| AUTOMATION

MiCOM ALSTOM P14x


Feeder Management Relay
Software Version: 44 Hardware Version: J

Technical Data Sheet


P14x/EN TDS/Fe7
This document should be read alongside the Technical Manual

GRID

Note:

The technical manual for this device gives instructions for its installation, commissioning, and operation. However, the manual cannot cover all conceivable circumstances or include detailed information on all topics. In the event of questions or specific problems, do not take any action without proper authorization. Contact the appropriate Alstom Grid technical sales office and request the necessary information. Any agreements, commitments, and legal relationships and any obligations on the part of Alstom Grid including settlements of warranties, result solely from the applicable purchase contract, which is not affected by the contents of the technical manual. This device MUST NOT be modified. If any modification is made without the express permission of Alstom Grid, it will invalidate the warranty, and may render the product unsafe.

The Alstom Grid logo and any alternative version thereof are trademarks and service marks of Alstom Grid. MiCOM is a registered trademark of Alstom Grid. All trade names or trademarks mentioned herein whether registered or not, are the property of their owners. This manual is provided for informational use only and is subject to change without notice. 2010, Alstom Grid. All rights reserved.

Technical Data
Mechanical Specifications
Design Modular MiCOM Px40 platform relay, P141/142/P144-40TE (206mm (8)) case and P143/P145 (309.6mm (12)) case. Mounting is front of panel flush mounting, or 19 rack mounted (ordering options). Enclosure Protection Per IEC 60529: 1992 IP 52 Protection (front panel) against dust and dripping water. IP 50 Protection for the rear and sides of the case against dust. IP 10 Product safety protection for the rear due to live connections on the terminal block. Weight Case 40TE: approx. 7.3 kg Case 60TE: approx. 9.2 kg

Rear Communications Port EIA(RS)485 signal levels, two wire Connections located on general purpose block, M4 screw. For screened twisted pair cable, multi-drop, 1000m max. For K-Bus, IEC-870-5-103, or DNP3 protocol (ordering options). Isolation to SELV level. Optional Second Rear Communications Port EIA(RS)232, 9 pin D-type female connector, socket SK4. Courier protocol: K-Bus, EIA(RS)232, or EIA(RS)485 connection. Isolation to SELV level. Optional Rear IRIG-B Interface modulated or un-modulated BNC socket Isolation to SELV level. 50 ohm coaxial cable. Optional Rear Fiber Connection for SCADA/DCS BFOC 2.5 -(ST)-interface for glass fiber, as per IEC 874-10. 850nm short-haul fibers, one Tx and one Rx. For Courier, IEC-870-5-103, DNP3 or MODBUS protocol (ordering options). Optional Rear Ethernet Connection for IEC 61850 or DNP3.0 Optional redundant Rear Ethernet Connection (optical) 10BaseT/100BaseTX Communications Interface in accordance with IEEE802.3 and IEC 61850 Isolation: 1.5kV Connector type: RJ45 Cable type: Screened Twisted Pair (STP) 100 Base FX Interface Interface in accordance with IEEE802.3 and IEC 61850 Wavelength: 1300nm Fiber: multi-mode 50/125m or 62.5/125m Connector style: BFOC 2.5 -(ST)

Terminals
AC Current and Voltage Measuring Inputs Located on heavy duty (black) terminal block: Threaded M4 terminals, for ring lug connection. CT inputs have integral safety shorting, upon removal of the terminal block. General Input/Output Terminals For power supply, opto inputs, output contacts and COM1 rear communications. Located on general purpose (grey) blocks: Threaded M4 terminals, for ring lug connection. Case Protective Earth Connection Two rear stud connections, threaded M4. Must be earthed (grounded) for safety, 2 minimum earth wire size 2.5mm . Front Port Serial PC Interface EIA(RS)232 DTE, 9 pin D-type female connector. Courier protocol for interface to S1 software. Isolation to ELV level. Maximum cable length 15m. Front Download/Monitor Port EIA(RS)232, 25 pin D-type female connector. For firmware downloads. Isolation to ELV level.

Ratings
AC Measuring Inputs Nominal frequency: 50 and 60 Hz (settable) Operating range: 45 to 65Hz Phase rotation: ABC 8
P141/2/3/4/5 Software Version 44J

P14x Technical Data Sheet

AC Current Nominal current (In): 1 and 5 A dual rated. (1A and 5A inputs use different transformer tap Connections, check correct terminals are wired). Nominal burden per phase: < 0.15 VA at In Thermal withstand: continuous 4 In for 10s: 30 In for 1s; 100 In Linear to 64 In (non-offset AC current). AC Voltage Nominal voltage (Vn): 100 to 120 V or 380 to 480V phase-phase (min. 196 Vac, max. 560 Vac). Nominal burden per phase: < 0.02 VA at Vn. Thermal withstand: continuous 2 Vn for 10s: 2.6 Vn

Battery Backup Front panel mounted Type AA, 3.6V (SAFT advanced battery reference LS14250) Battery life (assuming relay energized for 90% time) >10 years Field Voltage Output Regulated 48Vdc Current limited at 112mA maximum output Digital (Opto) Inputs Universal opto inputs with programmable voltage thresholds (24/27, 30/34, 48/54, 110/125, 220/250V). May be energized from the 48V field voltage, or the external battery supply. Rated nominal voltage: 24 to 250Vdc Operating range: 19 to 265Vdc Withstand: 300Vdc, 300Vrms. Peak current of opto input when energized is 3.5mA (0-300V) Nominal pick-up and reset thresholds: Nominal battery 24/27: 60 - 80% DO/PU (logic 0) <16.2 (logic 1) >19.2 Nominal battery 24/27: 50 - 70% DO/PU (logic 0) <12.0 (logic 1) >16.8 Nominal battery 30/34: 60 - 80% DO/PU (logic 0) <20.4 (logic 1) >24.0 Nominal battery 30/34: 50 - 70% DO/PU (logic 0) <15.0 (logic 1) >21.0 Nominal battery 48/54: 60 - 80% DO/PU (logic 0) <32.4 (logic 1) >38.4 Nominal battery 48/54: 50 - 70% DO/PU (logic 0) <24.0 (logic 1) >33.6 Nominal battery 110/125: 60 - 80% DO/PU (logic 0) <75.0 (logic 1) >88.0 Nominal battery 110/125: 50 - 70% DO/PU (logic 0) <55.0 (logic 1) >77.0 Nominal battery 220/250: 60 - 80% DO/PU (logic 0) <150.0 (logic 1) >176.0 Nominal battery 220/250: 50 - 70% DO/PU (logic 0) <110 (logic 1) >154 Recognition time: <2ms with long filter removed, <12ms with half cycle ac immunity filter on

Power Supply
Auxiliary Voltage (Vx) Three ordering options: (i) Vx: 24 to 48 Vdc (ii) Vx: 48 to 110 Vdc, and 40 to 100Vac (rms) (iii) Vx: 110 to 250 Vdc, and 100 to 240Vac (rms) Operating Range (i) 19 to 65V (dc only for this variant) (ii) 37 to 150V (dc), 32 to 110V (ac) (iii) 87 to 300V (dc), 80 to 265V (ac) With a tolerable ac ripple of up to 12% for a dc supply, per IEC 60255-11: 1979. Nominal Burden Quiescent burden: 11W. (Extra 1.25W when fitted with second rear Courier) Additions for energized binary inputs/outputs: Per opto input: 0.09W (24 to 54V), 0.12W (110/125V), 0.19W (220/120V). Per energized output relay: 0.13W Power-up Time Time to power up < 11s. Power Supply Interruption Per IEC 60255-11: 1979 The relay will withstand a 20ms interruption in the DC auxiliary supply, without de-energizing. Per IEC 61000-4-11: 1994 The relay will withstand a 20ms interruption in an AC auxiliary supply, without de-energizing.
P14x Technical Data Sheet

Output Contacts
Standard Contacts General purpose relay outputs for signaling, tripping and alarming: Continuous Carry Ratings (Not Switched): Maximum continuous current: 10A (UL: 8A) Short duration withstand carry: 30A for 3s 250A for 30ms Rated voltage: 300 V Make & Break Capacity: DC: 50W resistive DC: 62.5W inductive (L/R = 50ms) AC: 2500VA resistive (cos = unity) 9
P141/2/3/4/5 Software Version 44J

AC: 2500VA inductive (cos = 0.7) Make, Carry: 30A for 3 secs, dc resistive, 10,000 operations (subject to the above limits of make/break capacity and rated voltage) Make, Carry & Break: 30A for 200ms, ac resistive, 2,000 operations (subject to the above limits of make/break capacity & rated voltage) 4A for 1.5 secs, dc resistive, 10,000 operations (subject to the above limits of make/break capacity & rated voltage) 0.5A for 1 sec, dc inductive, 10,000 operations (subject to the above limits of make/break capacity & rated voltage) 10A for 1.5 secs, ac resistive/inductive, 10,000 operations (subject to the above limits of make/break capacity & rated voltage) Durability: Loaded contact:

make/break capacity & rated voltage) 10A (*), dc inductive, 10,000 operations (subject to the above limits of make/break capacity & rated voltage) *Typical for repetitive shots - 2 minutes idle for thermal dissipation
Voltage 65V 150V 250V 250V Current 10A 10A 10A 10A L/R 40ms 40ms 40ms 20ms No. of Shots in 1 sec 5 4 2 4

MOV protection: Max Voltage 330V dc Durability: Loaded contact: 10 000 operations minimum Unloaded contact: 100 000 operations minimum

10 000 operations minimum Unloaded contact: 100 000 operations minimum

Operate Time: Less than 0.2ms Reset Time: Less than 8ms Watchdog Contacts Non-programmable contacts for relay healthy/relay fail indication: Breaking capacity: DC: 30W resistive DC: 15W inductive (L/R = 40ms) AC: 375VA inductive (cos = 0.7) IRIG-B 12X Interface (Modulated) External clock synchronization per IRIG standard 200-98, format B12X. Input impedance 6k at 1000Hz Modulation ratio: 3:1 to 6:1 Input signal, peak-peak: 200mV to 20V IRIG-B 00X Interface (Un-modulated) External clock synchronization per IRIG standard 200-98, format B00X. Input signal TTL level Input impedance at dc 10k

Operate Time Less than 5ms Reset Time Less than 5ms High Break Contacts (Model D Only) Continuous Carry Ratings (Not Switched): Maximum continuous current: 10A Short duration withstand carry: 30A for 3s 250A for 30ms Rated voltage: 300 V Make & Break Capacity: DC: 7500W resistive DC: 2500W inductive (L/R = 50ms) Make, Carry: 30A for 3 secs, dc resistive, 10,000 operations (subject to the above limits of make/break capacity & rated voltage) Make, Carry & Break: 30A for 3 secs, dc resistive, 5,000 operations (subject to the above limits of make/break capacity & rated voltage) 30A for 200 ms, dc resistive, 10,000 operations (subject to the above limits of
P14x Technical Data Sheet

Environmental Conditions
Ambient Temperature Range Per IEC 60255-6: 1988 Operating temperature range: -25C to +55C (or -13F to +131F). Storage and transit: -25C to +70C (or -13F to +158F). 10
P141/2/3/4/5 Software Version 44J

Ambient Humidity Range Per IEC 60068-2-3: 1969: 56 days at 93% relative humidity and +40C Per IEC 60068-2-30: 1980: Damp heat cyclic, six (12 + 12) hour cycles, 93% RH, +25 to +55C Corrosive Environments Per IEC 60068-2-60: 1995, Part 2, Test Ke, Method (class) 3 Industrial corrosive environment/poor environmental control, mixed gas flow test. Industrial corrosive environment 21 days at 75% relative humidity and +30C exposure to elevated concentrations of H2S, NO2, Cl2, SO2

Electromagnetic Compatibility (EMC)


1 MHz Burst High Frequency Disturbance Test Per IEC 60255-22-1: 1988, Class III, Common-mode test voltage: 2.5 kV, Differential test voltage: 1.0 kV, Test duration: 2s, Source impedance: 200 EIA(RS)232 ports excepted. 100kHz Damped Oscillatory Test Per EN61000-4-18: 2007: Level 3 Common mode test voltage: 2.5kV Differential mode test voltage: 1kV Immunity to Electrostatic Discharge Per IEC 60255-22-2: 1996, Class 4, 15kV discharge in air to user interface, display, and exposed metalwork. Per IEC 60255-22-2: 1996, Class 3, 8kV discharge in air to all communication ports. 6kV point contact discharge to any part of the front of the product. Electrical Fast Transient or Burst Requirements Per IEC 60255-22-4: 2002. Test severity Class III and IV: Amplitude: 2 kV, burst frequency 5kHz (Class III), Amplitude: 4 kV, burst frequency 2.5kHz (Class IV). Applied directly to auxiliary supply, and applied to all other inputs. EIA(RS)232 ports excepted. Surge Withstand Capability IEEE/ANSI C37.90.1:2002: 4kV fast transient and 2.5kV oscillatory applied common mode and differential mode to opto inputs (filtered), output relays, CTs, VTs, power supply, field voltage. 4kV fast transient and 2.5kV oscillatory applied common mode to communications, IRIG- B. Surge Immunity Test EIA(RS)232 ports excepted. Per IEC 61000-4-5: 2005 Level 4, Time to half-value: 1.2/50 s, Amplitude: 4kV between all groups and case earth, Amplitude: 2kV between terminals of each group. Immunity to Radiated Electromagnetic Energy Per IEC 60255-22-3: 2000, Class III:

Type Tests
Insulation Per IEC 60255-27: 2005 Insulation resistance > 100M at 500Vdc (Using only electronic/brushless insulation tester). Creepage Distances and Clearances Per EN 61010-1: 2001 Pollution degree 2, Overvoltage category III, Impulse test voltage 5 kV. High Voltage (Dielectric) Withstand EIA(RS)232 ports excepted. (i) Per IEC 60255-27: 2005, 2 kV rms AC, 1 minute: Between all case terminals connected together, and the case earth. Also, between all terminals of independent circuits. 1kV rms AC for 1 minute, across open watchdog contacts. 1kV rms AC for 1 minute, across open contacts of changeover output relays. (ii) Per ANSI/IEEE C37.90-1989 (reaffirmed 1994): 1.5 kV rms AC for 1 minute, across open contacts of changeover output relays. Impulse Voltage Withstand Test Per IEC 60255-27: 2005 Front time: 1.2 s, Time to half-value: 50 s, Peak value: 5 kV, 0.5J Between all terminals, and all terminals and case earth.

