Network Doctor Reports List

Report No.
Network Entities
90 NETWORK CONFIGRATION SUMMARY This report shows statistics about the capacity of the network. - NSS, DX220, SMSC, VMS network entity sums for each MR and total sum. - BSS network entity sums for each MR and sum over the network. - BTS sums for each MR and sum over the network per band. This report lists all Maintenance Regions in the network and the number of objects in them. This report displays all BSCs in the network and the number of BTSs, LAPDs, PCMs and Gb-interface 64k channels under them. Only the BTSs and TRXs having an actual parameter set (i.e. those that exist in the network) are counted. This report lists all MSCs in the network. This report lists all HLRs in the network. This report lists all base station sites (BCF objects) of the selected maintenance region in alphabetical order. The host BSC is shown as well as the number of BTSs (sectors) in each BS Note that the number of BTSs counts only those BTSs which exist in the network, not those which exist in the database only.

Report Configuration Management

Description

91 MAINTENANCE REGIONS 92 BSCs

93 MSCs 94 HLRs 95 BASE STATION SITES OF A MAINTENANCE REGION 96 LOCATION AREAS 97 PLMNs 99

89

103

54

The identifiers of all Location Area Codes (LAC) used in the network are presented with the number of cells (BTS) under each LA. This report lists all PLMNs created in NetAct database and the number of objects in them. BCF SOFTWARE AND HARDWARE TYPE Report consists of 2 parts. STATISTICS Part 1 reports all the BCFs in the selected area. Part 2 gives summary by BCF types. BSC OPTION STATISTICS All the BSCs in the selected area are reported. Note: Only the options used in the BSC are listed. Information is updated to NetAct database only at upload. Later (at the earliest in T11) the data will be updated automatically. ROUTING AREAS The identifiers of all Routing Area Codes (RAC) used in the network are presented with the number of used (usd) and unused (nus) cells (BTS) under each RA. Used cell means a cell that is unlocked and its parent BCF is also unlocked. Unused cell means a cell that is locked and/or its parent BCF is locked. SEGMENT CONFIGURATION This report lists all base station sites of the selected Maintenance Region in alphabetical order. The number of cells (BTS) in each base station is counted for all existing BTSs in the network This report displays all base station sites sorted out by BSC name, BCF ID and BTS ID. Only those BTSs and TRXs are reported which have the <ACTUAL> value, i.e. those created in the network. This report lists the CIs, LACs and names of all cells in the selected BTS area sorted out according to CI and LAC. This script displays all BCFs or BTSs which have the given string in the name. Note that the search string is case sensitive! The search is done based on the BCF name. This script displays all cells (segments) which have the given Cell Identify and Location Area Code.

Find Cells
41 ALL BASE STATION SITES PER MAINTENANCE REGION 42 ALL RADIO NETWORK SORTED OUT BY BSC, BCF AND BTS 43 ALL CELLS WITH LAC AND CI 44 FIND BS SITES (BCF) HAVING THE GIVEN CHARACTER STRING IN THE NAME 45 FIND CELLS HAVING THE GIVEN CI AND LAC 46 FIND CELLS HAVING AN ADJACENT CELL WITH THE GIVEN CI AND LAC 47 FIND CELLS HAVING THE GIVEN FREQUENCY 50 FIND LOCKED BCFs, BTSs, TRXs AND CHANNELS

51 BTS HAVING GPRS ENABLED TRXS

This report displays all cells which have the given frequency. This report lists - all locked BCFs - all locked BTSs - all locked TRXs - all locked channels This report provides a list of GPRS BTSs and their parameter settings.

Checks
65 ADJACENCIES TO NON-EXISTING OR FOREIGN CELLS 60 ADJACENCY DISCREPANCIES 61 NON-SYMMETRICAL ADJACENCIES Normally every adjacency should be towards an existing cell This report lists the discrepancies of various parameters between the source cell adjacency parameters and target cell parameters. This report shows all missing adjacencies assuming that all adjacencies should be symmetrical (bidirectional). The missing adjacencies are sorted out by BSCs and segment names. The maintenance region is checked for source cells. This report displays all adjacencies where a cell and its adjacent cell have the same frequency (f) or adjacent (f-1 or f+1) frequency. The maintenance region is checked for source cells. For each pair of frequencies also the administrative state (S) of objects (BCF, TRX) is shown as well as the use of TRX (BCCH or TCH). Decoding of states (S): N= No state U= Unlocked S= Shutting down L= Locked Adjacent cells should never have the same BCCH and BSIC. The same frequencies should not be used in adjacent cells. Also the f-1 or f+1situation should be avoided if possible. Note: If the TRX is a BCCH TRX, the output power is maximal all the time. This report lists all cells having adjacent cells with the same frequency. This is a potential source of interference. Note: Every occurrence is listed twice. Input parameters: BTS area Instructions: The reported pairs of target cells have to be checked with network planners. This report shows pairs of cells that are adjacent cells of the same source cell and have the same NCC, BCC and BCCH frequency. This report contains all CI-LAC pairs that have been defined for at least two master BTSs. A CI-LAC pair must be unique throughout the entire network on segment level, but not on BTS level. This report lists all adjacencies - that are in the same BS site but are not synchronous . This is serious and may result in call failures and decrease . voice quality - that are not in the same BS site but are synchronous . This is serious and can result in call failures A synchronous HO means that the MS uses the old value of timing advance. A non-synchronous HO means that the MS finds the new value of timing advance. Normally only adjacent cells in the same site are synchronous for HO. This report shows the usage of the parameters in the network or part of it, including objects that have the value <ACTUAL> in c_bts. Instructions: Use the report 063 to find out the parameter differences on the BTS level. The checking is done over the BTSs in the selected area that use the defined band. The defaults are listed below. All discrepancies are reported. A comparison is made against the defaults stored in NetAct database. If the defaults are not yet generated they are inserted by this script. There is one default set for each of four possible bands: <DEFAULT>GSM900, <DEFAULT>GSM1800, <DEFAULT>GSM1900, <DEFAULT>GSM850. The defaults can be modified by using GUI. Instructions: 1) Run this report against a cell that you would like to use as default. . Then you will see how the defaults differ from the model cell. 2) Correct the defaults by using GUI. 3) Run the report over a larger area of cells. All objects under each BSC are checked if they don't belong to the same MR as the BSC or to any MR. This report shows the usage of the BSC-parameters in the network or part of it. The count of BSCs on the area selected. Instructions: Use the report 078 to find out the parameter differences.

