Table of Contents
Introduction................................................................................................ 3
Features and Benefits................................................................................. 4
Design Features.......................................................................................... 6
Selection Procedure ................................................................................. 13
Performance Data..................................................................................... 14
Part Load Data ......................................................................................... 20
Sound Data............................................................................................... 21
Electrical Data, General........................................................................... 26
Electrical Data, Standard Ambient .......................................................... 27
Electrical Data, High Ambient................................................................. 40
Physical Data ........................................................................................... 49
Dimensional Data .................................................................................... 56
Application Data ...................................................................................... 60
Optional Features..................................................................................... 70
Product Specification............................................................................... 72
Catalog ACZ-4
June 2005
PM ACZ-3
"Illustrations and information cover the McQuay International products at the time of publication and
we reserve the right to make changes in design and construction at anytime without notice."
The following are trademarks or registered trademarks of their respective companies: BACnet from ASHRAE;
LONMARK and LONW ORKS from Echelon Corporation; McQuay and MicroTech II from McQuay International;
Copeland's Compliant Scroll from Copeland Corporation, Sidney, Ohio and ElectroFin from AST ElectroFin Inc.
Catalog ACZ-4
Introduction
The ACZ family of air-cooled scroll condensing units offers a wide selection of units
from 10 to 155 tons. The ACZ-A series has capacities from 10 to 39 tons with a
single refrigerant circuit using a set of tandem scroll compressors. The ACZ-B
series has capacities from 30 to 155 tons with dual refrigerant circuits with either
two or three scroll compressors in each of two circuits.
The ACZ series of air-cooled scroll condensing units continues McQuays legacy of
high quality, high efficiency, latest technology and quiet operation. These features
make the ACZ family the best overall value in air-cooled condensing units available
today.
Efficient Operation
The ACZ units utilize R22 to meet the efficiency requirements of ASHRAE 90.1.
With either two or three scroll compressors for each of two refrigerant circuits,
excellent part load performance is achieved.
Compact Size
Our reputation for compact designs with small footprints to minimize space
requirements continues to be a primary feature.
Quiet Operation
The ACZ units further enhance McQuays reputation for low operating sound
levels to make these condensing units neighborhood friendly.
Figure 1, ACZ 130 (130 Tons) with Optional Full Louver Package
Catalog ACZ-4
Quiet Operation
ACZ-A units have low sound ratings through the use of scroll compressors. These
compressors are housed in a sheet metal enclosure to further reduce the levels. All
units have a sound power rating of 90 dBA or less.
Catalog ACZ-4
Excellent Part Load PerformanceLower Energy Costs for Most for the Year
By using either four or six compressors on each condensing unit, unloading characteristics and
part load performance are outstanding. The IPLV part load values for our scroll units range up
to 14.6 EER.
Integrated part load value (IPLV) is a part load performance indicator as outlined in ARI
Standard 365. The IPLV rating compares the performance of different condensing units under
identical conditions. When the IPLV is listed in EER (Energy Efficiency Ratio), a higher EER
will indicate that the chillers overall performance is better.
Catalog ACZ-4
Design Features
The McQuay ACZ Air-Cooled Condensing Unit is a product of the McQuay commitment
to offer quiet, reliable, energy efficient equipment. An approach incorporating high quality
compressors, state-of-the-art coil design, and innovative packaging.
Construction
Factory assembled and mounted on a heavy-gauge steel channel base. The base rails, supports and
cabinetry are powder-coat painted. The base distributes the unit weight for roof loading. Varied
and convenient installation is possible by virtue of the unit's small footprint.
Compressors
Copelands Compliant Scroll tandem or triple compressors are used. These rugged hermetic
compressors are constructed with an integral cast iron frame, cast iron scrolls, three Teflon
impregnated bearings, and three oil filtration devices for each compressor.
Using Copeland's Compliant Scroll tandem compressors provides two, four or six steps of capacity
modulation depending on unit model size. One compressor can run alone, depending on the load
of the system, resulting in excellent part-load efficiency. Each refrigerant circuit has specially
designed oil and gas equalization lines to control oil migration.
The design also offers radial and axial compliance (no tip seals), a large internal volume for liquid
handling, a removable suction screen, and a rotary dirt trap and oil screen. In addition, the
compressor is self-compensating for wear, handles liquid and debris, and inherently yields the
highest efficiency for its class.
This well protected compressor includes a solid-state motor protection module, 4 individual motorwinding sensors, a patented internal discharge temperature probe, and a patented shutdown feature
that prevents reverse rotation. An internal discharge check valve helps prevent shutdown noise and
comes standard with high and low pressure taps with Schrader valves, a sight glass, an oil level
adjustment valve, and an off cycle crankcase heater.
Units are available in 60 Hertz electrical voltage configurations from 208 to 575 volt operating at
3500 rpm.
Condenser Coils
Condenser coils have internally enhanced seamless copper tubes arranged in a staggered row
pattern. The coils are mechanically expanded into McQuay lanced and rippled aluminum fins with
full fin collars. A variety of optional coil material and coatings are available for corrosive
atmospheres. An integral subcooler circuit provides subcooling to greatly reduce the possibility of
liquid flashing. The external condenser coils are fitted with a protective wire mesh guard as
standard equipment.
Catalog ACZ-4
NOTES:
1. A shell-and-tube water chiller is shown. A wide variety of evaporator types can be used.
2. The filter-drier, solenoid valve, sight glass and TXV must be located as close to the evaporato
Power
Block
Disc.
Swt.
Std.
Std
Std
Opt
Opt.
Opt.
Comp.
Circuit
Breakers
Not Avail.
Std
Not Avail.
Circuit Breakers
w/ High Interr.
Capacity
Opt.
Opt.
Opt.
Panel High
Short Circuit
Current Rating
Not Avail
Opt
Opt.
Definitions:
1. Power Block, An electrical device to directly accept field wiring without any
disconnecting means.
2. Disconnect Switch, A molded case switch that accepts field wiring and disconnects
main power to the entire unit or each main power supply if the multi-point power
supply option is selected. This option does not provide overcurrent protection.
3. Compressor Circuit Breakers, A manually reset circuit breaker for each compressor,
providing compressor only protection and located ahead of the contactor. Provides
overcurrent protection for each compressor.
4. Unit Circuit Breaker with High Interrupting Capacity, A molded case circuit
breaker acting as the main disconnect switch with short circuit current rating (formally
known as withstand). Capacities are shown on page 71. One circuit breaker is
provided with each electrical circuit. The circuit breaker provides overcurrent
protection for each power supply.
5. Control Panel High Short Circuit Current Rating, (Previously known as withstand
rating). The entire control panel is designed for short circuit current rating as shown
on page 71. In the event of a short circuit, the damage is contained within the control
panel enclosure.
Control System
The MicroTech II advanced DDC unit controller surpasses all other microprocessorbased unit control systems available today. This powerful, user-friendly control system
provides the flexibility and performance needed for either stand-alone unit operation or the
controller can be easily tied into your building automation system of choice using
McQuays exclusive Protocol Selectability feature. Protocol Selectability allows you
to choose from open standard protocols such as BACnet, Modbus, and LONTALK to
communicate easily with the Building Automation System that best meets your facility
requirements. These optional communications modules are available factory-installed or
can be easily field installed.
MicroTech IIs state-of-the-art design will not only permit the unit to run more efficiently,
but will also simplify troubleshooting if a system failure occurs. Every MicroTech II
controller is programmed and tested prior to shipment to help provide a trouble-free startup.
Operator-friendly
The MicroTech II control menu structure is separated into four distinct categories that
provide the operator or service technician with a full description of current unit status,
control parameters, and alarms. Security protection helps prevent unauthorized changing of
the setpoints and control parameters.
MicroTech II continuously performs self-diagnostic checks, pressures and protection
devices, monitoring system temperatures, and it will automatically shutdown a compressor,
a refrigerant circuit or the entire unit if a fault occurs. The cause of the shutdown will be
retained in memory and can be easily displayed in plain English or metric units for operator
review.
The MicroTech II unit controller can also retain and display the time the fault occurred and
the operating conditions that were present at the time of the fault, which is an extremely
useful feature for troubleshooting. In addition to displaying alarm diagnostics, the
MicroTech II controller also provides the operator with a warning of pre-alarm conditions.
Alarm notification data can also be passed to your BAS through an optional
communications module.
Catalog ACZ-4
Staging
Temperature control for the evaporator is provided by the installer through a field supplied
temperature controller. The field supplied staging signals are provided to the MicroTech II
controller which correspondingly activates and deactivates the scroll compressors. The
temperature controller is required to close normally-open 24 volt contacts on a demand for
cooling. These closure signals are field wired to the terminal strip (TB2) in the condensing
unit. Refer to the typical field wiring diagram for details. The following control staging is
required:
Condensing Unit Model
ACZ-010A through 039A
ACZ-030B through 110B
ACZ-120B through 155B
Number of
Capacity Steps
2
4
6
Number of Required
Contact Closure Signals
2
4
6
Lead/lag is automatic and switched based on operating hours and compressor starts.
Equipment Protection
The unit is protected in two ways: (1) by alarms that shut the unit down and require manual
reset to restore unit operation and (2) by limit alarms that reduce unit operation in response
to some out-of-limit condition. Shut down alarms can activate a remote alarm signal. Limit
alarms activate a signal on the controller.
Shutdown Alarms
High condenser pressure
Motor protection system
Phase voltage protection (Optional on ACZ-B only)
Outside ambient temperature
Sensor failures
Limit Alarms
Condenser pressure stage down, unloads unit at high discharge pressures
Low ambient lockout, shuts off unit at low ambient temperatures
Low evaporator pressure hold, holds stage #1 until pressure rises
Low evaporator pressure unload, shuts off stage #2
Enables unit operation from either local keypad, digital input, or BAS
Digital Inputs
Remote start/stop
Flow switch
Digital Outputs
Catalog ACZ-4
Shutdown alarm; field wired, activates on an alarm condition, off when alarm is
cleared
Evaporator pump or air handler fan motor; field wired, starts when unit is set to
start
ACZ 010A through 155B
Enable/disable operation
Select operating mode
Set the network limit variable
Read all digital and analog inputs and outputs
Read operating mode and status
Send a description of each alarm when it occurs
Keypad/Display
A 4-line by-20 character/line liquid crystal display and 6-key keypad is mounted on the unit
controller. Its layout is shown below.
Figure 4, MicroTech II Keypad
Menu Button
"Enter" Button
The four arrow buttons (UP, DOWN, LEFT, RIGHT) have three modes of use.
Scroll between data screens as indicated by the arrows (default mode).
Select a specific data screen in a hierarchical fashion using dynamic labels on the right
side of the display (this mode is entered by pressing the MENU button).
Change field values in edit mode.
10
Catalog ACZ-4
Catalog ACZ-4
11
Features
Can be wired up to 1,640 feet (500 meters) from the unit for flexibility in placing each
remote user interface within your building.
The main control is isolated from the remote user interface wiring so that wiring problems
are less likely to damage the unit user interface.
Allows you to access the user interface for each unit from one location, inside the building.
Users need to learn one format because the remote user interface is identical to the unitmounted version.
Note:
Maximum distance between terminal
blocks is 1640 feet (500 m)
A
A
0 1 2 3 4 5 6
0 1 2 3 4 5 6
sc
sc
30 Vdc +
Power Common
RX+/Tx+
Rx-/TxShield
Communications cable is
Belden 9841 or equivalent
AWG22 twisted pair
12
Catalog ACZ-4
Selection Procedure
ACZ condensing units are selected in conjunction with some kind of evaporator equipment.
The ACZ ratings are based on saturated suction temperature at the compressor inlet and on
ambient air dry-bulb temperature. For a system selection, the ACZ condensing unit is
usually selected first, then the line loss added to the condensing unit saturated suction
temperature to determine the saturated evaporating temperature. This temperature is then
used for the selection of the evaporator, whether it is a DX coil or shell and tube heat
exchanger. The pipe size can be determined from procedures and data in the Refrigerant
Piping Section. For selection purposes, the tubing size is based on a pressure equivalent of
a two-degree F line loss (equal to about 3-psi pressure drop).
The correction for altitude found in Table 1 is applied, if applicable, by dividing the
required job capacity by the correction factor to ascertain the necessary unit capacity in the
Capacity Tables.
ACZ performance is found in Table 2 through Table 8 (I-P and SI) covering the normal
range of saturated suction temperatures and ambient air temperatures.
Catalog ACZ-4
Altitude
Capacity
Sea Level
1.000
1.000
2000 ft (610 m)
0.986
1.009
4000 ft (1220) m
0.973
1.021
6000 ft (1830) m
0.959
1.031
Power
13
Performance Data
I-P Units
Table 2, ACZ 010A through 039A
ACZ
Unit
Size
010A
013A
016A
020A
025A
028A
033A
039A
Sat
Fan &
80F
Suct. Control Unit PWR
Temp Power
Mbh kWi
(kW)
(F)
30
1.8
86.4
8.0
35
1.8
96.0
8.1
40
1.8
105.6 8.3
45
1.8
115.2 8.4
50
1.8
126.0 8.6
55
1.8
136.8 8.9
30
1.8
111.6 10.4
35
1.8
124.8 10.7
40
1.8
139.2 10.9
45
1.8
154.8 11.3
50
1.8
170.4 11.6
55
1.8
187.2 11.9
30
1.8
148.8 13.6
35
1.8
164.4 13.9
40
1.8
180.0 14.1
45
1.8
198.0 14.4
50
1.8
217.2 14.7
55
1.8
237.6 15.1
30
1.8
178.8 16.8
35
1.8
196.8 17.2
40
1.8
216.0 17.6
45
1.8
236.4 18.0
50
1.8
256.8 18.5
55
1.8
279.6 19.0
30
2.7
232.8 21.8
35
2.7
256.8 22.3
40
2.7
282.0 22.8
45
2.7
308.4 23.4
50
2.7
337.2 24.1
55
2.7
366.0 24.7
30
2.7
254.4 24.3
35
2.7
280.8 24.9
40
2.7
307.2 25.6
45
2.7
336.0 26.3
50
2.7
366.0 27.1
55
2.7
398.4 27.9
30
2.7
318.0 28.0
35
2.7
350.4 28.8
40
2.7
384.0 29.5
45
2.7
418.8 30.4
50
2.7
456.0 31.3
55
2.7
495.6 32.3
30
2.7
393.6 36.7
35
2.7
433.2 37.7
40
2.7
474.0 38.9
45
2.7
516.0 40.1
50
2.7
560.4 41.5
55
2.7
608.4 42.9
85F
PWR Unit
95F
Unit PWR Unit
Unit
115F
PWR Unit
Unit
EER
Mbh
kWi
EER Mbh
kWi
EER
Mbh
kWi
EER Mbh
kWi
EER
10.9
11.8
12.7
13.7
14.6
15.5
10.7
11.7
12.7
13.7
14.7
15.7
10.9
11.8
12.8
13.7
14.7
15.7
10.7
11.5
12.3
13.1
13.9
14.7
10.7
11.5
12.4
13.2
14.0
14.8
10.5
11.3
12.0
12.8
13.5
14.3
11.4
12.2
13.0
13.8
14.6
15.3
10.7
11.5
12.2
12.9
13.5
14.2
85.2
93.6
103.2
112.8
123.6
134.4
108.0
121.2
135.6
151.2
166.8
183.6
145.2
159.6
176.4
193.2
212.4
232.8
175.2
192.0
211.2
230.4
250.8
272.4
228.0
250.8
274.8
301.2
328.8
357.6
248.4
273.6
300.0
327.6
357.6
388.8
310.8
342.0
374.4
409.2
445.2
483.6
384.0
422.4
462.0
502.8
547.2
592.8
8.3
8.4
8.6
8.7
8.9
9.2
10.9
11.1
11.4
11.7
12.0
12.4
14.2
14.5
14.7
15.0
15.3
15.7
17.5
17.9
18.3
18.8
19.3
19.8
22.7
23.2
23.8
24.3
25.0
25.7
25.3
25.9
26.6
27.3
28.1
28.9
29.3
30.0
30.8
31.7
32.6
33.6
38.2
39.3
40.5
41.8
43.1
44.6
10.2
11.1
12.0
12.9
13.8
14.6
10.0
11.0
11.9
12.9
13.9
14.8
10.2
11.1
12.0
12.9
13.8
14.8
10.0
10.7
11.5
12.3
13.0
13.8
10.0
10.8
11.6
12.4
13.2
13.9
9.8
10.6
11.3
12.0
12.7
13.4
10.6
11.4
12.2
12.9
13.7
14.4
10.1
10.7
11.4
12.1
12.7
13.3
8.9
9.1
9.2
9.4
9.6
9.8
11.8
12.1
12.3
12.6
13.0
13.3
15.5
15.7
16.0
16.3
16.6
17.0
19.1
19.5
20.0
20.4
20.9
21.4
24.7
25.2
25.8
26.3
27.0
27.7
27.4
28.1
28.8
29.5
30.3
31.1
32.1
32.8
33.7
34.5
35.5
36.5
41.5
42.7
43.9
45.2
46.6
48.1
9.0
9.8
10.6
11.4
12.2
13.0
8.7
9.6
10.5
11.4
12.3
13.1
8.9
9.7
10.5
11.3
12.1
13.0
8.6
9.3
10.0
10.7
11.4
12.0
8.8
9.4
10.1
10.8
11.6
12.3
8.6
9.2
9.9
10.5
11.2
11.8
9.2
9.9
10.6
11.3
11.9
12.6
8.8
9.4
9.9
10.5
11.1
11.6
75.6
84.0
92.4
100.8
110.4
121.2
97.2
109.2
122.4
135.6
151.2
165.6
130.8
144.0
159.6
175.2
192.0
210.0
156.0
171.6
188.4
206.4
224.4
243.6
202.8
224.4
246.0
270.0
294.0
320.4
220.8
243.6
267.6
294.0
320.4
348.0
278.4
306.0
336.0
367.2
400.8
434.4
340.8
374.4
410.4
447.6
487.2
526.8
9.7
9.8
10.0
10.1
10.3
10.6
12.9
13.2
13.4
13.7
14.1
14.4
17.0
17.2
17.5
17.8
18.1
18.5
20.9
21.3
21.8
22.2
22.7
23.3
26.8
27.4
28.0
28.6
29.2
29.9
29.8
30.5
31.2
32.0
32.8
33.6
35.1
35.9
36.7
37.7
38.7
39.7
45.0
46.3
47.6
49.0
50.4
52.0
7.8
8.5
9.2
10.0
10.7
11.4
7.5
8.3
9.1
9.9
10.7
11.5
7.7
8.4
9.1
9.8
10.6
11.3
7.5
8.1
8.7
9.3
9.9
10.5
7.6
8.2
8.8
9.4
10.1
10.7
7.4
8.0
8.6
9.2
9.8
10.3
7.9
8.5
9.2
9.8
10.4
10.9
7.6
8.1
8.6
9.1
9.7
10.1
10.5
10.6
10.8
11.0
11.2
11.4
14.1
14.4
14.7
15.0
15.3
15.7
18.5
18.8
19.1
19.4
19.7
20.1
22.7
23.2
23.7
24.2
24.7
25.3
29.2
29.8
30.4
31.1
31.7
32.5
32.4
33.1
33.9
34.7
35.5
36.4
38.3
39.2
40.1
41.1
42.1
43.2
48.7
50.1
51.5
52.9
54.5
56.1
6.8
7.4
8.0
8.7
9.3
10.0
6.4
7.1
7.8
8.5
9.3
10.0
6.6
7.2
7.8
8.5
9.1
9.8
6.4
6.9
7.5
8.0
8.5
9.1
6.5
7.0
7.6
8.2
8.7
9.3
6.4
6.9
7.4
7.9
8.4
9.0
6.8
7.4
7.9
8.4
8.9
9.5
6.5
7.0
7.4
7.9
8.3
8.8
80.4
88.8
97.2
106.8
117.6
127.2
103.2
115.2
129.6
144.0
158.4
175.2
138.0
152.4
168.0
184.8
201.6
220.8
165.6
182.4
199.2
218.4
237.6
258.0
216.0
237.6
261.6
285.6
312.0
339.6
235.2
259.2
284.4
310.8
339.6
368.4
295.2
324.0
355.2
388.8
423.6
459.6
363.6
399.6
436.8
476.4
517.2
560.4
Unit
105F
PWR Unit
Unit
70.8
78.0
86.4
94.8
104.4
114.0
91.2
102.0
115.2
128.4
141.6
156.0
123.6
135.6
150.0
164.4
180.0
198.0
146.4
160.8
176.4
193.2
211.2
229.2
189.6
210.0
230.4
253.2
276.0
301.2
206.4
228.0
250.8
274.8
300.0
326.4
261.6
288.0
315.6
345.6
376.8
408.0
315.6
348.0
381.6
417.6
453.6
492.0
NOTES:
1.