P14x Technical Data Sheet

11

P141/2/3/4/5 Software Version 44J

Test field strength, frequency band 80 to 1000 MHz: 10 V/m, Test using AM: 1 kHz / 80%, Spot tests at 80, 160, 450, 900 MHz Per IEEE/ANSI C37.90.2: 1995: 25MHz to 1000MHz, zero and 100% square wave modulated. Field strength of 35V/m. Radiated Immunity from Digital Communications Per EN61000-4-3: 2002, Level 4: Test field strength, frequency band 800 to 960 MHz, and 1.4 to 2.0 GHz: 30 V/m, Test using AM: 1 kHz / 80%. Radiated Immunity from Digital Radio Telephones Per ENV 50204: 1995 10 V/m, 900MHz and 1.89GHz. Immunity to Conducted Disturbances Induced by Radio Frequency Fields Per IEC 61000-4-6: 1996, Level 3, Disturbing test voltage: 10 V Power Frequency Magnetic Field Immunity Per IEC 61000-4-8: 1994, Level 5, 100A/m applied continuously, 1000A/m applied for 3s. Per IEC 61000-4-9: 1993, Level 5, 1000A/m applied in all planes. Per IEC 61000-4-10: 1993, Level 5, 100A/m applied in all planes at 100kHz/1MHz with a burst duration of 2s.

Compliance to the European Commission Directive on EMC is claimed via the Technical Construction File route. Product Specific Standards were used to establish conformity: EN50263: 2000 Product Safety Per 2006/95/EC: Compliance to the European Commission Low Voltage Directive. (LVD) is demonstrated using a Technical File. A product specific standard was used to establish conformity. EN 60255-27: 2005

R&TTE Compliance Radio and Telecommunications Terminal Equipment (R&TTE) directive 99/5/EC. Compliance demonstrated by compliance to both the EMC directive and the Low voltage directive, down to zero volts. Applicable to rear communications ports. ATEX Compliance ATEX Potentially Explosive Atmospheres directive 94/9/EC, for equipment. The equipment is compliant with Article 1(2) of European directive 94/9/EC. It is approved for operation outside an ATEX hazardous area. It is however approved for connection to Increased Safety, Ex e, motors with rated ATEX protection, Equipment Category 2, to ensure their safe operation in gas Zones 1 and 2 hazardous areas. CAUTION - Equipment with this marking is not itself suitable for operation within a potentially explosive atmosphere.

Conducted Emissions Per EN 55022: 1998: Class A: 0.15 - 0.5MHz, 79dBV (quasi peak) 66dBV (average) 0.5 - 30MHz, 73dBV (quasi peak) 60dBV (average). Radiated Emissions Per EN 55022: 1998: Class A: 30 - 230MHz, 40dBV/m at 10m measurement distance 230 - 1GHz, 47dBV/m at 10m measurement distance.

Compliance demonstrated by Notified Body certificates of compliance.

II (2) G

Mechanical Robustness
Vibration Test Per IEC 60255-21-1: 1996 Response Class 2 Endurance Class 2 Shock and Bump Per IEC 60255-21-2: 1995 Shock response Class 2 12
P141/2/3/4/5 Software Version 44J

EU Directives
EMC Compliance Per 89/336/EEC:
P14x Technical Data Sheet

Shock withstand Class 1 Bump Class 1 Seismic Test Per IEC 60255-21-3: 1995 Class 2

P14x Third Party Compliances Underwriters Laboratory (UL)

File Number: E202519 Issue Date: 21-04-2005 (Complies with Canadian and US requirements). Energy Networks Association (ENA)

Certificate Number: 101 Issue 3 Assessment Date: 10-12-2004 Type (s): P141, P142, P143 & P145

P14x Technical Data Sheet

13

P141/2/3/4/5 Software Version 44J

Protection Functions
Three Phase Overcurrent Protection
Accuracy Additional tolerance X/R ratios: 5% over X/R 190 Overshoot: <30ms

DT reset: 2% or 50ms whichever is greater Repeatability: 5% * Reference conditions TMS = 1, TD = 1 and IN > setting of 1A, operating range 2-20In SEF DT Pick-up: Setting 5% Minimum IDMT Trip level: 1.05 x Setting 5% Drop-off: 0.95 x Setting 5% IDMT shape: 5% or 40ms whichever is greater * IEEE reset: 7.5% or 60ms whichever is greater DT operation: 2% or 50ms whichever is greater DT reset: 5% Repeatability: 5% * Reference conditions TMS = 1, TD = 1 and IN > setting of 100mA, operating range 2-0In REF Pick-up: Setting formula 5% Drop-off: 0.80 x setting formula 5% Operating time: <60ms High pick up: Setting 5% High operating time: <30ms Repeatability: <15% Wattmetric SEF Pick-up For P=0W ISEF> 5% or P> 5% Drop off: For P>0W (0.95 x ISEF>) 5% or 0.9 x P> 5% Boundary accuracy: 5% with 1 hysteresis Repeatability: 5% SEF Cos(PHI)/ Pick-up: Setting 5% for angles RCA60 Drop-off: 0.90 x Setting IDMT shape: 5% or 50ms whichever is greater * IEEE reset: 7.5% or 60ms whichever is greater DT operation: 2% or 50ms whichever is greater DT reset: 5% Repeatability: 2% * Reference conditions TMS = 1, TD = 1 and IN > setting of 100mA, operating range 2-0In SEF Sin(PHI) Pick-up: Setting 5% for angles from RCA60 to RCA90 Drop-off: 0.90 x Setting IDMT shape: 5% or 50ms whichever is greater * 14
P141/2/3/4/5 Software Version 44J

Inverse Time Characteristic


Accuracy DT Pick-up: Setting 5% Minimum IDMT trip level: 1.05 x setting 5% Drop-off: 0.95 x setting 5% IDMT shape: 5% or 40ms whichever is greater IEEE reset: 5% or 50ms whichever is greater DT operation: 2% or 50ms, whichever is greater DT reset: 5% Directional boundary (RCA 90%): 2% hysteresis 2 Characteristic: UK curves IEC 60255-3 1998 US curves: IEEEC37.1121996

Earth/Sensitive Fault Protection


Earth Fault 1 DT Pick-up: Setting 5% Minimum IDMT trip level: 1.05 x Setting 5% Drop-off: 0.95 x Setting 5% IDMT shape: 5% or 40ms whichever is greater * IEEE reset: 5% or 50ms whichever is greater DT operation: 2% or 50ms whichever is greater DT reset: 5% Repeatability: 2.5% * Reference conditions TMS = 1, TD = 1 and IN> setting of 1A operating range 2-20In Earth Fault 2 DT Pick-up: Setting 5% Minimum IDMT Trip level: 1.05 x Setting 5% Drop-off: 0.95 x Setting 5% IDMT shape: 5% or 40ms whichever is greater * IEEE reset: 10% or 40ms whichever is greater DT operation: 2% or 50ms whichever is greater
P14x Technical Data Sheet

IEEE reset: 7.5% or 60ms whichever is greater DT operation: 2% or 50ms whichever is greater DT reset: 5% Repeatability: 2% Reference conditions TMS = 1, TD = 1 and IN > setting of 100mA, operating range 2-0In Zero Polarizing Operating pick-up: 2% of RCA 90% Hysteresis: <3 VN > Pick-up: Setting 10% VN > Drop-off: 0.9 x Setting 10% Negative Polarizing Operating Pick-up: 2% of RCA 90% Hysteresis: <3 VN 2 > Pick-up: Setting 10% VN 2 > Drop-off: 0.9 x Setting 10% I2 > Pick up: Setting 10% I2 > Drop-off: 0.9 x Setting 10%

Operating time: 2% or 50ms whichever is greater Repeatability: <5% Disengagement time: <50ms tRESET: 5% Instantaneous operating time: < 50ms

Sensitive Reverse/Low Forward/ Over Power (1 Phase)


Accuracy Pick-up: Setting 10% Reverse/Over power Drop-off: 0.9 of setting 10% Low forward power Drop-off: 1.1 of Setting 10% Angle variation Pick-up: Expected pick-up angle 2 degree Angle variation Drop-off: Expected drop-off angle 2.5% degree Operating time: 2% or 50ms whichever is greater Repeatability: <5% Disengagement time: <50ms tRESET: 5% Instantaneous operating time: <50ms

Negative Sequence Overcurrent


Accuracy DT Pick-up: Setting 5% Minimum IDMT trip level: 1.05 x Setting 5% Drop-off: 0.95 x Setting 5% IDMT shape: 5% or 40ms whichever is greater IEEE reset: 5% or 50ms whichever is greater DT operation: 2% or 50ms, whichever is greater DT reset: 5% Directional boundary (RCA 90%): 2% hysteresis 2 Characteristic: UK curves IEC 60255-3 1998 US curves: IEEEC37.1121996

Under Voltage Protection


Accuracy DT Pick-up: Setting 5% IDMT Pick-up: Setting 5% Drop-off: 1.02 x Setting 5% IDMT shape: 2% or 50ms whichever is greater DT operation: 2% or 50ms whichever is greater Reset: <75ms Repeatability: <1%

Over Voltage Protection


Accuracy DT Pick-up: Setting 5% IDMT Pick-up: Setting 5% Drop-off: 0.98 x Setting 5% IDMT shape: 2% or 50ms whichever is greater DT operation: 2% or 50ms whichever is greater Reset: <75ms Repeatability: <1%

Reverse/Low Forward/Over Power Protection


Accuracy Pick-up: Setting 10% Reverse/Over Power drop off: 0.95 x Setting 10% Low forward Power drop off: 1.05xSetting+10% Angle variation pick-up: Expected pick-up angle 2 degree Angle variation drop-off: Expected drop-off angle 2.5 degree

P14x Technical Data Sheet

15

P141/2/3/4/5 Software Version 44J

Rate of Change of Voltage dv/dt Protection


Accuracy for 110V VT Tolerance: 1% or 0.07, whichever is greater Pick-up: Setting tolerance Drop-off: (Setting - 0.07) tolerance for positive direction Drop-off: (Setting + 0.07) tolerance for negative direction Operating time@50Hz: [(Avg.cycle*20)+60]ms Reset time@50Hz: 40ms

Operating timer: 2% or 50ms whichever is greater Operating & Reset Time Operating time* (underfrequency): <100ms for Fs/Ff ratios less than 2 <160ms for Fs/Ff ratios less than 6 <230ms otherwise Operating time* (overfrequency): <125ms for Fs/Ff ratios less than 2 <150ms for Fs/Ff ratios less than 30 <200ms otherwise Reset time*: <200ms * Reference conditions: Tested using step changes in frequency with Freq.Av.Cycles setting = 0 and no intentional time delay. Fs/Ff ratios as stated, where: Fs = start frequency - frequency setting Ff = frequency setting - end frequency

Neutral Displacement/Residual Voltage


Accuracy Pick-up: Setting 5% or 1.05 x Setting 5% Drop-off: 0.95 x Setting 5% IDMT shape: 5% or 65ms whichever is greater DT operation: 2% or 20ms whichever is greater <55ms Reset: <35ms Repeatability: <10%

Advanced Frequency Supervised Rate of Change of Frequency f+df/dt Protection [81RF]


Accuracy Pick-up: Setting10mHz (frequency threshold) Setting 3% or 10mHz/s, whichever is greater (df/dt threshold) Drop-off (frequency threshold): Setting +20mHz, 10mHz (underfrequency) Setting -20mHz, 10mHz (overfrequency) Drop-off (df/dt threshold, falling frequency): Setting +0.005Hz/s, 10mHz/s (for settings between 0.01Hz/s and 0.1Hz/s) Setting +0.05Hz/s, 5% or 55mHz/s, whichever is greater (for settings greater than 0.1Hz/s) Drop-off (df/dt threshold, rising frequency): Setting -0.005Hz/s, 10mHz/s (for settings between 0.01Hz/s and 0.1Hz/s) Setting -0.05Hz/s, 5% or 55mHz/s, whichever is greater (for settings greater than 0.1Hz/s) Operating & Reset Time Instantaneous operating time: <125ms for Freq.Av.Cycles setting = 0 Reset time: <400ms for df/dt.Av.Cycles setting = 0

