S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION

Reference: PE/ICM/APP/0255

Version: 01.04/EN

Date of issue: 16/06/99

This confidential document is the property of NORTEL MATRA CELLULAR and may not be copied or circulated without permission

CONTENTS 1.
1.1. 1.2.

INTRODUCTION ......................................................................................................................4
OBJECT............................................................................................................................................ 4 SCOPE.............................................................................................................................................. 4

2.
2.1. 2.2.

RELATED DOCUMENTS ........................................................................................................4


REFERENCE DOCUMENTS.......................................................................................................... 4 APPLICABLE DOCUMENTS ........................................................................................................ 4

3.
3.1. 3.2.

ABBREVIATIONS AND TERMS............................................................................................5


ABBREVIATIONS .......................................................................................................................... 5 TERMS............................................................................................................................................. 5

4. 5.
5.1. 5.2. 5.3. 5.4.

PREREQUISITES......................................................................................................................6 RESOURCES..............................................................................................................................6
HUMAN RESOURCES ................................................................................................................... 6 HARDWARE TOOLS ..................................................................................................................... 6 SOFTWARE TOOLS....................................................................................................................... 6 INSTALLATION SUPPLIES .......................................................................................................... 6

6.
6.1. 6.2.

SAFETY.......................................................................................................................................7
STAFF SAFETY .............................................................................................................................. 7 EQUIPMENT SAFETY ................................................................................................................... 7

7. 8. 9.

STRATEGY OF INSTALLATION ..........................................................................................8 IMPACTS ON THE NETWORK .............................................................................................8 QUALITY CONTROL ..............................................................................................................8

10. SEQUENCE OF OPERATIONS...............................................................................................8 Z END OF DOCUMENT Y ..........................................................................................................33

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 2

SHEETS SHEET S1 SHEET S2 SHEET S3 SHEET S4 SHEET S5 SHEET S6 SHEET S7 SHEET S8 SHEET S9 SHEET S10 Hardware checks .........................................................................................9 Site status checks ......................................................................................10 Site shutdown............................................................................................11 Cabinet power off......................................................................................13 Equipment removing.................................................................................14 Ambient air thermistor installation ...........................................................15 New equipments installation.....................................................................16 Cabinet power up ......................................................................................18 Site return in service .................................................................................19 Final checks...............................................................................................20 APPENDICES Appendix 1 Kit components .....................................................................................................21 Appendix 2 Font view of the cabinet........................................................................................22 Appendix 3 AC box general view.............................................................................................23 Appendix 4 Battery cabinet.......................................................................................................26 Appendix 5 Thermistor installation ..........................................................................................27 Appendix 6 Control board ........................................................................................................29 Appendix 7 View of the ambient thermistor final installation .................................................30 Appendix 8 Report sheet...........................................................................................................31

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 3

1.
1.1.

INTRODUCTION
OBJECT
This document describes the acoustic noise reduction kit installation on a S8000 outdoor BTS.

1.2.

SCOPE
This operation may be performed only on any S8000 outdoor BTS equipped with the climatic system DACS. The BTS is equipped with BCF or CBCF.

2.
2.1.

RELATED DOCUMENTS
REFERENCE DOCUMENTS
None

2.2.

APPLICABLE DOCUMENTS
All PE/ICM documents listed below are Core I&C Methods product documents. These documents must be available on site at the latest version (refer to the project documentation status list). On a given project some of those documents may be replaced by other project specific ones (refer to the report sheet that indicates for each document which reference is applicable). For the document phased with the system release, refer to the report sheet that indicates for each document which reference is applicable. All applicable documents are referenced in the report sheet. [A1] [A2] [A3] Or Or Or Site preparation and installation document Packing list V8 OMC-R operations called by I&C procedures V9 OMC-R operations called by I&C procedures V10 OMC-R operations called by I&C procedures V11 OMC-R operations called by I&C procedures : : : : : : Project document Project document PE/ICM/APP/0071 PE/ICM/APP/0144 PE/ICM/APP/0188 PE/ICM/APP/0218

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 4

3.
3.1.
BCF BTS CSWM DACS DRX DSC GND GTW LED OMC PA PCMI PCU

ABBREVIATIONS AND TERMS


ABBREVIATIONS
: : : : : : : : : : : : : : : : Base Common Function Base Transceiver Station Control and switching matrix Direct Ambient Climatic System Low RF-power Driver and Receiver Data signaling concentrator GrouND Gateway Light emitting diode Operation & Maintenance center Power Amplifier Pulse code modulation interface Power Control Unit Power supply command synchronization unit Transmitter

PSCMD SYNC TX

3.2.