2.
3.
4.
14
Catalog ACZ-4
030B
5.6
035B
5.6
040B
5.6
045B
5.6
050B
5.6
055B
5.7
060B
5.7
065B
5.7
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
Unit
Mbh
306
338
372
410
451
496
341
376
415
456
500
548
376
415
457
502
550
601
436
482
531
583
639
699
484
535
589
647
708
774
534
590
650
714
783
856
593
655
720
791
866
945
652
719
791
867
949
1034
75
PWR
kWi
27.2
27.6
28.1
28.6
29.2
29.9
30.0
30.5
31.1
31.8
32.5
33.3
32.8
33.5
34.2
34.9
35.8
36.7
37.4
38.0
38.7
39.4
40.3
41.2
42.5
43.4
44.3
45.3
46.3
47.5
45.7
46.6
47.5
48.5
49.6
50.8
50.8
51.9
53.1
54.4
55.9
57.5
55.8
57.2
58.7
60.4
62.2
64.2
Unit
EER
11.2
12.2
13.3
14.3
15.5
16.6
11.3
12.3
13.3
14.4
15.4
16.5
11.4
12.4
13.4
14.4
15.4
16.4
11.7
12.7
13.7
14.8
15.9
17.0
11.4
12.3
13.3
14.3
15.3
16.3
11.7
12.7
13.7
14.7
15.8
16.9
11.7
12.6
13.6
14.5
15.5
16.4
11.7
12.6
13.5
14.4
15.3
16.1
Unit
Mbh
290
321
354
391
430
473
323
357
394
433
476
522
357
394
434
476
522
571
414
458
504
554
607
664
460
508
560
615
673
736
509
562
619
680
745
814
564
623
686
753
824
900
620
684
753
826
904
986
85
PWR
kWi
29.7
30.2
30.6
31.2
31.8
32.6
32.9
33.5
34.1
34.8
35.5
36.4
36.1
36.8
37.6
38.4
39.3
40.2
41.1
41.8
42.5
43.3
44.1
45.1
46.7
47.6
48.5
49.6
50.7
51.9
50.1
51.0
51.9
52.9
54.0
55.2
55.8
57.0
58.3
59.7
61.2
62.8
61.6
63.0
64.6
66.4
68.3
70.5
105
PWR
kWi
35.9
36.4
36.9
37.6
38.3
39.1
39.8
40.5
41.2
42.0
42.9
43.8
43.8
44.6
45.5
46.5
47.5
48.6
49.7
50.5
51.4
52.3
53.3
54.3
56.4
57.5
58.7
59.9
61.2
62.6
60.5
61.6
62.7
63.9
65.1
66.4
67.7
69.1
70.6
72.2
74.0
75.8
74.9
76.7
78.6
80.6
82.9
85.3
Unit
EER
7.3
7.9
8.6
9.3
10.1
10.9
7.2
7.9
8.5
9.2
9.9
10.6
7.2
7.8
8.5
9.1
9.8
10.5
7.4
8.1
8.7
9.4
10.2
10.9
7.2
7.8
8.5
9.1
9.8
10.5
7.4
8.1
8.8
9.5
10.2
10.9
7.4
8.0
8.6
9.3
9.9
10.6
7.4
8.0
8.5
9.1
9.7
10.3
Unit
Mbh
243
270
298
328
361
397
269
298
329
362
398
437
295
326
360
397
435
476
343
380
420
462
507
555
376
417
461
508
558
611
415
462
511
563
619
678
466
516
570
627
687
752
517
571
629
690
756
826
115
PWR
kWi
39.5
40.1
40.7
41.3
42.0
42.9
43.9
44.6
45.4
46.2
47.2
48.2
48.2
49.1
50.1
51.2
52.3
53.5
54.6
55.6
56.5
57.5
58.6
59.8
62.0
63.3
64.6
65.9
67.4
68.9
66.6
67.8
69.1
70.4
71.7
73.2
74.5
76.1
77.8
79.6
81.5
83.5
82.4
84.4
86.6
88.8
91.2
93.8
Unit
EER
6.2
6.7
7.3
7.9
8.6
9.3
6.1
6.7
7.2
7.8
8.4
9.1
6.1
6.6
7.2
7.7
8.3
8.9
6.3
6.8
7.4
8.0
8.7
9.3
6.1
6.6
7.1
7.7
8.3
8.9
6.2
6.8
7.4
8.0
8.6
9.3
6.3
6.8
7.3
7.9
8.4
9.0
6.3
6.8
7.3
7.8
8.3
8.8
NOTES:
1. Ratings based on HCFC-22 and sea level altitude.
2. Interpolation is allowed; extrapolation is not permitted. Consult McQuay for performance outside the cataloged ratings.
3. KWi and EER are for the entire unit, including compressors, fan motors and control power.
4. Shaded ratings are ARI Standard 365-2002 standard rating of 95F ambient air temperature and 45F suction with 15 degrees
superheat.
Catalog ACZ-4
15
Sat.
Fan &
Control Suct.
Power Temp.
(kW)
(F)
070B
7.3
080B
7.3
090B
10.9
100B
10.9
110B
10.9
120B
14.5
130B
14.5
140B
14.5
155B
14.5
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
Unit
Mbh
773
851
934
1022
1117
748
825
907
997
1092
1195
850
938
1034
1137
1250
1372
937
1034
1138
1251
1372
1502
1024
1129
1243
1364
1494
1633
1131
1247
1373
1508
1653
1809
1273
1404
1547
1701
1869
2050
1402
1546
1702
1870
2051
2246
1531
1688
1858
2039
2234
2442
75
PWR
kWi
61.8
63.4
65.3
67.3
69.5
65.8
67.6
69.6
71.8
74.2
76.9
73.3
75.2
77.1
79.2
81.5
84.0
80.2
82.3
84.6
87.1
89.9
92.9
87.0
89.4
92.1
95.0
98.3
101.8
96.6
98.8
101.3
103.9
106.8
110.0
110.5
113.6
116.8
120.4
124.3
128.5
121.5
125.0
128.9
133.1
137.7
142.8
132.4
136.4
140.9
145.7
151.1
157.1
Unit
EER
12.5
13.4
14.3
15.2
16.1
11.4
12.2
13.0
13.9
14.7
15.5
11.6
12.5
13.4
14.4
15.3
16.3
11.7
12.6
13.5
14.4
15.3
16.2
11.8
12.6
13.5
14.4
15.2
16.0
11.7
12.6
13.6
14.5
15.5
16.4
11.5
12.4
13.2
14.1
15.0
16.0
11.5
12.4
13.2
14.1
14.9
15.7
11.6
12.4
13.2
14.0
14.8
15.5
Unit
Mbh
736
810
890
974
1065
711
784
864
949
1040
1138
810
894
986
1085
1192
1308
891
984
1084
1192
1309
1434
973
1074
1183
1300
1426
1560
1077
1189
1309
1439
1578
1727
1212
1338
1474
1622
1782
1954
1332
1471
1621
1782
1955
2142
1453
1604
1767
1942
2129
2329
85
PWR
kWi
67.8
69.5
71.4
73.5
75.8
72.1
74.1
76.2
78.5
81.1
83.9
79.7
81.6
83.6
85.8
88.2
90.8
87.2
89.4
91.7
94.3
97.1
100.1
94.7
97.1
99.8
102.7
105.9
109.5
105.5
107.8
110.3
113.1
116.1
119.4
120.4
123.6
127.0
130.8
134.8
139.2
132.3
136.0
140.0
144.4
149.2
154.5
144.3
148.5
153.0
158.0
163.5
169.7
105
PWR
kWi
81.9
84.0
86.2
88.6
91.2
87.1
89.4
91.9
94.6
97.5
100.6
95.2
97.3
99.6
102.0
104.6
107.5
103.9
106.4
109.0
111.9
115.0
118.3
112.6
115.5
118.5
121.8
125.3
129.2
126.9
129.5
132.4
135.5
138.8
142.5
144.4
148.0
151.9
156.1
160.6
165.6
158.3
162.6
167.2
172.2
177.6
183.5
172.1
177.1
182.4
188.2
194.5
201.4
Unit
EER
8.0
8.6
9.2
9.8
10.5
7.2
7.8
8.4
9.0
9.5
10.1
7.6
8.2
8.9
9.5
10.2
10.9
7.6
8.3
8.9
9.6
10.2
10.9
7.7
8.3
8.9
9.6
10.2
10.9
7.6
8.2
8.8
9.5
10.2
10.9
7.5
8.1
8.7
9.3
9.9
10.6
7.5
8.1
8.7
9.3
9.9
10.5
7.5
8.1
8.7
9.2
9.8
10.4
Unit
Mbh
613
677
745
817
894
587
651
719
792
870
954
672
747
827
913
1006
1106
743
824
911
1005
1106
1215
814
901
996
1097
1207
1324
895
992
1097
1209
1329
1458
1000
1112
1232
1361
1499
1647
1108
1229
1359
1499
1650
1812
1216
1346
1486
1638
1801
1976
115
PWR
kWi
90.2
92.4
94.8
97.4
100.2
96.0
98.5
101.2
104.1
107.2
110.6
104.6
106.9
109.3
111.8
114.6
117.6
113.8
116.6
119.5
122.6
125.9
129.5
123.1
126.3
129.7
133.3
137.2
141.3
139.5
142.5
145.6
148.9
152.5
156.4
159.1
162.9
167.0
171.5
176.3
181.6
173.6
178.4
183.5
188.9
194.8
201.2
188.2
193.9
199.9
206.3
213.3
220.8
Unit
EER
6.8
7.3
7.9
8.4
8.9
6.1
6.6
7.1
7.6
8.1
8.6
6.4
7.0
7.6
8.2
8.8
9.4
6.5
7.1
7.6
8.2
8.8
9.4
6.6
7.1
7.7
8.2
8.8
9.4
6.4
7.0
7.5
8.1
8.7
9.3
6.3
6.8
7.4
7.9
8.5
9.1
6.4
6.9
7.4
7.9
8.5
9.0
6.5
6.9
7.4
7.9
8.4
8.9
NOTES:
1. Ratings based on HCFC-22 and sea level altitude.
2. Interpolation is allowed; extrapolation is not permitted. Consult McQuay for performance outside the cataloged ratings.
3. KWi and EER are for the entire unit, including compressors, fan motors and control power.
4. Shaded ratings are ARI Standard 365-2002 standard rating of 95F ambient air temperature and 45F suction with 15 degrees
superheat.
16
Catalog ACZ-4
SI Units
Table 5, ACZ 010A - ACZ 039A
Ambient Air Temperature (C)
Sat
Fan &
Suct. Control
24C
30C
35C
41C
47C
Temp Power Unit PWR Unit Unit PWR Unit Unit PWR Unit Unit PWR Unit Unit PWR Unit
(kW)
(C)
kW kWi COP
kW
kWi COP kW
kWi COP kW
kWi COP kW
kWi COP
-1
1.8
26.1 7.7
3.4
24.8
8.4
3.0
23.6 8.9
2.6 22.1
9.7
2.3 20.6 10.6
1.9
2
1.8
29.0 7.9
3.7
27.6
8.5
3.2
26.3 9.1
2.9 24.7
9.9
2.5 23.0 10.8
2.1
5
1.8
32.1 8.0
4.0
30.6
8.7
3.5
29.1 9.3
3.1 27.4 10.1 2.7 25.6 11.0
2.3
010A
8
1.8
35.4 8.2
4.3
33.7
8.9
3.8
32.2 9.5
3.4 30.3 10.3 3.0 28.4 11.2
2.5
11
1.8
38.9 8.5
4.6
37.1
9.1
4.1
35.4 9.7
3.7 33.4 10.5 3.2 31.3 11.4
2.7
13
1.8
41.4 8.6
4.8
39.4
9.2
4.3
37.7 9.8
3.8 35.5 10.7 3.3 33.3 11.6
2.9
-1
1.8
33.5 10.0
3.3
31.8 11.0
2.9
30.3 11.8 2.6 28.5 13.0 2.2 26.5 14.4
1.8
2
1.8
37.9 10.3
3.7
36.0 11.2
3.2
34.4 12.1 2.8 32.4 13.3 2.4 30.1 14.7
2.1
5
1.8
42.6 10.6
4.0
40.5 11.5
3.5
38.7 12.4 3.1 36.5 13.6 2.7 34.1 15.0
2.3
013A
8
1.8
47.6 11.0
4.3
45.3 11.9
3.8
43.4 12.7 3.4 40.9 13.9 2.9 38.2 15.3
2.5
11
1.8
52.9 11.3
4.7
50.4 12.2
4.1
48.2 13.1 3.7 45.5 14.3 3.2 42.7 15.7
2.7
13
1.8
56.5 11.6
4.9
53.9 12.5
4.3
51.6 13.3 3.9 48.7 14.5 3.4 45.7 15.9
2.9
-1
1.8
44.8 13.1
3.4
42.4 14.4
3.0
40.6 15.5 2.6 38.3 17.1 2.2 35.8 18.8
1.9
2
1.8
49.8 13.4
3.7
47.2 14.6
3.2
45.2 15.8 2.9 42.6 17.4 2.5 39.9 19.1
2.1
5
1.8
55.1 13.7
4.0
52.4 14.9
3.5
50.1 16.1 3.1 47.3 17.7 2.7 44.3 19.4
2.3
016A
8
1.8
61.0 14.0
4.4
57.9 15.2
3.8
55.5 16.4 3.4 52.4 18.0 2.9 49.0 19.8
2.5
11
1.8
67.3 14.3
4.7
64.0 15.6
4.1
61.2 16.8 3.6 57.8 18.4 3.1 54.1 20.2
2.7
13
1.8
71.7 14.6
4.9
68.2 15.9
4.3
65.3 17.0 3.8 61.6 18.7 3.3 57.6 20.4
2.8
-1
1.8
54.0 16.1
3.3
51.1 17.7
2.9
48.7 19.1 2.5 45.6 21.0 2.2 42.5 23.1
1.8
2
1.8
59.8 16.5
3.6
56.7 18.1
3.1
54.0 19.6 2.8 50.7 21.5 2.4 47.3 23.6
2.0
5
1.8
66.1 17.0
3.9
62.6 18.6
3.4
59.6 20.1 3.0 56.0 22.0 2.5 52.3 24.1
2.2
020A
8
1.8
72.6 17.5
4.2
68.8 19.1
3.6
65.6 20.6 3.2 61.6 22.5 2.7 57.5 24.7
2.3
11
1.8
79.6 18.0
4.4
75.4 19.6
3.8
71.9 21.1 3.4 67.5 23.1 2.9 63.1 25.3
2.5
13
1.8
84.4 18.3
4.6
80.0 20.0
4.0
76.2 21.5 3.5 71.6 23.5 3.0 66.9 25.7
2.6
-1
2.7
70.2 21.0
3.3
66.6 22.9
2.9
63.5 24.7 2.6 59.5 27.0 2.2 55.2 29.6
1.9
2
2.7
77.9 21.5
3.6
74.0 23.5
3.2
70.5 25.3 2.8 66.1 27.6 2.4 61.5 30.3
2.0
5
2.7
86.2 22.1
3.9
81.8 24.1
3.4
78.0 25.9 3.0 73.2 28.3 2.6 68.2 31.0
2.2
025A
8
2.7
94.9 22.8
4.2
90.1 24.7
3.6
85.9 26.5 3.2 80.7 29.0 2.8 75.3 31.7
2.4
104. 23.5
11
2.7
4.4
98.8 25.4
3.9
94.3 27.2 3.5 88.6 29.7 3.0 82.7 32.4
2.6
110. 24.0
13
2.7
4.6 104.9 25.9
4.1 100.0 27.7 3.6 94.0 30.2 3.1 87.8 32.9
2.7
-1
2.7
76.7 23.4
3.3
72.8 25.5
2.9
69.3 27.5 2.5 64.7 30.0 2.2 59.8 32.8
1.8
2
2.7
85.0 24.1
3.5
80.7 26.2
3.1
76.9 28.2 2.7 72.0 30.8 2.3 66.7 33.7
2.0
5
2.7
93.9 24.8
3.8
89.2 26.9
3.3
85.0 28.9 2.9 79.7 31.6 2.5 74.0 34.5
2.1
028A
103. 25.6
8
2.7
4.0
98.1 27.7
3.5
93.5 29.7 3.1 87.7 32.4 2.7 81.6 35.4
2.3
113. 26.5
11
2.7
4.3 107.5 28.6
3.8 102.5 30.6 3.3 96.2 33.3 2.9 89.6 36.3
2.5
120. 27.1
13
2.7
4.4 113.9 29.2
3.9 108.6 31.2 3.5 102.0 33.9 3.0 95.1 36.9
2.6
-1
2.7
95.8 26.9
3.6
90.9 29.6
3.1
86.7 32.1 2.7 81.6 35.3 2.3 76.3 38.8
2.0
106. 27.7
2
2.7
3.8 100.8 30.4
3.3
96.2 32.9 2.9 90.5 36.2 2.5 84.6 39.8
2.1
117. 28.5
5
2.7
4.1 111.3 31.3
3.6 106.2 33.8 3.1 99.9 37.2 2.7 93.4 40.8
2.3
033A
128. 29.4
8
2.7
4.4 122.3 32.2
3.8 116.8 34.8 3.4 109.9 38.2 2.9 102.7 41.9
2.5
140. 30.4
11
2.7
4.6 133.9 33.2
4.0 127.9 35.9 3.6 120.3 39.3 3.1 112.5 43.1
2.6
149. 31.2
13
2.7
4.8 141.9 34.0
4.2 135.5 36.6 3.7 127.5 40.1 3.2 119.2 43.9
2.7
118. 35.3
-1
2.7
3.4 112.5 38.6
2.9 107.0 41.6 2.6 99.7 45.4 2.2 91.7 49.3
1.9
131. 36.4
2
2.7
3.6 124.4 39.8
3.1 118.4 42.8 2.8 110.5 46.7 2.4 101.9 50.8
2.0
144. 37.7
5
2.7
3.8 137.0 41.1
3.3 130.4 44.2 2.9 121.8 48.2 2.5 112.6 52.4
2.1
039A
158. 39.0
8
2.7
4.1 150.3 42.5
3.5 143.0 45.6 3.1 133.7 49.7 2.7 123.8 54.0
2.3
173. 40.5
11
2.7
4.3 164.2 44.0
3.7 156.2 47.2 3.3 146.1 51.3 2.8 135.4 55.7
2.4
183. 41.5
13
2.7
4.4 173.8 45.0
3.9 165.3 48.2 3.4 154.6 52.4 3.0 143.4 56.9
2.5
NOTES:
1.