62 FREQUENCY CHECK OF ADJACENT CELLS

69 ADJACENT CELL DOUBLE FREQUENCIES

76 ADJACENT CELLS OF A CELL HAVING THE SAME NCC,BCC AND FREQUENCY 66 NON-UNIQUE CI AND LAC 67 HANDOVER SYNCHRONISATION

68 BTS PARAMETER SURVEY

63 BTS AUDIT

64 MAINTENANCE REGION AUDIT 77 BSC PARAMETER SURVEY

78 BTS state conflict between BSC and MSC This report checks if the administrative state of BTS in MSC is different than the state in BSC, i.e. - Case 1: cell unlocked in MSC but either BCF or BTS is locked in BSC - Case 2: cell locked in MSC but BCF and BTS are unlocked in BSC (causes LUs) 53 AMR PARAMETERS 55 EGPRS PARAMETERS

Adjacencies
70 BTSs WITH MAXIMUM NUMBER OF ADJACENCIES 71 CELLS WITH MINIMUM NUMBER OF ADJACENCIES 72 DEFINED, UNDEFINED AND USED ADJACENCIES OF A CELL 73 UNDEFINED ADJACENT CELLS 74 ADJACENCIES OF CELLS This report shows the number of adjacencies for each cell in the network where this number exceeds the threshold. All cells should have at least one neighbour, and cells with few neighbours are unusual. This report helps detect cells with too few defined neighbours. This report shows the defined adjacencies (from NetAct database) and undefined adjacencies as seen and reported by a BSC. This report gives all undefined adjacent cells UAC (cells measured by MS but not defined as neighbour of the serving cell) for all BTSs in the selected area. This information can be used to check the network plan for adjacencies. For each adjacency the following parameters are given as the output. LAC Location area code of the target cell. CI Cell identification of the target cell. BCC Base station colour code of the target cell. FREQ BCCH frequency of the target cell.

75 BTSs WITH MAX NBR OF ADJACENCIES TO DIFFERENT LOCATION AREAS

Named Parameter Set Audit


80 NUMBER OF NAMED PARAMETER SETS This report shows the number of named sets for BTS objects. PER OBJECT TYPE Actual, Lastomc, Default, Backup and Clipboard sets are not counted. If the number is high (thousands in the whole network), it should be studied if the sets are really needed. 81 NAMED SETS USED This report shows all named sets used in a Maintenance Region or network. Actual, Lastomc, Default and Clipboard sets are not presented because they are usual. 82 ALLOCATION OF A NAMED SET This report shows the allocation of the given named set in the market.

Frequincies
110 OCCURRENCE OF FREQUENCIES 111 FREQUENCY PLAN This report shows the number of occurrences of each frequency. Only frequencies of used TRXs (TRX and its parent objects are unlocked) are counted. This report shows frequency plan related information about a BTS. In this report the cells are listed according to the dominant distance range, in other words the range having the biggest share of the meas. samples. The Distance Range is based on Timing Advance. In this report the cells are listed with the distance range. This report analyses the TCH observation recods and counts the distribution of the Timing Advance values per each TRX of the selected BTS. Occur Nbr of records havign the TA value. Share Percentual share of the records with the TA value out of all records.