Under-frequency Protection
Accuracy Pick-up: Setting 0.025Hz Drop-off: 1.05 x Setting 0.025Hz DT operation: 2% or 50ms whichever is greater * * The operating time will also include a time for the relay to frequency track (20Hz/second)

Over-frequency Protection
Accuracy Pick-up: Setting 0.025Hz Drop-off: 0.95 x Setting 0.025Hz DT operation: 2% or 50ms whichever is greater * * The operating will also include a time for the relay to frequency track (20Hz/ second)

Advanced Over/Under Frequency f+t Protection [81U/81O]


Accuracy Pick-up: Setting10mHz Drop-off: Setting +20mHz, 10mHz (underfrequency) Setting -20mHz, 10mHz (overfrequency)

P14x Technical Data Sheet

16

P141/2/3/4/5 Software Version 44J

Advanced Independent Rate of Change of Frequency df/dt+t Protection [81R]


Accuracy Pick-up: Setting 3% or 10mHz/s, whichever is greater Drop-off (falling frequency): Setting +0.005Hz/s, 10mHz/s (for settings between 0.01Hz/s and 0.1Hz/s) Setting +0.05Hz/s, 5% or 55mHz/s, whichever is greater (for settings greater than 0.1Hz/s) Drop-off (rising frequency): Setting -0.005Hz/s, 10mHz/s (for settings between 0.01Hz/s and 0.1Hz/s) Setting -0.05Hz/s, 5% or 55mHz/s, whichever is greater (for settings greater than 0.1Hz/s) Operating timer: 2% or 50ms whichever is greater Operating & Reset Time Operating time*: <200ms for ramps 2x setting or greater <300ms for ramps 1.3x setting or greater Reset time*: <250ms * Reference conditions: Tested with df/dt.Av.Cycles setting = 0, for df/dt settings greater than 0.1Hz/s (positive or negative, as relevant) and no intentional time delay.

Advanced Load Restoration


Accuracy Pick-up: Setting10mHz Drop-off: Setting -20mHz, 10mHz Restoration timer: 2% or 50ms whichever is greater Holding timer: 2% or 50ms whichever is greater

Broken Conductor Logic


Accuracy Pick-up: Setting 2.5% Drop-off: 0.95 x Setting 2.5% DT operation: 2% or 40ms whichever is greater

Thermal Overload
Accuracy Thermal alarm pick-up: Calculated trip time 10% Thermal overload pick-up: Calculated trip time 10% Cooling time accuracy: 15% of theoretical Repeatability: <5% * Operating time measured with applied current of 20% above thermal setting.

Voltage Controlled Overcurrent


Accuracy VCO threshold Pick-up: Setting 5% Overcurrent Pick-up: (K factor x Setting) 5% VCO threshold Drop-off: 1.05 x Setting 5% Overcurrent Drop-off: 0.95 x (K factor x Setting) 5% Operating time: 5% or 60ms whichever is greater Repeatability: <5%

Advanced Average Rate of Change of Frequency f+Df/Dt Protection [81RAV]


Accuracy Pick-up: Setting10mHz (frequency threshold) Setting 0.1Hz/s (Df/Dt threshold)* Drop-off: Setting +20mHz, 10mHz (falling frequency) Setting -20mHz, 10mHz (rising frequency) Operating timer: 2% or 30ms whichever is greater * Reference conditions: To maintain accuracy the minimum time delay setting, Dt, should be: Dt > 0.375 x Df + 0.23 (for Df setting < 1Hz) Dt > 0.156 x Df + 0.47 (for Df setting 1Hz) Operating Time Typically <125ms with Freq.Av.Cycles = 0

Cold Load Pick-up Setting


Accuracy I> Pick-up: Setting 1.5% I> Pick-up: Setting 2.5% IN> Pick-up: Setting 1.5% I> Drop-off: 0.95 x Setting 1.5% I> Drop-off: 0.95 x Setting 2.5% IN> Drop-off: 0.95 x Setting 1.5% DT operation: 0.5% or 40ms whichever is greater Repeatability: <1% 17
P141/2/3/4/5 Software Version 44J

P14x Technical Data Sheet

Negative Sequence Overvoltage Protection


Accuracy Pick-up: Setting 5% Drop-off: 0.95 x Setting 5% DT operation: 2% or 50ms whichever is greater Repeatability: <5%

Programmable Scheme Logic


Accuracy Output conditioner timer: Setting 2% or 50ms whichever is greater Dwell conditioner timer: Setting 2% or 50ms whichever is greater Pulse conditioner timer: Setting 2% or 50ms whichever is greater

Admittance, Conductance and Susceptance


Accuracy YN, BN and BN measurements: 5% YN, BN, BN Pick-up: Setting 5% YN, BN, BN Drop-off: >0.85 x Setting Operating time: Start <100ms Trip Setting 2% or 50 ms Operating boundary: 2 VN: Setting 5%

Measurements and Recording Facilities


Measurements Current: 0.05 3In Accuracy: 1.0% of reading Voltage: 0.052Vn Accuracy: 1.0% of reading Power (W): 0.22Vn 0.053In Accuracy: 5.0% of reading at unity power factor Reactive Power (Vars): 0.22Vn, 0.053In Accuracy: 5.0% of reading at zero power factor Apparent Power (VA): 0.22Vn 0.053In Accuracy: 5% of reading Energy (Wh): 0.22Vn 0.23In Accuracy: 5% of reading at zero power factor Energy (Varh): 0.22Vn 0.23In Accuracy: 5% of reading at zero power factor Phase accuracy: 0360 0.5 Accuracy: 0.5% Frequency: 4565Hz Accuracy: 0.025Hz Performance Year 2000: Compliant Real time clock accuracy: <2% seconds/day Modulation ratio: 1/3 or 1/6 Input signal peak-peak amplitude: 200mV20V Input impedance at 1000Hz: 6000 External clock synchronization: Conforms to IRIG standard 200-98, format B

Selective Overcurrent Protection


Accuracy Fast block operation: <25ms Fast block reset: <30ms Time delay: Setting 2% or 20ms whichever is greater

Voltage Transformer Supervision


Accuracy Fast block operation: <25ms Fast block reset: <30ms Time delay: Setting 2% or 20ms whichever is greater

Current Transformer Supervision


Accuracy In> Pick-up: Setting 5% VN< Pick-up: Setting 5% In> Drop-off: 0.9 x Setting 5% VN< Drop-off: (1.05 x Setting 5% or 1V whichever is greater Time delay operation: Setting 2% or 20ms whichever is greater CTS block operation: <1 cycle CTS reset: <35ms

IRIG-B and Real Time Clock


Accuracy (for modulated and un-modulated versions) Real time clock accuracy: < 2 seconds/day

P14x Technical Data Sheet

18

P141/2/3/4/5 Software Version 44J

Disturbance Records
Accuracy Magnitude and relative phases: 5% of applied quantities Duration: 2% Trigger position: 2% (minimum Trigger 100ms) Line length: 0.011000kn ** Line impedance (100/110V): 0.1/In250/In Line impedance (380/480V): 0.4/In1000/In Line angle: 2085 KZN residual: 07.00 KZN res. angle: -90+90

Receiver Optical Characteristics (TA = 0C to 70C, VCC = 4.75 V to 5.25 V)


Parameter Input Optical Power Minimum at Window Edge Input Optical Power Minimum at Eye Center Input Optical Power Maximum Sym PIN Min. (W) PIN Min. (C) PIN Max. -14 Min. Typ. -33.5 Max. -31 Unit dBm avg. Bm avg. dBm avg.

-34.5

-31.8

-11.8

Note: The 10BaseFL connection will no longer be supported as IEC 61850 does not specify this interface

Plant Supervision
Accuracy Timers: 2% or 20ms whichever is greater Broken current accuracy: 5% Timer Accuracy Timers: 2% or 40ms whichever is greater Reset time: <30ms Undercurrent Accuracy Pick-up: 10% or 25mA whichever is greater Operating time: <20ms Reset: <25ms

IEC 61850 Ethernet Data


100 Base FX Interface Transmitter Optical Characteristics (TA = 0C to 70C, VCC = 4.75 V to 5.25 V)
Parameter Output Optical Power BOL 62.5/125 m, NA = 0.275 Fiber EOL Output Optical Power BOL 50/125 m, NA = 0.20 Fiber EOL Optical Extinction Ratio Output Optical Power at Logic 0 State PO (0) Sym Min. -19 -20 22.5 23.5 Typ. 16.8 Max Unit dBm avg.

PO

-14

PO

20.3

-14

dBm avg.

10 -10 -45

% dB dBm avg

BOL - Beginning of life EOL - End of life

P14x Technical Data Sheet

19

P141/2/3/4/5 Software Version 44J

Settings, Measurements and Records List


Settings List Global Settings (System Data)
Language: English/French/German/Spanish Frequency: 50/60Hz

DST End Month: DST End Mins: RP1 Time Zone: RP2 Time Zone: Tunnel Time Zone:

Jan/Feb/Mar/Apr/May/ Jun/Jul/Aug/Sept/Oct/ Nov/Dec 0min1425min UTC/Local UTC/Local UTC/Local

Configuration
Setting Group: Select via Menu Select via Opto Active Settings: Group 1/2/3/4 Setting Group 1: Disabled/Enabled Setting Group 2: Disabled/Enabled Setting Group 3: Disabled/Enabled Setting Group 4: Disabled/Enabled System Config: Invisible/Visible Overcurrent: Disabled/Enabled Negative Sequence O/C: Disabled/Enabled Broken Conductor: Disabled/Enabled Earth Fault 1: Disabled/Enabled Earth Fault 2: Disabled/Enabled 1 Disabled/Enabled SEF/REF Prot: Residual O/V NVD: Disabled/Enabled Thermal Overload: Disabled/Enabled Neg. Sequence O/V: Disabled/Enabled Cold Load Pick-up: Disabled/Enabled Selective Logic: Disabled/Enabled Admit. Protection: Disabled/Enabled Power Protection: Disabled/Enabled Volt Protection: Disabled/Enabled Freq. Protection: Disabled/Enabled CB Fail: Disabled/Enabled Supervision: Disabled/Enabled Fault Locator: Disabled/Enabled 2 Disabled/Enabled System Checks : Disabled/Enabled Auto-Reclose3: Input Labels: Invisible/Visible Output Labels: Invisible/Visible Adv. Freq. Protn: Disabled/Enabled CT & VT Ratios: Invisible/Visible Record Control: Invisible/Visible Disturb Recorder: Invisible/Visible Measuret Setup: Invisible/Visible Comms Settings: Invisible/Visible Commission Tests: Invisible/Visible Setting Values: Primary/Secondary Control Inputs: Invisible/Visible Ctrl I/P Config: Invisible/Visible Ctrl I/P Labels: Invisible/Visible Direct Access: Disabled/Enabled InterMiCOM: Disabled/Enabled 4 Invisible/Visible Function Key : RP1 Read Only: Disabled/Enabled RP2 Read Only: Disabled/Enabled NIC Read Only: Disabled/Enabled LCD Contrast: (Factory pre-set)

Circuit Breaker Control (CB Control)


CB Control by: Disabled Local Remote Local+Remote Opto Opto+local Opto+Remote Opto+Rem+local Close Pulse Time: 0.1050.00s Trip Pulse Time: 0.105.00s Man Close t max: 0.019999.00s Man Close Delay: 0.01600.00s CB Healthy Time: 0.019999.00s Check Sync. Time: 0.019999.00s Reset Lockout by: User Interface/CB Close Man Close RstDly: 0.10600.00s CB Status Input: None 52A 52B 52A & 52B

Date and Time


IRIG-B Sync: Battery Alarm: LocalTime Enable: LocalTime Offset: DST Enable: DST Offset: DST Start: DST Start Day: DST Start Month: Mins: DST End: DST End Day: Disabled/Enabled Disabled/Enabled Disabled/Fixed/Flexible -720 min720min Disabled/Enabled 30min60min First/Second/Third/ Fourth/Last Sun/Mon/Tues/Wed/ Thurs/Fri/Sat Jan/Feb/Mar/Apr/May/ Jun/Jul/Aug/Sept/Oct/ Nov/Dec DST Start 0min1425min First/Second/Third/ Fourth/Last Sun/Mon/Tues/Wed/ Thurs/Fri/Sat

P14x Technical Data Sheet

20

P141/2/3/4/5 Software Version 44J

CT and VT Ratios
Main VT Primary: 100V...1MV Main VT Sec'y: 80...140V C/S VT Primary2: 100V...1MV C/S VT Secondary: 80...140V NVD VT Primary5: 100V...1MV NVD VT Secondary: 80...140V Phase CT Primary: 1A30kA Phase CT Sec'y: 1A/5A E/F CT Primary: 1A30kA E/F CT Sec'y: 1A/5A SEF CT Primary: 1A30kA SEF CT Sec'y: 1A/5A I Derived Phase5: IA IB IC None C/S Input2: A-N B-N C-N A-B B-C C-A Main VT Location2: Line/Bus