Ratings based on HCFC-22 and sea level altitude.
2.
Interpolation is allowed; extrapolation is not permitted. Consult McQuay for performance outside the cataloged ratings.
3.
KWi and COP are for the entire unit, including compressors, fan motors and control power.
ACZ
Unit
Size
Catalog ACZ-4
17
030B
035B
040B
045B
050B
055B
060B
065B
30
35
40
45
Unit
KW
PWR Unit
kWi COP
Unit
KW
PWR Unit
kWi COP
Unit
KW
PWR Unit
kWi COP
5.6
-1.0
2.0
5.0
8.0
11.0
13.0
89.1
99.2
110.2
122.3
135.6
144.9
27.7
28.2
28.7
29.3
30.0
30.5
3.2
3.5
3.9
4.2
4.5
4.8
85.0
94.8
105.4
117.1
129.9
138.8
30.0
30.5
31.0
31.7
32.4
32.9
2.8
3.1
3.4
3.7
4.0
4.2
81.1
90.5
100.7
111.9
124.1
132.7
32.6
33.1
33.7
34.4
35.1
35.7
2.5
2.7
3.0
3.3
3.5
3.7
77.1
86.1
95.8
106.4
117.9
126.1
35.6
36.1
36.7
37.4
38.2
38.8
2.2
2.4
2.6
2.9
3.1
3.3
72.7
81.1
90.3
100.3
111.2
118.9
38.8
39.4
40.0
40.8
41.6
42.2
1.9
2.1
2.3
2.5
2.7
2.8
5.6
-1.0
2.0
5.0
8.0
11.0
13.0
99.2
110.5
122.7
135.9
150.2
160.2
30.6
31.2
31.8
32.6
33.4
34.0
3.3
3.6
3.9
4.2
4.5
4.7
94.7
105.5
117.2
129.8
143.6
153.1
33.3
33.9
34.6
35.3
36.2
36.8
2.9
3.1
3.4
3.7
4.0
4.2
90.1
100.4
111.6
123.7
136.8
146.0
36.2
36.9
37.6
38.4
39.3
40.0
2.5
2.7
3.0
3.2
3.5
3.7
85.3
95.2
105.8
117.4
129.8
138.5
39.5
40.2
41.0
41.9
42.8
43.5
2.2
2.4
2.6
2.8
3.0
3.2
80.3
89.7
99.7
110.6
122.4
130.6
43.1
43.9
44.7
45.6
46.7
47.4
1.9
2.1
2.2
2.4
2.6
2.8
5.6
-1.0
2.0
5.0
8.0
11.0
13.0
109.4
121.8
135.1
149.4
164.8
175.5
33.5
34.2
35.0
35.9
36.8
37.5
3.3
3.6
3.9
4.2
4.5
4.7
104.3
116.2
128.9
142.6
157.2
167.4
36.5
37.3
38.1
39.0
40.0
40.7
2.9
3.1
3.4
3.7
3.9
4.1
99.0
110.4
122.5
135.5
149.5
159.2
39.8
40.6
41.5
42.5
43.5
44.3
2.5
2.7
3.0
3.2
3.4
3.6
93.6
104.3
115.9
128.3
141.6
150.9
43.4
44.3
45.3
46.3
47.5
48.3
2.2
2.4
2.6
2.8
3.0
3.1
87.9
98.2
109.2
121.0
133.6
142.4
47.3
48.3
49.4
50.5
51.8
52.6
1.9
2.0
2.2
2.4
2.6
2.7
5.6
-1.0
2.0
5.0
8.0
11.0
13.0
127.1
141.5
157.0
173.7
191.7
204.2
38.2
38.9
39.6
40.4
41.4
42.0
3.3
3.7
4.0
4.3
4.6
4.9
121.2
135.0
149.9
165.9
183.0
194.9
41.5
42.3
43.1
43.9
44.9
45.6
2.9
3.2
3.5
3.8
4.1
4.3
115.2
128.3
142.5
157.8
174.1
185.5
45.2
46.0
46.9
47.8
48.8
49.5
2.6
2.8
3.0
3.3
3.6
3.7
108.8
121.4
134.9
149.4
165.0
175.8
49.3
50.2
51.1
52.1
53.2
53.9
2.2
2.4
2.6
2.9
3.1
3.3
102.4
114.3
127.2
141.0
155.7
166.0
53.7
54.7
55.7
56.8
58.0
58.8
1.9
2.1
2.3
2.5
2.7
2.8
5.6
-1.0
2.0
5.0
8.0
11.0
13.0
141.1
157.1
174.2
192.7
212.5
226.2
43.4
44.3
45.3
46.4
47.6
48.5
3.3
3.6
3.9
4.2
4.5
4.7
134.6
149.9
166.3
183.9
202.8
215.9
47.2
48.2
49.2
50.4
51.6
52.5
2.9
3.1
3.4
3.7
3.9
4.1
127.7
142.3
158.0
174.8
192.8
205.3
51.3
52.4
53.5
54.8
56.1
57.0
2.5
2.7
3.0
3.2
3.4
3.6
120.2
134.3
149.2
165.3
182.4
194.3
55.9
57.1
58.4
59.7
61.1
62.1
2.2
2.4
2.6
2.8
3.0
3.1
112.3
125.7
140.0
155.3
171.6
182.9
60.9
62.3
63.7
65.1
66.7
67.8
1.9
2.0
2.2
2.4
2.6
2.7
5.7
-1.0
2.0
5.0
8.0
11.0
13.0
155.6
173.3
192.3
212.8
234.8
250.1
46.6
47.6
48.6
49.7
50.9
51.7
3.3
3.7
4.0
4.3
4.6
4.8
148.8
165.8
183.9
203.5
224.4
238.9
50.6
51.6
52.6
53.7
55.0
55.8
2.9
3.2
3.5
3.8
4.1
4.3
141.4
157.6
175.0
193.6
213.6
227.4
55.0
56.1
57.2
58.4
59.6
60.5
2.6
2.8
3.1
3.3
3.6
3.8
133.2
148.8
165.4
183.2
202.2
215.4
60.0
61.1
62.3
63.6
65.0
65.9
2.2
2.4
2.7
2.9
3.1
3.3
124.2
139.2
155.1
172.1
190.3
202.8
65.4
66.7
68.1
69.5
70.9
71.9
1.9
2.1
2.3
2.5
2.7
2.8
5.7
-1.0
2.0
5.0
8.0
11.0
13.0
172.9
192.3
213.2
235.6
259.6
276.2
51.8
53.1
54.4
55.9
57.5
58.7
3.3
3.6
3.9
4.2
4.5
4.7
165.2
183.8
203.8
225.3
248.2
264.2
56.4
57.7
59.1
60.7
62.4
63.6
2.9
3.2
3.5
3.7
4.0
4.2
157.0
174.9
194.0
214.5
236.4
251.6
61.5
62.9
64.4
66.0
67.8
69.1
2.6
2.8
3.0
3.3
3.5
3.6
148.4
165.4
183.6
203.2
224.1
238.5
67.1
68.7
70.3
72.1
74.0
75.3
2.2
2.4
2.6
2.8
3.0
3.2
139.2
155.4
172.8
191.3
211.1
224.9
73.2
74.9
76.7
78.6
80.7
82.1
1.9
2.1
2.3
2.4
2.6
2.8
5.7
-1.0
2.0
5.0
8.0
11.0
13.0
190.1
211.3
234.0
258.4
284.3
302.3
57.0
58.5
60.2
62.1
64.2
65.6
3.3
3.6
3.9
4.2
4.4
4.6
181.5
201.9
223.7
247.1
272.1
289.4
62.3
63.9
65.7
67.6
69.8
71.3
2.9
3.2
3.4
3.7
3.9
4.06
172.7
192.1
213.0
235.4
259.3
275.8
68.0 2.5
69.7 2.8
71.7 3.0
73.7 3.2
76.0 3.4
77.7 3.55
163.6
182.0
201.9
223.2
245.9
261.6
74.2
76.2
78.3
80.5
83.0
84.7
2.2
2.4
2.6
2.8
3.0
3.09
154.2
171.6
190.4
210.5
232.0
246.9
81.0
83.1
85.4
87.8
90.5
92.3
1.9
2.1
2.2
2.4
2.6
2.68
NOTES:
1. Ratings based on HCFC-22 and sea level altitude.
2. Interpolation is allowed; extrapolation is not permitted. Consult McQuay for performance outside the cataloged ratings.
3. KWi and COP are for the entire unit, including compressors, fan motors and control power.
18
Catalog ACZ-4
Sat
Fan &
Control Suct.
Power Temp
(kW)
(C)
070B
7.3
080B
7.3
090B
10.9
100B
10.9
110B
10.9
120B
14.5
130B
14.5
140B
14.5
155B
14.5
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
-1.0
2.0
5.0
8.0
11.0
13.0
Unit
KW
204.4
227.2
251.8
278.3
306.7
326.4
217.8
242.2
268.5
297.0
327.8
349.2
247.9
275.8
306.2
339.4
375.6
401.0
273.1
303.7
337.0
373.0
412.0
439.3
298.3
331.7
367.8
406.7
448.5
477.6
329.6
366.5
406.5
449.7
496.3
528.9
371.0
412.6
458.1
507.6
561.5
599.3
408.4
454.2
503.9
557.7
615.9
656.6
445.9
495.7
549.6
607.8
670.2
713.8
25
PWR Unit
kWi COP
61.5
3.3
63.2
3.6
65.0
3.9
67.1
4.2
69.3
4.4
70.9
4.6
67.1
3.3
69.2
3.5
71.4
3.8
73.9
4.0
76.6
4.3
78.5
4.5
74.7
3.3
76.7
3.6
78.8
3.9
81.2
4.2
83.7
4.5
85.5
4.7
81.7
3.4
84.0
3.6
86.5
3.9
89.3
4.2
92.4
4.5
94.6
4.7
88.6
3.4
91.3
3.6
94.2
3.9
97.5
4.2
101.1 4.4
103.7 4.6
98.5
3.4
100.9 3.6
103.6 3.9
106.6 4.2
109.8 4.5
112.1 4.7
112.6 3.3
116.0 3.6
119.6 3.8
123.6 4.1
127.9 4.4
131.0 4.6
123.8 3.3
127.7 3.6
131.9 3.8
136.6 4.1
141.8 4.4
145.5 4.5
134.9 3.3
139.4 3.6
144.3 3.8
149.7 4.1
155.8 4.3
160.1 4.5
Unit
KW
195.2
217.2
240.8
266.3
293.6
312.6
208.0
231.4
256.8
284.1
313.6
334.2
237.1
263.9
293.2
325.0
359.7
384.1
260.9
290.4
322.5
357.2
394.8
421.0
284.7
317.0
351.8
389.3
429.8
457.9
315.1
350.7
389.2
430.8
475.7
507.0
354.7
394.8
438.4
486.0
537.6
573.9
390.0
434.1
481.9
533.7
589.7
628.8
425.3
473.3
525.3
581.4
641.7
683.8
30
PWR
kWi
66.9
68.6
70.6
72.7
75.1
76.7
72.9
75.0
77.4
80.0
82.8
84.9
80.5
82.6
84.8
87.3
89.9
91.8
88.1
90.4
93.0
95.9
99.0
101.2
95.6
98.3
101.2
104.5
108.1
110.7
106.6
109.1
111.9
115.0
118.4
120.8
121.6
125.1
128.9
133.1
137.6
140.8
133.7
137.7
142.2
147.0
152.4
156.2
145.8
150.4
155.4
161.0
167.2
171.6
40
PWR
kWi
79.4
81.4
83.6
86.1
88.7
90.6
86.4
88.9
91.6
94.5
97.7
100.0
94.4
96.7
99.2
101.9
104.8
106.8
103.1
105.8
108.7
111.8
115.2
117.6
111.8
114.9
118.2
121.7
125.7
128.5
125.8
128.7
131.8
135.2
138.9
141.6
143.3
147.2
151.4
156.0
161.0
164.6
157.1
161.7
166.7
172.2
178.2
182.4
170.8
176.2
182.0
188.4
195.3
200.3
Unit
COP
2.2
2.4
2.6
2.8
3.0
3.1
2.2
2.4
2.5
2.7
2.9
3.0
2.3
2.5
2.7
2.9
3.1
3.3
2.3
2.5
2.7
2.9
3.1
3.3
2.3
2.5
2.7
2.9
3.1
3.3
2.3
2.5
2.7
2.9
3.1
3.3
2.2
2.4
2.6
2.8
3.0
3.2
2.2
2.4
2.6
2.8
3.0
3.1
2.3
2.4
2.6
2.8
3.0
3.1
Unit
KW
165.4
184.5
205.1
227.2
250.9
267.4
175.3
195.8
218.0
241.8
267.5
285.3
200.7
224.7
250.7
278.8
309.2
330.5
221.7
247.8
276.1
306.7
339.9
363.0
242.7
270.8
301.5
334.7
370.5
395.5
267.2
298.6
332.5
369.0
408.4
435.8
299.0
334.9
373.7
415.6
460.9
492.6
330.7
369.7
411.9
457.5
506.9
541.3
362.5
404.4
450.1
499.5
552.8
590.1
45
PWR
kWi
86.6
88.8
91.2
93.8
96.6
98.6
94.3
97.0
99.9
103.0
106.4
108.8
102.8
105.2
107.8
110.6
113.7
115.8
112.0
114.9
118.0
121.3
125.0
127.5
121.1
124.5
128.2
132.1
136.3
139.2
137.1
140.2
143.6
147.2
151.1
153.9
156.3
160.4
164.9
169.8
175.1
178.8
170.7
175.8
181.3
187.2
193.6
198.2
185.2
191.2
197.7
204.6
212.2
217.5
Unit
COP
1.9
2.1
2.3
2.4
2.6
2.7
1.9
2.0
2.2
2.4
2.5
2.6
2.0
2.1
2.3
2.5
2.7
2.9
2.0
2.2
2.3
2.5
2.7
2.9
2.0
2.2
2.4
2.5
2.7
2.9
2.0
2.1
2.3
2.5
2.7
2.8
1.9
2.1
2.3
2.5
2.6
2.8
1.9
2.1
2.3
2.5
2.6
2.7
2.0
2.1
2.3
2.5
2.6
2.7
NOTES:
1. Ratings based on HCFC-22 and sea level altitude.
2. Interpolation is allowed; extrapolation is not permitted. Consult McQuay for performance outside the cataloged ratings.
3. KWi and COP are for the entire unit, including compressors, fan motors and control power.
Catalog ACZ-4
19
% Load
Capacity
Mbh
Power
kWi
EER
IPLV
Unit
Size
% Load
Capacity
Mbh
Power
kWi
EER
IPLV
100
126
8.6
14.6
100
918
65.0
14.1
12.9
53
62
5.2
12.1
76
694
47.8
14.5
065B
14.4
100
170.4
11.6
14.7
50
459
33.0
13.9
013A
13.8
54
85
6.4
13.3
26
235
15.9
14.8
100
217
14.7
14.7
100
984
69.9
14.1
016A
14.3
54
109
7.9
14.0
70
692
47.5
14.6
070B
14.5
100
257
18.5
13.9
47
458
32.2
14.2
020A
14.2
56
132
9.3
14.2
24
234
16.3
14.4
100
337.2
24.1
14.0
100
1047
77.0
13.6
025A
14.2
50
156
11.0
14.2
72
757
54.4
13.9
080B
13.9
100
366
27.1
13.5
50
524
39.0
13.4
028A
13.9
55
187
13.5
13.9
22
233
16.4
14.2
100
456
31.3
14.6
100
1198
84.3
14.2
033A
15.1
55
233
15.3
15.2
76
905
64.0
14.1
090B
14.1
100
569
41.5
13.5
50
599
42.6
14.1
039A
14.8
56
292
19.3
15.1
26
306
22.3
13.7
100
437
30.4
14.4
100
1316
92.8
14.2
76
330
23.2
14.2
73
964
67.6
14.3
030B
13.9
100B
14.2
50
219
15.7
13.9
46
599
42.6
14.1
26
112
8.5
13.1
23
306
22.3
13.7
100
484
33.9
14.3
100
1434
101.3
14.2
73
355
24.5
14.5
75
1082
76.1
14.2
035B
14.1
110B
14.2
45
219
15.7
13.9
50
717
51.1
14.0
23
112
8.5
13.1
25
365
25.9
14.1
100
532
37.4
14.2
100
1587
110.7
14.3
76
403
28.0
14.4
71
1130
82.9
13.6
040B
14.2
120B
14.1
50
266
19.2
13.9
44
691
46.9
14.7
26
137
9.8
14.0
19
306
23.6
13.0
100
619
42.1
14.7
100
1792
128.6
13.9
76
468
31.9
14.7
67
1202
87.4
13.8
045B
14.5
130B
13.7
50
309
21.5
14.4
50
896
64.8
13.8
26
159
11.3
14.0
17
306
23.6
13.0
100
683
48.3
14.1
100
1967
142.3
13.8
73
501
34.3
14.6
70
1378
101.1
13.6
050B
14.4
140B
13.8
45
309
21.5
14.3
46
896
64.8
13.8
23
158
11.3
14.0
19
365
27.2
13.5
100
753
51.5
14.6
100
2143
156.0
13.7
76
569
38.8
14.7
67
1437
104.6
13.7
055B
14.5
155B
13.7
50
376
26.3
14.3
50
1071
78.5
13.6
26
193
13.6
14.2
17
365
27.2
13.5
100
836
58.3
14.3
73
611
41.1
14.9
060B
14.6
45
376
26.3
14.3
23
193
13.6
14.2
NOTE: Certified according to ARI Standard 365-2002. For IPLV calculations, the full load and part load ratings are at 80F
ambient air temperature and 50F suction temperature, with 15 degrees F superheat.
010A
20
Catalog ACZ-4
Sound Data
Table 9, ACZ 010A-155B Sound Pressure, w/o Sound Insulation
ACZ Unit
Model
010A
013A
016A
020A
025A
028A
033A
039A
030B
035B
040B
045B
050B
055B
060B
065B
070B
080B
090B
100B
110B
120B
130B
140B
155B
63
52
52
53
58
58
58
59
61
65
65
65
65
66
66
66
67
68
68
68
67
67
66
66
67
67
125
52
52
54
56
57
58
59
62
64
64
64
64
65
66
66
66
67
68
68
65
66
68
69
68
69
4000
44
44
45
48
48
48
51
53
46
46
46
47
47
47
49
49
49
49
49
54
54
56
56
59
59
8000
42
42
42
48
48
48
50
51
41
41
41
42
42
42
44
44
44
44
44
54
54
55
55
56
56
Overall
A-Weighted
55
55
56
57
58
58
61
63
61
61
61
62
63
63
64
64
65
65
65
66
66
67
67
68
68
8000
69
69
69
75
75
75
77
78
68
68
68
69
69
69
71
71
71
71
71
81
81
82
82
83
83
Overall
A-Weighted
82
82
83
84
85
85
88
90
88
88
88
89
90
90
91
91
92
92
92
93
93
94
94
95
95
63
79
79
80
85
85
85
86
88
92
92
92
92
93
93
93
94
95
95
95
94
94
93
93
94
94
Sound data for units with sound insulation are on the next page.