Cell Coverage
231 CELLS BY DOMINANT DISTANCE RANGE 232 DISTANCE RANGE DISTRIBUTION PER CELL 234 TIMING ADVANCE DISTRIBUTION PER TRX

Fault Management
20 ALARM STATISTICS There are five defined alarm classes: Critical (***), Major (**), Minor (*), Warning (W) This script analyses the alarms stored for the time period defined, and counts the number of instances of each alarm class. The script also reports on alarm counts for different network entities This report shows the number of alarms per object type. It has two parts. The first part gives the alarm statistics by alarm severity class, the second part shows the common statistics. The objects BCF, BTS, and TRX counted in this report are real working ones, i.e. all of them are unlocked and their parents are unlocked. This report checks NetAct database for different types of alarms and lists the alarming object, alarm ID, alarm name and alarm count for each alarm type within the given period. The check is performed for the whole network. This report checks NetAct database for different types of alarms and lists the alarm urgency class, amount of alarm, alarming object, alarm ID and alarm name for each alarm type within the given period and selected BSC(s). The list is sorted by urgency class and the amount of alarms. In order to find out the sources and occurrences of a particular alarm you may run report 030. All alarms with a given id that are started within the given period are arranged with alarm start time shown in descending order. The 'BCCH missing' alarm stands for cell outage. These alarms are listed in chronological order per BSC. In S7, the alarm ID changes from 2567 to 7767. This report searches for both IDs. The sum time of selected alarm is calculated for each BTS (cell) in minutes over the given period. The BCCH missing alarms (2567 until S7, 7767 since S7) receivd from the area during the given period are presented for all BTSs over a period of 10 days. The number in the table means the number of occurrences of 'BCCH missing' alarms (i.e. the start of BTS outage) during the day. Note that the BCCH missing alarm means that the BTS has been down. Alarms (ID given by user) received from the network are presented for all MSCs over 10 days.

36 NUMBER OF ALARMS PER OBJECT

34 ALARM TYPES AND COUNTS

35 ALARM TYPES AND COUNTS FOR BSC

23 ALARM-SPECIFIC STATISTICS FOR EACH BTS 24 ACTIVE BCCH MISSING (2567,7767) ALARMS 25 ALARM SUM TIME BY CELLS 27 BTS OUTAGE BREAKDOWN OVER 10 DAYS

30 BSC ALARM BREAKDOWN

Performance Management BSS


BSS PM Administration
127 LAST BSS MEASUREMENT RECORD TIMES 121 FIRST AND LAST BSS MEASUREMENT RECORD TIMES FOR EACH BSC This report shows the date and time of last records available in NetAct for each measurement type. This report shows by BSCs the date and time of the first and last records available in NetAct database for the selected measurement type. First record (start time) Start time of the first measurement record. Last record (start time) Start time of the last measurement record. Period duration max. Maximum of period durations. Period duration min. Minimum of period durations. This report shows the number of records, minimum reporting period and maximum reporting period for every hour having measurement results for the selected measurement type. The hour and minutes shown is the beginning time of the measurement period. The number of records, minimum reporting period and maximum reporting period are reported for every hour having measurement results for the selected measurement type. This report shows all BTSs/TRXs per obsevation type having records in NetAct database. This report lists all cells for which there are undefined adjacent cell measurement results in NetAct database. This information is needed before using the report 072. The report gives the following figures sorted out by the selected column for all cells meeting the thresholds. For rejections both the % value and the absolute sum are counted. The % values are counted in proportion to counter c3004 (Channel required msg rcvd). This report shows each measurement period having SDCCH congestion over the given threshold. This report shows each measurement period having TCH congestion over the given threshold. This reports lists all cells having 1 % or more TCH assigns rejected because of lacking resources. The output is sorted out by the number of hours and BSC name. Only cells with average number of non-available TSLs over the given threshold are reported. This report shows for each BSC in the network: Unava. due to user (%) /uav_4 Share of unavailability caused by user. Unava. due to int. (%) /uav_5 -"- caused by internal reasons Unava. due to ext. (%) /uav_6 -"- caused by external reasons Unava. TRX time due to user (min) /uav_7 TRX unavailability time caused by user. Unava. TRX time due to int. (min) /uav_8 -"- caused by internal reasons Unava. TRX time due to ext. (min) /uav_9 -"- caused by external reasons Measurement used: p_nbsc_trx_avail This report shows cells having SMS establishment failures over a given period. This report can be run on BTS or segment level. Nbr of SMS est.attempts /sms_4 Number of SMS establishment attempts. SMS flr % on TCH /sms_2 SMS establishment failure ratio on TCH. SMS flr % on SDCCH /sms_3 SMS establishment failure ratio on SDCCH. Tot SMS flr % /sms_1 Total SMS establishment failure ratio. Measurement used: p_nbsc_res_access

122 RECORDS FOR A MEASUREMENT TYPE, OVER BTS AREA 126 RECORDS FOR A MEASUREMENT TYPE, OVER BSC 124 TCH AND SDCCH OBSERVATIONS RECORDS 125 CELLS HAVING UNDEFINED ADJACENT MEASUREMENT RESULTS

SDCCH and TCH Access, availability


134 CELLS HAVING RACH REJECTIONS

130 CELLS HAVING SDCCH CONGESTION 135 CELLS HAVING TCH CONGESTION 138 CELLS HAVING HIGH TCH RAW BLOCKING 139 CELLS HAVING UNAVAILABLE RADIO TIME SLOTS (TSL) 131 UNAVAILABILITY CLASSIFICATION PER BSC

