Beruflich Dokumente
Kultur Dokumente
Features
Detects earliest onset of an earthquake before damaging shaking occurs. Provides warning. 1-40 seconds of
Eliminates false triggers from environmental vibrations , and filters smaller non-damaging quakes: redundant dual sensors. advanced DSP (digital signal processing) algorithms. Triggers audible alert when an earthquake has been detected. Automatically controls systems through 1 to 32 contact closures, expandable serial control bus, and Ethernet. Supports remote monitoring, diagnostics, and configuration through network interface. Integrates with: building automation standards such as BacNet, LonNet, SCADA, PLC, MODBUS, FIELDBUS, CAN, ISA, and DeviceNet. security systems. communications systems: voice and data.
Earthquake Intelligence ?
SWS.DS.02.05
QuakeGuard
2 Sensors: accelerometers
Control outputs:
! Relay contact closures ! 8 banks of 4 outputs
Detector
I/O Processor
Communications Processor Embedded O/S; DSP Software; Network Utilities; Diagnostics TCP/IP Serial Bus
! Wired or wireless
Network Info: ! Paging
! Cell phone ! Email
Device control
QuakeGuard Applications
Warn personnel: Protect lives and prevent injury. Avoid glass and falling objects, duck and cover. Isolate hazards: Shut off gas and water main valves to prevent fire and water damage. Activate and lock /unlock electronic doors to protect assets and people. Isolate chemicals, gases, and fuel tanks. Prevent accidents in operating rooms. Shut down industrial processes. Protect transportation systems. Protect mission-critical systems and avoid disruption of service: Open critical doors which could become inoperable through building deformation, such as opening fire station doors so rescue trucks can get out. Activate emergency power generation. Secure equipment. Arrest elevators, open doors, and lock in place. Protect assets: Prevent damage to supplies, inventory, engines, machines and other capital equipment. Protect fuel and water supplies.
Specifications
Enclosure NEMA 12 and 4 (main unit) NEMA 4X (sensors) Temperature Storage -30 to 70 C Operating 0 to 50 C Humidity 10% - 90% non-condensing Power 95-235VAC 50-60Hz 150W max (5W typical) Line-level Audio Output 2 channels Transformer-coupled +4dBm into 600 ohms, +4dBu, +1.6dBV Speaker Output 2 channels Class-D amplifier, 5% distortion max 9W / channel into 8 ohms, 12W / channel into 4 ohms Volume digitally controlled (remote access) Relay Output Form C contacts Lifetime: >200,000 operations Ratings, resistive load: 30VDC @ 10A, 110VDC@ 0.5A, 120VAC @ 10A, 240VAC @ 7.5A Ratings, inductive load: 30VDC @ 7A, 110VDC@ 0.3A, 120VAC @ 7A, 240VAC @ 5A Ethernet I/O 10/100 Base-T IEEE 802.3u compatible with UTP, category 5 or better cabling RJ-45 modular jack Test/Reset Input Contact closure 3VDC open-circuit, 3mA shortcircuit, diode protected Battery Configuration One 7.2AH battery, 24 hour min Built-in charger Automatic switch-over when AC fails
Patented Technology
Seismic Warnings P-wave technology is unique in eliminating false positives: filtering both man-made vibrations and small earthquakes (which should be ignored) while triggering on large quakes. Patented DSP algorithms used in QuakeGuard isolate the signature waveforms of a seismic event that has just occurred. Redundant sensors help eliminate false positives. Seismic Warning has received patents covering the use of multiple sensors, technology to eliminate false positives, advanced sensor design and several digital signal analysis techniques, with corresponding international patents pending.
Seismic Warning Systems, Inc. 5619 Scotts Valley Drive, Suite 180, Scotts Valley, CA 95066 Tel: 831 440 1122 Fax: 831 440 1131 www.seismicwarning.com