Catalog ACZ-4
21
Number of Number of
Comp.
Fans
2
2
2
2
2
2
2
2
2
3
2
3
2
3
2
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
4
6
4
6
6
6
6
6
6
6
6
6
8000
41
41
41
42
43
43
43
43
44
43
43
43
43
43
43
43
43
43
43
44
44
44
44
44
44
Overall
A-Weighted
53
53
54
55
56
56
57
58
59
58
58
58
60
60
60
60
60
60
61
61
61
61
61
61
62
Overall
A-Weighted
80
80
81
82
83
83
84
85
86
85
85
85
87
87
87
87
87
87
88
88
88
88
88
88
88
63
52
52
52
52
43
54
54
55
57
57
57
57
58
58
58
58
59
61
61
61
61
63
63
63
63
125
52
52
53
53
54
54
54
55
57
57
57
57
58
58
58
58
58
58
58
59
59
59
59
59
59
Number of Number of
Comp.
Fans
2
2
2
2
2
2
2
2
2
3
2
3
2
3
2
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
4
6
4
6
6
8
6
8
6
8
6
8
22
Catalog ACZ-4
Sound levels can be as important as unit cost and efficiency, and must be addressed before
the start of any development program. Efforts by McQuay Design Engineers to design units
that are sensitive to the sound requirements of the market, combined with inherently quiet
scroll compressors, have paid off.
Background Information
Sound is a vibration in an elastic medium and is essentially a pressure and particle
displacement phenomena. A vibrating body produces compression waves, and as the waves
are emitted from the vibrating body, molecules are ultimately compressed. These values are
transmitted through gas, liquid, solidanything which is elastic or viscous.
The sound data provided in this section is presented with both sound pressure and sound
power levels. Sound power is the total sound energy radiated by a source per unit of time
integrated over the surface through which the sound is radiated. Sound power is a
calculated quantity and cannot be measured directly like sound pressure. Sound power is
not dependent on the surrounding environment or distance from the source, as is sound
pressure.
Sound pressure varies with the distance from the source and is dependent on its
surroundings. For example, a brick wall located 10 feet from a unit will affect the sound
pressure measurements differently than a brick wall at 20 feet. Sound pressure is measured
in decibels (dB), which is a dimensionless ratio (on a logarithmic scale) between measured
sound pressure and a reference sound pressure level.
Catalog ACZ-4
23
Sound pressure can be calculated at any distance from the unit if the sound power is
known.
Lp=Lw-(20 log r) + (10 log Q) - .5
Lp = sound pressure
Lw = sound power
Q = directionality factor
With Q=1, Unit suspended in space (theoretical condition), the equation simplifies to:
Lp = Lw (20)(log r) 0.5
With Q=2, for a unit sitting on a flat roof or ground with no adjacent vertical wall as a
reflective surface, the equation simplifies to:
Lp = Lw (20)(log r) + 2.5
With Q=4 for a unit sitting on a flat roof or ground with one adjacent vertical wall as a
reflective surface, the equation simplifies to:
Lp = Lw (20)(log r) + 5.5
The equations are reduced to table form in Table 13 for various distances and the two
most usual cases of Q type of location.
Table 13, dB Conversion of Sound Power to Pressure for Distance
Distance from Sound
Source
ft. (m)
24
30 (9)
27.1
24.0
50 (15)
31.6
28.5
75 (23)
35.1
32.0
100 (30)
37.6
34.5
150 (46)
41.1
38.0
200 (61)
43.6
40.5
300 (91)
47.6
44.0
Catalog ACZ-4
Catalog ACZ-4
25
0F to 34F
<105F
Standard
Ambient
Yes
>106F
High
Ambient
Yes
<105F
Standard
Ambient
No
>106F
High
Ambient
Yes
BC
BH
BC
BH
Notes:
1. VFD is variable speed, fan control through the MicroTech II controller.
2. FanTrol is fan cycling off discharge pressure.
3. The VFD option automatically includes the factory-installed panel fan and filter set.
26
Catalog ACZ-4
Volts
Minimum
Circuit
Ampacity
(MCA)
Hub (Conduit
Connection)
Field Wire
Quantity
Wire
Gauge
75C
Quantity
Nominal
Size
Recommended
In. (mm)
Maximum
010A
208
230
460
575
45
45
22
18
3
3
3
3
8
8
10
10
1
1
1
1
1.00 (25)
1.00 (25)
1.00 (25)
1.00 (25)
50
50
25
20
50
50
25
20
013A
208
230
460
575
54
54
26
23
3
3
3
3
6
6
10
10
1
1
1
1
1.00 (25)
1.00 (25)
1.00 (25)
1.00 (25)
60
60
30
25
70
70
35
30
208
230
460
575
65
65
34
27
3
3
3
3
6
6
10
10
1
1
1
1
1.00 (25)
1.00 (25)
1.00 (25)
1.00 (25)
80
80
40
30
80
80
45
35
020A
208
230
460
575
79
79
41
33
3
3
3
3
4
4
8
10
1
1
1
1
1.00 (25)
1.00 (25)
1.00 (25)
1.00 (25)
90
90
45
40
100
100
50
40
025A
208
230
460
575
103
103
53
45
3
3
3
3
2
2
6
8
1
1
1
1
1.25 (32)
1.25 (32)
1.00 (25)
1.00 (25)
125
125
60
50
125
125
70
60
028A
208
230
460
575
110
110
58
48
3
3
3
3
2
2
6
8
1
1
1
1
1.25 (32)
1.25 (32)
1.00 (25)
1.00 (25)
125
125
70
60
150
150
80
60
033A
208
230
460
575
127
127
62
58
3
3
3
3
1
1
6
6
1
1
1
1
1.50 (38)
1.50 (38)
1.00 (25)
1.00 (25)
150
150
70
70
175
175
80
70
039A
208
230
460
575
182
182
79
63
3
3
3
3
3/0
3/0
4
6
1
1
1
1
1.50 (38)
1.50 (38)
1.00 (25)
1.00 (25)
225
225
90
80
250
250
100
80
016A
Catalog ACZ-4
27
Table 15, ACZ 030B 065B, Single Point Power Electrical Data
(to 105F Ambient Temperature)
Wire
Gauge
Recommd.
Fuse
Or HACR
Breaker
Size
Max. Fuse
Or HACR
Breaker
Size
3
3
3
3
3
1/0
#1
#4
#4
#6
150
150
90
80
60
150
150
90
80
60
146
143
88
74
58
3
3
3
3
3
1/0
1/0
#3
#4
#6
175
175
100
80
70
175
175
100
90
70
040
208
230
380
460
575
158
150
96
79
64
3
3
3
3
3
2/0
1/0
#3
#4
#6
175
175
110
90
70
175
175
110
90
70
045
208
230
380
460
575
167
167
113
81
70
3
3
3
3
3
2/0
2/0
#2
#4
#4
200
200
125
90
80
200
200
125
90
80
050
208
230
380
460
575
184
184
121
94
78
3
3
3
3
3
3/0
3/0
#1
#3
#4
225
225
125
110
90
225
225
125
110
90
055
208
230
380
460
575
199
199
127
104
86
3
3
3
3
3
3/0
3/0
#1
#2
#3
225
225
150
125
100
225
225
150
125
100
060
208
230
380
460
575
221
214
145
108
96
3
3
3
3
3
4/0
4/0
1/0
#2
#3
250
250
175
125
110
250
250
175
125
110
065
208
230
380
460
575
248
228
156
112
105
3
3
3
3
3
250
4/0
2/0
#2
#2
300
250
175
150
125
300
250
175
150
125
POWER SUPPLY
Minimum
Circuit
Ampacity
(MCA)
Quantity
030
208
230
380
460
575
133
126
80
68
52
035
208
230
380
460
575
ACZ-B
Unit Size
Volts
Field Wire
NOTES:
1. See page 46 for all other Electrical Data notes.
2. Conduit hubs are not provided.
28
Catalog ACZ-4
Table 16, ACZ 070B - 155B 60 Hz, Single Point Electrical Power
(to 105F Ambient Temperature)
Minimum
Circuit
Ampacity
(MCA)
POWER SUPPLY
Field Wire
Recommd. Fuse
Or HACR
Breaker Size
Max. Fuse
Or HACR
Breaker Size
300
300
2/0
#1
#2
350
350
200
150
125
350
350
200
150
125
3
3
3
3
3
350
350
2/0
#1
#2
350
350
200
150
125
350
350
200
150
125
358
358
187
150
125
6
6
3
3
3
4/0
4/0
3/0
1/0
#1
400
400
225
175
150
400
400
225
175
150
100
208
230
380
460
575
380
380
219
171
136
6
6
3
3
3
250
250
250
2/0
1/0
450
450
250
200
150
450
450
250
200
150
110
208
230
380
460
575
414
414
248
188
146
6
6
3
3
3
300
300
250
3/0
1/0
500
500
300
225
175
500
500
300
225
175
120
208
230
380
460
575
463
463
260
199
171
6
6
3
3
3
350
300
300
3/0
2/0
500
500
300
225
175
500
500
300
225
175
130
208
230
380
460
575
528
528
282
220
182
6 - (2)
6 - (2)
3
3
3
300
300
300
4/0
3/0
600
600
300
250
200
600
600
300
250
200
140
208
230
380
460
575
613
613
323
248
198
6 - (2)
6 - (2)
3
3
3
350
350
400
250
3/0
700
700
350
250
225
700
700
350
250
225
155
208
230
380
460
575
613
613
361
273
212
6 - (2)
6 - (2)
6
3
3
350
350
4/0
300
4/0
700
700
400
300
225
700
700
400
300
225
ACZ-B
Unit
Size
Volts
070
208
230
380
460
575
281
281
162
124
109
3
3
3
3
3
080
208
230
380
460
575
301
301
168
130
112
090
208
230
380
460
575
NOTES:
1. See page 46 for all other Electrical Data notes.
2. (2) indicates that two conduits are required.
3. Conduit hubs are not provided.
Catalog ACZ-4
29
Table 17, ACZ 010A 039A Compressor and Condenser Fan Motor Amp Draw
ACZ
Unit
Size
Volts
010A
208
230
460
575
013A
208
230
460
575
016A
208
230
460
575
020A
208
230
460
575
025A
208
230
460
575
028A
208
230
460
575
033A
208
230
460
575
039A
208
230
460
575
Hz.
60
14.8
14.8
7.1
5.8
14.8
14.8
7.1
5.8
5.8
5.8
2.8
2.5
2
2
2
2
23.7
21.4
10.7
11.0
91
91
50
37
91
91
50
37
60
18.6
18.6
9.1
7.4
18.6
18.6
9.1
7.4
5.8
5.8
2.8
2.5
2
2
2
2
23.7
21.4
10.7
11.0
156
156
75
54
156
156
75
54
60
23.7
23.7
12.5
9.1
23.7
23.7
12.5
9.1
5.8
5.8
2.8
2.5
2
2
2
2
23.7
21.4
10.7
11.0
189
189
99
74
189
189
99
74
60
29.9
29.9
15.3
11.6
29.9
29.9
15.3
11.6
5.8
5.8
2.8
2.5
2
2
2
2
23.7
21.4
10.7
11.0
232
232
125
100
232
232
125
100
60
33.6
33.6
16.5
13.7
41
41
21.8
17.3
5.8
5.8
2.8
2.5
3
3
3
3
23.7
21.4
10.7
11.0
278
278
127
100
350
350
158
125
60
41.0
41.0
21.8
17.3
41.0
41.0
21.8
17.3
5.8
5.8
2.8
2.5
3
3
3
3
23.7
21.4
10.7
11.0
350
350
158
125
350
350
158
125
60
48.5
48.5
23.7
21.7
48.5
48.5
23.7
21.7
5.8
5.8
2.8
2.5
3
3
3
3
23.7
21.4
10.7
11.0
425
425
187
148
425
425
187
148
60
73.1
73.1
31.0
24.4
73.1
73.1
31.0
24.4
5.8
5.8
2.8
2.5
3
3
3
3
23.7
21.4
10.7
11.0
505
505
225
180
505
505
225
180
Compressors
No. of
Fan
Mtrs
30
Catalog ACZ-4
Table 18, ACZ 030B - 065B, Compressor And Condenser Fan Motor Amp Draw
Rated Load Amps
ACZ-B
F.L.Amps No. Of
Compressors
Fan
Unit Volts
Fan
Motors
Size
Motors
No. 1 No. 3 No. 5 No. 2 No. 4 No. 6
(Each)
Fan
Motors
(Each)
No.1
Across-The-Line
No. 3 No. 5
No.2
No.4
No. 6
030
208
230
380
460
575
25.7
24.2
14.9
13.4
9.3
25.7
24.2
14.9
13.4
9.3
25.7
24.2
14.9
13.4
9.3
25.7
24.2
14.9
13.4
9.3
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
189
189
112
99
74
189
189
112
99
74
189
189
112
99
74
189
189
112
99
74
035
208
230
380
460
575
25.7
24.2
14.9
13.4
9.3
25.7
24.2
14.9
13.4
9.3
31.8
31.8
18.6
16.0
12.2
31.8
31.8
18.6
16.0
12.2
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
189
189
112
99
74
189
189
112
99
74
232
232
144
125
100
232
232
144
125
100
040
208
230
380
460
575
31.8
29.9
18.6
16.0
12.2
31.8
29.9
18.6
16.0
12.2
31.8
29.9
18.6
16.0
12.2
31.8
29.9
18.6
16.0
12.2
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
232
232
144
125
100
232
232
144
125
100
232
232
144
125
100
232
232
144
125
100
045
208
230
380
460
575
33.8
33.8
22.8
16.5
13.7
33.8
33.8
22.8
16.5
13.7
33.8
33.8
22.8
16.5
13.7
33.8
33.8
22.8
16.5
13.7
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
278
278
151
127
100
278
278
151
127
100
278
278
151
127
100
278
278
151
127
100
050
208
230
380
460
575
33.8
33.8
22.8
16.5
13.7
33.8
33.8
22.8
16.5
13.7
41.4
41.4
26.0
21.8
17.3
41.4
41.4
26.0
21.8
17.3
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
278
278
151
127
100
278
278
151
127
100
350
350
195
158
125
350
350
195
158
125
055
208
230
380
460
575
41.4
41.4
26.0
21.8
17.3
41.4
41.4
26.0
21.8
17.3
41.4
41.4
26.0
21.8
17.3
41.4
41.4
26.0
21.8
17.3
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
350
350
195
158
125
350
350
195
158
125
350
350
195
158
125
350
350
195
158
125
060
208
230
380
460
575
41.0
41.0
26.0
21.8
17.3
41.0
41.0
26.0
21.8
17.3
51.3
48.1
33.8
23.7
21.8
51.3
48.1
33.8
23.7
21.8
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
350
350
195
158
125
350
350
195
158
125
425
425
239
187
148
425
425
239
187
148
065
208
230
380
460
575
52.8
48.1
32.7
23.7
21.8
52.8
48.1
32.7
23.7
21.8
52.8
48.1
32.7
23.7
21.8
52.8
48.1
32.7
23.7
21.8
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
23.3
26.1
20.0
13.0
14.0
425
425
239
187
148
425
425
239
187
148
425
425
239
187
148
425
425
239
187
148
Catalog ACZ-4
31
Table 19, ACZ 070B - 155B, Compressor And Condenser Fan Motor Amp Draw
Rated Load Amps
Locked Rotor Amps
F.L.