Input 1 Trigger: No Trigger/Trigger L/H/Trigger H/L (up to): Input 32 Trigger: No Trigger/Trigger L/H/ Trigger H/L

Measured Operating Data (Measure't. Setup)


Default Display: 3Ph + N Current 3Ph Voltage Power Date and Time Description Plant Reference Frequency Access Level Local Values: Primary/Secondary Remote Values: Primary/Secondary Measurement Ref: VA/VB/VC/IA/IB/IC Measurement Mode: 0/1/2/3 Fix Dem. Period: 199mins Roll Sub Period: 199mins Num. Sub Periods: 115 Distance Unit: Miles/Kilometers Fault Location: Distance Ohms % of Line Remote2 Values: Primary/Secondary

Sequence of Event Recorder (Record Control)


Alarm Event: Disabled/Enabled Relay O/P Event: Disabled/Enabled Opto Input Event: Disabled/Enabled General Event: Disabled/Enabled Fault Rec. Event: Disabled/Enabled Maint. Rec. Event: Disabled/Enabled Protection Event: Disabled/Enabled DDB 31 - 0: (up to): DDB 1279 - 1248: Binary function link strings, selecting which DDB signals will be stored as events, and which will be filtered out

Communications
RP1 Protocol: Courier IEC870-5-103 DNP 3.0 RP1 Address: (Courier or IEC870-5-103): 0255 RP1 Address: (DNP3.0): 065519 RP1 InactivTimer: 130mins RP1 Baud Rate: (IEC870-5-103): 9600/19200 bits/s RP1 Baud Rate: (DNP3.0): 1200 bits/s 2400 bits/s 4800 bits/s 9600 bits/s 19200 bits/s 38400 bits/s RP1 Parity: Odd/Even/None RP1 Meas Period: 160s RP1 PhysicalLink: Copper Fiber Optic (IEC870-5-103, DNP3.0, Courier, MODBUS) K-Bus (Courier only) RP1 Time Sync: Disabled/Enabled DNP Need Time: 130m DNP App Fragment: 1002048 21
P141/2/3/4/5 Software Version 44J

Oscillography (Disturb. Recorder)


Duration: 0.1010.50s Trigger Position: 0.0100.0% Trigger Mode: Single/Extended Analog Channel 1: (up to): Analog Channel 8: Disturbance channels selected from: VA/VB/VC/Vchecksync./IA/IB/IC/IN/IN Sensitive Digital Input 1: (up to): Digital Input 32: Selected binary channel assignment from any DDB status point within the relay (opto input, output contact, alarms, starts, trips, controls, logic).

P14x Technical Data Sheet

DNP App Timeout: 1120 DNP SBO Timeout: 110 DNP Link Timeout: 0120 RP1 CS103 Blocking: Disabled Monitor Blocking Command Blocking RP1 Port Config. (Courier): K Bus EIA(RS)485 RP1 Comms. Mode: IEC60870 FT1.2 Frame 10-Bit No Parity

No. CB Ops Maint: 110000 No. CB Ops Lock: Alarm Disabled/Enabled No. CB Ops Lock: 110000 CB Time Maint: Alarm Disabled/Enabled CB Time Maint: 0.0050.500s CB Time Lockout: Alarm Disabled/Enabled CB Time Lockout: 0.0050.500s Fault Freq. Lock: Alarm Disabled/Enabled Fault Freq. Count: 19999 Fault Freq. Time: 09999s

Optional Additional Second Rear Communication (Rear Port2 (RP2))


RP2 Protocol: Courier (fixed) RP2 Port Config: Courier over EIA(RS)232 Courier over EIA(RS)485 K-Bus RP2 Comms. Mode: IEC60870 FT1.2 Frame 10-Bit NoParity RP2 Address: 0255 RP2 InactivTimer: 130mins RP2 Baud Rate: 9600 bits/s 19200 bits/s 38400 bits/s

Optocoupled Binary Inputs (Opto Config.)


Global threshold: 24 - 27V 30 - 34V 48 - 54V 110 - 125V 220 - 250V Custom Opto Input 1: (up to): Opto Input #. (# = max. opto no. fitted): Custom options allow independent thresholds to be set per opto, from the same range as above. Filter Control: Binary function link string, selecting which optos will have an extra 1/2 cycle noise filter, and which will not. Characteristics: Standard 60% - 80% 50% - 70% Time stamping accuracy: + 1 msec

Optional Ethernet Port


NIC Tunl Timeout: 1...30mins NIC Link Report: Alarm/Event/None NIC Link Timeout: 0.1...60s

Commission Tests
Monitor Bit 1: (up to): Monitor Bit 8: Binary function link strings, selecting which DDB signals have their status visible in the Commissioning menu, for test purposes Test Mode: Disabled Test Mode Blocked Contacts Test Pattern: Configuration of which output contacts are to be energized when the contact test is applied. Static Test Mode: Disabled/Enabled

Control Inputs into PSL (Ctrl. I/P Config.)


Hotkey Enabled: Binary function link string, selecting which of the control inputs will be driven from Hotkeys. Control Input 1: Latched/Pulsed (up to): Control Input 32: Latched/Pulsed Ctrl Command 1: (up to): Ctrl Command 32: ON/OFF SET/RESET IN/OUT ENABLED/DISABLED

Circuit Breaker Condition Monitoring (CB Monitor Setup)


Broken I^: 1.02.0 I^ Maintenance: Alarm Disabled/Enabled I^ Maintenance: 125000 I^ Lockout: Alarm Disabled/Enabled I^ Lockout: 125000 No. CB Ops Maint: Alarm Disabled/Enabled
P14x Technical Data Sheet

EIA(RS)232 Teleprotection (InterMiCOM Comms.)


Source Address: 110 Received Address: 110 Data Rate: 600 Baud 1200 Baud 2400 Baud 22
P141/2/3/4/5 Software Version 44J

4800 Baud 9600 Baud 19200 Baud Loopback Mode: Disabled/Internal/External Test Pattern: Configuration of which InterMiCOM signals are to be energized when the loopback test is applied.

Control Input User Labels (Ctrl. I/P Labels)


Control Input 1: (up to): Control Input 32: User defined text string to describe the function of the particular control input

Settings in Multiple Groups InterMiCOM Conf.


IM Msg Alarm Lvl: 0100.0% IM1 Cmd Type: Disabled/Direct/Blocking (up to): IM4 Cmd Type: Disabled/Direct/Blocking IM5 Cmd Type: Disabled/Permissive/Direct (up to): IM8 Cmd Type: Disabled/Permissive/Direct IM1 FallBackMode: Default/Latched (up to): IM8 FallBackMode: Default/Latched IM1 DefaultValue: 0/1 (up to): IM8 DefaultValue: 0/1 IM1 FrameSyncTim: 10ms1.50s (up to): IM8 FrameSyncTim: 10ms1.50s Note: All settings here onwards apply for setting groups # = 1 to 4.

Function Keys4
Fn. Key Status 1: (up to): Fn. Key Status 10 Disable Lock Unlock/Enable Fn. Key 1 Mode: Toggled/Normal (up to): Fn. Key 10 Mode: Toggled/Normal Fn. Key 1 Label: (up to): Fn. Key 10 Label: User defined text string to describe the function of the particular function key

IED CONFIGURATOR
Switch Conf. Bank: No Action/Switch Banks

IEC61850 GOOSE
GoEna: Disabled/Enabled Test Mode: Disabled/Pass Through/Forced VOP Test Pattern: 0x00000000... 0xFFFFFFFF Ignore Test Flag: No/Yes

P14x Technical Data Sheet

23

P141/2/3/4/5 Software Version 44J

Protection Functions
System Config.
Phase Sequence: Standard ABC Reverse ACB 2NDHARM BLOCKING: Disabled Enabled 2ndHarm Thresh: 570 I>lift 2H: 432

Phase Overcurrent (Overcurrent)


I>1 Function: Disabled DT IEC S Inverse IEC V Inverse IEC E Inverse UK LT Inverse UK Rectifier RI IEEE M Inverse IEEE V Inverse IEEE E Inverse US Inverse US ST Inverse I>1 Direction: Non-Directional Directional Fwd Directional Rev I>1 Current Set: 0.084.00 In I>1 Time Delay: 0.00100.00s I>1 TMS: 0.0251.200 I>1 Time Dial: 0.01100.00 I>1 K (RI): 0.1010.00 I>1 DT Adder: 0.00100.00 I>1 Reset Char.: DT/Inverse I>1 tRESET: 0.00100.00s I>2 Status (up to): I>2 tRESET All settings and options chosen from the same ranges as per the first stage overcurrent, I>1. I>3 Status: Disabled Enabled I>3 Direction: Non-Directional Directional Fwd Directional Rev I>3 Current Set: 0.0832.00 In I>3 Time Delay: 0.00100.00s I>4 Status (up to): I>4 Time Delay All settings and options chosen from the same ranges as per the third stage overcurrent, I>3.
P14x Technical Data Sheet

I> Char Angle: -9595 I>5 Status (up to): I>5 tRESET All settings and options chosen from the same ranges as per the first stage overcurrent, I>1. I>6 Status (up to): I>6 Time Delay All settings and options chosen from the same ranges as per the third stage overcurrent, I>3. I> Blocking: Binary function link string, selecting which overcurrent elements (stages 1 to 4) will be blocked if VTS detection of fuse failure occurs. Binary function link string, selecting which overcurrent elements (stages 1 to 4) will be nd blocked if 2 Harmonic Block is enabled with an option of choosing 1PH block.

Voltage Controlled Overcurrent


VCO Status: Disabled I>1 I>2 Both I>1 & I>2 VCO V<Setting: 20120V (100/120V) 80480V (380/440V) VCO k Setting: 0.251.00

Negative Sequence Overcurrent


I2>1 Function: Disabled DT IEC S Inverse IEC V Inverse IEC E Inverse UK LT Inverse IEEE M Inverse IEEE V Inverse IEEE E Inverse US Inverse US ST Inverse I2>1 Direction: Non-Directional Directional Fwd Directional Rev I2>1 Current Set: 0.084.00 In I2>1 Time Delay: 0.00100.00s I2>1 TMS: 0.0251.200 I2>1 Time Dial: 0.01100.00 I2>1 DT Adder: 0.00100.00 I2>1 Reset Char.: DT/Inverse I2>1 tRESET: 0.00100.00s I2>2 Status

24

P141/2/3/4/5 Software Version 44J

(up to): I2>2 tRESET All settings and options chosen from the same ranges as per the first stage overcurrent, I2>1. I2>3 Status: Disabled Enabled I2>3 Direction: Non-Directional Directional Fwd Directional Rev I2>3 Current Set: 0.0832.00 In I2>3 Time Delay: 0.00100.00s I2>4 Status (up to): I2>4 Time Delay All settings and options chosen from the same ranges as per the third stage overcurrent, I2>3. I2> VTS Blocking: Binary function link string, selecting which Neg. Seq. O/C elements (stages 1 to 4) will be blocked if VTS detection of fuse failure occurs. Binary function link string, selecting which Neg. Seq. O/C elements (stages 1 to 4) will nd be blocked if 2 Harmonic Block is enabled. I2> Char Angle: -9595 I2> V2pol Set: 0.525.0 (100 - 110V): 2100 (380 - 480V):

IN1>1 Current Set: 0.084.00 In IN1>1 IDG Is: 1.04.0 In IN1>1 Time Delay: 0.00200.00s IN1>1 TMS: 0.0251.200 IN1>1 Time Dial: 0.01100.00 IN1>1 K(RI): 0.10..10.00 IN1>1 IDG Time: 1.00..2.00 IN1>1 DT Adder: 0.00100.00 IN1>1 Reset Char.: DT/Inverse IN1>1 tRESET: 0.00100.00s IN1>2 Status (up to): IN1>2 tRESET All settings and options chosen from the same ranges as per the first stage ground overcurrent, IN>1. IN1>3 Status: Disabled Enabled IN1>3 Directional: Non-Directional Directional Fwd Directional Rev IN1>3 Current Set: 0.0832.00 In IN1>3 Time Delay: 0.00200.00s IN1>4 Status (up to): IN1>4 Time Delay All settings and options chosen from the same ranges as per the third stage ground overcurrent, IN>3. IN1> Blocking: Binary function link string, selecting which ground overcurrent elements (stages 1 to 4) will be blocked if VTS detection of fuse failure occurs. Binary function link string, selecting which ground overcurrent elements (stages 1 to 4) nd will be blocked if 2 Harmonic Block is enabled. IN1> Char Angle: -9595 IN1> Polarization: Zero Sequence Neg. Sequence IN1> VNpol Set: 0.580.0V (100 - 110V) 2320V (380 - 480V) IN1> V2pol Set: 0.525.0V (100 - 110V) 2100V (380 - 480V) IN1> I2pol Set: 0.081.00 In

