The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright Nokia Siemens Networks 2011. All rights reserved.
.
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 FlexiPacket MultiRadio installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installing the antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installing the FlexiPacket MultiRadio . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 FlexiPacket MultiRadio installation on already installed FlexiHopper antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Indoor Power Injector installation. . . Installation in the rack . . . . . . . . . . . External connections . . . . . . . . . . . . Indoor Power Injector grounding . . . Power Supply connection . . . . . . . . IDU CABLE connection . . . . . . . . . . ODU CABLE connection . . . . . . . . . ALMs Connector . . . . . . . . . . . . . . . ...... ...... ...... ...... ...... ...... ...... ...... ....... ....... ....... ....... ....... ....... ....... ....... ...... ...... ...... ...... ...... ...... ...... ...... ....... ....... ....... ....... ....... ....... ....... ....... . . . . . . . . 13 13 13 14 14 14 15 15 17 18 19 19 20 21 22
Table of Contents
This document has 25 pages. 1 2 2.1 2.2 2.3 3 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 5 5.1 5.2 5.3 5.4 5.5 5.6 6
Outdoor Power Injector installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outdoor Power Injector grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supplyconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDU CABLE connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ODU CABLE connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
List of Figures
Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16
FH Adapter detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 FH Adapter installed on the FlexiPacket MultiRadio . . . . . . . . . . . . . . . . 12 Indoor Power Injector (Indoor 4 ports) . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Indoor Power Injector connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 PS connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 IDU CABLE connector front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ODU CABLE connector front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 ALMs connector front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Power Injector connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Outdoor Power Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Outdoor Power Injector connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Outdoor Power Injector grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 PS connector inside the Outdoor Power Injector . . . . . . . . . . . . . . . . . . 20 Power cable installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 IDU CABLE connector front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 ODU CABLE connector front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
.
PS connector pin function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDU CABLE connector pin function . . . . . . . . . . . . . . . . . . . . . . . . . . . . ODU CABLE connector pin function . . . . . . . . . . . . . . . . . . . . . . . . . . . ALMs connector pin function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS connector pin function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDU CABLE connector pin function . . . . . . . . . . . . . . . . . . . . . . . . . . . . ODU CABLE connector pin function . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 14 15 16 21 22 23
List of Tables
Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7
Overview
1 Overview
FlexiPacket MultiRadio is compatible with the XD antennas.
For the compatibility with the FlexiHopper antennas a special adapter (to be installed on the FlexiPacket MultiRadio) is available. The FlexiPacket Radio is connected to the Indoor Device by using: 2 cables (1 cable for the Ethernet interface to be connected to the Ethernet connector and 1 cable for the Power Supply to be connected to the PS connector). 1 cable only to be connected to the Ethernet connector, if the Power+Ethernet solution has been used. In this case the Power Injector must be installed (refer to Chapter 4 for the Indoor Power Injector and to Chapter 5 for the Outdoor Power Injector).
t t t
For the information regarding the connectors, the cable termination, the grounding, the tools to be used and the cable fixing refer to the "HW Install" document. This Quick Reference Guide gives the information to install the 1+0 configuration with the integrated antenna. For the other configurations refer to the "HW Install" document. To install the Ethernet Repeater (if required), refer to the "HW Install" document.
.
M10 hex nut
2.2
M10 largewasher
Vertical adjustment
Horizontal adjustment
Horizontal adjustment Antenna mounted on the pole mount (offset left) Vertical adjustment Tighten to 20 Nm Vertical locking screws
Remove tape
2.3
Guide/pin hole
10
Never peel off or damage the foil covering the waveguide opening of the outdoor unit. This may result in equipment failure over time if moisture or particles get inside the unit.
Follow local requirements for earthing (grounding). The principles and requirements vary in different countries.
11
Figure 1
FH Adapter detail
Fix the FH Adapter on the FlexiPacket MultiRadio as shown in Figure 2 by using the 4 screws provided with the adapter.
Figure 2
12
Figure 3
4.1
4.2
External connections
The second Power Source can be used to provide Power Supply redundancy. To semplify in Figure 4 only one port is shown, but the Indoor Power Injector can be used with up to four ports.