Compressors
Compressors
No. Of
ACZ-B
Fan
Amps
Fan
Unit Volts
Across-The-Line
Motors
Fan
Size
No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 Motors Motors (Each)
No.1 No. 3 No. 5 No.2 No.4
(Each)
No. 6
070
208
230
380
460
575
52.8
52.8
32.7
23.7
21.8
52.8
52.8
32.7
23.7
21.8
52.8
52.8
32.7
23.7
21.8
73.1
73.1
38.2
30.1
25.2
7.8
7.8
4.1
3.6
3.0
4
4
4
4
4
31.7
35.6
20.0
17.8
14.0
425
425
239
187
148
425
425
239
187
148
425
425
239
187
148
505
505
280
225
180
080
208
230
380
460
575
52.8
52.8
32.7
23.7
21.8
73.1
73.1
38.2
30.1
25.2
52.8
52.8
32.7
23.7
21.8
73.1
73.1
38.2
30.1
25.2
7.8
7.8
4.1
3.6
3.0
4
4
4
4
4
31.7
35.6
20.0
17.8
14.0
425
425
239
187
148
505
505
280
225
180
425
425
239
187
148
505
505
280
225
180
090
208
230
380
460
575
73.1
73.1
38.2
30.1
25.2
73.1
73.1
38.2
30.1
25.2
73.1
73.1
38.2
30.1
25.2
73.1
73.1
38.2
30.1
25.2
7.8
7.8
4.1
3.6
3.0
6
6
6
6
6
31.7
35.6
20.0
17.8
14.0
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
100
208
230
380
460
575
73.1
73.1
38.2
30.1
25.2
73.1
73.1
38.2
30.1
25.2
83.3
83.3
52.5
39.0
30.0
83.3
83.3
52.5
39.0
30.0
7.8
7.8
4.1
3.6
3.0
6
6
6
6
6
31.7
35.6
20.0
17.8
14.0
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
500
500
305
250
198
110
208
230
380
460
575
86.4
86.4
52.5
39.0
30.0
86.4
86.4
52.5
39.0
30.0
86.4
86.4
52.5
39.0
30.0
86.4
86.4
52.5
39.0
30.0
7.8
7.8
4.1
3.6
3.0
6
6
6
6
6
31.7
35.6
20.0
17.8
14.0
500
500
305
250
198
500
500
305
250
198
500
500
305
250
198
500
500
305
250
198
120
208
230
380
460
575
52.8
52.8
32.7
23.7
21.8
52.8
52.8
32.7
23.7
21.8
52.8
52.8
32.7
23.7
21.8
74.5
74.5
39.8
30.6
25.2
74.5
74.5
39.8
30.6
25.2
74.5
74.5
39.8
30.6
25.2
7.8
7.8
4.1
3.6
3.0
8
8
8
8
8
31.7
35.6
20.0
17.8
14.0
425
425
239
187
148
425
425
239
187
148
425
425
239
187
148
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
130
208
230
380
460
575
74.5
74.5
39.8
30.6
25.2
74.5
74.5
39.8
30.6
25.2
74.5
74.5
39.8
30.6
25.2
74.5
74.5
39.8
30.6
25.2
74.5
74.5
39.8
30.6
25.2
74.5
74.5
39.8
30.6
25.2
7.8
7.8
4.1
3.6
3.0
8
8
8
8
8
31.7
35.6
20.0
17.8
14.0
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
140
208
230
380
460
575
87.9
87.9
39.8
30.6
25.2
87.9
87.9
39.8
30.6
25.2
87.9
87.9
39.8
30.6
25.2
88.0
88.0
52.5
39.0
30.0
88.0
88.0
52.5
39.0
30.0
88.0
88.0
52.5
39.0
30.0
7.8
7.8
4.1
3.6
3.0
8
8
8
8
8
31.7
35.6
20.0
17.8
14.0
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
500
500
305
250
198
500
500
305
250
198
155
208
230
380
460
575
88.0
88.0
52.5
39.0
30.0
88.0
88.0
52.5
39.0
30.0
88.0
88.0
52.5
39.0
30.0
88.0
88.0
52.5
39.0
30.0
88.0
88.0
52.5
39.0
30.0
88.0
88.0
52.5
39.0
30.0
7.8
7.8
4.1
3.6
3.0
8
8
8
8
8
31.7
35.6
20.0
17.8
14.0
500
500
305
250
198
500
500
305
250
198
500
500
305
250
198
500
500
305
250
198
500
500
305
250
198
500
500
305
250
198
32
Catalog ACZ-4
Table 20, ACZ 010A 039A, Field Wiring Data, Single Point Power
Wiring to
Wiring to
Standard Power Block Terminal
Optional Disconnect Switch
Maximum
Connector Wire
Factory Option
Disconnect
Terminal
Range
Connector Wire Range
Size
Amps
(Copper Wire Only)
(Copper Wire Only)
ACZ
UNIT
SIZE
Volts
010A
208
230
460
575
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
100
100
63
63
#8-1/0
#8-1/0
#1-#14
#1-#14
013A
208
230
460
575
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
100
100
63
63
#8-1/0
#8-1/0
#1-#14
#1-#14
016A
208
230
460
575
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
100
100
63
63
#8-1/0
#8-1/0
#1-#14
#1-#14
020A
208
230
460
575
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
100
100
63
63
#10-1/0
#10-1/0
#1-#14
#1-#14
025A
208
230
460
575
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
100
100
#2-4/0
#2-4/0
#8-1/0
#10-1/0
028A
208
230
460
575
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
100
100
#2-4/0
#2-4/0
#8-1/0
#10-1/0
033A
208
230
460
575
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
100
100
#2-4/0
#2-4/0
#8-1/0
#10-1/0
039A
208
230
460
575
335
335
175
175
6 GA 400 kcmil
6 GA 400 kcmil
14 GA 2/0
14 GA 2/0
225
225
125
100
#2-4/0
#2-4/0
#3-3/0
#10-1/0
Catalog ACZ-4
33
Table 21, ACZ 030B 065B, Field Wiring Data, Single Point Power
Wiring to Standard
Power Block
Connector Wire
Terminal
Range
Amps
(Copper Wire Only)
ACZ
Unit
Size
Volts
030B
208
230
380
460
575
175
175
175
175
175
035B
208
230
380
460
575
Wiring to Optional
Non-Fused Disconnect Switch
Disconnect
Size
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
150
150
150
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
150
150
150
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
040B
208
230
380
460
575
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
150
150
150
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
045B
208
230
380
460
575
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
150
150
150
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
050B
208
230
380
460
575
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
150
150
150
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
055B
208
230
380
460
575
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
250
250
150
150
150
#6 - 350 kcmil
#6 - 350 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
# 4 - 300 kcmil
060B
208
230
380
460
575
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
400
400
250
150
150
065B
208
230
380
460
575
380
380
380
175
175
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
400
400
250
150
150
34
Catalog ACZ-4
Table 22, ACZ 070B - 155B, 60 Hz, Field Wiring Data, Single Point
Wiring to Standard
Power Block
Connector Wire
Terminal
Range
Amps
(Copper Wire Only)
ACZ
Unit
Size
Volts
070B
208
230
380
460
575
380
380
380
175
175
080B
208
230
380
460
575
Wiring to Optional
Non-Fused Disconnect Switch
Disconnect
Size
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
400
400
250
250
150
380
380
380
380
175
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
400
400
250
250
150
090B
208
230
380
460
575
760
760
380
380
380
2 GA 500 kcmil
2 GA 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
600
600
250
250
250
100B
208
230
380
460
575
760
760
380
380
380
2 GA 500 kcmil
2 GA 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
600
600
400
250
250
110B
208
230
380
460
575
760
760
380
380
380
2 GA 500 kcmil
2 GA 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
600
600
400
250
250
120B
208
230
380
460
575
760
760
380
380
380
2 GA 500 kcmil
2 GA 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
600
600
400
400
250
130B
208
230
380
460
575
760
760
380
380
380
2 GA 500 kcmil
2 GA 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
800
800
400
400
400
140B
208
230
380
460
575
760
760
380
380
380
2 GA 500 kcmil
2 GA 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
800
800
400
400
400
155B
208
230
380
460
575
760
760
760
380
380
2 GA 500 kcmil
2 GA 500 kcmil
2 GA 500 kcmil
#4 500 kcmil
#4 500 kcmil
800
800
600
400
400
Catalog ACZ-4
35
Table 23, ACZ 030B - 065B, 60 Hz, Multi-Point, Power Electrical Data
(to 105F Ambient Temperature)
Electrical Circuit #1
ACZ
Unit
Size
Electrical Circuit #2
Max.
Recommd
Minimum Power Supply
Fuse
Fuse
Volts Circuit
Field Wire
or HACR or HACR
Ampacity
Breaker
Breaker
Wire
(MCA)
Qty
Size
Size
Gauge
Power
Recommd
Max. Fuse
Minimum
Supply
Fuse
Circuit
Field Wire or HACR or HACR
Breaker
Ampacity
Breaker
Wire
Size
(MCA)
Qty
Size
Gauge
030B
208
230
380
460
575
70
66
42
36
27
3
3
3
3
3
#4
#4
#8
#8
#10
80
80
50
45
35
90
90
50
45
35
70
66
42
36
27
3
3
3
3
3
#4
#4
#8
#8
#10
80
80
50
45
35
90
90
50
45
35
035B
208
230
380
460
575
70
66
42
36
27
3
3
3
3
3
#4
#4
#8
#8
#10
80
80
50
45
35
90
90
50
45
35
83
83
50
42
34
3
3
3
3
3
#4
#4
#8
#8
#10
100
100
60
50
40
110
100
60
50
45
040B
208
230
380
460
575
83
79
50
42
34
3
3
3
3
3
#4
#4
#8
#8
#10
100
100
60
50
40
110
100
60
50
45
83
79
50
42
34
3
3
3
3
3
#4
#4
#8
#8
#10
100
100
60
50
40
110
100
60
50
45
045B
208
230
380
460
575
88
88
60
43
37
3
3
3
3
3
#3
#3
#6
#8
#8
110
110
70
50
45
110
100
80
50
50
88
88
60
43
37
3
3
3
3
3
#3
#3
#6
#8
#8
110
110
70
50
45
110
100
80
50
50
050B
208
230
380
460
575
88
88
60
43
37
3
3
3
3
3
#3
#3
#6
#8
#8
110
110
70
50
45
110
110
80
50
50
105
105
67
55
45
3
3
3
3
3
#2
#2
#4
#6
#8
125
125
80
70
50
125
125
80
70
60
055B
208
230
380
460
575
105
105
67
55
45
3
3
3
3
3
#2
#2
#4
#6
#8
125
125
80
70
50
125
125
80
70
60
105
105
67
55
45
3
3
3
3
3
#2
#2
#4
#6
#8
125
125
80
70
50
125
125
80
70
60
060B
208
230
380
460
575
105
105
67
55
45
3
3
3
3
3
#2
#2
#4
#6
#8
125
125
80
70
50
125
125
80
70
60
130
120
82
59
55
3
3
3
3
3
#1
#1
#3
#6
#6
150
150
100
70
70
175
150
110
80
70
065B
208
230
380
460
575
130
120
82
59
55
3
3
3
3
3
#1
#1
#3
#6
#6
150
150
100
70
70
175
150
110
80
70
130
120
82
59
55
3
3
3
3
3
#1
#1
#3
#6
#6
150
150
100
70
70
175
150
110
80
70
36
Catalog ACZ-4
Table 24, ACZ 070B - 155B, 60 Hz, Multi-Point, Power Electrical Data
(to 105F Ambient Temperature)
Electrical Circuit #1
Electrical Circuit #2
Power
Supply
Field Wire
Power
Supply
Field Wire
Recommd Max.
Minimum
Fuse
Fuse
Circuit
or HACR or HACR
Ampacity
Breaker
Breaker
Wire
(MCA)
Size
Size
Gauge
Max.
Recommd
Fuse
Fuse
or HACR or HACR
Breaker
Breaker
Wire
Qty
Size
Size
Gauge
ACZ
Unit
Size
Volts
070B
208
230
380
460
575
135
135
82
61
55
3
3
3
3
3
1/0
1/0
#4
#6
#6
175
175
100
70
70
175
175
110
80
70
160
160
89
69
59
3
3
3
3
3
2/0
2/0
#3
#4
#6
200
200
110
90
70
225
225
125
100
80
080B
208
230
380
460
575
160
160
89
69
59
3
3
3
3
3
2/0
2/0
#3
#4
#6
200
200
110
90
70
225
225
125
100
80
160
160
89
69
59
3
3
3
3
3
2/0
2/0
#3
#4
#6
200
200
110
90
70
225
225
125
100
80
090B
208
230
380
460
575
188
188
98
79
66
3
3
3
3
3
3/0
3/0
#3
#4
#4
225
225
110
90
80
250
250
125
110
90
188
188
98
79
66
3
3
3
3
3
3/0
3/0
#3
#4
#4
225
225
110
90
80
250
250
125
110
90
100B
208
230
380
460
575
188
188
98
79
66
3
3
3
3
3
3/0
3/0
#3
#4
#4
225
225
110
90
80
250
250
125
110
90
218
218
130
99
77
3
3
3
3
3
4/0
4/0
#1
#3
#4
250
250
150
125
90
300
250
175
125
100
110B
208
230
380
460
575
218
218
130
99
77
3
3
3
3
3
4/0
4/0
#1
#3
#4
250
250
150
125
90
300
250
175
125
100
218
218
130
99
77
3
3
3
3
3
4/0
4/0
#1
#3
#4
250
250
150
125
90
300
250
175
125
100
120B
208
230
380
460
575
203
203
123
92
83
3
3
3
3
3
4/0
3/0
#1
#3
#4
250
225
150
110
100
250
225
150
110
100
273
273
146
114
94
3
3
3
3
3
300
300
1/0
#1
#3
300
300
175
150
110
300
300
200
175
125
130B
208
230
380
460
575
273
273
146
114
94
3
3
3
3
3
300
300
1/0
#1
#3
300
300
175
125
110
300
300
175
125
110
273
273
146
114
94
3
3
3
3
3
300
300
1/0
#1
#3
300
300
175
125
110
300
300
175
125
110
140B
208
230
380
460
575
317
317
146
114
94
3
3
3
3
3
300
300
1/0
#1
#3
400
400
175
125
110
400
400
175
125
110
317
318
187
141
110
3
3
3
3
3
400
400
2/0
1/0
#2
400
400
225
175
125
400
400
225
175
125
155B
208
230
380
460
575
317
318
187
141
110
3
3
3
3
3
400
400
2/0
1/0
#2
400
400
225
175
125
400
400
225
175
125
317
318
187
141
110
3
3
3
3
3
400
400
2/0
1/0
#2
400
400
225
175
125
400
400
225
175
125
Minimum
Circuit
Ampacity
(MCA)
Qty
Catalog ACZ-4
37
Wiring to Optional
Non-Fused Disconnect Switch
Disconnect
Connector Wire Range
Size
(Copper Wire Only)
ACZ
Unit
Size
Volts
Cir #1
Cir #2
Cir #1
Cir #2
Cir #1
Cir #2
Cir #1
Cir #2
030B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
035B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
040B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
045B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
050B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
055B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
060B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
065B
208
230
380
460
575
175
175
175
175
175
175
175
175
175
175
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
14 GA 2/0
150
150
150
150
150
150
150
150
150
150
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
#14 - 1/0
38
Catalog ACZ-4
Wiring to Optional
Non-Fused Disconnect Switch
Disconnect
Connector Wire Range
Size
(Copper Wire Only)
ACZ
Unit
Size
Volts
Cir #1
Cir #2
Cir #1
Cir #2
Cir #1
Cir #2
Cir #1
Cir #2
070B
208
230
380
460
575
380
380
175
175
175
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
150
150
150
225
225
150
150
150
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#14 - 1/0
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#14 - 1/0
080B
208
230
380
460
575
380
380
175
175
175
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
225
225
150
150
150
225
225
150
150
150
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#14 - 1/0
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#14 - 1/0
090B
208
230
380
460
575
380
380
175
175
175
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
250
250
250
150
150
250
250
250
150
150
#4 300 kcmil
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#4 300 kcmil
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
100B
208
230
380
460
575
380
380
175
175
175
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
250
250
250
150
150
250
250
250
150
150
#4 300 kcmil
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#4 300 kcmil
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
110B
208
230
380
460
575
380
380
175
175
175
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
250
250
250
150
150
250
250
250
150
150
#4 300 kcmil
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#4 300 kcmil
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
120B
208
230
380
460
575
380
380
175
175
175
380
380
175
175
175
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
14 GA 2/0
14 GA 2/0
250
250
150
150
150
400
400
250
250
150
#4 300 kcmil
#4 300 kcmil
#14 - 1/0
#14 - 1/0
#14 - 1/0
130B
208
230
380
460
575
380
380
380
380
175
380
380
380
380
175
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
400
400
250
250
150
400
400
250
250
150
140B
208
230
380
460
575
380
380
380
380
175
380
380
380
380
175
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
400
400
250
250
150
400
400
250
250
150
155B
208
230
380
460
575
380
380
380
380
175
380
380
380
380
175
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
#4 500 kcmil
14 GA 2/0
400
400
250
250
150
400
400
250
250
150
Terminal
Amps
Catalog ACZ-4
39
030B
035B
040B
045B
050B
055B
060B
065B
Volts
Minimum
Circuit
Ampacity
(MCA)
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
147
133
80
68
53
158
144
88
74
59
168
155
96
80
64
187
167
113
84
70
207
188
123
94
78
226
207
132
104
86
249
229
147
115
96
270
248
160
124
105
Power Supply
Field Wire
Wire
Quantity
Gauge
75C
3
1/0
3
1/0
3
#4
3
#4
3
#6
3
2/0
3
1/0
3
#3
3
#4
3
#6
3
2/0
3
2/0
3
#3
3
#4
3
#6
3
3/0
3
2/0
3
#2
3
#4
3
#4
3
4/0
3
3/0
3
#1
3
#3
3
#4
3
4/0
3
3/0
3
1/0
3
#2
3
#3
3
250
3
4/0
3
1/0
3
#2
3
#3
3
300
3
250
3
2/0
3
#1
3
#2
Max. Fuse
Or HACR
Breaker
Size
175
150
90
80
60
175
175
100
90
70
200
175
110
90
70
200
200
125
90
80
225
225
125
110
90
225
225
150
125
100
250
250
175
125
110
300
250
175
150
125
NOTES:
1. See page 46 for all Electrical Data notes.
2. Conduit hubs are not provided.
40
Catalog ACZ-4
Table 28, ACZ 030BH 065BH, Compressor & Fan Motor Amps, Single & Multi-Point
ACZ
Unit
Size
No. 3
No. 2
No. 4
208
29.0
29.0
29.0
29.0
230
25.7
25.7
25.7
25.7
030B
380
14.9
14.9
14.9
14.9
460
13.4
13.4
13.4
13.4
575
9.5
9.5
9.5
9.5
208
29.0
29.0
34.0
34.0
230
25.7
25.7
30.9
30.9
035B
380
14.9
14.9
18.6
18.6
460
13.4
13.4
16.2
16.2
575
9.5
9.5
12.2
12.2
208
34.0
34.0
34.0
34.0
230
30.9
30.9
30.9
30.9
040B
380
18.6
18.6
18.6
18.6
460
16.2
16.2
16.2
16.2
575
12.2
12.2
12.2
12.2
208
38.5
38.5
38.5
38.5
230
33.8
33.8
33.8
33.8
045B
380
22.8
22.8
22.8
22.8
460
17.0
17.0
17.0
17.0
575
13.7
13.7
13.7
13.7
208
38.5
38.5
47.6
47.6
230
33.8
33.8
43.3
43.3
050B
380
22.8
22.8
27.2
27.2
460
17.0
17.0
21.8
21.8
575
13.7
13.7
17.3
17.3
208
47.6
47.6
47.6
47.6
230
43.3
43.3
43.3
43.3
055B
380
27.2
27.2
27.2
27.2
460
21.8
21.8
21.8
21.8
575
17.3
17.3
17.3
17.3
208
47.6
47.6
58.1
58.1
230
43.3
43.3
52.8
52.8
060B
380
27.2
27.2
33.8
33.8
460
21.8
21.8
26.5
26.5
575
17.3
17.3
21.8
21.8
208
58.1
58.1
58.1
58.1
230
52.8
52.8
52.8
52.8
065B
380
33.8
33.8
33.8
33.8
460
26.5
26.5
26.5
26.5
575
21.8
21.8
21.8
21.8
NOTE: See page 46 for all Electrical Data notes.
Catalog ACZ-4
Fan
Motors
(Each)
No. Of
Fan
Motors
5.8
5.8
4.1
2.8
3.0
5.8
5.8
4.1
2.8
3.0
5.8
5.8
4.1
2.8
3.0
5.8
5.8
4.1
2.8
3.0
5.8
5.8
4.1
2.8
3.0
5.8
5.8
4.1
2.8
3.0
5.8
5.8
4.1
2.8
3.0
5.8
5.8
4.1
2.8
3.0
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Fan
Motors
(Each)
23.3
26.1
20.0
13.0
14.0
23.3
26.1
20.0
13.0
14.0
23.3
26.1
20.0
13.0
14.0
23.3
26.1
20.0
13.0
14.0
23.3
26.1
20.0
13.0
14.0
23.3
26.1
20.0
13.0
14.0
23.3
26.1
20.0
13.0
14.0
23.3
26.1
20.0
13.0
14.0
No. 3
No. 2
No. 4
189
189
112
99
74
189
189
112
99
74
232
232
144
125
100
278
278
151
127
100
278
278
151
127
100
350
350
195
158
125
350
350
195
158
125
425
425
239
187
148
189
189
112
99
74
189
189
112
99
74
232
232
144
125
100
278
278
151
127
100
278
278
151
127
100
350
350
195
158
125
350
350
195
158
125
425
425
239
187
148
189
189
112
99
74
232
232
144
125
100
232
232
144
125
100
278
278
151
127
100
350
350
195
158
125
350
350
195
158
125
425
425
239
187
148
425
425
239
187
148
189
189
112
99
74
232
232
144
125
100
232
232
144
125
100
278
278
151
127
100
350
350
195
158
125
350
350
195
158
125
425
425
239
187
148
425
425
239
187
148
41
Table 29, ACZ 070BH 155BH, Compressor and Fan Motor Amps, Single and Multi-Point
(Above 105F to 125F)
ACZ
Unit
Size
070B
080B
090B
100B
110B
120B
130B
140B
155B
NOTE:
42
208
58.1
58.1
230
52.8
52.8
380
32.7
32.7
460
25.5
25.5
575
21.8
21.8
208
58.1
78.0
230
52.8
74.1
380
32.7
39.8
460
25.5
37.5
575
21.8
29.9
208
78.0
78.0
230
74.1
74.1
380
39.8
39.8
460
38.8
38.8
575
29.9
29.9
208
78.0
78.0
230
74.1
74.1
380
39.8
39.8
460
38.8
38.8
575
29.9
29.9
208
86.9
86.9
230
83.3
83.3
380
57.6
57.6
460
44.5
44.5
575
32.5
32.5
208
58.1
58.1 58.1
230
52.8
52.8 52.8
380
32.7
32.7 32.7
460
25.5
25.5 25.5
575
21.8
21.8 21.8
208
87.9
87.9 87.9
230
74.2
74.2 74.2
380
43.8
43.8 43.8
460
37.5
37.5 37.5
575
29.9
29.9 29.9
208
87.9
87.9 87.9
230
74.2
74.2 74.2
380
43.8
43.8 43.8
460
37.5
37.5 37.5
575
29.9
29.9 29.9
208
88.0
88.0 88.0
230
88.0
88.0 88.0
380
57.6
57.6 57.6
460
44.5
44.5 44.5
575
32.5
32.5 32.5
See page 46 for all Electrical
No. 4
58.1
78.0
52.8
74.1
32.7
39.8
25.5
37.5
21.8
29.9
58.1
78.0
52.8
74.1
32.7
39.8
25.5
37.5
21.8
29.9
78.0
78.0
74.1
74.1
39.8
39.8
38.8
38.8
29.9
29.9
86.9
86.9
83.3
83.3
57.6
57.6
44.5
44.5
32.5
32.5
86.9
86.9
83.3
83.3
57.6
57.6
44.5
44.5
32.5
32.5
87.9
87.9
74.2
74.2
43.8
43.8
37.5
37.5
29.9
29.9
87.9
87.9
74.2
74.2
43.8
43.8
37.5
37.5
29.9
29.9
88.0
88.0
88.0
88.0
57.6
57.6
44.5
44.5
32.5
32.5
88.0
88.0
88.0
88.0
57.6
57.6
44.5
44.5
32.5
32.5
Data notes.