132 CELLS HAVING SMS ESTABLISHMENT FAILURES

Handover
150 CELLS HAVING HIGH HO FAILURE RATIO This report shows HO failure rates for all cells sorted out by failure rate. Note that HO failure does not yet mean a dropped call because in most cases the call is successfully returned to the old channel. The target for an acceptable HO failure rate has to be set by the operator but generally it should stay under 10% for normal sites. CELLS HAVING HIGH HO For each cell: ATTEMPTS/CALL RATIO HO/calls ratio (%) /trf_13e Doesn't include intra-cell HOs. Number of handovers /c1008 TCH seizures for HO Number of calls /trf_39a TCH seizures for new call . (normal, DR and FCS) Measurement used: p_nbsc_ho, p_nbsc_traffic TRHO handovers (AMH) This report shows the counters related to Advanced Multilayer Handling for those cells that have either TCH requests for a BSC controlled TRHO or HO attempts to other cell due to BSC controlled TRHO. TRHO att (src) c4035 HO attempts to other cell due to BSC controlled TRHO . (triggered in source cell where as other counters . are triggered in target cell) TRHO req (tgt) c1167 TCH requests for a BSC controlled TRHO TRHO seiz(tgt) c1168 Successful TCH seizures for BSC controlled TRHO TRHO rej (tgt) c1169 Rejected TCH requests for a BSC controlled TRHO due . to exceeded load in the target cell Measurement used: Traffic, Handover DADLB handovers This report shows the counters related to DADLB (Direct Access to Desired Layer or band) per selected object level area/BSC/BTS) and per selected time aggregation (total/daily/hourly). In a BTS level report M indicates the Master BTS of the segment. ADJACENCIES HAVING HIGH HO Part 1:FAILURE RATIO This report gives a list of adjacencies for the HO type you have selected, either all or only those between different bands, and both the HO failure ratio and the number of HO attempts that equal or exceed the given thresholds. Part 2 :This report gives the summaries of HOs between frequency bands. Depending on your selection, either all HOs or only those between different bands are shown. Part 3 :This report gives the summaries of HOs between BCF types. The BCF type of the master BTS of the segment is used in the report. WCDMA ADJACENCIES HAVING HIGH Performance indicators used in this report: HO FAILURE RATIO c93002 Number of inter-system HO attempts to the WCDMA RAN cell. blck_27 HO blocking percentage to target WCDMA cell. hfr_69 HO failure percentage of non-blocked HO attempts to the WCDMA cell. hfr_70 HO failure percentage of non-blocked HO attempts from the WCDMA cell. blck_28 HO blocking percentage from target WCDMA cell. c93005 Number of inter-system HO attempts from the WCDMA RAN cell. Measurement used: p_nbsc_utran_ho_adj_cell COMMON BCCH, MULTI-BCF HO Note that only the counters from HO measurement are used when you run the report on BTS or segment level because CC PM measurement is on BSC-level. Measurements used: p_nbsc_ho, p_nbsc_cc_pm (only in BSC-level report) HO ATTEMPT CAUSE DISTRIBUTION BY The cells are listed in the order of selected cause. Value '0' in all columns means that there has been no handovers. CELLS INTRA BSS HO OBSERVATION This report counts the HO attempts, failure % and drop % for various HO cases. STATISTICS HO Drop % 100*(sum of HOs with ho_fail_cause = 6) / nbr of HOs HO Fail % 100*(sum of HOs with ho_fail_cause != 0) / nbr of HOs Observation used: p_nbsc_int_ho_obs

157

155

156

153

159

151

154 158

Drop Call
160 TCH DROP CALL STATISTICS BY DAYS ACROSS AREA 162 TCH DROP CALL STATISTICS PER DAY IN EACH BSC 163 CELLS HAVING HIGH TCH DROP CALL RATIO 164 TRANSCODER FAILURES 166 SDCCH DROP RATIO PER CELL 167 CELLS HAVING HIGH DROP CALL COUNT IN HANDOVERS Measurement used: p_nbsc_traffic, p_nbsc_ho, p_nbsc_service Measurement used: p_nbsc_traffic, p_nbsc_ho Measurements used: Traffic, Handover, Service, Res. Avail. Note: This report covers the calls after a successful TCH seizure attempt. The sums of failures are counted over the given time period. Measurement used: p_nbsc_traffic Measurement used: p_nbsc_traffic, p_nbsc_res_access Note: This report covers calls in the SDCCH phase. This report lists all cells having drop calls in handovers more than the given threshold. The distribution of drop calls is given for each cell. Reported for each BSC or MR: Traffic /trf_1a TCH CS traffic in Erlang Congestion /cngt_1 Congestion time in seconds Avail TCHs /ava_5 Number of available TCHs Measurement used: p_nbsc_res_avail Measurement used: p_nbsc_traffic, p_nbsc_res_avail, p_nbsc_res_access Note: The results are shown only for those hours when there are results from Traffic and Resource Availability measurements. Measurement used: p_nbsc_res_avail, p_nbsc_traffic