TERMS
Installer Coordinator Supervisor Person in charge of the installation Person in charge of coordinating the project installation Person in charge to supervising a site installation

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 5

4.

PREREQUISITES
The use of this procedure requires the availability on site of : - The filled-out report sheet (See Appendix at the end of this document) which gives all required input data to apply the procedure. - All the applicable documents listed in paragraph 2.2.

5.
5.1.

RESOURCES
HUMAN RESOURCES
- One OMC Technician on the OMC site. - One Installer on the BTS site ( two installers required for safety reasons if this is a roof-top or a site remotely located).

5.2.

HARDWARE TOOLS
Description Drilling machine Drills for metal Standard centre punch Screwdriver for phillips heads Hand riveters Five-tread stepladders Crimping pliers for insulated terminals Vacuum cleaner small type with batteries extra long blade (N 2, 250 mm) for 3 mm Comments wireless type Size : 3.5 mm - 6.5 mm

5.3.

SOFTWARE TOOLS
None.

5.4.

INSTALLATION SUPPLIES
Acoustic noise reduction kit : NTQA 97 AB. Adhesives rules to catch the cutting of metal.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 6

6.
6.1.

SAFETY
STAFF SAFETY
Any operation on an outside site is forbidden in case of thunder storm, heavy rain or high wind. You must switch off the circuit-breaker at the operator AC interface, and disactivate the batteries before manipulating the power supply wiring of the AC box and of the rectifier shelf. The AC switch-off provokes the batteries discharge (the BTS remains powered with - 48V DC). If the batteries are internal, turn off the battery disconnect switch located above the rectifier shelf of the BTS cabinet to disactivate them. If there is a separate battery cabinet, turn off the DC circuit-breaker located at the bottom-left of the battery cabinet to disactivate them.

6.2.

EQUIPMENT SAFETY
In case of rainy / snowy weather, do not open a cabinet without a tent set up beforehand. A tent specific to the S8000 Outdoor BTS cabinet is available. Never leave wet equipment inside the cabinet (tent, etc...). Initially powered, the S8000 BTS cabinet is operational during 3 hours door open at a temperature of -10C (~ 14F). Once this time is passed the door opening of the powered-up BTS cabinet is only possible with the use of an external heated shelter (use a tent and heaters). Be careful with the cutting of metal. Clean the DACS after the operation of drilling.

WARNING:

When the blowers are switched off, it is mandatory to wait a complete stop before attempting to restart. In practice this means ensuring a period od least 30 second after switch off before switching back on.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 7

7.

STRATEGY OF INSTALLATION
The installation of the noise reduction kit may be performed on a DACS in a warehouse. The working condition is better. In this case only the replacement of the DACS is achieved on site.

8.

IMPACTS ON THE NETWORK


During the installation of the kit on site, the cabinet is not operational. These operations must be performed at the appropriate time, to limit call attempt failures from the network subscribers. Duration of site unavailability is estimated at 1.5 hours in the worst case.

9.

QUALITY CONTROL
- All cases of non-compliance must be recorded as they are observed and recapitulated clearly on the report sheet. - For any corrective action refer to the coordinator.

10.

SEQUENCE OF OPERATIONS
The sequence of operations is given by the report sheet.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 8

SHEET S1

Hardware checks

INITIAL STATUS: The site is operational.

ACTIONS: The installers inspect the premises in order to check that they comply with [A1] Site preparation and installation document. The following operations have to be performed: 1. 2. 3. 4. Upon arrival, read the safety guidelines specific to the site. Check that the number of units for each kind of items corresponds to the operation to be performed (refer to [A2] Packing list and Appendix 1 for the kit). Unpack each item. Fill in the report sheet.

FINAL STATUS: The hardware equipment delivered complies with the operations.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 9

SHEET S2

Site status checks

INITIAL STATUS: The S8000 outdoor BTS is on line.