No.
R.L.Amps
F.L.Amps
of
Fan
Fan
Fan
No. 6 Motors Motors Motors
(Each)
(Each)
No.1
87.9
74.2
43.8
37.5
29.9
87.9
74.2
43.8
37.5
29.9
88.0
88.0
57.6
44.5
32.5
88.0
88.0
57.6
44.5
32.5
425
425
239
187
148
425
425
239
187
148
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
425
425
239
187
148
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
7.8
7.8
4.1
3.6
3.0
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
31.7
35.6
20.0
17.8
14.0
No. 3 No. 5
425
425
239
187
148
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
425
425
239
187
148
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
425
425
239
187
148
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
No.2
No.4
No. 6
425
425
239
187
148
425
425
239
187
148
505
505
280
225
180
500
500
305
250
198
500
500
305
250
198
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
500
500
305
250
198
505
505
280
225
180
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
500
500
305
250
198
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
500
500
305
250
198
505
505
280
225
180
505
505
280
225
180
500
500
305
250
198
500
500
305
250
198
Catalog ACZ-4
030B
035B
040B
045B
050B
055B
060B
065B
Volts
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
Electrical Circuit #1
Electrical Circuit #2
Power Supply
Power Supply
Max. Fuse
Max. Fuse Minimum
Minimum
Field Wire
Field Wire
or HACR
Circuit
or HACR
Circuit
Wire
Wire
Breaker
Breaker Ampacity
Ampacity
Qty Gauge
Qty Gauge
Size
(MCA)
Size
(MCA)
75C
75C
77
3
#4
100
77
3
#4
100
70
3
#4
90
70
3
#4
90
42
3
#8
50
40
3
#8
50
36
3
#8
45
36
3
#8
45
27
3
#10
35
27
3
#10
35
77
3
#4
100
88
3
#3
110
70
3
#4
90
81
3
#4
110
42
3
#8
50
50
3
#8
60
36
3
#8
45
42
3
#8
50
27
3
#10
35
34
3
#10
45
88
3
#3
110
88
3
#3
110
81
3
#4
110
81
3
#4
110
50
3
#8
60
50
3
#8
60
42
3
#8
50
42
3
#8
50
34
3
#10
45
34
3
#10
45
98
3
#3
125
98
3
#3
125
88
3
#3
110
88
3
#3
110
60
3
#6
80
60
3
#6
80
44
3
#8
60
44
3
#8
60
37
3
#8
50
37
3
#8
50
98
3
#3
125
119
3
#1
150
88
3
#3
110
109
3
#2
150
60
3
#6
80
70
3
#4
90
44
3
#8
60
55
3
#6
70
37
3
#8
50
45
3
#8
60
119
3
#1
150
119
3
#1
150
109
3
#2
150
109
3
#2
150
70
3
#4
90
70
3
#4
90
55
3
#6
70
55
3
#6
70
45
3
#8
60
45
3
#8
60
119
3
#1
150
142
3
1/0
200
109
3
#2
150
130
3
#1
175
70
3
#4
90
84
3
#4
110
55
3
#6
70
65
3
#4
90
45
3
#8
60
55
3
#6
70
142
3
1/0
200
142
3
1/0
200
130
3
#1
175
130
3
#1
175
84
3
#4
110
84
3
#4
110
65
3
#4
90
65
3
#4
90
55
3
#6
70
55
3
#6
70
Notes:
1. See page 46 for all Electrical Data notes.
2. Conduit hubs are not supplied.
Catalog ACZ-4
43
Volts
Electrical Circuit #1
Electrical Circuit #2
Power
Power
Supply
Supply
Max. Fuse
Max. Fuse Minimum
Minimum
or HACR
Circuit
or HACR
Circuit
Field Wire
Field Wire
Breaker
Breaker Ampacity
Ampacity
Wire
Wire
Size
(MCA)
Size
(MCA)
Qty Gauge
Qty Gauge
75C
75C
146
3
1/0
200
171
3
2/0
225
134
3
1/0
175
161
3
2/0
225
82
3
#4
110
91
3
#3
125
67
3
#6
90
80
3
#4
110
55
3
#6
70
65
3
#6
90
171
3
2/0
225
171
3
2/0
225
161
3
2/0
225
161
3
2/0
225
91
3
#3
125
91
3
#3
125
80
3
#4
110
80
3
#4
110
65
3
#6
90
65
3
#6
90
199
3
3/0
250
199
3
3/0
250
190
3
3/0
250
190
3
3/0
250
102
3
#2
125
102
3
#2
125
99
3
#3
125
99
3
#3
125
76
3
#4
100
76
3
#4
100
199
3
3/0
250
219
3
4/0
300
190
3
3/0
250
211
3
4/0
250
102
3
#2
125
142
3
1/0
175
99
3
#3
125
111
3
#2
150
76
3
#4
100
83
3
#3
110
219
3
4/0
300
219
3
4/0
300
211
3
4/0
250
211
3
4/0
250
142
3
1/0
175
142
3
1/0
175
111
3
#2
150
111
3
#2
150
83
3
#3
110
83
3
#3
110
220
3
4/0
250
317
3
400
400
203
3
4/0
250
272
3
300
300
123
3
#1
150
159
3
2/0
200
101
3
#2
125
136
3
1/0
175
83
3
#4
100
109
3
#2
125
317
3
400
400
317
3
400
400
272
3
300
300
272
3
300
300
159
3
2/0
200
159
3
2/0
200
136
3
1/0
175
136
3
1/0
175
109
3
#2
125
109
3
#2
125
317
3
400
400
317
3
400
400
272
3
300
300
317
3
400
400
159
3
2/0
200
204
3
4/0
250
136
3
1/0
175
159
3
2/0
200
109
3
#2
125
118
3
#1
150
317
3
400
400
317
3
400
400
317
3
400
400
317
3
400
400
204
3
4/0
250
204
3
4/0
250
159
3
2/0
200
159
3
2/0
200
118
3
#1
150
118
3
#1
150
208
230
070B 380
460
575
208
230
080B 380
460
575
208
230
090B 380
460
575
208
230
100B 380
460
575
208
230
110B 380
460
575
208
230
120B 380
460
575
208
230
130B 380
460
575
208
230
140B 380
460
575
208
230
155B 380
460
575
NOTES:
1.
See page 46 for all Electrical Data notes.
2.
Conduit hubs are not supplied.
44
Catalog ACZ-4
070B
080B
090B
100B
110B
120B
130B
140B
155B
Volts
Minimum
Circuit
Ampacity
(MCA)
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
208
230
380
460
575
303
282
164
138
115
323
304
172
150
123
378
362
194
187
145
398
382
234
200
151
416
401
270
211
157
522
462
273
230
187
612
526
307
263
211
612
571
352
286
219
613
613
393
307
228
Power Supply
Field Wire
Wire
Quantity
Gauge
75C
3
350
3
300
3
2/0
3
1/0
3
#2
3
400
3
350
3
2/0
3
1/0
3
#1
6
250
6
4/0
3
3/0
3
3/0
3
1/0
6
250
6
250
3
250
3
4/0
3
1/0
6
300
6
350
3
300
3
4/0
3
2/0
6
400
6
350
3
300
3
4/0
3
3/0
6 - (2)
350
6 - (2)
300
3
350
3
300
3
4/0
6 - (2)
350
6 - (2)
350
6 - (2)
4/0
3
350
3
4/0
6 - (2)
350
6 - (2)
350
6
250
3
350
3
250
Max. Fuse
Or HACR
Breaker
Size
350
350
200
175
125
400
350
200
175
150
450
400
225
225
175
450
450
250
225
175
500
450
300
250
175
600
500
300
250
200
700
600
350
300
225
700
600
400
300
250
700
700
450
350
250
NOTES:
1. See page 46 for all Electrical Data notes.
2. (2) in column with wire qty. indicates that two conduits are required.
3. Conduit hubs are not supplied.
Catalog ACZ-4
45
Voltage Limitations:
Within 10 percent of nameplate rating
Important: Voltage unbalance not to exceed 2% with a resultant current unbalance of 6 to
10 times the voltage unbalance per NEMA MG-1, 1998 Standard. This is an important
restriction that must be adhered to.
46
Connection Type
Power Block
Std
Std
Disconnect
Swt.
Opt.
Opt.
Circuit
Breakers
Std
Not Avail.
High Short
Circuit Current
Opt
Opt.
Catalog ACZ-4
DISCONNECT
(BY OTHERS)
GND LUG
3 PHASE
TO COMPRESSOR(S)
AND FAN MOTORS
POWER
SUPPLY
FUSED CONTROL
CIRCUIT
TRANSFORMER
120
VAC
DISCONNECT
(BY OTHERS)
TB1-20
TB1
10A
FUSE
120VAC
CONTROL POWER
CONTROL
CIRCUIT
FUSE
(BY OTHERS)
120 VAC
SV1
13
16
120 VAC
SV5
14
HOT GAS BYPASS SOLENOID
120 VAC 1.0 AMP MAX
120 VAC
12
N
17
DX EVAP. FAN PUMP RELAY
(BY OTHERS)
120 VAC 1.0 AMP MAX
ALARM BELL
OPTION
120 VAC
11
ALARM BELL RELAY
17
GND
TIME
CLOCK
AUTO
OFF
TB2
ON
REMOTE STOP
SWITCH
(BY OTHERS)
25
843
35
MANUAL
26
ALARM BELL
RELAY
36
22
COM
NO
BELL
31
33
28
34
Catalog ACZ-4
J5-ID7
J5-ID8
47
DISCONNECT
(BY OTHERS)
GND LUG
3 PHASE
TO COMPRESSOR(S)
POWER
NOTE 1:
ALL FIELD WIRING TO BE
INSTALLED AS NEC CLASS 1
WIRING SYSTEM WITH CONDUCTOR
RATED 600 VOLTS
FUSED CONTROL
CIRCUIT TRANSFORMER
120 VAC
FIELD SUPPLIED
OPTION
DISCONNECT
(BY OTHERS)
TB1-20
10A
FUSE
120VAC
CONTROL POWER
TB1
1
(BY OTHERS)
CONTROL
CIRCUIT
FUSE
120 VAC
35
33
DX EVAP FAN RELAY
(BY OTHERS)
120 VAC 1.0 AMP MAX
ALARM BELL
OPTION
CONTROLLER
120 VAC
34
ALARM BELL RELAY
32
TIME
CLOCK
REMOTE STOP SWITCH
(BY OTHERS)
GND
AUTO OFF
TB2
ON
52
585
72
MANUAL
EVAP FLOW SWITCH
---MANDATORY(BY OTHERS)
IF REMOTE STOP
CONTROL IS USED,
REMOVE LEAD 585
FROM TERM. 52 TO 72.
ALARM BELL
RELAY
43
COM
83
NO
44
NOR. OPEN PUMP AUX.
CONTACTS (OPTIONAL)
61
54
(SEE NOTE 2)
4-20MA FOR
DEMAND LIMIT
(BY OTHERS)
J20-ID18
+
-
70
71
GND
NOTE 2:
EVAP. AIR FLOW SWITCH OR
FAN AUX. CONTACT FOR
CIRCUIT #2 FAN WHEN UNIT IS
SET FOR CIRCUIT SEQUENCING
MODE.
91
93
24 VAC
92
93
24 VAC
95
97
24 VAC
96
97
NOTE 3:
WHEN CONNECTED TO
EVAPORATORS USING
OPTIONAL CIRCUIT CONTROL,
STAGES 1-3 ACTIVATE
COMPRESSORS FOR
CONDENSING UNIT CIRCUIT #1
AND STAGES 4-6 ACTIVATE
COMPRESSORS FOR
CONDENSING UNIT CIRCUIT #2.
STAGE 2
ST
TB3
101
102
103
105
106
STAGE 3
107
1 ST COMPR. - CIRCUIT #2
108
109
110
111
112
STAGE 5
101
102
103
105
106
107
108
109
UNIT
CIRCUIT #1
104
(SEE NOTE 3)
TB3
UNIT
CIRCUIT #2
110
111
112
48
Catalog ACZ-4
Physical Data
ACZ-A
Table 33, Physical Data, ACZ 010A through 020A
ACZ MODEL NUMBER
PHYSICAL DATA
010A
013A
016A
020A
BASIC DATA
Number Of Refrigerant Circuits
22.0 (10.0)
73.6 x 46.3 x
50.8
(1869) x (1176)
x (1289)
1000 (454)
22.0 (10.0)
73.6 x 46.3 x
50.8
(1869) x (1176)
x (1289)
1000 (454)
1080 (490)
1080 (490)
1300 (590)
1420 (645)
220 (99.7)
220 (99.7)
220 (99.7)
220 (99.7)
24.0 (10.9)
31.0 (14.1)
73.6 x 46.3 x
73.6 x 46.3 x
50.8
50.8
(1869) x (1176) (1869) x (1176) x
x (1289)
(1289)
1220 (554)
1340 (608)
COMPRESSORS
Type
Nominal Horsepower
Oil Charge Per Compressor, Oz. (g)
Scroll
Scroll
Scroll
Scroll
4.0 / 4.0
6.0 / 6.0
7.5 / 7.5
9.0 / 9.0
57 (1616)
60 (1701)
140 (3969)
140 (3969)
0 50 100
0 50 100
0 50 100
0 50 100
CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING
Coil Face Area, Sq. Ft. (M2)
Finned Height x Finned Length, In.
Finned Height x Finned Length, (mm)
30.3 (2.8)
30.3 (2.8)
30.3 (2.8)
84 x 52
84 x 52
84 x 52
30.3 (2.8)
84 x 52
(2134) x (1321)
(2134) x (1321)
(2134) x (1321)
(2134) x (1321)
16 x 2
16 x 2
16 x 3
16 x 3
35.3 (16.0)
35.3 (16.0)
50.3 (22.8)
50.3 (22.8)
2 26 (660)
2 26 (660)
2 26 (660)
2 26 (660)
2 1.0 (0.75)
2 1.0 (0.75)
2 1.0 (0.75)
2 1.0 (0.75)
Catalog ACZ-4
1140
1140
1140
1140
13950 (6584)
13950 (6584)
12000 (5664)
12000 (5664)
49
PHYSICAL DATA
025A
028A
033A
039A
BASIC DATA
Number Of Refrigerant Circuits
Unit Operating Charge, R-22, Lb. (kg)
Cabinet Dimensions, LxWxH, In.
Cabinet Dimensions, LxWxH, (mm)
Unit Operating Weight, Lbs. (kg)
34.0 (15.4)
36.0 (16.3)
106.2x 46.3 x
106.2x 46.3 x
50.8
50.8
(2697) x (1176) (2697) x (1176)
x (1289)
x (1289)
1470 (667)
1490 (676)
47.0 (21.3)
106.2x 46.3 x
58.8
(2697) x (1176)
x (1493)
1760 (799)
50.0 (22.7)
106.2x 46.3 x
58.8
(2697) x (1176)
x (1493)
1960 (890)
1580 (717)
1600 (726)
1890 (858)
2090 (949)
350 (159)
350 (159)
435 (197)
435 (197)
COMPRESSORS
Type
Scroll
Scroll
Scroll
Scroll
Nominal Horsepower
10.0 / 13.0
13.0 / 13.0
15.0 / 15.0
20.0 / 20.0
140 (3969)
140 (3969)
140 (3969)
296 (8392)
0 50 100
0 50 100
0 45 - 100
0 50 100
CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING
Coil Face Area, Sq. Ft. (M2)
Finned Height x Finned Length, In.
Finned Height x Finned Length, (mm)
49.0 (4.6)
49.0 (4.6)
58.3 (5.4)
84 x 84
84 x 84
100 x 84
100 x 84
(2545) x (2134)
(2545) x (2134)
58.3 (5.4)
16 x 2
16 x 2
16 x 3
16 x 3
53.1 (24.0)
53.1 (24.0)
90.7 (41.1)
92.8 (42.0)
3 26 (660)
3 26 (660)
3 26 (660)
3 26 (660)
3 1.0 (0.75)
3 1.0 (0.75)
3 1.0 (0.75)
3 1.0 (0.75)
50
1140
1140
1140
1140
20925 (9877)
20925 (9877)
19800 (9346)
19800 (9346)
Catalog ACZ-4
PHYSICAL DATA
030B
BASIC DATA
Ckt.1
035B
Ckt.2
Ckt.1
040B
Ckt.2
Ckt.1
Ckt.2
2
24
24
26
26
29
29
10
10
11
11
13
13
3600 (1634)
3600 (1634)
3600 (1634)
3550 (1612)
3550 (1612)
3550 (1612)
284 (129)
284 (129)
284 (129)
Tandem Scrolls
Tandem Scrolls
Tandem Scrolls
7.5
7.5
7.5
9.0
9.0
140
140
140
140
140
140
(496)
(496)
(496)
(496)
(496)
(496)
9.0
0-25-50-75-100
0-23-50-73-100
0-25-50-75-100
0-25-50-75-100
0-27-50-77-100
0-25-50-75-100
CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING
Coil Face Area, Sq. Ft.