Broken Conductor
Broken Conductor: Disabled/Enabled I2/I1 Setting: 0.201.00 I2/I1 Time Delay: 0.0100.0s

Ground Overcurrent (Earth Fault 1 & 2)


IN1>1 Function Disabled DT IEC S Inverse IEC V Inverse IEC E Inverse UK LT Inverse RI IEEE M Inverse IEEE V Inverse IEEE E Inverse US Inverse US ST Inverse IDG IN1>1 Directional Non-Directional Directional Fwd Directional Rev

Sensitive Earth Fault Protection/ Restricted Earth Fault Protection


SEF/REF Options: SEF SEF cos (PHI) SEF sin (PHI) Wattmetric 25
P141/2/3/4/5 Software Version 44J

P14x Technical Data Sheet

Hi Z REF Lo Z REF Lo Z REF + SEF Lo Z REF + Wattmetric ISEF>1 Function: Disabled DT IEC S Inverse IEC V Inverse IEC E Inverse UK LT Inverse RI IEEE M Inverse IEEE V Inverse: IEEE E Inverse US Inverse US ST Inverse IDG ISEF>1 Directional: Non-Directional Directional Fwd Directional Rev. ISEF>1 Current Set: 0.0050.01 In ISEF>1 IDG Is: 1.04.0 In ISEF>1 Time Delay: 0.00200.00s ISEF>1 TMS: 0.0251.200 ISEF>1 Time Dial: 0.5100.0 IN1>1 K(RI): 0.10..10.00 ISEF>1 IDG Time: 1.00..2.00 ISEF>1 DT Adder: 0.00100.00 ISEF>1 Reset Char: DT/Inverse ISEF>1 tRESET: 0.00100.00s ISEF>2 Status (up to): ISEF>2 tRESET All settings and options chosen from the same ranges as per the first stage ground overcurrent, IN>1. ISEF>3 Status: Disabled Enabled ISEF>3 Directional: Non-Directional Directional Fwd Directional Rev ISEF>3 Current Set: 0.005.2.000 In ISEF>3 Time Delay: 0.00200.00s ISEF>4 Status (up to): ISEF>4 Time Delay All settings and options chosen from the same ranges as per the third stage ground overcurrent, IN>3. ISEF> Blocking: Binary function link string, selecting which ground overcurrent elements (stages 1 to 4) will be blocked if VTS detection of fuse failure occurs. Binary function link string, selecting which ground overcurrent elements (stages 1 to 4) nd will be blocked if 2 Harmonic Block is enabled.
P14x Technical Data Sheet

ISEF> Char. Angle: -9595 ISEF> VNpol Set: 0.580.0V (100 - 110V) 2320V (380 - 480V) WATTMETRIC SEF: PN> Setting: 020W (1A, 100/120V) PN> Setting: 0100W (5A, 100/120V) PN> Setting: 0 80W (1A, 380/440V) PN> Setting: 0400W (5A, 380/440V) RESTRICTED EARTH-FAULT (Low Impedance) IREF > K1: 0 20% IREF > K2: 0 150% IREF > Is1: 0.081.00 In IREF > Is2: 0.11.50 In (High Impedance) IREF > K1: 0.051.00 In

Neutral Voltage Displacement (Residual O/V NVD)


VN>1 Function: Disabled DT IDMT VN>1 Voltage Set: 150V VN>1 Time Delay: 0.00100.00s VN>1 TMS: 0.5100.0 VN>1 tReset: 0.00100.00s VN>2 Status: Disabled/Enabled VN>2 Voltage Set: 180V (100/110V) 4320V (380/440V) VN>2 Time Delay: 0.00100.00s

Thermal Overload
Characteristic: Disabled Single Dual Thermal Trip: 0.084.00 In Thermal Alarm: 50100% Time Constant 1: 1200mins Time Constant 2: 1200mins

Negative Sequence Overvoltage Protection


V2> Status: Disabled/Enabled V2> Voltage Set: 1V110V (100/120V) 4V - 440V (380/440V) V2> Time Delay: 0.00100.00s

Cold Load Pick-up Setting


tcold Time Delay: 014 400s tclp Time Delay: 014 400s Overcurrent I>1 Status: Block/Enabled I>1 Current Set: 0.084.00 In 26
P141/2/3/4/5 Software Version 44J

I>1 Time delay: 0.00100.00s I>1 TMS: 0.025.2.000 I>1 Time Dial: 0.515.0 I>2 Status (up to): I>2 Time Dial All settings and options chosen from the same ranges as per the 1st stage. I>3 Status: Block/Enabled I>3 Current Set: 0.0832.00 In 3 Time delay: 0.00100.00s I>4 Status (up to): I>4 Time Delay All settings and options chosen from the same ranges as per the 1st stage. E/F1 IN1>1 Status: Block/Enabled IN1>1 Current Set: 0.084.00 In IN1>1 IDG Is: 1.04.0 In IN1>1 Time Delay: 0.00200.00s IN1>1 TMS: 0.025.2.000 IN1>1 Time Dial: 0.515.0 IN1>1 K(RI): 0.10..10.00 IN1>2 Status (up to): IN2> 1 K(RI) All settings and options chosen from the same ranges as per the E/F1 stage. I>5 Status (up to): I>5 Time Dial All settings and options chosen from the same ranges as per the 1st stage. I>6 Status (up to): I>6 Time Delay All settings and options chosen from the same ranges as per the 3rd stage.

Neutral Admittance Protection


VN Threshold: 140V (100/120V) 4160V (380/440V) CT Input Type: SEF CT/E/F CT Correction angle: 3030 Overadmittance YN Status: Disabled/Enabled YN> Set (SEF): 0.110mS (100/110V) 0.0252.5mS (380/440V) YN> Set (EF): 1100mS (100/110V) 0.2525mS (380/440V) YN> Time Delay: 0.05s100.00s YN> tRESET: 0.00100.00s Over Conductance GN Status: Disabled/Enabled GN>Direction Non-Directional Directional Fwd Directional Rev. GN> Set (SEF): 0.15mS (100/110V) 0.251.25mS (380/440V) GN> Set (E/F): 150mS (100/110V) 0.2512.5mS (380/440V) GN> Time Delay: 0.05s100s GN>tRESET: 0s100s Over Susceptance BN Status: Disabled/Enabled GN>Direction Non-Directional Directional Fwd Directional Rev. BN> Set (SEF) 0.15mS (100/110V) 0.0251.25mS (380/440V)) BN> Set (E/F): 150mS (100/110V) 0.2512.5mS (380/440V) BN> Time Delay: 0.05100s BN> tRESET: 0s100s

Selective Overcurrent Logic


Overcurrent I>3 Time Delay: 0.00100.00s I>4 Time Delay: 0.00100.00s Earth Fault1 IN1>3 Time Delay: 0.00200.00s IN1>4 Time Delay: 0.00200.00s Earth Fault2 IN2>3 Time Delay: 0.00200.00s IN2>4 Time Delay: 0.00200.00s Sensitive E/F ISEF>3 Time Delay: 0.00200.00s ISEF>4 Time Delay: 0.00200.00s Overcurrent I>6 Time Delay: 0.00100.00s

Undervoltage Protection
V< Measur't. Mode: Phase-Phase Phase-Neutral V< Operate Mode: Any Phase Three Phase V<1 Function: Disabled DT IDMT V<1 Voltage Set: 10120V (100/110V) 40480V (380/440V) V<1 Time Delay: 0.00100.00s V<1 TMS: 0.5100.0 27
P141/2/3/4/5 Software Version 44J

P14x Technical Data Sheet

V<1 Poledead Inh: Disabled/Enabled V<2 Status: Disabled/Enabled V<2 Voltage Set: 10120V (100/110V) 40480V (380/440V) V<2 Time Delay: 0.00100.00s V<2 Poledead Inh: Disabled/Enabled

Under-Frequency Protection
F<1 Status: Disabled/Enabled F<1 Setting: 45.0065.00Hz F<1 Time Delay: 0.00100.00s F<2 Status (up to): F<4 Time Delay All settings and options chosen from the same ranges as per the 1st stage. F> Blocking: Binary function link string, selecting which frequency elements (stages 1 to 4) will be blocked by the pole-dead logic.

Overvoltage Protection
V> Measur't. Mode: Phase-Phase Phase-Neutral V> Operate Mode: Any Phase Three Phase V>1 Function: Disabled DT IDMT V>1 Voltage Set: 60185V (100/110V) 240740V (380/440V) V>1 Time Delay: 0.00100.00s V>1 TMS: 0.5100.0 V>2 Status: Disabled/Enabled V>2 Voltage Set: 60185V (100/110V) 240740V (380/440V) V>2 Time Delay: 0.00100.00s

Over-Frequency Protection
F>1 Status: Disabled/Enabled F>1 Setting: 45.0065.00Hz F>1 Time Delay: 0.00100.00s F<2 Status (up to): F<2 Time Delay All settings and options chosen from the same ranges as per the 1st stage.

Advanced Over/Under Frequency Protection (f+t [81U/81O])


Stage 1 f+t Status: Disabled Enabled 1 (f+t) f: 40.1069.90Hz 1 (f+t) t: 0.00100.00s Stage 2 f+t Status (up to): 9 (f+t)t All settings and options chosen from the same ranges as per the first stage over/underfrequency, Stage 1 f+t.

dv/dt Protection
dv/dt Meas. Mode: Phase-Phase Phase-Neutral dv/dt1 Function: Disabled Negative Positive Both dv/dt1 Oper Mode: Any Phase Three Phase dv/dt1 AvgCycles: 550 dv/dt1 Threshold: 0.5200 dv/dt1 TimeDelay: 0100s dv/dt1 tRESET: 0100s dv/dt2 Function: Disabled Negative Positive Both dv/dt2 Oper Mode: Any Phase Three Phase dv/dt2 AvgCycles: 550 dv/dt2 Threshold: 0.5200 dv/dt2 TimeDelay: 0100s dv/dt2 tRESET: 0100s

Advanced Frequency Supervised Rate of Change of Frequency Protection (f+df/dt [81RF]


Stage 1 f+df/dt Status: Disabled Enabled 1 (f+df/dt) f: 40.1069.90Hz 1 (f+df/dt) df/dt: 0.0110.0Hz/s Stage 2 f+df/dt Status (up to): 9 (f+df/dt) df/dt All settings and options chosen from the same ranges as per the first stage frequency supervized rate of change of frequency, Stage 1 f+df/dt.

P14x Technical Data Sheet

28

P141/2/3/4/5 Software Version 44J

Advanced Independent Rate of Change of Frequency Protection (df/dt+t [81R])


Stage 1 df/dt+t Status: Disabled Negative Positive 1 (df/dt+t) df/dt: 0.0110.00Hz/s 1 (df/dt+t) t: 0.00100.00 s Stage 2 df/dt+t Status (up to): 9 (df/dt+t) t All settings and options chosen from the same ranges as per the first stage independent rate of change of frequency, Stage 1 df/dt+t.

Undercurrent
I< Current Set: 0.023.20 In IN< Current Set: 0.023.20 In ISEF< Current Set: 0.0010.800 In BLOCKED O/C Remove I> Start: Disabled/Enabled Remove IN> Start: Disabled/Enabled

Fuse Failure (VT Supervision)


VTS Status: Blocking/Indication VTS Reset Mode: Manual/Auto VTS Time Delay: 1.010.0s VTS I> Inhibit: 0.0832.00 In VTS I2> Inhibit: 0.050.50 In

Advanced Average Rate of Change of Frequency Protection (f+Df/Dt [81RAV])


Stage 1 f+Df/Dt Status: Disabled Enabled 1 (f+Df/Dt) f: 40.1069.90Hz 1 (f+Df/Dt) Df: 0.210.0Hz 1 (f+Df/Dt) Dt: 0.022.00 s Stage 2 f+Df/Dt Status (up to): 9 (f+Df/Dt) Dt All settings and options chosen from the same ranges as per the first stage average rate of change of frequency, Stage 1 f+Df/Dt.

CT Supervision
CTS Status: Disabled/Enabled CTS VN< Inhibit: 0.522.0V (100/110V) 288V (380/440V) CTS IN> Set: 0.084.00 In CTS Time Delay: 010s VTS PickupThresh: 20120V

Fault Locator
Line Length (km): 0.0011000.000km Line Length (mi): 0.20625.00mi Line Impedance: 0.10250.00 Line Angle: 2085 KZN Residual: 0.007.00 KZN Res. Angle: -9090

Advanced Load Restoration


Restore1 Status: Disabled Enabled Restore1 Freq.: 40.1069.90Hz Restore1 Time: 07200s Restore2 Status (up to): Restore9 Time All settings and options chosen from the same ranges as per the first stage load restoration, Restore1.

Bus-Line Synchronizm and Voltage Checks (System Checks)


VOLTAGE MONITORS Live Voltage: 1.0132.0V (100/110V) 22528V (380/440V) Dead Voltage: 1.0132.0V (100/110V) 22528V (380/440V)

Synchrocheck (Check Sync.)


