 300x300 size Aluminium extruded Powder Coated core type Gypsum ceiling diffusers with/without damper of following neck size. 150x150 with damper 225x225 with damper 150x150 without damper 225x225 without damper

U.R.

M M

40

Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos.

U.R. U.R. U.R. U.R. U.R. U.R. U.R. U.R. U.R. U.R.

Nos. Nos. Nos. Nos.

U.R. U.R. U.R. U.R.

10.5 Supply & Installation of GI butterfly dampers to match collar size for each supply air Nos. outlet. The same shall have locking arrangement. 10.6 Opposed blade dampers black powder coated vertical blade type for supply air collar. The damper should be gear operated type. 10.7 Volume Control Dampers made out of 100 x 40 x 1.55 mm thick galvanized steel frame and with opposed blades of 1.55 mm galvanized sheet steel. 10.8 200mmx150mm Door Transfer grilles for toilets & pantry doors.

U.R.

10

M Nos.

5 8

10.9 Supply& Installation of Fresh air intake connections with rain protection louvers, bird Nos. screen ( Al. 26 G min. ) & volume control damper gear operated type. 10.10 Supply & Installation of Exhaust air outlet connections with cowl and bird screen ( Al. Nos. 26 G min.). 11.0 INSULATIONS 11.1 DUCT ACOUSTIC INSULATION Acoustic Insulation with 25mm thick 32 kg/cm3 density covered with 2 layer of RP i tissue and 26 G of Al.perforated sheet as shown in the drawing ( UP Twiga Make) ii Acoustic Insulation with self adhesive 20mm thick "Armasound " Armacell make nitrile rubber insulation. Supply & Installation of Accoustic insulation of 25 mm thick self adhesive nitrile rubber ( arma sound ) over False ceiling / trap door of Ceiling suspended AHU.

U.R.

125

U.R.

iii

Sqm

100

11.2 DUCT THERMAL INSULATION Thermal insulation with 25 mm thick Fiberglass of UP Twiga make with factory i backed Aluminium foil of density 24 Kg /Cum with cris-cross wire & strapping at every 4 feet distance. ii Thermal Insulation with self adhesive 19 mm thick "Armaflex " Armacell make nitrile rubber insulation.

650

U.R.

SR. NO.

DESCRIPTION

UNIT

QTY.

RATE INR

AMOUNT INR

11.3 ROOF INSULATION i Supply & installation of 50 mm TF quality Thermocole and finished with chicken wire netting of 22G GI twined wire fixed to the purlins. Make:- Beardsell / Equivalent. 12.0 FRESH AIR & EXHAUST AIR FANS 12.1 Axial fans & propeller fans Supply, installation, testing and commissioning of the following Axial fans & propeller type exhaust/ fresh air fans. Power will be provided 2 M away from fan & necessary wiring with plug will be mountred by AC contractor. 1000 CFM @ 10 mm S.P. Axial type Exhaust air fan of Kruger / Systemair make 150 CFM @ 10 mm S.P. propeller Exhaust air fans. 300 CFM @ 10 mm S.P. propeller Exhaust air fans. 100 CFM @ 10 mm S.P. propeller Exhaust air fans. 13.0 SUB TOTAL B C ANNUAL MAINTENANCE CONTRACT 1st Year after handover to be included as Guarantee 2nd Year 3rd Year 4th Year SUB TOTAL ' C ' GRAND TOTAL A+B+C Note : The above price shall include all taxes & duties

1100

Nos. Nos. Nos. Nos. Lot.

3 4 2 2 1 0

Lot. Lot. Lot. 1