ACTIONS: 1. 2. 3. Set up a phone link with the OMC technician and inform him that alarms will appear when opening the base radio cabinet front doors. Open the base radio cabinets front doors. Visually check the operating status of the site (see Appendix 2). LEDs on BCF front face: active CSWM: "RDY" and "ON" green LEDs on, passive CSWM: "RDY" green LED on but "ON" LED off, active GTW: "ON" green LED is on, active SYNC: "MASTER" green LED is on, no alarm on any SYNC or PCMI (if a PCMI card is connected to only one external PCM, a NOS alarm will illuminate a red LED on its front face). LEDs on CBCF front face: both CMCF : "+5V", "RDY" and "RUN" green LEDs on, active CMCF: "ABIS" and "ON" green LEDs on, no alarm on any CPCMI (if a CPCMI card is connected to only one external PCM, a NOS alarm will illuminate a red LED on its front face). LEDs on radio module front face: each DRX has the "+5V" and "DRX" green LEDs on. each PA has the "ALARM" LED green.

FINAL STATUS: The OMC technician and the commissioner have performed the initial checks.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 10

SHEET S3

Site shutdown

INITIAL STATUS: The site is in service

ACTIONS: There are three possible network configurations. See Figure 1:

DTI0

DTI1

BSC

star BTS

BTS
TEI 0

DTI0

DTI1

DTI0

DTI1

DTI0

DTI1

DTI0

DTI1

BSC

chained BTS

BTS
TEI 0

BTS
TEI 1

BTS
TEI 2

BTS
TEI 3

DTI0

DTI1

DTI0

DTI1

DTI0

DTI1

DTI0

DTI1

BSC

looped BTS

BTS
TEI 0

BTS
TEI 1

BTS
TEI 2

BTS
TEI 3

Figure 1: Network configurations 1. Ask the OMC-R technician to interrupt the BTS traffic by performing a soft shutdown, see Sheet LO2

If the BTS is chained or looped : 2. 3. Ask the OMC-R technician to interrupt the traffic of each dropped BTS by performing a soft shutdown, see Sheet LO2. Remove the blue straps on the PCMI or CPCMI board and make a short circuit as shown below.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 11

XL LP RL

XL LP RL

4. Ask the OMC-R technician to make the formerly shutdown BTSs return to service, see Sheet UN2.

FINAL STATUS: The site is interrupted to traffic and the initial cabinets are still powered on.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 12

SHEET S4

Cabinet power off

INITIAL STATUS: The site is shutdown

ACTIONS: 1. 2. 3. 4. If necessary, open the cabinet doors. Only for the base cabinet, turn off the PSCMD to power off the BCF ( see Appendix 2). Turn off each power amplifier and each F-type converter, ( see Appendix 2). With internal batteries : turn off the battery disconnect switch above the rectifiers, ( see Appendix 2).

With battery cabinet : open the doors, turn off the DC breaker, Appendix 4. 5. On the AC box turn off the following circuit breaker, see Appendix 3 : - Main circuit, - Climatic system, - Rectifier 6. Turn off the site breaker dedicated in the AC distribution customer box.

FINAL STATUS: The cabinet is powered off.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 13

SHEET S5

Equipment removing

INITIAL STATUS: The cabinet is powered off

ACTIONS: 1. 2. 3. 4. 5. 6. 7. 8. 9. Unlock the cabinet hood and open the hood to its vertical position. Remove filter cover plate and lid of the DACS. Disconnect the yellow/green cable on the lid of the DACS. Remove the transparent cover over the board. Remove the lid from the cable way at rear of the blower. Cut the cable ties. Unplug the blower cables from the control board ( connectors P4A and P4B) Undo the four screws around the flange of the blower A and remove the blower. Undo the four screws around the flange of the blower B and remove the blower.

10. Disconnect all other plugs to the control board (connectors P1, P2, P3, P5 and P6). 11. Sequentially release the plastics standoffs supporting the control board ( by depressing the top end of the standoffs) and remove the board.

FINAL STATUS: The control board and the blowers are removed.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 14

SHEET S6

Ambient air thermistor installation

INITIAL STATUS: The control board and the blowers are removed.

ACTIONS: See the Appendix 5 and Appendix 7. 1. 2. 3. 4. 5. 6. 7. 8. 9. Remove the filter DACS. Place the hole template in position. Mark the four holes through plate ( 3 on horizontal, 1 on vertical). Remove the hole template. Drill holes to diameters shown. Remove the cutting of metal. Fit grommets supplied to 6.5 DIA holes ( quantity 2). Push the thermistor through grommet A. Push the thermistor through grommet B.