CS1 Status: Disabled/Enabled CS1 Phase Angle: 590 CS1 Slip Control: None Timer Frequency Both CS1 Slip Freq.: 0.011.00Hz CS1 Slip Timer: 0.099.0s CS2 Status (up to): CS2 Slip Timer All settings and options chosen from the same ranges as per the first stage CS1 element. 29
P141/2/3/4/5 Software Version 44J

Circuit Breaker Fail


CB Fail 1 Status: Disabled/Enabled CB Fail 1 Timer: 0.0010.00s CB Fail 2 Status: Disabled/Enabled CB Fail 2 Timer: 0.0010.00s Volt Prot. Reset: I< Only CB Open & I< Prot. Reset & I< Ext Prot. Reset: I< Only CB Open & I< Prot. Reset & I<
P14x Technical Data Sheet

CS Undervoltage: 10.0132.0V (100/110V) 40528V (380/440V) CS Overvoltage: 40.0185.0V (100/110V) 160740V (380/440V) CS Diff Voltage: 1.0132.0V (100/110V) 4528V (380/440V) CS Voltage Block: None Undervoltage Overvoltage Differential UV & OV UV & DiffV OV & DiffV UV, OV & DiffV

System Split
SS Status: Disabled/Enabled SS Phase Angle: 90175 SS Under V Block: Disabled/Enabled SS Undervoltage: 10.0132.0V (100/110V) 40528V (380/440V) SS Timer: 0.099.0s CB Close Time: 0.0000.500s

Auto-reclose
AR Mode Select: Command Mode Opto Set Mode User Set Mode Pulse Set Mode Number of Shots: 14 Number of SEF Shots: 04 Sequence Co-ord.: Disabled/Enabled CS AR Immediate: Disabled/Enabled Dead Time 1: 0.01300.00s Dead Time 2: 0.01300.00s Dead Time 3: 0.019999.00s Dead Time 4: 0.019999.00s CB Healthy Time: 0.01s9999.00s Start Dead on: Protection Resets/CB Trips Reclaim Extend: No Operation/On Prot. Start Reclaim Time 1: 1.00600.00s Reclaim Time 2: 1.00600.00s Reclaim Time 3: 1.00600.00s Reclaim Time 4: 1.00600.00s AR Inhibit Time: 0.01600.00s AR Lockout: No Block/Block Inst. Prot. EFF Maint. Lock: No Block/Block Inst. Prot. AR Deselected: No Block/Block Inst. Prot. Manual close: No Block/Block Inst. Prot.

Trip 1 Main: No Block/Block Inst. Prot. Trip 2 Main: No Block/Block Inst. Prot. Trip 3 Main: No Block/Block Inst. Prot. Trip 4 Main: No Block/Block Inst. Prot. Trip 5 Main: No Block/Block Inst. Prot. Trip 1 SEF: No Block/Block Inst. Prot. Trip 2 SEF: No Block/Block Inst. Prot. Trip 3 SEF: No Block/Block Inst. Prot. Trip 4 SEF: No Block/Block Inst. Prot. Trip 5 SEF: No Block/Block Inst. Prot. Man. Close on Flt.: No Lockout/Lockout Trip AR Inactive: No Lockout/Lockout Reset Lockout by: User Interface/Select Non-Auto AR on Man. Close: Enabled/Inhibited Sys. Check Time: 0.019999.00s AR Skip Shot 1: Enabled/disabled AR INITIATION I>1, I>2: No Action/Initiate Main AR I>3 and I>4: No Action/Initiate Main AR/Block AR IN1>1 and IN1>2: No Action/Main AR IN1>3 and IN1>4: No Action/Initiate Main AR/Block AR IN2>1, IN2>2: No Action/Initiate Main AR IN2>3 and IN2>4: No Action/Initiate Main AR/Block AR ISEF>1, ISEF>2, ISEF>3 and ISEF>4: No Action/Initiate Main AR/Initiate SEF AR/ Block AR YN/GN/ BN>: No Action/Initiate Main AR Ext. Prot.: No Action/Initiate Main AR SYSTEM CHECKS AR with ChkSync.: Disabled/Enabled AR with SysSync.: Disabled/ Enabled Live/Dead Ccts: Disabled/Enabled No System Checks: Enabled/Disabled SysChk on Shot 1: Disabled/ Enabled I>5: No Action/Initiate Main AR I>6: No Action/Initiate Main AR/Block AR

Opto Input Labels


Opto Input 1: (up to): Opto Input 24: User defined text string to describe the function of the particular opto input.

Output Labels
Relay 1: (up to): Relay 32: User defined text string to describe the function of the particular relay output contact.

P14x Technical Data Sheet

30

P141/2/3/4/5 Software Version 44J

Measurements List
Measurements 1
I Magnitude I Phase Angle Per phase ( = A, B, C) current measurements IN Measured Mag. IN Measured Ang. IN Derived Mag. IN Derived Angle ISEF Magnitude ISEF Angle I1 Magnitude I2 Magnitude I0 Magnitude I RMS Per phase ( = A, B, C) RMS current measurements V- Magnitude V- Phase Angle V Magnitude V Phase Angle All phase-phase and phase-neutral voltages ( = A, B. C) VN Derived Mag. VN Derived Ang. V1 Magnitude. V2 Magnitude V0 Magnitude V RMS All phase-neutral voltages ( = A, B, C) Frequency C/S Voltage Mag. C/S Voltage Ang. C/S Bus-line Ang. Slip Frequency IM Magnitude IM Phase Angle I1 Magnitude I1 Phase Angle I2 Magnitude I2 Phase Angle I0 Magnitude I0 Phase Angle V1 Magnitude V1 Phase Angle V2 Magnitude V2 Phase Angle V0 Magnitude V0 Phase Angle

3 Phase Watts 3 Phase VArs 3 Phase VA Zero Seq. Power 3Ph Power Factor Ph Power Factor Independent power factor measurements for all three phases ( = A, B, C). 3Ph WHours Fwd 3Ph WHours Rev. 3Ph VArHours Fwd 3Ph VArHours Rev. 3Ph W Fix Demand 3Ph VArs Fix Dem. I Fixed Demand Maximum demand currents measured on a per phase basis ( = A, B, C). 3Ph W Roll Dem. 3Ph VArs Roll Dem. I Roll Demand Maximum demand currents measured on a per phase basis ( = A, B, C). 3Ph W Peak Dem. 3Ph VAr Peak Dem. I Peak Demand Maximum demand currents measured on a per phase basis ( = A, B, C). Reset Demand: Yes/No

Measurements 3
Highest Phase I Thermal State Reset Thermal IREF Diff. IREF Bias Admittance Conductance Susceptance Admittance Conductance Susceptance I2/I1 Ratio SEF Power IA 2nd Harmonic IB 2nd Harmonic IC 2nd Harmonic

Stage Statistics (Advanced)


StgX f+t Sta StgX f+t Trip StgX f+df/dt Trp StgX df/dt+t Sta StgX df/dt+t Trp StgX f+Df/Dt Sta StgX f+Df/Dt Trp StgX Revn Date (X = 1, 2, 3, 4, 5, 6, 7, 8, 9)

Measurements 2
Phase Watts Phase VArs Phase VA All phase segregated power measurements, real, reactive and apparent ( = A, B, C)
P14x Technical Data Sheet

31

P141/2/3/4/5 Software Version 44J

Circuit Breaker Monitoring Statistics


CB Operations CB Operations Circuit breaker operation counters on a per phase basis ( = A, B, C). Total I Broken Cumulative breaker interruption duty on a per phase basis ( = A, B, C). CB Operate Time CB CONTROL Total Re-closures

Fault Record Proforma


The following data is recorded for any relevant elements that operated during a fault, and can be viewed in each fault record. Time & Date Event Text Event Value Select Fault: [0...n] Started Phase: A/B/C Tripped Phase: A/B/C Overcurrent Start I> 123456 Trip I> 123456 Neg. Seq. O/C Start I2> 1234 Trip I2> 1234 Broken ConductorTrip Earth Fault 1 Start IN1> 1234 Trip IN1> 1234 Earth Fault 2 Start IN2> 1234 Trip IN2> 1234 Sensitive E/F Start ISEF> 1234 Trip ISEF> 1234 Restricted E/F Trip IREF> Residual O/V NVD Start VN> 1 2 Trip VN> 1 2 Thermal Overload: Alarm/Trip Neg. Seq. O/V V2> Start Trip U/Voltage Start V< 1 2 AB BC CA U/Voltage Trip V< 1 2 AB BC CA O/Voltage Start V> 1 2 AB BC CA O/Voltage Trip V> 1 2 AB BC CA Underfrequency Start F< 1234 Trip F< 1234 Overfrequency Start F> 1 2 Trip F> 1 2

Overadmittance YN> Start Trip Overconductance GN> Start Trip Oversusceptance BN> Start Trip Breaker Fail: CB Fail 1 2 Supervision VTS/CTS/VCO/CLP A/R State: Trip 1/2/3/4/5 Advanced Freq. Protection Start >123456789 Advanced Freq. Protection Trip >123456789 Adv. F+df/dt Protection Trip >123456789 Adv. df/dt Protection Start >123456789 Adv. df/dt Protection Trip >123456789 Adv. DelF/DelT Protection Start >123456789 Adv. DelF/DelT Protection Trip >123456789 Faulted Phase: A/B/C Start Elements: Trip Elements: Binary data strings for fast polling of which protection elements started or tripped for the fault recorded. Fault Alarms: Binary data strings for fast polling of alarms for the fault recorded. Fault Time: Active Group: 1/2/3/4 System Frequency: Hz Fault Duration: s CB Operate Time: s Relay Trip Time: s Fault Location: km/miles//% The current magnitudes and phase angles stored before the fault inception. I V: Per phase record of the current and voltage magnitudes during the fault. IN Measured IN Derived IN Sensitive IREF Diff. IREF Bias VAN VBN VCN VN Derived Admittance Conductance Susceptance

P14x Technical Data Sheet

32

P141/2/3/4/5 Software Version 44J

P14x Case Dimensions

Figure 1: P141/P142 Case dimensions

P14x Technical Data Sheet

33

P141/2/3/4/5 Software Version 44J

P1616ENi

Figure 2:

P143/P145 Case dimensions

Figure 3:

P143 with 32I + 32O Case dimensions

P14x Technical Data Sheet

34

P141/2/3/4/5 Software Version 44J

P14x 2nd Rear Communication Board Connection Diagram

P1727ENb

Figure 4:

P14x second rear port connection 35


P141/2/3/4/5 Software Version 44J

P14x Technical Data Sheet

External Connection Diagrams

P2140ena

Figure 5:

P141 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault (8 I/P & 7 O/P) 36
P141/2/3/4/5 Software Version 44J

P14x Technical Data Sheet

P2141ena

Figure 6:

P141 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with High Impedance Restricted Earth Fault (8 I/P & 7 O/P) P14x Technical Data Sheet 37 P141/2/3/4/5 Software Version 44J

P2142ena

Figure 7:

P141 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Low Impedance Restricted Earth Fault (8 I/P & 7 O/P) P14x Technical Data Sheet 38 P141/2/3/4/5 Software Version 44J

P2143ena

Figure 8:

P141 Feeder Management Relay - Directional and Directional Earth Fault with VEE Connected VT (8 I/P & 7 O/P) P14x Technical Data Sheet 39 P141/2/3/4/5 Software Version 44J

P4609ENa

Figure 9:

P141 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault (8 I/P & 8 O/P)

P14x Technical Data Sheet

40

P141/2/3/4/5 Software Version 44J

P2144ena

Figure 10: P142 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose (8 I/P & 7 O/P) P14x Technical Data Sheet 41 P141/2/3/4/5 Software Version 44J

Figure 11: P142 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose (8 I/P & 11 O/P with 4 High Break Contacts)
P14x Technical Data Sheet

42

P141/2/3/4/5 Software Version 44J

P2145ena

Figure 12: P142 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose (12 I/P & 11 O/P) P14x Technical Data Sheet 43 P141/2/3/4/5 Software Version 44J

P2146ena

Figure 13: P142 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose (16 I/P & 7 O/P) P14x Technical Data Sheet 44 P141/2/3/4/5 Software Version 44J

P2147ena

Figure 14: P142 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose (8 I/P & 15 O/P) P14x Technical Data Sheet 45 P141/2/3/4/5 Software Version 44J

P2148ena

Figure 15: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 14 O/P) P14x Technical Data Sheet 46 P141/2/3/4/5 Software Version 44J

P2270ENa

Figure 16: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 18 O/P with 4 High Break Outputs) P14x Technical Data Sheet 47 P141/2/3/4/5 Software Version 44J

P2151ena

Figure 17: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 22 O/P) P14x Technical Data Sheet 48 P141/2/3/4/5 Software Version 44J

P2271ENa

Figure 18: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 22 O/P with 8 High Break Contacts) P14x Technical Data Sheet 49 P141/2/3/4/5 Software Version 44J

P2272ENa

Figure 19: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 26 O/P with 4 High Break Contacts) P14x Technical Data Sheet 50 P141/2/3/4/5 Software Version 44J

P2154ena

Figure 20: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 30 O/P) P14x Technical Data Sheet 51 P141/2/3/4/5 Software Version 44J

P2149ena

Figure 21: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (24 I/P & 14 O/P) P14x Technical Data Sheet 52 P141/2/3/4/5 Software Version 44J