Traffic and Load


180 TCH TRAFFIC (ERLANG) PER HOUR FOR EACH BSC OR MR

181 DAILY TCH TRAFFIC PROFILE FOR A BTS 182 BUSY HOUR TRAFFIC FOR ALL CELLS 183 LOW TRAFFIC CELL CHECK-UP

184

185

186 187

189

202

222 236 224

The cells are analysed to find out the number of hours when the following condition is fulfilled: . (SDCCH_SEIZ_ATT=0) OR . (SDCCH_ASSIGN=0) OR . (TCH_HO_SEIZ=0 AND TCH_NORM_SEIZ>0) OR . (TCH_NORM_SEIZ=0 AND TCH_HO_SEIZ>0) The condition means that the hour is counted if there are no SDCCH seizure attempts or assignments or there are only HO bids or only call bids. Measurement used: p_nbsc_traffic BSC UNIT LOAD PER HOUR FOR EACH For every processor unit of all BSCs: BSC Avg load /trf_20 Average load of unit Min peak load /c6004 Minimum peak load of unit Max peak load /c6004 Maximum peak load of unit Peak hour /c6007 Time when maximum peak load of unit occurs For processor units the average load of 70% is critical and the average of 60% should not be exceeded. For MB the average load should not exceed 50%. Measurement used: p_nbsc_load CELLS HAVING MAXIMUM TCH TRAFFIC Measurements used: p_nbsc_traffic . p_nbsc_res_avail . p_nbsc_ho . p_nbsc_dual_band CELLS HAVING MAXIMUM PAGING The cells are reported in the order of number of paging messages sent. TRAFFIC Measurement used: p_nbsc_res_access CELL LOCATION UPDATES The BTSs are reported in the order of average LU counts (Avg LU). A high LU amount can cause SDCCH blocking. One possible reason is a MS moving across LA border in idle mode. A high number of HOs from other LAs may also mean a high number of idle MSs moving from another area. Measurement used: p_nbsc_traffic, p_nbsc_res_access, p_nbsc_res_avail, p_nbsc_ho_adj CELLS SORTED OUT BY SDCCH OR Measurement used: p_nbsc_res_avail TCH HOLDING TIME For each cell reported: Average SDCCH holding time /trf_4 Average FTCH holding time /trf_5 CELLS HAVING MOST DELETE This report shows the BTSs with reference to the greatest number of delete indication messages and P-Immediate INDICATIONS and P-IMM.ASS.NACK Assignment NACK in descending order. Measurement used: p_nbsc_res_access, p_nbsc_packet_control_unit CALL DISTRIBUTION PER LA Measurement used: p_nbsc_res_access. CELLS HAVING MAX. HTCH TRAFFIC This report lists either all cells having HTCH available or HTCH traffic. Measurement used: p_nbsc_res_avail CELL TRAFFIC 7-DAY/24-HOUR This report gives the 7 days / 24 hours break-down of TCH traffic (trf_12b) Erlangs. BREAKDOWNS Measurement used: p_nbsc_res_avail. PART 1 :The first report shows the cells with interference, averaged across segment, and the hour for the period given. PART 2:The second report shows the breakdown of interference, over 24 hours of each of the last ten days. The values per hour mean the percentage of time slots out of band 1. The higher the value, the worse the interference. A blank value stands for missing PM data; it does not mean that there isn't any interference. Used counter formula: itf_1 Measurement used: p_nbsc_res_avail UL AND DL QUALITY, UL PART 1: TRX HIT LIST INTERFERENCE PER TRX, PART 2, INTERFERENCE PROFILE 24-HOUR/10-DAY BREAKDOWNS PART 3: FREQUENCY PROFILE Measurement used: p_nbsc_rx_qual, p_nbsc_power (mandatory) UL AND DL QUALITY PER TRX Measurement used: p_nbsc_rx_statistics Distribution of call samples by codecs and This report shows the call sample distribution for AMR and nonAMR modes. You can choose Time (total, day, hour) and quality classes (BER) object aggregation level (TRX, BTS, BSC, whole area, MR). On BTS summary level the list is sorted by the number of call samples, otherwise by object names and time. Measurements associated: p_nbsc_rx_qual Distribution of call samples by codecs and This report shows call sample distribution over all used codec types and FER classes. quality classes (FER) dynamic time and Time (total,day,hour) and object aggregation level ( TRX, BTS,BSC,whole area,MR, TRX) can be chosen. object aggregation Measurements associated: p_nbsc_fer AMR call time and quality, dynamic time This report shows the KPIs for checking and object aggregation - interference - call time: non-AMR, FR AMR, FR AMR (see report 244 for more details) - BER based quality KPIs (see report 244 for more details) - FER (UL) and FEP (DL) based quality KPIs (see report 245 for more details) Measurements associated: p_nbsc_power, p_nbsc_rx_qual, p_nbs_fer (TRX level measurements) TRXS BY DL AND UL LEVEL BALANCE Measurement used: p_nbsc_power CELLS BY DOMINANT LINK BALANCE In this report the cells are listed according to the dominant path balance range, i.e the range having the biggest share of RANGE the path balance measurement samples. MS pwr level path bal (dB) Difference between UL and DL signal levels. Share in range (%) Share of path balance measurements. Measurement used: p_nbsc_link_balance CELLS HAVING BAD LINK BALANCE (DL, For each cell the share (%) of samples in the given range is counted. Cell having less than the given % of samples in the UL) range are reported. Measurement used: p_nbsc_link_balance LINK BALANCE PER TRX This report counts the power loss balance between UL and DL for each TRX of each cell of the selected area. In this report it is assumed that the max BS power is 44.7 dBm. Measurement used: p_nbsc_power LINK BALANCE OF AN AREA For the given period the matrix contains the share (%) of each case and the total number of samples over the period. Measurement used: p_nbsc_link_balance

