CIAL Golf Course 1

Location: India / Kochi Grid voltage: 3~240 V

6251 x BP Solar BP 3160N (PV array 1)


Azimuth angle: 0, Inclination: 17, Mounting type: Free installation, PV peak power: 1.00 MWp

133 x STP 8000TL-20 Technical data


Total number of PV modules: PV peak power: Number of inverters: Nominal AC power: AC active power: Active power ratio: Annual energy yield (approx.)*: 6251 1.00 MWp 133 1.06 MW 1.06 MW 106.4 % 1571.04 MWh Energy usability factor: Performance ratio (approx.)*: Spec. energy yield (approx.)*: Line losses (in % of PV energy): Unbalanced load: Self-consumption: Self-consumption quota: 100 % 84.9 % 1571 kWh/kWp 0.61 % 0.00 kVA ----Sunny Design 2.30.0.R

Signature
*Important: The yield values displayed are estimates. They are determined mathematically. SMA Solar Technology AG accepts no responsibility for the real yield value which can deviate from the yield values displayed here. Reasons for deviations are various outside conditions, such as soiling of the PV Modules or fluctuations in the efficiency of the PV modules.

1/2

Evaluation of design
Project name: CIAL Golf Course Project number: 1 Project file: Part project 1 Location: India / Kochi Ambient temperature: Record Low Temperature: 7.00 C Average High Temperature: 31.00 C Record High Temperature: 33.00 C

133 x STP 8000TL-20


PV peak power: Total number of PV modules: Number of inverters: Max. DC power (cos = 1): Max. AC active power (cos = 1): Grid voltage: Nominal power ratio: Displacement power factor cos : 1.00 MWp 6251 133 8.20 kW 8.00 kW 240 V 109 % 1 STP 8000TL-20

Technical data
Input A: PV array 1 36 x BP Solar BP 3160N, Azimuth angle: 0, Inclination: 17, Mounting type: Free installation Input B: PV array 1 11 x BP Solar BP 3160N, Azimuth angle: 0, Inclination: 17, Mounting type: Free installation Input A: Number of strings: PV modules per string: Peak power (input): Typical PV voltage: Min. PV voltage: Min. DC voltage (Grid voltage 240 V): Max. PV voltage: Max. DC voltage (PV): Max. current of PV array: Max. DC current: Input B:

2 18 5.76 kWp 569 V 552 V 150 V 848 V 1000 V 9.1 A 15.0 A

1 11 1.76 kWp 348 V 337 V 150 V 518 V 1000 V 4.6 A 10.0 A

PV/Inverter compatible

Sunny Design 2.30.0.R