P2273ENa

Figure 22: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (24 I/P & 22 O/P)

P14x Technical Data Sheet

53

P141/2/3/4/5 Software Version 44J

Figure 23: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-Reclose and Check Synchronizing (32 I/P & 32 O/P)

P14x Technical Data Sheet

54

P141/2/3/4/5 Software Version 44J

P2153ena

Figure 24: P143 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (32 I/P & 14 O/P) P14x Technical Data Sheet 55 P141/2/3/4/5 Software Version 44J

Figure 25: P144 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose and Separate Residual Voltage Input (8 I/P & 7 O/P)
P14x Technical Data Sheet

56

P141/2/3/4/5 Software Version 44J

Figure 26: P144 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose and Separate Residual Voltage Input (8 I/P & 11 O/P with 4 High Break Contacts) P14x Technical Data Sheet 57 P141/2/3/4/5 Software Version 44J

Figure 27: P144 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose and Separate Residual Voltage Input (8 I/P & 15 O/P)
P14x Technical Data Sheet

58

P141/2/3/4/5 Software Version 44J

Figure 28: P144 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose and Separate Residual Voltage Input (12 I/P & 11 O/P)
P14x Technical Data Sheet

59

P141/2/3/4/5 Software Version 44J

Figure 29: P144 Feeder Management Relay - Directional Phase Overcurrent and Earth Fault with Auto-reclose and Separate Residual Voltage Input (16 I/P & 7 O/P)
P14x Technical Data Sheet

60

P141/2/3/4/5 Software Version 44J

DIRECTION OF FORWARD CURRENT FLOW P1 X X B A C B C C B PHASE ROTATION X A A

P2

P1 P2

S2

S1

S2

S1

MiCOM P145 (PART)


C1 N A 5A

MiCOM P145 (PART)


J11 F1 OPTO 9 F2 F3 OPTO 10 F4 F5 OPTO 11 F6 F7 F8 J13 J14 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 RELAY 6 H13 H14 H15 H16 J17 SEE DRAWING 10Px4001. EIA485/ KBUS PORT + J18 J16 SCN J1 H17 H18 F9 F10 F11 F12 AC OR DC RELAY 10 RELAY 8 RELAY 7 COMMS NOTE 5. J12 WATCHDOG CONTACT WATCHDOG CONTACT RELAY 1 RELAY 2

A C3 C4 B C6 C7 C C9 C10 5A D3 + + + + + + + OPTO 8 OPTO 7 OPTO 6 OPTO 5 OPTO 4 OPTO 3 OPTO 2 D4 C12 C13 D7 D8 C15 A C19 D11 D12 D13 B C20 D14 D15 D16 C C21 D18 D17 D10 1A D9 N SENSITIVE 5A D6 1A D5 NOTE 4. N D2 + 1A OPTO 1 D1 OPTO 12 5A 1A C24 V CHECK SYNC 5A C23 1A

B C

n a b c

NOTE 2.

a b c

RELAY 3 ANY TRIP NOTE 3. RELAY 4 RELAY 5

RELAY 9

*
x AUX SUPPLY
+ + J2 J7

F13 F14 F15 F16 F17 + 48V DC FIELD VOLTAGE OUT J8 J9 J10 F18 RELAY 12 RELAY 11

COMMON CONNECTION

N C22

NOTES 1.

CASE EARTH

(a)

C.T. SHORTING LINKS

2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY. 3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY. 4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU. 5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.

* POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY

(b)

Figure 30: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (12 I/P & 12 O/P) P14x Technical Data Sheet 61 P141/2/3/4/5 Software Version 44J

PIN TERMINAL (P.C.B. TYPE)

P1608ENa

DIRECTION OF FORWARD CURRENT FLOW A X X B A B C C C B PHASE ROTATION X A

P2

P1 P2

P1

S2

S1

S2

S1

MiCOM P145 (PART)


C1 N

MiCOM P145 (PART)


F1 J11 J12 J13 J14 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 F17 F18 H18 G1 G2
COMMS NOTE 5.

5A OPTO 9 F2 F3 OPTO 10 F4 F5 OPTO 11 F6 F7 OPTO 12 F8 F9

A
C2

A C3 C4 B
C5

B C

n
1A 5A C23
V CHECK SYNC

WATCHDOG CONTACT WATCHDOG CONTACT RELAY 1 RELAY 2 RELAY 3 ANY TRIP NOTE 3. RELAY 4 RELAY 5 RELAY 6 RELAY 7

NOTE 2.

a b c

n
C6 C7 C
C8

1A 5A OPTO 13 + + OPTO 15 F14 F15 OPTO 16 F16 OPTO 4 COMMON CONNECTION OPTO 3 + + + + + + COMMON CONNECTION AC OR DC OPTO 8 OPTO 7 OPTO 6 OPTO 5 OPTO 2 F13
NOTE 4.

C24

a b c
D1 D2 D3 D4 1A 5A D7 D8 C15
A

F10 F11

C9

1A OPTO 1 OPTO 14 F12 5A

C10 N
C11

D5 D6

N SENSITIVE

C12 C13

RELAY 8

1A D9 D10 D11 D12 D13

C19

RELAY 9 G3 G4 G5
J17 SEE DRAWING 10Px4001.

RELAY 10 G6 G7 G8
EIA485/ KBUS PORT + J18 J16 SCN

RELAY 11 RELAY 12 G9 G10 G11 G12 J1 RELAY 13 RELAY 14

C20 D14 D15 D16

C21 D18

D17

*
x AUX SUPPLY
+ + + 48V DC FIELD VOLTAGE OUT J2 J7 J8 J9 J10

G13 G14 G15 G16 G17 G18 RELAY 16 RELAY 15

C22

NOTES 1.

(a)

C.T. SHORTING LINKS

2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY. 3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY. 4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU. 5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.

CASE EARTH

POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY

Figure 31: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 16 O/P) P14x Technical Data Sheet 62 P141/2/3/4/5 Software Version 44J

(b)

PIN TERMINAL (P.C.B. TYPE)

P1607ENa

P2275ENa

Figure 32: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 20 O/P with 4 High Break Contacts) P14x Technical Data Sheet 63 P141/2/3/4/5 Software Version 44J

MiCOM P145 (PART)


J11 J12 A X X X A F5 N F7 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 G1 G2 G3 G4 OPTO 3 G5 G6 G7 G8 G9 G10 G11 J17 SEE DRAWING 10Px4001. EIA485/ KBUS PORT + J18 J16 SCN G12 G13 G14 G15 G16 G17 G18 E1 COMMON CONNECTION E2 AC OR DC J1 RELAY 16 RELAY 15 COMMS NOTE 5. RELAY 8 RELAY 7 RELAY 4 RELAY 5 RELAY 6 OPTO 11 F6 H6 H5 H4 RELAY 3 ANY TRIP NOTE 3. RELAY 2 B C C B PHASE ROTATION OPTO 10 F4 H3 C F3 H2 RELAY 1 B OPTO 9 F2 H1 J14 A F1 WATCHDOG CONTACT J13 WATCHDOG CONTACT

DIRECTION OF FORWARD CURRENT FLOW

P2

P1 P2

P1

S2

S1

S2

S1

MiCOM P145 (PART)


C1 A 5A

A C3 C4 5A OPTO 13 F10 F11 OPTO 14 F12 F13 OPTO 15 F14 F15 + + + + + + + + OPTO 8 OPTO 7 OPTO 6 OPTO 5 OPTO 4 OPTO 2 F18 NOTE 4. COMMON CONNECTION F17 OPTO 1 OPTO 16 F16 D1 D2 D3 D4 C12 C13 D7 D8 C15 A C19 D11 D12 D13 B C20 D14 D15 D16 C C21 D18 D17 D10 1A D9 N SENSITIVE 5A D6 1A D5
V CHECK SYNC

B C 1A C23 F8 F9

n
OPTO 12

NOTE 2.

N B C6 C7 C C9 C10 5A N 1A 5A 1A C24

a b c

a b c

RELAY 9 RELAY 10 RELAY 11 RELAY 12 RELAY 13 RELAY 14

RELAY 17

*
x AUX SUPPLY
+ + + 48V DC FIELD VOLTAGE OUT J2 J7 J8 J9 J10

E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 CASE EARTH E15 E16 E17 E18

RELAY 18 RELAY 19 RELAY 20 RELAY 21 RELAY 22 RELAY 23

N C22

NOTES 1.

(a)

C.T. SHORTING LINKS

2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY.


3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY.

(b)

PIN TERMINAL (P.C.B. TYPE)

4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU.
5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.

RELAY 24

P1611ENa

Figure 33: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 24 O/P) P14x Technical Data Sheet 64 P141/2/3/4/5 Software Version 44J
*
POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY

P2276ENa

Figure 34: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 24 O/P with 8 High Break Contacts) P14x Technical Data Sheet 65 P141/2/3/4/5 Software Version 44J

P2277ENa

Figure 35: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 28 O/P with 4 High Break Contacts) P14x Technical Data Sheet 66 P141/2/3/4/5 Software Version 44J

DIRECTION OF FORWARD CURRENT FLOW X X X A WATCHDOG CONTACT J12 J13 J14 H1 H2 H3 H4 H5 H6 H7 H8 H9 RELAY 5 H10 H11 OPTO 3 H13 RELAY 7 H15 H16 RELAY 8 H17 H18 G1 G2 G3 RELAY 10 RELAY 11 OPTO 8 RELAY 12 RELAY 13 RELAY 14 RELAY 15 G4 G5 G6 G7 G8 G9 G10 G11 OPTO 9 G12 G13 G14 G15 G16 OPTO 11 RELAY 16 G17 G18 H14 RELAY 6 H12 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 RELAY 32 RELAY 31 RELAY 24 RELAY 23 RELAY 22 RELAY 20 RELAY 21 E4 E3 E2 WATCHDOG CONTACT RELAY 1 RELAY 2 B C B C PHASE ROTATION J11 E1 C B A A

P2

P1 P2

P1

S2

S1

MiCOM P145 (PART)


RELAY 17 RELAY 18 RELAY 19

S2

S1

MiCOM P145 (PART)


C1 5A C23 A C3 C4 B D2 C6 C7 D4 D5 C9 C10 N D9 C12 C13 D12 D13 C15 A C19 D16 D17 D18 B C20 F1 F2 F3 C C21 F5 F6 N + + + F11 F12 F13 F14 F15 F16 F17 F18 + + + + F4 OPTO 10 + COMMON CONNECTION + D15 + + OPTO 7 OPTO 6 RELAY 9 N SENSITIVE 1A D10 D11 + OPTO 5 D8 + OPTO 4 5A D7 1A D6 + + OPTO 2 C 5A 1A D3 NOTE 4. + RELAY 4 OPTO 1 D1 ANY TRIP RELAY 3 NOTE 3. 5A 1A C24 V CHECK SYNC N

n a b c

NOTE 2.

b c

RELAY 25 RELAY 26 RELAY 27 RELAY 28 RELAY 29 RELAY 30

5A

1A
D14

C22
F8 F9 F10

F7

J1 J2

OPTO 12 COMMS NOTE 5. OPTO 13 J17 OPTO 14 OPTO 15 SEE DRAWING 10Px4001. EIA485/ KBUS PORT OPTO 16 + J18 J16 SCN + J7 J8 J9 J10 + + -

x AUX SUPPLY

AC OR DC

NOTES:

1.

2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY.

48V DC FIELD VOLTAGE OUT

(a)

C.T. SHORTING LINKS

3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY.

(b)

PIN TERMINAL (P.C.B. TYPE)

4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU.

CASE EARTH COMMON CONNECTION

P1614ENa

Figure 36: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (16 I/P & 32 O/P) P14x Technical Data Sheet 67 P141/2/3/4/5 Software Version 44J
*
POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY

5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.

DIRECTION OF FORWARD CURRENT FLOW P1 X A B A OPTO 11 F6 F7 OPTO 12 F8 F9 OPTO 13 F10 F11 OPTO 14 F12 F13 OPTO 15 F14 F15
C8

P2 F2 F3 OPTO 10 F4 F5 J14 H1 H2 H3 H4 H5 H6 RELAY 3 ANY TRIP NOTE 3. RELAY 4 RELAY 5 RELAY 6 RELAY 7 H15 H16 H17 H18 G1 G2 G3 G4 G5 G6 G7 G8 E8 E9 OPTO 21 E10 E11 OPTO 22 E12 E13 OPTO 23 E14 E15 OPTO 24 E16 E17 COMMON CONNECTION E18 G9 G10 G11 G12 G13 G14 G15 G16 G17 G18 H7 H8 H9 H10 H11 H12 H13 H14 RELAY 2 RELAY 1 WATCHDOG CONTACT C B PHASE ROTATION J12 J13 WATCHDOG CONTACT J11 X X B C C

P1 P2

A OPTO 9

F1

MiCOM P145 (PART)

S2

S1

S2

S1

MiCOM P145 (PART)


C1 N A
C2

5A

A C3 C4 5A C23 V CHECK SYNC B


C5

B C 1A

n a b c

NOTE 2.

n
C6 C7 C 1A 5A D3 + OPTO 17 E2 E3 OPTO 18 E4 E5 OPTO 19 E6 E7 OPTO 20 + + + + + + COMMON CONNECTION OPTO 8 OPTO 7 OPTO 6 OPTO 5 OPTO 4 OPTO 3 OPTO 2 E1 D4 1A 5A D7
C14

1A C24 5A OPTO 16 + NOTE 4. F18 OPTO 1 COMMON CONNECTION F17 F16

a b c
D1 D2

C9 C10 N
C11

RELAY 8

D5 D6

N SENSITIVE D8 1A D9 D10 D11 D12 D13 B C20 D14 D15 D16 C C21 D18 D17 C15 A C19

C12 C13

RELAY 9 RELAY 10 RELAY 11 RELAY 12 RELAY 13 RELAY 14 RELAY 15

RELAY 16

N C22

J1 J2 COMMS NOTE 5. J7 J8

+ + + - J17 EIA485/ KBUS PORT + J18 J16 SCN SEE DRAWING 10Px4001. J9 J10 -

x AUX SUPPLY

AC OR DC

NOTES 1.