26.3
26.3
26.3
26.3
26.3
2.4
2.4
2.4
2.4
2.4
50x75.6
1270 x
1920
16 x 3
50x75.6
1270 x
1920
16 x 3
50x75.6
1270 x
1920
16 x 3
50x75.6 50x75.6
1270 x 1270 x
1920
1920
16 x 3
16 x 3
50x75.6
1270 x
1920
16 x 3
49 (22)
450
(3103)
49 (22)
450
(3103)
49 (22)
450
(3103)
49 (22)
450
(3103)
49 (22)
450
(3103)
26.3
2.4
49 (22)
450
(3103)
4 30 (762)
4 30 (762)
4 30 (762)
4 1.0
4 1.0
4 1.0
1140
1140
1140
8950 (4224)
8950 (4224)
8950 (4224)
24,316 (11,478)
24,316 (11,478)
24,316 (11,478)
Catalog ACZ-4
51
PHYSICAL DATA
BASIC DATA
045B
Ckt.1
050B
Ckt.2
Ckt.1
055B
Ckt.2
Ckt.1
060B
Ckt.2
Ckt.1
Ckt.2
2
33
33
34
34
36
36
45
45
15
15
15
15
16
16
20
20
94.4 x 88.0 x 100.4 94.4 x 88.0 x 100.4 94.4 x 88.0 x 100.4 94.4 x 88.0 x 100.4
2398 x 2235 x
2398 x 2235 x
2398 x 2235 x
2398 x 2235 x
2250
2250
2250
2250
3610 (1639)
3650 (1657)
3800 (1725)
3850 (1748)
3550 (1612)
3590 (1630)
3730 (1693)
3780 (1716)
288 (130)
288 (130)
476 (130)
476 (130)
Type
Tandem Scrolls
Tandem Scrolls
Tandem Scrolls
Tandem Scrolls
10.0
10.0
13.0
10.0
13.0
13.0
130
15.0
140
140
140
140
140
140
140
140
(496)
(496)
(496)
(496)
(496)
(496)
(496)
(496)
0-25-50-75-100
0-25-50-75-100
0-22-50-72-100
0-28-50-78-100
0-25-50-75-100
0-25-50-75-100
0-23-50-73-100
0-27-50-77-100
CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING
Coil Face Area, sq. ft.
26.3
26.3
44.1
44.1
44.1
44.1
44.1
44.1
2.4
2.4
4.1
4.1
4.1
4.1
4.1
4.1
50x75.6
1270 x
1920
16 x 3
49 (22)
450
(3103)
49 (22)
450
(3103)
60(27)
450
(3103)
60(27)
450
(3103)
60(27)
450
(3103)
42x75.6
1067 x
1920
16 x 2
60(27)
450
(3103)
42x75.6 42x75.6
1067 x 1067 x
1920
1920
16 x 3
16 x 3
82 (37)
450
(3103)
82 (37)
450
(3103)
4 30 (762)
4 30 (762)
4 30 (762)
4 30 (762)
4 1.5
4 1.5
4 1.5
4 1.5
1140
1140
1140
1140
8950 (4224)
8950 (4224)
8950 (4224)
8950 (4224)
39,600 (18,692)
39,600 (18,692)
37,228 (17,572)
37,228 (17,572)
52
Catalog ACZ-4
PHYSICAL DATA
065B
BASIC DATA
Ckt.1
070B
Ckt.2
Ckt.1
080B
Ckt.2
Ckt.1
Ckt.2
2
46
46
52
52
59
59
(21)
(21)
(24)
(24)
(27)
(27)
3820 (1734)
3970 (1802)
4080 (1852)
476 (216)
568 (258)
568 (258)
Type
Tandem Scrolls
Tandem Scrolls
Tandem Scrolls
15.0
15.0
15 / 20
15 / 20
15 / 20
15.0
140
140
140
(496)
(496)
(496)
0-25-50-75-100
0-25-50-75-100
0-23-46-77-100
0-31-46-69-100
0-25-50-75-100
0-25-50-75-100
CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING
Coil Face Area, sq. ft.
44.1
44.1
52.6
52.6
52.6
52.6
4.1
4.1
4.9
4.9
4.9
4.9
42x75.6
1067 x
1920
16 x 3
82 (37
450
(3103)
98 (44
450
(3103)
98 (44
450
(3103)
98 (44
450
(3103)
98 (44
450
(3103)
4 30 (762)
4 30 (762)
4 30 (762)
4 1.5
4 2.0
4 2.0
1140
1140
1140
8950 (4224)
8950 (4224)
8950 (4224)
37,228 (17,572
43,452 (20,510)
43,452 (20,510)
Catalog ACZ-4
53
BASIC DATA
Number Of Refrigerant Circuits
Unit Operating Charge, R-22, lbs.
Unit Operating Charge, R-22, (kg)
Cabinet Dimensions, LxWxH, in.
Cabinet Dimensions, LxWxH, (mm)
Unit Operating Weight, Lbs. (kg)
Unit Shipping Weight, Lbs. (kg)
Add'l Weight If Copper Finned Coils, lbs. (kg)
COMPRESSORS
Type
Tandem Scrolls
Tandem Scrolls
Tandem Scrolls
Nominal tonnage of each Compressor
20.0
20.0
20.0
25.0
25.0
25.0
Number Of Compressors per Circuit
2
2
2
2
2
2
Oil Charge Per Compressor, oz.
148
148
148
200
200
200
Oil Charge Per Compressor, (g)
(525)
(525)
(525)
(709)
(709)
(709)
CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT
Staging, 4 Stages, Circuit #1 in Lead
0-25-50-75-100
0-22-50-72-100
0-25-50-75-100
Staging, 4 Stages, Circuit #2 in Lead
0-25-50-75-100
0-28-50-78-100
0-25-50-75-100
CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING
Coil Face Area, sq. ft.
78.8
78.8
78.8
78.8
78.8
78.8
Coil Face Area, (m2)
7.3
7.3
7.3
7.3
7.3
7.3
Finned Height x Finned Length, in.
50 x113.4 50 x113.4 50 x113.4 50 x113.4 50 x113.4 50 x113.4
1270 x
1270 x
1270 x
1270 x
1270 x
1270 x
Finned Height x Finned Length, (mm)
2880
2880
2880
2880
2880
2880
Fins Per Inch x Rows Deep
16 x 3
16 x 3
16 x 3
16 x 3
16 x 3
16 x 3
Pumpdown Capacity, 90% Full Lbs. (kg)
147 (67) 147 (67) 147 (67) 147 (67) 147 (67) 147 (67)
450
450
450
450
450
450
Maximum Relief Valve Pressure Setting, psig (kPa)
(3103)
(3103)
(3103)
(3103)
(3103)
(3103)
CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE
Number Of Fans - Fan Diameter, in. (mm)
6 30 (762)
6 30 (762)
6 30 (762)
Number Of Motors - HP (kW) (Note 1)
6 2.0
6 2.0
6 2.0
Fan And Motor RPM, 60Hz
1140
1140
1140
60 Hz Fan Tip Speed, FPM (m/sec)
8950 (4224)
8950 (4224)
8950 (4224)
60 Hz Total Unit Airflow, CFM (m3/sec)
65,178 (30,765)
65,178 (30,765)
65,178 (30,765)
NOTE: Except for 380V/60 & 575V/60, HP = 2.0
54
Catalog ACZ-4
120B
BASIC DATA
Ckt.1
Ckt.2
Number Of Refrigerant Circuits
2
Unit Operating Charge, R-22, lbs.
76
86
Unit Operating Charge, R-22, (kg)
(35)
(39)
Cabinet Dimensions, LxWxH, in.
173.1 x 88.0 x 100.4
Cabinet Dimensions, LxWxH, (mm)
4397 x 2235 x 2550
Unit Operating Weight, Lbs. (kg)
6970 (3164
Unit Shipping Weight, Lbs. (kg)
6820 (3096)
Add'l Weight If Copper Finned Coils, lbs. (kg)
1155 (524)
COMPRESSORS
Type
Trio Scrolls
Trio Scrolls
Trio Scrolls
Nominal tonnage of each Compressor
15.0
20.0
20.0
20.0
20.0
25.0
Number Of Compressors per Circuit
3
3
3
3
3
3
Oil Charge Per Compressor, oz.
140
148
148
148
148
200
Oil Charge Per Compressor, (g)
(496)
(525)
(525)
(525)
(525)
(709)
CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT
Staging, 6 Stages, Circuit #1 in Lead
0-14-33-48-67-81-100 0-17-33-50-67-83-100 0-15-33-48-67-81-100
Staging, 6 Stages, Circuit #2 in Lead
0-19-33-52-67-86-100 0-17-33-50-67-83-100 0-19-33-52-67-86-100
CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING
Coil Face Area, sq. ft.
105.3
105.3
105.3
105.3
105.3
105.3
Coil Face Area, (m2)
9.8
9.8
9.8
9.8
9.8
9.8
Finned Height x Finned Length, in.
50 x151.6 50 x151.6 50 x151.6 50 x151.6 50 x151.6 50 x151.6
1270 x
1270 x
1270 x
1270 x
1270 x
1270 x
Finned Height x Finned Length, (mm)
3851
3851
3851
3851
3851
3851
Fins Per Inch x Rows Deep
16 x 3
16 x 3
16 x 3
16 x 3
16 x 3
16 x 3
Pumpdown Capacity, 90% Full Lbs. (kg)
196 (89) 196 (89) 196 (89) 196 (89) 196 (89) 196 (89)
Maximum Relief Valve Pressure Setting, psig
450
450
450
450
450
450
(kPa)
(3103)
(3103)
(3103)
(3103)
(3103)
(3103)
CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE
Number Of Fans - Fan Diameter, in. (mm)
8 30 (762)
8 30 (762)
8 30 (762)
Number Of Motors - HP (kW)
8 2.0
8 2.0
8 2.0
Fan And Motor RPM, 60Hz (Note 1)
1140
1140
1140
60 Hz Fan Tip Speed, FPM (m/sec)
8950 (4224)
8950 (4224)
8950 (4224)
60 Hz Total Unit Airflow, CFM (m3/sec)
86,904 (41,020)
86,904 (41,020)
86,904 (41,020)
155B
Ckt.1
Ckt.2
2
104
104
(47)
(47)
173.1 x 88.0 x 100.4
4397 x 2235 x 2550
7760 (3523)
7640 (3469)
1155 (524)
Trio Scrolls
25.0
25.0
3
3
200
200
(709)
(709)
0-17-33-50-67-83-100
0-17-33-50-67-83-100
105.3
105.3
9.8
9.8
50 x151.6 50 x151.6
1270 x
1270 x
3851
3851
16 x 3
16 x 3
196 (89) 196 (89)
450
450
(3103)
(3103)
8 30 (762)
8 2.0
1140
8950 (4224)
86,904 (41,020)
Catalog ACZ-4
55
Dimensional Data
Figure 14, ACZ 010A through 020A
46.27
(1175.26)
POWER ENTRY
KNOCKOUT
(OTHER SIDE)
POWER
ENTRY
CONTROL PANEL
ACCESS DOORS
CONTROL
ELECTRICAL
KNOCKOUT
51.0
(1295.40)
SUCTION
INLET
ACCESS DOOR
LIQUID
OUTLET
6.0
(152.4)
6.0
(152.4)
21.32
(541.53)
46.23 (1174.24)
6.0
(152.4)
6.0
(152.4)
LIFTING SLOTS
31.11 (790.19)
MOUNTING
HOLES
3.94 (100.08)
M0UNTING HOLES
QTY. 4 01.00 (25.4)
49.06 (1246.12)
73.55 (1868.17)
ACZ
Unit Size
Liquid Conn.
inches (mm)
Suction
Conn
inches (mm)
Optional
Hot Gas
Bypass
010A, 013A
7/8 (22.2)
1 1/8 (28.6)
016A, 020A
7/8 (22.2)
1 5/8 (41.3)
7.55
(191.77)
5/8 (15.8)
28 (711.2)
22 (558.8)
23 (584.2)
5/8 (15.8)
25 (635.0)
21 (553.4)
23 (584.2)
POWER ENTRY
KNOCKOUT
(OTHER SIDE)
POWER
ENTRY
CONTROL PANEL
ACCESS DOORS
CONTROL
ELECTRICAL
KNOCKOUT
SUCTION
INLET
ACCESS DOOR
HOT GAS
BYPASS
LIQUID
OUTLET
X
21.32
(541.53)
49.06 (1246.12)
46.19 (1173.23)
49.06 (1246.12)
105.97 (2691.64)
56
ACZ Unit
Size
A
inches (mm)
Liquid
Conn.
inches (mm)
Suction
Conn
inches (mm)
025A, 028A
51 (1295)
7/8 (22.2)
1 5/8 (41.3)
033A, 039A
59 (1499)
7/8 (22.2)
2 1/8 (53.9)
6.0
(152.4) 6.0
(152.4)
6.0
(152.4)
LIFTING SLOTS
3.94 (100.08)
MOUNTING HOLES
QTY. 6 0 1.00 (25.4)
Optional Hot
Gas Bypass
6.0
(152.4)
Y
31.11 (790.19)
7.55
MOUNTING
(191.77)
HOLES
5/8 (15.8)
35 (889.0)
21 (553.4)
23 (584.2)
7/8 (22.28)
35 (889.0)
25 (635.0)
24 (609.6)
Catalog ACZ-4
13.3 (338)
13.3 (338)
REFRIGERANT CONNECTIONS
SUCTION
LINE #2
SUCTION
LINE #1
HOT GAS
BYPASS #1
HOT GAS
BYPASS #2
LIQUID
LINE #1
25.0
(636)
LIQUID
LINE #2
2.0
(51)
8.9 (226)
51.2 (1301)
CONTROL
PANEL
CONTROL
PANEL
POWER
ENTRY
POINT
0.875
KNOCK OUT
FIELD CONTROL
CONNECTION
100.4
(2550)
SUCTION
CONN.
Y
43.8
(1111)
25.8
(656)
16.7
424)
19.9
(506)
HOT GAS
CONN.
LIQUID
CONN.
19.9
(507)
25.1
(637)
9.1
(231)
14.3 (364)
6.4 (162)
X
DWG. #3305196
88.0 (2335)
94.4 (2397)
NOTE: Hail and wind guards add 20 inches to the width of each side.
Suction Conn.
inches
Liquid
Conn.
inches
Circuit 1
Circuit 2
Optional
HGBP
inches
030
(2) 7/8
1 5/8
1 5/8
035
(2) 7/8
1 5/8
1 5/8
040
(2) 7/8
1 5/8
045
(2) 7/8
050
055
ACZ-B
Unit Size
Shipping
Operating
(2) 7/8
36 (914)
42 (1067)
42 (1067)
3550 (1610)
3600 (1633)
(2) 7/8
36 (914)
42 (1067)
42 (1067)
3550 (1610)
3600 (1633)
1 5/8
(2) 7/8
36 (914)
42 (1067)
42 (1067)
3550 (1610)
3600 (1633)
1 5/8
1 5/8
(2) 7/8
36 (914)
41 (1041)
41 (1041)
3550 (1610)
3610 (1637)
(2) 7/8
1 5/8
1 5/8
(2) 7/8
36 (914)
41 (1041)
41 (1041)
3590 (1628)
3650 (1656)
(2) 7/8
1 5/8
1 5/8
(2) 7/8
36 (914)
42 (1067)
42 (1067)
3730 (1692)
3800 (1724)
060
(2) 7/8
1 5/8
2 1/8
(2) 7/8
35 (889)
42 (1067)
43 (1092)
3780 (1715)
3850 (1746)
065
(2) 7/8
2 1/8
2 1/8
(2) 7/8
35 (889)
42 (1067)
43 (1092)
3820 (1733)
4040 (1833)
070
(2) 7/8
2 1/8
2 5/8
(2) 7/8
35 (889)
43 (1092)
45 (1143)
3970 (1801)
4070 (1846)
080
(2) 7/8
2 5/8
2 5/8
(2) 7/8
36 (914)
44 (1118)
46 (1168)
4080 (1851)
4180 (1896)
Catalog ACZ-4
57
12.4
(315)
COMPRESSORS CIRC #2
12.4 (315)
REFRIGERANT CONNECTIONS
2.0 (51)
SUCTION
LINE #2
53.7
(1365)
SUCTION
LINE #1
HOT GAS
BYPASS #2
47.9
(1218)
40.0
(1017)
34.3
(870)
2.0 (51)
51.3 (1304)
HOT GAS
BYPASS #1
LIQUID
LINE #2
LIQUID
LINE #1
COMPRESSORS CIRC #1
CONTROL
PANEL
POWER
ENTRY
POINT
0.875
KNOCK OUTS
CONTROL
PANEL
FIELD CONTROL
CONNECTION
100.4
(2550)
Y
28.5
(724)
6.4
(162)
28.5
(724)
14.4 (364)
X
Dwg. #3305025-R3
88.0 (2235)
134.7 (3421)
NOTE: Hail and wind guards add 20 inches to the width of each side.
58
Circuit 1
Circuit 2
Optional
Hot Gas
Bypass
inches
(2) 1 1/8
2 5/8
2 5/8
1 1/8
100B
(2) 1 1/8
2 5/8
3 1/8
1 1/8
110B
(2) 1 1/8
3 1/8
3 1/8
1 1/8
ACZ
Unit
Size
Liquid
Conn.
inches
090B
Suction Conn.
inches
Center of Gravity
Inches (mm)
Shipping
Weight
Operating
Weight
44
(1118)
43
(1092)
44
(1118)
46
(1168)
44
(1118)
41
(1041)
58
(1473)
58
(1473)
57
(1448)
5510
(2499)
5670
(2572)
5830
(5830)
5630
(2554)
5790
(2626)
5950
(2699)
Catalog ACZ-4
25.2
(640)
12.4
COMPRESSORS CIRC #2 (315)
REFRIGERANT CONNECTIONS
2.0
(51)
53.73
(1364.7)
48.00
(1319.2)
39.95
(1014.7)
34.22
(869.2)
SUCTION
LINE #2
SUCTION
LINE #1
HOT GAS
BYPASS #2
HOT GAS
BYPASS #1
2.0
(51)
LIQUID
LINE #2
COMPRESSORS CIRC #1
82.4 (2093)
LIQUID
LINE #1
CONTROL
PANEL
CONTROL
PANEL
FIELD CONTROL
CONNECTION
17.6
(447)
100.4
(2550)
9.0
(229)
23.9
(114)
POWER
ENTRY
POINT
0.875
KNOCK OUTS
43.8
(1111)
6.4(1624)
23.9
(114)
88.0 (2235)
14.4 (365)
DWG. #3305026
173.1 (4396)
NOTE: Hail and wind guards add 20 inches to the width of each side.
Suction Conn.
inches
ACZ
Unit
Size
Liquid
Conn.
inches
Circuit 1
Circuit 2
Optional
Hot Gas
Bypass
120B
(2) 1 1/8
2 5/8
3 1/8
130B
(2) 1 1/8
3 1/8
3 1/8
140B
(2) 1 1/8
3 1/8
155B
(2) 1 1/8
3 1/8
Catalog ACZ-4
Shipping
Weight
1 1/8
43 (1092)
46 (1168)
75 (1905)
6820 (3094)
6970 (3162)
1 1/8
44 (1118)
46 (1168)
73 (1854)
7080 (3211)
7230 (3280)
3 1/8
1 1/8
43 (1092)
63 (1600)
73 (1854)
7360 (3338)
7480 (3393)
3 1/8
1 1/8
44 (1118)
40 (1016)
71 (1803)
7640 (3466)
7760 (3520)
Operating
Weight
59
Application Data
Unit Placement
ACZ units are for outdoor applications and
can be mounted either on a roof or at
ground level.