Interference, Quality and Link Balance


190 CELLS HAVING UL INTERFERENCE, 24-HOUR/10-DAY BREAKDOWNS

196

197 244

245

246

195 198

191

208

199

IUO
401 IUO CELLS BY AVERAGE TRAFFIC ABSORPTION TO SUPER TRXs 403 KPI Statistics for IUO-Cells (based on average Traffic not Busy Hour) 402 IUO CELLS BY BUSY HOUR TRAFFIC ABSORPTION TO SUPER TRXs 400 IUO COUNTERS OF A CELL 405 FREQUENCY CHECK OF ADJACENT CELLS (IUO SUPER TRX EXCLUDED) Measurement used: p_nbsc_underlay

Measurement used: p_nbsc_underlay, p_nbsc_traffic, p_nbsc_ho The absolute busy hour by traffic is defined for each cell and for this hour the absorption of the traffic to super TRXs is calculated. This report shows counter information about IUO for one cell. Measurement used: p_nbsc_traffic, p_nbsc_underlay, p_nbsc_rx_qual, p_nbsc_ho, p_nbsc_res_avail This report displays all adjacencies where a cell and its adjacent cell have the same frequency or adjacent frequency. The Selected Area is checked for source cells. For each pair of frequencies also the administrative state (S) of objects (BCF,BTS,TRX) is shown as well as the use of TRX (BCCH or TCH). Measurement used: p_nbsc_underlay C/I Ratio measurement is an optional feature of BSC (BSS6081). It collects data on every call ongoing in the test cell and its interfering cells. Measurement can be activated only for one BTS in one BSC Interfereing cells can compose either all adjacent cells or 6 given cells. When MS is in test cell the DL C/I ratio is the ratio of DL signal level of test cell to that of each interfering cell. When MS is in interfering cell theDL C/I ratio is the ratio of DL signal level of the interfereing cell to that of the test cell. Measurement used: p_nbsc_ci_ratio

404 IUO MEASUREMENT DATA PER BTS 407 C/I STATISTICS

Call Success
250 CELLS BY CALL SUCCESS RATIO 251 CALL SUCCESS PROFILES OF A CELL Measurement used: p_nbsc_traffic, p_nbsc_ho, p_nbsc_res_access, p_nbsc_res_avail Measurement used: p_nbsc_traffic, p_nbsc_ho, p_nbsc_res_access, p_nbsc_service