(a)

C.T. SHORTING LINKS

2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY. 3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY. 4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU. 5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.

48V DC FIELD VOLTAGE OUT

(b)

PIN TERMINAL (P.C.B. TYPE)

CASE EARTH

P1610ENa

Figure 37: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (24 I/P & 16 O/P) P14x Technical Data Sheet 68 P141/2/3/4/5 Software Version 44J
*
POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY

P2278ENa

Figure 38: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (24 I/P & 20 O/P with 4 High Break Contacts) P14x Technical Data Sheet 69 P141/2/3/4/5 Software Version 44J

DIRECTION OF FORWARD CURRENT FLOW P1 X A B A B C C C B PHASE ROTATION X X A

P2

P1 P2

MiCOM P145 (PART)


J11 J12 J13 J14 H1 H2 RELAY 1 RELAY 2 RELAY 3 ANY TRIP NOTE 3. RELAY 4 RELAY 5 RELAY 6 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 G1 G2 G3 G4 G5 G6 G7 G8 G9 G10 E14 E15 OPTO 24 E16 E17 E18 G11 G12 G13 G14 G15 G16 COMMON CONNECTION G17 G18
COMMS NOTE 5.

WATCHDOG CONTACT WATCHDOG CONTACT

S2

S1

F9 OPTO 13 F10 F11 OPTO 14 F12 F13 OPTO 15 F14 F15 OPTO 16 F16 F17 F18 E1 OPTO 17 E2 E3 COMMON CONNECTION

S2

S1

MiCOM P145 (PART)


C1
N A

5A

B C

n
C3 C4 5A
V CHECK SYNC

NOTE 2.

1A C23

N B

a b c

n
C6 C7
C

1A C24 5A D1 + +
E6 E7 OPTO 20 E8 E9 OPTO 21 E10 E11 OPTO 22 E12 E13 OPTO 23
NOTE 4.

a b c
D2
OPTO 18 E4 E5 OPTO 19

RELAY 7

OPTO 1

C9 C10 5A D4 D5 + + + + + + COMMON CONNECTION


+ + + + OPTO 12 OPTO 11 OPTO 10 OPTO 9
-

1A D3 OPTO 2

RELAY 8

RELAY 9 RELAY 10 RELAY 11 RELAY 12 RELAY 13 RELAY 14

C12 C13 5A D8 D9 C15


A

1A D7 OPTO 4

D6

OPTO 3

N SENSITIVE

1A D10 D11 D12 D13 D14 OPTO 7 OPTO 6

OPTO 5

C19

C20 D15 D16 D17 OPTO 8

RELAY 15

RELAY 16

C21
F1

D18

B1 B2
J17 SEE DRAWING 10Px4001. EIA485/ KBUS PORT + J18 J16 SCN

RELAY 17 B3 B4 B5 B6 B7 B8 J1 RELAY 18 RELAY 19 RELAY 20

C22
F3 F4 F5 F6 F7 F8

F2

NOTES 1.

(a)

C.T. SHORTING LINKS

(b)

PIN TERMINAL (P.C.B. TYPE)

x AUX SUPPLY

AC OR DC

*
+ + J2 J7

B9 B10 B11 B12 B13

RELAY 21 RELAY 22

2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY.


CASE EARTH 48V DC FIELD VOLTAGE OUT

3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY.

+ -

J8 J9 J10

B14 B15 B16 B17 B18

RELAY 23

4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU.

RELAY 24

5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.

P1612ENa

Figure 39: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (24 I/P & 24 O/P) P14x Technical Data Sheet 70 P141/2/3/4/5 Software Version 44J
* POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY

DIRECTION OF FORWARD CURRENT FLOW P1 X X OPTO 17 E2 E3 OPTO 18 E4 E5 OPTO 19 E6 E7 OPTO 20 E8 E9 OPTO 21 E10 E11 OPTO 22 E12 E13 OPTO 23 E14 E15 OPTO 24 E16 E17 E18 B1 OPTO 25 B2 B3 OPTO 26 B4 B5 OPTO 27 B6 B7 OPTO 28 B8 B9 OPTO 29 B10 B11 OPTO 30 B12 B13 OPTO 31 B14 B15 OPTO 32 B16 B17 OPTO 12 COMMON CONNECTION + + F11 F12 F13 F14 F15 F16 F17 F18 + + + OPTO 13 COMMS NOTE 5. OPTO 14 J17 OPTO 15 EIA485/ KBUS PORT OPTO 16 COMMON CONNECTION SEE DRAWING 10Px4001. + J18 J16 SCN B18 + + + + + + + + COMMON CONNECTION + + + OPTO 11 OPTO 10 OPTO 9 OPTO 8 OPTO 7 OPTO 6 OPTO 5 OPTO 4 COMMON CONNECTION OPTO 3 OPTO 2 NOTE 4. OPTO 1 H5 H6 H7 H3 H4 RELAY 1 RELAY 2 J14 H1 H2 WATCHDOG CONTACT WATCHDOG CONTACT J11 J12 J13 C B PHASE ROTATION X A B C C B E1 A A

P2

P1 P2

S2

S1

MiCOM P145 (PART)

S2

S1

MiCOM P145 (PART)


C1 A C3 C4 5A D1 D2 1A D3 D4 D5 1A 5A D8 D9 1A 5A D12 D13 C15 A C19 D16 D17 D18 B C20 F1 F2 F3 C C21 F5 F6 N C22 F8 F9 F10 F7 F4 D15 1A D14 D11 D10 D7 D6 5A C6 C7 C B 1A C24
V CHECK SYNC

5A

C23

n a b c

B C

NOTE 2.

RELAY 3 ANY TRIP NOTE 3. RELAY 4 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 G1 G2 G3 RELAY 5 RELAY 6 RELAY 7

a b c

C9 C10 N C12 C13

RELAY 8

N SENSITIVE

RELAY 9 RELAY 10 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G14 G15 G16 G17 G18 RELAY 11 RELAY 12 RELAY 13 RELAY 14 RELAY 15

RELAY 16

J1 J2 J7 J8 J9 J10

+ + + -

x AUX SUPPLY

AC OR DC

NOTES:

1.

2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY.

(a)

C.T. SHORTING LINKS

3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY.

48V DC FIELD VOLTAGE OUT

(b)

PIN TERMINAL (P.C.B. TYPE)

4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU.

5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.

CASE EARTH

P1613ENa

Figure 40: P145 Feeder Management Relay - Directional Phase Overcurrent and SEF with Auto-reclose and Check Synchronizing (32 I/P & 16 O/P) P14x Technical Data Sheet 71 P141/2/3/4/5 Software Version 44J
*
POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY

Ordering Options
Information Required with Order
Relay Type (Feeder Management Relay) Auxiliary Voltage Rating 24 - 48V dc only 48 - 125V dc (30 - 110V ac) 110 - 250V dc (100 - 240V ac) Vn rating 100 - 120V ac 380 - 480V ac (Min. 196Vac, Max. 560Vac) Hardware options Nothing IRIG-B modulated only Fiber optic converter (ST) only (except IEC 61850) IRIG-B (modulated) & fiber optic converter (ST) (except IEC 61850) Second rear Courier Second rear Courier port + InterMiCOM Second rear Courier port + InterMiCOM + IRIG-B (modulated) IRIG-B (modulated) + second rear comms. IRIG-B (de-modulated) Ethernet (100Mbps) Ethernet (100Mbps) + IRIG-B (modulated) Ethernet (100Mbps) + IRIG-B (de-modulated) Redundant Ethernet Self-Healing Ring, 2 multi-mode fiber ports + Modulated IRIG-B Redundant Ethernet Self-Healing Ring, 2 multi-mode fiber ports + Un-modulated IRIG-B Redundant Ethernet RSTP, 2 multi-mode fiber ports + Modulated IRIG-B Redundant Ethernet RSTP, 2 multi-mode fiber ports + Un-modulated IRIG-B Redundant Ethernet Dual-Homing Star, 2 multi-mode fiber ports + Modulated IRIG-B Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Un-Modulated IRIG-B Product Specific
P141 P142/4 P143

P141/2/3/4

1 2 3

1 2

1 2 3 4 7 E F 8 C 6 A B G H J K L M

No additional hardware 4 inputs + 4 relays Additional 8 optos Additional 8 relays Additional 8 optos and 8 relays Additional 16 optos Additional 16 relays Additional 4 high break relays Additional 8 inputs + 4 high break relays Additional 8 relays + 4 high break relays Additional 8 high break relays 32 inputs and 32 relays configuration (P143 only) 8 inputs and 8 relays configuration (P141 only) Protocol Options K-Bus/Courier MODBUS IEC 60870-5-103 DNP3.0 DNP3.0 over Ethernet + Courier over RS485 IEC 61850 + Courier over RS485 IEC 61850 + CS103 over RS485 Mounting Panel Mounting

A B C D E F G H J K L M N

1 2 3 4 8 6 7

P14x Technical Data Sheet

72

P141/2/3/4/5 Software Version 44J

Language Multilingual - English, French, German, Spanish Multilingual - English, French, German, Russian Multilingual - English, French, Chinese Software Version Unless specified the latest version will be delivered Settings File Default Customer Specific Hardware Suffix Original J 0 1 4 4 0 5 C

P14x Technical Data Sheet

73

P141/2/3/4/5 Software Version 44J

Relay Type (Feeder Management Relay) Auxiliary Voltage Rating 24 - 48V dc only 48 - 125V dc (30 - 110V ac) 110 - 250V dc (100 - 240V ac) Vn rating 100 - 120V ac 380 - 480V ac (Min. 196Vac, Max. 560Vac) Hardware options

P145

1 2 3

1 2

Nothing IRIG-B modulated only Fiber optic converter (ST) only (except IEC 61850) IRIG-B (modulated) & fiber optic converter (ST) (except IEC 61850) Second rear Courier Second rear Courier port + InterMiCOM Second rear Courier port + InterMiCOM + IRIG-B (modulated) IRIG-B (modulated) + second rear comms. IRIG-B (de-modulated) Ethernet (100Mbps) Ethernet (100Mbps) + IRIG-B (modulated) Ethernet (100Mbps) + IRIG-B (de-modulated) Redundant Ethernet Self-Healing Ring, 2 multi-mode fiber ports + Modulated IRIG-B Redundant Ethernet Self-Healing Ring, 2 multi-mode fiber ports + Un-modulated IRIG-B Redundant Ethernet RSTP, 2 multi-mode fiber ports + Modulated IRIG-B Redundant Ethernet RSTP, 2 multi-mode fiber ports + Un-Modulated IRIG-B Redundant Ethernet Dual-Homing Star, 2 multi-mode fiber ports + Modulated IRIG-B Redundant Ethernet Dual-Homing Star, 2 multi-mode fiber ports + Un-Modulated IRIG-B Product Specific Version with 16 output contacts & 16 digital inputs Version with 12 output contacts & 12 digital inputs Version with 16 output contacts & 24 digital inputs Version with 24 output contacts & 16 digital inputs Version with 24 output contacts & 24 digital inputs Version with 16 output contacts & 32 digital inputs Version with 32 output contacts & 16 digital inputs Additional 4 high break relays Additional 8 inputs + 4 high break relays Additional 8 relays + 4 high break relays Additional 8 high break relays Protocol Options K-Bus/Courier MODBUS IEC 60870-5-103 DNP3.0 DNP3.0 over Ethernet + Courier over RS485 IEC 61850 + Courier over RS485 IEC 61850 + CS103 over RS485 Mounting Panel Mounting Language Multilingual - English, French, German, Spanish Multilingual - English, French, German, Russian Multilingual - English, French, Chinese Software Version Unless specified the latest version will be delivered Settings File

1 2 3 4 7 E F 8 C 6 A B G H J K L M

A B C D E F G H J K L

1 2 3 4 8 6 7

0 5 C

P14x Technical Data Sheet

74

P141/2/3/4/5 Software Version 44J

Default Customer Specific Hardware Suffix Original

0 1

P14x Technical Data Sheet

75

P141/2/3/4/5 Software Version 44J