Figure 4
13
t
4.3
Insert a 6 A breaker for four ports (1.5 A each used port) between the negative pole of the battery and the Indoor Power Injector.
4.4
Figure 5
PS connector
Signal name 48 V + (Left side pin) 48 V - (Right side pin) Table 1 PS connector pin function
4.5
IDU CABLE connector front view Pair TP3+ TP3TP2+ TP1+ TP1TP2Cable colour white/green green white/orange blue white/blue orange Function Bi-directional pair 3+ Bi-directional pair 3 Bi-directional pair 2+ Bi-directional pair 1+ Bi-directional pair 1Bi-directional pair 2-
14
.
Pair TP4+ TP4Cable colour white/brown brown
Pin # 7 8 Table 2
4.6
Figure 7 Pin #
ODU CABLE connector front view Pair Cable colour Ethernet Function Power function Amphenol Pin on FlexiPacket MultiRadio 7 3 5 1 4 2 6 8
1 2 3 4 5 6 7 8 Table 3
Bi-directional pair 3+ Bi-directional pair 3Bi-directional pair 2+ Bi-directional pair 1+ Bi-directional pair 1Bi-directional pair 2Bi-directional pair 4+ Bi-directional pair 4-
4.7
ALMs Connector
The Indoor Power Injector has a standard RJ45 connector on the front panel for Alarms reporting. The RJ-45 connector is provided with the Indoor Power Injector. Use the same cable use also for the IDU-ODU connection.
15
ALMs connector front view Ethernet Function Short circuit on ODU 1 power supply Short circuit on ODU 2 power supply Short circuit on ODU 3 power supply Short circuit on ODU 4 power supply ALMs connector pin function
16
Figure 9
Insert a 3 A breaker between the negative pole of the battery and the Power Injector.
17
Figure 10
5.1
Installation
The Outdoor Power Injector can be installed on the wall or on the pole. For the details refer to Chapter 8 of the HW Install document.
18
5.2
External connections
Figure 11
5.3
Figure 12
19
5.4
Power Supplyconnection
Figure 13
20
Signal name 48 V + (Left side pin) 48 V - (Right side pin) Table 5 PS connector pin function
Fix the two wires to the positive and the negative poles of the power supply connector inside the Outdoor Power Injector using a screwdriver.
Figure 14
5.5
21
IDU CABLE connector front view Pair TP3+ TP3TP2+ TP1+ TP1TP2TP4+ TP4Cable colour white/green green white/orange blue white/blue orange white/brown brown Function Bi-directional pair 3+ Bi-directional pair 3 Bi-directional pair 2+ Bi-directional pair 1+ Bi-directional pair 1Bi-directional pair 2Bi-directional pair 4+ Bi-directional pair 4-
5.6
22
Figure 16 Pin #
ODU CABLE connector front view Cable colour Ethernet Function Power function Amphenol Pin on FlexiPacket MultiRadio 7 3 5 1 4 2 6 8
Pair
1 2 3 4 5 6 7 8 Table 7
Bi-directional pair 3+ Bi-directional pair 3Bi-directional pair 2+ Bi-directional pair 1+ Bi-directional pair 1Bi-directional pair 2Bi-directional pair 4+ Bi-directional pair 4-
23
.
The LCT is needed for setting the radio parameters.
Check that Automatic Tx Power Control setting is OFF at both ends of the hop when performing fine alignment. Before fine alignment can be done, set the correct frequency and transmit power for both near-end and far-end radios. The FlexiPacket MultiRadio at the other end of the hop must be pre-aligned to this station and must be sending a signal on the correct frequency.
Note that the antenna radiation pattern includes two or more side lobes and one main lobe. The radio needs to be aligned towards the main lobe of the far-end radio. To be sure that you have found the main lobe you also need to detect the side lobes around the main lobe.
Check the DC voltage meter readings: 1. Connect the DC voltage meter (connector type BNC) to the AGC connector. 2. Find the minimum value for the AGC voltage by vertical and horizontal adjustments. The smaller the voltage - the greater the received power.
24
3. Check with the LCT that the Rx power level is within 3 dB of the value stated in the network plan.
25