For roof mounted
applications, install the unit on a steel
channel or I-beam frame to support the unit
above the roof.
For ground level
applications, install the unit on a
substantial base that will not settle. Use a
one-piece concrete slab with footings
extended below the frost line. Be sure the
foundation is level within 1/2" (13mm)
over its length and width. The foundation
must be strong enough to support the
weights listed in the Physical Data Tables
beginning on page 49.
4 FT. (1220mm)
CLEARANCE FOR
SERVICE ACCESS
4 FT. (1220)
CLEARANCE FOR
SERVICE ACCESS
SEE TABLE 32
DIMENSION A
Coil Side
A
End Opposite
Controls
Control Panel
End
010A - 039A
4 (1.2)
4 (1.2)
4 (1.2)
030B 080B
4 (1.2)
4 (1.2)
4 (1.2)
090B 155B
6 (1.8)
12
4 (1.2)
4 (1.2)
Clearances
Do not block the flow of air to
and from the condenser coil.
Restricting airflow or allowing
air recirculation will result in a
decrease in unit performance and
efficiency because the unit
discharge pressure is increased.
There must be no obstruction
above the unit that would deflect
discharge air downward where it
could be recirculated back to the
inlet of the condenser coil. The
condenser fans are propeller type
and will not operate with
ductwork.
Install the unit with enough side
clearance for air entrance to the
coil and for servicing. Provide
sufficient service access to the
compressors, electrical control
panel and piping components.
60
AIR
DISCHARGE
AIR
DISCHARGE
AIR FLOW
AIR FLOW
AIR FLOW
AIR
DISCHARGE
AIR FLOW
AIR FLOW
Catalog ACZ-4
Do not allow debris to accumulate near the unit where it could be drawn into the condenser
coil. Keep condenser coils and fan discharge free of snow and other obstructions to permit
adequate airflow for proper operation.
If hail and wind guards are used, care must be taken when considering air flow clearances.
The guards add 20 inches to the width of each side of the unit and essentially increase the
total unit width by that amount. Wall spacing in the following discussions must be taken
from the outside of the guards, i.e. 20 inches from the side of the unit.
General
The clearances required for design-life operation of ACZ air-cooled condensers are
described in the previous section. Occasionally, these clearances cannot be maintained due
to site restrictions such as units being too close together or a fence or wall restricting
airflow, or both.
Fortunately, the McQuay ACZ condensing units have several features that can mitigate the
penalties attributable to restricted airflow.
The condenser section is W shaped, as shown below. This allows inlet air for these
coils to come in from either side. A vertical coil and its adjacent angled coil are
manifolded together to serve one circuit. Every compressor set has its own independent
refrigerant circuit.
Building
Circuit #1
Circuit #2
The following sections discuss the most common situations of condenser air restriction and
give capacity and power adjustment factors for each. Note that in unusually severe
conditions, the MicroTech II controller would adjust the unit operation to remain online
until a less severe condition is reached.
Catalog ACZ-4
61
H
D
4.5 ft.
(1.4m)
3.0 ft.
(0.9m)
2.0
62
4.0
4.5 ft.
(1.4m)
3.0 ft.
(0.9m)
5 ft.
(1.5m)
3.5 ft.
(1.0m)
6 ft.
(1.8m)
4 ft.
(1.2m)
3.0
1.0
5 ft.
(1.5m)
3.5 ft.
(1.0m)
.5
6 ft.
(1.8m)
4 ft.
(1.2m)
ACZ
ACZ
090-155 010-080
2.0
Catalog ACZ-4
3.0
6.0
2.0
4.0
1.0
2.0
Catalog ACZ-4
9
ACZ 090-155 (2.7)
10
(3.0)
11
(3.3)
12
(3.6)
9
ACZ 090-155 (2.7)
10
(3.0)
11
(3.3)
12
(3.6)
7
(2.1)
7.5
(2.2)
8
(2.4)
7
(2.1)
7.5
(2.2)
8
(2.4)
63
4.0
8.0
3.0
6.0
2.0
4.0
1.0
2.0
0
15
(4.6)
16
(4.9)
17
(5.2)
18
(5.5)
0
ACZ 090-155 (0.0)
15
(4.6)
16
(4.9)
17
(5.2)
18
(5.5)
0
(0.0)
11
(3.3)
12
(3.7)
13
(4.0)
14
(4.3)
ACZ 010-080
0
(0.0)
11
(3.3)
12
(3.7)
13
(4.0)
14
(4.3)
ACZ 010-080
64
0
ACZ 090-155 (0.0)
Catalog ACZ-4
ACZ 090-155
4
(1.2)
6
(1.8)
3.5
(1.0)
5
(2.0)
3.0
(0.9)
4
(1.2)
2.5
(0.7)
3
(0.9)
0
Catalog ACZ-4
10
20
30
40
50
65
ACZ
010-080
D=4
(1.4)
D=5
(2.0)
ACZ
010-080
D=4
(1.4)
D=5
(2.0)
ACZ
090-155
D=6
(1.8)
D=8
(2.4)
ACZ
090-155
D=6
(1.8)
D=8
(2.4)
ACZ
ACZ
090-155 010-080
D=10
D=7
(3.1)
(2.1)
66
ACZ
ACZ
090-155 010-080
D=10
D=7
(3.1)
(2.1)
Catalog ACZ-4
Refrigerant Piping
Proper refrigerant piping makes the difference between a reliable or an inefficient
problematic system. The primary concerns related to piping are refrigerant pressure drop, a
solid liquid feed to the expansion valves, continuous oil return and properly sized
refrigerant specialties.
The recommended source for refrigerant piping techniques and sizing is the ASHRAE 2002
Refrigeration Handbook, chapter #2.
Refrigerant specialties including the expansion valves, solenoid valves, filter drier and sight
glasses for use with the remote evaporator applications are supplied and installed by the
installing contractor. The remaining components including pipe, insulation, fittings and
Schrader valves are also provided and piped by the installer. The optional hot gas bypass
valve with solenoid valve can be provided as a field installed or factory installed option. A
holding charge of R22 is provided for the unit. The installer must properly evacuate the
piping system and provide the operating charge of R22.
Although conflicting piping recommendations can be found in different sources, McQuay
offers the following recommendations for these controversial issues.
The use of double risers for vertical gas risers is generally not required and should be used
only as a last resort to maintain the minimum refrigerant flow to carry oil up the vertical
risers. Slightly downsizing the vertical riser is a superior option to providing double risers.
Slope the refrigerant lines 1 per 10 feet of horizontal run in the direction of refrigerant
flow to assist oil return.
Resist using hot gas bypass for applications when operation in ambient temperature below
40 degrees is expected. This recommendation helps to maintain adequate condensing
pressures and liquid refrigerant at the expansion valve when condenser capacities are at
their maximum.
Pressure drops in the refrigerant lines should be maintained at or below the ASHRAE
recommendations and line lengths should be made as short as possible. Exceeding these
recommendations will decrease performance and could impact reliability.
Small traps should be provided at the base of each major vertical gas riser to assist in the
collection of oil. If vertical risers exceed more than 25 feet, install a small trap at the
midpoint and not to exceed more than 20 feet intervals.
Use caution in sizing the liquid line in applications where the evaporator is above the
outdoor section. The weight of the liquid refrigerant in the vertical column will decrease
the pressure at the top of the riser (approximately .5 PSI per foot of vertical rise) allowing
some of the refrigerant to flash to a gas. Adequate refrigerant subcooling is needed at the
outdoor section to prevent large volumes of refrigerant gas at the expansion valve.
It is recommended that the piping systems always extend above the highest component in
the refrigeration system before dropping down to make the final refrigerant connections to
components. This practice will hinder the draining of condensed refrigerant to the lower
component when normal shutdown procedures do not occur (such as a power failure).
NOTE: Do not run refrigerant piping underground.
Operating/Standby Limits
Maximum standby ambient air temperature, 130F (5 5C)
Maximum operating ambient air temperature
Standard Ambient Unit, 105F (40.6C) and below, Models BC
High Ambient Unit, above 105F (40.6C) to 125F 51.7C), Models BH
Catalog ACZ-4
67
Vibration Isolators
Vibration isolators are recommended for all roof-mounted installations or wherever
vibration transmission is a consideration.
The unit should be initially on shims or blocks at the listed free height. When all piping,
wiring, flushing, charging, etc. is completed, the springs are adjusted upward to loosen the
blocks or shims that are then removed.
A rubber anti-skid pad is part of the isolator. Installation of spring isolators requires
flexible piping connections and at least three feet of flexible conduit to avoid straining the
piping and transmitting vibration and noise.
Isolator Installation
The unit should be initially installed on shims or blocks at the listed free height. When all
piping, wiring, flushing, charging, etc. is completed, adjust the springs upward to load them
and to provide clearance to remove the shims or blocks.
Installation of spring isolators requires flexible piping connections and at least three feet of
conduit flex tie-ins. Piping and conduit must be supported independently of the unit.
Bolting: If the chiller base is to be bolted to the isolators, it is recommended that the short
threaded studs usually found on isolators be replaced with eight-inch threaded rod that can
extend through the holes on the top of the base and then be bolted. Washers will be
required. Models ACZ 010 through 039 cannot be bolted to the isolators.
RF
LF
RB
LB
Total
259
259
353
377
498
508
605
712
257
257
360
383
505
515
567
649
243
243
251
288
232
232
304
313
241
241
256
292
235
235
284
286
1000
1000
1220
1340
1470
1490
1760
1960
68
R IB
RIF
Control
Panel
L IB
LIF
Catalog ACZ-4
Table 41, Isolator Loads At Each Mounting Location (With Aluminum Fins)
ACZ-B
Model
AGZ-BM
Model
ACZ 030
AGZ 026
ACZ 035
AGZ 030
ACZ 040
ACZ 045
ACZ 050
ACZ 055
ACZ 060
ACZ 065
AGZ 035
AGZ 040
AGZ 045
AGZ 050
AGZ 055
AGZ 060
ACZ 070
AGZ 065
ACZ 080
AGZ 070
Shipping
Wt
Operating.
Wt
Loc. 1
Loc. 2
Loc. 3
Loc. 4
Total
lbs
3550
3600
1227
901
849
623
3600
72
kg
1608
1631
556
408
385
282
1631
32
lbs
3550
3600
1227
901
849
623
3600
72
kg
1608
1631
556
408
385
282
1631
32
lbs
3550
3600
1227
901
849
623
3600
72
kg
1608
1631
556
408
385
282
1631
32
lbs
3550
3610
1261
872
873
604
3610
72
kg
1608
1635
571
395
395
274
1635
32
lbs
3590
3650
1275
881
883
611
3650
72
kg
1626
1653
578
399
400
277
1653
32
lbs
3730
3800
1295
951
896
658
3800
119
kg
1690
1721
587
431
406
298
1721
54
lbs
3780
3850
1303
1016
860
671
3850
119
kg
1712
1744
590
460
390
304
1744
54
lbs
3820
4040
1367
1066
903
704
4040
142
kg
1730
1830
619
483
409
319
1830
65
lbs
3970
4070
1305
1146
862
757
4070
142
kg
1798
1844
591
519
390
343
1844
65
lbs
4080
4180
1278
1192
885
825
4180
217
kg
1848
1894
579
540
401
374
1894
99
NOTE (1): Additional weight for copper coils is per mounting location.
Table 42, Isolator Loads At Each Mounting Location (With Aluminum Fins)
ACZ
Model
AGZ-BM
Model
ACZ090
AGZ 075
ACZ100
AGZ 085
ACZ110
AGZ 090
ACZ120
AGZ 100
ACZ130
AGZ 110
ACZ140
AGZ 120
ACZ155
AGZ 130
Shipping Operating
Loc 1
Wt.
Wt.
Loc 2
Loc 3
Loc 4
Loc 5
Loc 6
(1)
Addl
for
TOTAL
Copper
Fins
lbs
5510
5630
1649
1166
1649
1166
5630
kg
2496
2550
747
528
747
528
2550
217
99
lbs
5670
5790
1734
1227
1657
1172
5790
217
kg
2569
2623
786
556
751
531
2623
99
lbs
5830
5950
1770
1205
1770
1205
5950
217
kg
2641
2695
802
546
802
546
2695
99
lbs
6820
6970
1323
1188
1053
1265
1135
1006
6970
289
kg
3089
3157
599
538
477
573
514
456
3157
131
lbs
7080
7230
1396
1205
1014
1396
1205
1014
7230
289
kg
lbs
kg
3207
7360
3334
3275
7480
3388
632
1477
669
546
1275
578
459
1073
486
632
1411
639
546
1218
552
459
1026
465
3275
7480
3388
131
289
131
lbs
7640
7760
1555
1293
1032
1555
1293
1032
7760
289
kg
3461
3515
704
586
467
704
586
467
3515
131
NOTE (1): Additional weight for copper coils is per mounting location.
Catalog ACZ-4
69
Optional Features
Controls
Hot Gas Bypass
Hot gas bypass permits unit operation down to 10% of full load capacity. This option
includes a factory-installed hot gas bypass valve, solenoid valve, and manual shutoff valve
for each circuit. Interconnecting piping to an evaporator is field installed.
Alarm Bell
Field installed and wired to the control panel to provide remote indication of unit alarm
condition.
BACnet MS/TP
LONTALK (FTT-10A)
Modbus
BACnet Ethernet
Unit
Vibration Isolators
Spring or neoprene-in-shear vibration isolators are available for field installation to reduce
vibration transmission through the unit base.
70
Catalog ACZ-4
Coated Fins
Copper or aluminum fins coated with ElectroFin baked epoxy protective coating with
5000-hour salt spray resistance (ASTM B117-90).
Sound Reduction
Acoustical blankets are factory-installed on each compressor. They are also available for
retrofit field installation.
Electrical
Multi-Point Electrical Connection (ACZ 030B 155B only)
Provides a power connection to each of the units two electrical circuits.
All ambient temperatures above 105F (40C) with fan VFD (low ambient option)
Catalog ACZ-4
Voltage
208
240
460
600
Current (kA)
120
100
65
35
71
Product Specification
Specifications are available in MSWord format. Contact the local McQuay sales office.
SECTION 15XXX
AIR-COOLED SCROLL COMPRESSOR CONDENSING UNITS
ACZ 010A-ACZ 155B
PART 1 - GENERAL
1.01
SUMMARY
Section includes design, performance criteria, refrigerants, controls, and installation
requirements for air-cooled scroll compressor condensing units.
1.02
REFERENCES
Comply with applicable Standards/Codes of ARI 365-94, ANSI/ASHRAE 15, ETL, cETL,
NEC, and OSHA as adopted by the State.
Units shall meet the efficiency standards of ASHRAE Standard 90.1.
1.03
SUBMITTALS
A.
Submit shop drawings and product data in accordance with the specifications.
B.
2.
3.
4.
1.04
5.
6.
Installation manuals.
QUALITY ASSURANCE
A.
72
B.
Catalog ACZ-4
1.05
Condensing units shall be delivered to the job site assembled and charged with a
holding charge of refrigerant and full oil charge by the manufacturer.
B.
1.06.
Comply with the manufacturer's instructions for rigging and handling equipment.
WARRANTY
The refrigeration equipment manufacturers guarantee shall be for a period of one year from
date of equipment start-up but not more than 18 months from shipment. The guarantee shall
provide for repair or replacement due to failure by material and workmanship that prove
defective within the above period, excluding refrigerant.
1.07
MAINTENANCE
Maintenance of the units shall be the responsibility of the owner and performed in
accordance with the manufacturers instructions.
PART 2--PRODUCTS
2.01
2.02
ACCEPTABLE MANUFACTURERS
A.
McQuay International
B.
(Approved Equal)
UNIT DESCRIPTION
Provide and install as shown on the plans factory-assembled, air-cooled scroll compressor
condensing units in the size and quantity specified. Each unit shall consist of hermetic
tandem or triple scroll compressor sets, air-cooled condenser section, control system and all
components necessary for controlled unit operation when field piped and wired to low side
equipment specified elsewhere.
2.03
DESIGN REQUIREMENTS
A.
B.
Performance: Refer to the schedule of performance on the drawings. The unit shall
be capable of stable operation to a minimum of 50 percent of full load without hot
gas bypass. Performance shall be in accordance with ARI Standard 365-94.
C.
Acoustics: Sound pressure levels for the unit shall not exceed the following
specified levels. The manufacturer shall provide the necessary sound treatment to
meet these levels if required. Sound data shall be provided with the quotation. Test
shall be in accordance with ARI Standard 370.
Catalog ACZ-4
73
Octave Band
63
____
125
____
250
____
500
____
1000
____
2000
____
4000
____
8000
____
dBA
____
Condenser: The condenser coils shall consist of 3/8 inch (10mm) seamless copper
tubes mechanically bonded into plate-type fins. The fins shall have full drawn
collars to completely cover the tubes. A subcooling coil shall be an integral part of
the main condenser coil. Condenser fans shall be propeller type arranged for
vertical air discharge and individually driven by direct-drive fan motors. They shall
be equipped with a heavy-gauge fan guard. Fan motors shall be TEAO, threephase, direct-drive, 1140 rpm.
D.
E.
Control System: A centrally located weatherproof control panel shall contain the
field power connection points, control interlock terminals, and control system.
Power and starting components shall include factory short circuit protection of fan
motors and control circuit, individual contactors for each fan motor, solid-state
compressor three-phase motor overload protection, inherent fan motor overload
protection and unit power connections for connection to remote disconnect switch.
Hinged access doors shall be tool-lockable. Barrier panels or separate doors are
required to protect against accidental contact with line voltage when accessing the
control system.
F.
74
Catalog ACZ-4
Shutdown Alarms
Low evaporator pressure
High condenser pressure
Motor protection system
Phase voltage protection (Optional)
Outside ambient temperature
Sensor failures
Limit Alarms
Condenser pressure stage down, unloads at high discharge pressures
Low ambient lockout, shuts off unit at low ambient temperatures
Low evaporator pressure hold, holds stage #1 until pressure rises
Low evaporator pressure unload, shuts off one compressor
Unit Enable Selection
Enables unit operation from either local keypad, digital input, or BAS
Unit Mode Selection
Selects standard cooling or test operation mode
Digital Inputs
Unit off switch
Remote start/stop
Motor protection
Digital Outputs
Shutdown alarm; field wired, activates on an alarm condition, off
when alarm is cleared
Condenser fan control
The unit controller shall provide control of condenser fans based on
compressor discharge pressure.
Building Automation System (BAS) Interface
Factory mounted DDC controller(s) shall support operation on a
BACnet, Modbus or LONMARKS network via one of the data
link / physical layers listed below as specified by the successful
Building Automation System (BAS) supplier.
Catalog ACZ-4
75
Aluminum fins pre-coated with a phenolic epoxy coating with 1000 hour salt spray
rating (ASTM B117-90
ElectroFin baked epoxy coating providing 3000+ hour salt spray resistance (ASTM
B117-90) and is applied to both the coil and the coil frames.
PART 3 - EXECUTION
3.01
INSTALLATION
A.
3.02
B.
C.
E.
Provide all appurtenances required for a fully operational and functional unit.
START-UP
A.
B.
Provide testing and starting of machine, and instruct the Owner in its proper
operation and maintenance.
76
Catalog ACZ-4
Catalog ACZ-4
77
78
Catalog ACZ-4
Catalog ACZ-4
79
This document contains the most current product information as of this printing. For the most up-todate product information, please go to www.mcquay.com.