BSS transmission availability and quality


518 TRANSMISSION STATISTICS 1. DMR - Measurement used: p_nbsc_dmr 2. DN2 - Measurement used: p_nbsc_dn2 3. TRU - Measurement used: p_nbsc_tru_bie 4. BSC-ET 5. TCSM-ET Measurement used: p_nbsc_dmr Measurement used: p_nbsc_dn2 Measurement used: p_nbsc_tru_bie Note: If abnormality indication is selected, then only those ETs are shown where ava_8<100 or err_sec>0 or err_sec_severe>0 BSC-ET. Availability and quality Measurement used: p_nbsc_et_bsc TCSM-ET. Availability and quality TCSM-ET. Missing signals and frame alignments. TCSM-ET. Alarm indications. TCSM-ET. Frame errors and slips. Measurement used: p_nbsc_et_tcsm This report contains statistics about Q1-generation transmission elements related to the feature BSS8120. Measurement used: p_nbsc_tre This report contains statistics about Q1-generation transmission elements related to the feature BSS8120. Measurement used: p_nbsc_tre_sel This report allows to generate a GPRS KPI table with various object and time aggregation levels. The table is sorted out by RLC data volume trf_74 (UL and DL) if the time aggregation is the whole period. Otherwise it is BSC, BTS id and time. In a BTS level report M indicates the Master BTS of the segment. This report is normally used so that you first run the report with average time aggregation and when you find an interesting BTS, zoom into that by using the daily or hourly time aggregation. Avoid using hourly time aggregation with large BTS areas and long periods of time (long output, higher load on the system) Measurements used: p_nbsc_traffic, . p_nbsc_packet_control_unit, . p_nbsc_res_avail, . p_nbsc_res_access This report allows to generate an EGPRS KPI table with various object and time aggregation levels. The table is sorted out by total RLC data volume trf_74+trf_167 (UL and DL) if the time aggregation is the whole period. Otherwise it is BSC, BTS id and time. This report is normally used so that you first run the report with average time aggregation and when you find an interesting BTS, zoom into that by using the daily or hourly time aggregation. Avoid using hourly time aggregation with large BTS areas and long periods of time (long output, higher load on the system) Measurements used: p_nbsc_res_avail, . p_nbsc_traffic, . p_nbsc_packet_control_unit, . p_nbsc_coding_scheme This report shows the uplink PS traffic and its components. List is ordered by the traffic but in case daily or hourly time aggregation it is ordered by the object and time. Measurement used: PCU This report shows the downlink PS traffic and its components. List is ordered by the traffic but in case daily or hourly time aggregation it is ordered by the object and time. Measurement used: PCU With BTS level summary the list is ordered by territory upgrade requests otherwise it is ordered by the object and time. Measurement used: Traffic, Resource Availability This report can be run on BTS or Segment level. Measurement used: PCU This report shows the TBF related PIs. Measurement used: p_nbsc_packet_control_unit Measurement used: Frame Relay Note: For UL congestion there is an alarm 3027 Measurement used: Frame Relay Note: For UL congestion there is an alarm 3027. This report shows statistics for PBCCH availability. Measurement used: p_nbsc_pbcch_avail This report can be used to: . - find pools where the pool capacity is not adequate and to reconfigure . cells for using pools where capacity is available. . - check which cells are in the pool. Measurement used: p_nbsc_dynamic_abis Measurements associated: p_nbsc_qos Measurement used: p_nbsc_coding_scheme This report shows detailed and versatile information about a cell in relation to its behaviour. The report allows you to see by one command many aspects about the cell and use this information to correlate the events and make the diagnosis. This report shows detailed and versatile information about a cell in relation to its behaviour. The report allows you to see by one command many aspects about the cell and use this information to correlate the events and make the diagnosis. This report gives the sum (or maximum in the case of a peak value counter) of all GPRS counters. You can use these figures for verifying the KPI formulas or learnig about the basic counter level. This report gives the sum (or max in case of peak value counter) of all counters. These figures can be used for verifying the KPI formulas or learnig about the basic counter level. Only those measurements are covered that provide data on cell level. Measurements used: p_sgsn_mobility_management, p_sgsn_session_management, p_sgsn_sms This report provides a list of GPRS BTSs and their parameter settings. The identifiers of all Routing Area Codes (RAC) used in the network are presented with the number of used (usd) and unused (nus) cells (BTS) under each RA. Used cell means a cell that is unlocked and its parent BCF is also unlocked. Unused cell means a cell that is locked and/or its parent BCF is locked. Measurements used: p_nbsc_packet_control_unit p_nbsc_res_access PART I - BTSs matching condition 1 PART II - BTSs matching condition 2 PART III - Summary of Sleeping GPRS BTSs report

515 DMR PROFILE 516 DN2 PROFILE 517 TRU PROFILE

522 BSC ET PROFILE 523 TCSM ET PROFILE

525 TRE PROFILE 526 TRE-SEL PROFILE

(E)GPRS
229 GPRS KPIs

226 (E)GPRS KPIs

237 UL PS TRAFFIC

238 DL PS TRAFFIC

239 TERRITORY UPGRADE, DOWNGRADE

228 CELLS BY MULTISLOT REQUESTS AND ALLOCATIONS 254 TBF PI 240 FRAME RELAY 243 FRAME RELAY 255 PBCCH AVAILABILITY PI 280 DYNAMIC ABIS

270 Quality of Service PI 275 EGPRS RLC STATISTICS 211 CELL DOCTOR

213 BTS DOCTOR

235 GPRS COUNTERS 700 CELL RELATED SGSN COUNTERS

51 BTS HAVING GPRS ENABLED TRXS 103 ROUTING AREAS

257 SLEEPING GPRS BTSs

AMR
244 Distribution of call samples by codecs and This report shows the call sample distribution for AMR and nonAMR modes. quality classes (BER) Measurements associated: p_nbsc_rx_qual PART 1 Distribution of call samples by codecs and quality classes PART 2 Bitrates (kbps) and occurences for each codec set used in the BTS area during given time period 245 Distribution of call samples by codecs and This report shows call sample distribution over all used codec types and FER classes. quality classes (FER) dynamic time and Measurements associated: p_nbsc_fer object aggregation PART 1 Distribution of call samples by codecs and quality classes (ulq_3,dlq_3) PART 2 Boundaries used in the selected area for defining the classes 246 AMR call time and quality, dynamic time This report shows the KPIs for checking and object aggregation - interference - call time: non-AMR, FR AMR, FR AMR (see report 244 for more details) - BER based quality KPIs (see report 244 for more details) - FER (UL) and FEP (DL) based quality KPIs (see report 245 for more details) Measurements associated: p_nbsc_power, p_nbsc_rx_qual, p_nbs_fer (TRX level measurements) 247 Transcoder failure ratio This report shows TCH seizure and failure statistics for different speech codecs. Measurements associated: p_nbsc_traffic 248 Codec set modification failure ratio This report shows seizure and failure statistics for codec set modifications. Measurements associated: p_nbsc_traffic 249 AMR COUNTERS SUMMARY This report gives the sum of all AMR related counters. These figures can used for verifying the KPI formulas or learnig about the basic counter level. Measurement used: p_nbsc_traffic, p_nbsc_rx_quality 53 AMR PARAMETERS