10. Do not attach plug to connector P7 at this time. 11. Allow sufficient lead under fin block plate to attach thermistor to bracket. 12. Push the thermistor probe into grommet on bracket. 13. Push the wire into the clip on bracket. 14. Position the bracket under the front top channel and rivet it ( two rivets). 15. Pull excess thermistor cable back through grommet A and B.

FINAL STATUS: The ambient thermistor is installed in the DACS.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 15

SHEET S7

New equipments installation

INITIAL STATUS: The ambient thermistor is installed in the DACS.

ACTIONS: 1. 2. 3. Screw the replacement blowers into place using the eight screws. Mount the new board onto the plastic standoffs, ensuring that the LEDs are towards the top of the DACS. Check the position of the micro-switch [SW1] on the board is in compliance with the photo below.

First board version


Strap

SW1

Second board version


Position of the switch top

SW1

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

OFF

ON

Page 16

4.

Insert plugs P1, P2, P3, P5, P6 and P7, see Appendix 6.
WARNING: take care the correct

way of the connecteurs.

5. 6. 7. 8. 9.

Plug blower A (left hand from front of unit) into P4A and blower B into P4B. Push all wire harnesses into the cable trunking in a tidy fashion. Clamp the cable in the cable trunking. Replace trunking cover. Replace the plastic cover over the board.

10. Replace the filter. 11. Replace the DACS lid and filter cover plate. 12. Connect the yellow/green cable on the lid of the DACS. 13. Check the DACS is tidy and clean.

FINAL STATUS: The new equipments are installed.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 17

SHEET S8

Cabinet power up

INITIAL STATUS: The new equipments are installed.

ACTIONS: 1. 2. 3. For the cabinet, turn on : the site breaker dedicated. the climatic system breaker on the AC box. the rectifier breaker on the AC box (if necessary, check that the new rectifiers are powered). If battery backup used, turn on : the internal battery switch above the rectifiers, if internal batteries used the DC breaker (left), if battery cabinet used Turn on : each F-type converter the PSCMD to power on the BCF only for the base cabinet.

FINAL STATUS The cabinet is powered up.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 18

SHEET S9

Site return in service

INITIAL STATUS: The cabinet (s) is powered up.

ACTIONS: 1. 2. 3. 4. Ask the OMC-R technician to interrupt the traffic of each dropped BTS by performing a soft shutdown, refer to Sheet LO2. Remove the short circuit on the PCMI or CPCMI board and put the blue straps in theirs initial location. Ask the OMC technician to set all the site back to service, refer to Sheet UN2. Ask the OMC technician to unbar the Cells , and to enable the incomingHandover, see Sheet UN7.

FINAL STATUS: The site is in service.

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 19

SHEET S10

Final checks

INITIAL STATUS: The site is unlocked and enabled.

ACTIONS: 1. 2. 3. 4. 5. 6. 7. 8. 9. Stick the completed label on the DACS adjacent to the standard DACS identification label. Close and lock the hood of each cabinet. Close and lock the doors of each cabinet. Ask the OMC technician to check no alarms are remaining. Fill up the Report Sheet (Appendix 8). Let one copy on site and send one copy to the Coordinator. All non compliance have to be physically spotted on site and recapitulated on the Report Sheet. For any corrective action refer to the Coordinator. Release the phone link with the OMC-R technician. Leave the premises clean and tidy.

FINAL STATUS: The acoustic noise reduction kit is installed. The site is fully operational

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 20

Appendix 1 Kit components

Item

Quantity by kit

Blower DDC 0-10V Input Thermistor assy Thermistor bracket Clamp plastic Control assy Grommet PVC 6.4mm Standoff PCB Rivet pop steel Hole template Support plate Yellow insulated terminal

2 1 1 1 1 2 4 4 1 1 3

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 21

Appendix 2 Font view of the cabinet

Hood

Gas spring Open-hood EM sensor DACS

Battery box

User Compartment 6U
BCF location

PA location
1 2

DRX location AC Box

Type F converters

Battery disconnection switch

GND bar

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 22

Appendix 3 AC box general view


AC voltage to climatic system and heaters Climatic system circuit breaker (blue) Fuse for indicator light

Main AC power indicator light (green) Main circuit breaker (red) Alarm return to ALCO board Fuse for mains plugs

Two mains plugs

Cover Rectifier circuit breaker (blue) AC power to rectifiers Ground

AC lightning protector

Figure A : Single-phased AC box

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 23

AC voltage to climatic system and heaters Climatic system circuit breaker (blue) Fuse for indicator light

main AC power indicator light (green) Main circuit breaker (red) Alarm return to ALCO board

Fuse for mains plugs Two mains plugs

Rectifier circuit breaker (blue) AC power to rectifiers Ground

AC lightning protector

Figure B : Split single-phased AC box

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 24

AC voltage to climatic system and heaters

Alarm return to ALCO board

ACU0 circuit breaker

ACU1 circuit breaker (not used)

General stop button

Mains plugs circuit breaker

Two mains plugs

Cover Rectifier circuit breaker

AC voltage to rectifiers

Ground

AC lightning protector

Figure C : Tri-phased AC box

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 25

Appendix 4 Battery cabinet

Battery compartment + + -

Battery compartment + + -

Black

Battery compartment + + Bleu Blue

Ground terminal block

Battery compartment + DC panel + AC panel

-48V terminal block

Heating and ventilation unit

DC breaker HVU breaker

AC breaker

Plinth

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 26

Appendix 5 Thermistor installation

m : location of the hole with the template

Top view
Control board

6.5 dia 6.5 dia 3.5 dia

Hole template

To handrail for the hole template

6.5 dia

Front of the DACS

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 27

n Installation of the thermistor in the DACS


Top view
Control board

Thermistor

Gromet "A"

Gromet "B"

Front of the DACS

o Lateral view of the installation of the thermistor on its support

Thermistor

Grommet

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 28

Appendix 6 Control board

Control board

P2 P3 P1 : Cabinet air temperature P2 : AC supplies P3 : DC supplies P4A : Blower A P4B : Blower B P5 : Damper motor drive P6 : Alarms and filter clog switch P7 : Ambient air thermistor

P4A P4B

P5 P6

P1

P7

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 29

Appendix 7 View of the ambient thermistor final installation

Ambient thermistor Hole with 6.5 dia. Rivets

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 30

PROJECT:............................ SITE NAME:.......................

FOLIO /..... RECORD:...................

Appendix 8 Report sheet


The following parts MUST be filled by the coordinator before the site operation. Applicable documents: (new documents may be added) Project documentation plan [A1] Site preparation and installation [A2] Packing list [A3] V_ OMC-R operations called by I&C procedures : Reference .............................. Project document Project document

:
: : : :

PE/ICM/APP/00__

.......................................................

..............................

Note: Default Core methods reference are given in Applicable Documents paragraph.

Input parameters: (new parameters may be added) Network type: BTS type: GSM 900 GSM 1900

Y Y

GSM 1800

System release:

.......................... ..........................

..............

Type of connection of the BTS : Star ....................................................... ....................................................... .......................................................

Chained

BTS configuration: Looped

....................................................... ....................................................... .......................................................

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 31

PROJECT:............................ SITE NAME:.......................

FOLIO /..... RECORD:...................

In the action following chart, To Use? column MUST be filled by the coordinator before the site operation.
Action Hardware checks Site status checks Site shutdown Condition To USE? Sheet SITE S1 S2 S3 LO2, UN2 Sheet OMC OK NOK

;. ;. ;. ;. ;. ;. ;. ;. ;. ;.

Cabinet power off Equipment removing Ambient air thermistor installation New equipments installation Cabinet power up

S4 S5 S6

S7

S8

Site return in service

S9

LO2, UN2 UN7,

Final checks

S10

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99

Page 32

PROJECT:............................ SITE NAME:.......................

FOLIO /..... RECORD:...................

The following parts MUST be filled by the commissioner during the site operation. Additional results: Base cabinet : Serial Number :.............. Extension 1 cabinet : Serial Number :.............. Extension 2 cabinet : Serial Number :..............
Comments:

Sign off :
Coordinator Company name Functions Name Signature Date Commissioner Customer representative

Z END OF DOCUMENT Y

This confidential document is the property of NORTEL MATRA CELLULAR and should not be copied or circulated without permission.

S8000 OUTDOOR : NOISE REDUCTION KIT IN DACS INSTALLATION PE/ICM/APP/0255 VERSION 01.04/EN OF 16/06/99