Position based services (PBS)


260 TCH DROP CALL STATISTICS BY DAYS ACROSS AREA Measurement used: p_nbsc_traffic, p_nbsc_ho, p_nbsc_service Note: This report covers the calls after a successful TCH seizure attempt. This report displays for the selected BSC - The number of calls per a clear code counter - The number of calls per phase and clear code. Measurement used: p_nbsc_cc_pm Measurement used: p_nbsc_ms_speed This report gives the sum (or max in case of peak value counter) of all counters. These figures can used for verifying the KPI formulas or learnig about the basic counter level. Measurement used: p_nbsc_high_speed_data This report shows the KPIs for HSCSD on BTS or BSC or area level. Measurement used: Traffic, HSCSD

Other BSS PM
220 CLEAR CODE STATISTICS

203 LOCATION UPDATE SUCCESS RATIO PER BSC 233 CELLS BY MS SPEED 241 HSCSD COUNTERS

242 HSCSD KPIS

Benchmark and analysis


200 PERFORMANCE STATISTICS (BENCHMARK) You can select this report to show data from the following areas: - object information - basic parameter settings - daily performance statistics - adjancency check Measurement used: p_nbsc_ho, p_nbsc_traffic, p_nbsc_res_access, p_nbsc_res_avail, p_nbsc_rx_qual, p_nbsc_service This report provides versatile information about the selected BTS area. - objects - key parameters - Key Performance Indicators Measurement used: p_nbsc_traffic, p_nbsc_ho, p_nbsc_power, p_nbsc_res_access, p_nbsc_res_avail, p_nbsc_rx_qual, p_nbsc_rx_statistics, p_nbsc_service p_nbsc_fer, p_nbsc_pbcch_avail This report provides 10-day profiles of the indicators listed below. - SDCCH availability - SDCCH usage - TCH availability - TCH usage - TCH traffic - SDCCH access probability - SDCCH success ratio - TCH access probability - TCH success ratio Measurement used: p_nbsc_traffic, p_nbsc_res_avail, p_nbsc_res_access, p_nbsc_ho This report calculates the basic set of BSS KPIs used to evaluate the quality of the network. Measurements used: p_nbsc_traffic, p_nbsc_ho, p_nbsc_res_access, p_nbsc_res_avail, p_nbsc_rx_qual, p_nbsc_service

204 NETWORK BENCHMARK STATISTICS

207 PERFORMANCE PROFILES FOR AREA (24-HOUR/10-DAY BREAKDOWNS)

800 QUALITY SURVEY

205 BTS GSM KPI/PI table, dynamic object and time aggregation

This report offers the most practical PIs and KPIs to analyse BTS performance. Measurements associated: p_nbsc_res_avail, p_nbsc_traffic, p_nbsc_ho, p_nbsc_res_access, p_nbsc_service, p_nbsc_packet_control_unit, p_nbsc_rx_qual, p_nbsc_high_speed_data, p_nbsc_fer 206 TRX level GSM KPI/PI table, dynamic time This report shows the PIs and KPIs that are useful at least on TRX level. and object aggregation Measurements associated: p_nbsc_res_access, p_nbsc_power, p_nbsc_rx_qual (TRX level measurements) 212 BSC DOCTOR BSC Doctor gives versatile information about the selected BSC. 216 BTS ANALYSER This report shows detailed and versatile information about a cell related to its behaviour. This is the prime report to troubleshoot a cell. 221 BASE STATION SITE CHECK This report gives basic information about all cells of a BS site. Measurement used: p_nbsc_traffic, p_nbsc_ho, p_nbsc_service, p_nbsc_res_avail. 211 CELL DOCTOR This report shows detailed and versatile information about a cell in relation to its behaviour. 213 BTS DOCTOR This report shows detailed and versatile information about a cell in relation to its behaviour. 215 AVAILABILITY PER BSC UNIT This report shows for each unit of each BSC the total disconnection time and total number of restarts over the given time period. Measurement used: p_nbsc_avail 217 SDCCH, TCH and BSC OUT HO This report gives statistics of all SDCCH and TCH observations. OBSERVATION STATISTICS The sums of different cause_out's are shown for each phase-out and per observation object. 225 Drop call trace This report gives drop call details for the selected BTS over the give time period contains the following parts: Part 1: Configuration of the BTS Gives necessary generic info Part 2: Dropped calls summary Gives overview. Part 3: Drop call trace Gives details that are helpful in troubleshooting. Data is organised in order of the tracing reference. Each trace is an indvidual drop. Measurement used: p_nbsc_dc_obs (optional feature Drop Call Trace Window in BSC) 223 Handover cause stats, BSC internal Hos This report shows the counts of handovers by causes and failed HO causes for each cell pair having records in Internal Handover Observation table. Observation used: (p_nbsc_int_ho_obs)